Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 1 of 15 Package Contents Specification for Safkeg-HS Package Design No 3977A Title Package Contents Specification for Safkeg-HS - Package Design No 3977A Number PCS 038 Issue I
File Ref PCS038-I-v3-Safkeg-HS-Contents Compiled Checked R A Vaughan A L Ferguson Approved Date 31 Mar 2018 R A Vaughan Croft Associates Ltd, F4 Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB. 01865 407740
Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 2 of 15 1 Specification of contents 1.1 General nature of contents The Safkeg-HS 3977A package is designed as a Type B(U) general purpose package for radioactive material.
The package is designed for radioactive material that emits neutron, alpha, beta or gamma radiation.
The contents may be in solid, liquid or gaseous form and carried in various inserts as specified in the Table 1 below.
Table 1 Contents Types Contents Type Designation Material Form Shielding Insert General Requirements for each Contents Type (1)
Activity Limits for each Contents Type CT-1 Solid HS-12x95-Tu Design No 3982 See Table 1-3-1 See Table 4-1 CT-2 Solid HS-31x114-Tu Design No 3985 See Table 1-3-2 See Table 4-2 CT-3 Gas HS-31x114-Tu Design No 3985 See Table 1-3-3 See Table 4-3 CT-4 Liquid (I-131)
HS-55x128-SS Design No 3987 with Titanium liner See Table 1-3-4 See Table 4-4 CT-5 Liquid (Mo-99)
HS-50x85-SS Design No 4081 in tungsten liner with Split Lid CV See Table 1-3-5 See Table 4-5 CT-6 Solid (thorium metal)
Split Lid CV fitted with seal plug No insert See Table 1-3-6 See Table 4-6 1
These tables are in the SARP [1].
Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 3 of 15 1.2 Shielding inserts The shielding inserts specified in Section 1 of the SARP for Safkeg-HS 3977A [1] and listed in Table 1 above are required for all contents.
Under NCT and HAC, the shielding inserts, together with the user defined product containers, provide confinement of the solid or liquid radioactive material.
1.3 Radionuclides included See Tables 4-x.
1.4 Quantity The maximum mass (and volume for gases) of each radionuclide carried in Type B quantities is detailed in Table 2 and Tables 4-x for specific Contents Types.
1.5 Activity limit The package activity limits for individual nuclides, according to the insert used, are given in Tables 4-x. The activity limit is determined in accordance with the methodology in Section 2 below except for CT-6 for which typical contents are given in Table 4-6.
1.6 Other limiting factors Various restrictions and limits of quantity of radionuclides apply according to the insert used and for the form of the radioactive material (solid, liquid or gas). These restrictions and contents limits are detailed in Section 1 of the SARP for Safkeg-HS 3977A in Section 1.2.2 in the tables for specific Contents Types.
2 Calculation of allowable contents The package activity limit in Tables 4-x is the least of the limits determined based on heat output, mass limit and shielding limit and, for gas contents, the limit based on allowable leakage under NCT or HAC.
2.1 Heat limits The heat limit for solid contents is 30 W and for liquid contents the heat limit is 5 W.
2.2 Mass limit The upper limit on the mass is different for each insert - as specified in section 1.4 above.
The maximum mass of the radionuclides is set at nominally 50% the mass of a steel cylinder that would fill the cavity of the insert (see Table 2).
Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 4 of 15 Table 2 Maximum mass of the radionuclides Shielding Insert Mass of a steel cylinder that would fill the cavity of the insert (g)
Maximum mass of the radionuclides (g)
HS-12x95-Tu Design No 3982 90 45 HS-31x114-Tu Design No 3985 690 345 HS-55x128-SS Design No 3987 with titanium liner 1,810 905 HS-50x85-SS Design No 4081 with tungsten liner 1,615 808 CV fitted with sealed plug (no insert) 3,500 1,750 2.3 Shielding limit The package design is such that the surface dose rate, as opposed to the TI, is the limiting factor under HAC. The shielding limits in Tables 4-x for each radionuclide are based on the assessments listed in Table 3.
Table 3 Shielding Limit of the radionuclides Contents Type Assessment CT-1, CT-2 (solids)
And CT-3 (gases)
Report CTR 2011/01 [2] provides the maximum activity to give the maximum allowable package surface dose rate (for, and n emitters) of 2mSv/h (200 mrem/h). These calculations are based on the worst case assumption of the radioactive material being a point source at the centre of the base of the insert (neglecting spacing due to use of product containers). This location has been shown to produce the highest package surface dose rate in report AMEC/SF6652/001 [3]. This shielding limit has been further adjusted to take into account some shielding calculation uncertainties as discussed in Croft report CTR 2013/09 [7].
