INCLUDES CONFIDENTIAL INFORMATION - WITHHOLD UNDER 10 CFR 2.390 Unrestricted Upon Removal of Enclosure 4P Nuclear Development, LLC 3 Bethesda Metro Center Suite 515 Bethesda, MD 20814 November 13, 2018 10 CFR 50.80 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

Application for Order Approving Construction Permit Transfers and Conforming Administrative Construction Permit Amendments Bellefonte Nuclear Plant, Units 1 and 2 Construction Permits Nos. CPPR-122 and CPPR-123 NRC Docket Nos. 50-438 and 50-439 In accordance with Section 184 of the Atomic Energy Act, 10 CFR 50.80, and the Commission Policy Statement on Deferred Plants, 52 Federal Register 38077, Oct. 14, 1987 (Deferred Plants Policy),

Nuclear Development LLC (Nuclear Development) hereby submits the enclosed application (Application) requesting that the U.S. Nuclear Regulatory Commission (NRC) consent to the transfer of Construction Permit Nos. CPPR-122 and CPPR-123 (the Permits) for the Bellefonte Nuclear Plant, Units 1 and 2 (Bellefonte Units) now held by the Tennessee Valley Authority (TVA) to Nuclear Development. Nuclear Development also requests that the NRC issue the conforming administrative amendments described in the Application and amend the Permits to reflect the revised construction completion dates discussed therein. To the extent the NRC does not have sufficient time to decide substantively on the matters requested in the Application prior to closing of the asset transfer, Nuclear Development requests that the NRC hold the Permits in terminated plant (but unexpired and not withdrawn) status, consistent with the Section III.B of the Deferred Plants Policy, until such time as the Commission has reached its determination on these requests.

Nuclear Development is a special purpose entity owned by Mr. and Mrs. Franklin L. Haney and trusts for members of their family. In 1967, Mr. Haney founded the Franklin L. Haney Company, LLC, a highly-successful, privately-held real estate and property development company with headquarters in Chattanooga, TN and Washington, DC. The Franklin L. Haney Company has more than 40 years of experience in project development and a development portfolio of more than $10 billion. Its model for success has included engaging partners with project-related expertise, as with the Dulles Greenway Toll Road project. Additional information about Nuclear Development is contained in the Application.

U.S. Nuclear Regulatory Commission November 13, 2018 Page 2 As noted by TVA in its March 31, 2017 letter, Nuclear Development was the successful bidder in an auction for the plant conducted by TVA in November of 2016. Under the terms of the Purchase and Sale Agreement as amended, (enclosed with the Application as Attachment 1), Nuclear Development plans to purchase from TVA the Bellefonte Purchased Assets, including certain real property, material equipment, machinery, tools, other tangible property, books and records (including permitting, quality assurance, maintenance and other records related to design, construction or operation of the Units), certain agreements and obligations, and subject to all applicable law, all permits, and authorizations, including the Permits that are the subject of this Application. As amended, the current agreement with TVA would require closing of the asset transfer by November 30, 2018. However, the parties may agree to a further extension.

Nuclear Developments business objectives are to obtain the appropriate authority to safely complete high quality construction of Units 1 and 2, reactivate the docketed Operating License Application, begin commercial operation, and sell clean, safe, reliable power from the plants in the regional wholesale market. Toward those objectives, Nuclear Development has begun a methodical, stepwise approach to this project, including identifying leaders in the nuclear industry to augment its core team to better develop a regulatory roadmap, ensure appropriate oversight of quality and safety, plan construction methods and reliably estimate costs, solicit interest of potential power customers, and pursue available financial incentives that make private sector pursuit of a project of this magnitude achievable and economical. It has made substantial progress on all of these fronts and expects to proceed with the purchase as planned. Nuclear Development approaches this project with an appreciation for the safety significance of the approvals it is requesting and an appreciation for its responsibilities to provide the NRC the requisite bases for the supporting findings the agency must make before granting each requested approval in sequence.

Both Bellefonte Units are currently in Deferred Plant Status. In 2011, NRC extended the construction date for Unit 1 to October 1, 2020. In 2014, TVA requested an extension of the completion date for Unit 2. On March 31, 2017, TVA provided an update on that extension request noting the continuing timely renewal status of that application under 10 CFR § 2.109 and informing NRC of the planned sale of the Bellefonte Units to Nuclear Development. This update also deferred action regarding a revised construction completion date to interaction between NRC and Nuclear Development. Thus, Unit 2 remains in timely renewal status. The enclosed Application provides the basis for and requests updated construction completion dates for both units, i.e., October 1, 2029 for Unit 1, and October 1, 2030 for Unit 2.

Nuclear Development recognizes that Section 185 of the Atomic Energy Act and NRC regulations at 10 CFR 50.10(c) require that a company hold a Construction Permit before performing licensed construction, subject to any other regulatory restrictions. Nuclear Development plans to close on the acquisition of the Bellefonte Units (and related Purchased Assets), but undertake no licensed construction activities unless and until the NRC grants the authority requested in this Application. Nuclear Development is guided in this approach by the considerations explained in Section III.B.2 of the Deferred Plant Policy related to transfers of plants in deferred or terminated construction status, and whose Construction Permits have not been withdrawn by the NRC. Once the Permits have been transferred, Nuclear Development plans to continue only the status quo physical preservation, security and safety activities now being conducted by TVA. The Application describes Nuclear Developments plans for oversight of these site preservation, security and safety activities in the interim period and following Permit transfer and before restarting licensed construction, during which they will no longer be subject to

U.S. Nuclear Regulatory Commission November 13, 2018 Page 3 TVAs oversight. Specifically, and as noted above, to the extent the Permits are not transferred to Nuclear Development prior to closing, and the plant is placed in terminated plant status, Nuclear Development has no intent to, and will not, perform licensed or construction activities on the site prior to Permit transfer.

Nuclear Development will staff its Owners oversight organization and build its internal technical capabilities. It will contract with qualified providers for security and training, and it expects to offer employment to members of the existing Bellefonte site personnel upon completing the transaction. The Nuclear Development organization, leadership and quality assurance program description are discussed in the Application. Consistent with Section III.A.3 of the Deferred Plant Policy Statement, and upon transfer of the Permits, Nuclear Development will ensure effective quality assurance and implement oversight activities commensurate with regulatory and Permit requirements. Nuclear Development expects to receive the Permits in the same Deferred Plant status in which they currently exist, and as described in TVAs letter to the NRC in August 2009.

Nuclear Development has engaged an experienced, recognized and respected Engineering, Procurement and Construction Management (EPCM) contractor, SNC-Lavalin Nuclear (USA) (SLN) to lead the next engineering and construction phases of the Bellefonte project. SLN and its affiliates have substantial nuclear design and construction experience in North America and around the world and are well suited to this construction completion project. As such, Nuclear Development is technically qualified to maintain the Bellefonte Units in Deferred Plant status.

Prior to moving beyond Deferred Plant status and beginning licensed construction activities, Nuclear Development plans to enhance its Owners oversight organization by engaging experienced professionals and/or an experienced nuclear plant operating company with a track record for successfully managing important safety-related projects of comparable scale. Prior to reactivating construction, Nuclear Development will submit the information required by Section III.A.6 of the Deferred Plants Policy, including a description of the management and organization responsible for construction of the plant.

Nuclear Development plans to implement an approach by which it harnesses the technical expertise of multiple partners. For example, Nuclear Development anticipates engaging Framatome Inc.

(Framatome), the successor of the owner of the Babcock & Wilcox model 205 design, to assist with the nuclear steam supply system design in the design phase. During the design and construction phases of the project, Nuclear Development plans to bid scopes of work to select experienced and qualified candidates.

The successful bidders will perform their scopes under SLNs EPCM authority and Nuclear Developments oversight.

Nuclear Development has been established solely for the purpose of completing the construction of the Bellefonte Units. Under the Purchase and Sale Agreement, Nuclear Development has been reimbursing TVA for the ongoing costs of maintaining the Bellefonte Units in Deferred Plant status since November 2016. Until commercial financing of the project has been completed, Nuclear Development plans to continue to pay those costs with funds provided by its owners.

Nuclear Development is pursuing a project finance model for completion of construction of Bellefonte Units 1 and 2, similar to the approach applied in recent merchant plant combined license applications before the NRC. Nuclear Development has obtained production tax credits from the Internal Revenue Service for the output of the Bellefonte Units. It is negotiating with the Department of Energy Loan

U.S. Nuclear Regulatory Commission November 13, 2018 Page 4 Program Office for a loan guarantee under the Energy Policy Act of 2005 and expects to receive a conditional commitment. In that process Nuclear Development has developed high quality cost and schedule estimates for completion of construction. As explained in the Application, and consistent with NRC precedents, Nuclear Development is requesting an exemption pursuant to 10 CFR § 50.12 from certain regulatory requirements related to financial qualifications for construction permits and has proposed the use of alternative financial qualification standards.

The Application requests a financial qualification license condition required to be satisfied before licensed construction. This condition would require Nuclear Development to provide an updated cost estimate, documentation of differences from previous estimates, and documentation of closing on financing for the project. Nuclear Development has adopted the approach explained in SECY-15-0123.

The Application demonstrates satisfaction of the alternative standards by showing that Nuclear Development possesses or has reasonable assurance of obtaining the funds necessary to cover the estimated costs of possessing and maintaining the facility in a deferred status prior to resuming construction, and that it appears to be financially qualified to complete construction of the facility upon satisfying the condition.

Additional information pertaining to the proposed transfer of the Permits, including the information required under 10 CFR 50.80, is included in the Application. As that information demonstrates: (1) the proposed transfer of the Permits to Nuclear Development will allow Nuclear Development to complete the construction of the Bellefonte Units; (2) Nuclear Development has the requisite managerial, technical, and financial qualifications to be the holder of the Permits; (3) the material terms of the Permits will not be affected; and (4) the transfer of the Permits to Nuclear Development will not result in any impermissible foreign ownership, control or domination.

Pursuant to 10 CFR 50.90, Nuclear Development also requests NRC approval of certain administrative amendments to conform the Permits to reflect the proposed transfer. The changes are shown in Attachments 2 and 4 to this letter. Administrative changes to documents other than the Permits may be necessary upon Nuclear Developments assumption of control over the Bellefonte site. Changes to documents such as the QA and QV programs will be achieved as required by NRC regulations, such as 10 CFR 50.34, 10 CFR 50.55, and 10 CFR 50.55a.

In accordance with 10 CFR 50.91(b)(1), a copy of this submittal has been sent to the State of Alabama.

Nuclear Development respectfully request that the NRC review and complete action expeditiously on the enclosed Application. Nuclear Development requests NRC issue an order granting its consent and issuing the amended Permits as soon as practicable. Nuclear Development is prepared to work closely with the NRC Staff to facilitate the Applications review. Nuclear Development requests that NRC issue the Order approving the amendments to the Permits and authorizing the transfer.

In summary, the proposed transfer of the Permits will not be inimical to the common defense and security or result in any undue risk to public health and safety, and the transfer will be consistent with the requirements of the Atomic Energy Act and the NRC regulations.

Service upon the Nuclear Development of any notices, comments, hearing requests, intervention petitions, or other pleadings should be made to Timothy P. Matthews, Morgan, Lewis & Bockius LLP,

INCLUDES CONFIDENTIAL INFORMATION - WITHHOLD UNDER 10 CFR 2.390 Unrestricted Upon Removal of Enclosure 4P Nuclear Development, LLC 3 Bethesda Metro Center Suite 515 Bethesda, MD 20814 November 13, 2018 10 CFR 50.80 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

Application for Order Approving Construction Permit Transfers and Conforming Administrative Construction Permit Amendments Bellefonte Nuclear Plant, Units 1 and 2 Construction Permits Nos. CPPR-122 and CPPR-123 NRC Docket Nos. 50-438 and 50-439 In accordance with Section 184 of the Atomic Energy Act, 10 CFR 50.80, and the Commission Policy Statement on Deferred Plants, 52 Federal Register 38077, Oct. 14, 1987 (Deferred Plants Policy),

Nuclear Development LLC (Nuclear Development) hereby submits the enclosed application (Application) requesting that the U.S. Nuclear Regulatory Commission (NRC) consent to the transfer of Construction Permit Nos. CPPR-122 and CPPR-123 (the Permits) for the Bellefonte Nuclear Plant, Units 1 and 2 (Bellefonte Units) now held by the Tennessee Valley Authority (TVA) to Nuclear Development. Nuclear Development also requests that the NRC issue the conforming administrative amendments described in the Application and amend the Permits to reflect the revised construction completion dates discussed therein. To the extent the NRC does not have sufficient time to decide substantively on the matters requested in the Application prior to closing of the asset transfer, Nuclear Development requests that the NRC hold the Permits in terminated plant (but unexpired and not withdrawn) status, consistent with the Section III.B of the Deferred Plants Policy, until such time as the Commission has reached its determination on these requests.

Nuclear Development is a special purpose entity owned by Mr. and Mrs. Franklin L. Haney and trusts for members of their family. In 1967, Mr. Haney founded the Franklin L. Haney Company, LLC, a highly-successful, privately-held real estate and property development company with headquarters in Chattanooga, TN and Washington, DC. The Franklin L. Haney Company has more than 40 years of experience in project development and a development portfolio of more than $10 billion. Its model for success has included engaging partners with project-related expertise, as with the Dulles Greenway Toll Road project. Additional information about Nuclear Development is contained in the Application.

U.S. Nuclear Regulatory Commission November 13, 2018 Page 2 As noted by TVA in its March 31, 2017 letter, Nuclear Development was the successful bidder in an auction for the plant conducted by TVA in November of 2016. Under the terms of the Purchase and Sale Agreement as amended, (enclosed with the Application as Attachment 1), Nuclear Development plans to purchase from TVA the Bellefonte Purchased Assets, including certain real property, material equipment, machinery, tools, other tangible property, books and records (including permitting, quality assurance, maintenance and other records related to design, construction or operation of the Units), certain agreements and obligations, and subject to all applicable law, all permits, and authorizations, including the Permits that are the subject of this Application. As amended, the current agreement with TVA would require closing of the asset transfer by November 30, 2018. However, the parties may agree to a further extension.

Nuclear Developments business objectives are to obtain the appropriate authority to safely complete high quality construction of Units 1 and 2, reactivate the docketed Operating License Application, begin commercial operation, and sell clean, safe, reliable power from the plants in the regional wholesale market. Toward those objectives, Nuclear Development has begun a methodical, stepwise approach to this project, including identifying leaders in the nuclear industry to augment its core team to better develop a regulatory roadmap, ensure appropriate oversight of quality and safety, plan construction methods and reliably estimate costs, solicit interest of potential power customers, and pursue available financial incentives that make private sector pursuit of a project of this magnitude achievable and economical. It has made substantial progress on all of these fronts and expects to proceed with the purchase as planned. Nuclear Development approaches this project with an appreciation for the safety significance of the approvals it is requesting and an appreciation for its responsibilities to provide the NRC the requisite bases for the supporting findings the agency must make before granting each requested approval in sequence.

Both Bellefonte Units are currently in Deferred Plant Status. In 2011, NRC extended the construction date for Unit 1 to October 1, 2020. In 2014, TVA requested an extension of the completion date for Unit 2. On March 31, 2017, TVA provided an update on that extension request noting the continuing timely renewal status of that application under 10 CFR § 2.109 and informing NRC of the planned sale of the Bellefonte Units to Nuclear Development. This update also deferred action regarding a revised construction completion date to interaction between NRC and Nuclear Development. Thus, Unit 2 remains in timely renewal status. The enclosed Application provides the basis for and requests updated construction completion dates for both units, i.e., October 1, 2029 for Unit 1, and October 1, 2030 for Unit 2.

Nuclear Development recognizes that Section 185 of the Atomic Energy Act and NRC regulations at 10 CFR 50.10(c) require that a company hold a Construction Permit before performing licensed construction, subject to any other regulatory restrictions. Nuclear Development plans to close on the acquisition of the Bellefonte Units (and related Purchased Assets), but undertake no licensed construction activities unless and until the NRC grants the authority requested in this Application. Nuclear Development is guided in this approach by the considerations explained in Section III.B.2 of the Deferred Plant Policy related to transfers of plants in deferred or terminated construction status, and whose Construction Permits have not been withdrawn by the NRC. Once the Permits have been transferred, Nuclear Development plans to continue only the status quo physical preservation, security and safety activities now being conducted by TVA. The Application describes Nuclear Developments plans for oversight of these site preservation, security and safety activities in the interim period and following Permit transfer and before restarting licensed construction, during which they will no longer be subject to

U.S. Nuclear Regulatory Commission November 13, 2018 Page 3 TVAs oversight. Specifically, and as noted above, to the extent the Permits are not transferred to Nuclear Development prior to closing, and the plant is placed in terminated plant status, Nuclear Development has no intent to, and will not, perform licensed or construction activities on the site prior to Permit transfer.

Nuclear Development will staff its Owners oversight organization and build its internal technical capabilities. It will contract with qualified providers for security and training, and it expects to offer employment to members of the existing Bellefonte site personnel upon completing the transaction. The Nuclear Development organization, leadership and quality assurance program description are discussed in the Application. Consistent with Section III.A.3 of the Deferred Plant Policy Statement, and upon transfer of the Permits, Nuclear Development will ensure effective quality assurance and implement oversight activities commensurate with regulatory and Permit requirements. Nuclear Development expects to receive the Permits in the same Deferred Plant status in which they currently exist, and as described in TVAs letter to the NRC in August 2009.

Nuclear Development has engaged an experienced, recognized and respected Engineering, Procurement and Construction Management (EPCM) contractor, SNC-Lavalin Nuclear (USA) (SLN) to lead the next engineering and construction phases of the Bellefonte project. SLN and its affiliates have substantial nuclear design and construction experience in North America and around the world and are well suited to this construction completion project. As such, Nuclear Development is technically qualified to maintain the Bellefonte Units in Deferred Plant status.

Prior to moving beyond Deferred Plant status and beginning licensed construction activities, Nuclear Development plans to enhance its Owners oversight organization by engaging experienced professionals and/or an experienced nuclear plant operating company with a track record for successfully managing important safety-related projects of comparable scale. Prior to reactivating construction, Nuclear Development will submit the information required by Section III.A.6 of the Deferred Plants Policy, including a description of the management and organization responsible for construction of the plant.

Nuclear Development plans to implement an approach by which it harnesses the technical expertise of multiple partners. For example, Nuclear Development anticipates engaging Framatome Inc.

(Framatome), the successor of the owner of the Babcock & Wilcox model 205 design, to assist with the nuclear steam supply system design in the design phase. During the design and construction phases of the project, Nuclear Development plans to bid scopes of work to select experienced and qualified candidates.

The successful bidders will perform their scopes under SLNs EPCM authority and Nuclear Developments oversight.

Nuclear Development has been established solely for the purpose of completing the construction of the Bellefonte Units. Under the Purchase and Sale Agreement, Nuclear Development has been reimbursing TVA for the ongoing costs of maintaining the Bellefonte Units in Deferred Plant status since November 2016. Until commercial financing of the project has been completed, Nuclear Development plans to continue to pay those costs with funds provided by its owners.

Nuclear Development is pursuing a project finance model for completion of construction of Bellefonte Units 1 and 2, similar to the approach applied in recent merchant plant combined license applications before the NRC. Nuclear Development has obtained production tax credits from the Internal Revenue Service for the output of the Bellefonte Units. It is negotiating with the Department of Energy Loan

U.S. Nuclear Regulatory Commission November 13, 2018 Page 4 Program Office for a loan guarantee under the Energy Policy Act of 2005 and expects to receive a conditional commitment. In that process Nuclear Development has developed high quality cost and schedule estimates for completion of construction. As explained in the Application, and consistent with NRC precedents, Nuclear Development is requesting an exemption pursuant to 10 CFR § 50.12 from certain regulatory requirements related to financial qualifications for construction permits and has proposed the use of alternative financial qualification standards.

The Application requests a financial qualification license condition required to be satisfied before licensed construction. This condition would require Nuclear Development to provide an updated cost estimate, documentation of differences from previous estimates, and documentation of closing on financing for the project. Nuclear Development has adopted the approach explained in SECY-15-0123.

The Application demonstrates satisfaction of the alternative standards by showing that Nuclear Development possesses or has reasonable assurance of obtaining the funds necessary to cover the estimated costs of possessing and maintaining the facility in a deferred status prior to resuming construction, and that it appears to be financially qualified to complete construction of the facility upon satisfying the condition.

Additional information pertaining to the proposed transfer of the Permits, including the information required under 10 CFR 50.80, is included in the Application. As that information demonstrates: (1) the proposed transfer of the Permits to Nuclear Development will allow Nuclear Development to complete the construction of the Bellefonte Units; (2) Nuclear Development has the requisite managerial, technical, and financial qualifications to be the holder of the Permits; (3) the material terms of the Permits will not be affected; and (4) the transfer of the Permits to Nuclear Development will not result in any impermissible foreign ownership, control or domination.

Pursuant to 10 CFR 50.90, Nuclear Development also requests NRC approval of certain administrative amendments to conform the Permits to reflect the proposed transfer. The changes are shown in Attachments 2 and 4 to this letter. Administrative changes to documents other than the Permits may be necessary upon Nuclear Developments assumption of control over the Bellefonte site. Changes to documents such as the QA and QV programs will be achieved as required by NRC regulations, such as 10 CFR 50.34, 10 CFR 50.55, and 10 CFR 50.55a.

In accordance with 10 CFR 50.91(b)(1), a copy of this submittal has been sent to the State of Alabama.

Nuclear Development respectfully request that the NRC review and complete action expeditiously on the enclosed Application. Nuclear Development requests NRC issue an order granting its consent and issuing the amended Permits as soon as practicable. Nuclear Development is prepared to work closely with the NRC Staff to facilitate the Applications review. Nuclear Development requests that NRC issue the Order approving the amendments to the Permits and authorizing the transfer.

In summary, the proposed transfer of the Permits will not be inimical to the common defense and security or result in any undue risk to public health and safety, and the transfer will be consistent with the requirements of the Atomic Energy Act and the NRC regulations.

Service upon the Nuclear Development of any notices, comments, hearing requests, intervention petitions, or other pleadings should be made to Timothy P. Matthews, Morgan, Lewis & Bockius LLP,

U.S. Nuclear Regulatory Commission November 13,2018 Page 5 1111 Pennsylvania Ave., NW, Washington, D.C. 20004 (Tel: 202.739.5527; email:

timothy.matthews(almorganlewis.com).

In the event that the NRC has any questions about the proposed transaction described in this letter and in the Application or wishes to obtain any additional information about the transfer of the Permits, please contact me at work: 828.686.1621, mobile: 828.333.2609, or email: bill@wrmccollum.com.

