STDEDDtbl DPID RRunNum AnalRunID LabID QCTyp IndTestNamAnalMethodQCBatchIDColumnNum UR17090140 AS170921-1709014-1 SMP U-232 714R13 AS170921-1 UR17090140 AS170921-1709014-1 SMP U-234 714R13 AS170921-1 UR17090140 AS170921-1709014-1 SMP U-235 714R13 AS170921-1 UR17090140 AS170921-1709014-1 SMP U-238 714R13 AS170921-1 UR17090140 AS170921-1709014-2 SMP U-232 714R13 AS170921-1 UR17090140 AS170921-1709014-2 SMP U-234 714R13 AS170921-1 UR17090140 AS170921-1709014-2 SMP U-235 714R13 AS170921-1 UR17090140 AS170921-1709014-2 SMP U-238 714R13 AS170921-1 Page 1
STDEDDtbl Matrix OrderNum AnalDil LeachDate FileName ReportUnitsPrepBatchIPrepStartDPrepStartT SOIL 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOIL 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOIL 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOIL 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOLID 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOLID 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOLID 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM SOLID 1709014 Spectrum #pCi/g AS170921-9/22/2017 4:27:14 PM Page 2
STDEDDtbl ConcMethoExtractMeth%Moist FinalResultFlag EPAQual MDL IDL PRL 714R13 778R14 50.2 0.9 714R13 778R14 117000 M3 0
714R13 778R14 3960 M3 0
714R13 778R14 1680 M3 0
714R13 778R14 68 1
714R13 778R14 233 M3 1
714R13 778R14 11 M3 0.3 714R13 778R14 2.6 M3 0.6 Page 3
STDEDDtbl SpkAmt
%Rec RPD UpperLim LowerLim RPDLim TestType FieldID ClientName 89.03 56.3 110 30 TR UNC-6H-001 Cabrera_CT TA UNC-6H-001 Cabrera_CT TA UNC-6H-001 Cabrera_CT TA UNC-6H-001 Cabrera_CT 86.14 78.7 110 30 TR UNC-3H-002 Cabrera_CT TA UNC-3H-002 Cabrera_CT TA UNC-3H-002 Cabrera_CT TA UNC-3H-002 Cabrera_CT Page 4
STDEDDtbl DateCollec TimeCollecDateReceivClientProjIDClientProjNCOCNum RptBasis AnalItemTimAnalItemDa 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 8/30/2017 7:00:00 PM9/1/2017 10-1007.00UNC New Haven CT As Receive9:40:00 AM9/24/2017 Page 5
STDEDDtbl Suite TPU DER DERLIM MDC REQMDC TIC CASNO FRACTYP 8.5 0.9 FALSE 14158-29-3TO 20000 0
0.05 FALSE 13966-29-5TO 670 0
0.05 FALSE 15117-96-1TO 290 0
0.05 FALSE 7440-61-1 TO 11 1
FALSE 14158-29-3TO 39 1
0.05 FALSE 13966-29-5TO 2.8 0.3 0.05 FALSE 15117-96-1TO 1.1 0.6 0.05 FALSE 7440-61-1 TO Page 6
STDEDDtbl LabName ALSFC ALSFC ALSFC ALSFC ALSFC ALSFC ALSFC ALSFC Page 7