CT-4 (Mo-99 in liquid)
The package surface dose rate has been determined in report AMEC/CRM37327/TN_001 [8].
These are the package limits to meet user requirements.
Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 5 of 15 Contents Type Assessment CT-5 (I-131 in liquid)
The package surface dose rate has been determined in report AMEC/CRM42622/TN_001.
These are the package limits to meet user requirements.
CT-6 (thorium metal)
The surface dose is given in Table 4-6 for a typ;ical activated thorium target. The dose data is taken from Atkins Report 5163778-HS-REP-001-001 which gives the dose rate per Ci for the radionuclides arising from a thorium metal target activated by proton bombardment.
2.4 Leakage limit For solid and liquid contents, the contents are completely contained as the O-ring seal of the CV meets the requirement of Leaktight as defined in ANSI N 14.5 [4].
2.5 Criticality Limits There are no fissile material in the contents for this package.
Package Contents Specification PCS 038 for Safkeg-HS Issue I Package Design No 3977A Page 6 of 15 3 References
[1]
CTR 2008/11, SARP for Safkeg-HS 3977A, Docket No. 71-9337
[2]
Croft, CTR 2011/01, Issue D, SAFKEG LS 3977A, Package Activity Limits Based on Shielding
[3]
AMEC/SF6652/001, Issue 2, Monte Carlo Modelling of Safkeg HS Container
[4]
ANSI N14.5, American National Standard for Radioactive Materials - Leakage Test on Packages for Shipment, American National Standards Institute, Inc., 1997
[5]
10CFR PART 71, Packaging And Transportation Of Radioactive Material, U.S.
Nuclear Regulatory Commission
[6]
CS 2012/05, Issue A, SAFKEG-HS 3977A - Gas contents limit for leaktight condition
[7]
CTR 2013/09, Issue C, Uncertainties Associated with the Proposed Shielding Calculation Method for the SAFKEG-HS 3977A Package
[8]
AMEC/CRM37327/TN-001, Issue 1, HS Container Shielding Assessment with I-131
[9]
AMEC/CRM42622/TN-001, Issue 1, HS Container Shielding Assessment with Mo-99
[10]
Atkins 5163778-HS-REP-001-001
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 7 of 15 Table 4-1 Activity Limits for Contents Type 1 - CT Solid in heavy tungsten insert - Design No 3982 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Activity Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
Ac-225 2.51E+00 6.78E+01 6.00E-03 417.95 2.10E+03 1.19E-03 3.46E-02 2.34E+00 B
30.00 8.68E+02 3.2105E+13 45 9.45E+16 2.51E+12 2.51E+12 S
Ac-227 7.24E-01 1.96E+01 9.00E-05 8049.19 2.70E+00 2.68E-01 4.72E-04 9.24E-03 B
30.00 6.35E+04 2.3513E+15 45 1.22E+14 7.24E+11 7.24E+11 S
Ac-228 4.28E-01 1.16E+01 5.00E-01 0.86 8.40E+04 5.09E-06 8.04E-03 9.30E-02 A
30.00 3.73E+03 1.3807E+14 45 3.78E+18 4.28E+11 4.28E+11 S
