Category:Environmental Report
MONTHYEARML19030A9532019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 44-100 ML19030A9882019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.1 - Pages 20-34 ML19030A9862019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.1 - Pages 1-19 ML19030A9842019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix F.3 - Pages 1-7 ML19030A9832019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix F.2 - Pages 1-11 ML19030A9812019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix F.1 - Pages 1-145 ML19030A9782019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.4 - Pages 1-185 ML19030A9772019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 481-515 ML19030A9752019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 454-480 ML19030A9722019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 401-453 ML19030A9702019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 351-400 ML19030A9622019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 251-300 ML19030A9592019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 201-250 ML19030A9572019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 151-200 ML19030A9902019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.1 - Pages 35-45 ML19030A9502019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.3 - Pages 1-43 ML19030A9472019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.2 - Pages 70-104 ML19030A9452019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.2 - Pages 42-69 ML19030A9432019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.2 - Pages 1-41 ML19030A9412019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix E.1 - Pages 1-46 ML19030A9392019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix D.2 - Pages 31-38 ML19030A9352019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix D.2 - Pages 1-30 ML19030A9332019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix D.1 - Pages 17-32 ML19030A9312019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix D.1 - Pages 1-16 ML19030A9282019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1826-1849 ML19030A9242019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1801-1825 ML19030A9212019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1776-1800 ML19030A9172019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1751-1775 ML19030B0222019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.3 - Pages 21-30 ML19030A9122019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1726-1750 ML19030B0392019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix I.2 - Pages 1-9 ML19030B0372019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix I.1 - Pages 1-44 ML19030B0362019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix H.2 - Pages 91-111 ML19030B0352019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix H.2 - Pages 61-90 ML19030B0342019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix H.2 - Pages 31-60 ML19030B0332019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix H.2 - Pages 1-30 ML19030B0312019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix H.1 - Pages 1-18 ML19030B0292019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.6 - Pages 1-598 ML19030B0272019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.5 - Pages 1-13 ML19030B0252019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.4 - Pages 1-37 ML19030B0232019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.3 - Pages 31-47 ML19030A9092019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1701-1725 ML19030B0202019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.3 - Pages 1-20 ML19030B0172019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 88-91 ML19030B0142019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 80-87 ML19030B0122019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 70-79 ML19030B0082019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 60-69 ML19030B0062019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 50-59 ML19030B0042019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 40-49 ML19030B0012019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 30-39 2019-01-18
[Table view] Category:License-Application for Early Site Permit (ESP)
MONTHYEARML19030A5012019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 70-77 ML19030A4152019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 02 - Section 02.08 - Noise ML19030A4172019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 02 - Section 02.09 - Related Federal Project Activities ML19030A4202019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 03 - Plant Description ML19030A4222019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 04 - Environmental Impacts of Construction ML19030A4242019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.01 - Environmental Impacts of Station Operation ML19030A4262019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.02 - WATER-RELATED Impacts ML19030A4282019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.03 - Cooling System Impacts ML19030A4302019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.04 - Radiological Impacts of Normal Operation ML19030A4322019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.05 - Environmental Impacts of Waste ML19030A4342019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.06 - Transmission System Impacts ML19030A4362019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.07 - Uranium Fuel Cycle and Transportation Impacts ML19030A4392019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.08 - Socioeconomic Impacts ML19030A4412019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.09 - Decommissioning Impacts ML19030A4422019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.10 - Measures and Controls to Limit Adverse Impacts During Operation