ML19098A790
| ML19098A790 | |
| Person / Time | |
|---|---|
| Site: | 07000371 |
| Issue date: | 03/01/2018 |
| From: | Cabrera Services |
| To: | NRC Region 1 |
| Shared Package | |
| ml051740240 | List:
|
| References | |
| Download: ML19098A790 (3) | |
Text
Revision 2 Radiological Surveys Location:
RWP#
Survey Type:
pg. 1 of 3 No.
No.
1 20
-102 1
-1
-43 2
10
-34 2
-1
-55 3
10
-238 3
2 1
4 20
-255 4
7 12 5
0
-85 5
5
-4 6
-20
-238 6
-1
-21 7
-10
-102 7
2
-27 8
0
-119 8
-1 7
9
-10 17 9
-1
-49 10 10
-204 10
-1 46 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 Instrument Serial #
Eff.
Eff.
Bkg.
Bkg Bkg Cal. Due 2360/
43-93 184913/
PR199839 0.10133 0.05892 2.0 108 N/A 09-Jun-17 2929/
43-10-1 157320/
PR157821 0.35211 0.17966 0.4 29.8 N/A 16-May-17 A/S Location Boundary Smear Dose Rate _______ /hr Direct Reading CPM/direct frisk Grab Sample Nick Berliner Left front wheel Right front wheel Right rear wheel Left-hand railings circle one Left rear wheel Right-hand railings Smear (DPM/100 cm2)
Direct Count (DPM/100 cm2)
Control box Control box Front half of deck Rear half of deck Survey UNC-2016-003 - Scissorlift Outgoing Key Reviewed By:
17-Jun-16 17-Jun-16 Al Craig Date:
17-Jun-16 Conversion from counts to DPM/100 cm2 for direct counts and smears are provided on pages 2 and 3, respectively.
OP-001-02 Radiological Survey Sheet Outgoing Site: Former UNC Manufacturing Facility N/A Date:
Surveyed By:
Comments New Haven, CT OP-001 CABRERA SERVICES, INC.
Page 15 of 15
CABRERA STATIC COUNTING WORKSHEET (Rev 6) page 1 of 1 Detector Active Area (cm2) eff eff Static Count Time (min)
Flag Flag 100 0.1013 0.0589 1.0 1.0 5,000 5,000 Sample ID# and Description Date Tech.
Initial
dpm/100 cm2 Daily Background Count Time (min)
- Morning Daily Count Background Total Counts*
Sample Total Counts Background (cpm)
Sample Counts (cpm)
Sample (dpm/100 cm2)
> flag
> flag outgoing lift 1 6/17/2013 2
108 4
102 2.0 108.0 4.00 102 19.7
-102 AC outgoing lift 2 6/17/2013 2
108 3
106 2.0 108.0 3.00 106 9.9
-34 AC outgoing lift 3 6/17/2013 2
108 3
94 2.0 108.0 3.00 94 9.9
-238 AC outgoing lift 4 6/17/2013 2
108 4
93 2.0 108.0 4.00 93 19.7
-255 AC outgoing lift 5 6/17/2013 2
108 2
103 2.0 108.0 2.00 103 0.0
-85 AC outgoing lift 6 6/17/2013 2
108 0
94 2.0 108.0 0.00 94
-19.7
-238 AC outgoing lift 7 6/17/2013 2
108 1
102 2.0 108.0 1.00 102
-9.9
-102 AC outgoing lift 8 6/17/2013 2
108 2
101 2.0 108.0 2.00 101 0.0
-119 AC outgoing lift 9 6/17/2013 2
108 1
109 2.0 108.0 1.00 109
-9.9 17 AC outgoing lift 10 6/17/2013 2
108 3
96 2.0 108.0 3.00 96 9.9
-204 AC
CABRERA SMEAR COUNTING WORKSHEET (Rev 6) page 1 of 1 eff eff Sample Count Time (min)
Flag Flag 0.3521 0.1797 1.0 5.0 1,000 1,000 Sample ID# and Description Date Tech.
Initial
dpm/100 cm2
> flag
> flag
- Morning Daily Count Sample (dpm/100 cm2)
Background Total Counts*
Sample Total Counts Background (cpm)
Sample Counts (cpm)
Daily Background Count Time (min) outgoing lift 1 6/17/2013 2
149 0
22 0.4 29.8 0.00 22
-1.1
-43 AC outgoing lift 2 6/17/2013 2
149 0
20 0.4 29.8 0.00 20
-1.1
-55 AC outgoing lift 3 6/17/2013 2
149 1
30 0.4 29.8 1.00 30 1.7 1
AC outgoing lift 4 6/17/2013 2
149 3
32 0.4 29.8 3.00 32 7.4 12 AC outgoing lift 5 6/17/2013 2
149 2
29 0.4 29.8 2.00 29 4.5
-4 AC outgoing lift 6 6/17/2013 2
149 0
26 0.4 29.8 0.00 26
-1.1
-21 AC outgoing lift 7 6/17/2013 2
149 1
25 0.4 29.8 1.00 25 1.7
-27 AC outgoing lift 8 6/17/2013 2
149 0
31 0.4 29.8 0.00 31
-1.1 7
AC outgoing lift 9 6/17/2013 2
149 0
21 0.4 29.8 0.00 21
-1.1
-49 AC outgoing lift 10 6/17/2013 2
149 0
38 0.4 29.8 0.00 38
-1.1 46 AC