Am-241 3.58E+00 9.68E+01 1.00E-03 3581.11 1.30E-01 2.75E+01 3.28E-02 3.18E+00 B
30.00 9.14E+02 3.3828E+13 45 5.85E+12 3.58E+12 3.58E+12 S
As-77 7.90E+02 2.13E+04 7.00E-01 1128.38 3.90E+04 2.03E-02 1.41E-03 3.00E+01 B
30.00 2.13E+04 7.8987E+14 45 1.76E+18 9.43E+19 7.90E+14 H
Au-198 2.56E+02 6.92E+03 6.00E-01 426.50 9.00E+03 2.84E-02 4.34E-03 3.00E+01 B
30.00 6.92E+03 2.5590E+14 45 4.05E+17 6.99E+14 2.56E+14 H
Ba-131 1.88E+02 5.08E+03 2.00E+00 94.05 3.10E+03 6.07E-02 3.06E-03 1.55E+01 B
30.00 9.82E+03 3.6334E+14 45 1.40E+17 1.88E+14 1.88E+14 S
C-14 7.20E+00 1.95E+02 3.00E+00 2.40 1.60E-01 4.50E+01 2.93E-04 5.71E-02 B
30.00 1.02E+05 3.7850E+15 45 7.20E+12 6.92E+27 7.20E+12 M
Co-60 2.38E-01 6.44E+00 4.00E-01 0.60 4.20E+01 5.68E-03 1.54E-02 9.94E-02 A
30.00 1.95E+03 7.1970E+13 45 1.89E+15 2.38E+11 2.38E+11 S
Cs-131 6.71E+03 1.81E+05 3.00E+01 223.73 3.80E+03 1.77E+00 1.65E-04 3.00E+01 B
30.00 1.81E+05 6.7118E+15 45 1.71E+17 8.39E+35 6.71E+15 H
Cs-134 7.05E+00 1.90E+02 7.00E-01 10.07 4.80E+01 1.47E-01 1.02E-02 1.94E+00 B
30.00 2.95E+03 1.0905E+14 45 2.16E+15 7.05E+12 7.05E+12 S
Cs-137 1.44E+02 3.89E+03 6.00E-01 240.00 3.20E+00 4.50E+01 1.01E-03 3.94E+00 B
30.00 2.96E+04 1.0966E+15 45 1.44E+14 1.58E+15 1.44E+14 M
Cu-67 6.91E+02 1.87E+04 7.00E-01 986.75 2.80E+04 2.47E-02 1.61E-03 3.00E+01 B
30.00 1.87E+04 6.9073E+14 45 1.26E+18 6.50E+25 6.91E+14 H
Hg-203 3.57E+01 9.66E+02 1.00E+00 35.75 5.10E+02 7.01E-02 1.99E-03 1.92E+00 B
30.00 1.51E+04 5.5787E+14 45 2.30E+16 3.57E+13 3.57E+13 S
Ho-166 2.04E+00 5.52E+01 4.00E-01 5.10 2.60E+04 7.85E-05 4.29E-03 2.37E-01 B
30.00 6.99E+03 2.5852E+14 45 1.17E+18 2.04E+12 2.04E+12 S
I-125 3.19E+03 8.61E+04 3.00E+00 1062.52 6.40E+02 4.98E+00 3.48E-04 3.00E+01 B
30.00 8.61E+04 3.1875E+15 45 2.88E+16 4.49E+35 3.19E+15 H
I-129 2.93E-04 7.91E-03
< 1
< 1 6.50E-06 4.50E+01 4.68E-04 3.70E-06 B
30.00 6.41E+04 2.3720E+15 45 2.93E+08 3.31E+26 2.93E+08 M
I-131 3.28E+02 8.85E+03 7.00E-01 468.01 4.60E+03 7.12E-02 3.39E-03 3.00E+01 B
30.00 8.85E+03 3.2761E+14 45 2.07E+17 4.11E+15 3.28E+14 H
In-111 4.27E+02 1.15E+04 3.00E+00 142.34 1.50E+04 2.85E-02 2.60E-03 3.00E+01 B
30.00 1.15E+04 4.2702E+14 45 6.75E+17 1.45E+28 4.27E+14 H
Ir-192 1.81E+02 4.90E+03 6.00E-01 302.02 3.40E+02 5.33E-01 6.13E-03 3.00E+01 B
30.00 4.90E+03 1.8121E+14 45 1.53E+16 2.71E+15 1.81E+14 H
Ir-194 3.87E+01 1.04E+03 3.00E-01 128.87 3.10E+04 1.25E-03 5.35E-03 5.59E+00 B
30.00 5.61E+03 2.0766E+14 45 1.40E+18 3.87E+13 3.87E+13 S
Lu-177 1.03E+03 2.78E+04 7.00E-01 1470.30 4.10E+03 2.51E-01 1.08E-03 3.00E+01 B
30.00 2.78E+04 1.0292E+15 45 1.85E+17 1.56E+24 1.03E+15 H
Mo-99 5.27E+01 1.42E+03 6.00E-01 87.87 1.80E+04 2.93E-03 3.27E-03 4.66E+00 B
