MONTHYEARML24022A1172024-01-23023 January 2024 Acceptance of Requested Licensing Action Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations ML24012A2422024-01-16016 January 2024 Acceptance of Requested Licensing Action License Transfer Request ML23236A0042023-12-27027 December 2023 Issuance of Amendment 274 Re Changes to Perm Defueled Emergency Plan and Perm Defueled Emergency Action Level Scheme ML23355A1242023-12-26026 December 2023 Withdrawal of an Amendment Request Re License Amendment Request to Revise License Condition to Eliminate Cyber Security Plan Requirements ML23192A0772023-12-26026 December 2023 Letter Exemption from the Requirements of 10 CFR 140.11(a)(4) Concerning Offsite Primary and Secondary Liability Insurance ML23191A5222023-12-22022 December 2023 Exemption Letter from the Requirements of 10 CFR 50.54(W)(1) Concerning Onsite Property Damage Insurance (EPID - L-2022-LLE-0032) ML23263A9772023-12-22022 December 2023 Exemption from Certain Emergency Planning Requirements and Related Safety Evaluation ML23354A2602023-12-21021 December 2023 Reference Simulator Inspection Request for Information L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 PNP 2023-030, License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations2023-12-14014 December 2023 License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations PNP 2023-035, Withdrawal of License Amendment Request - Revise License Condition to Eliminate Cyber Security Plan Requirements2023-12-12012 December 2023 Withdrawal of License Amendment Request - Revise License Condition to Eliminate Cyber Security Plan Requirements PNP 2023-028, Application for Order Consenting to Transfer of Control of License and Approving Conforming License Amendments2023-12-0606 December 2023 Application for Order Consenting to Transfer of Control of License and Approving Conforming License Amendments L-23-012, Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point2023-11-13013 November 2023 Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point ML23291A4402023-11-0303 November 2023 Acceptance of Requested Licensing Action Request for Exemption from 10 CFR 50.82(a)(2) to Support Reauthorization of Power Operations IR 05000255/20230032023-10-0404 October 2023 NRC Inspection Report No. 05000255/2023003(DRSS)-Holtec Decommissioning International, LLC, Palisades Nuclear Plant ML23275A0012023-10-0202 October 2023 Request for Withholding Information from Public Disclosure for Palisades Nuclear Plant PNP 2023-025, Request for Exemption from Certain Termination of License Requirements of 10 CFR 50.822023-09-28028 September 2023 Request for Exemption from Certain Termination of License Requirements of 10 CFR 50.82 PNP 2023-026, Pre-Submittal Meeting Presentation - Palisades Nuclear Plant License Transfer Application to Support Resumption of Power Operations2023-09-28028 September 2023 Pre-Submittal Meeting Presentation - Palisades Nuclear Plant License Transfer Application to Support Resumption of Power Operations PNP 2023-023, Special Report High Range Noble Gas Monitor Inoperable2023-08-0909 August 2023 Special Report High Range Noble Gas Monitor Inoperable ML23215A2302023-08-0303 August 2023 Notice of Organization Change - Chief Nuclear Officer IR 05000255/20230022023-07-19019 July 2023 NRC Inspection Report 05000255/2023002 DRSS-Holtec Decommissioning International, LLC, Palisades Nuclear Plant ML23087A0362023-05-0202 May 2023 PSDAR Review Letter ML23117A2172023-05-0101 May 2023 Safety Evaluation for Quality Assurance Program Manual Reduction in Commitment PNP 2023-018, 2022 Annual Non-Radiological Environmental Operating Report2023-04-25025 April 2023 2022 Annual Non-Radiological Environmental Operating Report L-23-004, HDI Annual Occupational Radiation Exposure Data Reports - 20222023-04-24024 April 2023 HDI Annual Occupational Radiation Exposure Data Reports - 2022 PNP 2023-007, and Big Rock Point, 2022 Annual Radioactive Effluent