Sincerely,

~~~~

Chief Executive Officer & Chief Nuclear Officer Nuclear Development LLC

Enclosures:

Attachment 1-Application for Order Approving Construction Permit Transfers and Conforming Administrative Construction Permit Amendments (Construction Permit Nos. CPPR-122 and CPPR-123) - Bellefonte Unit I Construction Permit (Changes) - Bellefonte Unit 1 Construction Permit (Clean Pages) - Bellefonte Unit 2 Construction Permit (Changes) - Bellefonte Unit 2 Construction Permit (Clean Pages) cc w/

Enclosures:

William Gleaves, Project Manager U.S. Nuclear Regulatory Commission Regional Administrator, Region II U.S. Nuclear Regulatory Commission State Health Officer Alabama Dept. of Public Health P.O. Box 303017 Montgomery, AL 36130-3017 Mr. Mike Balduzzi Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 1101 Market Street Lookout Place 3R Chattanooga, TN 37402-2801

CITY OF WASHINGTON DISTRICT OF COLUMBIA

)

) SS.

)

AFFIRMATION William R. McCollum, Jr., being duly sworn according to law deposes and says:

I am Chief Nuclear Officer, Nuclear Development LLC and, as such, I am familiar with the contents of this correspondence and the attachments thereto concerning the Bellefonte Nuclear Plant, and the matters set forth therein regarding Nuclear Development LLC are true and correct to the best of my knowledge, information and belief.

Subscribed and Sworn to before me

~~-----

ATTACHMENT 1 APPLICATION FOR ORDER APPROVING CONSTRUCTION PERMIT TRANSFERS AND CONFORMING ADMINISTRATIVE CONSTRUCTION PERMIT AMENDMENTS BELLEFONTE NUCLEAR PLANT, UNITS 1 AND 2 NRC CONSTRUCTION PERMITS NOS. CPPR-122 AND CPPR-123 NRC DOCKET NOS. 50-438 AND 50-439 ATTACHMENT 1

- Application for Order Approving Construction Permit Transfers and Conforming Administrative Construction Permit Amendments (Construction Permit Nos. CPPR-122 and CPPR-123)

Table of Contents Page 1.

Introduction 1

2.

Statement of Purpose of Transfer and Nature of the Transaction Making the Transfer Necessary or Desirable 2

3.

General Corporate Information Regarding Nuclear Development LLC 3

4.

Technical Qualifications 4

5.

Financial Qualifications 7

6.

Restricted Data 11 7.

Other Nuclear Regulatory Issues 11

8.

Requested Review Schedule and Other Required Approvals 13

9.

Regulatory Safety Analysis 13 10.

Environmental Considerations 14

11.

Summary 14 Bellefonte Nuclear Plant Site Purchase and Sales Agreement Resumes of Key Management Personnel Request for Exemption Regarding Financial Qualification Applicable to Application to Transfer Construction Permits CPPR-122 and CPPR-123 Projected Total Project Costs for Bellefonte Units 1 & 2 (Non-proprietary) P Projected Total Project Costs for Bellefonte Units 1 & 2 (Proprietary)

Quality Assurance Plan

Page 1 of 14

1. Introduction In accordance with Section 184 of the Atomic Energy Act, 10 CFR 50.80, and the Commission Policy Statement on Deferred Plants, 52 Federal Register 38077, Oct. 14, 1987 (Deferred Plants Policy), Nuclear Development LLC (Nuclear Development) hereby submits this application (Application) requesting that the U.S. Nuclear Regulatory Commission (NRC) consent to the transfer of Construction Permit Nos. CPPR-122 and CPPR-123 (the Permits) for the Bellefonte Nuclear Plant, Units 1 and 2 (Bellefonte Units) now held by the Tennessee Valley Authority (TVA) to Nuclear Development. Nuclear Development also requests that the NRC issue conforming administrative amendments to reflect the transfer and amend the Permits to reflect revised construction completion dates discussed herein. To the extent the NRC does not have sufficient time to decide substantively on the matters requested in the Application prior to closing of the asset transfer, Nuclear Development requests that the NRC hold the Permits in terminated plant (but unexpired and not withdrawn) status, consistent with the Section III.B of the Deferred Plants Policy, until such time as the Commission has reached its determination on these requests.

Nuclear Development is a special purpose entity owned by Mr. and Mrs. Franklin L. Haney and trusts for members of their family. In 1967, Mr. Haney founded the Franklin L. Haney Company, LLC, a highly-successful, privately-held real estate and property development business with headquarters in Chattanooga, TN and Washington, DC. The Franklin L. Haney Company has more than 30 years of experience in project development and a development portfolio of more than $10 billion. Its model for success has included engaging partners with project-related expertise, as with the Dulles Greenway Toll Road project. Additional information about Nuclear Development is provided herein.

The site of the Bellefonte Units is located in Hollywood, Alabama. The site is comprised of two partially complete pressurized water reactors, each with a Babcock & Wilcox (B&W) model 205 nuclear steam supply system. TVA obtained the construction permits for the Bellefonte Units in December 1974 and began construction on both units in 1975. TVA continued construction through 1988 before electing to cease construction, with Unit 1 approximately 90%

complete and Unit 2 approximately 60% complete. From 1988 to 2016, TVA considered re-starting and completing one or both of the Bellefonte Units from time to time. During the time when construction was not proceeding, TVA performed some alterations to the Bellefonte Units to support layup and preservation of systems and components. In addition, in the mid-2000s, TVA removed a number of components for use elsewhere in the TVA system or for salvage. At the current time, Unit 1 is estimated to be approximately 55% physically complete and Unit 2 is estimated to be approximately 35% physically complete.

As noted by TVA in its March 31, 2017 letter, Nuclear Development was the successful bidder in an auction for the plant conducted by TVA in November of 2016. Under the terms of the Purchase and Sale Agreement, as amended (enclosed with the Application as Enclosure 1),

Nuclear Development plans to purchase from TVA the Bellefonte Purchased Assets, including certain real property, material equipment, machinery, tools, other tangible property, books and records (including permitting, quality assurance, maintenance and other records related to design, construction or operation of the Units), certain agreements and obligations, and subject to all applicable law, all permits, and authorizations, including the Permits that are the subject of this

Page 2 of 14 Application. As amended, the current agreement with TVA would require closing of the asset transfer by November 30, 2018. However, the parties may agree to a further extension.

Additional information pertaining to the proposed transfer of the Permits, including the information required under 10 CFR 50.80, is included in this Application. As that information demonstrates: (1) the proposed transfer of the Permits to Nuclear Development will allow Nuclear Development to complete the construction of the Bellefonte Units; (2) Nuclear Development has the requisite managerial, technical, and financial qualifications to be the holder of the Permits; (3) the material terms of the Permits will not be affected; and (4) the transfer of the Permits to Nuclear Development will not result in any impermissible foreign ownership, control or domination.

Pursuant to 10 CFR 50.90, Nuclear Development also requests NRC issue administrative amendments to conform the Permits to reflect the proposed transfer. The changes are shown in Attachments 2 and 4 to the letter transmitting this Application. Administrative changes to documents other than the Permits may be necessary upon Nuclear Developments assumption of control over the Bellefonte site. Changes to documents such as the quality assurance (QA) and quality verification (QV) programs will be achieved as required by NRC regulations, such as 10 CFR 50.34, 10 CFR 50.55, and 10 CFR 50.55a.

2. Statement of Purpose of Transfer and Nature of the Transaction Making the Transfer Necessary or Desirable The purpose of the transfer of the Permits from TVA to Nuclear Development is to complete construction of the Bellefonte Units. Nuclear Development will assume possession of and managerial responsibility for all licensed activities, including the QA and QV programs in deferred status, as well as the ultimate completion of construction of the Bellefonte Units.

Nuclear Development will be licensed to possess, maintain and construct the Bellefonte Units and to ultimately complete them.

The transfer of the Permits is desirable because Nuclear Development intends to complete the long-delayed construction of the Bellefonte Units. Nuclear Development will be able to complete the Bellefonte Units using the project financing model used for other major infrastructure projects.

Nuclear Developments business objectives are to obtain the appropriate authority to safely complete high quality construction of Units 1 and 2, update and reactivate the docketed Operating License Application, begin commercial operation, and sell clean, safe, reliable power from the plants in the regional wholesale market. Toward those objectives, Nuclear Development has begun a methodical, stepwise approach to this project, including: identify leaders in the nuclear industry to augment its core team to better develop a regulatory roadmap, ensure appropriate oversight of quality and safety, plan construction methods and reliably estimate costs, solicit interest of potential power customers, and pursue available financial incentives that make private sector pursuit of a project of this magnitude achievable and economical. It has made substantial progress on all of these fronts and expects to proceed with the purchase as planned. Nuclear Development approaches this project with an appreciation for

Page 3 of 14 the safety significance of the approvals it is requesting and an appreciation for its responsibilities to provide the NRC the requisite bases for the supporting findings the agency must make before granting each requested approval in sequence.

Both Bellefonte Units are currently in Deferred Plant Status. In 2011, NRC extended the construction date for Unit 1 to October 1, 2020. In 2014, TVA requested an extension of the completion date for Unit 2. On March 31, 2017, TVA provided an update on that extension request noting the continuing timely renewal status of that application under 10 CFR § 2.109 and informing NRC of the planned sale of the Bellefonte Units to Nuclear Development. This update also deferred action regarding a revised construction completion date to interaction between NRC and Nuclear Development. Thus, Unit 2 remains in timely renewal status; this Application provides the basis for and requests updated construction completion dates for both units, i.e.,

October 1, 2029 for Unit 1, and October 1, 2030 for Unit 2.

Nuclear Development recognizes that Section 185 of the Atomic Energy Act and NRC regulations at 10 CFR 50.10(c) require that a company hold a Construction Permit before performing licensed construction, subject to any other regulatory restrictions. Nuclear Development plans to close on acquisition of the Bellefonte Units (and related Purchased Assets), but undertake no licensed construction activities unless and until the NRC grants the authority requested in this Application. Nuclear Development is guided in this approach by the considerations explained in Section III.B.2 of the Deferred Plant Policy related to transfers of plants in deferred or terminated construction status, and whose Construction Permits have not been withdrawn by the NRC. Once the Permits have been transferred, Nuclear Development plans to continue only the status quo physical preservation, security and safety activities now being conducted by TVA. The Application describes Nuclear Developments plans for oversight of these site preservation, security and safety activities in the interim period and following Permit transfer and before restarting licensed construction, during which they will no longer be subject to TVAs oversight. Specifically, and as noted above, to the extent the Permits are not transferred to Nuclear Development prior to closing, Nuclear Development has no intent to, and will not, perform licensed or construction activities on the site prior to Permit transfer.

3. General Corporate Information Regarding Nuclear Development LLC a.

General Corporate Information and Description of Business Nuclear Development is a special purpose entity owned by Mr. and Mrs. Franklin L. Haney and trusts for members of their family, as follows:

Page 4 of 14 Franklin L. Haney, Sr.

15%

Emeline W. Haney 10%

Emeline W. Haney as trustee for Irrevocable Trusts for the Benefit of :

75%

Mary Alice Haney 15%

Mae Haney Grennan 15%

Margaret Haney 15%

E. Michelle Haney Maddux 15%

Franklin L. Haney, Jr.

15%

Nuclear Development is controlled by Franklin L. Haney, Sr. It is a manager managed LLC, and Mr. Haney is the sole manager. Mr. William R. McCollum, Jr. is its Chief Executive Officer (CEO) and Chief Nuclear Officer (CNO), and Frank L. Haney, Jr. is its President. Mr. Larry D.

Blust is its General Counsel and Secretary. Resumes for these key management personnel are provided in Enclosure 2.

b. No Foreign Ownership, Control, or Domination The owners and key management personnel of Nuclear Development are all U.S. citizens.

Consistent with the requirements of 10 CFR 50.38, Nuclear Development is not owned, controlled or dominated by an alien, a foreign corporation, or a foreign government.

c.

No Agency Nuclear Development is not acting as the agent or representative of another person in the proposed transfer of the Permits. As the licensed entity with possession and responsibility for management and construction of the Bellefonte site, Nuclear Development will act for itself.

4. Technical Qualifications As described below, Nuclear Development is technically qualified to carry out its responsibilities as the holder of the Permits in Deferred Plant status. Nuclear Development will complete the required design, engineering, and construction activities to complete the construction of the Bellefonte Units by leveraging the project finance model for completing the plants. This model will both allow it to maintain the plants in their current deferred status and then to transition to construction activities once engineering planning is completed.

a.

Owner Oversight Organization and Contractors Nuclear Development will staff its Owners oversight organization and build its internal technical capabilities. Nuclear Development has retained Mr. McCollum as its CEO and CNO.

Mr. McCollums resume is provided in Enclosure 2.

Nuclear Development also expects to offer employment to members of the existing Bellefonte site personnel upon completing the transaction. Consistent with Section III.A.3 of the Deferred

Page 5 of 14 Plant Policy Statement, and upon transfer of the Permits, Nuclear Development will ensure effective quality assurance and implement oversight activities commensurate with applicable regulatory and Permit requirements.

Nuclear Development has engaged an experienced, recognized and respected Engineering, Procurement and Construction Management (EPCM) contractor, SNC-Lavalin Nuclear (USA)

(SLN) to lead the next engineering and construction phases of the Bellefonte project. SLN and its affiliates have substantial nuclear design and construction experience in North America and around the world and are well suited to this construction completion project. As such, Nuclear Development is technically qualified to maintain the Bellefonte Units in Deferred Plant status.

SNL will be responsible for day to day QA activities under a 10 CFR Part 50, Appendix B QA Program.

Nuclear Development has retained a qualified QA Manager to conduct oversight of the SNL QA Plan upon transfer of the Bellefonte Units. His responsibility includes review and audit functions. Nuclear Development expects to receive the Permits in the same Deferred Plant status in which they currently exist, and as described in TVAs letter to the NRC dated May 12, 2009.1 Prior to moving beyond Deferred Plant status and beginning licensed construction activities, Nuclear Development plans to enhance its Owners oversight organization by engaging experienced professionals and/or an experienced nuclear plant operating company with a track record for successfully managing important safety-related projects of comparable scale. Prior to reactivating construction, Nuclear Development will submit the information required by Section III.A.6 of the Deferred Plants Policy, including a description of the management and organization responsible for construction of the plant as required by Section III.A.6.e. If necessary and/or desirable, the NRC staff could impose a license condition requiring that resumes for the individuals intended to staff the construction organization be submitted with the notice to NRC contemplated by Section III.A.6.

The organization for the completion of the Bellefonte Units will provide:

(1) A single Project Director and Site Executive Director (Project Director). In this role, the Project Director will be accountable for overall management, leadership, performance, nuclear safety, QA, QV, and employee safety.

(2) A contracted technical support adviser. Nuclear Development has contracted with MPR Associates (MPR), a leading specialty engineering and technical services firm in the U.S. power industry. MPR will serve as the owner lead for oversight, support, and review of key strategic activities, including, for example, instrumentation and control (I&C) implementation, seismic studies and implementation, and electrical distribution work. MPR will also support Nuclear Development on nuclear regulatory issues. MPR will report directly to the Project Director.

1 Letter from M. Bajestani to U.S. Nuclear Regulatory Commission, TVA Implementation of Order Granting Reinstatement of Construction Permits Nos. CPPR-122 and CPPR-123 (May 12, 2009) (ADAMS Accession No. ML091340285).

Page 6 of 14 (3) A project controls organization staff. Nuclear Development has engaged High Bridge, a leading project controls and project management services firm in the U.S. nuclear industry, to serve in this capacity. High Bridge will also be supported by MPR. This organization will report directly to the Project Director.

(4) A Site Director. This director will have day-to-day responsibilities to maintain the Bellefonte Units in their deferred status while engineering and other management activities continue.

(5) These owner representatives will support Nuclear Development and the Project Director in supervising various Senior Managers. Nuclear Development currently anticipates that these senior managers will include a Manager, Site Operations, a Construction Manager, and an Engineering Manager. Because the Permits will be transferred in a deferred status, with Nuclear Development not recommencing construction activities without prior notice to the NRC, these Senior Managers have not yet been engaged.

(6) Several Managers, directly reporting to the appropriate Senior Managers, with responsibilities for, industrial safety, project administration and financial services, training, labor relations, regulatory affairs, quality assurance, quality verification, licensing, environmental, project controls and, when appropriate, for radiological safety. These Managers may be contractors of their respective partners of Nuclear Development. This organization will provide a nuclear management team with control over the design, licensing and construction programs.

(7) Implementation of high industry standards, best practices, effective programs and processes, and management controls.

(8) Effective and integrated oversight and technical support functions.

The Bellefonte construction organization will provide an experienced nuclear management team to assure compliance with the requirements of the Permits and the Commissions regulations.

Nuclear Development will implement a management approach to assure efficient and effective engineering; construction planning, preparation, and execution; an effective corrective action program; performance reporting, monitoring, and metrics; procurement oversight; configuration management; effective quality assurance and quality verification program implementation; appropriate project controls; a safety conscious work environment; security; day-to-day industrial safety and management rigor; personnel performance; financial controls; and, when appropriate, preparations for operation including radiological safety.

Nuclear Development plans to implement an approach by which it harnesses the technical expertise of multiple partners. For example, Nuclear Development anticipates engaging Framatome, Inc. (Framatome), the successor of the owner of the B&W 205 design, to assist with the nuclear steam supply system design in the design phase. During the design and construction phases of the project, Nuclear Development plans to bid scopes of work to select experienced and qualified candidates. The successful bidders will perform their scopes under SLNs EPCM authority and Nuclear Developments oversight.

Page 7 of 14 Nuclear Development intends to subcontract technical support work only to qualified contractors who have the experience and past performance to ensure the timely and safe completion.

Contractors will be expected to have an excellent safety record and approved 10 CFR Appendix B quality assurance plans to support their scopes of work. Contractor support workers for the project will report to the appropriate Senior Manager. Regulatory compliance, safety performance and schedule performance will be emphasized in all contracts. The Nuclear Development integrated approach and the implementation of common programs, processes and best practices will ensure that the support functions for the Bellefonte Units construction are carried out efficiently.

b. Executive Oversight Board Further, Nuclear Development will establish an Executive Oversight Board. The Executive Oversight Board will be comprised of senior representatives from each important stakeholder to the project. This Executive Oversight Board will meet monthly to review the progress of the Project. Based on these meetings and the scope of responsibility for each of the key stakeholders, Nuclear Development expects that key recommendations will be provided and implemented to resolve issues that develop during the Project. Furthermore, this Oversight Board will review the results of these actions and take additional measures and actions as necessary. The meetings of the Executive Oversight Board will provide formal, independent oversight of project performance and safety.

c.

Conclusion The Nuclear Development management team is experienced and qualified, and the organization is well-designed to accomplish the final design, planning, and ultimate construction of the site.

The necessary management processes and controls will be applied, with clear lines of authority and communication. In addition, Nuclear Development will rely upon the experience and expertise of its strategic partners to perform key, specific portions of work scope to ensure safe and efficient construction of the Bellefonte Units. Accordingly, the proposed transfers have the potential to achieve synergies and management efficiencies at the Bellefonte Nuclear Plant, as well as expedite the completion of the Bellefonte Units. For these reasons, Nuclear Development and its management team have the necessary technical qualifications to safely complete construction of the Bellefonte Units.

5. Financial Qualifications Nuclear Development has been established solely for the purpose of constructing the Bellefonte Units. Under the Purchase and Sale Agreement, Nuclear Development has been reimbursing TVA for the ongoing costs of maintaining the Bellefonte Units in Deferred Plant status since November 2016. Until commercial financing of the project has been completed, Nuclear Development plans to continue to pay those costs using funds provided by its owners.

Nuclear Development is pursuing a project finance model for completion of construction of Bellefonte Units 1 and 2, similar to the approach applied in other recent merchant plant combined license applications issued by the NRC. Nuclear Development has obtained

Page 8 of 14 production tax credits from the Internal Revenue Service for the output of the Bellefonte Units.

It is negotiating with the Department of Energy (DOE) Loan Program Office for a loan guarantee under the Energy Policy Act of 2005 and expects to receive a conditional commitment.

In that process Nuclear Development has developed high quality cost and schedule estimates for completion of construction. Consistent with NRC precedents, Nuclear Development is requesting an exemption pursuant to 10 CFR § 50.12 from certain regulatory requirements related to financial qualifications for construction permits and has proposed the use of alternative financial qualification standards. Enclosure 3 provides Nuclear Developments Request for Exemption Regarding Financial Qualifications Applicable to Application to Transfer Construction Permits CPPR-122 and CPPR-123.

This Application requests a financial qualification license condition that is required to be satisfied before commencing licensed construction. The license condition would require that Nuclear Development provide an updated cost estimate, documentation of differences from previous estimates, and documentation of closing on the financing for the project. Nuclear Development has adopted the approach explained in SECY-15-0123. This Application demonstrates satisfaction of the alternative standards by showing that Nuclear Development possesses or has reasonable assurance of obtaining the funds necessary to cover the estimated costs of possessing and maintaining the facility in a deferred status prior to resuming construction, and that it appears to be financially qualified to complete construction of the facility upon satisfying the license condition.

a.

Maintaining and Possessing the Partially-Constructed Facility Nuclear Development possesses or has reasonable assurance of obtaining the funds necessary to cover estimated costs of possessing and maintaining the Bellefonte Units prior to resuming construction. The owners of Nuclear Development have funded the maintenance of the Bellefonte Units since November 2016, and they will continue to do so until construction financing is put in place to satisfy the license condition for commencing construction. As already noted, Mr. Haney has built a development business worth $10 billion. Moreover, the owners have demonstrated their ability to pay these costs given that they have already been doing so for the last two years.

b. Resuming and Completing Construction As demonstrated below, Nuclear Development is financially qualified to resume and complete construction of the Bellefonte Units. The information below reflects the financial capacity of Nuclear Development to obtain the necessary funding for the project and demonstrates its level of understanding of the size and scope of the project, including the level of capital necessary to undertake the project, and reflects the organizational and human resources, experience, skills, and expertise required to obtain proper financing and ultimately finance the project, when appropriate.

Page 9 of 14 (1) Construction Cost Estimate P provides the Projected Total Project Costs for Bellefonte Units 1 & 2. The estimate includes amounts for contingency, escalation, owners costs, capitalized interest during construction, and other financing costs. Note: Enclosure 4P is the proprietary version of this information; it is proprietary and confidential, and should be withheld from public disclosure. An affidavit in support of its proprietary nature is provided in Enclosure 4. A redacted, non-proprietary version of this enclosure that is suitable for release to the public is provided as Enclosure 4.

(2) Proposed Construction Permit Condition Nuclear Development proposes amending the Permits to include the following condition:

The licensee will notify the NRC at least 120 days prior to its anticipated date of resuming construction that this license condition has been fulfilled and that the following are available for inspection:

An updated cost estimate for completion of construction;

Documentation justifying any material variances from the original cost estimate provided in the application; and

Documentation demonstrating that the licensee has secured financing to fund the updated cost estimate for the completion of construction. This documentation will include operative closing documents, and may include documented proof of parent and affiliate assurances, or capital from other sources (as required to close the financing) that reflect financing for the project.

As used in this proposed license condition, the term construction has the same definition as contained in 10 CFR 50.10(a).

(3) Financial Capacity Plan This plan demonstrates Nuclear Developments level of understanding of the size and scope of construction of the Bellefonte Units, including the level of capital necessary to undertake the project. The plan also discusses the organizational and human resources, experience, skills, and expertise required to obtain proper financing and ultimately finance the project. The plan includes a description of the management team as it pertains to financing, and the teams experience and expertise in the areas of finance, capital sourcing, and large build projects.

i.

Description of Management Team for Financing This section discusses Nuclear Developments management team for financing of construction of the Bellefonte Units. The management team includes experienced financing professionals from Nuclear Development, as well as representatives and financial advisors from consultants. This section describes their experience with potential sources of project funding, including financing of the construction and operation of large energy and other infrastructure projects.

Page 10 of 14 A. Nuclear Developments Internal Financing Team Nuclear Developments internal management team includes experienced financing professionals.

Franklin Haney, Sr. is an experienced developer of large infrastructure projects, and Frank Haney, Jr. is an experienced financial executive and developer. Mr. Larry D. Blust also has extensive experience with project finance. In 1967, Mr. Haney founded the Franklin L. Haney Company, LLC, a highly-successful, privately-held real estate and property development company with headquarters in Chattanooga, TN and Washington, DC. The Franklin L. Haney Company has more than 40 years of experience in project development and a development portfolio of more than $10 billion. Its model for success has included engaging partners with project-related expertise, as with the Dulles Greenway Toll Road project. This major project involved the private development of fourteen miles of toll highway connecting Leesburg with Dulles Airport. Both Mr. Franklin Haney and Mr. Frank Haney were involved in arranging for

$2 billion in senior and mezzanine debt in connection with an expansion of the project to add a new lane in each direction.

Another large project is the Portals Office Building I and II, which includes 1.8 million square feet of prime office space, 125,000 of highly desirable retail and restaurant space and the 400-room Mandarin Oriental Hotel. The headquarters of the Federal Communications Commission is located in the Portals project. Other projects include the Birmingham Social Security Center (660,000 square feet), Dawson Creek, Colorado (1,900 acre residential development), and 101 Marietta Tower in Atlanta (680,000 square feet).

Further information regarding numerous past projects of the Franklin L. Haney Company, LLC is available at:

https://www.flhcompany.com/past-projects/

Nuclear Development is negotiating a term sheet and conditional loan commitment with the DOE Loan Programs Office.

B. Nuclear Developments External Financing Consultants Nuclear Development has used expert consultants to support various aspects of project funding and will continue to do so as needed and appropriate. Nuclear Development retained a prominent international financial institution as its primary financial advisor in regard to the rating, financing structure and financial plan for the project. MPR Associates, a well-regarded engineering firm with nuclear expertise, acted as independent engineers. MPR developed and validated the cost estimate and construction schedule. ICF International Inc., a global consulting services firm, advised on market conditions, and its consultants studied and validated the projected price for electricity in the relevant market.

ii.

Description of Anticipated Funding Methods and Sources This section provides a description of the anticipated funding methods and sources.

Page 11 of 14 Nuclear Development has applied for a loan from the U.S. Federal Finance Bank through the DOE Loan Guarantee Program. As noted earlier, Nuclear Development is negotiating the detailed loan guarantee term sheet and conditional loan commitment from the DOE Loan Programs Office. Nuclear Development expects the amount of this guarantee to cover 80% of the anticipated cost of completing construction of the Bellefonte Units.

Nuclear Development also anticipates that it will arrange for equity contributions for the remaining 20% of the cost of completing construction.

Nuclear Developments management team has an understanding of the complexities of financing a large nuclear power plant, the challenges in raising capital, and the need for ensuring financing before resuming reactor construction. Members of Nuclear Developments management team expect to obtain a conditional loan commitment and possess the capacity to obtain the final loan guarantee and other funding necessary to complete construction of the Bellefonte Units.

6. Restricted Data This Application does not contain any Restricted Data or other classified National Security Information, and it is not expected that such information will become involved in Nuclear Developments licensed activities. However, in the event that such information does become involved, and in accordance with 10 CFR 50.37, Agreement Limiting Access to Classified Information, Nuclear Development agrees that it will appropriately safeguard such information and will not permit any individual to have access to such information until the individual has been appropriately approved for such access under the provisions of 10 CFR Part 25, Access Authorization for Licensee Personnel, and/or Part 95, Facility Security Clearance and Safeguarding of National Security Information and Restricted Data.
7. Other Nuclear Regulatory Issues a.

Date of Completion In conformance with 10 CFR 50.33(h), Nuclear Development plans to complete construction of the Bellefonte Units after approximately a half year of planning, two years of engineering and four years of construction and refurbishment activity. Nuclear Development currently anticipates that both Units will be complete by 2024.

b. Antitrust The Energy Policy Act of 2005, Pub. L. No. 109-58, § 625, 119 Stat. 784 (2005), added subsection (c)(9) to Section 105 of the Atomic Energy Act, which states that the need for a NRC antitrust review does not apply to an application for a license to construct or operate a utilization facility or production facility under section 103 or 104b. that is filed on or after the date of enactment of this paragraph. For similar reasons as those stated in the Commissions

Page 12 of 14 decision in Kansas Gas & Electric Co. (Wolf Creek Generating Station), CLI-99-19, 49 NRC 441 (1999), transfers of construction permits are exempt from antitrust review. See also NUREG-1574, Rev. 2, Standard Review Plan on Transfer and Amendment of Antitrust License Conditions and Antitrust Enforcement at 2 (Dec. 2007) (ML072260035) (In light of the Wolf Creek decision, no [significant changes] analysis or antitrust review is undertaken when there is a license transfer application, regardless of whether it involves a direct or indirect license transfer.). Accordingly, the Atomic Energy Act does not require or authorize antitrust reviews of this Application.

c.

QA Program Upon consummation of the transfer, Nuclear Development will assume responsibility for the overall QA program requirements associated with maintaining ownership of Permits as specified for the Bellefonte Units in the TVA Nuclear Quality Assurance Program Description (QAPD),

Revision 33 (or later revision if affected). TVA will transfer responsibility for the QA program requirements at Bellefonte to Nuclear Development. Nuclear Development will establish a QA Program that meets the NRC requirements in 10 CFR Appendix B, including review and audit functions that will allow it to oversee SLN. Nuclear Development has retained Mr. John A.

Sablinski, who is experienced and fully qualified to act as QA Manager. In particular, he will perform this review and audit function. Mr. Sablinskis resume is provided in Enclosure 2.

SLN has a 10 CFR Appendix B, QA Program that meets NRCs requirements, and SLN will perform the day-to-day QA function under its plan. SLN also has developed a QA Plan specifically for Bellefonte, retaining the existing requirements of the TVA QA program. This plan has been reviewed and approved by Nuclear Development. A copy of the SLN QA Plan for Bellefonte is provided as Enclosure 5. Nuclear Development and SLN do not anticipate significant further changes to the existing QA program for the Bellefonte Units beyond conforming changes consistent with the license transfer, but any changes that do occur will be made by SLN in accordance with 10 CFR 50.54(a) with oversight provided by Nuclear Development for any changes.