30.00 9.18E+03 3.3972E+14 45 8.10E+17 5.27E+13 5.27E+13 S
Na-24 2.63E-02 7.12E-01 2.00E-01 0.13 3.20E+05 8.23E-08 2.77E-02 1.97E-02 A
30.00 1.08E+03 4.0053E+13 45 1.44E+19 2.63E+10 2.63E+10 S
Np-237 1.17E-03 3.16E-02 2.00E-03 0.59 2.60E-05 4.50E+01 2.88E-02 9.10E-04 A
30.00 1.04E+03 3.8570E+13 45 1.17E+09 3.58E+12 1.17E+09 M
P-32 5.58E+00 1.51E+02 5.00E-01 11.15 1.10E+04 5.07E-04 4.12E-03 6.21E-01 B
30.00 7.28E+03 2.6946E+14 45 4.95E+17 5.58E+12 5.58E+12 S
P-33 2.44E+03 6.61E+04 1.00E+00 2444.45 5.80E+03 4.21E-01 4.54E-04 3.00E+01 B
30.00 6.61E+04 2.4444E+15 45 2.61E+17 5.10E+37 2.44E+15 H
Pb-203 5.20E+02 1.40E+04 3.00E+00 173.28 1.10E+04 4.73E-02 2.14E-03 3.00E+01 B
30.00 1.40E+04 5.1983E+14 45 4.95E+17 1.18E+17 5.20E+14 H
Pb-210 8.04E+00 2.17E+02 5.00E-02 160.79 2.80E+00 2.87E+00 2.31E-04 5.01E-02 B
30.00 1.30E+05 4.8135E+15 45 1.26E+14 8.04E+12 8.04E+12 S
Pd-109 2.96E+02 7.99E+03 5.00E-01 591.05 7.90E+04 3.74E-03 2.14E-03 1.71E+01 B
30.00 1.40E+04 5.1809E+14 45 3.56E+18 2.96E+14 2.96E+14 S
Ra-223 1.02E+01 2.75E+02 7.00E-03 1451.55 1.90E+03 5.35E-03 3.50E-02 9.60E+00 B
30.00 8.58E+02 3.1739E+13 45 8.55E+16 1.02E+13 1.02E+13 S
Ra-224 8.86E-02 2.40E+00 2.00E-02 4.43 5.90E+03 1.50E-05 3.37E-02 8.08E-02 B
30.00 8.90E+02 3.2924E+13 45 2.66E+17 8.86E+10 8.86E+10 S
Ra-226 1.02E-01 2.75E+00 3.00E-03 33.89 3.70E-02 2.75E+00 2.84E-02 7.80E-02 B
30.00 1.06E+03 3.9093E+13 45 1.67E+12 1.02E+11 1.02E+11 S
Re-186 1.56E+02 4.23E+03 6.00E-01 260.64 6.90E+03 2.27E-02 2.14E-03 9.04E+00 B
30.00 1.40E+04 5.1910E+14 45 3.11E+17 1.56E+14 1.56E+14 S
Re-188 1.22E+00 3.31E+01 4.00E-01 3.06 3.60E+04 3.40E-05 4.97E-03 1.64E-01 B
30.00 6.04E+03 2.2355E+14 45 1.62E+18 1.22E+12 1.22E+12 S
Rh-105 8.12E+02 2.19E+04 8.00E-01 1014.40 3.10E+04 2.62E-02 1.37E-03 3.00E+01 B
30.00 2.19E+04 8.1152E+14 45 1.40E+18 1.05E+31 8.12E+14 H
Se-75 4.61E+02 1.25E+04 3.00E+00 153.81 5.40E+02 8.55E-01 2.41E-03 3.00E+01 B
30.00 1.25E+04 4.6144E+14 45 2.43E+16 8.89E+18 4.61E+14 H
Sm-153 6.12E-01 1.65E+01 6.00E-01 1.02 1.60E+04 3.82E-05 1.94E-03 3.21E-02 B
30.00 1.54E+04 5.7134E+14 45 7.20E+17 6.12E+11 6.12E+11 S
Sr-89 1.22E+01 3.30E+02 6.00E-01 20.34 1.10E+03 1.11E-02 3.46E-03 1.14E+00 B
30.00 8.68E+03 3.2113E+14 45 4.95E+16 1.22E+13 1.22E+13 S
Sr-90 1.73E+00 4.67E+01 3.00E-01 5.76 5.10E+00 3.39E-01 3.46E-03 1.61E-01 B
30.00 8.68E+03 3.2113E+14 45 2.30E+14 1.73E+12 1.73E+12 S
Tb-161 1.61E+01 4.36E+02 2.00E-02 806.28 4.35E+03 3.71E-03 1.16E-03 5.06E-01 B
30.00 2.59E+04 9.5690E+14 45 1.96E+17 1.61E+13 1.61E+13 S
Th-227 1.01E+01 2.73E+02 5.00E-03 2020.21 1.10E+03 9.18E-03 3.59E-02 9.79E+00 B
