Last Measurement Q.A. Report 6/8/17 9:32:58 AM Page 1
- G E N I E Q U A L I T Y A S S U R A N C E *****
Last Results Report 6/8/17 9:32:58 AM QA File: C:\\GENIE2K\\CAMFILES\\UNC 2017 856 Sample ID: Daily QC 0608201 Sample Quantity: 1.0000E+000 Sample Date: 6/1/11 2:00:00 PM Measurement Date: 6/8/17 8:21:50 AM Elapsed Live Time: 300.0 seconds Elapsed Real Time: 351.5 seconds Parameter Description Value Deviation/Flags
[Mean +/- Std. Dev.] < LU : SD : UD : BS >
Peak FWHM (121.8 keV) 9.7782E-001 1.3613E+000
[SD: 9.6240E-001+/- 0.011] < : : : >
Peak FWHM (1407.92 keV) 2.4685E+000 5.4256E-001
[SD: 2.3898E+000+/- 0.145] < : : : >
Peak FWHM (964.13 keV) 1.9670E+000 5.5180E-001
[SD: 1.9188E+000+/- 0.087] < : : : >
Peak energy (964.13 keV) 9.6404E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (121.8 keV) 1.2193E+002 0.00
[0.00+/-0.00] < : : : >
Peak energy (1407.92 keV 1.4083E+003 0.00
[0.00+/-0.00] < : : : >
Corrected activity (121. 5.4568E-001 -1.0114E-001
[SD: 5.4684E-001+/- 0.012] < : : : >
Corrected activity (964. 4.8403E-001 2.8111E-002
[SD: 4.8384E-001+/- 0.007] < : : : >
Corrected activity (1407 4.8013E-001 -7.6112E-001
[SD: 4.8528E-001+/- 0.007] < : : : >
Flags Key: LU = Lower/Upper Bounds Test (Ab = Above, Be = Below)
SD = Sample Driven N-Sigma Test (In = Investigate, Ac = Action)
UD = User Driven N-Sigma Test (In = Investigate, Ac = Action)