ML19209D076

From kanterella
Jump to navigation Jump to search
Forwards LER 79-019/03L-0
ML19209D076
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 10/09/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19209D077 List:
References
NJK-79-364, NUDOCS 7910190367
Download: ML19209D076 (1)


Text

- . - - - -.--w _.

' C -

Commonwealth Edison Quad Cities Nuclear Power Station ULY [ M 22710 206 Avenue North Corcova. litinois 61242 Telephone 309/654-2241 NJK 79-364 October 9, 1979 J. Keppler, Regional Director Office of Inspection and Enforcement Region til U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 50-265, DPR-30, Unit 2 Appendix A, Sections 3.2.E.2 and 6.6.B.2.b Enclosed please find Reportable Occurrence Report No. R0 79-19/03L for Quad-Cities Nuclear Power Station. This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B.2.b as a condition leading to operating in a degraded mode permitted by a limiting condition for operation.

Very truly yours, COMMONWEALTH EDIS0N COMPANY QUAD-CITIES NUCLEAR POWER STATION

/

f! WWA N. J. Kalivianakis Station Superintendent NJK/LFG/cmd cc: R. F. Janecek 1175 218 79101903(o1 Y

_ _W O S-00T 0 0 ht \

.(

- -_