APPENDIX I -Groundwater Level Monitoring Through 2-18-2014-No Change for Rev. 4 1.1 - Manual Water Level Readings 1.2-Listing of Transducer Data Files Clinch River Data Report Rev. 4 CRP-1112.16 Page 11 of 1 a me
APPENDIX 1.1 -Manual Water Level Readings-No Change for Rev. 4 1.1.1 Long Term Observation Wells 1.1.2 Other Observation Wells Clinch River Data Report Rev. 4 CRP-1112.16 Page 1.1-1 of44 a me
APPENDIX 1.1 -Manual Water Level Readings-No Change for Rev. 4 1.1.1 Long Term Observation Wells Clinch River Data Report Rev. 4 CRP-1112.16 Page 1.1-2 of 44 a me
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-101U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 14:56 803.72 10/1/2013 11:40 803.72 10/9/2013 11:06 803.72 10/26/2013 13:59 803.72 11/5/2013 14:57 803.72 OW-101U 11/12/2013 11:35 803.72 11/23/2013 12:49 803.72 12/9/2013 9:09 803.72 12/20/2013 13:11 803.72 1/13/2014 8:45 803.72 1/16/2014 13:.55 803.72 2/18/2014 8:34 803.72 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatetiJiflc~IV\\t!P'b'ilt~~~E(M~lhP. 4 CRP-1112.16 Page 1.1-3 of 44 WATER LEVEL DEPTH (ft) 13.01 19.54 20.58 20.99 21.03 20.88 19.77 5.30 13.G7 7.98 8.34 11.86 WATER LEVEL ELEVATION (ft) 790.71 784.18 783.14 782.73 782.69 782.84 783.95 798.42 790.65 795.74 795.38 791.86 Prepared by/Date: ~
- 3 / 1 (I+--
Checked by/Date: fl~.4 :3/ ~ / 1 <(
NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-101L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 14:55 803.48 10/1/2013 11:45 803.48 10/9/2013 11:04 803.48 10/26/2013 13:56 803.48 11/5/2013 15:00 803.48 OW-101L 11/12/2013 11:36 803.48 11/23/2013 12:47 803.48 12/9/2013 8:50 803.48 12/20/2013 13:13 803.48 1/13/2014 8:47 803.48 1/16/2014 14:00 803.48 2/18/2014 8:42 803.48 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Water<Sn'ffl!Jif1Ril1\\l!tn~ii<fi~lf<Re\\Vl. 4 CRP-1112.16 Page 1.1-4 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 35.15 768.33 37.11 766.37 41.58 761.90 46.59 756.89 50.00 753.48 53.88 749.60 41.43 762.05 30.01 773.47 34.74 768.74 31.96 771.52 32.37 771.11 34.78 768.70 NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-1010 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 14:53 803.57 10/1/2013 11:50 803.57 10/9/2013 11:02 803.57 10/26/2013 13:54 803.57 11/5/2013 15:03 803.57 OW-1010 11/12/2013 11:37 803.57 11/23/2013 12:45 803.57 12/9/2013 8:58 803.57 12/20/2013 13:16 803.57 1/13/2014 8:50 803.57 1/16/2014 14:05 803.57 2/18/2014 8:48 803.57 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatetiJrt;~WR~il'IJm:iilftle~~~V! 4 CRP-1112.16 Page 1.1-5 of 44 WATER LEVEL WATER LEVEL DEPTH {ft)
ELEVATION (ft) 60.12 743.45 60.54 743.03 61.80 741.77 62.24 741.33 63.05 740.52 63.68 739.89 64.32 739.25 54.18 749.39 62.52 741.05 58.42 745.15 59.08 744.49 62.07 741.50 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-202U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 15:15 815.38 10/1/2013 8:17 815.38 10/9/2013 11:23 815.38 10/26/2013 14:15 815.38 11/5/2013 13:08 815.38 OW-202U 11/12/2013 12:04 815.38 11/23/2013 11:34 815.38 12/9/2013 15:08 815.38 12/20/2013 10:41 815.38 1/13/2014 9:26 815.38 1/16/2014 11:06 815.38 2/18/2014 11:32 815.38 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatedfiWc~P~,ftl~mJt~E!J.> 4 CRP-1112.16 Page 1.1-6 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 16.73 798.65 19.07 796.31 22.49 792.89 26.87 788.51 28.06 787.32 28.63 786.75 17.95 797.43 15.23 800.15 17.28 798.10 15.91 799.47 16.42 798.96 16.54 798.84
~
b)t;:IL Prepared by/Date: /Vi.
- I Checked by/Date: P64
'"S I "'I I r NOTES
OBSERVATION DATE WELL ID 9/24/2013 GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-202L CLINCH RIVER SMR PROJECT TIME 15:17 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 815.05 48.13 766.92 NOTES 10/2/2013.
7:55 815.05 48.88 766.17 Transducer in well. Rising head test still running on 10/1.