Release and Waste Disposal Reports2023-04-19019 April 2023 and Big Rock Point, 2022 Annual Radioactive Effluent Release and Waste Disposal Reports PNP 2023-008, 2022 Radiological Environmental Operating Report2023-04-18018 April 2023 2022 Radiological Environmental Operating Report L-23-003, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-31031 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations PNP 2023-002, 6 to Updated Final Safety Analysis Report2023-03-31031 March 2023 6 to Updated Final Safety Analysis Report ML23088A0382023-03-29029 March 2023 Stations 1, 2, & 3, Palisades Nuclear Plant, and Big Rock Point - Nuclear Onsite Property Damage Insurance PNP 2023-006, Report of Changes to Security Plan, Revision 202023-03-29029 March 2023 Report of Changes to Security Plan, Revision 20 PNP 2023-012, Presentation on Regulatory Path to Reauthorize Power Operations2023-03-16016 March 2023 Presentation on Regulatory Path to Reauthorize Power Operations ML23038A0982023-03-15015 March 2023 Request for Withholding Information from Public Disclosure ML23095A0642023-03-14014 March 2023 American Nuclear Insurers, Notice of Cancellation Rescinded PNP 2023-001, Regulatory Path to Reauthorize Power Operations2023-03-13013 March 2023 Regulatory Path to Reauthorize Power Operations PNP 2023-004, Report of Changes to Palisades Nuclear Plant Technical Specification Bases2023-03-0808 March 2023 Report of Changes to Palisades Nuclear Plant Technical Specification Bases PNP 2023-005, Response to Palisades Nuclear Plant - Request for Additional Information Related to the Post-Shutdown Decommissioning Activities Report2023-03-0101 March 2023 Response to Palisades Nuclear Plant - Request for Additional Information Related to the Post-Shutdown Decommissioning Activities Report ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML23052A1092023-02-17017 February 2023 FEMA Letter to NRC, Proposed Commission Paper Language for Palisades Nuclear Plant Emergency Plan Decommissioning Exemption Request ML23032A3992023-02-0101 February 2023 Regulatory Path to Reauthorize Power Operations IR 05000255/20220032022-12-28028 December 2022 NRC Inspection Report No. 05000255/2022003(DRSS); 07200007/2022001 (Drss) Holtec Decommissioning International, LLC, Palisades Nuclear Plant L-22-042, Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.152022-12-14014 December 2022 Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.15 PNP 2022-037, Report of Changes to Security Plan, Revision 192022-12-14014 December 2022 Report of Changes to Security Plan, Revision 19 ML22321A2852022-11-17017 November 2022 LLC Master Decommissioning Trust Agreement for Palisades Nuclear Plant IR 05000255/20224012022-11-0909 November 2022 Decommissioning Palisades Nuclear Plant - Decommissioning Security Inspection Report 05000255/2022401 PNP 2022-036, Response to Request for Additional Information Regarding License Amendment Request for Proposed Permanently Defueled Emergency Plan and Permanently Defueled Emergency Action Level Scheme2022-11-0808 November 2022 Response to Request for Additional Information Regarding License Amendment Request for Proposed Permanently Defueled Emergency Plan and Permanently Defueled Emergency Action Level Scheme PNP 2022-035, International - Notification of Commitment Cancellations for Remaining Activities Related to Beyond-Design-Basis Seismic Hazard Reevaluations2022-11-0202 November 2022 International - Notification of Commitment Cancellations for Remaining Activities Related to Beyond-Design-Basis Seismic Hazard Reevaluations PNP 2022-024, Request for Exemption from 10 CFR 140.11(a)(4) Concerning Primary and Secondary Liability Insurance2022-10-26026 October 2022 Request for Exemption from 10 CFR 140.11(a)(4) Concerning Primary and Secondary Liability Insurance PNP 2022-026, Request for Exemption from 10 CFR 50.54(w)(1) Concerning Onsite Property Damage Insurance2022-10-26026 October 2022 Request for Exemption from 10 CFR 50.54(w)(1) Concerning Onsite Property Damage Insurance ML22292A2572022-10-25025 October 2022 Permanently Defueled Emergency Plan License Amendment RAI Letter 2024-01-23