d. QV Program Similarly, upon consummation of the transfer, Nuclear Development will assume authority and responsibility for the functions necessary to fulfill the QV requirements of the Permits as specified for the Bellefonte Units in the TVA Nuclear Quality Verification Program. TVA will transfer all of the current functions of the existing QV program at Bellefonte to Nuclear Development, which will establish its own QV organization and program. This QV organization and program will be supported by SLN for QV oversight and inspections. While the Bellefonte Units remain in deferred status, SLN and Nuclear Development do not anticipate any changes to the existing QV program for the Bellefonte Units beyond conforming changes consistent with the license transfer, but any changes that do occur will be made in accordance with 10 CFR 50.54(a). Nuclear Development plans to address the QV programs conclusions in any submittal it makes to the NRC prior to resuming construction activities.

Page 13 of 14 e.

Organizational Functions Upon consummation of the transfer, Nuclear Development will maintain the existing Bellefonte site organizational structure, personnel, procedures and programs in the same structure as is currently in place under TVA. This applies to the following functions related to maintenance of the deferred construction permit;

Document Control

Configuration Management

Training

Security

Corrective Action Program

Material Control

Equipment Maintenance f.

Insurance As required by 10 CFR 140.13, Nuclear Development will file with the Commission proof of financial protection (in the manner specified in 10 CFR 140.15) before the Commission issues it an operating license under 10 CFR Part 50 or a license under 10 CFR Part 70 authorizing ownership, possession and storage only of special nuclear material at the site for use as fuel in operation of the Bellefonte Units after issuance of an operating license under 10 CFR Part 50.

8. Requested Review Schedule and Other Required Approvals Nuclear Development respectfully requests that the NRC review and complete action expeditiously on this Application toward issuance of the NRC consent to the transfer of the Permits to Nuclear Development. In any event, Nuclear Development requests issuance of an Order and conforming license amendments by May 1, 2019. Nuclear Development is prepared to work closely with the NRC Staff to facilitate the Application's review.
9. Regulatory Safety Analysis The changes proposed for the Bellefonte Nuclear Plant Unit 1 are shown in Attachment 2, and clean pages are provided as Attachment 3 to the transmittal letter. Similar changes are provided for the Bellefonte Nuclear Plant Unit 2 in Attachments 4 (changes) and 5 (clean pages). The changes conform the Permits to reflect the proposed transfer of authority and responsibility for licensed activities under the Permits to Nuclear Development. Consistent with the generic determination in 10 CFR 2.1315, Generic determination regarding license amendments to reflect transfers, paragraph (a), the proposed conforming permit amendments involve no significant hazards consideration, because they do no more than conform the permits to reflect the transfer action.

The proposed permit amendments do not involve any change in the design or licensing basis, plant configuration, the status of the Bellefonte Units, or the requirements of the Permits.

Page 14 of 14 Therefore, the proposed approval does not: (1) involve an increase in the probability or consequences of an accident previously analyzed; (2) create the possibility of a new or different kind of accident from the accidents previously evaluated; or (3) involve a significant reduction in a margin of safety.

10. Environmental Considerations This Application and accompanying administrative amendments are exempt from environmental review under 10 CFR Part 51, Environmental Protection Regulations for Domestic Licensing and Related Regulatory Functions, because they fall within the categorical exclusion at 10 CFR 51.22(c)(21) (Approvals of direct or indirect transfers of any license issued by NRC and any associated amendments of license required to reflect the approval of a direct or indirect transfer of an NRC license). Accordingly, neither an Environmental Assessment nor an Environmental Impact Statement is required.
11. Summary In summary, the proposed transfer of the Permits to Nuclear Development will be consistent with the requirements of the Atomic Energy Act, NRC regulations, and regulatory guidance. Upon consummation of the transfer, Nuclear Development will maintain the Bellefonte Units in their deferred status while it proceeds expeditiously to complete engineering and design of the Bellefonte Units, with an ultimate goal of completing the construction of the Bellefonte Units.

There will be no adverse impact on public health and safety during either activity. The transfer of the Permits will not be inimical to the common defense and security and does not involve foreign ownership, control or domination. Nuclear Development therefore requests that the NRC consent to the transfer in accordance with 10 CFR 50.80 and approve the conforming administrative amendment pursuant to 10 CFR 50.92.

ENCLOSURE 1 BELLEFONTE NUCLEAR PLANT SITE PURCHASE AND SALES AGREEMENT

8th

TVA TRACT NO. XBEGP-3 IN WITNESS WHEREOF, the Parties have executed this First Amendment to Bellefonte Nuclear Plant Site Purchase and Sales Agreement as effective as of the day and year set forth above.

TENNESSEE VALLE NUCLEAR DEVELOPMENT, LLC By: ________________ _

Name: Franklin L. Haney

Title:

Sole Member and Manager First Amendment to Bellefonte Nuclear Plant Site Purchase and Sale Agreement Page 2 of 2 - Tennessee Valley Authority

TVA TRACT NO. XBEGP-3 First Amendment to Bellefonte Nuclear Plant Site Purchase and Sale Agreement Page 2 of 2 - Nuclear Development, LLC

ENCLOSURE 2 RESUMES OF KEY MANAGEMENT PERSONNEL William R. ( Bill ) McCollum, Jr.

Career Summary Seasoned executive with 44-year track record of delivering results in all phases of the electric utility business. Demonstrated success in building executive teams, developing business strategy and creating alignment with employees and stakeholders to achieve sustainable improved business results.

Experienced in performance turnaround as performance transformation leadership, as well as M&A organizational consolidation. Demonstrated performance in a progression of responsible leadership roles including C-level positions over nuclear operations, fossil operations, transmission and power supply functions.

Strong experience in construction management, project management and controls implementation and project oversight functions.

Education:

BS in Electrical Engineering, Georgia Tech; MS in Nuclear Engineering, Georgia Tech; MBA from UNC-Charlotte.

Training: NRC Senior Reactor Operator's License (Catawba Nuclear Station)

Registered Professional Engineer-NC #10382 SC #22547 Work Experience:

07/01/2012-Present Owner, McCollum Holdings, LLC Consultant to firms in the energy industry. Provides executive management consulting on nuclear industry issues, electric energy strategy issues and other energy matters.

05/01/2007-06/30/2012 Chief Operating Officer, Tennessee Valley Authority Responsible for all Generation, Transmission, Construction and River Operations functions, and associated support activities for the nations largest public power provider. Provide leadership for all operational functions as well as development and construction of new nuclear and conventional generation assets. Led an organization of over 9000 employees, a similar number of contractors, and an operating and routine capital budget of over $9B. Responsible for capital expansion projects with total budgets of over $5B. In addition to nuclear access clearances, held Top Secret clearance.

In this role, led a performance turnaround effort to re-tool the organization and assets, including significant reorganization, leadership change and introduction of a new management model to refocus the organization on operational excellence. Established improved labor relations, moving from an adversarial relationship to a collaborative relationship while gaining better management rights contract terms. Improved employee safety culture, resulting in recordable injury rates in top decile of industry.

10/24/2006-04/01/2007 Executive Vice-President and Chief Regulated Generation Officer, Duke Energy Corporation Responsible for leadership of Regulated Fossil-Hydro Generation, Engineering & Technical Services, Procurement, Regulated Bulk Power Marketing and New Generation Construction (Fossil and Nuclear). Provide Operational leadership to achieve and improve business results of Regulated operations in Carolinas and Midwest regions. As a direct report to the CEO, provide leadership in developing and executing business and regulatory strategy to provide earnings growth through cost reductions, operational excellence and capital management.

4/1/2006-10/24/2006 Group Vice-President, Regulated Fossil-Hydro Generation Responsible for operation of 21,000 MW of Fossil-fuel and Hydroelectric generating assets.

Provide leadership for development and execution of growth strategy and planning for environmental compliance while achieving operational excellence.

1/1/2005-4/1/2006 Vice-President, Strategic Planning and Business Development Primary Accomplishment: Led strategic planning efforts for Duke Power Company.

Implemented a much more structured and disciplined approach to forward generation and financial planning. Expanded the planning horizon from three to ten years, in order to capture key decision drivers. Led efforts to acquire non-nuclear generation assets to expand the power company generation portfolio.

11/01/2002-12/31/2004 VP, Nuclear Support Duke Power Company Annual O&M Budget: $150 Million Primary Accomplishment: Managed nuclear support functions, including Nuclear Fuels management, core design and fuels purchasing, Nuclear Supply chain services, Regulatory/ Self-Assessment functions and Engineering/ Scientific Services.

12/14/1997-10/31/2002 Site VP-Oconee Nuclear Station; Duke Power Company Annual O&M Budget: $215 Million Primary Accomplishment: Developed and implemented turnaround strategy to recover profitability while regaining regulatory confidence. Developed and led initiatives to change culture to support competitive success. Put in place a management team which would drive the organization to success. Implemented communications strategies to better engage workforce to support needed changes. Dramatically increased the discipline and structure for management decision-making. Led development of a five-year business and workforce plan to provide longer-term focus, rather than reactive approaches.

08/01/1995-12/14/1997 Site VP - Catawba Nuclear Station; Duke Power Company Annual O&M Budget: $160 Million Primary Accomplishment: Led continuous improvement in business focus and results.

Developed communication strategies to engage workforce in organizational improvement.

11/01/1991-08/01/1995 Station Manager, Catawba Nuclear Station, Duke Power Company Annual O&M Budget: $ 80 Million Primary Accomplishment: Led group through re-organization and selected people for key management roles. Improved business results while engaging workforce. Led development of an approach to human performance improvement which became the model for the nuclear function.

01/01/1989-11/01/1991 Maintenance Superintendent, Catawba Nuclear Station Duke Power Company 03/01/1987-01/01/1989 Superintendent of Station Services; Catawba Nuclear Station Duke Power Company Primary Accomplishment: Managed Human Resources function during times of first company-wide layoff. Coordinated selection and implementation planning for downsizing. Coordinated station communication planning and Employee Relations plans to ensure effective maintenance of employee engagement.

09/14/1974 03/01/1987 Held various roles in engineering, operations and project management within the Nuclear Generation function of Duke Power Company.

Professional Associations:

1.) B&W Owners Group Chairman of Executive Committee (2 years)

Led B&WOG during time of transition and challenges from industry consolidation and regulatory pressures.

2.) Member, INPO Executive Review Group (5 years)

Provided advice and consultation to management of INPO during time of significant changes. Often asked to work on subcommittees to provide assistance in shaping key process changes.

3.) Member, Nuclear Energy Institute Program and Resources Committee (2 years)

Developed plans for NEI involvement to improve industry position with regulators and legislators.

4.) Member, Electric Power Research Institute, Nuclear Power Council Led industry efforts to deal with significant materials reliability issues in BWRs and PWRs, managed oversight of programs to deploy industry resources to address key technical and regulatory issues.

5.) Board Member, National Academy for Nuclear Training Participated in and led Board reviews to determine accreditation of nuclear training programs for US, Canadian and South African power plants.

Civic Involvement:

1.) Board member, Chattanooga Aquarium:

Served as a member of the Board of Directors of the Chattanooga Aquarium, one of the largest aquarium and educational operations on the US. Helped lead expansion and redirection of the aquarium in response to changing economic conditions and competitive landscape.

2.) Board member, Chattanooga Chamber of Commerce:

The Chattanooga Chamber is a very active and effective force in recruiting new and expanded business into the Chattanooga area.

3.) Board member, Georgia Tech Nuclear and Radiological Health Physics Advisory Board 4.) Board Chair, Fluoride High Temperature Reactor External Advisory Board. Led an advisory Board for a multi-university government funded research project to move the design of an advanced Fluoride salt cooled reactor toward commercialization by resolving key technical barriers and analytical gaps.

1425 South Moore Road FRANKLIN L. HANEY COMPANY, LLC 3 Bethesda Metro Center Suite A a Tennessee Limited Liability Company SUITE 515 CHATTANOOGA, TENNESSEE 37412 Bethesda, Maryland 20814 423/265-0537 Fax 423/265-5422 202/479-1101 FAX 202/479-1106 FRANKLIN (FRANK) L. HANEY, JR.

Professional Credentials:

Bachelor of Science, University of Colorado, 1998 Experience:

President - Franklin L. Haney Company, LLC, Washington, DC (1999-Present)

Financial Analyst - Oakes, Lyman & Co. Limited, London, England (1998-99)

I am responsible for securing and structuring new projects as well as selling or restructuring the financing of existing project owned by the Franklin L. Haney Company and its affiliates. My expertise lies in locating new projects for the Company, working with the state and local governments on the projects and developing the business and financial structure in order to obtain the projects. I have secured over $1,000,000,000 in financing for such projects.

In addition, I handle the day to day operations of the Franklin L. Haney Company and its related entities along with managing the employees, which total approximately 100. The Company has downsized or sold many assets over the last 5 years which drastically reduced the number of employees under employment in order to free up cash flow and refocus our attention on new more profitable projects. I also manage and review all financial data for the Company, which includes the DC and Birmingham Office Buildings, the Colorado property, the Dulles Greenway Toll Road, the Miller/Coors Distributing Company and all family cash assets and securities.

Relevant Experience:

The Portals I and II Office Complex, Washington, DC The Dulles-Greenway Toll Road, Louden County, VA The Social Security Payment Center, Birmingham, AL The Miller/Coors Distribution Company, Northwest Arkansas The Chattanooga Computer Center, Chattanooga, TN The Chestnut Street Tower II, Chattanooga, TN The Dawsons Ridge Property, Castle Rock, CO Current Projects:

1) The Company is negotiating to purchase, finance and rehabilitate two (2) nuclear power plants for a combined potential financing of $12 billion.
2) I am currently renovating our 660,000 square foot building in Birmingham, Alabama. To date, I have negotiated and signed a thirty (30) year 300,000 square feet lease with the State of Alabama Department of Human Resources as of April 1, 2012. I am also in the final negotiations with the City of Birmingham to lease the remaining 360,000 square feet of the Birmingham Building to house The Cities Fire and Police departments.

Larry D. Blust T. 312.604.2672 F. 312.604.2673 lblust@hsplegal.com (mailto:lblust@hsplegal.com) 70 W. Madison Street, Suite 4000, Chicago, Illinois 60602 Larry Blust became a Partner of Hughes Socol Piers Resnick Dym, Ltd. in 2014. Mr. Blust has been in private practice since 1968, except for three years during which he served as a Staff Judge Advocate and Military Judge in the U.S. Air Force. Mr. Blust has extensive experience in virtually every area of corporate, tax, wealth, and real estate law. Specifically, Mr. Blust practices in the areas of mergers and acquisitions; tax reporting, consulting and controversies; gaming transactions; taxable and tax exempt bonds; infrastructure financing; other types of financing; fund structures; maritime matters; tax credits; entity structuring; wealthy family representation; and real estate law. Mr. Blust has also conducted a tax dispute practice in federal and state courts.

Prior to joining HSPRD, Mr. Blust was a partner at Barnes & Thornburg, where he served as the head of its Chicago Corporate and Business Department. Prior to that, Mr. Blust was a partner at Jenner & Block, where he was the head of the transitional Tax Department for over 20 years and was on the firm's Management Committee for 15 years.

Prior to receiving his law degree, Mr. Blust received a degree in accounting and an Illinois CPA Certificate and worked for PricewaterhouseCoopers.

EDUCATION University of Illinois College of Law (J.D. 1968)

Valedictorian University of Illinois Law Review University of Illinois at Urbana-Champaign (B.S. Accounting 1965)

Co-valedictorian ADMISSIONS BAR ADMISSIONS Illinois (1968)

COURT ADMISSIONS Illinois Supreme Court U.S. Court of Appeals for the Seventh Circuit U.S. District Court for the Northern District of Illinois Trial Bar Tax Court Court of Federal Claims PROFESSIONAL RECOGNITION AV Preeminent'" Rating by Martindale-Hubbell' Selected by peers as Super Lawyer" (2005 to Present)

Selectedby peers as Leading Lawyer in the areas of Closely & Privately Held Business Law, Corporate Finance Law, Gaming and Casino Law, Mergers & Acquisitions Law, and Tax Law: Business.

Law Member of Illinois CPA Board of Examiners (1978 1981)

MEMBERSHIPS / ASSOCIATIONS CIVIC / COMMUNITY Member, Board of Directors, Bailiwick Chicago Founding Director, Wisdom Bridge Theater (a not-for-profit theater)

Founding Director, Chicago Moving Company (a not-for-profit dance company)

Former Member, Board of Directors, Victory Gardens Theatre Former Chairman of Operations & Finance Committee and Member, Board of Directors, Augustana Hospital Former Member, Board of Directors, Lutheran General Hospital Former Member, Board of Directors, Lincoln Park Conservation Association Former President and Member, Old Town Triangle Association Member, Neighborhood Urban Renewal Advisory Board by appointment of Mayor Byrne and Mayor Daley Mr. Blust has also been active in Chicago neighborhood organizations and in zoning and planning matters MERGERS AND ACQUISITIONS Mr. Blust represents buyers and sellers in M&A transactions, including complicated tax structuring and cross border transactions. Some of his specialized niche areas are tax-exempt entity acquisitions and LLC acquisition structures minimizing tax on retained minority interests and Hart-Scott-Rodino filings.

Recent transactions include:

Sale of two consulting practices for large consulting firm Joint venture between state university and a publisher on financial index Acquisition of beer distributorship Sale of manufacturer with Canadian and European operations TAX REPORTING, CONSULTING, AND CONTROVERSIES Mr. Blust represents taxpayers at the audit, appellate, administrative hearing, and court levels regarding federal income, estate, and excise taxes and state and local income, sales, use, and franchise taxes. Recent matters include:

Settlement of TEFRA audit Settlement of Chicago lease and use tax matter at administrative hearing level Settlement of federal accumulated surplus tax case at appeals In addition to representing taxpayers in controversies, Mr. Blust counsels on situsing to minimize state and local taxes, handles unclaimed property audits and issues, develops structures for foreign clients for investments in the U.S. and negotiates and drafts tax reimbursement (secondment) agreements and tax allocation agreements regarding U.S. employees and operation located overseas. Mr. Blust also consulted for a former governor regarding Illinois tax legislation, including a possible gross receipts tax and regarding film tax credits.

TAXABLE AND TAX EXEMPT BONDS Mr. Blust has acted as bond counsel, borrower's counsel, underwriter's counsel, issuer's counsel, and credit enhancer's counsel on virtually every type of tax exempt and taxable bond. He was a pioneer on 501(c)(3) and Indian bonds and various synthetic bond and credit enhancement structures. Recent taxable bond transactions include the financing of a number of failed condominium project loans for several community banks by taxable variable rate demand bonds credit enhanced by Federal Home Loan Bank back to back letters of credit.

Recent tax-exempt bond transactions include:

Issuer's counsel on 2009 and 2010 Central DuPage Hospital bonds of $90 million and $240 million respectively Bond and borrower's counsel on $50,000,000 re-credit enhancement of housing bonds Several low and moderate income housing financings involving tax credits as well as tax exempt bonds INFRASTRUCTUREFINANCING Mr. Blust represents developers in structuring and financing infrastructure projects under public/private partnerships such as a toll road as to which he has represented the owners in over $2 billion in partnership financings and refinancings. In addition, he represented the same owners in $1 billion of mezzanine financing based on excess rated debt service coverage.

Mr. Blust also represents one of the largest developers and financers of federal and state office buildings in federal, state, and local government financings of buildings rented to government agencies in D.C. and other locations.

Mr. Blust is currently representing a client proposing to purchase and finance two partially completed nuclear reactors. This project also involves advanced nuclear facility production tax credits.

JOHN A. SLABINSKI

SUMMARY

My education includes a Bachelor of Science degree in Nuclear Science from the University of Maryland and a Management Senior Reactor Operator (SRO) certification with 29 years of verifiable experience in all aspects of Quality Assurance and project oversight. Competencies include:

  • Project Quality Assurance Manager of several nuclear projects
  • Completed LMJ International NQA-1 (2008 / 2009a) Lead Auditor Training Course April 2015 Completed Villanova Six Sigma Green Belt Training March 2014
  • Completed Villanova Lean Six Sigma Training July 2014
  • Integrated ASME Code, contractual, quality, and regulatory requirements into project specific Quality Assurance and Project Oversight Plans
  • Broad experience in developing, reviewing and writing quality programs, plans, and procedures
  • Served as a member of the Watts Bar Nuclear Unit 2 Joint Test Group EXPERIENCE:

Retired (11/15 - Present)

Tennessee Valley Authority (11/10 - 11/15)

Sr. Program Manager

  • Assigned to the Watts Bar Unit 2 Nuclear Plant for construction completion and preoperational testing
  • Assigned to the Bellefonte Nuclear project as the principle QA representative responsible for oversight and implementation of all quality assurance activities associated with the Construction Permit and Deferred Activity program in accordance with Generic Letter 87-15 including oversight of the fabrication of the replacement Integrated Economizer Once Through Steam Generators (IEOTSG) project activities.

Project Assistance Corporation (07/10 - 10/10)

QA Manager - Program Specialist

  • NQA-1, and
  • ASME Section III and Section VIII programs Science Applications International Corporation (10/05 - 07/10)

Sr. QA Engineer:

Graduated from the Flight Operations Training Academy and directly supported NASAs manned space program by developing and/or writing elements of the Quality Assurance requirements for:

  • Orion Quality Assurance Plan
  • Orion Contractor Surveillance Plan
  • Quality Certifications for Flight Readiness for all U.S. & Russian launches I also participated in the initial planning and coordinating meetings for:
  • Orion Vehicle Integration and Acceptance Plan
  • Crew Exploration Vehicle Avionics Integration Laboratory (CAIL)
  • Exploration Electrical Power Systems Test-bed (EEST) facility Bechtel Power Corporation (09/00 - 07/05)

Project Quality Assurance Manager:

Duties included the development of Project Quality Assurance Program Plans, comprehensive oversight and assessment plans, and more importantly the established the Quality interface between Bechtels Management team and the clients quality and management organization at the following projects:

  • Bruce A, Units 1 & 2 Steam Generator Replacement Project, Ontario, Canada (Proposal Team)
  • Browns Ferry (BFN) Unit 1 Restart

Operations Staff Specialist:

Performed oversight of all aspects of Plant Operations and Reactor Engineering activities including the planning, leading, and participation in performance and compliance based audits. These activities also assessed the audited departments ability to perform internal self-assessments and verified that local, state, and federal commitments were being met. Areas of responsibility included:

  • Reactor Plant Startup, Operation, and Shutdown
  • Reactor Initial Criticality and Low Power Physics Testing
  • Reactor Engineering
  • Representative to the STPEGS Plant Operations Review Committee (PORC) for 10 years
  • Served as a member of the STPEGS Independent Safety Evaluation Group (ISEG) for 7 years Engineering Staff Specialist:

Responsibilities included participation in Safety System Functional Inspections focusing on independent engineering and safety assessments of high-risk systems critical to reactor safety including any subsequent impact on the surrounding population, environment, and the facility Quality Engineering Supervisor:

Responsibilities included the supervision of the Nuclear Assurance verification of Licensing Event Reports (LER),

all correspondence with the Nuclear Regulatory Commission (NRC), plant configuration management, and site design engineering products Project Quality Control Supervisor:

Responsibilities included the supervision of all Electrical, I&C, Mechanical and NDE inspection activities Bechtel Power Corporation (02/78 - 11/85)

Department Administrator:

Functioned as the quality representative for the project manager and was responsible for the preparation of project review presentations for executive management and was responsible for the oversight of the configuration management databases.

Field Engineering Supervisor:

Responsible for the management of all aspects of the Clients Quality Assurance Program including the planning, implementation, and supervision of Electrical, I&C, Mechanical, and ASME Section XI, testing and inspection activities including the preparation, review, and administration of all documentation associated with these activities.

United States Navy - Honorable Discharge (1972 - 1978)

Navy Nuclear Reactor Operator:

SSN - 595 Responsible for the operation of the nuclear reactor during startup, shut down, normal and emergency conditions. Collateral duties included the testing, troubleshooting, and repair of all reactor plant monitoring, control, and safety systems.

Navy Nuclear Work Coordinator:

USS Dixon Responsible for the planning and implementation of work packages and procedures for the removal, repair, reinstallation, and testing of major mechanical components in the reactor plants of nuclear submarines.

EDUCATION, TRAINING, and CERTIFICATIONS Bachelor of Science degree in Nuclear Science 08/28/1993 University of Maryland, College Park, MD, GPA 4.0, Class Rank 1 in 482

  • Completed LMJ International NQA-1 Lead Auditor Training Course (2012 Criteria) 04/17/2015 Completed Villanova Six Sigma Green Belt Training March 2014 Complete Villanova Lean Six Sigma Training July 2014 RABQSA ISO 9001-2000 / AS9100 Lead Auditor Training 11/17/2006 No. PL/RAB/AS/010/11/17/07 Graduated from the United Space Alliance, Flight Operation Training Academy 03/06/2006 American Welding Society, Certified Welding Inspector, QCI-88 and QCI-96, Certificate No. 95090931 08/01/1998 L. Marvin Johnson and Associates, INC., Professional Quality Assurance Lead Auditor for Commercial, Government, and Nuclear Industries 12/05/1997 American Society for Quality, Quality Auditor 06/28/1996 Management Senior Reactor Operator (SRO) Certification, STPNOC 04/01/1994 Executive Media Communications / Public Relations Training Wixted, Pope, Nora, Thompson, & Associates 06/10/1994 General Physics Corporation, Performance Based Auditing Techniques 04/11/1990 Current U. S. Passport June 2020 Honorable Discharge, U.S. Navy 01/25/1978 ENCLOSURE 3 REQUEST FOR EXEMPTION REGARDING FINANCIAL QUALIFICATIONS APPLICABLE TO APPLICATION TO TRANSFER CONSTRUCTION PERMITS CPPR-122 AND CPPR-123

Bellefonte Nuclear Station, Units 1 and 2 Docket Nos. 50-438 and 50-439 Request for Exemption Regarding Financial Qualifications Applicable to Application to Transfer Construction Permits CPPR-122 and CPPR-123 Nuclear Development LLC (Nuclear Development) submits this request to the U.S. Nuclear Regulatory Commission (NRC) for an exemption from the financial qualification (FQ) requirements for construction permit transfers in 10 CFR 50.80(b)(1)(i), 50.33(f) and Part 50, Appendix C, as applied to its construction permit transfer application (Transfer Application) for Bellefonte Nuclear Station, Units 1 & 2 (Bellefonte Units).

As explained further below, this exemption request is being filed in accordance with:

Staff RequirementsSECY-13-0124Policy Options for Merchant (Non-Electric Utility) Plant Financial Qualifications (April 24, 2014) (ML14114A358);

SECY-15-0123, Staffs Statement in Support of the Uncontested Hearing for Issuance of Combined Licenses for the South Texas Project, Units 3 and 4, at pages 14-16 (September 30, 2015) (ML15176A532); and

Financial Qualifications for Reactor Licensing Rulemaking; Regulatory Basis Document (Oct. 2016) (ML15322A185).

On November 22, 2013, the NRC Staff issued SECY-13-0124, recommending that the Commission modify the FQ requirements of 10 CFR Part 50. The Commission agreed and, in the Staff Requirements Memorandum (SRM), directed the Staff to engage in a rulemaking to amend the FQ requirements in 10 CFR Part 50 to establish requirements similar to the FQ requirements in 10 CFR Part 70. Upon completion of the rulemaking, applicants could propose the use of license conditions to establish financial qualifications.

In the SRM authorizing the rulemaking, the Commission also stated that the Staff should consider utilizing an exemption process during the pendency of the rulemaking. On February 12, 2016, the Commission issued Combined Operating Licenses for South Texas Project, Units 3 and 4, a merchant plant. The South Texas Project application relied on an exemption from FQ requirements, based on the direction of the Commission in SRM-SECY-13-0124 and the draft regulatory basis document.

Nuclear Development requests that the NRC grant an exemption as contemplated in the SRM. Specifically, Nuclear Development requests an exemption from the FQ requirements in 10 CFR 50.80(b)(1)(i), 50.33(f) and 10 CFR Part 50, Appendix C, to allow use of a FQ standard appropriate for a partially-constructed facility, and similar to that contained in 10 CFR Part 70, including the use of license conditions, as applicable to the NRCs review of its Transfer Application.

A.

Background and Purpose Nuclear Development has submitted to the NRC an application to transfer Construction Permit Nos. CPPR-122 and CPPR-123 for the Bellefonte Units from the current holder of the permits, Tennessee Valley Authority, to Nuclear Development. Section 5 of the Transfer Application addresses the FQ of Nuclear Development.

The FQ requirements for construction permit and combined license transfers have presented a challenge because Bellefonte Units would be merchant plants, i.e., Nuclear Development does not have the benefit of traditional cost of service rate regulation and has had difficulty arranging for financing for construction prior to transfer of the construction permits. To resolve this issue, Nuclear Development proposes the use of a license condition requiring financial closing of a Project Finance prior to beginning construction, which would provide the reasonable assurance that is required for the NRC Staff to grant the transfers.

SECY-13-0124 discussed new approaches to evaluating FQ requirements for merchant plants. The Staff recommended that the Commission engage in rulemaking to modify the FQ requirements in 10 CFR Part 50. On April 24, 2014, the Commission issued a Staff Requirements Memorandum (SRM) for SECY-13-0124, which accepted the Staff s recommendations to initiate a rulemaking to amend the FQ requirements of 10 CFR Part 50 in order to make them similar to the FQ standards in 10 CFR Part 70. The Commission described the rulemakings objective as creating a FQ requirement in Part 50 that approximates, as appropriate, the approach currently used for 10 CFR Part 70 applications, but does not reduce the standard of review below that of appears to be financially qualified. Upon completion of the rulemaking, license applicants would be allowed to propose use of license conditions to address financial qualifications. The Commission also directed the Staff to consider utilizing an exemption process to address existing and emergent cases, as appropriate and necessary, during the pendency of the rulemaking process and that anticipates the outcome of the proposed changes to the current financial qualification regulations.

In April 2015, the NRC Staff issued Proposed Financial Qualifications Requirements Included in the Draft Regulatory Basis for the Rulemaking on Financial Qualifications for Reactor Licensing (Draft Regulatory Basis) (ML15111A270). The Draft Regulatory Basis summarized a new reactor FQ standard (to be adopted through rulemaking and regulatory guidance) to replace the current standard, which requires the applicant to provide reasonable assurance of obtaining the funds necessary to construct the reactor, with a Part 70-type standard, in which the applicant appears to be financially qualified. The Draft Regulatory Basis contemplated satisfaction of this standard through submission of: (1) a construction cost estimate, (2) a financial capacity plan, and (3) proposed license conditions.

On February 12, 2016, the Commission issued a Combined Operating License for South Texas Project, Units 3 and 4, a merchant plant. The South Texas Project application relied on an exemption from FQ requirements, based on the direction of the Commission in SRM-SECY-13-0124 and the Draft Regulatory Basis Document. In October 2016, the NRC issued the Final Regulatory Basis Document for the rulemaking: Financial Qualifications for Reactor Licensing Rulemaking; Regulatory Basis Document (Oct. 2016)

(ML15322A185) (Regulatory Basis). The final version did not materially alter the bases underpinning the rulemaking or the NRCs exemption for the South Texas Project.

Under 10 CFR 50.12, the Commission has the authority to issue specific exemptions from application requirements. As discussed in Section C below, the exemption would meet the standards in 10 CFR 50.12 for such an exemption, namely: (l) it is authorized by law; (2) it will not present an undue risk to the public health and safety; (3) it is consistent with the common defense and security; and (4) special circumstances are present.

B.

Requested Exemption and Proposed License Conditions Section 50.80(b)(1)(i) requires construction permit transfer applications to provide as much of the information described in Sections 50.33 and 50.34 of this part with respect to the identity and technical and financial qualifications of the proposed transferee as would be required by those sections if the application were for an initial license. 10 CFR 50.33(f) in turn requires applicants to state information sufficient to demonstrate to the Commission the financial qualification of the applicant to carry out... the activities for which the permit or license is sought. More specifically, under Section 50.33(f)(1), the applicant must show that it possesses or has reasonable assurance of obtaining the funds necessary to cover estimated construction costs and related fuel cycle costs, and shall indicate the source(s) of funds to cover these costs. Additionally, Appendix C to Part 50 specifies the types of financial data and other information necessary to demonstrate satisfaction of the requirements in 10 CFR 50.33(f).

As explained above, Nuclear Development requests an exemption from the FQ requirements in 10 CFR 50.80(b)(1)(i), 50.33(f), and Part 50, Appendix C, as applicable to its Transfer Application, and proposes the use of the following standards:

As to possessing and maintaining a partially-constructed facility: The applicant possesses or has reasonable assurance of obtaining the funds necessary to cover estimated costs of possessing and maintaining the facility prior to resuming construction.

As to resuming and completing construction: The applicant appears to be financially qualified to complete construction of the facility.

Under the exemption, Nuclear Development would demonstrate its financial qualification to possess and maintain a partially-constructed facility by submitting an estimate of the costs of possessing and maintaining the facility prior to resuming construction, and indicating the source(s) of funds to cover those costs. Nuclear Development would further demonstrate its financial qualification to complete construction of the facility by submitting an estimate of the cost of completing construction, a financial capacity plan, and the following ministerial license condition:

The licensee will notify the NRC at least 120 days prior to its anticipated date of resuming construction that the license condition has been fulfilled and that the following are available for inspection:

An updated cost estimate for completion of construction;

Documentation justifying any material variances from the cost estimate provided in the Transfer Application; and

Documentation demonstrating that the licensee has secured financing to fund the updated cost estimate for the completion of construction. This documentation will include operative closing documents, and may include documented proof of parent and affiliate assurances, or capital from other sources (as required to close the financing) that reflect financing for the project.

This approach will preserve financial qualification information in the licensing basis for Bellefonte Units, and will be consistent with NRCs monitoring of the potential for financial distress during construction.

C.

Information Required by 10 CFR 50.12(a)

Section 50.12(a) states that the NRC may grant exemptions that are authorized by law, will not present an undue risk to the public health and safety, and are consistent with the common defense and security. In addition, the NRC will not consider granting an exemption unless special circumstances are present. As demonstrated below, this exemption request satisfies the provisions in 10 CFR 50.12(a).

1.

The exemption is authorized by law The Commission has the authority to issue Nuclear Developments requested exemption.

The exemption would not conflict with any provision of the Atomic Energy Act (AEA) or any other law.

In particular, the NRC has broad discretion to evaluate financial qualifications, as provided in Section l82a of the AEA. The Commission itself has observed that the AEA does not impose any financial qualification requirement; it merely authorizes the Commission to impose such financial requirements as it may deem appropriate. Public Service Company of New Hampshire (Seabrook Station Units 1 & 2), CLI-78-1, 7 NRC 1, 9 (1978). Federal courts have agreed, finding that [the AEA] gives the NRC complete discretion to decide what financial qualifications are appropriate. New England Coalition v. NRC, 582 F.2d 87, 93 (1st Cir. 1978). Therefore, the exemption is authorized by law.

2.

The exemption does not present an undue risk to the public health and safety As explained above, the exemption would require demonstration that Nuclear Development is financially qualified to possess and maintain a partially-constructed facility; furthermore, license conditions would require, prior to resuming construction of Bellefonte Units, that Nuclear Development provide documentation demonstrating that it has secured financing to meet the updated cost estimate for the project. If the necessary funding is not secured, the plant will not be constructed, thereby ensuring that the exemption will not present a nuclear safety issue. Consequently, the exemption presents no undue risk to the public health and safety.

3.

The exemption is consistent with the common defense and security The exemption only pertains to the FQ requirements for Bellefonte Units and will not authorize the possession of licensed material or pertain to any NRC security requirements that apply to Bellefonte Units. Furthermore, as explained above, the license condition would require, prior to construction of Bellefonte Units, that Nuclear Development provide documentation demonstrating that it has secured financing to meet the updated cost estimate for the project. Those conditions ensure that the common defense and security will not be impacted. Therefore, the exemption is consistent with the common defense and security.

4.

Special circumstances are present Section 50.12(a)(2) states that special circumstances are present whenever any of six listed circumstances exist:

(i)

Application of the regulation in the particular circumstances conflicts with other rules or requirements of the Commission; or (ii)

Application of the regulation in the particular circumstances would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule; or (iii)

Compliance would result in undue hardship or other costs that are significantly in excess of those contemplated when the regulation was adopted, or that are significantly in excess of those incurred by others similarly situated; or (iv)

The exemption would result in benefit to the public health and safety that compensates for any decrease in safety that may result from the grant of the exemption; or (v)

The exemption would provide only temporary relief from the applicable regulation and the licensee or applicant has made good faith efforts to comply with the regulation; or (vi)

There is present any other material circumstance not considered when the regulation was adopted for which it would be in the public interest to grant an exemption. If such condition is relied on exclusively for satisfying paragraph (a)(2) of this section, the exemption may not be granted until the Executive Director for Operations has consulted with the Commission.

The following special circumstances apply here:

Section 50.12(a)(2)(ii) applies because the exemption will be consistent with the objective of the FQ requirements in Part 50, which is to protect public health and safety. As provided in 33 Fed. Reg. 9,704 (July 4, 1968), the fundamental purpose of the financial qualifications provisions... is the protection of the public health and safety and the common defense and security. The regulations practical objective is to prevent safety lapses from underfunded projects. Because the exemption will ensure that the applicant is financially qualified to possess and maintain a partially-constructed facility prior to resuming construction, and license conditions will ensure that construction of the project only proceeds once adequate funding is secured, the exemption satisfies the underlying purpose of the FQ requirements in Part 50. Consequently, the special circumstance described in 10 CFR 50.12(a)(2)(ii) applies to this exemption request.

Section 50.12(a)(2)(vi) applies because there is a material circumstance not considered when the regulation was adopted for which it would be in the public interest to grant an exemption. Specifically, the Commission in the SRM on SECY-13-0124 has approved the Staffs request to initiate a rulemaking to amend the FQ requirements of 10 CFR Part 50 and to use FQ standards similar to those contained in 10 CFR Part 70, including allowance for the use of license conditions addressing financial qualifications. The Commission further authorized the Staff to consider issuing exemptions for applications reviewed during the pendency of the rulemaking, such as Bellefonte Units. Consequently, the special circumstance described in 10 CFR 50.12(a)(2)(vi) applies to this exemption request.

D.

Conclusion In accordance with the Commission's statements in the SRM for SECY-13-0124 and the Regulatory Basis, Nuclear Development seeks an exemption from the NRCs FQ requirements as applicable to the Transfer Application. The exemption would enable the applicant to demonstrate its financial qualification to possess and maintain a partially-constructed facility prior to resuming construction, and establish financial qualifications for resuming construction through the use of license conditions that would require, prior to resuming construction of Bellefonte Units, that Nuclear Development provide documentation demonstrating that it has secured financing to meet the updated cost estimate for the project. The exemption request satisfies the factors in 10 CFR 50.12. For the foregoing reasons, Nuclear Development respectfully requests that the NRC grant the requested exemption from the requirements of 10 CFR 50.80(b)(1)(i), 50.33(f) and Part 50, Appendix C, as applicable to the Transfer Application.

ENCLOSURE 4 PROJECTED TOTAL PROJECT COSTS FOR BELLEFONTE UNITS 1 & 2 (NON-PROPRIETARY) 1 Costs in $MM's Unit 1 Unit 2 Total Construction Costs Contingency & Escalation Total Construction Costs Land Costs Power Uprate Total Construction Interest (DOE)

Construction Interest (Equity)

Total Construction interest Total Costs

CITY OF WASHINGTON

)

) SS.

)

DISTRICT OF COLUMBIA 10 CFR 2.390 AFFIDAVIT OF WILLIAM R. MCCOLLUM, JR.

William R. McCollum, Jr., being duly sworn according to law deposes and says:

I am Chief Nuclear Officer, Nuclear Development LLC do hereby affirm and state:

1. I am authorized to execute this affidavit on behalf of Nuclear Development LLC

("Nuclear Development");

2.

Nuclear Development requests that Enclosure 4P labeled "CONFIDENTIAL INFORMATION SUBMITTED UNDER 10 CFR 2.390", be withheld from public disclosure under the provisions of 10 CFR 2.390(a)(4).

3. Enclosure 4P contains confidential commercial fmancial information, the disclosure of which would adversely affect Nuclear Development.

4.

This information has been held in confidence by Nuclear Development. To the extent that Nuclear Development has shared this information with others, it has done so on a confidential basis.

5. Nuclear Development customarily keeps such information in confidence, and there is a rational basis for holding such information in confidence. The information is not available from public sources and could not be gathered readily from other publicly available information.

6.

Public disclosure of this information would cause substantial harm to Nuclear Development's business interests because such information has significant commercial value to Nuclear Development and its disclosure could adversely affect Nuclear Development.

ENCLOSURE 5 QUALITY ASSURANCE PLAN FOR BELLEFONTE UNITS 1 & 2

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date:

2018.10.18 Page 1 of 73

Title:

Bellefonte Project - Quality Assurance Plan

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 2 of 73

Title:

Bellefonte Project - Quality Assurance Plan RECORD OF REVISION Revision Number Date Description Authorizing Signatures Prepared By:

Reviewed By:

Approved By:

PA 2018.06.29 Release for review and comment Ashok V Wagadarikar Kevin Jones Marie Gillman John Obuch N/A PB 2018.09.18 Incorporated QA comments, revised to add section 19, Deferred Construction Permit for Bellefonte Ashok V Wagadarikar Marie Gillman N/A 00 2018.10.18 Initial Issue Ashok V Wagadarikar Marie Gillman John Obuch

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 3 of 73

Title:

Bellefonte Project - Quality Assurance Plan Table of Contents 1

Project Information..........................................................................................................................7 1.1 Customer Information...............................................................................................................7 1.2 Scope of Work.........................................................................................................................7 1.3 Scope of this QA Plan..............................................................................................................7 1.4 Description of Plant Facilities...................................................................................................9 1.5 Project Scope...........................................................................................................................9 1.6 Project Quality Assurance Program Overview........................................................................10 1.7 Nuclear Safety Culture...........................................................................................................11 1.8 Authority to Stop Work...........................................................................................................11 1.9 Organization...........................................................................................................................11 1.10 Organizational Structure........................................................................................................12 1.11 Organizational Independence................................................................................................12 1.12 Responsibilities......................................................................................................................12 Project Director...............................................................................................................12 Project Controls Manager...............................................................................................13 Project Quality Assurance Manager................................................................................13 Project Quality Control Manager.....................................................................................14 Project Engineering Manager..........................................................................................14 Project Construction Manager.........................................................................................15 Project Procurement Manager........................................................................................15 Project Training Manager................................................................................................16 Project Onboarding Training Manager............................................................................16 2

Quality Assurance Program..........................................................................................................17 2.1 Personnel Indoctrination and Training....................................................................................18 Personnel Qualification...................................................................................................18 Qualification of Engineering Personnel............................................................................19 3

Design Control..............................................................................................................................20 3.1 Control of Design and Interfaces............................................................................................20 3.2 ND Enterprises Asset Management.......................................................................................21 3.3 Design Planning.....................................................................................................................21 3.4 Engineering Design Changes (EDCs)....................................................................................23 Design inputs..................................................................................................................23 Design Process...............................................................................................................23 Design Verification..........................................................................................................24 Design Change Control...................................................................................................27 Commercial Grade Dedication........................................................................................27 Human Factors Engineering............................................................................................28 4

Procurement Document Control....................................................................................................29 4.1 General Requirements...........................................................................................................29 Procurement Planning.....................................................................................................30 4.2 Content of Procurement Documents......................................................................................31

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 4 of 73

Title:

Bellefonte Project - Quality Assurance Plan General Requirements....................................................................................................31 Scope of Work................................................................................................................31 Technical Requirements.................................................................................................31 Quality Assurance Program Requirements.....................................................................32 Right of Access...............................................................................................................32 Documentation Requirements.........................................................................................32 Non-conformances..........................................................................................................32 Spare and Replacement Parts........................................................................................32 4.3 Procurement Document Review.............................................................................................33 4.4 Procurement Document Changes..........................................................................................33 5

Instructions, Procedures and Drawings.........................................................................................34 6

Document Control.........................................................................................................................35 6.1 General Requirements...........................................................................................................35 Quality Assurance Documentation..................................................................................35 Engineering Documentation............................................................................................35 Supplier Documentation..................................................................................................35 6.2 Document Identification and Preparation................................................................................36 6.3 Document Changes...............................................................................................................36 7

Control of Purchased Items and Services.....................................................................................37 7.1 General Requirements...........................................................................................................37 7.2 Procurement Planning............................................................................................................38 7.3 Supplier Evaluation and Selection..........................................................................................40 Supplier Evaluation for Bid Purpose................................................................................40 Supplier Evaluation Prior to Purchase Order Award........................................................41 7.4 Bid Evaluation........................................................................................................................41 7.5 Qualification of Suppliers........................................................................................................42 7.6 Control of Supplier Generated Documents.............................................................................43 7.7 Acceptance of Items or Services............................................................................................43 General Requirements....................................................................................................43 Methods of Acceptance...................................................................................................44 Certificate of Conformance..............................................................................................44 Source Verification..........................................................................................................44 Receiving Inspection.......................................................................................................44 Post Installation Testing..................................................................................................45 Acceptance of Services Only..........................................................................................45 7.8 Control of Supplier Non-Conformance....................................................................................45 7.9 Commercial Grade Items and Services..................................................................................46 7.10 Purchase Order Administration..............................................................................................47 7.11 Purchase Order Completion...................................................................................................47 8

Identification and Control of Items.................................................................................................48 8.1 General Requirements...........................................................................................................48 8.2 Identification Methods............................................................................................................48 Item Identification............................................................................................................48 Physical Identification......................................................................................................48 8.3 Specific Requirements...........................................................................................................49

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 5 of 73

Title:

Bellefonte Project - Quality Assurance Plan Identification and Traceability of Items............................................................................49 Limited Life Items............................................................................................................49 Maintaining Identification of Stored Items........................................................................49 9

Control of Processes.....................................................................................................................50 9.1 Process Control.....................................................................................................................50 9.2 Special Processes..................................................................................................................51 Welding Procedures........................................................................................................51 Heat Treatment Procedures............................................................................................51 Nondestructive Examination Procedures.........................................................................52 Special Processes Not Covered by Existing Codes and Standards.................................52 Source Surveillance on Special Processes.....................................................................52 10 Inspection......................................................................................................................................53 10.1 General Requirements...........................................................................................................53 10.2 Inspection Requirements........................................................................................................53 10.3 Inspection and Hold Points.....................................................................................................53 10.4 Inspection Planning................................................................................................................53 Planning..........................................................................................................................53 Sampling (Non ASME Work)...........................................................................................53 10.5 In Process Inspection.............................................................................................................53 10.6 Final Inspections....................................................................................................................54 Resolution of Non-conformance......................................................................................54 Inspection Requirements................................................................................................54 Modifications, Repairs, or Replacement..........................................................................54 10.7 Records.................................................................................................................................54 11 Test Control..................................................................................................................................55 11.1 General Requirements...........................................................................................................55 11.2 Test Requirements.................................................................................................................55 11.3 Test Procedures.....................................................................................................................55 11.4 Performance of the Component Pressure Test......................................................................56 11.5 Test Results...........................................................................................................................56 11.6 Test Records..........................................................................................................................56 11.7 Certification of ASME Code Data Report and Application of Certification Mark......................57 12 Control of Measuring and Test Equipment....................................................................................58 12.1 General Requirements...........................................................................................................58 12.2 Selection................................................................................................................................58 12.3 Calibration and Control..........................................................................................................58 12.4 Records.................................................................................................................................59 12.5 Calibration Services...............................................................................................................59 13 Handling, Storage and Shipping....................................................................................................60 14 Inspection and Test Status............................................................................................................61 14.1 General Requirements...........................................................................................................61 14.2 Status.....................................................................................................................................61 15 Control of Nonconforming Items and Services..............................................................................62 15.1 General Requirements...........................................................................................................62 16 Corrective Action...........................................................................................................................63

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 6 of 73

Title:

Bellefonte Project - Quality Assurance Plan 16.1 General Requirements...........................................................................................................63 16.2 Corrective Action....................................................................................................................63 16.3 Supplier Corrective Action Request........................................................................................64 17 Quality Assurance Records...........................................................................................................65 17.1 General Requirements...........................................................................................................65 17.2 Generation of Records...........................................................................................................65 17.3 Authentication of Records......................................................................................................65 17.4 Classification..........................................................................................................................65 17.5 Receipt, Control and Retention of Records............................................................................66 17.6 Storage..................................................................................................................................66 17.7 Retention...............................................................................................................................67 17.8 Maintenance of Records........................................................................................................67 17.9 Records Turnover..................................................................................................................67 18 Audits............................................................................................................................................68 18.1 General Requirements...........................................................................................................68 19 Bellefonte Deferred Construction Permit.......................................................................................69 19.1 General Requirements...........................................................................................................69 19.2 Scope/Applicability for Current Activities Deferred Plant Status.............................................69 19.3 Organization...........................................................................................................................71 Bellefonte Owner, Nuclear Development.........................................................................71 Chief Nuclear Officer, SNC-Lavalin Nuclear (CNO).........................................................71 Project Director, BLN Project..........................................................................................71 Director, Quality Assurance SNC-Lavalin Nuclear...........................................................71 19.4 Deferred Permit Procedures...................................................................................................72 Organization...................................................................................................................72 QA Program....................................................................................................................72 Document and QA Record Control..................................................................................72 Corrective Action Program..............................................................................................72 Material Storage and Handling........................................................................................72 Equipment Maintenance.................................................................................................72 Site Security....................................................................................................................72 19.5 Audits.....................................................................................................................................73 19.6 Plant Equipment Policy..........................................................................................................73

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 7 of 73

Title:

Bellefonte Project - Quality Assurance Plan 1

Project Information 1.1 Customer Information Project Name:

Bellefonte Project Project Number:

152918 Customer:

Nuclear Development, LLC, ND, Bellefonte Nuclear Plant, Hollywood, Alabama Customer

Contact:

Frank Haney Telephone: On record 1.2 Scope of Work SNC-Lavalin Nuclear (USA) Inc., a subsidiary of SNC-Lavalin Nuclear Inc. (SLN), is contracted to complete Bellefonte Nuclear Generating Plant Units 1 & 2.

The Bellefonte (BLN) Project shall be executed in four (4) distinct phases as described in the EPC Agreement for Bellefonte Project. The Phases are:

Design - complete and or upgrade all system designs and complete required engineering analysis to support all regulatory and code requirements.

Construction - install all required components

Start Up - testing of all components, systems and interfaces between systems

Commercial Operation - plant operation 1.3 Scope of this QA Plan This QAP describes the 10 CFR50 App B compliant QA Program to be applied to the Bellefonte Nuclear Generating Plant Units 1 & 2 plant facilities (as described under section 1.4) during the period of deferral of the construction period.

The QAP covers a description of the planned activities, organizational responsibilities and procedural controls that apply to the verification of construction status, maintenance and preservation of equipment and materials and the retention and protection of quality assurance records.

The QAP covers the QA surveillance / oversight and requirements to maintain the Bellefonte NRC Deferred Construction Permit following transfer of the site from the Tennessee Valley Authority (TVA).and is commensurate with the commitments made to the NRC prior to start of construction activities.

This QA Plan and attendant procedures shall be revised significantly when regulatory approval is provided to transition the Bellefonte site permit from deferred to active construction status.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 8 of 73

Title:

Bellefonte Project - Quality Assurance Plan General Information:

The Bellefonte Nuclear Generating Plant (BLN) project scope will be to complete and upgrade the two partially completed reactor plants; Bellefonte Unit 1 and Unit 2. Design will involve ensuring all regulatory requirements and standard nuclear industry initiatives are addressed, equipment that has been removed is replaced, and any required upgrades are designed.

Construction will install all required plant components and refurbish existing equipment. Start Up testing will involve individual component and system testing, integrated system tests, hot functional testing, cold hydrostatic testing and reactor physics testing. Commercial operations will follow successful testing and plant synchronization to the grid. Schedule A of the Customers Purchase Agreement (PA) provides the Scope of Work and Technical Specifications for the Bellefonte Nuclear Power Plant Completion.

Note: Procedures which govern the completion of the Bellefonte plant will be prepared and issued during the course of the project, and with exception of QA procedure references, all other procedure references are to be considered draft. The existing Bellefonte implementation procedures in place at the site will be maintained and controlled under ND, with oversight provided by the SNC-Lavalin QA organization.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 9 of 73

Title:

Bellefonte Project - Quality Assurance Plan 1.4 Description of Plant Facilities The following is a brief description of the Bellefonte Nuclear Generating Plant Units 1 & 2.

NSSS: Framatome (formerly Babcock & Wilcox) 205 4-Loop Pressurized Water Reactor

Current Plant Capacity: 3,600 Megawatt Thermal, 1260 Megawatt Electric

Turbine: GE (formerly Brown Boveri) Steam Turbine (2LP / 1HP) and a hydrogen cooled electricity generator;

Natural Draft Cooling Towers;

Unit 1 was 90% physically complete in 1988. The resources required to complete BLN1 (time, manpower and capital) bring the current completion estimate to approximately 55%.

The Bellefonte site also contains a second identical unit that was completed to approximately 58% in 1988, and is currently estimated to be 35% complete.

1.5 Project Scope Except for those specific items as being provided by others, the scope shall include all necessary management, supervision, mobilization, project controls, administrative staff, home office support, engineering, design, construction, procurement, subcontract administration, project controls, human resources, specialty technicians, safety, fabrication, inspections, testing, qualified labor, materials, equipment, tools, supplies, consumables, services, oversight, ancillary facilities, demobilization, and all other items required to perform the Work as described in the Bellefonte contract.

The scope of the BLN Project includes engineering and construction services required to complete engineering, procurement, construction and testing as itemized, but not limited, to the list below.

Development of all required nuclear programs and plans to support completion of BLN-1,2

Complete all system designs ensuring all regulatory requirements are met

Complete all required engineering programs and analysis

Completion of engineering design to support required plant modifications and upgrades

Upgrade FSAR

Licensing activities required to support transition from deferred construction status to operating license

Completion of major projects:

i)

Steam generator replacement ii)

Turbine-generator upgrade iii)

Containment sump replacement iv) Switchyard upgrade v)

Security System Installation vi) Facility Building Construction

Construction activities to complete physical installation of mechanical, civil, electrical and instrument and controls components and systems:

i)

Replace equipment that has been removed ii)

Refurbish equipment that will be retained

Procurement of all equipment, safety and non-safety related, in accordance with required quality and code requirements

