05000317/LER-1979-023-03, /03L-0 on 790712:while Withdrawing Group 1 Control Element Assembly,Position Indication for Assembly 65 Stopped Indicating Outward Motion at 42 Inches.Caused by Electronic Failure of Printed Circuit Board.Board Replaced

From kanterella
(Redirected from ML19207A510)
Jump to navigation Jump to search
/03L-0 on 790712:while Withdrawing Group 1 Control Element Assembly,Position Indication for Assembly 65 Stopped Indicating Outward Motion at 42 Inches.Caused by Electronic Failure of Printed Circuit Board.Board Replaced
ML19207A510
Person / Time
Site: Calvert Cliffs 
Issue date: 08/10/1979
From: Lagiewski J
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19207A508 List:
References
LER-79-023-03L-01, LER-79-23-3L-1, NUDOCS 7908200333
Download: ML19207A510 (8)


LER-1979-023, /03L-0 on 790712:while Withdrawing Group 1 Control Element Assembly,Position Indication for Assembly 65 Stopped Indicating Outward Motion at 42 Inches.Caused by Electronic Failure of Printed Circuit Board.Board Replaced
Event date:
Report date:
3171979023R03 - NRC Website

text

(7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

l Ml O ClClN ll@l0101-l0101010101 10 Ol@l41111lilll@l l

l@

o i

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T

$$Rc l L }@l 01 5 l 010 l 0 l 3 l 1 7l@l017l1l2l7 9l@l0l8l1l0l7 9l@

o 1

7 8

60 61 DOCKET NUMBER 68 69 EVENT DATE 14 75 REPORT D ATE 80 EVENT DESCRIPTION AND PROBA8LE CONSEQUENCES h l o 12 I 1 At 4:30 o.m. whib withdrawino Grouo 1 CEA's durino cost refueling starton I

o a i testing program, the primary position indication for CEA 65 stonced indicatino 1

l outward motion at 42".

The secondary (or reedswitch) nosition indication i

o 4

I continued to function nomally. Group 1 was fully withdrawn in accordance with I

O s

o e

I Technical Specification 3.1.3.3.b.3.e.

DiiTl I I

o 8

l C DE CODE SUBCO E COMPONENT CODE SUSCODE SU E

l II E l@ [E_j@ l A l@ l Il Nl Sl T Rl Ul@ l Xl@ W @

o 9

7 8

9 10 11 12 13 18 19 20 SE OU E NTI AL OCCUR R E NCE REPORT REVISION LE n EVENTYEAR REPORT NO.

CODE TYPE NO.

@,ae g'RO 7 19 l l-l 10 12 l 3 l jf_j l 0131 Ll l-l l 01 RT 21 22 23 24 26 27 28 29 30 31 32 KEN A ON ON LA T MET HOURS 22 S 8 IT FOR 8.

SUPPLI MANUr C RER l A lglJ4Z lg

[ Z [g

[ Z l@

l0 l0 0 lY l lN [g lN lg lN l@

lW 1l2l0l@

3J 35 36 37 40 41 42 43 44 47 3

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS l The plant computer did not output position indication for CEA 6_5 due to electronic l

i O

ii ii i i failure of a PC board 2EPl in y-canel location 00F12. Af';er reolacement oT the t

j failed board, the computer recognized CEA 65 selection anf updated position indicationi s l nomally. This failure is not a repetitive occurrence.

l i

3 i

4 1

1 7

8 9 80 STA

% POWER OTHER STATUS DIS O RY DISCOVERY DESCRIPTION Ii I5 I l B l@ l 0l 0l 0l@l NA l

l Al@l Operator Observation l

ACTIVITY CO TENT RELE ASED OF RE LE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE lZl@lZlgl NA l

l NA l

i s

PERSONNEL E XPOS ES NUMRE R TYPE DE SCRIP TION l 0 ] 0 l 0 l@l Z l@l NA

[

i 7

2 i3 80 PERSosNE t,Nau'R,,,

NUVRER

DESCRIPTION

l0l0l0l@l NA i

a 7

8 9 11 i2 80 mi"' " "C ^&'N ' " " @

7 9082 o o TW5 gg NA l

i,

80 a 9 io

,ssEll@l'""'E'SCRiPTiON @

p,! -

NRC USE ONLY

~.,

I NA l

lllllllllllll:

o 7

8 9 to 68 69 80 ;

N AYE OF PREP ARE9 PHONE