10/9/2013 11:21 815.05 10/26/2013 14:11 815.05 11/5/2013 13:06 815.05 OW-202L 11/12/2013 12:02 815.05 11/23/2013 11:32 815.05 12/9/2013 15:13 815.05 12/20/2013 10:38 815.05 1/13/2014 9:25 815.05 1/16/2014 11:00 815.05 2/18/2014 11:36 815.05 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watet'tfll'c~ipb~~ffi!&l>n11~1¥v?4 CRP-1112.16 Page 1.1-7 of 44 49.69 52.19 53.29 53.93 109.27 36.78 41.47 38.26 38.97 42.20 765.36 762.86 761.76 761.12 705.78 778.27 773.58 776.79 776.08 772.85 Prepared by/Date:
Checked by/Date:
Well still recovering after water quality sampling.
. t).J- ~*~ lj.t..
<GA-
'J 1'~/t'f
GROUNDWATER LEVEL
SUMMARY
- LONG* TERM OBSERVATION WELL OW*202D CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 15:19 815.00 10/1/2013 8:21 815.00 10/9/2013 11:18 815.00 10/26/2013 14:10 815.00 11/5/2013 13:05 815.00 OW-202D 11/12/2013 12:00 815.00 11/23/2013 11:30 815.00 12/9/2013 16:20 815.00 12/20/2013 10:34 815.00 1/13/2014 9:24 815.00 1/16/2014 10:52 815.00 2/18/2014 11:41 815.00 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatedJII'I'I:tfR~plf}MftlFffiljM\\~J.l 4 CRP-1112.16 Page 1.1-8 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 55.66 759.34 56.04 758.96 57.50 757.50 59.33 755.67 60.15 754.85 60.72 754.28 59.95 755.05 51.36 763.64 52.59 762.41 50.96 764.04 50.24 764.76 53.03 761.97 NOTES
OBSERVATION DATE WELLID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 11/5/2013 OW-409U 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1/13/2014 1/16/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW*409U CLINCH RIVER SMR PROJECT TIME 15:04 8:40 11:12 14:04 12:58 11:53 11:27 15:02 11:20 9:17 10:12 11:50 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 809.70 64.98 744.72 809.70 66.86 742.84 809.70 68.39 741.31 809.70 68.86 740.84 809.70 68.91 740.79 809.70 69.93 739.77 809.70 70.60 739.10 809.70 47.14 762.56 809.70 67.71 741.99 809.70 53.66 756.04 809.70 56.35 753.35 809.70 66.07 743.63
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88 NOTES
- 3. See Appendix E.1 for well construction details.
Prepared by/Date:
Checked by/Date:
/}t)J :?/ I til-
~
l/ ~/"1 WatetiJm~tl=Ri-Wiil'D~Uilflmjm¥t~ehP. 4 CRP-1112.16 Page 1.1-9 of 44
GROUNDWATER LEVEL
SUMMARY
- LONG* TERM OBSERVATION WELL OW-409L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 15:06 809.51 10/1/2013 8:43 809.51 10/9/2013 11:14 809.51 10/26/2013 14:05 809.51 11/5/2013 12:56 809.51 OW-409L 11/12/2013 11:56 809.51 11/23/2013 11:25 809.51 12/9/2013 14:56 809.51 12/20/2013 10:19 809.51 1/13/2014 9:18 809.51 1/16/2014 10:34 809.51 2/18/2014 11:55 809.51 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatedJm~~~~ilUM!flNI!~FRf!ll) 4 CRP-1112.16 Page 1.1-10 of44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 37.60 771.91 39.04 770.47 45.06 764.45 49.11 760.40 50.49 759.02 61.30 758.21 41.25 768.26 30.29 779.22 36.45 773.06 32.38 777.13 33.08 776.43 35.44 774.07 Prepared by/Date: fo;;_ ??f/1 4-Checked by/Date: /l.t;, A, I "/ 1 'I NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-417U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 11:05 775.03 10/1/2013 9:12 775.03 10/9/2013 9:41 775.03 10/26/2013 13:15 775.03 11/5/2013 14:14 775.03 OW-417U 11/12/2013 11:03 775.03 11/23/2013 12:05 775.03 12/9/2013 10:55 775.03 12/20/2013 12:37 775.03 1/13/2014 11:17 775.03 1/16/2014 13:13 775.03 2/18/2014 9:34 775.03 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatetiJmcJtf~l'IW!~ttJiltir~~t#t~EiJ.l4 CRP-1112.16 Page 1.1-11 of44
- WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 28.06 746.97 28.26 746.77 28.62 746.41 29.10 745.93 29.45 745.58 29.94 745.09 30.73 744.30 26.88 748.15 27.64 747.39 25.85 749.18 25.61 749.42 27.32 747.71 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-417L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 11:02 775.71 10/1/2013 9:16 775.71 10/9/2013 9:43 775.71 10/26/2013 13:22 775.71 11/5/2013 14:16 775.71 OW-417L 11/12/2013 11:05 775.71 11/23/2013 12:07 775.71 12/9/2013 10:58 775.71 12/20/2013 12:31 775.71 1/13/2014 11:18 775.71 1/16/2014 13:19 775.71 2/18/2014 9:40 775.71 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watectm~~fi!>~W~oTtiF&v~4 CRP-1112.16 Page 1.1-12 of44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 25.30 750.41 25.54 750.17 25.82 749.89 26.56 749.15 26.97 748.74 27.27 748.44 27.94 747.77 27.10 748.61 25.60 750.11 23.43 752.28 23.18 752.53 23.84 751.87 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-423U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 15:31 800.21 10/1/2013 9:02 800.21 10/9/2013 11:35 800.21 10/26/2013 8:33 800.21 11/5/2013 13:21 800.21 OW-423U 11/12/2013 10:07 800.21 11/23/2013 11:16 800.21 12/9/2013 14:13 800.21 12/20/2013 11:20 800.21 1/13/2014 11:41 800.21 1/16/2014 1.1:51 800.21 2/18/2014 14:08 800.21 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Wat~liMIII~~Dini"ER~Ilt ~.04 CRP-1112.16 Page 1.1-13 of44 WATER LEVEL DEPTH (ft) 38.78 39.75 39.85 41.72 42.28 42.92 41.53 34.61 39.29 37.93 38.21 38.70 WATER LEVEL ELEVATION (ft) 761.43 760.46 760.36 758.49 757.93 757.29 758.68 765.60 760.92 762.28 762.00 761.51 Prepared by/Date: --/;1-Q{)_y_;p_d)_(,_,--,-/._;_tf--,-
Checked by/Date: §4 :i! / "P /tc.f NOTES
OBSERVATION DATE WELLID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 11/5/2013 OW-423L 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1/13/2014 1/16/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW-423L CLINCH RIVER SMR PROJECT TIME 15:30 8:59 11:34 8:32 13:24 10:14 11:14 14:17 11:15 11:42 11:57 14:12 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION(ft) 801.13 29.53 771.60 801.13 31.48 769.65 SOL 13 35.24 765.89 801.13 37.41 763.72 801.13 38.28 762.85 801.13 39.00 762.13 801.13 37.77 763.36 801.13 20.84 780.29
. 801.13 26.89 774.24 801.13 24.48 776.65 801.13 23.97 777.16 801.13 25.90 775.23
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum Is NAVD 88
- 3. See Appendix E.1 for well construction details.
<7&--J- ~/t /;tJ-NOTES Prepared by/Date: ____,/,..--c',-----::,.._.-
Checked by/Date: @A-
~ / '5/ 1 Cf WatedfiWc~iPb~Wflffi~'Q11~EiJ.l4 CRP-1112. 16 Page 1.1-14 of 44
OBSERVATION DATE WELL ID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 11/5/2013 OW-423D 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1/13/2014 1/16/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- LONG-TERM OBSERVATION WELL OW*423D CLINCH RIVER SMR PROJECT TIME 15:28 8:57 11:32 8:30 13:26 10:18 11:12 14:25 11:10 11:44 12:03 14:15 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION {ft) 802.86 27.34 775.52 802.86 27.09 775.77 802.86 27.98 774.88 802.86 30.80 772.06 802.86 31.67 771.19 802.86 32.05 770.81 802.86 30.16 772.70 802.86 20.58 782.28 802.86 20.44 782.42 802.86 17.95 784.91 802.86 16.50 786.36 802.86 20.46 782.40
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88 NOTES
- 3. See Appendix E.1 for well construction details.
Prepared by/Date:
Checked by/Date:
}tl~ ~ ;, /1 (}_
~4-7/1/ 1r Waternm~H=RIW!i'rrna~ftle~~e!'-'! 4 CRP-1112.16 Page 1.1-15 of44
APPENDIX 1.1 -Manual Water Level Readings-No Change for Rev. 4 1.1.2 Other Observation Wells Clinch River Data Report Rev. 4 CRP-1112.16 Page 1.1-16 of44 a me
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT*PW CLINCH RIVER SMR PROJECT OBSERVATION DATE TIME WELL ID 11/5/2013 13:33 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 804.03 64.32 739.71 NOTES 11/12/2013 NM 804.03 NM NM Well is secured with drill rig. Not accessible at this time.
11/23/2013 11:22 804.03 PT*PW 12/9/2013 14:44 804.03 12/20/2013 11:05 804.03 1/13/2014 11:50 804.03 1/16/2014 12:20 804.03 2/18/2014 14:27 804.03 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction.details.
