ML19099A077
| ML19099A077 | |
| Person / Time | |
|---|---|
| Site: | 07000371 |
| Issue date: | 03/01/2018 |
| From: | Cabrera Services |
| To: | NRC Region 1 |
| Shared Package | |
| ml051740240 | List:
|
| References | |
| Download: ML19099A077 (2) | |
Text
Last Measurement Q.A. Report 6/15/17 8:20:13 AM Page 1
- G E N I E Q U A L I T Y A S S U R A N C E *****
Last Results Report 6/15/17 8:20:13 AM QA File: C:\\GENIE2K\\CAMFILES\\UNC 2017 856 Sample ID: Daily QC 0615201 Sample Quantity: 1.0000E+000 Sample Date: 6/1/11 2:00:00 PM Measurement Date: 6/15/17 8:00:15 AM Elapsed Live Time: 300.0 seconds Elapsed Real Time: 351.2 seconds Parameter Description Value Deviation/Flags
[Mean +/- Std. Dev.] < LU : SD : UD : BS >
Peak FWHM (121.8 keV) 9.7837E-001 1.3774E+000
[SD: 9.6266E-001+/- 0.011] < : : : >
Peak FWHM (1407.92 keV) 2.2538E+000 -9.5150E-001
[SD: 2.3911E+000+/- 0.144] < : : : >
Peak FWHM (964.13 keV) 1.8544E+000 -7.5240E-001
[SD: 1.9196E+000+/- 0.087] < : : : >
Peak energy (964.13 keV) 9.6419E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (121.8 keV) 1.2196E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (1407.92 keV 1.4085E+003 0.00
[0.00+/-0.00] < : : : >
Corrected activity (121. 5.4358E-001 -2.8327E-001
[SD: 5.4682E-001+/- 0.011] < : : : >
Corrected activity (964. 4.7638E-001 -1.1108E+000
[SD: 4.8384E-001+/- 0.007] < : : : >
Corrected activity (1407 4.8497E-001 -3.2640E-002
[SD: 4.8519E-001+/- 0.007] < : : : >
Flags Key: LU = Lower/Upper Bounds Test (Ab = Above, Be = Below)
SD = Sample Driven N-Sigma Test (In = Investigate, Ac = Action)
UD = User Driven N-Sigma Test (In = Investigate, Ac = Action)
BS = Measurement Bias Test (In = Investigate, Ac = Action)