ML19030A4442019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 05 - Section 05.11 - Cumulative Impacts Related to Station Operation ML19030A4472019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 06 - Environmental Measurements and Monitoring Programs ML19030A4492019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 07 - Environmental Impacts of Postulated Accidents Involving Radioactive Materials ML19030A4502019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 08 - Need for Power ML19030A4532019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 09 - Alternatives ML19030A4552019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Chapter 10 - Environmental Consequences of the Proposed Action ML19030A4582019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages 0-A6 ML19030A4602019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A7-A11 ML19030A4632019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A12-A34 ML19030A4662019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A35-A46 ML19030A4692019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A47-A52 ML19030A4712019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A53-A54 ML19030A4742019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A55-A64 ML19030A4762019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix a - Consultation - Pages A65-A91 ML19030A4772019-01-18018 January 2019 Part 03 Environmental Report (Rev. 2) - Part 03 - Environmental Report - Appendix B - Environmental Protection Plan ML19030A4812019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Site Vicinity Geologic Map Plates - Plate 1 ML19030A4822019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Site Vicinity Geologic Map Plates - Plate 2A ML19030A4832019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Site Vicinity Geologic Map Plates - Plate 2B ML19030A4842019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Site Vicinity Geologic Map Plates - Plate 2C CNL-19-018, Resubmittal of Clinch River Nuclear Site Early Permit Application, Revision 22019-01-18018 January 2019 Resubmittal of Clinch River Nuclear Site Early Permit Application, Revision 2 ML19030A4862019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Site Vicinity Geologic Map Plates - Plate 2D ML19030A4872019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Index ML19030A4882019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - TVA Quality Assurance Program - Nuclear Quality Assurance Plan ML19030A4892019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Pages 1-46 ML19030A4902019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Pages 47-82 ML19030A4912019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix a - Pages 1-9 ML19030A4922019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix a - Pages 10-18 ML19030A4932019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 1-22 ML19030A4942019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 23-28 ML19030A4952019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 29-40 ML19030A4962019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 41-44 ML19030A4982019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 45-52 ML19030A4992019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 53-60 ML19030A5002019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 61-69 ML19030A5352019-01-18018 January 2019 Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix B.1 - Pages 353-361 2019-01-18
[Table view] |
Text
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Sample No.: L3-29 BH Project Number: 6468-13-1072 Boring No.: MP-118 Run. No.: N/A Tested By: Mike Hamilton b1H Sample Depth (ft): 97.6-99.0 Test Date: __:1.:.,:/2:..:6.:.,:/2:...:0....:.14-=------,--------L'phi/t lf Reviewed By: Allen Cottingham 1 f{\W..
Review Date: 1/30/2014 1..00-' 1~ Page 1 of 2 Rock Type (See boring log)
Moisture Condition Laboratory Air-Dry Specimen Diameter, (in) 2.39 Specimen Length, (in) 5.33 Length/Diameter Ratio 2.2 Specimen Conforms with Dimensional Requirements? Yes As-Tested Unit Weight, (pcf) '46&:t" I "~ H.> ~
Loading Rate {lb/sec) 160 v Test Duration to Failure, (min) 4.7 Uniaxial Compressive Strength, (psi) 4,870 Type of Break Shear Young's Modulus, (psi) 2,490,000 Poisson's Ratio 0.20 l
' I II
-4,500 I
I ~ I
\ I
-4,000 I I I \ I I
I
I
/
~ I \ I I
I I
/
~
I
/
/
-1,000 Average Adjusted Axial Strain (in/in)
I
- 500 - Average Adjusted r i Lateral Strain (infln) 0 0.0020 0.0010 0.0000 .().0010 .().0020 *0.0030 l ateril t Strain ( + ),(in/I n} Axial Strain I * ), (In/In)
Comments :
Young's Mod ulus and Poisson's Ratio determined using linear least-squares of stress-strai n data from 40% to 60%
of the uniaxial compressive strength (data points used are indica ted on the figure above).
Axial Strain is nega tive; Latera l Strain is positive. Load direction with respect to lithology: Vertical Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-20 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name : Clinch River SMR Sample No. : LJ-29 BH Project Number: 6468-13-1072 Boring No.: MP-11 B Run. No.: N/A Tested By: Mike Hamilton 1r1 Sample Depth (ft) : 97.6-99.0 Test Date: 1/26/2014 ~N Reviewed By: Allen Cottingham f'\~
Review Date: ...:1.:.:/3:..:0.:..:/2:.:0...:.1..:.4_ _ _ _ _ _ .)0-ll/ Page 2 of 2 1
Specimen Prior to Testing Specimen After Testing
("MP-118 LJ-29 BH before test.jpg"): ("MP-118 LJ-29 BH after test.jpg") :
Comments:
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-21 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012*10 Project Name: Clinch River SMR Sample No.: L3-31 BCH Project Number: 6468-13-1072 Boring No.: MP-122 Run. No.: N/A Tested By: Mike Hamilton ltlH Sample Depth (ft): 144.3-145.1 BI/ Jlf Test Date: ....:1:..::/2:..::6/c::2:..::01.:....4:..___ _ _....t,£f.-JI Reviewed By: Allen Cottingham l"\Pl.