30.00 8.36E+02 3.0947E+13 45 4.95E+16 1.01E+13 1.01E+13 S
Th-228 6.79E-02 1.84E+00 1.00E-03 67.95 3.00E+01 2.26E-03 3.21E-02 5.90E-02 B
30.00 9.33E+02 3.4537E+13 45 1.35E+15 6.79E+10 6.79E+10 S
Tl-201 1.45E+03 3.92E+04 4.00E+00 362.71 7.90E+03 1.84E-01 7.65E-04 3.00E+01 B
30.00 3.92E+04 1.4508E+15 45 3.56E+17 1.59E+22 1.45E+15 H
W-187 2.24E+01 6.06E+02 6.00E-01 37.36 2.60E+04 8.62E-04 4.54E-03 2.75E+00 B
30.00 6.61E+03 2.4460E+14 45 1.17E+18 2.24E+13 2.24E+13 S
W-188 1.23E+00 3.31E+01 3.00E-01 4.08 3.70E+02 3.31E-03 5.98E-04 1.98E-02 B
30.00 5.02E+04 1.8558E+15 45 1.67E+16 1.23E+12 1.23E+12 S
Y-90 1.73E+00 4.67E+01 3.00E-01 5.76 2.00E+04 8.63E-05 5.54E-03 2.59E-01 B
30.00 5.41E+03 2.0032E+14 45 9.00E+17 1.73E+12 1.73E+12 S
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 8 of 15 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Activity Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
Yb-169 4.42E+02 1.19E+04 1.00E+00 442.11 8.90E+02 4.97E-01 2.51E-03 3.00E+01 B
30.00 1.19E+04 4.4211E+14 45 4.01E+16 1.88E+19 4.42E+14 H
Yb-175 1.11E+03 2.99E+04 9.00E-01 1228.91 6.60E+03 1.68E-01 1.00E-03 3.00E+01 B
30.00 2.99E+04 1.1060E+15 45 2.97E+17 6.04E+23 1.11E+15 H
Max 6.71E+03 1.81E+05 8.05E+03 4.50E+01 3.00E+01 Column Colour codes 1
Identifies nuclide 2
Package activity limit for this Contents Type - from Col 17 Radionuclides 3
Calculated from Bq amount in Col 2 Package limit 4
A2 from 10CFR71 Physics data 5
- of A2's of nuclide at package activity limit Contents limit based on heat, mass or shielding 6
Specific activity from 10CFR71 7
Mass of nuclide at package activity limit 8
Heat generation rate of nuclide - from Microshield.
9 Heat output of nuclide at package activity limit 10 Package Type [A or B] based on individual nuclide limit 11 Mass limit of nuclide based on package heat limit 12 Calculated from limit in Col 11 13 Calculated from Bq amount in Col 12 14 Mass limit of nuclide based on capacity of insert 15 Calculated from Bq amount in Col 14 16 Package shielding limit from CTR2011/01 17 Package limit = least of heat, mass and shielding limits in Cols 13, 15 & 16 18 H shown where package limit is Heat limit 19 M shown where package limit is Mass limit 20 S shown where package limit is Shielding limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 9 of 15 Table 4-2 Activity Limits for Contents Type 2 - CT Solid in light tungsten insert - Design No 3985 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Act Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
Ac-225 1.09E+00 2.96E+01 6.00E-03 182.45 2.10E+03 5.21E-04 3.46E-02 1.02E+00 B
30.00 8.68E+02 3.2105E+13 345 7.25E+17 1.09E+12 1.09E+12 S
