Category:Letter type:PNP
MONTHYEARPNP 2024-030, Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 02024-08-0202 August 2024 Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 0 PNP 2024-019, Updated Final Hazards Summary Report, Revision 192024-06-0404 June 2024 Updated Final Hazards Summary Report, Revision 19 PNP 2023-015, License Termination Plan, Revision 42023-05-16016 May 2023 License Termination Plan, Revision 4 PNP 2023-007, and Big Rock Point, 2022 Annual Radioactive Effluent Release and Waste Disposal Reports2023-04-19019 April 2023 and Big Rock Point, 2022 Annual Radioactive Effluent Release and Waste Disposal Reports PNP 2023-013, 2022 Radiological Environmental Operating Report2023-04-12012 April 2023 2022 Radiological Environmental Operating Report PNP 2023-009, Report of Changes, Tests and Experiments and Summary of Commitment Changes2023-03-28028 March 2023 Report of Changes, Tests and Experiments and Summary of Commitment Changes PNP 2023-003, Independent Spent Fuel Storage Installation Radioactive Effluent Release Report2023-02-15015 February 2023 Independent Spent Fuel Storage Installation Radioactive Effluent Release Report PNP 2022-019, & Big Rock Point - Notification of Expected Date of Transfer of Ownership of Nuclear Plants to Holtec Palisades, LLC; and Notification of Receipt of All Required Regulatory Approvals2022-06-24024 June 2022 & Big Rock Point - Notification of Expected Date of Transfer of Ownership of Nuclear Plants to Holtec Palisades, LLC; and Notification of Receipt of All Required Regulatory Approvals PNP 2022-003, and Big Pock Point Plant - 2021 Annual Radioactive Effluent Release and Waste Disposal Report2022-04-25025 April 2022 and Big Pock Point Plant - 2021 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2022-001, 2021 ISFSI Annual Radioactive Effluent Release Report2022-02-24024 February 2022 2021 ISFSI Annual Radioactive Effluent Release Report PNP 2021-023, Biennial Update License Termination Plan2021-05-19019 May 2021 Biennial Update License Termination Plan PNP 2021-015, and Big Rock Point, Submittal of 2020 Annual Radioactive Effluent Release and Waste Disposal Report2021-04-21021 April 2021 and Big Rock Point, Submittal of 2020 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2021-009, 2020 ISFSI Annual Radioactive Effluent Release Report2021-02-25025 February 2021 2020 ISFSI Annual Radioactive Effluent Release Report PNP 2020-042, and Big Rock Point Application for Order Consenting to Transfers of Control of Licenses and Approving Conforming License Amendments2020-12-23023 December 2020 and Big Rock Point Application for Order Consenting to Transfers of Control of Licenses and Approving Conforming License Amendments PNP 2020-041, Independent Spent Fuel Storage Installation Radioactive Effluent Release Report2020-12-0909 December 2020 Independent Spent Fuel Storage Installation Radioactive Effluent Release Report PNP 2019-024, Biennial Update - Big Rock Point License Termination Plan2019-05-21021 May 2019 Biennial Update - Big Rock Point License Termination Plan PNP 2019-016, & Big Rock Point - 2018 Annual Radioactive Effluent Release and Waste Disposal Report2019-04-24024 April 2019 & Big Rock Point - 2018 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2019-008, Report of Changes, Tests and Experiments and Summary of Commitment Changes2019-04-0808 April 2019 Report of Changes, Tests and Experiments and Summary of Commitment Changes PNP 2019-013, Submittal of 2018 Personnel Exposure and Monitoring Report2019-03-26026 March 2019 Submittal of 2018 Personnel Exposure and Monitoring Report PNP 2019-014, 2018 Radiological Environmental Operating Report2019-03-0707 March 2019 2018 Radiological Environmental Operating Report PNP 2019-006, 2018 ISFSI Annual Radioactive Effluent Release Report2019-02-27027 February 2019 2018 ISFSI Annual Radioactive Effluent Release Report PNP 2018-037, Request for Exemption from 10 CFR 50.54(w)(1) - Big Rock Point Independent Spent Fuel Storage Installation2018-08-10010 August 2018 Request for Exemption