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 10 of 73

Title:

Bellefonte Project - Quality Assurance Plan

All testing required to ensure systems and components will meet design and safety requirements.

Field engineering in support of the construction scope

Materials management and warehousing for all material supplied

Production of Comprehensive Work Packages and Integrated Test Plans for all field work performed under scope

Production of closeout documentation for all field work performed 1.6 Project Quality Assurance Program Overview SNC-Lavalin Nuclear (USA) Inc., a subsidiary of SNC-Lavalin Nuclear Inc. (SLN), The SNC-Lavalin Nuclear (USA), Inc. (SLN) Quality Assurance program is the overall Quality Assurance Program for the project. The SLN Quality Assurance Program, as described in this Nuclear Quality Assurance Plan (QAP)

Complies with all applicable laws, follows prudent practice and is consistent with the requirements of the agreement between Nuclear Development LLC (ND) and SNC-Lavalin Nuclear Inc (SLN);

Includes provision for audits by ND (or NDs Representative) for compliance with the ND Project Quality Assurance Plan for the scope of work as per the agreement between ND and SLN; SNC-Lavalin Nuclear Inc., through SNC-Lavalin Nuclear (USA) Inc., will subcontract site fabrication and installation activities to qualified suppliers. The qualified suppliers shall implement and maintain a Quality Assurance program at the project site acceptable to SLN and ND. SLN shall maintain responsibility for all quality assurance requirements, including subcontracted activities and will perform oversight on activities performed by SNC-Lavalin and their suppliers in accordance with the Bellefonte Oversight Plan for the contracted SLN project work scope covering the following project activities:

Design (SLN scope)

Construction (Scope of a Sub-Supplier qualified by SLN)

Procurement (SLN scope)

Inspection and Testing (Scope of a Sub-Supplier qualified by SLN)

Handling and storage of nuclear materials and components (Warehousing) (Scope of a Sub-Supplier qualified by SLN)

Construction Work Packages (Scope of a Sub-Supplier qualified by SLN)

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 11 of 73

Title:

Bellefonte Project - Quality Assurance Plan 1.7 Nuclear Safety Culture Nuclear safety culture is defined as the core values and behaviors resulting from a collective commitment by leaders and individuals to emphasize safety over competing goals to ensure protection of people and the environment. The following Nuclear Safety Culture principles apply to the BLN Project:

Responsibility and authority for nuclear safety are well defined and clearly understood.

Reporting relationships, positional authority, and team responsibilities emphasize the overriding importance of nuclear safety;

Project team members are watchful for assumptions, anomalies, values, conditions, or activities that can have an undesirable effect on plant safety;

Communications maintain a focus on safety; Executive and senior managers are the leading advocates of nuclear safety and demonstrate their commitment both in word and action. The nuclear safety message is communicated frequently and consistently, occasionally as a stand-alone theme.

1.8 Authority to Stop Work SNC-Lavalin Nuclear QA and Contractor quality assurance and inspection personnel have the authority, and the responsibility, to stop work in progress which is not being done in accordance with approved procedures or where safety or structure, system or component integrity may be jeopardized. This extends to off-site work performed by suppliers furnishing safety-related materials and services to SNC-Lavalin.

1.9 Organization SNC-Lavalin Nuclear Inc. will have overall responsibility for Project Quality Assurance and will comply with SNC-Lavalin Nuclear Inc. Quality Assurance Manual 2206-01912-QM-0001. The Quality Assurance Manual is SNC-Lavalin Nuclear Inc.s commitment to meeting the Quality Assurance requirements of 10CFR50 Appendix B.

SNC-Lavalin Nuclear Inc., through SNC-Lavalin Nuclear (USA) Inc., will subcontract site engineering and construction activities to qualified suppliers, as required. The qualified suppliers shall implement and maintain a Quality Assurance program at the project site acceptable to SLN and ND. SLN shall maintain responsibility for all quality assurance requirements, including subcontracted activities.

This Bellefonte Project Nuclear QA Plan is considered a living document and will be revised, reviewed, and approved as changes are made.

The SNC-Lavalin Nuclear Inc. Quality Assurance Program is the overall Quality Assurance Program for the project. SNC-Lavalin and all direct suppliers to SNC-Lavalin Nuclear shall be qualified in accordance with requirements of this QAP. SLN shall plan and conduct surveillance on all activities performed by its sub-suppliers to assure adequate oversight of their performance.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 12 of 73

Title:

Bellefonte Project - Quality Assurance Plan The overall BLN Project organization shall be as defined in Bellefonte Project Execution Plan.

The project Organization Chart shall be maintained and updated through the life of the project by the Project Manager or the Deputy Project Manager. This does not preclude the Project Manager from producing multiple organization charts to completely define the project structure.

1.10 Organizational Structure Personnel performing activities on the BLN Project for all phases of project execution are shown in an integrated project organization chart that is developed and maintained through the life of the project by the BLN Project Director. This does not preclude the BLN Project Director from producing multiple organization charts to completely define the project structure.

The Project Organization charts will be reviewed periodically and will be filed separately by Document Control.

1.11 Organizational Independence For the BLN Plant, independence shall be maintained between the organization performing the checking (quality assurance and quality control) functions and the organizations performing the functions. This provision is not applicable to design review/verification.

1.12 Responsibilities This QAP defines responsibilities related to implementation of the Quality Program applicable to execution of BLN project.

The detailed responsibilities of the key SNC-Lavalin individuals are defined in the Bellefonte Project Execution Plan. All other individual responsibilities shall be as described in the other detailed plans referenced by Project Management Plan. All SNC-Lavalin personnel assigned to this project shall perform their assigned duties in compliance with the SNC-Lavalin Nuclear Inc. Quality Assurance program and under the direction of SNC-Lavalin Nuclear qualified personnel. Records of personnel qualifications shall be available for inspection by ND as required.

Project Director The Project Director reports to the SNC-Lavalin Chief Nuclear Officer and is responsible:

for the implementation and effectiveness of this quality assurance plan;

to develop and maintain the Project Organization Chart through the life of the project.

to ensure that personnel assigned to perform activities are trained, qualified and competent to perform their assigned tasks effectively;

for identifying Customer communication channels;

for obtaining, assessing, and issuing information gained from experience for design, construction, installation and commissioning activities;

for managing project staffing as necessary;

for reviewing Customers work request, tendering documents, contracts and associated documents, to determine that the requirements are defined and documented, and that SLNs resources and capability are adequate to meet the requirements;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 13 of 73

Title:

Bellefonte Project - Quality Assurance Plan

for assigning project resources appropriate for the work to be performed;

for ensuring that the completion assurance is performed.

Project Controls Manager The Project Controls Manager is responsible to manage all activities related to scheduling, planning, estimating, reporting, and cost control for the project.

Project Quality Assurance Manager The Project Quality Assurance Manager reports functionally to SNC-Lavalin Director, Quality Assurance and to the BLN Project Director for implementation of the Project QA program, as described in this QAP. The SLN Quality Assurance Manager shall have overall responsibility for implementing, monitoring compliance, and reporting project performance with respect to quality assurance.

The Quality Assurance Manager has responsibility to plan and execute surveillance on project activities assigned to be performed by SLNs qualified suppliers responsible for execution of construction work.

The Quality Assurance Manager shall be independent of cost and schedule considerations and has the authority to plan, establish, implement and maintain this Quality Assurance Plan and is the management representative who has authority and responsibility to resolve quality matters, and has the organizational freedom, along with those responsible for verification, audit and program review functions, to:

Identify and record quality problems and problems related to the effective implementation of this QAP;

Initiate, recommend, or provide solutions to such problems through designated channels;

Verify and confirm implementation and effectiveness of solutions;

Control further processing, delivery, or installation of a nonconforming item or service until a disposition has been obtained.

The Quality Assurance Manager and persons responsible for the verification, audit, and program review functions have direct access to a level of management necessary to ensure that appropriate actions are implemented.

The Quality Assurance Manager has a direct line of communication to the BLN Project Director and is assigned the responsibility, authority, and organizational freedom, to initiate, implement and control the Quality Assurance Plan and is responsible:

to represent the project team on all matters pertaining to quality;

for planning, establishing, documenting, and maintaining this quality assurance plan;

to direct the performance of internal and external quality audits;

for verification of purchased items and services for construction and installation work;

for planning and conducting oversight activities as necessary;

for providing indoctrination and training in this Quality Assurance Plan (QAP);

to ensure that trained, qualified, competent, and as required certified, personnel are assigned to perform quality related activities;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 14 of 73

Title:

Bellefonte Project - Quality Assurance Plan

to report to the Project Executive Committee, if requested, on the performance of the Quality Assurance Plan;

for acceptance of quality services;

for evaluating and ensuring contractors selected meet project quality requirements;

for reviewing and accepting of supplier furnished documents;

for providing support in ensuring satisfactory performance with regard to the Project Objectives.

Project Quality Control Manager The Project Quality Control Manager reports functionally to the Director, Quality Assurance and to the Project Construction Manager for execution of project quality control activities and functionally reports to SNC-Lavalin Nuclear Quality Manager.

The Quality Control Manager shall be responsible for:

Providing guidance to Quality Assurance Specialists assigned to the project.

Providing oversight of incoming, in-process, and final inspections on the project as detailed on the inspection and test plan and procedures.

Staffing QC positions for the project with suitably qualified individuals.

Providing support to project in ensuring satisfactory performance with regard to the project quality control objectives.

Ensure that quality control plans/checklist and records are prepared and maintained

Initiate, control and report nonconforming items during site installation phase;

Ensure that quality records are compiled in HD/HF and approved prior submission for acceptance

Providing on-job training of site inspection personnel on the quality project requirements.

Interfacing on matters relating to quality with the Customer as well as the Regulatory Authorities as requested by project QA Manager.

Project Engineering Manager The Project Engineering Manager reports to the BLN Project Director and is responsible for:

overall design control,

ensuring that design is defined, controlled and verified, and

ensuring availability of appropriate verification and validation of design analysis tools.

ensuring compliance with approved design, regulatory requirements, codes, standards and good engineering practices.

providing general direction for establishing technical, safety and quality standards for engineering deliverables.

reviewing and approving key technical documentation

monitoring the technical quality of engineering deliverables

providing assistance to engineering pertaining to codes, standards, regulatory requirements

technical liaison with customers regarding the technical quality of engineering services

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 15 of 73

Title:

Bellefonte Project - Quality Assurance Plan Lead Discipline Engineers are responsible to ensure that their staff performs design activities in accordance with applicable statutes, standards, codes, customer requirements, and corporate policies and procedures. Specific responsibilities include but are not limited to:

reviewing and approving the selection of design inputs,

correctly translating design input into specifications, drawings, procedures, instructions and other design documents,

ensuring appropriate quality standards are included in design documents and their selection is reviewed and approved,

selection and review for suitability of application of design methods, materials, parts, equipment, and processes that are essential to the safety-related functions of structures, systems and components,

making applicable information derived from operating experience available to appropriate design personnel

performing design analysis and verification;

assigning work activities to design staff and revise as required,

providing status reporting of work activities to Project Managers, or Vice Presidents, as

required,

monitoring staff performance to customer requirements Project Construction Manager The BLN Project Construction Manager reports to the BLN Project Director and is responsible for:

executing construction and installation activities,

ensuring adequate resources are available, and

interfacing with quality assurance personnel on quality matters Project Procurement Manager The BLN Project Procurement Manager reports to the BLN Project Director and is responsible for:

supervision of supply chain personnel,

approving procurement documents, prior to issue,

communications and transactions between the project and suppliers; and

supplier commercial contract review.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 16 of 73

Title:

Bellefonte Project - Quality Assurance Plan Project Training Manager The Training Manager reports to the BLN Project Director and is responsible for:

Ensuring that the Training Plans meet the training requirements of the Project;

Ensuring that necessary resources are identified, planned for, and effectively applied;

Leading, organizing, and verifying the training and work activities of the training department;

Ensuring that the BLN Training Program follows and meets the requirements set out by the Contract with ND and the BLN Quality Assurance Plan;

Approving plans, work instructions, and training packages;

Ensuring Instructors are qualified in accordance with the training and procedures specified in this Plan;

Monitoring training facilities and support infrastructure, and reporting inadequacies to the BLN Performance Improvement Director;

Ensuring Trainees are qualified as required by the Project;

Ensuring that the BLN Training Coordinator maintains all training records accurately, and to an auditable standard;

Arranging self-assessments and internal audits to ensure procedures and best practices are followed; and

Obtaining feedback from the field (through OE reviews by Training Supervisors) and ensuring they are incorporated into the training program (continuous improvement process).

Project Onboarding Training Manager The Onboarding Training Manager reports to the BLN Training Manager, and is responsible for the following:

For the creation and maintenance of all training records in a learning management system;

For the interfacing with, and population of information into the NDs Operators learning management system (LMS);

To ensure that personnel assigned to perform engineering and support activities are trained, and qualified to perform their assigned tasks effectively.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 17 of 73

Title:

Bellefonte Project - Quality Assurance Plan 2

Quality Assurance Program SNC-Lavalin Nuclear Inc. will have overall responsibility for Project Quality Assurance for the Bellefonte Project and will comply with SNC-Lavalin Nuclear Inc. Quality Assurance Manual 2206-01-00-QM-0001.

SNC-Lavalins Nuclear Quality Assurance Program complies with applicable clauses from the following national and international standards:

ASME Boiler and Pressure Vessel Code,Section III, Division 1;

ASME NQA-1:2017, Part 1 Requirements for Quality Assurance Processes for Nuclear Facilities;

10 CFR Part 50 Appendix B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants.

SNC-Lavalin Nuclear Inc. will subcontract certain activities defined in the Procurement and Subcontract Management plan to qualified supplies for the activities they are subcontracted to perform. SLN shall accomplish oversight quality assurance for subcontracted activities in accordance with clause 0, Control of Purchased Items and Services.

The quality assurance program and supporting procedures (if applicable) will be identified and described in the following clauses. Throughout the life of the project procedures may be revised. These procedures may be SLN corporate procedures, SLN project specific procedures or supplier procedures for meeting Code and contract requirements. If this occurs, the SLN Quality Assurance Manager shall review these changes to ensure the change does not affect any commitment made in this Quality Assurance Plan. This is accomplished by the following procedures;

2206-01-20-OP-0001, Quality Assurance Document Control

2206-01-40-OP-0010, Evaluation of Supplier Quality Program Manuals Where a quality requirement is being met by a subcontractor, the applicable clause will describe the requirements that must be met to achieve project quality.

Subcontractors will comply with their Quality Assurance program accepted by SLN in addition to the additional project quality requirements included in this SLN Quality Assurance Plan (QAP) Subcontractors will demonstrate compliance to their Quality Assurance program and the applicable requirements of the SLN Quality Plan during the SLN supplier qualification maintenance process. This may be through audit or performance monitoring.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 18 of 73

Title:

Bellefonte Project - Quality Assurance Plan 2.1 Personnel Indoctrination and Training In addition to the mandatory Indoctrination and Training on the SLN Quality Assurance Program, The BLN Project team shall be indoctrinated in this QAP. Project personnel shall meet the indoctrination and training requirements of the Quality Assurance Program that controls the activities.

Project personnel performing or otherwise verifying activities affecting quality shall be competent on the basis of appropriate education, training, skills, experience and written examination. They will be provided with the appropriate indoctrination and training as necessary to assure suitable proficiency is achieved and maintained.

Personnel shall receive indoctrination and training prior to performing activities under this PQP when they change areas of responsibility and when this PQP and/or referenced procedures are revised. Training records shall be maintained for BLN Project personnel.

Indoctrination and training of personnel shall be carried out in accordance with SLN Operating Procedure 2206-03-10-OP-0001, Personnel Indoctrination and Training, as related to their job function. Supplier / Constructor personnel performing activities controlled directly by SLN Quality Manual shall be indoctrinated and trained to the SLN Quality Requirements.

Project specific training and qualification requirements shall be identified in the BLN Project Training Plan.

For organizations providing sub-contract services, any special qualifications or training requirements for their personnel working on the project, shall be specified in the subcontract agreements. All subcontract personnel shall be qualified for the work they are carrying out prior to performing any activity for which qualification is required by the project organization performing the work. In addition, subcontract personnel may be required to comply with the training requirements identified in the BLN Project Training Plan. All other non-quality related training shall be defined and described in the Project Training Plan.

Personnel Qualification All personnel shall be qualified for the work they are performing prior to performing any activity for which qualification is required by the project organization performing the work. Personnel qualification records shall be reviewed and verified by SLN during qualification of the supplier or during project surveillance of that activity.

Personnel qualifications will be recorded, maintained, and stored in accordance with the following SLN Procedures:

2206-01-40-OP-0003, QA Audit Personnel - Qualification Requirements;

2206-01-40-OP-0012, Inspection Personnel - Qualification Requirements;

2206-03-10-OP-0001, Personnel Indoctrination and Training;

2206-03-30-OP-0002, Engineering Qualifications Management;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 19 of 73

Title:

Bellefonte Project - Quality Assurance Plan SLN will audit and accept QA Programs of qualified Suppliers / Constructors. Personnel qualifications will be recorded, maintained and stored in accordance with procedural requirements. Personnel requiring qualification and certification include:

Test Personnel;

Receiving Personnel;

Inspection Personnel;

Source Surveillance Personnel;

Non-destructive Examination Personnel;

Audit Personnel;

Engineering Personnel performing American Society of Mechanical Engineers (ASME)

Code Certification activities;

Welders and Trade Personnel.

Personnel performing visual inspections required by the ASME Boiler and Pressure Vessel Code shall be qualified and certified according to ASME Code requirements.

Qualification of Engineering Personnel Personnel performing engineering work shall be qualified in accordance with SLN Operating Procedure 2206-03-10-OP-0002, Engineering Qualifications Management.

The Engineering Manager shall ensure Design Engineers involved in evaluating changes to final design have the demonstrated competence in the specific design area of interest and have an adequate understanding of the requirements and intent of the original design.

In addition, if there are project specific qualification requirements, the Engineering Manager shall ensure those requirements are incorporated into the Engineering Plan, and ensure personnel are qualified before assigning them to these specific roles.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 20 of 73

Title:

Bellefonte Project - Quality Assurance Plan 3

Design Control 3.1 Control of Design and Interfaces SLN has overall responsibility for engineering activities and shall directly perform design activities and provide support during construction and Start Up. Engineering activity shall be subcontracted to qualified suppliers as required.

The Engineering Manager has overall responsibility for design activity and control of design change ensuring that all designs/design changes on the BLN Project are defined, controlled, and verified. The Design Inputs shall be correctly translated into specifications, drawings, procedures and instructions. Design adequacy shall be verified by individuals other than those who designed the item.

Design changes shall be governed by control measures commensurate with those applied to the original design. The governing process is described under section 3.4.4, Design Change Control.

Design interfaces shall be identified and controlled. In the course of the design development and control, SNC-Lavalin shall interface with suppliers, the plant Operator and ND at various steps. Deviations to the Interface Requirements will be documented in the Scope of Work or applicable Master EC Package.

Qualification of engineering personnel who perform verification activities shall be qualified in accordance with Operating Procedure 2206-03-10-OP-0002 Engineering Qualifications Management.

The Engineering Plan identifies the organizations, controls, and responsibilities among participating organizations for the preparation, review, approval, issue, distribution, and revision of design documents.

The Engineering Manager is responsible for identification and control of design interfaces and for coordination of the design efforts among the project organizations.

The Document Control Lead shall ensure information transmitted across interfaces shall identify the status of the design information or document provided. Where it is necessary to initially transmit design information orally or by other informal means, the transmittal shall be confirmed promptly by a formal submission.

Engineering interface control shall be described, as appropriate, in the following documents:

  • The Engineering Plan for the project;
  • The supporting Design Plan for the particular scope of work;
  • The Design Verification Plan.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 21 of 73

Title:

Bellefonte Project - Quality Assurance Plan 3.2 ND Enterprises Asset Management The Enterprise Content Manager system (ECM) will remain as a repository for Engineering Design Changes (EDCs) and shall be used to control modification progression through SLN.

Relevant ECM fields will be populated as needed to progress work and maintain configuration management. Engineering will be required to populate the relevant ECM fields at the end of the following modification phases:

At the start of Scoping to register Master EDCs.

At the end of Modification Planning to populate Master EDCs, and populate the Master Equipment List (MEL).

At the end of Design Completion and prior to Available for Service to incorporate all field, and non-intent changes.

Prior to Closeout to launch the AEL, and populate closeout related panels.

A scanned version of the approved Master EDC Binder and/or Design Package shall be uploaded to ECM. When the opportunity arises to populate ECM, the EDC packages shall be attached to the Reference Document List of the relevant Master or Design EDC.

Approval of the EDC resides with the scanned copies of the packages in ECM.

3.3 Design Planning A Design Interface Agreement (DIA) will be put in place between ND and SNC-Lavalin Nuclear Inc. The DIA defines and documents the responsibilities of ND and SNC-Lavalin Nuclear Inc. in sufficient detail to cover the preparation, review and approval, issuance, distribution and revision of documents across design interfaces.

The overall responsibility for engineering resides with SLN.

The Engineering Manager has overall responsibility for design/design change and shall ensure all designs/design changes on the BLN Project are defined, controlled, and verified.

The Design Inputs shall be correctly translated into specifications, drawings, procedures and instructions. Design adequacy shall be verified by individuals other than those who designed the item.

Engineering activities shall consist of a set of Engineering Design Changes (EDCs) documented in Modification Packages. The EDCs will provide the necessary authorization and directions to perform Plant modifications.

The Engineering Manager is responsible for preparation of an Engineering Plan and supporting Design Plans with the necessary level of detail to permit the design process to be carried out in a correct manner and to permit verification the design meets requirements. The Engineering Plan and supporting Design Plans shall include:

  • Work Package Identification and Description;
  • Work to be Sub-contracted;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 22 of 73

Title:

Bellefonte Project - Quality Assurance Plan

  • Interfaces and Division of Responsibility;
  • Quality Assurance Program Requirements;
  • Regulatory and Code Requirements;
  • Design Inputs;
  • Human Factors Engineering;
  • Design Requirements;
  • Assumptions and Validation of Assumptions;
  • Design Processes and Tools;
  • Design Tasks and Activities;
  • Design Outputs and Deliverables;
  • System Classification;
  • Signing Protocol;
  • Design Verification;
  • Procurement Considerations;
  • Design Change Control;
  • Tasks and Deliverables Status;
  • Assignment of Responsibility.

The Engineering Plan and supporting Design Plans shall be reviewed and approved in accordance with operating procedure XXX, Bellefonte Design Change Procedure. As changes occur during the design process, the Engineering Manager shall ensure Engineering Plan and supporting Design Plans are updated and maintained. The Engineering Plan and supporting Design Plans shall be prepared to fully reflect the requirements of the Project Quality Plan.

Modification Packages shall be submitted for review and acceptance, through the Engineering Manager. Following acceptance by SLN, the Modification Packages will be issued to the subcontractor in accordance with clause 6, Document Control.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 23 of 73

Title:

Bellefonte Project - Quality Assurance Plan 3.4 Engineering Design Changes (EDCs)

Design inputs The Engineering Manager shall ensure design inputs are identified and documented, and their selection reviewed for adequacy and approved. Design Inputs shall be accepted in accordance with XXX, Bellefonte Design Change Procedure.

Design inputs shall contain sufficient detail necessary to permit the design activities to be carried out in the correct manner and provide a reference basis for decision making, performance of design verification and evaluation of design changes.

Any changes to design input during the design process, shall be subject to acceptance in accordance with the original requirements.

Design Process The Engineering Manager shall ensure requirements of the design specification have been correctly translated into technical specifications, drawings, procedures, and instructions, throughout the design process.

The design methods, material, parts, equipment and processes that are essential to the function of the item shall be selected and reviewed for suitability of application through the preparation, review, and approval of the Engineering Plan. Applicable information derived from experience, as set forth in reports or other documentation shall be made available to appropriate design personnel.

The Engineering Manager shall ensure the final design:

Is relatable to the design input documentation in sufficient detail to permit design verification;

Specifies required inspection and tests and includes or references appropriate acceptance criteria;

Identifies assemblies and/or components that are part of the item being designed. When such an assembly or component part is a commercial grade item, the characteristics of the item to be verified for acceptance and the acceptance criteria for those characteristics shall be documented.

The Master Engineering Change (MEC) or Engineering Design Change (EDC) development shall follow the ND Enterprise Asset Management process, and applicable in the ND governance. In addition, the SLN design process shall comply with all required procedures related to the engineering design and configuration management process.

The Engineering Manager shall ensure design analysis is planned, controlled, and documented in accordance with the Design Plan. The design analysis document shall be legible and in a form suitable for reproduction, filing, and retrieval. In addition, design analysis shall be sufficiently detailed as to purpose, method, assumptions, design input, references, and units such that a person technically qualified in the subject can review and understand the analysis and verify the adequacy of the results without recourse to the originator of the design.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 24 of 73

Title:

Bellefonte Project - Quality Assurance Plan Design calculation shall be identified by document number and shall include, as a minimum, the following:

Subject - including structure, system or component, to which the calculation applies;

Preparer and date;

Reviewer and date;

Approver and date.

The Engineering Manager shall ensure pre-verified computer programs used in the design process are validated prior to softwares first use. Validation shall be in accordance with SLN Operating Procedure 2206-07-50-OP-0003, Design Software Verification and Validation.

The Engineering Manager shall ensure design analysis documentation includes:

The objective of the analysis;

Design inputs and their sources;

Results of literature searches or other applicable background data, e.g. Operating Experience (OE);

Assumptions and indication of those assumptions that must be validated as the design proceeds;

Identification of any computer program, including identification of the computer type, computer program name and revision, inputs, outputs, evidence or reference to computer program verification, and the bases (or reference thereto) supporting application of the computer program to the specific physical problem.

Design Verification Design outputs shall be provided in a format suitable for verification against design inputs and shall be approved prior to issue as identified in the Design Verification Plan and Design Plan.

The design output documentation shall be adequate to support the facility design, construction, and operation. Design output shall:

Be uniquely identified;

Meet the design input requirements;

Specify the quality assurance requirements to be applied to the structure, system, or components and / or services;

Specify jurisdictional requirements, codes, standards, classifications and other criteria;

Provide appropriate information and traceability for subsequent phases including:

purchasing, construction, installation, commissioning, operation, decommissioning, or software development;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 25 of 73

Title:

Bellefonte Project - Quality Assurance Plan

Contain or reference item or service acceptance criteria;

Specify the characteristics of the item or service that are essential for its safe and proper use.

The Design Engineer shall determine the Quality Assurance Program Category and shall perform an empirical and functional evaluation.

Deficiencies found in Design Output documents during subsequent phases of purchasing, fabrication, installation, construction, commissioning, operations, decommissioning or software development, shall be handled in accordance with SLN Quality Assurance Manual, Section 15, Control of Nonconforming Items and Services.

When deficiencies are found by organizations other than SLN, the deficiencies shall be reported to SLN in accordance with the organizations quality assurance program that found the deficiency. SLN shall record, review and evaluate these deficiencies in accordance with SLN Quality Assurance Program. The results of the evaluation shall be communicated to relevant organizations in accordance with the following sections of the SLN Quality Assurance Manual:

Section 15, Control of Nonconforming Items and Services;

Section 16, Corrective Action;

Section 3.8, Design Change Control.

The Engineering Manager shall ensure at appropriate stages in the design process, as detailed in the Design Verification Plan. The Design Verification Plan shall be issued in a timely manner to ensure the design output satisfies the design input requirements. The results of the design verification shall be documented based upon the verification method including identification of the verifier.

Verification shall be performed by competent individual(s) or group(s) independent of those who performed the original design.

The Engineering Manager shall ensure design verification is performed prior to releasing the design for procurement, fabrication, installation, or for use by another design organization. In addition, design verification must be completed prior to the structure, system, or component, is required to perform its intended function.

If the design is revised to resolve verification findings, the revised design shall be verified prior to release for use.

Where changes to previously verified designs have been made, design verification shall be required for the changes. The verification shall include an evaluation of the effects of the changes on the overall design and on any design analysis upon which the design in based.

The Design Engineer shall ensure any other documents affected by the design change are revised and controlled.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 26 of 73

Title:

Bellefonte Project - Quality Assurance Plan The nature and extent of design verification shall be dependent upon:

Importance or impact on safety of the structure, system, or component;

Complexity of the design;

Degree of standardization;

The state of the art; and

Similarity to previously proven designs.

Verification shall employ one or more of the following methods;

Design Review;

Alternate Calculations; or

