ML19095A661

From kanterella
Jump to navigation Jump to search
Appendix E - IMC Weights and U Manifest Info
ML19095A661
Person / Time
Site: 07000371
(SNM-0368)
Issue date: 03/01/2018
From:
Cabrera Services
To:
NRC Region 1
Shared Package
ml051740240 List: ... further results
References
Download: ML19095A661 (5)


Text

Truck/IMC Tare weights GFLU-2079 4640 8440 4900 10380 7500 10760 4880 9200 4720 10380 7740 10700 34380 Total Net Weight (lbs.)

25480 Cubic Yards 12.74 15620 U-234 (pCi/g) 2.46094977 Total activity U-234 (pCi) 28442509.63 U-235 (pCi/g) 0.091146288 Total activity U-235 (pCi) 1053426.283 U-238 (pCi/g) 0.240452577 Total activity U-238 (pCi) 2779038.733 U-234 (g) 0.004575082 U-235 (g) 0.487450092 U-238 (g) 8.268024372 Total U Mass (g) 8.760049546 U Enrichment (Wt U-235 %)

5.56%

GFLU-1451 BFLU-0011 GFLU-2120 GFLU-2008 EERU-0226 BFLU-0074 7500 10240 8540 8740 8200 8760 9170 9410 9520 9900 7840 8680 9830 8980 10380 10340 7680 8620 8570 10240 9040 9160 8840 8720 9630 10410 10980 10180 8200 7600 9780 9800 10720 10240 8300 7620 20100 24700 24800 24180 14680 15620 10.05 12.35 12.4 12.09 7.34 7.81 1.087891454 2.14 44.91 52.17 6.29421989 4.882858595 9918531.186 23975985.49 505196667 572193439.1 41911548.52 34595604.02 0.040292276 0.0795 0.339 0.376 0.233119255 0.180846615 367353.0069 890696.6574 3813441.77 4123916.678 1552279.575 1281318.668 0.872 0.7687 1.57409405 1.259598051 1.653649871 1.593809921 7950204.187 8612308.434 17707126.8 13815099.5 11011217.91 11292323.11 0.001595432 0.003856625 0.08126274 0.092039418 0.006741627 0.00556483 0.169984611 0.412150499 1.76458721 1.908252715 0.718283599 0.592902335 23.6529564 25.62280806 52.68115 41.10183064 32.75989535 33.59622216 23.82453644 26.03881518 54.5269999 43.10212278 33.48492058 34.19468932 0.71%

1.58%

3.24%

4.43%

2.15%

1.73%

GFLU-2198 GFLU-1483 ERRU-000312 MHFU-002362 GFLU-2002 GFLU-002165 8800 9500 8820 8760 8900 8640 8160 10220 10620 9600 9200 8820 8220 10160 10120 9820 10320 10200 8660 9900 9880 9680 10260 10420 7960 10040 9640 9460 9420 9940 8240 10420 9980 9820 9580 9920 15660 25860 24680 22760 23300 23560 7.83 12.93 12.34 11.38 11.65 11.78 84.05508163 65.94486516 121.128058 43.65798522 60.85216977 78.01382106 597064806.1 773526587.3 1355987389 450714663.7 643128461.8 833705327.2 3.113151171 2.442402413 2.771766377 1.068229996 2.253784066 2.063573439 22113511.34 28649132.86 31028981.33 11028152.61 23819572.66 22052658.69 2.18433238 2.053802552 1.690738935 1.626736289 1.971648164 1.749463644 15515873.21 24090895.86 18927247.01 16794038.84 20837762.33 18695881.58 0.096040069 0.124424595 0.218115556 0.07249911 0.103449577 0.134104566 10.23254623 13.25676289 14.35798599 5.103037671 11.02198898 10.20438799 46.16186753 71.67374523 56.31117613 49.96458697 61.99522331 55.62283199 56.49045382 85.05493272 70.88727767 55.14012375 73.12066187 65.96132454 18.11%

15.59%

20.25%

9.25%

15.07%

15.47%

GFLU-001032 EERU-000310 GFLU-001742 GFLU-002132 UNC-6H-001 UNC-3H-002 8760 8760 8760 8760 9460 8860 8740 9460 9820 10560 9480 9540 9680 10480 9460 9560 9480 10000 9080 9460 9700 9900 8460 9460 22520 24180 19600 21860 1