[Table view] Category:Licensee Event Report (LER)
MONTHYEARML18344A4142018-12-10010 December 2018 LER 1979-037-00 for Palisades Nuclear Plant, Two Manual Three Inch Containment Isolation Valves in Bypass Line Were Discovered to Be Locked Open 05000255/LER-2017-0022017-07-17017 July 2017 Reactor Protection System Actuation While the Reactor was Shutdown, LER 17-002-00 for Palisades Regarding Reactor Protection System Actuation While the Reactor was Shutdown 05000255/LER-2017-0012017-05-24024 May 2017 Inadequate Protection from Tornado Missiles Identified Due to Nonconforming Design Conditions, LER 17-001-00 for Palisades Nuclear Plant Regarding Inadequate Protection from Tornado Missiles Identified Due to Nonconforming Design Conditions PNP 2014-100, Cancellation of Licensee Event Report (LER) 2004-002, Leak Indications Identified in Reactor Pressure Vessel Head Nozzle Penetrations2014-11-19019 November 2014 Cancellation of Licensee Event Report (LER) 2004-002, Leak Indications Identified in Reactor Pressure Vessel Head Nozzle Penetrations PNP 2011-009, Special Report of Inoperability of Main Steam Line Gross Gamma Activity Monitor2011-02-10010 February 2011 Special Report of Inoperability of Main Steam Line Gross Gamma Activity Monitor ML0726101822007-09-14014 September 2007 Cancellation of Licensee Event Report 07-003, Potential for Reduced Component Cooling Water Cooling Capability ML0609002832006-03-30030 March 2006 Cancellation of Licensee Event Report 05-006, Inoperable Containment Due to Containment Air Cooler Through-Wall Flaws ML18347B2971998-05-19019 May 1998 Submit, NPDES Notification Report, Incident No. Pal-98-05-NC138 for NPDES Permit No MI0001457 Re Difference from Daily Maximum Effluent Limitation for Facility ML18348A9021989-02-0707 February 1989 LER 1988-005-01 for Palisades, Inadequate Procedure Results in Valve Testing During Prohibited Conditions ML18346A2471981-06-19019 June 1981 LER 1981-020-00 for Palisades Nuclear Plant, Pcs Unidentified Leakage Greater than 1.0 Gpm ML18346A2481981-05-13013 May 1981 LER 1981-015-00 for Palisades Nuclear Plant, Safety Injection Tank Boron Concentration ML18346A2491981-02-20020 February 1981 LER 1981-005-00 for Palisades Nuclear Plant, Update - Inoperable Diesel Generator ML18346A2501981-02-19019 February 1981 LER 1981-007-00 for Palisades Nuclear Plant, Inoperable Auxiliary Feedwater Pump ML18346A2511981-01-26026 January 1981 LER 1981-002-00 for Palisades Nuclear Plant, Inadequate Mounting of DC Distribution Panel ML18346A2521981-01-16016 January 1981 LER 1981-001-00 for Palisades Nuclear Plant, During Charging of Station Batteries, Output Breakers of Both Batteries Were Inadvertently Opened for Approximately One Hour ML18346A2531981-01-14014 January 1981 LER 1980-046-00 for Palisades Nuclear Plant, Hydraulic Snubber Failure ML18346A2541981-01-0707 January 1981 LER 1980-045-00 for Palisades Nuclear Plant, Low Condensate Makeup Inventory ML18347A8141980-10-10010 October 1980 LER 1980-037-00 for Palisades Nuclear Plant, Pipe Support Sway Struts Identified to Have the Potential of the Bushing Becoming Loose And/Or Disengaged from the Clamp End of the Sway Strut ML18347A8461980-08-27027 August 1980 License Event Report 1980-027-00 Re Gaseous Release, Extended Due Date of Reporting by Region III on 8/26/1980 ML18347A8471980-08-12012 August 1980 License Event Report 1980-024-00 Re Containment High Radiation Monitor ML18347A8481980-08-0808 August 1980 License Event Report 1980-023-00 Re Containment High Radiation Monitor ML18347A8491980-08-0808 August 1980 License Event Report 1980-022-00 Re Inoperable Nuclear Instrumentation ML18347A8501980-08-0606 August 1980 License Event Report 1980-021-00 Re Misaligned Containment Sump Valve ML18347A8521980-07-29029 July 