Qualification Testing.

Design reviews shall provide assurance the final design is correct and satisfactory by addressing the following:

Were the design inputs correctly selected?

Are assumptions necessary to perform the design activity adequately described and reasonable? Where necessary, are the assumptions identified for subsequent re-verification when the detailed design activities are completed? Were assumptions validated?

Were appropriate design methods and computer programs used?

Were the design inputs correctly incorporated into the design?

Is the design output reasonable compared to design input?

Are the necessary design inputs and verification requirements for interfacing organizations specified in the design documents or in supporting procedures or instructions?

Have suitable materials, parts, processes, and inspection and testing criteria been specified?

Alternate calculations shall use alternate methods to verify correctness of the original calculation or analysis. Alternate calculations shall be performed by qualified individuals as identified in the Design Verification Plan. The appropriateness of assumptions; input data used; and the computer program, its associated computer hardware and system software, or other calculation method used shall also be reviewed.

As documented in the Design Verification Plan, qualification testing shall be performed by a qualified sub-contractor controlled in accordance with this Project Quality Plan.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 27 of 73

Title:

Bellefonte Project - Quality Assurance Plan The test procedure(s) shall clearly define the test configuration, pre-requisites, methods, equipment, and acceptance criteria. The test procedure(s) shall be reviewed and accepted by the assigned verifier as documented in the Design Verification Plan.

Qualification testing shall demonstrate the adequacy of performance under conditions that simulate the most adverse conditions. Operating modes and environmental conditions in which the item must perform satisfactory shall be considered in determining the most adverse conditions. Where the qualification test is intended to verify only specific design features, the other features in the design shall be verified by other methods.

When tests are performed on models, scaling laws shall be established and verified. The results of model test work shall be subject to error analysis, prior to use in the final design.

All testing procedure(s) and complete documentation shall be included in the Qualification Test Report. This Report shall be submitted to the assigned verifier for review, and to the Engineering Manager for acceptance.

If qualification testing indicates modifications to the item are necessary to obtain acceptable performance, the Engineering Manager shall ensure the design output documents are revised, the item modified and retested.

The test procedure and test reports shall be retained in accordance with Section 17 of SLN Quality Manual.

Design Change Control Design Change Control applies to ND accepted EDC packages. The Engineering Manager shall ensure non-intent design changes to final designs and field changes are justified, evaluated and subject to design control measures commensurate with those applied to the original design. Where the original personnel are not available, the Engineering Manager shall either assign qualified personnel / consult with ND to identify a new responsible organization for ND activities, and ensure the Engineering Plan, Design Plans and Design Verification Plan are updated.

The Engineering Manager shall ensure the evaluation include the effects of those changes on the constituent parts, delivered items, overall design, and on any design analysis upon which the design is based. The evaluation shall include facility configurations that occur during operations, maintenance, test, surveillance, and inspection activities.

Non-intent design changes initiated from Field Initiated Changes (FICs) shall be approved by the Design Engineer. For all intent design changes, the EC Package shall be revised and approved in the same manner as the original including ND acceptance.

Commercial Grade Dedication SNC-Lavalin Nuclear shall ensure that controls are established for the Commercial Grade Dedication of purchased items as identified in the Design Specification.SLN shall ensure that all safety-related items are purchased as Basic Components, from suppliers whose quality program has been subject to audit by SLN and through examination of objective evidence has been evaluated to meet applicable requirements of 10 CFR Part 50 Appendix B and ASME NQA-1.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 28 of 73

Title:

Bellefonte Project - Quality Assurance Plan SNC-Lavalin Nuclear shall ensure that the Technical Determinations and records related to Commercial Grade Dedication are appropriately documented and included in the items History Docket or History File.

Human Factors Engineering The Human Factors Engineering Program (HFE), 152918-0000-31100-40HF-000x, provides requirements and details on the HF program for the BLN project. HFE plan and HFE preliminary report shall be prepared, during engineering phase, and the HFE report shall be finalized during the commissioning stage The Human Factor Engineering Program Plan shall be provided to SLN for acceptance during the engineering phase.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 29 of 73

Title:

Bellefonte Project - Quality Assurance Plan 4

Procurement Document Control 4.1 General Requirements The procurement of Engineered Items and Services shall be undertaken by SLN and shall comply with SLNs Quality Assurance Program and the 152918-0000-00000-50IM-0001, Materials/Procurement Management Plan, which will include:

Organizational responsibilities;

Procurement methods;

Items and services to be procured;

Procurement schedule at a summary level.

The Discipline Engineer shall ensure that applicable design basis and other requirements necessary to assure adequate quality shall be included or referenced in documents for procurement of items and services.

For the purpose of this section, Procurement Documentation includes Requests for Quote, Request for Proposal, or Request for Tender, generically referred to as (RFX), and the Purchase Order (PO).

The design and quality requirements for the procured items and services will be defined, documented and provided in accordance with SLNs procedure 2206-07-30-OP-0007, Engineering Quotation Request. It shall comply with the requirements of Section 5.0.

SLN shall perform oversight by means of quality surveillance at the qualified suppliers premises or at site as applicable during the fabrication and manufacturing of Items prior to release for shipment and for Construction Services in accordance with the following SLN operating procedures:

2206-06-40-OP-0001, Preparation of Surveillance Plans;

2206-06-40-OP-0002, Performance of Quality Surveillance.

Applicable design basis and other requirements necessary to assure adequate quality of procured items and services shall be included or referenced in the procurement documents.

According to SLN procedure 2206-06-40-0P-0001 Quality Surveillance Plans are prepared for each Purchase Order based on the following:

Supplier's Inspection and Test Plan (ITP);

Evaluation of critical quality characteristics of the item;

Jurisdictional and Code requirements, as applicable;

Supplier's previous performance in the administration of quality programs and in the supply of items.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 30 of 73

Title:

Bellefonte Project - Quality Assurance Plan A Quality Surveillance Record shall be prepared by SLN to document surveillance activities performed. For oversight on other procurement activities not covered by ITPs, a graded approach will be used by SLN and a report using Controlled Form 2206-01-40-CF-0015, Surveillance Report will be filed in Document Control. Supplier Corrective Action Requests shall be issued by SLN for non-conformances found during oversight; All nuclear pressure boundary items and related services will be procured in compliance with the requirements of NCA-4000.

Non pressure boundary items and related services will be procured in compliance with the applicable quality program category requirements determined during the design phase.

Subparts of an assembly or related service may be evaluated by the Design Engineer for the appropriate quality level.

The design and quality requirements for the BLN procured items and services will be defined, documented and provided in accordance with SLNs procedure 2206-07-30-OP-0007, Engineering Quotation Request.

All approved suppliers to SNC-Lavalin shall be on the SLNs or NDs Approved Supplier List (ASL). Each supplier to the SNC-Lavalin shall control its suppliers in accordance with the respective suppliers Quality Assurance Program.

Identification and control of counterfeit, fraudulent and sub-standard materials or items shall be controlled in accordance with the Quality Assurance Program of the organization controlling the purchased items.

The following procedures shall apply for procurement activities undertaken by SLN:

2206-07-30-OP-0007, Engineering Quotation Request;

2206-06-00-OP-0001, Purchasing Strategy - Project and Customers;

2206-06-30-OP-0006, Preparation and Award of Purchase Orders;

2206-01-20-OP-0001, Quality Assurance Document Control;

2206-06-10-OP-0004, Quality Assurance Evaluation of Tenders; Procurement Planning Procurement planning shall start at the early stage of the project. The project procurement planning shall align with engineering planning to ensure that necessary engineering documents are planned, approved and ready when they are required for procurement activities.

The Materials/Procurement Management Plan, 152918-0000-00000-50IM-00xx describes the strategy and procurement processes used by the SNC-Lavalin for the BLN project during the design phase. The plan shall include also requirements for storage, security, screening, maintenance and control of shelf life items.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 31 of 73

Title:

Bellefonte Project - Quality Assurance Plan All items procured by SLN shall be delivered to SNC-Lavalin authorized warehouse. 2206 30-0P-0009, Receiving Inspection procedure defines SNC-Lavalin's process and requirements for performing the receiving and receiving inspection of supplied items for the BLN Project.

This procedure applies to all items delivered by SNC to SNC-Lavalin Warehouses or designated receiving areas for the BLN Project.

4.2 Content of Procurement Documents General Requirements The Buyer shall ensure that procurement documents provided to the supplier adequately describes the item or service to be purchased, including as a minimum, the following:

Technical requirements as specified in the Engineering Quotation Package (EQP) or Purchase Requisition

Quality Assurance Program requirements as specified in the Engineering Quotation Package (EQP) or Purchase Requisition

Commercial Requirements, and

Terms and Conditions (reviewed and accepted by ND).

The Project Director shall make available the contract information for procurement, engineering and quality assurance activities.

During the tendering process, the technical, quality assurance and commercial requirements will be communicated to a prospective supplier.

At Contract award, the Purchase Order will communicate the technical, quality assurance and commercial requirements to the selected supplier.

The Procurement Manager shall ensure that any changes affecting commercial, technical, or quality requirements are subject to the same degree of control as the original documents.

Scope of Work The Procurement Manager shall ensure that the Request for Quote includes a statement of the scope of work to be performed by the supplier.

Technical Requirements Engineering personnel shall ensure that Engineering Quotation Package or Purchase Requisition includes appropriate technical requirements. These requirements shall be documented and specified in an Engineering Quotation Package, as appropriate by reference to specific drawings, specifications, codes, standards, regulations, procedures, instructions, including revisions thereto that describe the items or services to be provided. The documented technical requirements shall include, as appropriate:

technical performance requirements,

codes, standards, and specifications,

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 32 of 73

Title:

Bellefonte Project - Quality Assurance Plan

jurisdictional and/or regulatory requirements,

inspection, test, and acceptance requirements, including any special instructions,

delivery requirements,

documentation submittal requirements and the timing of submittals and

provision for packaging, working, handling, storage and shipping.

Quality Assurance Program Requirements The Buyer shall ensure that purchasing documentation includes appropriate quality assurance program requirements including:

quality assurance program certification requirements

ASME Code Edition, addenda, and class of construction

requirements for acceptance of item or service, procedures, processes, and equipment

requirements for qualification of personnel

inspection, test, and acceptance requirements, including any special instructions

provisions for extending quality assurance requirements to sub-suppliers Right of Access The Request for Quote and the Purchase Order shall ensure that purchasing documentation includes right of access to the Suppliers and Sub-Suppliers places of work, facilities, and records for surveillance, inspection, or audit by the BLN Project, the Owner, or eithers authorized or designated representatives, and if applicable, the ANII.

Documentation Requirements The Request for Quote or Purchase Order shall identify the documentation required to be submitted for information, review, or acceptance, by SLN or the Owner and the timing of submittals. If the Supplier is required to maintain records, the retention times and disposition requirements shall be included in the Request for Quote or Purchase Order.

Non-conformances The Purchase Order shall require the supplier to report item or service non-conformances and for SLNs acceptance or rejection of the suppliers recommended disposition.

Suppliers Non-conformances (NCRs) for use as is or repair/rework and Deviation Disposition Request (DDRs) applicable to manufacturing of items are submitted to SLN and processed as per 2206-01-20-OP-0003 Document Control Routines.

Spare and Replacement Parts The Buyer shall ensure that the Purchase Order specifies requirements for spare and replacement parts or assemblies and the related technical and quality assurance requirements for ordering these parts or assemblies.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 33 of 73

Title:

Bellefonte Project - Quality Assurance Plan 4.3 Procurement Document Review Procurement Document review shall ensure that the content of Procurement documentation complies with the requirements of Clause 4.2 above.

The Project Procurement Manager shall review the adequacy of specified purchasing requirements contained in Procurement documents, and revisions thereto, prior to issue of Request for Quote or award of Purchase Order. This ensures that Procurement documents, when transmitted, include provisions to assure that items or services shall meet specified requirements. Evidence of this review shall be documented by the Project Procurement Managers signing the Request for Quote or Purchase Order.

Technical, quality assurance program, or commercial changes required during the Tendering Process shall be evaluated prior to issue of an Addenda to the RFX.

Bid Evaluations shall be performed in accordance with 2206-06-10-0P-0004, Quality Assurance Review of Tenders and 2206-07-30-0P-0010, Technical Tender Evaluation.

Technical or quality assurance program changes made as the result of bid evaluations or negotiations shall be evaluated prior to being incorporated into the Purchase Order and supporting documents (EQP, data sheets, drawings, etc.), prior to Purchase Order award.

4.4 Procurement Document Changes The BLN Procurement Manager shall ensure that any changes affecting commercial, technical, or quality assurance program requirements are subject to the same degree of control as the original documents.

Applicable Operating Procedures are as follows:

2206-01-20-OP-0001 Quality Assurance Document Control

2206-06-00-OP-0001 Purchasing Strategy - Projects and Customers

2206-06-30-OP-0006 Preparation and Award of Purchase Orders

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 34 of 73

Title:

Bellefonte Project - Quality Assurance Plan 5

Instructions, Procedures and Drawings All activities affecting quality and services shall be prescribed by and performed in accordance with documented instructions, procedures, or drawings that include or reference appropriate quantitative or qualitative acceptance criteria for determining that prescribed requirements have been satisfactorily accomplished.

Each activity shall be described to a level or detail commensurate with the complexity of the activity and the need to assure consistent and acceptable results. The need for, and level of detail in, written procedures or instructions shall be determined based upon complexity of the task, the significance of the item or activity, work environment, and worker proficiency and capability (education, training, and experience).

Documents, instructions, procedures, and drawings shall be made available at the point of use to SNC-Lavalin personnel and to the Customer or ANII as required.

The preparation, review, approval, revision, and issue of documents, instructions, procedures and drawings shall be in accordance with this QAP.

Applicable procedures are:

2206-01-20-OP-0001 Quality Assurance Document Control

2206-07-20-OP-0001 Preparation of Engineering Documents

2206-07-00-OP-0001 Drafting Procedure

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 35 of 73

Title:

Bellefonte Project - Quality Assurance Plan 6

Document Control 6.1 General Requirements The preparation, review, approval, revision, and issue of documents that specify quality requirements or prescribe activities that affect quality shall be controlled to assure that correct documents are utilized by personnel at the location where activities affecting quality are being performed. All such documents shall be reviewed for adequacy and approved for release by authorized personnel. All documents, software and analytical tools related to the implementation of the Quality Assurance Program shall be controlled.

Documents, including changes, shall be reviewed for adequacy and approved for release by authorized personnel and be distributed to and used at the location where the activity is performed.

SLNs qualified Supplier / Constructor shall meet requirements of their QA Programs Document Control requirements.

Quality Assurance Documentation The issue, distribution and retention of all project documentation shall be in accordance with 2206-01-20-OP-0003 Document Control Routines.

The preparation, review, approval, revision, issue and retention of Audit Plans, Audit Reports, Audit Checklists, completed Audit files and the Quality Assurance Report shall be controlled by the Director, Quality Assurance.

Engineering Documentation The issue and retention of project Engineering Documentation shall be in accordance with 2206-01-20-OP-0003 Document Control Routines.

Supplier Documentation Documentation identified as Supplier deliverables in a Purchase Order shall be formally submitted to the responsible SNC-Lavalin Nuclear Buyer or Expeditor.

The Buyer or Expeditor shall forward this documentation to Document Control for logging into PM+ or MyTRAK as applicable, followed by Vendor Internal Coordination Review which includes acceptance by Quality Assurance and Engineering.

When using MyTRAK, Suppliers shall continue using the PDMC Supplier portal to submit new or revised Supplier document/drawings and retrieve accepted or commented Supplier document/drawings.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 36 of 73

Title:

Bellefonte Project - Quality Assurance Plan 6.2 Document Identification and Preparation Quality Assurance documentation shall be identified in accordance with operating procedure 2206-01-20-OP-0001, Quality Assurance Document Control.

Engineering documentation shall be identified in accordance with operating procedure 2206-01-20-OP-0001 Quality Assurance Document Control. Operating procedure 2206-07-20-OP-0001 Preparation of Engineering Documents shall provide supplementary information on the preparation, review, and approval of Engineering documents.

All controlled documents shall be prepared using standard templates such as Controlled Forms and Template Forms as described in Operating Procedure 2206-01-20-OP-0001, Quality Assurance Document Control.

6.3 Document Changes Changes to documents shall be reviewed and approved by the same organization that performed the original review and approval, unless other qualified organizations are designated.

The reviewing organization shall have access to pertinent background data or information upon which to base their review and approval.

Revised documents shall be distributed to and used at the location where the activity is performed. Distribution shall be controlled as detailed in clause 6 above.

Applicable Operating Procedures are:

2206-01-20-OP-0001 Quality Assurance Document Control

2206-01-20-OP-0002 Control of Quality Records

2206-01-20-OP-0003 Document Control Routines

2206-01-20-OP-0004 Permanent Records History Docket / History File

2206-07-20-OP-0001 Preparation of Engineering Documents

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 37 of 73

Title:

Bellefonte Project - Quality Assurance Plan 7

Control of Purchased Items and Services 7.1 General Requirements Procurement activities shall be planned, documented and controlled to assure conformance with procurement documents. Such controls shall provide for the following as appropriate: supplier evaluation and selection, supplier qualification, evaluation of objective evidence of quality furnished by the supplier, source inspection, audit, and examination of items or services upon delivery or completion.

Additional requirements may be specified, depending on the quality assurance specifications or nature of the item or service provided. These additional requirements may include: quality surveillance, quality audits, and additional quality records.

The Project Procurement Manager, who reports to the Project Director, shall be responsible for all procurements activities related to the project. Procurement may be performed by SLN or subcontracted as defined in the Procurement and Subcontract Management Plan.

Procurement activities performed in accordance with 10CFR50 Appendix B, shall meet the requirements of 2206-01912-QM-0001 SNC-Lavalins Nuclear Quality Assurance Manual and the following supporting procedures; The following activities shall be undertaken by SLN:

Perform quality surveillance at suppliers premises during the fabrication and manufacturing of items prior to release for shipment in accordance with the following SLN operating procedures: 2206-06-40-OP-0001, Preparation of Quality Surveillance Plans and 2206-06-40-OP-0002, Performance of Quality Surveillance; The extent of quality surveillance varies with the scope of contracted services and location of the services;

Perform receiving inspection of Engineered Items and services upon receiving of the items at designated deliver location in accordance with operating procedure 2206 30-OP-0009, Receiving Inspection.

The following Operating Procedures shall be used to control items and services purchased by SLN:

2206-01-40-OP-0004, Performance of Audits;

2206-06-30-OP-0003, Evaluation and Selection of Suppliers;

2206-01-40-OP-0010, Evaluation of Supplier Quality Program Manuals;

2206-06-40-OP-0001, Preparation of Surveillance Plans;

2206-06-10-OP-0004, Quality Assurance Evaluation of Tenders;

2206-06-30-OP-0006, Preparation and Award of Purchase Orders;

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 38 of 73

Title:

Bellefonte Project - Quality Assurance Plan

2206-07-20-OP-0001, Preparation of Engineering Documents;

2206-01-20-OP-0003, Document Control Routines;

2206-01-20-OP-0004, Permanent Records History Docket / History File;

2206-06-40-OP-0002, Performance of Quality Surveillance;

2206-06-70-OP-0002, Supplier Performance Evaluation;

2206-01-30-OP-0002, Control of Nonconforming Items and Services.

The requirements for execution of purchasing activities are specified in the Project Materials/ Procurement Management Plan, 152918-0000-0000-50IM-000.

7.2 Procurement Planning Overall Procurement (procurement) planning process shall include:

requirements for preparation, revision, review, approval, and issue of procurement documents

evaluation and selection of suppliers

bid evaluation and award

supplier control

verification of purchased items or services which may include: source surveillance, surveillance, inspection, test, or audit

control of supplier non-conformances and corrective actions

release of items

acceptance of items or services

quality assurance records The procurement requirements for a project shall be specified in the Project Execution Plan (PEP) or Project Management Plan.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 39 of 73

Title:

Bellefonte Project - Quality Assurance Plan The Project Execution Plan (PEP) shall be prepared by the Project Manager in accordance with operating procedure 2206-04-00-OP-0001, Project Management.

Depending on the complexity and extent of supply-chain activities, the Director, Procurement may elect to supplement the Project Execution Plan (PEP) with a specific Project Procurement Plan (PPP). In either case, the Project Execution Plan (PEP) or Project Procurement Plan (PPP) shall identify long lead items or major purchases listed in the Contract between SNC-Lavalin Nuclear and the Customer. It shall also identify any customer specific procurement requirements over and above the requirements of this Quality Assurance Manual.

Procurement cannot proceed until the Project Execution Plan (PEP) is issued.

Supply Chain activities shall be initiated by the receipt of either an Engineering Quotation Package (EQP) or a Purchase Requisition. The preparation of these documents is controlled in accordance with Section 4, Procurement Document Control.

When procurement of items or services is undertaken by SNC-Lavalin, this activity shall be performed in accordance with 2206-06-00-OP-0001, Purchasing Strategy-Projects and Customers. The design and quality requirements for the procured items and services shall be defined, documented and provided as input to the procurement process.

Procured materials/items are controlled and verified by performing the following activities:

Surveillance activities at suppliers are performed in accordance with 2206-06-40-0P-0002 Performance of Quality Surveillance.

Receiving inspection is performed as per the procedure 2206-01-30-0P-0009 Receiving Inspection.

Quality Surveillance applies to nuclear and non-nuclear items and services for nuclear power plants facilities purchased from Suppliers.

2206-06-40-0P-0002 Performance of Quality Surveillance applies to the following scope:

For the performance of inspection activities based on the Inspection and Test Plan(s) submitted by the supplier and accepted by SNC-Lavalin Nuclear;

For the performance of verification activities by SNC-Lavalin Nuclear to ensure procedural compliance by a supplier (for any applicable nuclear life cycle activity) while executing work to their QA Program.

The extent of quality surveillance varies with the scope of contracted services and location of the services. Applicable procedures are 2206-01-40-OP-0009 Evaluation of Supplier NDE Test and 2206-01-40-OP-0008 Evaluation of Inspection and Test Plans.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 40 of 73

Title:

Bellefonte Project - Quality Assurance Plan The Quality Assurance Specialist shall meet the following mandatory requirements when preparing the Quality Surveillance Plan and executing Quality Surveillance activities;

Procedures, instructions or drawings shall be reviewed to verify that they have been accepted by SLN. These documents shall include or reference appropriate quantitative or qualitative acceptance criteria for determining that prescribed requirements have been satisfactorily accomplished.

Personnel qualification records shall be reviewed and accepted prior to the individual performing any activity. Qualification records shall include; i)

NDE qualification records ii)

Welder qualification records iii)

Inspection personnel qualification records iv) Test personnel qualification records 7.3 Supplier Evaluation and Selection Supplier Evaluation for Bid Purpose Buyer initiates Bidders List from an Engineering Quotation Request (EQR) or Purchase Requisition to identify potential supplier(s) for the item or service to be purchased.

Quality Assurance Specialist validates the potential supplier(s) Quality Assurance Program consistent with the quality requirements as defined in the EQR or Purchase Requisition. For each potential supplier, this is accomplished by review of one or more of the following:

Status on the SLN Approved Suppliers List [based on an approved Controlled Form 2206-06-30-CF-0003, Supplier Qualification Record (SQR)]

Certificates of Authorization

Quality Program Manual ASME Code work shall be subcontracted to N Type Certificate Holders and Approved Suppliers for Design software only.

Results of the Supplier evaluation shall be documented on a Bidders List by the Quality Assurance Specialist as either Acceptable or Not Acceptable to submit a Tender Package to the potential Supplier. In addition, the potential Supplier shall be added to the Approved Suppliers List by the Quality Assurance Specialist as a minimum Qualified to Bid if not already listed.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 41 of 73

Title:

Bellefonte Project - Quality Assurance Plan Supplier Evaluation Prior to Purchase Order Award On receipt of a Bid, Commercial, Technical and Quality Assurance evaluations of the Bid are initiated by the Buyer by submitting copies of the Bid Documentation to a Discipline Engineer and a Quality Assurance Specialist for their respective evaluations.

The Buyer must check that the Supplier is listed on the Approved Suppliers List as Qualified to Award for the specified Quality Assurance Program and scope of supply.

If the Supplier is not listed on the Approved Suppliers List as Qualified to Award or the scope of work is different, the Buyer initiates the preparation or revision of supplier qualification records.

7.4 Bid Evaluation The Procurement Manager shall establish and implement processes for Bid evaluation and Award of Contract. These processes shall ensure that the basis for evaluations, selections and award of contract are documented.

The Bid evaluation shall consider technical, quality and commercial aspects Technical Evaluation is accomplished by a Tender Technical Evaluation (TTE) performed by a Discipline Engineer to ensure that the tender complies with the technical requirements of the procurement documents. This may include evaluation and disposition of exceptions and deviations from the procurement documents.

Quality Evaluation is accomplished by the Quality Assurance Evaluation (QAE) performed by a Quality Assurance Specialist to ensure that the tender complies with the quality requirements of the procurement documents. This may include evaluation and disposition of exceptions and deviations from the procurement documents.

Commercial Evaluation is accomplished by the Commercial Evaluation (CE) performed by the Buyer to ensure that the tender complies with the commercial requirements of the procurement documents. This may include evaluation and disposition of exceptions and deviations from the procurement documents.

In addition to the above mentioned requirements, where applicable to the type of procurement, and as identified in the Project Execution Plan (PEP) the following items shall also be considered:

suppliers key personnel

suppliers production capability

suppliers past performance The Buyer is responsible for coordinating evaluations and selection of the successful bid.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 42 of 73

Title:

Bellefonte Project - Quality Assurance Plan Bid evaluations shall confirm a suppliers ability:

accreditation, or capability of accreditation by relevant authorities or where applicable, acceptance of the supplier quality program by SNC audit, for the supply of product or service with applicable standards, codes, or jurisdictional requirements, and

the product or service offered meets appropriate commercial, quality and technical requirements including: safety, reliability and maintainability.

Prior to contract award, any exceptions or unacceptable conditions with respect to item or service requirements such as those listed in clause 4.2, or commercial considerations that are identified during bid evaluation shall either be resolved or the Supplier shall commit to resolve unacceptable conditions.

Contract award documentation shall identify any changes to the Tender documents commercial, technical or quality requirements as a result of bid evaluations or pre-contract negotiations and shall contain or reference all product requirements as listed above.

7.5 Qualification of Suppliers The Buyer initiates the supplier qualification process by communicating the requirements to qualify a supplier to the Quality Assurance Specialist using the 2206-06-30-CF-0003, Supplier Qualification Record.

The Suppler Qualification Record shall identify the required scope of qualification, items or services to be provided, and the associated quality assurance program requirements.

The Project Quality Assurance Specialist shall evaluate Suppliers capability to provide items or services in accordance with the requirements of the Supplier Qualification Record.

A Quality Assurance Specialist shall evaluate a Suppliers capability to provide items or services in accordance with the requirements of the Supplier Qualification Record.

Supplier audits shall be performed to assess the effectiveness of their Quality Assurance Program.

Once qualified, the Quality Assurance Specialist shall complete 2206-06-30-CF-0003 Supplier Qualification Record and add the supplier on the Approved Supplier List.

The Project Manager, Quality Assurance shall ensure the qualifications of supplier listed in the Approved Suppliers List and active for BLN project are reviewed, maintained and updated on a periodic basis.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 43 of 73

Title:

Bellefonte Project - Quality Assurance Plan 7.6 Control of Supplier Generated Documents The Project Procurement Manager shall implement appropriate controls to assure that the submittal and evaluation of supplier generated documents are accomplished. These controls shall provide for the receipt, processing, and recorded evaluation of the supplier generated documents. This evaluation shall consider the quality assurance, technical, and commercial requirements in support of acceptance of the item or service.

Documentation received by the Buyer from suppliers for acceptance shall be reviewed and accepted by qualified personnel. The Buyer shall initiate the review of supplier generated documents in accordance with operating procedure 2206-01-20-OP-0003, Document Control Routines.

7.7 Acceptance of Items or Services General Requirements The Project Quality Manager, as delegated by the SLN Director, Quality, shall ensure that purchased items or services conform to specified requirements. The type and extent of control applied to the supplier and purchased product shall be dependent upon the:

impact on safety,

complexity of the structure, system, component or service,

degree of standardization,

similarity to previously proven design,

reliability requirements,

performance or functional requirements,

applicable regulatory or jurisdictional requirements.

Quality Assurance Specialists shall perform item or service acceptance activities. The procurement documents shall specify that prior to the item or service being offered for acceptance, the Supplier shall verify that the item or service being furnished complies with the requirements of the procurement documents.

Acceptance activities may be performed at the suppliers premises or the customers premises.

The Quality Assurance Specialist shall review a Certified Material Test Report (CMTR) or Data Report to the ASME BPVC,Section II and Section III, and additional requirements of the ASME Code.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 44 of 73

Title:

Bellefonte Project - Quality Assurance Plan Methods of Acceptance SLN shall utilize one or more of the following methods to accept an item or service from a supplier:

a certificate of conformance provided by the supplier,

source verification,

receiving inspection, The preferred method of acceptance is source verification where receiving inspection is not practical. Certificates of Conformance may only be used for items manufactured and delivered for simple, standard catalogue items, best commercial items and spare parts.

Notwithstanding the above, a receiving inspection shall be performed by the Receiving Quality Control Inspector Quality Assurance Specialist.

Certificate of Conformance SLN shall implement appropriate processes to verify the validity of a suppliers certificates of conformance and the effectiveness of this process shall be evaluated during supplier audit, monitoring, or independent inspection and test of the material or equipment. Such audit, monitoring, or independent inspection activities shall be conducted by SLN at intervals commensurate with the suppliers past quality performance.