WatetiJm~lfRJWiJlrtilftirftleJmtlt~E!.J! 4 CRP-1112.16 Page 1.1-17 of 44 66.73 737.30 62.67 741.36 65.62 738.41 64.64 739.39 65.02 739.01 66.28 737.75
~b//;4-Prepared by/Date: _,/"=v-=-**---=---,---r Checked by/Date: @,... ~ / "f, /
1 '/
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT-OW-U1 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 11/5/2013 13:18 801.52 11/12/2013 10:02 801.52 11/23/2013 11:07 801.52 PT*OW-U1 12/9/2013 14:10 801.52 12/20/2013 11:51 801.52 1/13/2014 11:40 801.52 1/16/2014 11:43 801.52 2/18/2014 14:04 801.52 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum Is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watecmvt:h~f>~ffi3~Mt~v94 CRP-1112.16 Page 1.1-18 of44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION {ft) 60.41 741.11 61.44 740.08 63.14 738.38 50.78 750.74 60.92 740.6 58.36 743.16 58.36 743.16 59.42 742.1 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT-OW-L 1 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WATER LEVEL WATER LEVEL WELL ID ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 11/5/2013 13:17 803.13 42.50 760.63 11/12/2013 10:04 803.13 43.42 759.71 11/23/2013 11:09 803.13 41.87 761.26 PT-OW-L1 12/9/2013 14:04 803.13 17.46 785.67 12/20/2013 11:53 803.13 29.06 774.07 1/13/2014 11:37 803.13 22.95 780.18 1/16/2014 11:37 803.13 23.35 779.78 2/18/2014 14:00 803.13 28.54 774.59 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
NOTES OAJ oJ; let-Prepared by/Date: --;;/..--::::v;----:-----:~--.
Checked by/Date: {UA-
~ / 1>/1 </
WatedJiWI!tFR~flOOfifl~'ffi\\fR>t¥v9 4 CRP-1112.16 Page 1.1-19 of44
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT-OW-U2 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13-1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 11/5/2013 13:14 805.31 11/12/2013 9:58 805.31 11/23/2013 11:04 805.31 PT-OW-U2 12/9/2013 14:00 805.31 12/20/2013 11:58 805.31 1/13/2014 11:33 805.31 1/16/2014 11:22 805.31 2/18/2014 13:56 805.31 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watecii1Wt!~fl~ff~ffi\\lftle'v94 CRP-1112.16 Page 1.1-20 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 60.34 744.97 61.36 743.95 62.53 742.78 54.91 750.40 54.82 750.49 52.22 753.09 52.07 753.24 53.34 751.97 NOTES
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT*OW*L2 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE, AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WATER LEVEL WATER LEVEL WELL ID ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 11/5/2013 13:13 804.32 42.88 761.44 11/12/2013 9:55 804.32 43.60 760.72 11/23/2013 11:03 804.32 42.47 761.85 PT*OW*L2 12/9/2013 13:54 804.32 12.83 791.49 12/20/2013 12:04 804.32
.28.19 776.13 1/13/2014 11:32 804.32 20.57 783.75 1/16/2014 11:30 804,32 21.47 782.85 2/18/2014 13:52 804.32 27.88 776.44 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
NOTES Prnporn< by/D,.; !;/
3
~ /7 Checked by/Date:
~ '3 "Z
1 'I Wateouweti=R~PmlflflMj>mlt:IRE!v9 4 CRP-1112. 16 Page 1.1-21 of44
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT-OW-U3 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 11/5/2013 13:28 801.65 11/12/2013 10:22 801.65 11/23/2013 11:18 801.65 PT*OW-U3 12/9/2013 14:38 801.65 12/20/2013 11:25 801.65 1/13/2014 11:46 801.65 1/16/2014 12:08 801.65 2/18/2014 14:22 801.65 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watec!JJWI!~f'l!>~fifl~M\\FR\\¥v94 CRP-1112.16 Page 1.1-22 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 39.40 762.25 39.96 761.69 39.22 762.43 25.90 775.75 28.43 773.22 25.77 775.88 25.75 775.90 28.77 772.88 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- PUMPING TEST OBSERVATION WELL PT-OW-L3 CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 11/5/2013 13:30 803.12 11/12/2013 10:24 803.12 11/23/2013 11:19 803.12 PT-OW-L3 12/9/2013 14:34 803.12 12/20/2013 11:29 803.12 1/13/2014 11:47 803.12 1/16/2014 12:14 803.12 2/18/2014 14:18 803.12 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Wat£Wueh!RiwioiDiita~n R&v.04 CRP-1112.16 Page 1.1-23 of 44 WATER LEVEL DEPTH (ft) 59.20 59.32 59.82 58.04 58.78 57.76 57.74 58.16 WATER LEVEL ELEVATION (ft) 743.92 743.80 743.30 745.08 744.34 745.36 745.38 744.96 Prepared by/Date: --,~;;---:---._-
Checked by/Date:_.___:::----"'----'-+
