Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix G.2 - Pages 88-91
ML19030B017
Person / Time
Site: Clinch River
Issue date: 01/18/2019
From: James Shea
Tennessee Valley Authority
To:
Office of New Reactors
Fetter A
References
TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.6, CRN.P.PART08, CRN.P.PART08.2
Download: ML19030B017 (4)


Text

a me Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compress ion ASTM 07012*10 Project Name: Clinch River SMR Project Number: 6468-13-1072 Tested By: Mike Hamilton l'llt/

Test Date: _1_12_1'--12_0_14 ____

-'+

!f_..~I/JL{

Reviewed By: Allen Cottingham (lPrt Review Date: 1/29/2014 Vll*ll\\

Rock Type Moisture Condition Specimen Diameter, (in)

Specimen Length, (in)

Length/Diameter Ratio Sample No.: L7-27 H Boring No.: MP-421 Run. No.: N/A Sample Depth (ft): 225.6*226.2 Page 1 of2 (See boring log)

Laboratory Air-Dry 2.39 5.14 2.2 Specimen Conforms with Dimensional Requirements?

No<11 Yi.s

"' g V>

~

~

As-Tested Unit Weight, (pcf)

Loading Rate (lb/sec)

Test Duration to Failure, (min)

Uniaxial Compressive Strength, (psi)

Type of Break Young's Modulus, (psi)

Poisson's Ratio

-14,000

-12,000

-10.000

  • 8,000 -

I

  • 6,000 ---,-

-4,000

  • 2,000 0

0.0020 0.0010 0.0000 Lateral Strain ( + ),(In/In)

Comments:

.0.0010

~ t'15/tJ..-

160 t/

10.7 21,790 Columnar 11,290,000 0.30


1

--Average Adjusted Axial Strain (in/in)

--Average Adjusted Lateral Strain (in!ln)

.().0020 Axial Strain ( - ), (In/In]

  • 0.0030 Young's Modulus and Poisson's Ratio determined using linear least-squares or stress-strain data from 30% to 50%

or the uniaxial compressive strength (data points used are Indicated on the figure above).

Axial Strain is negative; Lateral Strain is positive. Load direction with respect to lithology: Vertical P> Specimen did not meet end flatness requirements or ASTM 04543-08. Authorization to proceed with test received from John Damm.

Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-88 of 91

a me Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Project Number: 6468-13-1072 Tested By: Mike Hamilton I11H Test Date: 1/21/2014 llH/11-l Reviewed By: Allen Cottingham rr\\lt(

Review Date:_1'-/2_9'-/2_0_14 _______ 1 -t. 1 Comments:

Specimen Prior to Testing

("MP-421 L7-27 H before test.jpg"):

Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-89 of 91 Sample No.: L7-27 H Boring No.: MP-421 Run. No.: N/A Sample Depth (ft): 225.6-226.2 Page 2 of 2 Specimen After Testing

("MP-421 L7-27 H after test.jpg"):

a me Elastic Moduli of Intact Rock Core Specimens in Uniaxial Compression ASTM 07012*1 0 Project Name: Clinch River SMR Project Number: 6468-13-1072 Tested By: Mike Hamilton mil Test Date: _1_12_1'-12_0_14 ____

_,1'+1~

1t/JI.(

Reviewed By: Allen Cottingham r

(~'ftC Review Date: 1/29/2014 1*11* 1~

Rock Type Moisture Condition Specimen Diameter, (in)

Specimen Length, (in)

Length/Diameter Ratio Specimen Conforms with Dimensional Requirements?

Sample No.: L7-31 BH Boring No.: MP-423 Run. No.: N/A Sample Depth (ft): 81.5-82.5 Page 1 of 2 (See boring Jog)

Laboratory Air-Dry 2.37 4.98 2.1 No 111 As-Tested Unit Weight, (pcf)

~l(;ip ~~

.e f!

u;

~

Loading Rate (lb/sec)

Test Duration to Failure, (min)

Uniaxial Compressive Strength, (psi)_

Type of Break Young's Modulus, (psi)

Poisson's Ratio

-8.000

  • 7.000

-6.000

-5.000

-4,000

-3,000

-2.000

-1,000 0

1.000 0.0010 0.0000

-0.0010

-0.0020 Lateral Strain (+), (In/In)

Comments:

-0.0030 160 4.7 6,960 Columnar 1,620,000 0.16

-- Average Adjusted Axial Strain (in/in)

--Average Adjusted Lateral Strain (in/in)

-0.0040 Axial Strain ( - ), (In/In)

Young's Modulus and Poisson's Ratio determined using linear least-sguares or stress-strain data from 40% to 60%

or the uniaxial compressive strenglh (data points used are Indicated on the figure above).

Axial Strain is negative; Lateral Strain is positive.

Load direction with respect to lithology: Vertical 1'1 Specimen did not meet End Flatness requirements or ASTM 04543-08. Authorization to proceed with test received from John Damm.

Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-90 of 91

-0.0050

a me Elastic Moduli of Intact Rock Core Specimens In Uniaxial Compression ASTM 07012-10 Project Name: Clinch River SMR Project Number: 6468-13-1072 Tested By: Mike Hamilton h1 /!

Test Date:....:1:..::/2:..:.1 :..::12:.::.0..:...14.:__ ____

~

1/..L!

~ ljltJ Reviewed By: Allen Cottingham

"~

Review Date: 1/29/2014

!"?I-tt{

Comments:

Specimen Prior to Testing

("MP-423 L7-31 BH before test.jpg"):

Clinch River Data Report Rev. 4 CRP-1112.16 Page G.2-91 of 91 Sample No.: L7-31 BH Boring No.: MP-423 Run. No.: N/A Sample Depth (ft): 81.5-82.5 Page 2 of2 Specimen After Testing

("MP-423 L7-31 BH after test (2).jpg"):