1980 License Event Report 1980-020-00 Re Misaligned Control Rod ML18347B2071980-06-19019 June 1980 Licensee Event Report 80-018 Regarding Oil Level in Snubber No. 2 Found to Be Less than Zero During Routine Testing of Hydraulic Snubbers ML18347B2081980-06-13013 June 1980 Licensee Event Reports 80-014, 80-015, and 80-016 Regarding Oil Level in Snubbers No. 5, 9, and 7 Were Found to Be Less than Zero During Routine Testing of Hydraulic Snubbers ML18347B2091980-05-15015 May 1980 Licensee Event Report 80-012 Regarding Bottom Half of the Barrier for Fire Penetration HO-12 Was Missing During Inspection of Fire Barriers ML18347B2101980-05-14014 May 1980 License Event Report 1980-011-00 Re Improper Return-to-Service of Porv'S ML18348A9071980-05-12012 May 1980 Submittal of LER 1980-006-00 Purge Valve T-Ring Air Supplies ML18348A9051980-05-12012 May 1980 Submittal of LER 1980-008-00 Update of Valve Leakage ML18347B1411978-09-0606 September 1978 LER 1978-029-00 for Palisades Plant Re Lower Level of Hydrazine in Iodine Removal Tank Due to Approximately 6% of Drainage from the Tank T-102 ML18347B1421978-08-18018 August 1978 LER 1978-028-00 for Palisades Plant Re Containment Building Purge Valve T-Ring in CV-1806 Was Not Pressurized ML18347B1441978-08-11011 August 1978 LER 1978-022-00 for Palisades Plant Re Four Incore Alarms Following Reactor Start-up ML18347B1451978-08-10010 August 1978 LER 1978-021-00 for Palisades Nuclear Plant, Containment Purge Supply Valve CV-1808 Failed to Open During Monthly Test ML18347B1491978-07-20020 July 1978 LER 1978-024-00 & LER 1978-025-00 for Palisades Nuclear Plant, Steam Generator Ph Dropped to 8.02 & One of Two Heaters for T-53B (Concentrated Boric Acid Tank) Failed ML18347B1781978-04-28028 April 1978 License Event Report LER-78-000-00 Re Out-of-Sequence Rod Withdrawal ML18347B1801978-04-19019 April 1978 License Event Report 78-008: Cycle 2 Core Axial Power Distribution Limits of TS 3.10.3 Were Exceeded by Approximately 12% for Steady State Operation During Cycle 2 ML18347B1811978-03-27027 March 1978 License Event Report 1978-007-00 Relates to Electrical Connectors Inside of Containment ML18347B1841978-03-13013 March 1978 Two Updated License Event Reports, LER-78-004 & LER-78-006 ML18348A1951978-03-0202 March 1978 License Event Report 1978-006-00 Re Shipping Cask Movement ML18347B1851978-03-0202 March 1978 License Event Report 1978-005-00 Re Steam Generator Level Instrumentation ML18348A1961978-03-0101 March 1978 License Event Report 1978-004-00 Re Steam Generator Pressure Instrumentation ML18348A1981978-02-0101 February 1978 License Event Report 1978-003-00 Re CV-3025 Failed Closed ML18348A1971978-02-0101 February 1978 License Event Report 1977-065-00 Re Operation in a Degraded Mode Permitted by a Limiting Condition for Operation ML18348A1991978-01-20020 January 1978 LER 1977-063-00 Re Iodine Removal System Hydrazene Tank, LER 1978-001-00 Re Containment Door Interlock Failure & LER 1978-002-00 Re Setpoints of Five Valves Were Outside Band ML18348A2001978-01-0606 January 1978 License Event Report 1977-062-00 Re Iodine Removal System Naoh Tank (T-103) ML18348A2011978-01-0606 January 1978 License Event Report 1977-064-00 Re HPSI Pump P-66B ML18348A2021977-12-21021 December 1977 LER 1977-054-00 Re Four Coincident In-Core Alarms, LER 1977-057-00 Re Pressure Set Point for Channel C, & LER 1977-058-00 Re De-Energized R Bus ML18348A2031977-12-16016 December 1977 License Event Report 1977-055-00 Re Loss of Off-Site Power and Plant Trip ML18348A2041977-12-12012 December 1977 License Event Report 1977-056-00 Re Gaseous Waste Discharge 2018-12-10
[Table view] |
Text
'
consumers
~---
1 eguiatory *
- Power company Mr James G Keppler Office of Inspection and Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - ER-77-15 AND ER-77 DISCHARGE ABOVE 5°F LIMIT
- Attached are two reportable occurrences which involve the discharge of cooling water above the 5°F limit for the Palisades Plant.
