Last Measurement Q.A. Report 3/28/17 8:00:01 AM Page 1

          • G E N I E Q U A L I T Y A S S U R A N C E *****

Last Results Report 3/28/17 8:00:01 AM QA File: C:\\GENIE2K\\CAMFILES\\UNC 2017 856 Sample ID: Daily QC 0328201 Sample Quantity: 1.0000E+000 Sample Date: 6/1/11 12:00:00 AM Measurement Date: 3/28/17 7:50:28 AM Elapsed Live Time: 300.0 seconds Elapsed Real Time: 352.3 seconds Parameter Description Value Deviation/Flags

[Mean +/- Std. Dev.] < LU : SD : UD : BS >

Peak FWHM (121.8 keV) 9.5189E-001 -1.8766E-001

[SD: 9.5382E-001+/- 0.010] < : : : >

Peak FWHM (1407.92 keV) 2.2434E+000 -7.4775E-001

[SD: 2.3168E+000+/- 0.098] < : : : >

Peak FWHM (964.13 keV) 1.8600E+000 -4.4035E-001

[SD: 1.8872E+000+/- 0.062] < : : : >

Peak energy (964.13 keV) 9.6387E+002 0.00

[0.00+/-0.00] < : : : >

Peak energy (121.8 keV) 1.2197E+002 0.00

[0.00+/-0.00] < : : : >

Peak energy (1407.92 keV 1.4080E+003 0.00

[0.00+/-0.00] < : : : >

Corrected activity (121. 5.5326E-001 6.6753E-001

[SD: 5.4910E-001+/- 0.006] < : : : >

Corrected activity (964. 4.8543E-001 3.5327E-001

[SD: 4.8228E-001+/- 0.009] < : : : >

Corrected activity (1407 4.8529E-001 3.6226E-001

[SD: 4.8229E-001+/- 0.008] < : : : >

Flags Key: LU = Lower/Upper Bounds Test (Ab = Above, Be = Below)

SD = Sample Driven N-Sigma Test (In = Investigate, Ac = Action)

UD = User Driven N-Sigma Test (In = Investigate, Ac = Action)

BS = Measurement Bias Test (In = Investigate, Ac = Action)