Review Date : 1/30/2014 1-;H4 Page 1 of 2 Rock Type (See boring log)
Moisture Condition Laboratory Air-Dry Specimen Diameter, (in) 2.40 Specimen Length, (In) 5.10 Length/Diameter Ratio 2.1 Specimen Conforms with Dimensional Requirements? Nol1>
As-Tested Unit Weight, (pcf) 4%:6- I r,q f/et; Loading Rate (lb/sec) 160 v Test Duration to Failure, (min) 6 Uniaxial Compressive Strength, (psi) 12,430 Type of Break Columnar Young's Modulus, (psi) 5,550,000 Poisson's Ratio 0.22
-14,000
-8,000
.e.,;
(I)
~
-6,000
-4,000 -
- -Average Adjusted Axial Strain (in/in) l
- - Average Adjusted Lateral Strain (in/in) J 0
0.0020 0.0010 0.0000 .0.0010 *0.0020 *0.0030 Lateral Strain I * ], (In/In) Axial Strain ( *],(In/In)
Comments:
Young's Modulus and Poisson's Ralio determined using linear least-squares of slress-strain data from 40% to 60%
of the uniaxial compressive slrenglh (data points used are indicated on the figure above).
Axial Strain is negative; Lateral Strain is positive . Load direction with respect to lithology: Vertical (l ) Specimen did not meet End Flatness requirements of ASTM 04543-08. Authorization to proceed with test received from John Damm .
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-22 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Sample No. : L3-31 BCH Project Number: 6468-13-1072 Boring No.: MP-122 Run . No.: N/A Tested By: Mike Hamilton IJI H Sample Depth (ft): 144.3-145.1 Test Date : ...:1.:..:/2:..:.6:.::/2:..:.0-'-14'--_ __ _...~./+-'
/ ~t/N Reviewed By: Allen Cottingham r .>J~Fr{,
Review Date: 1/30/2014 1 -)o-t1 Page 2 of 2 Specimen Prior to Testing Specimen After Testing
("MP-122 L3-31 BCH before test.jpg") : ("MP-122 L3-31 BCH after test.jpg" ):
Comments:
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-23 of 91
Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 0 7012*1 0 Project Name: Clinch River SM R Sample No.: L2-13-BCH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No.: N/A Tested By: Mike Hamilton mrit Sample Depth (ft): 130.6'*131.8' Test Date: _1,;...,/7_;_/2-'0_1_4_ _ _ _ _ _ 1/t:z/*'-1 Reviewed By: Allen Cottingham f"(!rC Review Date: 1/21/2014 t
- 1't Page 1 of 2 Rock Type (See boring log)
Moisture Condition Laboratory Air-Dry Specimen Diameter, (in) 2.39 Specimen Length, (in) 5.67 Length/Diameter Ratio 2.4 Specimen Conforms with Dimensional Requirem ents? No 111 As-Tested Unit Weight, (pcf) ~ (G. f) l)eJ, f¥4t,(A-loading Rate (lb/sec) 130 ~
Test Duration to Failure, (min) 4 Uniaxial Compressive Strength, (psi) 5,000 Type of Break shear Young's Modulus, (psi) 11 ,080,000 Poi sson's Ratio 0.29
(
/
-4,000 -
I
-.; I
.; *3.000 --- - ----
t" f
-\1
~
- 2,000 ---- -;--- - -~--- -
-1.000 I - - Average Adjusted Axial ,__
I I i Strain (in/in)
- - Average Adjusted l ateral Strain (in/in) 0 0.0020 0 .0010 0.0000 -0.0010 -ll.0020 *0.0030 Lateral Strain I +], (In/in) Alllal Strain I * ), (In/In)
Comments :
Young's Modulus and Poisson's Ratio determined using linear least-squares of stress-strain data from 40% to 60%
of the uniaxial compressive strength (data points used are indicated on the figure above).
Axial Strain is negative; Lateral Strain is positive. Load direction with respect to lithology: Vertical (II Specimen did not meet end purpendicularity, end parrallelism and end flatness requirements of ASTM 04543-08. Authorization to proceed with test recei ved from John Damm.
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-24 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Sample No.: L2-13-BCH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No.: N/A Tested By: Mike Hamilton tntr'A Sample Depth (ft): 130.6'-131.8' Test Date: 1/7/2014
~~~-----------
1/1.-'t /N Reviewed By: Allen Cottingham .~
Review Date: 1/21/2014 1, -z.,l
- t~ Page 2 of2 Specimen Prior to Testing Specimen After Testing
("MP-201 L2-13 BCH before test.jpg") ("MP-201 L2-13 BCH after test (2).jpg"):
Comments:
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-25 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compre ssion ASTM 07012-10 Project Name: Clinch River SMR Sample No. : L2-14-BCH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No.: NIA Tested By: Mike Hamilton ~~;4 Sample Depth (ft): 186.2'-186.6'
/7.;..:
Test Date: -'1-':-' 14
/2:;.;;0-,:...:......,_ _ _ _ _ t/t1/l ~
Reviewed By: Allen Cottingham lfi/'It.