David P Hoffman Assistant Nuclear Licensing Administrator
.ICENSEE . EVENT REPORT
\,.)
CONTROL BLOCK:! I I I I I I (PLEASE PRINT ALL REQUIRED INFORMATION]
1 6 LICENSEE LICENSE EVENT
. NAME LICENSE NUMBER TYPE. TYPE IM I r I PI A I LI 1 I
- I oIo 1-1 o I o Lo I o I o 1-1 oI o I 14111111111 I ol 3 I
.. 8 9 14 15 . 25 26 30 31 32 REPORT REPORT TYPE. SOURCE OOCKl;T NUMBER EVENT DATE REPORT OATE 7
@illcoN'T 8
r* I *I L1J 57 58 59 LlJ 60 61 I 01510I-lo1215151 lol6l213l7l61 68 69 74 1012121317171 75 80 EVENT DESCRIPTION lol2I ~I_Wh_i_l_e_o_p_e_r_a_t_i_n-g_at__ful_l__.P...o_w_e_r__,,_an __e_v_e_n_t_w_h_i_c_h_r_e_s_ul_t_e_d_in_d_i_*s_c_h_a_r_g__e_w_a_t_e_r_a_b_o_v_e_t_h_e_......I 7 8 9 80 lol3ll._....-5__F_l_i_rru_*_t_o_c_c_ur_r_e_d_._*_T_h_e_d_i_*s_c_h_ar_,g.._e_a_v_e_r_a_..g._e_d_l_e_s_s_t_h_a_n_*.._5_°F_o_v_e_r_t_h_e_l_i_m_i_t_f_o_r_a_..p_-_ _......I 0
7 .8 9 80 lol411...--=p._r_o_x_i_m_a_t_e_l.::.y_2_h_o_ur...._s_._M_a_x_i_*m_:um_""".t...e_mp-=-e_r_a_t_ur_e_w_a_s_l__F...;.*_o_v_er_._.t_h_e_l_i_*m_i_*t_._T_h_i_s..__e_v_e_n_t_w_a_s_ _......I 0 7 8 9 80 lo Isl *~I_..i""'d""'e""'n""'t"'"i-=f_.i..,e..d._,.o...n.......2.._/...,9._/....7..._7_w.....h-.1...* 1-.e...._.r....e"""v....i...e....w...i...n=g._.p""'a""'s""'t...__r"""e""c""'o.-r..;:;;d=s....;..- - - - - - " - (E_R_-_7.;...7.;...-_l_.5-')'--------......
7 8 9 80 1
lol6I 7 8 9 PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT CODE CODE . COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION 7
@El IHI Fl 8 9 10 W
11 12 lzlzlzlzlzlzl 17 w 43 44 IzI z Iz IzI 47 w48 CAUSE DESCRIPTION
~ I..._E_v_e_n_t_i_s_*_d_u_e_t_o..._c_o_o_l_i_n__g_w_*a_t_e_r_s_,y....s_t_e_m_d_e_s_i.....g__n_.__NP_D_E_S_l_irru_*t_s_w_e_r_e_n_o_t_e_x_c_e_e_d_e_d_._ _ _ __.I 7 8 9 80 lol91 80
.7..* 89 0s"----------------------------------------------------'00 FACILITY METHOD OF
% POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION w
STATUS 7
EEJ8 9 10 I 0 I 9 I s121 13 NA 44 w 45 46 I Review of Records 80 FORM OF ACTIVITY CONTENT 7
rn w 8 RELEASED 9
OF RELEASE
~I 10 11 AMOUNT OF ACTIVITY NA 44 45 NA LOCATION OF RELEASE 80 PERSONNEL EXPOSURES 7
1fil1010101 8 9 NUMBER 11 wTYPE 12 13 DESCRIPTION NA 80 PERS'ONNEL INJURIES NUMBER DESCRIPTION IIEJl010101 NA 7 8 9 11 12 80 PROBABLE CONSEQUENCES .