Source Verification The Quality Assurance Specialist shall perform source verification at intervals consistent with the importance and complexity of the item or service, and shall include monitoring, witnessing, or observing selected activities as per 2206-06-40-0P-0002 Performance of Quality Surveillance. The Surveillance Plan shall identify the suppliers inspections, examinations, or tests at predetermined points for which the Quality Assurance Specialist requires to inspect.

Surveillance Plans are not required to be submitted to the ANI.

Results of inspections, examinations, or tests shall be documented by the supplier and shall be reviewed by SLN prior to acceptance of the item or service. The Quality Assurance Specialist sign-off on the Surveillance Plan indicates his acceptance of the inspection activity.

Receiving Inspection The Operating Procedure 2206-06-30-0P-0001 Storage and Handling applies to items under the custody and control of SLN at a Storage Facility / Warehouse. Project-specific plans or procedures shall define how the material control system will be implemented to comply with technical document requirements, regulatory requirements and Codes and Standards requirements.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 45 of 73

Title:

Bellefonte Project - Quality Assurance Plan

[Note: 2206-06-30-0P-0001 Storage and Handling does not apply if the storage and handling of items is sub-contracted by a project to a qualified Supplier / Constructor in accordance with the Project Quality Plan. In such cases, the qualified Supplier /

Constructor shall implement their own Quality Assurance (QA) Program and SLN shall perform surveillance / oversight for the verification of their procedural compliance using 2206-06-40-0P-0002, Performance of Quality Surveillance].

2206-01-30-0P-0009 Receiving Inspection applies to all receiving inspection activities performed by SNC-Lavalin Nuclear and shall consider prior source verification.

Inspection Personnel performing receiving inspection activities will be qualified in accordance with 2206-01-40-0P-0012 Inspection Personnel - Qualification Requirements.

Receiving QC Inspector shall perform receiving inspection on purchased items to ensure conformance to procurement documents.

Items that conform to the specified requirements shall be identified as such (accepted) and either held in storage for later release or released and moved directly to their final location for subsequent processing or use.

Items that do not conform to specified requirements shall be identified as nonconforming and shall be segregated to prevent inadvertent processing or use.

Post Installation Testing When post installation testing is utilized, SLN shall establish post installation testing requirements, including required documentation to support product acceptance, with the product supplier Acceptance of Services Only SLN shall accept services by using one or more of the following methods:

technical verification of the data produced,

surveillance and/or audit of the activity, review of objective evidence for conformance to the procurement document requirements.

7.8 Control of Supplier Non-Conformance All NCRs generated by suppliers and dispositioned as Use as is or Repair shall be reviewed for acceptance by SLN. Following methods are recommended to be used for controlling supplier non-conformance:

evaluation of nonconforming items,

review of supplier submitted non-conformance reports including supplier recommended disposition (use-as-is or repair) and technical justification. Non-conformances to the procurement requirements or SLN approved documentation, which consist of one or more of the following, shall be submitted to SLN for approval of the recommended disposition:

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 46 of 73

Title:

Bellefonte Project - Quality Assurance Plan

deviations from technical or material requirements;

deviations from approved requirements for supplier documentation;

non-conformance which cannot be corrected by continuation of the original manufacturing process or by rework;

the item does not conform to the original requirements even though the item can be restored to a condition such that the capability of the item to function is unimpaired;

evaluation and disposition of the supplier recommendation;

verification of the implementation of the disposition;

maintenance of records of supplier submitted non-conformance.

Non-conformances to design requirements dispositioned as use-as-is, rework or repair shall be subject to design control measures commensurate with those applied to the original design. Required as-built records shall reflect the use-as-is or repair condition.

In all cases, disposition of a supplier non-conformance cannot negate the requirements of the ASME Code. SNC-Lavalin review and acceptance is required prior to performing any repair or re-examination activities.

If the repairs are likely to affect the results of examination, inspection or tests, or work previously completed, appropriate re-examination, re-inspection, and re-testing shall be performed in accordance with approved procedures.

The Supplier has responsibility to identify nonconforming items by legible marking, tagging, or other methods not detrimental to the item, either on the item or on the container, or the package containing the item.

7.9 Commercial Grade Items and Services The Commercial Grade Items and Services shall only be applied to non-pressure-boundary safety-related items.

Where SNC-Lavalins nuclear design utilized commercial grade items, SNC-Lavalin Nuclear performs the same as per 2206-01-50-OP-0002 Dedication of Commercial Grade Items.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 47 of 73

Title:

Bellefonte Project - Quality Assurance Plan 7.10 Purchase Order Administration The Project Procurement Manager shall establish and implement appropriate controls for the administration of contracts and purchase orders.

Any changes affecting commercial, technical, or quality requirements proposed either by SLN, the customer, or a supplier, shall be documented and approved in accordance with the original document.

The Project Procurement Manager shall track and record supplier performance and retain hardcopies of this information in the applicable supplier history file for future reference.

Electronic copies of this information may be stored in an electronic database.

7.11 Purchase Order Completion The Procurement Manager shall establish and implement a close-out process for termination of contract agreements following acceptance of items or service or for cause.

The procedure 2206-06-70-OP-0001, Purchase Order Completion applies.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 48 of 73

Title:

Bellefonte Project - Quality Assurance Plan 8

Identification and Control of Items 8.1 General Requirements Identification and control of items shall ensure that:

only correct and accepted items are used and installed identification is maintained on the item or in documents traceable to the item, or in a manner which ensures that identification is established and maintained.

The Project Quality Manager shall establish controls to assure that only correct and accepted items are used and installed.

8.2 Identification Methods Item Identification The Quality Assurance Specialist performing source surveillance and the Receiving QC Inspector shall identify items by tags, physical markings or documentation traceable to the item. Any marking applied to an item shall be clear, legible and not adversely affect the material, function or service of the item.

Records demonstrating unique identification of each item, or part thereof, shall be maintained as part of HD/HF (History Docket / History File). Where traceability is a requirement for purchased items, the procurement documents shall include requirements to control and record a unique identification of each item, or part thereof, and maintain records.

Physical Identification Physical identification shall be used to the maximum extent possible. Markings shall be clear and permanent and shall not adversely affect the material, function or service life of the item so identified.Where physical identification on the item is either impractical or insufficient, physical separation, procedural control, or other appropriate means shall be employed. In such cases, the item must be included in records traceable to the item.

Any physical identification or marking applied to the item, shall not be hidden or obliterated by surface treatment or coating unless other means of identification are provided in accordance with documented procedures.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 49 of 73

Title:

Bellefonte Project - Quality Assurance Plan 8.3 Specific Requirements Identification and Traceability of Items Quality Assurance Specialists shall ensure that identification and traceability requirements of applicable standards, codes, or specifications are applied as required to ensure traceability to heat, batch, lot, part number, serial number, specified inspection, test or other records as required by the EQR and PO.

Customer specified requirements for identification and traceability of items shall be documented in EQR and applicable technical specifications.

Limited Life Items Limited Life Items shall be handled in accordance with Storage and Handling Procedure which is to be written.

Maintaining Identification of Stored Items The BLN Project shall ensure that appropriate controls are implemented for maintaining item identification consistent with the planned duration and conditions of storage in accordance with the Material Control Plan, which is to be written.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 50 of 73

Title:

Bellefonte Project - Quality Assurance Plan 9

Control of Processes The scope of SLNs Certificate of Authorization requires fabrication and installation activities to be subcontracted to an appropriate ASME Certificate of Authorization holder.

The controls for special processes will be the responsibility of the qualified Supplier subcontracted to perform fabrication and installation.

BLN project shall review and accept Supplier procedures in accordance with this section for welding, heat treating, and non-destructive examination to ensure compliance with the ASME Code, 10 CFR Part 50 Appendix B, ASME NQA-1,and Customer specified requirements.

9.1 Process Control The Project Director shall ensure that the processes are controlled through the use of an Inspection and Test Plan (ITP) as applicable.

For all work subcontracted to qualified suppliers the Quality Assurance Specialist shall review and accept the suppliers Inspection and Test Plans as per the Operating Procedure 2206-01-40-OP-0008, Evaluation of Inspection and Test Plans.

Inspection and Test Plans shall include, but not limited to the following:

identify required Verification, Witness and Hold points,

the signature, initials, or stamp, and the date the activity was performed by the Quality

Assurance Specialist,

the signature, initials, or stamp, and the date the activity was performed by the Certificate Holders representative,

the signature, initials, or stamp, and the date on which those activities were witnessed by the Authorized Nuclear Inspector (ANI),

space for the signature, initials, or stamp, and the date the activities were witnessed by the Customer, as required,

document number and revision to which the process conforms,

space for reporting results of completion of specific operations,

document number and revision to which the examination and test is to be performed, and

space for recording results of examinations and tests.

The supplier is responsible to submit the Inspection and Test Plan to the SNC-Lavalin Document Control (for QA and Engineering review) as well as to the Authorized Nuclear Inspector (ANI) for acceptance and identification of their Hold or Witness points, prior to the start of fabrication and or installation.

Quality Assurance Specialists and Discipline Engineers with appropriate knowledge and experience shall evaluate Supplier submitted procedures related to Inspection and Test Plans.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 51 of 73

Title:

Bellefonte Project - Quality Assurance Plan 9.2 Special Processes Upon receipt of procedures for special processes (such as Welding, Heat Treatment, Non-Destructive Examination (NDE) etc.) SLN Document Control shall log them into PM+

or MyTRAK as applicable, followed by Vendor Internal Coordination Review which includes acceptance by Quality Assurance and Engineering.

Welding Procedures The SLN qualified Supplier / Constructor shall ensure that welding is controlled in accordance with the Suppliers Quality Assurance program. Welding controls shall address;

Weld Procedure Specification

Procedure Qualification Records

Welder Performance Qualification

Weld Material Control

Recording of Welding Data Welding Procedure Specifications and Procedure Qualification Records shall be submitted to SLN for review and acceptance. Welding procedures shall meet the technical requirements as specified in the Modification Packages as appropriate.

Heat Treatment Procedures The SLN qualified Supplier / Constructor shall ensure heat treatment is controlled in accordance with the Supplier / Constructors Quality Assurance program. Heat treatments include;

Pre-heat temperature control

Post-heat temperature control

Post Weld Heat Treatment control Heat Treatment procedures shall be submitted to SLN for review and acceptance. Heat Treatment procedures shall meet the technical requirements as specified in the Modification Packages as appropriate.

Welding inter-pass temperature control shall be performed in accordance with the Weld Procedure Specification.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 52 of 73

Title:

Bellefonte Project - Quality Assurance Plan Nondestructive Examination Procedures The SLN qualified Supplier / Constructors Nondestructive Examination procedures shall be reviewed and accepted by a Quality Assurance Specialist and Discipline Engineer in accordance with operating procedure 2206-01-40-OP-0009 Evaluation of Supplier NDE Procedures.

The SLN qualified Supplier / Constructor shall ensure Nondestructive Examination shall be performed and controlled in accordance with the subcontractors accepted Quality Assurance program.

The subcontractor shall ensure that;

NDE procedures are approved by a Level III and qualified in accordance with ASME Section III and Section V.

NDE personnel are qualified in accordance with a written practice compliant with ASNT Recommended Practice Nos. SNT-TC-1A and/or CP-189, as appropriate

NDE personnel are qualified in accordance with the requirements of clause 2.1.1.

The subcontractor shall be responsible for specifying NDE requirements in procedures or instructions and submitted to SLN for review and acceptance.

Special Processes Not Covered by Existing Codes and Standards Special processes procedures or instructions not covered by existing codes and standards, or where quality requirements specified for an item exceed those of existing codes or standards, shall be reviewed and accepted by a SLN Quality Assurance Specialist and SLN Discipline Engineer as necessary.

The review shall ensure that the necessary requirements for qualifications of personnel, procedures, or equipment are specified or referenced in the procedures or instructions.

Records shall be maintained for the currently qualified personnel, processes and equipment of each special process.

Source Surveillance on Special Processes Project Quality Assurance Specialists shall perform source surveillance on activities performed by Suppliers as per procedure 2206-06-40*0P-0002 Performance of Quality Surveillance.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 53 of 73

Title:

Bellefonte Project - Quality Assurance Plan 10 Inspection 10.1 General Requirements Quality Assurance Specialists shall ensure that inspections required to verify conformance of an item or activity to specified requirements, or continued acceptability, are executed. Characteristics subject to inspection and inspection methods shall be specified. Inspection results shall be documented. Quality Assurance Specialists shall confirm that inspection for acceptance shall be performed by qualified persons other than those who performed or directly supervised the work being inspected.

10.2 Inspection Requirements Quality Assurance Specialists shall ensure that inspection requirements and acceptance criteria include specified requirements contained in the applicable design documents and where required, accepted by the customer.

10.3 Inspection and Hold Points Quality Assurance Specialists shall ensure that specific hold points are indicated in the Inspection and Test Plan. In addition, work shall not be allowed to proceed beyond specified hold points unless consent to waive the specified hold point is obtained and recorded prior to continuation of work beyond the designated hold point.

10.4 Inspection Planning Planning Quality Assurance Specialists shall ensure that the characteristics to be inspected, methods of inspection, and acceptance criteria are identified during the inspection planning process. For items stamped with the ASME Certification Mark, an Inspection and Test Plan in conjunction with a Surveillance Plan shall be prepared by a Quality Assurance Specialist. Where SLN is purchasing a completed item, a Surveillance Plan is sufficient to document inspection planning requirements.

Sampling (Non ASME Work)

Quality Assurance Specialists shall ensure that sampling procedures, when used, are based upon valid statistical methods and contain reference to governing standards.

Statistical techniques are not used other than in the sampling plans identified in 2206 30-OP-0009 Receiving Inspection.

10.5 In Process Inspection Quality Assurance Specialists shall ensure that the inspection of items under fabrication, installation, or otherwise in-process is performed by the qualified supplier and as indicated in the Surveillance Plan. If inspection of processed items is impossible or disadvantageous, Quality Assurance Specialists shall observe the fabricator or installers use of indirect control or monitoring of processing methods, equipment, and personnel.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 54 of 73

Title:

Bellefonte Project - Quality Assurance Plan Both inspection and process monitoring shall be provided when control is inadequate without both.

10.6 Final Inspections Resolution of Non-conformance Quality Assurance Specialists shall ensure that final inspections include a record of review of the results and resolution of non-conformance identified by prior inspections.

Non-conformances shall be resolved in accordance with Clause 0.

Inspection Requirements Quality Assurance Specialists shall ensure that completed items are inspected for completeness, markings, calibration, adjustments, protection from damage, or other characteristics as required to verify the quality of the item and conformance of the item to specified requirements.

Modifications, Repairs, or Replacement Quality Assurance Specialists shall ensure that any modifications, repairs, or replacements, of items performed subsequent to final inspection shall require re-inspection and re-test, to verify acceptability 10.7 Records Quality Assurance Specialists shall ensure that records are established, maintained, and as a minimum, identify the following:

the item inspected,

date of inspection,

procedure number and revision level for the activity,

Quality Assurance Specialist,

type of observation,

results or acceptability, and

reference to information on action taken in connection with non-conformances.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 55 of 73

Title:

Bellefonte Project - Quality Assurance Plan 11 Test Control 11.1 General Requirements Tests required to verify conformance of an item to specified requirements and to demonstrate satisfactory performance for service shall be planned and executed.

Characteristics to be tested and test methods to be employed shall be specified. Test results shall be documented and their conformance with acceptance criteria shall be evaluated. 2206-06-40*0P-0002 Performance of Quality Surveillance is the applicable procedure.

11.2 Test Requirements The Quality Assurance Specialist shall ensure that all test requirements are appropriately planned and controlled. Test requirements shall be documented in a Surveillance Plan listed on the Inspection and Test Plan. Inspection and Test Plans provided to SLN by a supplier of an item or service shall be accepted in accordance with Clause 9 Controls applied to Inspection and Test Plans shall include:

Test requirements and acceptance criteria shall include as appropriate: prototype qualification tests, production tests, proof tests prior to installation, construction tests, pre-operational tests, operational tests, and computer program tests such as software verification and validation, factory acceptance tests, site acceptance tests, and in-use tests.

Required test shall be controlled under appropriate environmental conditions using tools and equipment necessary to conduct the test in a manner to fulfill test requirements and acceptance criteria. The tests performed shall obtain the necessary data with sufficient accuracy for evaluation and acceptance.

Test requirements and acceptance criteria shall be based upon specified requirements contained in applicable approved design documents, or other pertinent technical documents.

If temporary changes to the approved configuration of a facility are required for testing purposes, approval by the design authority is required prior to performing the test.

11.3 Test Procedures The requirements of this section do not apply to the testing of computer programs, computer hardware or computer operating systems. Quality Assurance Specialist shall ensure that test procedures include the following, as appropriate:

Test configuration and test objectives, provisions for assuring prerequisites and suitable environmental conditions are met and adequate instrumentation is available and used, and necessary monitoring is performed. Prerequisites shall include the following, as applicable: calibrated instrumentation, appropriate equipment, trained personnel, condition of test equipment and the item to be tested, suitable environmental conditions, and provision for data acquisition.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 56 of 73

Title:

Bellefonte Project - Quality Assurance Plan

As an alternative to (a) above, appropriate sections of related documents, such as ASTM or IEEE methods, supplier manuals, equipment maintenance instructions, or approved drawings or travelers with acceptance criteria, can be used.

11.4 Performance of the Component Pressure Test The component pressure test shall be subcontracted and performed by the supplier fabricating the item. The test requirements and acceptance criteria shall be included in procurement documents.

The Quality Assurance Specialist performing source verification shall be responsible for supervising, witnessing, and accepting the pressure test with ANI involvement.

The Quality Assurance Specialist shall ensure that the test is controlled in accordance with a documented procedure accepted by SLN and the suppliers approved Quality Assurance Program.

11.5 Test Results The Quality Assurance Specialist shall ensure that test results are documented and evaluated by the supplier, the ANI, or Customer, to assure that test requirements have been satisfied prior to signing the suppliers pressure test report.

11.6 Test Records The Quality Assurance Specialist shall ensure that component pressure test records are established and maintained to indicate the ability of the item to satisfactorily perform its intended function or to meet its documented requirements. The Component test record shall identify the following:

Item tested;

Date of test;

Test personnel

Type of observation;

Test Procedure and revision used;

Results and acceptability;

Action taken for any deviations noted;

Person evaluating test results;

Action taken in connection with any deviations, and

Gauges or instrument identification.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 57 of 73

Title:

Bellefonte Project - Quality Assurance Plan 11.7 Certification of ASME Code Data Report and Application of Certification Mark The Project Engineering Manager shall determine when the Data Report for the Code item is required to be registered with the National Board of Boiler and Pressure Vessel Inspectors at 1055 Crupper Avenue, Columbus, Ohio 43229-1183 from the Customers purchase order document requirements.

ASME Code Data Reports shall be included in the History Docket as lifetime (permanent) records in accordance with 2206-01-20-0P-0004, Permanent Records - History Docket -

History File. All Data Reports and referenced records shall be available to the ANI and enforcement authority having jurisdiction at the location of the nuclear power plant site.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 58 of 73

Title:

Bellefonte Project - Quality Assurance Plan 12 Control of Measuring and Test Equipment 12.1 General Requirements Tools, gages, instruments, and other measuring and test equipment used for activities affecting quality shall be controlled, calibrated at specific periods, adjusted and maintained to required accuracy limits.

Calibration and control measures may not be required for rulers, tape measures, levels, and other such devices, if such equipment provides adequate accuracy.

Periodic checks of equipment to check calibration is required. New measuring and test equipment shall be calibrated prior to use and registered in the calibration log 2206-01-30-0P-0016 Control of Measuring and Test Equipment (M&TE) applies to all Tools, Gauges and Instruments and other M&TE under the control of SLN. The Quality Assurance Specialist is responsible for selecting M& TE of the correct type, range, accuracy and tolerance to accomplish the function of determining conformance to specified quality requirements and to review and accept calibration records from supplier of calibration services.

12.2 Selection The organization performing the work activity shall be responsible for selection of measuring and test equipment to assure that such equipment is of proper type, range, accuracy, and tolerance to accomplish the required measurements for determining conformance to specified requirements. The process shall be controlled in accordance with the organizations Quality Assurance Program performing the work.

12.3 Calibration and Control Calibration and control of Measuring and Test Equipment shall be in accordance with the applicable Quality Assurance Program of the entity responsible for the work.

During surveillance or audit of the calibration services supplier, Quality Assurance Specialists shall ensure that documented calibration procedures include appropriate controls for measuring and test equipment.

Measuring and test equipment shall be traceable to its application and use.

When measuring and test equipment are found to be out of calibration, an evaluation, shall be made and documented including the validity of previously inspection or test results and the acceptability of items previously inspected or tested. Appropriate action shall be taken on the equipment and any affected items including removing the measuring and test equipment from service and quarantining any affected items.

Measuring and test equipment shall be properly handled and stored in accordance with 2206-06-30-0P-0001 Storage and Handling.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 59 of 73

Title:

Bellefonte Project - Quality Assurance Plan 12.4 Records Measuring and test equipment shall be suitably marked, tagged, labeled, or otherwise identified to indicate calibration status and establish traceability to calibration records.

Status indicators must be inspected prior to use to ensure that only calibrated measuring and test equipment is used.

12.5 Calibration Services Suppliers providing calibration services shall be qualified in accordance with SLN Operating Procedure 2206-06-30-0P-0003 Evaluation and Selection of Suppliers

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 60 of 73

Title:

Bellefonte Project - Quality Assurance Plan 13 Handling, Storage and Shipping Handling, storage, cleaning, packaging, shipping and preservation of items shall be controlled to prevent damage or loss and to minimize deterioration. 2206-06-30-0P-0001 Storage and Handling applies for the control of storage and handling to preserve items from the time of their receipt to prevent their damage, deterioration, or loss when in the custody and control of SNC-Lavalin Nuclear Inc. (SLN).

Items can come under the custody of SLN through a number of methods as follows:

From a supplier against a SLN purchase order; As 'free issue' from a Customer or Owner; Returned by a SLN qualified constructor I supplier after completion of work.

Procurement personnel are responsible for receiving and the Quality Assurance Specialist shall perform receiving inspection in accordance with operating procedure 2206-01-30-0P- 0009, Receiving Inspection.

Engineering shall specify special instructions related to preventing damage or loss, or minimizing item deterioration, equipment and material in EQRs, Technical Specifications and Drawings. Such requirements for handling, storage and preservation of SLN purchased items shall be defined in technical documents prepared in accordance with operating procedure 2206-07-20-0P-0001, Preparation of Engineering Documents by the Discipline Engineer. The technical documents shall consider the need for any special equipment (such as containers, shock absorbers, and accelerometers) and/or special protective environments (such as inert gas atmosphere, specific moisture content levels, and temperature levels).

When items are to be free-issued to SLN, the Project Manager shall ensure the requirements are specified by the item's owner and those requirements are incorporated into project plans. All items shall be controlled from their receipt, through handling, storage and preservation (as required), until released for installation, to prevent their abuse, misuse, deterioration, or loss of means of identification.

The control of storage and handling must ensure the following:

Items are preserved from the time of their receipt to prevent their damage, deterioration or loss; Inspections are performed periodically and their results documented to ensure storage areas and the integrity of the items is maintained, as required; Appropriate instructions are available and implemented for any items requiring special handling or special tooling and equipment; Any special handling tools and equipment required are inspected and tested at specified times to verify they are adequately maintained.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 61 of 73

Title:

Bellefonte Project - Quality Assurance Plan 14 Inspection and Test Status 14.1 General Requirements The status of inspection and test activities shall be identified either on the items or in documents traceable to the items where it is necessary to assure that required inspections and tests are performed and to assure that items which have not passed the required inspections and tests are not inadvertently installed or used.

SLN Operating Procedure 2206-01-30-0P-0017 Inspection and Test Status describes the process to ensure that required inspections and tests are performed on items and to ensure that those that have not passed the required inspections and tests are not inadvertently installed, used, or operated. The status of inspection and test activities shall be identified either on the items or in documents traceable to them. The procedure applies to items while under the direct control of SNC-Lavalin Nuclear Inc. The procedure does not apply to items while under the control of SLN qualified suppliers including fabricators / constructors.

14.2 Status SNC-Lavalin Nuclear ensures that the inspection and test status of items shall be indicated using the following methods:

Application of a Status Tag; On the Inspection and Test Plan (ITP) or inspection records traceable to the item; At the Storage Location.

Upon request by project site personnel responsible for receiving, the Quality Assurance Specialist performs Receiving Inspection and uses the controlled form 2206-01-30-CF-0010, Receiving Report in accordance with 2206-01-30-0P-0009, Receiving Inspection.

In order to ensure that items that have not passed the required inspections and tests are not inadvertently installed or used, controls are in place to use status indication tags at the following stages at a project site warehouse:

Receiving Inspection Stage;

Handling and Storage Stage.

The Quality Assurance Specialist has the responsibility to perform receiving inspection in accordance with 2206-01-30-0P-0009, Receiving Inspection and apply, maintain and remove status indicators as required by this procedure.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 62 of 73

Title:

Bellefonte Project - Quality Assurance Plan 15 Control of Nonconforming Items and Services 15.1 General Requirements Item and process non-conformances that do not conform to specified requirements are controlled to prevent inadvertent use or installation or use. The controls shall provide for identification, documentation, evaluation, segregation when practical, and disposition of the nonconforming items, and for notification to the affected organizations.

Non-conformances shall be documented using Reporting Problems and Taking Action (ProAct) system as documented in ProAct Procedure, NU-912020-PRO-001. The ProAct nonconformance shall be sufficiently detailed to allow proper review, evaluation, and disposition by authorized personnel. The review, evaluation, and disposition shall be in accordance with the ProAct procedure to ensure that the nonconforming characteristics are reviewed and a recommended disposition is proposed and approved.

The Project Quality Assurance Manager shall ensure that work delivered to the jurisdiction of the United States of America, in accordance with ASME NQA-1, 10 CFR Part 50 - Appendix B, and 10 CFR Part 21 nonconformance reporting shall include:

notification of the nonconformance to the Nuclear Regulatory Commission in a timely manner, in compliance with the statutory reporting requirements appropriate training for all personnel involved in such work of the statutory reporting requirement of the Nuclear Regulatory Commission posting of contact information for the Nuclear Regulatory Commission in conspicuous areas of the project office SLNs qualified Supplier / Constructor shall process non-conformances as per their QA Program. Suppliers non-conformance/concessions and exceptions for dispositions for use as is or repair/rework to SLN through Document Control for acceptance as per 2206-01-20-OP-0003 Document Control Routines. The Technical Justification to support the recommendation shall be provided by SNC-Lavalin engineering as required.

Nonconforming items shall be evaluated and recommended dispositions shall be proposed.

Further processing, delivery, installation, or use of a nonconforming item shall be controlled pending the evaluation and an approved disposition by authorized personnel.

Personnel performing evaluations to determine a disposition shall have demonstrated competence in the specific area they are evaluating, have adequate understanding of the requirements and have access to pertinent background information.

Any BLN Project personnel can identify an undesirable condition. The initial report shall be sufficiently detailed to allow for proper review evaluation and disposition The Quality Manager shall evaluate the condition to determine if a Nonconformance Report is warranted.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 63 of 73

Title:

Bellefonte Project - Quality Assurance Plan 16 Corrective Action 16.1 General Requirements The Project Quality Assurance Manager shall ensure conditions adverse to quality are promptly identified and corrected. In the case of a significant condition adverse to quality, the cause of the condition shall be determined and corrective action taken to prevent recurrence.

16.2 Corrective Action Any SNC-Lavalin Nuclear project employee can identify an undesirable condition. The Director, Quality Assurance shall ensure that all such identified conditions are subject to screening and further processed in accordance with the Reporting Problems and Taking Action through ProAct Procedure, NU-912020-PRO-001. Any BLN Project personnel can identify an undesirable condition adverse to quality. The process and documentation of conditions adverse to quality shall be in accordance with the organizations Quality Assurance Program who identified the condition.

Significant conditions adverse to quality are defined as follows:

Conditions that could adversely impact health and safety of the public or environment;

Conditions that could have a significant impact on reliability, availability, or maintainability of the equipment or facility;

Conditions that could individually fall within the not significant classification, but have been identified as recurring adverse conditions as a result of trend analysis;

Based on judgment, the Quality Manager decides to classify a condition as significant that could otherwise be classified as not significant.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 64 of 73

Title:

Bellefonte Project - Quality Assurance Plan 16.3 Supplier Corrective Action Request Anytime the SNC-Lavalin discovers conditions adverse to quality associated with activities performed by suppliers, the Quality Manager shall ensure corrective action is requested using controlled form 2206-01-40-CF-0009, Supplier Corrective Action Request.

Anytime a Supplier / Constructor discovers conditions adverse to quality associated with activities performed by them or their sub-supplier, the Quality Manager shall ensure corrective action is requested, as required, by the Supplier / Constructors QA Plan.