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*401U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 15:49 82D.48 10/1/2013 9:24 820.48 10/9/2013 9:20 820.48 10/26/2013 12:55 820.48 OW*401U 11/5/2013 13:44 820.48 11/12/2013 10:41 820.48 11/23/2013 11:47 820,48 12/9/2013 11:53 820.48 12/20/2013 12:13 820.48 1/13/2014 10:58 820.48 2/18/2014 9:54 820.48 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
. Watet'tfWc~lpr~ur~'Oo/t~i¥J.l4 CRP-1112.16 Page 1.1-24 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 9.52 810.96 9.96 810.52 10.29 810.19 10.54 809.94 10.66 809.82 10.70 809.78 10.85 809.63 7.34 813.14 9.85 810.63 8.88 811.60 9.62 810.86 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*401L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 15:45 820.57 10/1/2013 9:20 820.57 10/9/2013 9:18 820.57 10/26/2013 12:53 820.57 OW-401L 11/5/2013 13:41 820.57 11/12/2013 10:40 820.57 11/23/2013 11:44 820.57 12/9/2013 11:56 820.57 12/20/2013 12:12 820.57 1/13/2014 10:57 820.57 2/18/2014 9:52 820.57 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watecttme~fl~fff~oEf\\lj!&'v94 CRP-1112.16 Page 1.1-25 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 37.08 783.49 38.86 781.71 40.14 780.43 41.90 778.67 42.41 778.16 42.37 778.20 39.96 780.61 28.82 791.75 33.28 787.29 25.02 795.55 31.88 788.69 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-401D CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 9:20 821.28 10/1/2013 9:28 821.28 10/9/2013 9:22 821.28 10/26/2013 12:57 821.28 OW-401D 11/5/2013 13:46 821.28 11/12/2013 10:42 821.28 11/23/2013 11:49 821.28 12/9/2013 12:01 821.28 12/20/2013 12:14 821.28 1/13/2014 10:58 821.28 2/18/2014 9:56 821.28 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
watedfmctm~P'Wrae~ol1~1¥J.l4 cRP-1112.16 Page 1.1-26 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 39.61 781.67 38.58 782.70 40.31 780.97 43.95 777.33 48.40 772.88 44.19 777.09 40.79 780.49 34.41 786.87 40.05 781.23 26.95 794,33 29.84 791.44 NOTES
OBS~RVATION DATE WELLID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 OW-415U 11/5/2013 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1/13/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-415U CLINCH RIVER SMR PROJECT TIME 14:33 11:26 10:55 13:45 14:50 11:28 12:37 9:20 12:58 8:37 9:04 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 787.22 28.42 758.80 787.22 29.41 757.81 787.22 31,13 756.09 787.22 32.01 755.21 787.22 32.33 754.89 787.22 32.44 754.78 787.22 30.84 756.38 787.22 15.20 772.02 787.22 22.82 764.40 787.22 20.00 767.22 787.22 24.00 763.22
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88 NOTES
- 3. See Appendix E.1 for well construction details.
Prepared by/Date: -&4':..1 ° Jr /I (-..
Checked by/Date: tf 4- "3/1 / 1'/
Watedtmch91ti'<il!ifl~~fae~Ol\\fk't¥v~ 4 CRP-1112.16 Page 1.1-27 of 44
OBSERVATION DATE WELL ID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 OW-415L 11/5/2013 11/12/2013 11/23/2013 12/9/2013 12/20/2013 GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-415L CLINCH RIVER SMR PROJECT TIME 14:36 11:30 10:58 13:49 14:53 11:30 12:39 9:23 12:59 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION {ft)
DEPTH {ft)
ELEVATION {ft) 786.75 22.92 763.83 786.75 21.73 765.02 786.75 21.29 765.46 786.75 21.35 765.40 786.75 21.49 765.26 786.75 21.56 765.19 786.75 20.62 766.13 786.75 14.84 771.91 786.75 15.88 770.87 NOTES 1/13/2014 NA 786.75 NM NM Not Measured. TVA sampling well. Pump stuck in well.
2/18/2014 9:02 787.75 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WaterCfjW(!IfRY~~<rro"Ma~~~¥!-IR 4 CRP-1112.16 Page 1.1-28 of 44 18.07 769.68 Prepared by/Date:
Checked by/Date:
OBSERVATION DATE WELL ID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 OW-416U 11/5/2013 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1113/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-416U CLINCH RIVER SMR PROJECT TIME 14:28 11:12 10:28 13:41, 14:45 11:22 12:34 9:31 12:56 8:36 9:05 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 812.82 71.38 741.44 812.82 71.78 741.04 812.82 72.76 740.06 812.82 72.93 739.89 812.82 73.08 739.74 812.82 73.97 738.85 812.82 75.60 737.22 812.82 66.89 745.93 812.82 74.32 738.50 812.82 70.20 742.62 812.82 73.58 739.24
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
NOTES
~
- '!;,It/;¢..