from 10 CFR 50.54(w)(1) - Big Rock Point Independent Spent Fuel Storage Installation PNP 2018-019, 2017 Radiological Environmental Operating Report2018-04-20020 April 2018 2017 Radiological Environmental Operating Report PNP 2018-016, Submittal of 2017 Personnel Exposure and Monitoring Report2018-04-0202 April 2018 Submittal of 2017 Personnel Exposure and Monitoring Report PNP 2017-041, Biennial Update - Big Rock Point License Termination Plan2017-06-20020 June 2017 Biennial Update - Big Rock Point License Termination Plan PNP 2017-009, Transmittal of 2016 Annual Radioactive Effluent Release and Waste Disposal Report2017-04-28028 April 2017 Transmittal of 2016 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2017-013, 2016 Radiological Environmental Operating Report2017-04-0707 April 2017 2016 Radiological Environmental Operating Report PNP 2017-022, Report of Changes, Tests and Experiments and Summary of Commitment Changes2017-04-0101 April 2017 Report of Changes, Tests and Experiments and Summary of Commitment Changes PNP 2017-008, Submittal of 2016 ISFSI Annual Radioactive Effluent Release Report2017-02-0101 February 2017 Submittal of 2016 ISFSI Annual Radioactive Effluent Release Report PNP 2017-006, Letter Regarding Electronic Submission of 2016 Personnel Exposure and Monitoring Data2017-01-24024 January 2017 Letter Regarding Electronic Submission of 2016 Personnel Exposure and Monitoring Data PNP 2016-035, Revision to Big Rock Point Emergency Plan Implementing Procedure2016-05-0404 May 2016 Revision to Big Rock Point Emergency Plan Implementing Procedure PNP 2016-029, ISFSI - Transmittal of 2015 Radiological Environmental Operating Report2016-04-25025 April 2016 ISFSI - Transmittal of 2015 Radiological Environmental Operating Report PNP 2016-024, Transmittal of 2015 Annual Radioactive Effluent Release and Waste Disposal Report2016-04-25025 April 2016 Transmittal of 2015 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2016-010, Transmittal of 2015 ISFSI Annual Radioactive Effluent Release Report2016-02-17017 February 2016 Transmittal of 2015 ISFSI Annual Radioactive Effluent Release Report PNP 2016-011, Submittal of 2015 Personnel Exposure and Monitoring Report2016-02-16016 February 2016 Submittal of 2015 Personnel Exposure and Monitoring Report PNP 2015-046, Biennial Update - Big Rock Point License Termination Plan2015-07-15015 July 2015 Biennial Update - Big Rock Point License Termination Plan PNP 2015-029, Annual Radioactive Effluent Release and Waste Disposal Report2015-04-27027 April 2015 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2015-031, Independent Spent Fuel Storage Installation (ISFSI) Submits 2014 Radiological Environmental Operating Report2015-04-15015 April 2015 Independent Spent Fuel Storage Installation (ISFSI) Submits 2014 Radiological Environmental Operating Report PNP 2015-021, Submits Report of Changes, Tests and Experiments and Summary of Commitment Changes for the Period of April 1, 2013 Through March 31,20152015-04-0101 April 2015 Submits Report of Changes, Tests and Experiments and Summary of Commitment Changes for the Period of April 1, 2013 Through March 31,2015 PNP 2015-012, 2014 Personnel Exposure and Monitoring Report2015-02-23023 February 2015 2014 Personnel Exposure and Monitoring Report PNP 2015-011, ISFSI Annual Radioactive Effluent Release Report2015-02-0404 February 2015 ISFSI Annual Radioactive Effluent Release Report PNP 2014-044, & Big Rock Point - 2013 Annual Radioactive Effluent Release and Waste Disposal Report2014-04-30030 April 2014 & Big Rock Point - 2013 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2014-041, 2013 Radiological Environmental Operating Report2014-04-17017 April 2014 2013 Radiological Environmental Operating Report PNP 2014-018, 2013 Personnel Exposure and Monitoring Report2014-02-20020 February 2014 2013 Personnel Exposure and Monitoring Report PNP 2014-014, 2013 ISFSI Annual Radioactive Effluent Release Report2014-02-20020 February 2014 2013 ISFSI Annual Radioactive Effluent Release Report PNP 2013-030, License