ML18226A132
| ML18226A132 | |
| Person / Time | |
|---|---|
| Issue date: | 08/14/2018 |
| From: | Couret I L Office of Public Affairs |
| To: | |
| Meyd, Donald | |
| Shared Package | |
| ML18226A101 | List:
|
| References | |
| NUREG-1350 V30 | |
| Download: ML18226A132 (2) | |
Text
126 APPENDIX HOperating Nuclear Research and Test Reactors Regulated by the NRC Licensee Reactor Type Power Level Licensee Number Location OL Issued (kW) Docket NumberAerotest TRIGA (Indus) 250 R-98 San Ramon, CA 07/02/1965 05000228Armed Forces Radiobiology TRIGA 1,100 R-84 Research Institute 06/26/1962 05000170 Bethesda, MD Dow Chemical Company TRIGA 300 R-108 Midland, MI 07/03/1967 05000264 GE-Hitachi Tank 100 R-33 Sunol, CA 10/31/1957 05000073 Idaho State University AGN-201 #103 0.005 R-110 Pocatello, ID 10/11/1967 05000284 Kansas State University TRIGA 250 R-88 Manhattan, KS 10/16/1962 05000188 Massachusetts Institute HWR Reected 6,000 R-37 of Technology 06/09/1958 05000020 Cambridge, MA Missouri University of Science Pool 200 R-79 and Technology 11/21/1961 05000123 Rolla, MO National Institute of Nuclear Test 20,000 TR-5 Standards & Technology 05/21/1970 05000184 Gaithersburg, MDNorth Carolina State University Pulstar 1,000 R-120 Raleigh, NC 08/25/1972 05000297 Ohio State University Pool 500 R-75 Columbus, OH 02/24/1961 05000150Oregon State University TRIGA MARK II 1,100 R-106 Corvallis, OR 03/07/1967 05000243 Pennsylvania State University TRIGA 1,100 R-2 State College, PA 07/08/1955 05000005Purdue University Lockheed 12 R-87 West Lafayette, IN 08/16/1962 05000182 Reed College TRIGA MARK I 250 R-112 Portland, OR 07/02/1968 05000288 127 Rensselaer Polytechnic Institute Critical Assembly 0.1 CX-22 Troy, NY 07/03/1964 05000225 Rhode Island Atomic GE Pool 2,000 R-95 Energy Commission 07/23/1964 05000193 Narragansett, RITexas A&M University AGN-201M #106 0.005 R-23 College Station, TX 08/26/1957 05000059Texas A&M University TRIGA 1,000 R-83 College Station, TX 12/07/1961 05000128 U.S. Geological Survey TRIGA MARK I 1,000 R-113 Denver, CO 02/24/1969 05000274University of California/Davis TRIGA 2,300 R-130 Sacramento, CA 08/13/1998 05000607University of California/Irvine TRIGA MARK I 250 R-116 Irvine, CA 11/24/1969 05000326 University of Florida Argonaut 100 R-56 Gainesville, FL 05/21/1959 05000083 University of Maryland TRIGA 250 R-70 College Park, MD 10/14/1960 05000166 University of Massachusetts/Lowell GE Pool 1,000 R-125 Lowell, MA 12/24/1974 05000223 University of Missouri/Columbia Tank 10,000 R-103 Columbia, MO 10/11/1966 05000186 University of New Mexico AGN-201M #112 0.005 R-102 Albuquerque, NM 09/17/1966 05000252University of Texas TRIGA MARK II 1,100 R-129 Austin, TX 01/17/1992 05000602 University of Utah TRIGA MARK I 100 R-126 Salt Lake City, UT 09/30/1975 05000407 University of Wisconsin TRIGA 1,000 R-74 Madison, WI 11/23/1960 05000156Washington State University TRIGA 1,000 R-76 Pullman, WA 03/06/1961 05000027 Note: Data are current as of July 2018; the next printed update will be in August 2019.
APPENDIX HOperating Nuclear Research and Test Reactors Regulated by the NRC (continued)
Licensee Reactor Type Power Level Licensee Number Location OL Issued (kW) Docket Number