140 APPENDIX R Nuclear Power Units by Nation Under Construction In Operation or on Order Gross MW Gross MW Nuclear Power Number Electrical Number Electrical Country Production GWh*
of Units Capacity of Units Capacity ShutdownArgentina 6,161 3 1,755 1 29 0 Armenia 2,411 1 408 0 0 1 P Bangladesh 0 0 0 1 1200 0 Belarus 0 0 0 2 2,388 0 Belgium 41,031 7 6,207 0 0 1 P Brazil 15,740 2 1,990 1 1,405 0 Bulgaria 15,549 2 2,000 0 0 4 P Canada 96,074 19 14,512 0 0 6 P China 247,469 39 36,959 18 21,145 0 Czech Republic 26,785 6 4,160 0 0 0 Finland 21,575 4 2,877 1 1,720 0 France 379,100 58 65,880 1 1,650 12 P Germany 72,163 7 10,013 0 0 29 P Hungary 15,219 4 2,000 0 0 0 India 35,000 22 6,780 7 5,300 0 Iran 6,366 1 1,000 0 0 0 Italy 0 0 0 0 0 4 P Japan 29,073 42 41,482 2 2,756 18 P Kazakhstan 0 0 0 0 0 1 PKorea, Republic of 141,098 24 23,518 4 5,600 1 P Lithuania 0 0 0 0 0 2 P Mexico 10,572 2 1,615 0 0 0 Netherlands 3,278 1 515 0 0 1 P Pakistan 7,867 5 1,430 2 2,200 0 Romania 10,561 2 1,411 0 0 0 Russia 187,499 37 30,159 6 4,919 6 P Slovakia 14,016 4 1,950 2 942 3 P Slovenia 5,968 1 727 0 0 0 South Africa 15,209 2 1,940 0 0 0 Spain 55,599 7 7,416 0 0 3 P 141 Sweden 63,063 8 8,622 0 0 5 P Switzerland 19,502 5 3,467 0 0 1 P Turkey 0 0 0 1 1200 0 Ukraine 85,576 15 13,835 2 2,178 4 P United Arab Emirates 0 0 0 4 5,600 0 United Kingdom 63,877 15 10,362 0 0 30 P United States 804,950 99 105,514 2 2,500 34 P Overview of Worldwide Nuclear Power Reactors-As of May 6, 2018 Nuclear Electricity Supplied (GWh) 2,487,981Net Installed Capacity (MWe) 393,843 Nuclear Power Reactors in Operation 450Nuclear Power Reactors in Long-Term Shutdown 0 Nuclear Power Reactors in Permanent Shutdown 166 Nuclear Power Reactors under Construction 58
- Annual electrical power production for 2017.
P = Permanent Shutdown Notes: Totals include reactors that are operable, under construction, or on order; the country's short-form name is used; and the ~gures are rounded to the nearest whole number. Sources: IAEA Power Reactor Information System Database; analysis compiled by the NRC. For more information go to https://www.iaea.org/pris/. Data are current as of May 2018; the next printed update will be in August 2019.
APPENDIX R Nuclear Power Units by Nation (continued)
Under Construction In Operation or on Order Gross MW Gross MW Nuclear Power Number Electrical Number Electrical Country Production GWh*
of Units Capacity of Units Capacity Shutdown In Operation Number Reactor Type of Units Net MWePressurized light-water reactors (PWR) 294 276,965Boiling light-water reactors (BWR) 75 72,941Heavy-water reactors, all types (HWR, PHWR) 49 24,598Light-water-cooled graphite-moderated reactor (LWGR) 15 10,219Gas-cooled reactors, all types (GCR) 14 7,720Liquid-metal-cooled fast breeder reactors (FBR) 3 1,400Total 450 393,843 Note: MWe values are rounded to the nearest whole number.Source: IAEA Power Reactor Information System Database, www.iaea.org Compiled by the NRC from IAEA data. Data are current as of May 2018. The next printed update will be in August 2019.
APPENDIX SNuclear Power Units by Reactor Type, Worldwide