ML19098A799
Text
Revision 2 Radiological Surveys Location:
RWP#
Survey Type:
pg. 1 of 2 No.
D E
No.
D E
Dose Rate (urem/hr) 1 1
0 27 30 Petrie dish 1 exterior surfaces 2
2 0
36 20 Petrie dish 2 exterior surfaces 3
3 0
28 20 Petrie dish 3 exterior surfaces 4
4 0
38 20 Petrie dish 4 exterior surfaces 5
5 0
27 15 Petrie dish 5 exterior surfaces 6
6 1
34 20 Petrie dish 6 exterior surfaces 7
7 0
31 15 Jar 1 exterior surfaces 8
8 0
23 15 Jar 2 exterior surfaces 9
9 1
45 20 Jar 3 exterior surfaces 10 10 0
32 15 Jar 4 exterior surfaces 11 11 0
35 20 Jar 5 exterior surfaces 12 12 0
39 15 Jar 6 exterior surfaces 13 13 0
32 N/A Inside of packaging 14 14 0
29 10 Outside of packaging top 15 15 0
28 15 Outside of packaging bottom 16 16 0
27 15 Outside of packaging front 17 17 1
26 10 Outside of packaging back 18 18 0
33 15 Outside of packaging left side 19 19 0
23 10 Outside of packaging right side 20 20 21 21 22 22 23 23 24 24 25 25 Instrument Serial #
D Eff.
E Eff.
D Bkg.
E Bkg J Bkg Cal. Due 2929/
43-10-1 157320/
PR157821 0.35211 0.17966 0.2 29.2 N/A 16-May-17 1844 MicroRem N/A N/A N/A N/A 10 22-Dec-17 A/S Location Boundary Smear Dose Rate _______ /hr Direct Reading CPM/direct frisk Grab Sample Mike Winters Package contains six plastic jars each containing a petrie dish containing an item of interest.
New Haven, CT OP-001-02 Radiological Survey Sheet DOT Site: Former UNC Manufacturing Facility N/A Date:
Surveyed By:
Comments Key Reviewed By:
25-Jun-16 25-Jun-16 Nick Berliner Date:
25-Jun-16 Survey UNC-2016-011 - SNM DOT Direct Count (DPM/100 cm2)
Smear (DPM/100 cm2) circle one Back Side 10 urem/hr Front 15 urem/hr Bottom 15 urem/hr Right Side 10 urem/hr Top 10 urem/hr Left Side 15 urem/hr Max Max Max Max Max Max OP-001 CABRERA SERVICES, INC.
Page 15 of 15
CABRERA SMEAR COUNTING WORKSHEET (Rev 6) page of
Deff E eff Sample Count Time (min)
DFlag EFlag 0.3521 0.1797 1.0 5.0
0
,000 seq. #
Sample ID# and Description Date Tech.
Initial D
E D
E D
E D
E D
E dpm/100 cm2
> DD flag
> EEflag
- Morning Daily Count Sample (dpm/100 cm2)
Background Total Counts*
Sample Total Counts Background (cpm)
Sample Counts (cpm)
Daily Background Count Time (min) 69 Survey UNC-2016-011-01 6/25/2016 1
146 0
27 0.2 29.2 0.00 27
-0.6
-12 NMB 70 Survey UNC-2016-011-02 6/25/2016 1
146 0
36 0.2 29.2 0.00 36
-0.6 38 NMB 71 Survey UNC-2016-011-03 6/25/2016 1
146 0
28 0.2 29.2 0.00 28
-0.6
-7 NMB 72 Survey UNC-2016-011-04 6/25/2016 1
146 0
38 0.2 29.2 0.00 38
-0.6 49 NMB 73 Survey UNC-2016-011-05 6/25/2016 1
146 0
27 0.2 29.2 0.00 27
-0.6
-12 NMB 74 Survey UNC-2016-011-06 6/25/2016 1
146 1
34 0.2 29.2 1.00 34 2.3 27 NMB 75 Survey UNC-2016-011-07 6/25/2016 1
146 0
31 0.2 29.2 0.00 31
-0.6 10 NMB 76 Survey UNC-2016-011-08 6/25/2016 1
146 0
23 0.2 29.2 0.00 23
-0.6
-35 NMB 77 Survey UNC-2016-011-09 6/25/2016 1
146 1
45 0.2 29.2 1.00 45 2.3 88 NMB 78 Survey UNC-2016-011-10 6/25/2016 1
146 0
32 0.2 29.2 0.00 32
-0.6 16 NMB 79 Survey UNC-2016-011-11 6/25/2016 1
146 0
35 0.2 29.2 0.00 35
-0.6 32 NMB 80 Survey UNC-2016-011-12 6/25/2016 1
146 0
39 0.2 29.2 0.00 39
-0.6 55 NMB 81 Survey UNC-2016-011-13 6/25/2016 1
146 0
32 0.2 29.2 0.00 32
-0.6 16 NMB 82 Survey UNC-2016-011-14 6/25/2016 1
146 0
29 0.2 29.2 0.00 29
-0.6
-1 NMB 83 Survey UNC-2016-011-15 6/25/2016 1
146 0
28 0.2 29.2 0.00 28
-0.6
-7 NMB 84 Survey UNC-2016-011-16 6/25/2016 1
146 0
27 0.2 29.2 0.00 27
-0.6
-12 NMB 85 Survey UNC-2016-011-17 6/25/2016 1
146 1
26 0.2 29.2 1.00 26 2.3
-18 NMB 86 Survey UNC-2016-011-18 6/25/2016 1
146 0
33 0.2 29.2 0.00 33
-0.6 21 NMB 87 Survey UNC-2016-011-19 6/25/2016 1
146 0
23 0.2 29.2 0.00 23
-0.6
-35 NMB