Prepared by/Date: --~.---:--=-::-=-
Checked by/Date: ~
3/ '??/ 11 wateouw~:tffl~P~Ifpffilj)011mv?4 CRP-1112.16 Page 1.1-29 of 44
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*416L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 9/24/2013 14:22 812.73 10/1/2013 11:16 812.73 10/9/2013 10:26 812.73 10/26/2013 13:38 812.73 OW*416L 11/5/2013 14:43 812.73 11/12/2013 11:20 812.73 11/23/2013 12:32 812.73 12/9/2013 9:35 812.73 12/20/2013 12:55 812.73 1/13/2014 8:35 812.73 2/18/2014 9:07 812.73 Notes:
- 1. Depths referenc~d to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatecJmy~h~if>I!>§Fae~ol11Jl&¥v?4 CRP-1112.16 Page 1.1-30 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 71.25 741.48 71.65 741.08 72.60 740.13 72.81 739.92 72.94 739.79 73.83 738.90 75.44 737.29 67.17 745.56 74.17 738.56 70.13 742.60 73.43 739.30 Prepared by/Date:
Checked by/Date:
NOTES
OBSERVATION DATE WELL ID 9/24/2013 10/1/2013 10/9/2013 10/26/2013 OW-418U 11/5/2013 11/12/2013 11/23/2013 12/9/2013 12/20/2013 1/13/2014 2/18/2014 Notes:
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-418U CLINCH RIVER SMR PROJECT TIME 13:54 11:03 9:54 13:24 14:23 11:16 12:21 9:46 12:50 8:29 9:12 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION {ft) 812.94 61.98 750.96 812.94 61.92 751.02 812.94 62.33 750.61 812.94 63.56 749.38 812.94 64.41 748.53 812.94 65.11 747.83 812.94 65.77 747.17 812.94 51.54 761.40 812.94 58.35 754.59 812.94 55.80 757.14 812.94 57.58 755.36
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
(}L\\ ~ ~~. ;; J.
NOTES Prepared by/Date: !!..17' 1 / -
Checked by/Date: {lM-
~~~ / 1'/
Watectlil'~~fl~Wf~M\\Fffi¥v94 CRP-1112.16 Page 1.1-31 of44
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*418L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 13:55 814.41 10/1/2013 10:58 814.41 10/9/2013 9:50 814.41 10/26/2013 13:25 814.41 OW"418L 11/5/2013 14:25 814.41 11/12/2013 11:18 814.41 11/23/2013 12:23 814.41 12/9/2013 9:41 814.41 12/20/2013 12:53 814.41 1/13/2014 8:30 814.41 2/18/2014 9:10 814.41 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatedJiWI!tFRIV\\¥ili01RWR\\!~m\\~J.l 4 CRP-1112.16 Page 1.1-32 of 44 WATER LEVEL DEPTH (ft) 66.20 67.53 68.64 69.45 70.10 70.87 71.43 63.85 62.34 61.38 62.98 WATER LEVEL ELEVATION (ft) 748.21 746.88 745.77 744.96 744.31 743.54 742.98 750.56 752.07 753.03 751.43 Prepared by/Date:--#-.,.--------,
Checked by/Date: ---"--""...!.:L~~~,_
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-419U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 13:33 803.13 10/1/2013 9:02 803.13 10/9/2013 9:37 803.13 10/26/2013 13:09 803.13 OW*419U 11/5/2013 14:04 803.13 11/12/2013 10:52 803.13 11/23/2013 12:01 803.13 12/9/2013 11:34 803.13 12/20/2013 9:18 803.13 1/13/2014 11:03 803.13 2/18/2014 9:23 803.13 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watetitm~'ti=RIWillrrFcRW~j>mltfRI!J.l 4 CRP-1112.16 Page 1.1-33 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 45.73 757.40 49.94 753.19 53.55 749.58 54.51 748.62 54.72 748.41 54.82 748.31 51.97 751.16 35.43 767.70 43.37 759.76 39.42 763.71 44.35 758.78 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-419L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECTNO. 6468*13-1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 13:32 802.72 10/1/2013 9:07 802.72 10/9/2013 9:35 802.72 10/26/2013 13:11 802.72 OW-419L 11/5/2013 14:06 802.72 11/12/2013 10:58 802.72 11/23/2013 11:59 802.72 12/9/2013 11:30 802.72 12/20/2013 9:20 802.72 1/13/2014 11:04 802.72 2/18/2014 9:25 802.72 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Water<!;n~fi1Ri~D>af§cR~If'Rel9. 4 CRP-1112.16 Page 1.1-34 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 46.32 756.40 49.83 752.89 53.04 749.68 54.00 748.72 54.20 748.52 54.27 748.45 51.65 751.07 39.15 763.57 43.95 758.77 40.86 761.86 44.72 758.00 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-420U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 13:43 805.70 10/1/2013 9:56 805.70 10/9/2013 9:29 805.70 10/26/2013 13:04 805.70 OW-420U 11/5/2013 13:54 805.70 11/12/2013 10:50 805.70 11/23/2013 11:53 805.70 12/9/2013 11:38 805.70 12/20/2013 12:19 805.70 1/13/2014 11:01 805.70 2/18/2014 9:49 805.70 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
- 4. NM = Not Measured.
