ML18348A252

From kanterella
Jump to navigation Jump to search
License Event Report 1977-012-00 Re Boric Acid Tank Leak
ML18348A252
Person / Time
Site: Palisades Entergy icon.png
Issue date: 02/22/1977
From: Hoffman D
Consumers Power Co
To: James Keppler
NRC/RGN-III
References
LER 1977-012-00
Download: ML18348A252 (2)


Text

consumers

  • Power company General Offices: 212 West Michigan Avenue, Jae February 22, 1977 Mail Sedion*

Docket Cler~

Mr James G Keppler Office of Inspection & Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - ER-77 BORIC ACID TP.NK LEAK

  • Attached is a reportable occurrence relating to leakage from a heater in boric acid tank T-53A at the Palisades Plant.

David P Hoffman Assistant Nuclear Licensing Administrator

  • fEB 2 4: 1977 2236

.J' {,. ~*

tllicENSEE EVENT REPORT . ,

Palisades dCJ~TROL BLOCK: l...._......__.l.___~......__._~I [PLEASE PRINT ALL REQUIRED INFORMATION]

1 6 LICENSEE LICENSE EVENT

~ NAME LICENSE NUMBER TYPE TYPE

~IMlrlPIAILl1I I olol-lol ol ololol-lolol l411l1l1l1I I o I 3 I 7 8 9 14 15 25 26 30 31 32 DOCKl;T NUMBER . EVENT DATE

  • REPORT DATE

@ElcoN'T f *I_*_ I I ol 51 ol-1ol21 sl sl lol2lolsl1l1I 1012121211111 7 8 57 5B 61 6B 69 74 75 BO EVENT DESCRIPTION lol2I I A routine inspection of the eves revealed that the tank heater, H68A, for the boric I 7 8 9 BO lol31 I acid tank, T-53A, was leaking. The tank was removed from s.ervice, the heater I 7 8 9 80 lol41 I replaced, and the tank placed back in service within the 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed by Section I 7 8 9 80 10151 I 3.2.3.b of the Palisades. Technical Specifications. (ER-77-12) I 7 8 9 80 lolsl 7 8 9 PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT CODE CODE COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION

@EllPlel ~ IHIEIAITIEIRI UrJ I eI 4 I 2 Io47I LKI 7 8 9 10 11 12 17 43 44 48 CAUSE DESCRIPTION lol0I I The heater leak was not a generic problem and is considered normal maintenance. I.

7 8 9 80 lolsl 7 8 9 80

~

~

s'----------------------------------.,-------------------------------------------------0~0 FACILITY METHOD OF STATUS  %*POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION 7

fill]

8 L..ci 9

l1lolol 10 12 13 NA I 44 UJ 45 r,,,.---~R~o~u~t~i~n~e_....I~n~sp~e~c~t~1~*o~n.:;..___________

46

.....,,..,,I 80 FORM OF ACTIVITY CONTENT rn RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE

~J l~J I. . ---"""NA---..____.,. NA 7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION II@ 1010101 ~ NA 7 . 8 .9 11 12 13 80 PERS.ONNEL INJURIES NUMBER DESCRIPTION EEJl010101- NA 7 8 9 11 12 80 PROBABLE CONSEQUENCES

.[ill] NA 7 8 9 80 LOSS OR DAMAGE TO FACILITY

[Ifil 7 8 9 w

TYPE 10 DESCRIPTION NA 80 PUBLICITY illZl8 9 NA 7 80

  • ADDITIONAL FACTORS NA 7 8 9 80

[Tifil 7 8 9 80