For each adverse audit finding, the Lead Auditor shall fill out section I of the Controlled Form 2206-01-40-CF-0009, Supplier Corrective Action Request and issue to the Supplier for a response in accordance with 2206-01-40-OP-0004, Performance of Audits.

Applicable Procedures NU-912020-PRO-001, Reporting Problems and Taking Action through ProAct 2206-01-30-OP-0004 Stop Work Order NU-905010-PRO-001Customer Feedback 2206-07-30-OP-0004 Corrective Action for Design Errors 2206-01-30-OP-0013 Causal Analysis NU-904010-PRO-001 Lessons Learned

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 65 of 73

Title:

Bellefonte Project - Quality Assurance Plan 17 Quality Assurance Records 17.1 General Requirements All Quality Assurance records shall be indexed as soon as practical as the project executes by the Document Control Manager and controlled in accordance with 2206-01-20-OP-0002, Control of QA Records. These controls shall apply to the: generation, identification, authentication, storage, maintenance, and disposition, of quality assurance records.

Requirements and responsibilities for these activities shall be documented.

Quality assurance records may be in any medium such as, paper hard copy, magnetic, electronic or optical computer disc, photograph, or any combination thereof. The customer and Authorized Nuclear Inspector shall be provided with access to quality assurance records at all times.

17.2 Generation of Records Quality assurance records shall be complete, legible, and traceable to the associated items and activities and accurately reflect the work accomplished or information required.

Records to be generated, supplied, or maintained shall be specified in quality assurance program documents, such as design specifications, procurement documents, and test procedures.

17.3 Authentication of Records Documents shall be considered valid records only if stamped, initialed, or signed and dated by authorized personnel.

Corrections to documents shall be reviewed and approved by the responsible individuals from the originating or authorized organizations Electronic documents shall be authenticated as appropriate, with identification on the media, or authentication information contained within or linked to the document itself.

Following authentication, the quality assurance record shall be submitted to the Manager, Document Control for population of the index and storage.

17.4 Classification Records shall be classified as permanent or non-permanent by the owner or his agent when authorized.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 66 of 73

Title:

Bellefonte Project - Quality Assurance Plan 17.5 Receipt, Control and Retention of Records Records shall be retained in accordance operating procedure 2206-01-20-OP-0002, Control of QA Records.

Documented procedures shall be established for the receipt, transmittal, authentication and documenting of quality records submitted to the BLN Project by external organizations.

Radiographs shall not be reproduced.

17.6 Storage The Manager, Document Control shall establish records storage facilities in compliance with requirements of this section of the QAP, at the earliest practical time. The operating procedure 2206-01-20-0002, Control of QA Records shall include the following requirements:

A description of the storage area The filing system to be used A method for verifying that records received are in agreement with the transmittal document and that record received are legible Verifying that the records are those designated Records access Process for tracking records removed from the records storage facility Methodology for filing supplemental information and identifying and disposing of superseded records Protocol for records disposal Records shall be stored in facilities, container, or a combination thereof, constructed and maintained in a manner which protects them from loss, deterioration, destruction or damage from the following:

natural disasters such as winds, floods, or fires, environmental conditions such as high and low temperatures including humidity, infestation of insects, mold, or rodents.

The Manager, Document Control shall implement dual facilities. Records shall be maintained in a hard copy format and an electronic format as identified in 2206-01 OP-0002, Control of QA Records remote from each other to eliminate the chance exposure to a simultaneous hazard.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 67 of 73

Title:

Bellefonte Project - Quality Assurance Plan 17.7 Retention At the end of the retention period, non-permanent records exceeding their retention period may be destroyed as authorized by the Senior Vice-President, Operations, and the Director, Quality Assurance.

17.8 Maintenance of Records Records shall be complete, remain legible, readily identifiable, retrievable, and traceable to the item or activity to which they refer. Records shall be protected against loss, theft or deterioration by one or more of the following means:

fire resistant file cabinets; environmental controls applied to records storage areas; offsite storage of duplicate files; back-up of electronic files.

Changes to records shall be controlled by documented procedures. Additional controls will be applied to records from special processes such as radiographs, photographs, negatives, microfilm, and magnetic and optical media, to prevent damage from excessive light, stacking, electromagnetic fields, temperature, and humidity.

17.9 Records Turnover SLN shall maintain all permanent and non-permanent records while in their possession.

All permanent records resulting from procurement activities are compiled in HD/HF and provided to Operations for acceptance prior releasing items for site installation.

All Design Engineering Changes (EDC) have been processed as per agreement with ND.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 68 of 73

Title:

Bellefonte Project - Quality Assurance Plan 18 Audits 18.1 General Requirements The BLN project conducts internal audit and supplier audits at planned intervals to verify whether the Quality Assurance Program:

conforms to the documented requirements, conforms to the requirements of applicable standard and codes, for internal audit and independent assessments, i) conforms to the requirement of this QAP and supporting Quality Assurance Manuals ii) is effectively implemented and maintained, and for external audit, conforms to the Quality Assurance Program requirements established by a supplier.

In addition to the above requirements, internal and external audits will also consider assessment of objective evidence that final item meets specified requirement Operating procedure 2206-01-40-OP-0004, Performance of Audits, defines the responsibilities and requirements for planning and conducting audits, independent assessments, establishing records, and reporting results.

All personnel shall be qualified in accordance with BLN Projects Quality Assurance Program.

The BLN Project will not utilize third party audits provided by an external organization, as a basis for supplier qualification.

For each adverse audit finding, the Lead Auditor shall fill out section I of the Controlled Form 2206-01-40-CF-0009, Supplier Corrective Action Request and issue to the Supplier for a response in accordance with 2206-01-40-OP-0004, Performance of Audits.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 69 of 73

Title:

Bellefonte Project - Quality Assurance Plan 19 Bellefonte Deferred Construction Permit 19.1 General Requirements The SNC-Lavalin Bellefonte Quality Assurance Plan describes the top level policy that assigns major functional responsibilities for activities conducted by or for Nuclear Developments Bellefonte Units 1 and 2 (BLN) while the construction permits for the units remain in deferred status. The QAP describes the methods and establishes the administrative control requirements that meet applicable 10 CFR 50, Appendix B requirements, NRC Generic Letter 87-15, Policy Statement on Deferred Plants, and the BLN 1 & 2 construction permits as reinstated in accordance with the terms of the NRC order reinstating the BLN Units 1 & 2 construction permits, dated March 9, 2009.

This section is developed to take into account the unique requirements and commitments necessary to ensure effective quality assurance program implementation and oversight of BLN 1 & 2.

The execution and accountability for quality assurance for the BLN 1 & 2 units remains with SNC-Lavalin, but may be delegated to support contractors for specific tasks and activities. Contracted activities are implemented through a SNC-Lavalin approved contractor Nuclear Quality Assurance Manual (NQAM) or may be implemented through direct implementation of the SNC-Lavalin QA program through SNC-Lavalin procedures.

SNC-Lavalins review and approval of a contractor NQAM, and any changes thereto, ensures that regulatory requirements and SNC-Lavalin specific commitments of this QAP are met. SNC-Lavalin retains and exercises the overall responsibility for the establishment and execution of an effective QA program for BLN 1 & 2.

Procedures and instructions that implement the requirements of the QAP are developed prior to commencement of those activities and are reviewed and approved by SNC-Lavalin.

19.2 Scope/Applicability for Current Activities Deferred Plant Status This section applies to BLN 1& 2 plant activities while ND Development, LLC evaluates, maintains and preserves the units for the consideration of possible reactivation of construction and completion activities. SNC-Lavalin will take the actions necessary to maintain and preserve the units in order to maintain the option of plant reactivation in accordance with Generic Letter 87-15, Policy Statement on Deferred Plants and the terms of the NRC order reinstating the BLN Units 1 & 2 construction permits, dated March 9, 2009.

Basic guidelines for activities conducted at Bellefonte during this period are listed below:

No physical work which advances construction status will be performed and no completion credit will be taken for any asset preservation activities performed.

Physical work on permanent plant SSCs will be limited to work necessary for maintenance and preservation of plant assets.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 70 of 73

Title:

Bellefonte Project - Quality Assurance Plan

The construction configuration management tool, Engineering/Construction Monitoring and Documentation system (ECM&D) will not be modified to reflect advancement of construction status.

The ECM&D will be modified to reflect correct status of equipment, e.g., ECM&D status will be changed to remove completion status that is not consistent with current plant construction status (examples: where a component was previously installed,

but subsequently removed by investment recovery(IR) activities; or lifting of a previously landed lead during maintenance related activities).

The BLN ASME Section III N stamp has been surrendered, and the ASME QAM is not active.. If active construction is resumed, the ASME Section III program will be re-established, most likely by an Engineering, Procurement and Construction (EPC) contractor. Should an ASME code system require maintenance or modification to support operation or PM activities required while in deferred status, configuration control records will be modified to reflect work done where existing QA records are invalidated. Additionally, work performed on ASME systems will be identified for future use and evaluation in re-establishing the ASME Section III QA program.

Most material purchased to perform maintenance and PM program activities while in deferred status will be procured to commercial standards and will be installed using procedure, Control of Temporary Installation or Omission (TIO) process. Some material may be procured to applicable quality requirements for future use in permanent plant applications should active construction be resumed.

No activities which will require NDE are expected to be performed during deferred plant status however informational NDE for the purpose of Detailed Scoping Estimating Planning (DSEP) may be performed.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 71 of 73

Title:

Bellefonte Project - Quality Assurance Plan 19.3 Organization The following sections describe the reporting relationships, functional responsibilities, and authorities for organizations implementing and supporting the Nuclear Quality Assurance Program as it applies to BLN Units 1 & 2 in a terminated or deferred plant status.

Bellefonte Owner, Nuclear Development The Bellefonte Owner is responsible for ensuring all requirements associated with the Bellefonte Deferred Construction permit are met. The Owner may delegate the specific responsibilities to the SNC-Lavalin Engineering, Procurement and Construction Management (EPCM) organization provided they maintain a 10CFR Appendix B QA program with attendant independent oversight performed by the SNC-Lavalin Quality Assurance organization.

Chief Nuclear Officer, SNC-Lavalin Nuclear (CNO)

The CNO is responsible for SNC-Lavalins programs and projects which include all aspects of design, construction and operation of the Bellefonte nuclear plants. The CNO is also responsible for all technical and administrative support activities provided by SNC-Lavalin and contractors.

Project Director, BLN Project The SNC-Lavalin Bellefonte Project Director responsible for the BLN Project, reports to the SNC-Lavalin CNO, and is responsible for the overall implementation of the project, ensuring the quality assurance requirements in the areas specified by this QAP for BLN 1 and 2 plant activities are met.

Director, Quality Assurance SNC-Lavalin Nuclear The Director, Quality Assurance, is responsible for ensuring that the SNC-Lavalin BLN QA organization is sized commensurate with assigned duties and responsibilities. This is accomplished through the use of a dedicated and experienced QA organization performing oversight activities both onsite and offsite.

The SNC-Lavalin Nuclear Quality Assurance organization is responsible for independently planning and performing audit activities to verify the effective implementation of the QAP described in this document for BLN 1 and 2 activities including, but not limited to engineering, QA/QC, licensing, document control, corrective action program, and procurement that support retention of the deferred construction permit for BLN-1 and 2.

The Director, Quality Assurance shall review results of all completed audits, ensure findings are properly documented and shall review results of the audit with the Bellefonte Owner, ND.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 72 of 73

Title:

Bellefonte Project - Quality Assurance Plan 19.4 Deferred Permit Procedures During the period that BLN units 1 & 2 remain in terminated or deferred status as described in Generic Letter 87-15, Policy Statement on Deferred Plants the Quality Assurance elements described in this section and the body of the QAP will be accomplished through written, reviewed and approved procedures. At minimum, procedures shall be in place for the following activities; Organization Roles and Responsibilities of the organization shall be defined.

QA Program QA Plan shall contain the QA organizational roles and responsibilities, equipment covered by the QA plan shall be identified and personnel performing work and audits shall be trained and qualified.

Document and QA Record Control Documents shall be retained with processes in place for configuration control, including any procurement related documents.

Corrective Action Program Any corrective actions adverse to quality shall be maintained in Corrective Action program.

Material Storage and Handling Procedures shall be in place to ensure material, parts and equipment is procured, stored and handled correctly with provisions for non-conformance also contained in procedures.

Equipment Maintenance Procedures, instructions and drawings shall be in place to ensure that any maintenance performed on plant equipment is conducted properly, measuring and test equipment properly maintained and calibrated, and equipment is properly identified and controlled.

Records associated with maintenance shall be retained including any test or inspection reports or results.

Site procedures that were not used in the period of deferral before the construction permits were withdrawn and placed in inactive status. As activities necessary to consider the viability of construction completion are required, the applicable procedures will be reactivated, reviewed and reissued prior to the conduct of the activity.

Site Security Program providing controls for general access to site.

Document Identification Revision 152918-0000-00000-38QP-0001 00 Date Effective:

2018.10.18 Page 73 of 73

Title:

Bellefonte Project - Quality Assurance Plan 19.5 Audits Periodic audits to ensure all required for maintaining the deferred construction permit shall be conducted on a frequency of at least annually. The audits shall be performed by qualified and appropriately trained QA personnel. Problems including conditions adverse to quality are documented through the corrective action program.

The results of assessments are documented and reported to appropriate levels of management in the ND and SNC-Lavalin organizations.

Records maintain sufficient detail to provide adequate documentation of assessed activities. Follow up verifications or additional assessments may be conducted as necessary to ensure that required corrective action has been taken.

The audit will evaluate the following:

Construction Permit and Deferred Status Activities - evaluate for reasonable assurance that activities authorized by the permit are in compliance

Quality Assurance Program Requirements - evaluate the QA plan requirements for implementation and adequacy of records, documents and procedures. Verify the implementation and overall effectiveness of the QA plan.

Maintenance and Equipment Preservation Activities - verify the established measure to control maintenance and equipment preservation in plant deferred status

Corrective Action - verify established measures in place to control non-conformances, deficiencies and conditions adverse to quality 19.6 Plant Equipment Policy An important factor in considering the viability of construction reactivation and completion includes the impact of equipment age on its continued suitability for use. Considerations regarding age degradation due to design life, outdated or obsolete equipment, design improvements, any impact associated with resource recovery activities, and economic feasibility to replace rather than preserve equipment indefinitely under a lay-up program must be taken into account given the age of certain existing equipment. For these reasons, in August 2003, the Tennessee Valley Authority (TVA) submitted, and in May 2004 the NRC approved a change to the QAP that allowed preventive maintenance to be terminated on selected equipment and to allow that equipment to be entered into the corrective action program as deferred equipment. SNC-Lavalin procedure controls prohibit and will continue to prohibit deferred equipment from being used in nuclear safety related applications without further evaluation and having been fully restored or replaced.

Structures, systems or components that have been affected in the course of resource recovery activities will likewise be entered in to the corrective action program and prohibited from being returned to service without evaluation and having been restored or replaced.

APPLICATION FOR ORDER APPROVING CONSTRUCTION PERMIT TRANSFERS AND CONFORMING CONSTRUCTION PERMIT AMENDMENTS ATTACHMENT 2 CONSTRUCTION PERMIT (CHANGES)

Bellefonte Nuclear Plant, Unit 1 NRC CONSTRUCTION PERMIT NO. CPPR-122 DOCKET NO. 50-438

UNITED STATES ATOMIC ENERGY COMMISSION WASHINGTON, D.C. 20545 TENNESSEE VALLEY AUTHORITY NUCLEAR DEVELOPMENT, LLC DOCKET NO. 50-438 BELLEFONTE NUCLEAR PLANT, UNIT 1 CONSTRUCTION PERMIT Construction Permit No. CPPR-122 1.

The Atomic Energy Commission (the Commission) having found that:

A.

The application for construction permit complies with the requirements of the Atomic Energy Act of 1954, as amended, and the rules and regulations of the Commission, there is reasonable assurance that the activities authorized by the permit will be conducted in compliance with the rules and regulations of the Commission, and all required notifications to other agencies or bodies have been duly made:

B.

The Tennessee Valley Authority Nuclear Development, LLC (the applicant) has described the proposed design of the Bellefonte Nuclear Plant, Unit 1 (the facility), including, but not limited to, the principal architectural and engineering criteria for the design and has identified the major features or components incorporated therein for the protection of the health and safety of the public; C.

Such further technical or design information as may be required to complete the safety analysis, and which can reasonably be left for later consideration, will be supplied in the final safety analysis report; D.

Safety features or components, if any, which require research and development have been described by the applicant and the applicant has identified, and there will be conducted, a research and development program reasonably designed to resolve any safety questions associated with such features or components; E.

On the basis of the foregoing, there is reasonable assurance that (i) such safety questions will be satisfactorily resolved at or before the latest date stated in the application for completion of construction of the proposed facility and (ii) taking into consideration the site criteria contained in 10 CFR Part 100, the proposed facility can be constructed and operated at the proposed location without undue risk to the health and safety of the public;

- 2 -

F.

The applicant is technically qualified to design and construct the proposed facility; G.

The applicant is financially qualified to design and construct the proposed facility; H. The issuance of a permit for the construction of the facility will not be inimical to the common defense and security or to the health and safety of the public; and I. After weighing the environmental, economic, technical and other benefits of the facility against environmental and other costs and considering available alternatives, the issuance of a construction permit subject to the conditions for protection of the environment set forth herein is in accordance with 10 CFR Part 50, Appendix D of the Commission's regulations and all applicable requirements have been satisfied.

2.

Pursuant to Section 103 of the Atomic Energy Act of 1954, as amended (the Act), and Title 10, Chapter I, Code of Federal Regulations, Part 50, "Licensing of Production and Utilization Facilities," and pursuant to the Initial Decision of the Atomic Safety and Licensing Board, dated December 23, 1974, the Atomic Energy Commission (the Commission) hereby issues a construction permit to the applicant for a utilization facility designed to operate at 3600 megawatts thermal as described in the application and amendments thereto (the application) filed in this matter by the applicant and as more fully described in the evidence received at the public hearing upon the application.

The facility, known as the Bellefonte Nuclear Plant, Unit 1 will be located on the applicant's site in Jackson County, Alabama.

3.

This permit shall be deemed to contain and be subject to the conditions specified in Sections 50.54 and 50.55 of said regulations; is subject to all applicable provisions of the Act, and rules, regulations, and orders of the Commission now or hereafter in effect, and is subject to the conditions specified or incorporated below:

A.

The earliest date for the completion of the facility is June 1, 1979, and the latest date for completion is October 1, 2011 2029.

B.

The facility shall be constructed and located at the site as described in the application, in Jackson County, Alabama.

C.

This construction permit authorizes the applicant to construct the facility described in the application and the hearing record, in accordance with the principal architectural and Amended by NRC Order dated March 4, 2003

APPLICATION FOR ORDER APPROVING CONSTRUCTION PERMIT TRANSFERS AND CONFORMING CONSTRUCTION PERMIT AMENDMENTS ATTACHMENT 3 CONSTRUCTION PERMIT (CLEAN)

Bellefonte Nuclear Plant, Unit 1 NRC CONSTRUCTION PERMIT NO. CPPR-122 DOCKET NO. 50-438

UNITED STATES ATOMIC ENERGY COMMISSION WASHINGTON, D.C. 20545 NUCLEAR DEVELOPMENT, LLC DOCKET NO. 50-438 BELLEFONTE NUCLEAR PLANT, UNIT 1 CONSTRUCTION PERMIT Construction Permit No. CPPR-122 1.

The Atomic Energy Commission (the Commission) having found that:

A.

The application for construction permit complies with the requirements of the Atomic Energy Act of 1954, as amended, and the rules and regulations of the Commission, there is reasonable assurance that the activities authorized by the permit will be conducted in compliance with the rules and regulations of the Commission, and all required notifications to other agencies or bodies have been duly made:

B.

The Nuclear Development, LLC (the applicant) has described the proposed design of the Bellefonte Nuclear Plant, Unit 1 (the facility), including, but not limited to, the principal architectural and engineering criteria for the design and has identified the major features or components incorporated therein for the protection of the health and safety of the public; C.

Such further technical or design information as may be required to complete the safety analysis, and which can reasonably be left for later consideration, will be supplied in the final safety analysis report; D.

Safety features or components, if any, which require research and development have been described by the applicant and the applicant has identified, and there will be conducted, a research and development program reasonably designed to resolve any safety questions associated with such features or components; E.

On the basis of the foregoing, there is reasonable assurance that (i) such safety questions will be satisfactorily resolved at or before the latest date stated in the application for completion of construction of the proposed facility and (ii) taking into consideration the site criteria contained in 10 CFR Part 100, the proposed facility can be constructed and operated at the proposed location without undue risk to the health and safety of the public;

- 2 -

F.

The applicant is technically qualified to design and construct the proposed facility; G.

The applicant is financially qualified to design and construct the proposed facility; H. The issuance of a permit for the construction of the facility will not be inimical to the common defense and security or to the health and safety of the public; and I. After weighing the environmental, economic, technical and other benefits of the facility against environmental and other costs and considering available alternatives, the issuance of a construction permit subject to the conditions for protection of the environment set forth herein is in accordance with 10 CFR Part 50, Appendix D of the Commission's regulations and all applicable requirements have been satisfied.

2.

Pursuant to Section 103 of the Atomic Energy Act of 1954, as amended (the Act), and Title 10, Chapter I, Code of Federal Regulations, Part 50, "Licensing of Production and Utilization Facilities," and pursuant to the Initial Decision of the Atomic Safety and Licensing Board, dated December 23, 1974, the Atomic Energy Commission (the Commission) hereby issues a construction permit to the applicant for a utilization facility designed to operate at 3600 megawatts thermal as described in the application and amendments thereto (the application) filed in this matter by the applicant and as more fully described in the evidence received at the public hearing upon the application.

The facility, known as the Bellefonte Nuclear Plant, Unit 1 will be located on the applicant's site in Jackson County, Alabama.

3.

This permit shall be deemed to contain and be subject to the conditions specified in Sections 50.54 and 50.55 of said regulations; is subject to all applicable provisions of the Act, and rules, regulations, and orders of the Commission now or hereafter in effect, and is subject to the conditions specified or incorporated below:

A.

The earliest date for the completion of the facility is June 1, 1979, and the latest date for completion is October 1, 2029.

B.

The facility shall be constructed and located at the site as described in the application, in Jackson County, Alabama.

C.

This construction permit authorizes the applicant to construct the facility described in the application and the hearing record, in accordance with the principal architectural and Amended by NRC Order dated March 4, 2003

APPLICATION FOR ORDER APPROVING CONSTRUCTION PERMIT TRANSFERS AND CONFORMING CONSTRUCTION PERMIT AMENDMENTS ATTACHMENT 4 CONSTRUCTION PERMIT (CHANGES)

Bellefonte Nuclear Plant, Unit 2 NRC CONSTRUCTION PERMIT NO. CPPR-123 DOCKET NO. 50-439

UNITED STATES ATOMIC ENERGY COMMISSION WASHINGTON, D.C. 20545 TENNESSEE VALLEY AUTHORITY NUCLEAR DEVELOPMENT, LLC DOCKET NO. 50-439 BELLEFONTE NUCLEAR PLANT, UNIT 2 CONSTRUCTION PERMIT Construction Permit No. CPPR-123 1.

The Atomic Energy Commission (the Commission) having found that:

A.

The application for construction permit complies with the requirements of the Atomic Energy Act of 1954, as amended, and the rules and regulations of the Commission, there is reasonable assurance that the activities authorized by the permit will be conducted in compliance with the rules and regulations of the Commission, and all required notifications to other agencies or bodies have been duly made:

B.

The Tennessee Valley Authority Nuclear Development, LLC (the applicant) has described the proposed design of the Bellefonte Nuclear Plant, Unit 2 (the facility), including, but not limited to, the principal architectural and engineering criteria for the design and has identified the major features or components incorporated therein for the protection of the health and safety of the public; C.

Such further technical or design information as may be required to complete the safety analysis, and which can reasonably be left for later consideration, will be supplied in the final safety analysis report; D.

Safety features or components, if any, which require research and development have been described by the applicant and the applicant has identified, and there will be conducted, a research and development program reasonably designed to resolve any safety questions associated with such features or components; E.

On the basis of the foregoing, there is reasonable assurance that (i) such safety questions will he satisfactorily resolved at or before the latest date stated in the application for completion of construction of the proposed facility and (ii) taking into consideration the site criteria contained in 10 CFR Part 100, the proposed facility can be constructed and operated at the proposed location without undue risk to the health and safety of the public; F.

The applicant is technically qualified to design and construct the proposed facility; G.

The applicant is financially qualified to design and construct the proposed facility; H.

The issuance of a permit for the construction of the facility will not be inimical to the common defense and security or to the health and safety of the public; and I.

After weighing the environmental, economic, technical and other benefits of the facility against, environmental and other costs and considering available alternatives, the issuance of a construction permit subject to the conditions for protection of the environment set forth herein is in accordance with 10 CFR Part 50, Appendix D of the Commission's regulations and all applicable requirements have been satisfied.

2.

Pursuant to Section 103 of the Atomic Energy Act of 1954, as amended (the Act), and Title 10, Chapter I, Code of Federal Regulations, Part 50, "Licensing of Production and Utilization Facilities," and pursuant to the Initial Decision of the Atomic Safety and Licensing Board, dated December 23, 1974, the Atomic Energy Commission (the Commission) hereby issues a construction permit to the applicant for a utilization facility designed to operate at 3600 megawatts thermal as described in the application and amendments thereto (the application) filed in this matter by the applicant and as more fully described in the evidence received at the public hearing upon the application. The facility, known as the Bellefonte Nuclear Plant, Unit 2 will be located on the applicant's site in Jackson County, Alabama.

3.

This permit shall be deemed to contain and be subject to the conditions specified in Sections 50.54 and 50.55 of said regula-tions; is subject to all applicable provisions of the Act, and rules, regulations, and orders of the Commission now or hereafter in effect, and is subject to the conditions specified or incor-porated below:

A.

The earliest date for the completion of the facility is March 1_ 1980 and the latest date for completion is October 1, 2014 2029.

B.

The facility shall be constructed and located at the site as described in the application, in Jackson County, Alabama.

C.

This construction permit authorizes the applicant to construct the facility described in the application and the hearing record, in accordance with the principal architectural and Amended by NRC Order dated March 4, 2003

APPLICATION FOR ORDER APPROVING CONSTRUCTION PERMIT TRANSFERS AND CONFORMING CONSTRUCTION PERMIT AMENDMENTS ATTACHMENT 5 CONSTRUCTION PERMIT (CLEAN)

Bellefonte Nuclear Plant, Unit 2 NRC CONSTRUCTION PERMIT NO. CPPR-123 DOCKET NO. 50-439

UNITED STATES ATOMIC ENERGY COMMISSION WASHINGTON, D.C. 20545 NUCLEAR DEVELOPMENT, LLC DOCKET NO. 50-439 BELLEFONTE NUCLEAR PLANT, UNIT 2 CONSTRUCTION PERMIT Construction Permit No. CPPR-123 1.

The Atomic Energy Commission (the Commission) having found that:

A.

The application for construction permit complies with the requirements of the Atomic Energy Act of 1954, as amended, and the rules and regulations of the Commission, there is reasonable assurance that the activities authorized by the permit will be conducted in compliance with the rules and regulations of the Commission, and all required notifications to other agencies or bodies have been duly made:

B.

The Nuclear Development, LLC (the applicant) has described the proposed design of the Bellefonte Nuclear Plant, Unit 2 (the facility), including, but not limited to, the principal architectural and engineering criteria for the design and has identified the major features or components incorporated therein for the protection of the health and safety of the public; C.

Such further technical or design information as may be required to complete the safety analysis, and which can reasonably be left for later consideration, will be supplied in the final safety analysis report; D.

Safety features or components, if any, which require research and development have been described by the applicant and the applicant has identified, and there will be conducted, a research and development program reasonably designed to resolve any safety questions associated with such features or components; E.

On the basis of the foregoing, there is reasonable assurance that (i) such safety questions will he satisfactorily resolved at or before the latest date stated in the application for completion of construction of the proposed facility and (ii) taking into consideration the site criteria contained in 10 CFR Part 100, the proposed facility can be constructed and operated at the proposed location without undue risk to the health and safety of the public; F.

The applicant is technically qualified to design and construct the proposed facility; G.

The applicant is financially qualified to design and construct the proposed facility; H.

The issuance of a permit for the construction of the facility will not be inimical to the common defense and security or to the health and safety of the public; and I.

After weighing the environmental, economic, technical and other benefits of the facility against, environmental and other costs and considering available alternatives, the issuance of a construction permit subject to the conditions for protection of the environment set forth herein is in accordance with 10 CFR Part 50, Appendix D of the Commission's regulations and all applicable requirements have been satisfied.

2.

Pursuant to Section 103 of the Atomic Energy Act of 1954, as amended (the Act), and Title 10, Chapter I, Code of Federal Regulations, Part 50, "Licensing of Production and Utilization Facilities," and pursuant to the Initial Decision of the Atomic Safety and Licensing Board, dated December 23, 1974, the Atomic Energy Commission (the Commission) hereby issues a construction permit to the applicant for a utilization facility designed to operate at 3600 megawatts thermal as described in the application and amendments thereto (the application) filed in this matter by the applicant and as more fully described in the evidence received at the public hearing upon the application.

The facility, known as the Bellefonte Nuclear Plant, Unit 2 will be located on the applicant's site in Jackson County, Alabama.

3.

This permit shall be deemed to contain and be subject to the conditions specified in Sections 50.54 and 50.55 of said regulations; is subject to all applicable provisions of the Act, and rules, regulations, and orders of the Commission now or hereafter in effect, and is subject to the conditions specified or incorporated below:

A.

The earliest date for the completion of the facility is March 1_ 1980 and the latest date for completion is October 1, 2029.

B.

The facility shall be constructed and located at the site as described in the application, in Jackson County, Alabama.

C.

This construction permit authorizes the applicant to construct the facility described in the application and the hearing record, in accordance with the principal architectural and Amended by NRC Order dated March 4, 2000