.[lfil None.
7 8 9 80 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION
~w NA 80 7 8 9 10 PUBLICITY IT0 NA 89 80
- ADDITIONAL FACTORS l21fil NA 7 8 9 80
@fil 7 8 9 80 l *---
4
.ICENSEE EVENT REPORT**
'I ......
... Palisades CONTROL BLOCK: I I I I I I I [PLEASE PRINT AU REQUIRED INFORMATION]
1 6 LICENSEE LICENSE EVENT
~ NAME LICENSE NUMBER TYPE TYPE
~IMlrlPIAILl1I Io Io 1-1 o Io Io Io Io 1-1 o Io I l411l1l1l11 lol3I 7 8 9 14 15 25 26 30 31 32 REPORT REPORT TYPE. SOURCE OOCKl;T NUMBER EVENT OATE . REPORT DATE
@ElcoN'T l 7 8 57
- 1* 58*I l1J 59 w 60 I 0.1 5 I o 1-1 61 o 12 I5 I5 I 68 1012111011111 69 74 1012121317171 75 . 80 EVENT DESCRIPTION
@:@] I During power escalation on February 10, 1977, two events occurred which resulted in I 7 8 9 80
'-'.....;;d:;;:i;.::s;.,;;;c~h=a:;::.r.i;ig..:e_w=a~t.;;;.e:::.r-::::ab:,O::,V..:..~;;;__t;:;..:h:.:,;e:;.....5::...0...;;F~l::.:i:::IIU::::":.;:t:..:.~..;:T;.::h:;,;:e;.....::d;.:i.::.s.::.ch::a:::.r:::.gc;i.e:::,S:;:....;a:::.V..:..e:::.;r:,.:a:::ig;;i;e::.:d:::....:l::.;e::.:s::.:s::.,....;t::.:h.:.;;a:::ri:.....::l:;....;F__;:o:..:v..;:;e;,;:r.....;;t~h:.::e;......,JI 0
I0131 7 8 9 80 lol41 I Jjmjt. The total tjme over the ljmjt.f'or the eyents was 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, JO mjnutes, and I 7 8. 9 . 80 lo151 I the ma.Ximum temperature was 9°F over the limit. (ER-77-16) . I 7 8 9 80 lol6I 7 8 9. PRIME 80 SYSTEM CAUSE COMPONENT COMPONENT COOE CODE COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION 7
@El !Hf 8 9 10 Fl lLJ 11 12 lzlzlzlzlzlzl 17 L!J43 44 I z I z I z Iz I 47 w 48 CAUSE DESCRIPTION
@:@J. I . These events related to the starting or stopping of' a cooling tower pump (P-39A) I 7 8 9 80 lolsl I during power escalation. NPDES limits were not exceeded. I
~9 80
~ 9~-----------------------..,...-----------------------------------------------------------8.....10 FACILITY METHOD .OF STATUS % POWER OTHER STATUS DISCOVERY DISCOVERY' DESCRIPTION EEJ8 7 9 l.Ll 10 I oI 3 I s12I 13I Power Escalation.
44 I w 45 46 NA 80 FORM OF ACTIVITY CONTENT rn 7 8 RELEASED 9
~
OF RELEASE
AMOUNT OF ACTIVITY NA 44 45 NA LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION ITEi8 9Io I o I oj11
~--...;;NA=----------------------1 80 PERSONNEL INJURIES NUMBER DESCRIPTION EEi I 01 01 *o I ~---NA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _........,,___,__ _ _ _ _......J 7 8 9 . 11 12 80 PROBABLE CONSEQUENCES fiJfil None.
80 7 8 9 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION
!ill8 9Ll 7 10 NA 80 PUBLICITY
[ill] NA 89 . 80
~ NA 80 7 8 9 7
DE!8 9 80 L