Termination Plan, Revision 32013-07-17017 July 2013 License Termination Plan, Revision 3 PNP 2013-038, 2012 Annual Radioactive Effluent Release and Waste Disposal Report2013-04-23023 April 2013 2012 Annual Radioactive Effluent Release and Waste Disposal Report PNP 2013-037, 2012 Radiological Environmental Operating Report2013-04-17017 April 2013 2012 Radiological Environmental Operating Report PNP 2013-016, 2012 ISFSI Annual Radioactive Effluent Release Report2013-02-26026 February 2013 2012 ISFSI Annual Radioactive Effluent Release Report PNP 2012-055, Request for Exemption from Emergency Planning and Preparedness Requirements2012-06-20020 June 2012 Request for Exemption from Emergency Planning and Preparedness Requirements 2024-08-02
[Table view] |
Text
- ~* Entergy Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Tel 269 764 2000 Jeffery A. Hardy Regulatory Assurance Manager PNP 2019-006 10 CFR 72.44 February 27,2019 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
2018 ISFSI Annual Radioactive Effluent Release Report Big Rock Point Dockets 50-155 and 72-043 License No. DPR-6
Dear Sir or Madam:
In accordance with 10 CFR 72.44(d)(3), Entergy Nuclear Operations, Inc. is submitting the annual independent spent fuel storage installation (ISFSI) radioactive effluent release report for Big Rock Point for the period from January 2018 through December 2018.
This letter contains no new commitments and no revision to existing commitments.
Respectfu lIy, 94~;J.
JAH/bed
Attachment:
Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report CC Administrator, Region III, USNRC BRP Decommissioning Inspector, USNRC NMSS Project Manager, USNRC
ATTACHMENT INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BIG ROCK POINT January 2018 - December 2018 I. FACILITY DESCRIPTION The Independent Spent Fuel Storage Installation (ISFSI) is located within the owner-controlled area of the Sig Rock Point (SRP) site. The storage of spent fuel at SRP meets the requirements of 10 CFR 72, and the Certificate of Compliance No. 72-1026, issued by the Nuclear Regulatory Commission (NRC).
II. EFFLUENT LIMITS AND CONTROLS The ISFSI operates under effluent control limits as required by 10 CFR 72.104.
However, the design of the sealed storage canisters at the ISFSI precludes any gaseous or liquid effluent releases.
III. RADIOLOGICAL EFFLUENT RELEASES As noted in Section II, by design, there are no radioactive liquid or gaseous effluents originating from the ISFSI facility. The annual radiological surveillance performed during this reporting period did not indicate any release of radioactivity from the ISFSI.
IV.ISFSI ENVIRONMENTAL MONITORING PROGRAM The SRP Radiological Environmental Monitoring Program (REMP) is described in the Offsite Dose Calculation Manual (ODCM),Section I, Subsection 4.0. The ISFSI Environmental Monitoring Program, which is contained within the SRP REMP, consists of thermoluminescent dosimeters (TLDs) at four locations along the perimeter of the ISFSI site, and three control TLDs 10.5, 10.8, and 12.6 miles from the site. Quarterly TLDs are read quarterly, as reflected in Section VI.
Quarterly measurements are compared to control measurements to evaluate compliance with 10 CFR 72.104. The results for the ISFSI TLDs and the control TLDs measured in 2018 are summarized in Section VI.
V. SAMPLE ANOMALIES None.
Page 1 of 2
VI. ISFSI ENVIRONMENTAL MEASUREMENTS BRP ISFSI Environmental TLD Results (mR)
January 2018 - December 2018 TLD 1St Quarter 2na Quarter 3ra Quarter 4tn Quarter No.lLocation BRP-18 / 137 meters NW 18 14 22 18 of ISFSI BRP-19 / 137 meters SW 21 17 23 20 of ISFSI BRP-20 / 137 meters SE 22 19 25 21 of ISFSI BRP-21 / 137 meters NE 16 14 21 14 of ISFSI Control Location - Petoskey 21 15 22 18 BRP-05 Control Location - Boyne City 19 16 23 17 BRP-06 Control Location - Ironton 20 18 23 19 BRP-07 VII. CONCLUSIONS When compared to the control locations, it is evident that the dose from ISFSI operations during the reporting period does not exceed the limits as defined in 10 CFR 72.104.
Page 2 of 2