Last Measurement Q.A. Report 5/1/17 7:59:53 AM Page 1
- G E N I E Q U A L I T Y A S S U R A N C E *****
Last Results Report 5/1/17 7:59:53 AM QA File: C:\\GENIE2K\\CAMFILES\\UNC 2017 856 Sample ID: Daily QC 0501201 Sample Quantity: 1.0000E+000 Sample Date: 6/1/11 12:00:00 AM Measurement Date: 5/1/17 7:49:51 AM Elapsed Live Time: 300.0 seconds Elapsed Real Time: 350.9 seconds Parameter Description Value Deviation/Flags
[Mean +/- Std. Dev.] < LU : SD : UD : BS >
Peak FWHM (121.8 keV) 9.5898E-001 -2.3769E-001
[SD: 9.6195E-001+/- 0.013] < : : : >
Peak FWHM (1407.92 keV) 2.2657E+000 -8.5375E-001
[SD: 2.3787E+000+/- 0.132] < : : : >
Peak FWHM (964.13 keV) 1.8578E+000 -6.8860E-001
[SD: 1.9126E+000+/- 0.080] < : : : >
Peak energy (964.13 keV) 9.6435E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (121.8 keV) 1.2199E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (1407.92 keV 1.4088E+003 0.00
[0.00+/-0.00] < : : : >
Corrected activity (121. 5.4671E-001 -4.4140E-001
[SD: 5.4950E-001+/- 0.006] < : : : >
Corrected activity (964. 4.8355E-001 -1.5564E-001
[SD: 4.8470E-001+/- 0.007] < : : : >
Corrected activity (1407 4.8530E-001 3.5107E-002
[SD: 4.8505E-001+/- 0.007] < : : : >
Flags Key: LU = Lower/Upper Bounds Test (Ab = Above, Be = Below)
SD = Sample Driven N-Sigma Test (In = Investigate, Ac = Action)
UD = User Driven N-Sigma Test (In = Investigate, Ac = Action)
BS = Measurement Bias Test (In = Investigate, Ac = Action)