ML19099A097
| ML19099A097 | |
| Person / Time | |
|---|---|
| Site: | 07000371 |
| Issue date: | 03/01/2018 |
| From: | Cabrera Services |
| To: | NRC Region 1 |
| Shared Package | |
| ml051740240 | List:
|
| References | |
| Download: ML19099A097 (2) | |
Text
Last Measurement Q.A. Report 4/13/17 1:51:33 PM Page 1
- G E N I E Q U A L I T Y A S S U R A N C E *****
Last Results Report 4/13/17 1:51:33 PM QA File: C:\\GENIE2K\\CAMFILES\\UNC 2017 856 Sample ID: UNC Daily QC 041 Sample Quantity: 1.0000E+000 Sample Date: 6/1/11 12:00:00 AM Measurement Date: 4/13/17 1:44:42 PM Elapsed Live Time: 300.0 seconds Elapsed Real Time: 352.2 seconds Parameter Description Value Deviation/Flags
[Mean +/- Std. Dev.] < LU : SD : UD : BS >
Peak FWHM (121.8 keV) 9.6798E-001 5.7191E-001
[SD: 9.6050E-001+/- 0.013] < : : : >
Peak FWHM (1407.92 keV) 2.4716E+000 9.3223E-001
[SD: 2.3585E+000+/- 0.121] < : : : >
Peak FWHM (964.13 keV) 1.9986E+000 1.1468E+000
[SD: 1.9105E+000+/- 0.077] < : : : >
Peak energy (964.13 keV) 9.6410E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (121.8 keV) 1.2194E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (1407.92 keV 1.4084E+003 0.00
[0.00+/-0.00] < : : : >
Corrected activity (121. 5.4531E-001 -7.2583E-001
[SD: 5.5028E-001+/- 0.007] < : : : >
Corrected activity (964. 4.8466E-001 3.6183E-002
[SD: 4.8436E-001+/- 0.008] < : : : >
Corrected activity (1407 4.8999E-001 6.0889E-001
[SD: 4.8517E-001+/- 0.008] < : : : >
Flags Key: LU = Lower/Upper Bounds Test (Ab = Above, Be = Below)
SD = Sample Driven N-Sigma Test (In = Investigate, Ac = Action)
UD = User Driven N-Sigma Test (In = Investigate, Ac = Action)
BS = Measurement Bias Test (In = Investigate, Ac = Action)