Watel{}fii'l'f!tfRYvl¥r'l:JiitrafRii!~IW14 CRP-1112.16 Page 1.1-35 of 44 WATER LEVEL DEPTH (ft) 46.83 47.71 48.66 DRY DRY DRY 47.09 45.12 46.82 46.66 46.57 WATER LEVEL NOTES ELEVATION {ft) 758.87 757.99 757.04 NM 49.35 Termination Depth. Brown sediment on probe.
NM 49.33 Termination Depth. Brown sediment on probe.
NM 49.35 Termination Depth. Tagged total depth.
758.61 760.58 758.88 759.04 759.13 Prepared by/Date: --#r f}()_:-'J_'--::,_:-~~--:-/-/t_/tl Checked by/Date: &If 1l/ $/1 </
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*420L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 13:45 806.15 10/1/2013 9:47 806.15 10/9/2013 9:27 806.15 10/26/2013 13:02 806.15 OW-420L 11/5/2013 13:56 806.15 11/12/2013 10:51 806.15 11/23/2013 11:55 806.15 12/9/2013 11:43 806.15 12/20/2013 12:17 806.15 1/13/2014 11:00 806.15 2/18/2014 9:47 806.15 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD.88
- 3. See Appendix E.1 for well construction details.
WateOin'eltRMi~IDlih!S~Mt IRMIP4 CRP-1112.16 Page 1.1-36 of 44 WATER LEVEL DEPTH (ft) 64.02 64.77 65.18 65.14 65.49 66.10 69.56 61.18 66.16 60.72 64.38 WATER LEVEL ELEVATION (ft) 742.13 741.38 740.97 741.01 740.66 740.05 736.59 744.97 739.99 745.43 741.77 Prepared by/Date: -h'c....------:-----,.-
Checked by/Date: -=---~'---"'+--<-
NOTES
.~
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-421U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 9/24/2013 14:09 808.27 10/1/2013 10:43 808.27 10/9/2013 10:01 808.27 10/26/2013 13:30 808.27 OW-421U 11/5/2013 14:35 808.27 11/12/2013 11:14 808.27 11/23/2013 12:30 808.27 12/9/2013 11:13 808.27 12/20/2013 12:46 808.27 1/13/2014 8:19 808.27 2/18/2014 9:15 808.27 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum Is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watedlft'l'~tFRtWfl~MJ~Ilffl:IR\\¥v94 CRP-1112.16 Page 1.1-37 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 55.04 753.23 53.91 754.36 53.79 754.48 54.15 754.12 54.13 754.14 54.09 754.18 54.12 754.15 54.04 754.23 53.82 754.45 53.72 754.55 53.82 754.45 Prepared by/Date:
Checked by/Date:
NOTES
OBSERVATION DATE WELLID 9/24/2013 10/1/2013 GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW*421L CLINCH RIVER SMR PROJECT TIME 14:02 10:38 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 807,81 98.54 709.27 807.81 70.61 737.20 NOTES 10/8/2013 9:05 807.81 61.15 746.66 Water level obtained between slug tests.
10/26/2013 13:31 807.81 OW*421L 11/5/2013 14:33 807.81 11/12/2013 11:13 807.81 11/23/2013 12:28 807.81 12/9/2013 11:17 807.81 12/20/2013 12:45 807.81 1/13/2014 8:18 807.81 2/18/2014 9:17 807.81 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
WatedJIW~tfRlWf>~f§'~m\\fRI¥v94 CRP-1112.16 Page 1.1-38 of 44 59.89 59.77 59.91 119.47 63.13 58.36 57.38 57.55 747.92 748.04 747.90 688.34 Well still recovering after water quality samplln>J.
744.68 749.45 750.43 750.26 Prep a red by/Date: --H---:--:::;;-.-:-------,
Checked by/Date: ~-----"':::....!.-::c.t--___:__,t-
OBSERVATION DATE WELL ID 9/24/2013 10/1/2013 GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-421D CLINCH RIVER SMR PROJECT TIME 14:11 10:23 OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 805.20 176.16 629.04 805.20 135.66 669.54 NOTES 10/8/2013 9:06 805.20 102.07 703.13 Water level obtained between slug tests.