1 11.26 12.09 9.8 10.93 30.63775288 16.19884556 0.479446792 21.08120464 117000 233 312961587.2 177666727 4262478.775 209031300.4 117000 233 1.134731588 0.525763672 0.017757289 0.585041574 3960 11 11591169.9 5766504.192 157869.5842 5800996.816 3960 11 1.432047554 1.383843791 1.438171213 1.272046184 1680 2.6 14628222.8 15177809.82 12785932.38 12613011.1 1680 2.6 0.050341022 0.028578346 0.000685635 0.033623453 0.008537 1.7E-05 5.36356167 2.668324348 0.073050715 2.684285059 0.831164 0.002309 43.52098487 45.1560822 38.03991622 37.52545148 2.26716 0.003509 48.93488756 47.8529849 38.11365257 40.24335999 3.106861 0.005834 10.96%

5.58%

0.19%

6.67%

26.75%

39.57%

IMC Status Gross Weight (lbs)

Net Weight (lbs)

Contents enriched in U-235 total grams U-235 pCi Ci pCi/g pCi Ci pCi/g pCi Ci pCi/g GFLU-2079 Shipped 32880 25480 asbestos debris in bag 5.56%

0.49 1.05E+06 1.05E-06 0.091 2.78E+06 2.78E-06 0.240 2.84E+07 2.84E-05 2.461 GFLU-1451 Shipped 27500 20100 asbestos debris in bag 0.71%

0.17 3.67E+05 3.67E-07 0.040 7.95E+06 7.95E-06 0.872 9.92E+06 9.92E-06 1.088 BFLU-0011 Shipped 32100 24700 asbestos debris in bag 1.58%

0.41 8.91E+05 8.91E-07 0.079 8.61E+06 8.61E-06 0.769 2.40E+07 2.40E-05 2.140 GFLU-2120 Shipped 32200 24800 asbestos debris in bag 3.24%

1.76 3.81E+06 3.81E-06 0.339 1.77E+07 1.77E-05 1.574 5.05E+08 5.05E-04 44.910 GFLU-2008 Shipped 31580 24180 asbestos debris in bag 4.43%

1.91 4.12E+06 4.12E-06 0.376 1.38E+07 1.38E-05 1.260 5.72E+08 5.72E-04 52.170 EERU-0226 Shipped 22080 14680 asbestos debris in bag 2.15%

0.72 1.55E+06 1.55E-06 0.233 1.10E+07 1.10E-05 1.654 4.19E+07 4.19E-05 6.294 BFLU-0074 Shipped 23020 15620 asbestos debris in bag 1.73%

0.59 1.28E+06 1.28E-06 0.181 1.13E+07 1.13E-05 1.594 3.46E+07 3.46E-05 4.883 GFLU-2198 Shipped 23060 15660 asbestos debris in bag 18.11%

10.23 2.21E+07 2.21E-05 3.113 1.55E+07 1.55E-05 2.184 5.97E+08 5.97E-04 84.055 GFLU-1483 Shipped 33260 25860 asbestos debris in bag 15.59%

13.26 2.86E+07 2.86E-05 2.442 2.41E+07 2.41E-05 2.054 7.74E+08 7.74E-04 65.945 ERRU-000312 Shipped 32080 24680 asbestos debris in bag 20.25%

14.36 3.10E+07 3.10E-05 2.772 1.89E+07 1.89E-05 1.691 1.36E+09 1.36E-03 121.128 MHFU-002362 Shipped 30160 22760 asbestos debris in bag 9.25%

5.10 1.10E+07 1.10E-05 1.068 1.68E+07 1.68E-05 1.627 4.51E+08 4.51E-04 43.658 GFLU-2002 Shipped 30700 23300 asbestos debris in bag 15.07%

11.02 2.38E+07 2.38E-05 2.254 2.08E+07 2.08E-05 1.972 6.43E+08 6.43E-04 60.852 GFLU-002165 Shipped 30960 23560 asbestos debris in bag 15.47%

10.20 2.21E+07 2.21E-05 2.064 1.87E+07 1.87E-05 1.749 8.34E+08 8.34E-04 78.014 GFLU-001032 Shipped 29920 22520 asbestos debris in bag 10.96%

5.36 1.16E+07 1.16E-05 1.135 1.46E+07 1.46E-05 1.432 3.13E+08 3.13E-04 30.638 EERU-000310 Shipped 31580 24180 asbestos debris in bag 5.58%

2.67 5.77E+06 5.77E-06 0.526 1.52E+07 1.52E-05 1.384 1.78E+08 1.78E-04 16.199 GFLU-001742 Shipped 27000 19600 asbestos debris in bag 0.19%

0.07 1.58E+05 1.58E-07 0.018 1.28E+07 1.28E-05 1.438 4.26E+06 4.26E-06 0.479 GFLU-002132 Shipped 29260 21860 asbestos debris in bag 6.67%

2.68 5.80E+06 5.80E-06 0.585 1.26E+07 1.26E-05 1.272 2.09E+08 2.09E-04 21.081 Uranium Activity Calculations for 741 Forms and Waste Manifests Total U-235 Total U-238 Total U-234