Review Date: 1/21/2014 , .,, .t~ Page 1 of 2 Rock Type (See boring log)
Moisture Condition Laboratory Air-Dry Specimen Diameter, (in) 2.39 Specimen Length, (in) 4.93 Length/Diameter Ratio 2.1 Specimen Conforms with Dimensional Requirements ? No()
As-Tested Unit Weight, (pcf) ~t ~ ef!eCJ.
Loading Rate (lblsec) 130 v Test Duration to Failure, (min) 8 Uniaxial Compressive Strength, (psi) 9,900 Type of Break shear Young's Modulus, (psi) 3,700,000 Poi sson's Ratio 0.22
.a.ooo 1 ---~-
.e
.. -6,000
~
Cl)
~
-4,000
- - Average Adjusted Axial
- 2,000 - '-'-----~ Strain {in/in)
- - Average Adjusted Lateral Strain {in/in) 0 ~------------~-------'--
0.0010 0.0005 0.0000 .().0005 -------------------------
.().0010 .().0015 .Q.0020 .().0025 ---------------~
.().0030 .().0035 -0.0040 Lateral Stroln ( + ], (lnfln) Axial Strai n ( -], (In/in)
Comments:
Young's Modul us and Poisson's Ralio determined using linear least-squares of stress-strain data from 40% to 60%
of the uniaxial compressive strength {data points used are indicated on the figure above).
Ax*al Strain is negative; Lateral Strain is posi tive. Load direction with respect to lithology: Vertical 1' 1Specimen did not meet side straightness, end purpendicularity, end parrallelism, and end flatness requirements of ASTM 04543-08. Authorization to proceed with test received from John Damm.
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-26 of 91
Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Sample No.: L2*14-BCH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No.: N/A Tested By: Mike Hamilton /hli tJ Sample Depth (ft): 186.2'-186.6' Test Date: . .:;1n:.:. ./:.=2.: . .01:. .:4_ _ __ _ t/1'1/14 Reviewed By: Allen Cottingham rll4t:
Review Date: 1/21/2014 1- J,l-lq Page 2 of2 Specimen Prior to Testing Specimen After Testing
("MP-201 L2-14 BCH before test.jpg"): ("MP-201 L2-14 BCH after test (2).jpg"):
Comments:
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-27 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name : Clinch River SMR Sample No.: L2*16-BH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No. : N/A Tested By: Mike Hamilton M,;;J Sample Depth (ft): 338.3'-339.7' Test Date: _1'"'/7...:.;/2.;.;;0..;.14~----- 'ftt/lli Reviewed By: Allen Cottingham .M,f({.
Review Date : 1/21/2014 j-'2.1-\.Aj Page 1 of 2 Rock Type (See boring Jog)
Moisture Condition Laboratory Air-Dry Specimen Diameter, (in) 2.40 Specimen Length, (in) 5.24 Length/Diameter Ratio 2.2 Specimen Conforms with Dimensional Requirements? No 11 l As-Tested Unit Weight, (pcf) ~ t 1.> JtY.). ~/14 Loading Rate (lb/sec) 130 v Test Duration to Failure, (min) 13.7 Uniaxial Compressive Strength, (psi) 21 ,910 Type of Break Columnar Young's Modulus, (psi) 12,840,000 Poisson's Ratio 0.30
- 25.000 , . . - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
-20,000
.e R
"i'l *10,000
~
-5,000 - - Average Adjusted Axial Strain (in/in)
- - Average Adjusted Lateral Strain (in/in) oL-______________r~------------------~====~__J 0.0010 0.0005 0.0000 -0.0005 ~ .0010 -0.0015 ~.0020 Lateral Strain I+ 1. (In/in) Axial Strain I -1. (In/In)
Comments:
Young's Modulus and Poisson's Ratio determined using li near least-squares of stress-strain data from 40% to 60%
of the uniaxial compressive streng th (data points used are indicated on the figure above).
Axial Strain is negative; Lateral Strain is positive. Load direction with respect to lithology: Vertical
<*l Specimen did not meet end purpendicularily requirements of ASTM D4543-08.
Authorization to proceed with lest received from John Damm.
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-28 of 91
ame Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Sample No.: L2-16-BH Project Number: 6468-13-1072 Boring No.: MP-201 Run. No.: N/A Tested By: Mike Hamilton r19tt Sample Depth (ft): 338.3'-339.7' Test Date:_1.:../7"'"'/2_0_14
_ _ __ _ _ ",ltt(l'f Reviewed By: Allen Cottingham ",(\<.
Review Date: 1/21/2014 1-l.l - 1~ Page 2 of2 Specimen Prior to Testing Specimen After Testing
("MP-201 L2-16 BH before test.jpg"): ("MP-201 L2-16 BH after test (2).jpg"):
Comments:
Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-29 of 91