10/26/2013 13:33 805.20 OW-421D 11/5/2013 14:31 805.20 11/12/2013 11:11 805.20 11/23/2013 12:26 805.20 12/9/2013 11:22 805.20 12/20/2013 12:44 805.20 1/13/2014 8:20 805.20 2/18/2014 9:19 805.20 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Water(!;fi'ffll:fiiPM~i§Mil~rf'~jf. 4 CRP-1112.16 Page 1.1-39 of 44 72.01 65.50 63.29 61.80 61.18 60.00 86.04 60.50 733.19 739.70 741.91 743.40 744.02 745.20 719.16 Water /eve/lowered due to TVA sampling 744.70
/Y>JL 44/tt~-
Prepared by/Date: ?;P'I"'
~*,...,-( d ~ "'.!/ G Checked by/Date: -"-'--'"'"-'--":!fl.L.L.v_,v"D--'-'r
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-428U CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELLID ELEVATION (ft) 11/5/2013 15:10 807.78 11/12/2013 12:16 807.78 OW-428U 11/23/2013 7:54 807.78 12/9/2013 13:36 807.78 12/20/2013 9:55 807.78 1/13/2014 9:10 807.78 2/18/2014 12:09 807.78 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Waterdfiffl!lfRY~~'rro"Jfa:Re~I?\\P. 4 CRP-1112.16 Page 1.1-40 of 44 WATER LEVEL DEPTH (ft) 42.51 42.84 34.65 17.51 22.35 16.34 19.35 WATER LEVEL ELEVATION (ft) 765.27 764.94 773.13 790.27 785.43 791.44 788.43 Prepared by/Date: Jf*.} o)., lttJ.-
Checked by/Date: /Z.Jhf-
~ / ~~ 1 'I NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-428L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 11/12/2013 12:13 807.06 11/23/2013 7:52 807.06 OW-428L 12/9/2013 13:39 807.06 12/20/2013 9:56 807.06 1/13/2014 9:11 807.06 2/18/2014 12:07 807.06 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Waternm~tf'R~P'D1iUilR\\!IWftltfRe!~ 4 CRP-1112.16 Page 1.1-41 of44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 48.23 758.83 24.85 782.21 19.85 787.21 28.64 778.42 17.60 789.46 16.92 790.14 Prepared by/Date:
Checked by/Date:
NOTES
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-428D CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 11/12/2013 12:10 807.03 11/23/2013 7:50 807.03 12/9/2013 13:44 807.03 12/11/2013 8:48 807.03 12/11/2013 9:23 807.03 12/12/2013 14:35 807.03 OW-428D 12/13/2013 9:15 807.03 12/17/2013 NM 807.03 12/18/2013 9:11 807.03 12/20/2013 13:23 807.03 1/9/2014 9:20 807.03 1/13/2014 NM 807.03 1/16/2014 14:14 807.03 2/18/2014 12:04 807.03 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
- 4. NM = Not Measured
- 5. Well has very slow recovery.
WatecltflV~H"Ri\\1E!ilrrF.ftrcll~~ifRe~. 4 CRP-1112.16 Page 1.1-42 of 44 WATER LEVEL WATER LEVEL NOTES DEPTH (ft)
ELEVATION (ft) 177.22 629.81 Well drawn down during development.
45.50 761.53 Well recoverinQ from development.
11.05 795.98 9.53 797.50 9.65 797.38 Transducer dejlth reset.
8.97 798.06 8.73 798.30 NM NM TVA sampling well.
32.82 774.21 Transducer reinstalled after TVA samplinQ. Well recoverinq.
27.39 779.64 Well recovering.
18.37 788.66 Well recovering.
NM NM Not measured. Falling head test in prooress.
11.43 795.60 9.80 797.23 Prepared by/Date:
Checked by/Date:
OBSERVATION DATE WELLID 11/12/2013 11/23/2013 OW-429U 12/9/2013 GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-429U CLINCH RIVER SMR PROJECT TIME 11:40 12:59 13:23 OAK RIDGE, ROANp COUNTY, TENNESSEE AMEC PROJECT NO. 6468*13*1072 REF. POINT WATER LEVEL WATER LEVEL ELEVATION (ft)
DEPTH (ft)
ELEVATION (ft) 799.17 40.47 758.70 799.17 37.07 762.10 799.17 32.28 766.89 NOTES 12/20/2013 9:33 799.17 30.95 768.22 TVA sampling welt. Pump in well overniaht.
1/13/2014 8:54 799.17 2/18/2014 8:53 799.17 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watec~ER!I'iflioi!>§Rt~Ttm¥v?4 CRP-1112.16 Page 1.1-43 of.44 30.97 768.20 32.28 766.89
GROUNDWATER LEVEL
SUMMARY
- OBSERVATION WELL OW-429L CLINCH RIVER SMR PROJECT OAK RIDGE, ROANE COUNTY, TENNESSEE AMEC PROJECT NO. 6468-13-1072 OBSERVATION DATE TIME REF. POINT WELL ID ELEVATION (ft) 11/12/2013 11:42 799.49 11/23/2013 12:56 799.49 OW-429L 12/9/2013 13:28 799.49 12/20/2013 9:36 799.49 1/13/2014 8:55 799.49 2/18/2014 8:55 799.49 Notes:
- 1. Depths referenced to mark on Top of Casing.
- 2. Survey Vertical Datum is NAVD 88
- 3. See Appendix E.1 for well construction details.
Watel(}fill;~ti=RIW!Prriat!ll~jwftitfREiv9 4 CRP-1112.16 Page 1.1-44 of 44 WATER LEVEL WATER LEVEL DEPTH (ft)
ELEVATION (ft) 162.64 636.85 161.00 638.49 159.30 640.19 158.20 641.29 160.00 639.49 156.77 642.72 Prepared by/Date:
Checked by/Date:
NOTES