Ac-227 3.26E-01 8.81E+00 9.00E-05 3622.61 2.70E+00 1.21E-01 4.72E-04 4.16E-03 B
30.00 6.35E+04 2.3513E+15 345 9.32E+14 3.26E+11 3.26E+11 S
Ac-228 1.86E-01 5.03E+00 5.00E-01 0.37 8.40E+04 2.21E-06 8.04E-03 4.04E-02 A
30.00 3.73E+03 1.3807E+14 345 2.90E+19 1.86E+11 1.86E+11 S
Am-241 1.58E+00 4.28E+01 1.00E-03 1584.58 1.30E-01 1.22E+01 3.28E-02 1.41E+00 B
30.00 9.14E+02 3.3828E+13 345 4.49E+13 1.58E+12 1.58E+12 S
As-77 7.90E+02 2.13E+04 7.00E-01 1128.38 3.90E+04 2.03E-02 1.41E-03 3.00E+01 B
30.00 2.13E+04 7.8987E+14 345 1.35E+19 1.14E+19 7.90E+14 H
Au-198 2.43E+02 6.57E+03 6.00E-01 405.30 9.00E+03 2.70E-02 4.34E-03 2.85E+01 B
30.00 6.92E+03 2.5590E+14 345 3.11E+18 2.43E+14 2.43E+14 S
Ba-131 6.12E+01 1.65E+03 2.00E+00 30.60 3.10E+03 1.97E-02 3.06E-03 5.05E+00 B
30.00 9.82E+03 3.6334E+14 345 1.07E+18 6.12E+13 6.12E+13 S
C-14 5.52E+01 1.49E+03 3.00E+00 18.40 1.60E-01 3.45E+02 2.93E-04 4.38E-01 B
30.00 1.02E+05 3.7850E+15 345 5.52E+13 6.13E+27 5.52E+13 M
Co-60 9.37E-02 2.53E+00 4.00E-01 0.23 4.20E+01 2.23E-03 1.54E-02 3.91E-02 A
30.00 1.95E+03 7.1970E+13 345 1.45E+16 9.37E+10 9.37E+10 S
Cs-131 6.71E+03 1.81E+05 3.00E+01 223.73 3.80E+03 1.77E+00 1.65E-04 3.00E+01 B
30.00 1.81E+05 6.7118E+15 345 1.31E+18 7.43E+35 6.71E+15 H
Cs-134 2.63E+00 7.11E+01 7.00E-01 3.76 4.80E+01 5.48E-02 1.02E-02 7.24E-01 B
30.00 2.95E+03 1.0905E+14 345 1.66E+16 2.63E+12 2.63E+12 S
Cs-137 3.16E+02 8.55E+03 6.00E-01 527.06 3.20E+00 9.88E+01 1.01E-03 8.65E+00 B
30.00 2.96E+04 1.0966E+15 345 1.10E+15 3.16E+14 3.16E+14 S
Cu-67 6.91E+02 1.87E+04 7.00E-01 986.75 2.80E+04 2.47E-02 1.61E-03 3.00E+01 B
30.00 1.87E+04 6.9073E+14 345 9.66E+18 2.84E+24 6.91E+14 H
Hg-203 5.58E+02 1.51E+04 1.00E+00 557.87 5.10E+02 1.09E+00 1.99E-03 3.00E+01 B
30.00 1.51E+04 5.5787E+14 345 1.76E+17 5.32E+34 5.58E+14 H
Ho-166 9.20E-01 2.49E+01 4.00E-01 2.30 2.60E+04 3.54E-05 4.29E-03 1.07E-01 B
30.00 6.99E+03 2.5852E+14 345 8.97E+18 9.20E+11 9.20E+11 S
I-125 3.19E+03 8.61E+04 3.00E+00 1062.52 6.40E+02 4.98E+00 3.48E-04 3.00E+01 B
30.00 8.61E+04 3.1875E+15 345 2.21E+17 3.98E+35 3.19E+15 H
I-129 2.24E-03 6.06E-02
< 1
< 1 6.50E-06 3.45E+02 4.68E-04 2.84E-05 B
30.00 6.41E+04 2.3720E+15 345 2.24E+09 2.93E+26 2.24E+09 M
I-131 3.28E+02 8.85E+03 7.00E-01 468.01 4.60E+03 7.12E-02 3.39E-03 3.00E+01 B
30.00 8.85E+03 3.2761E+14 345 1.59E+18 9.94E+14 3.28E+14 H
In-111 4.27E+02 1.15E+04 3.00E+00 142.34 1.50E+04 2.85E-02 2.60E-03 3.00E+01 B
30.00 1.15E+04 4.2702E+14 345 5.18E+18 1.29E+28 4.27E+14 H
Ir-192 1.81E+02 4.90E+03 6.00E-01 302.02 3.40E+02 5.33E-01 6.13E-03 3.00E+01 B
30.00 4.90E+03 1.8121E+14 345 1.17E+17 7.19E+14 1.81E+14 H
Ir-194 1.47E+01 3.96E+02 3.00E-01 48.84 3.10E+04 4.73E-04 5.35E-03 2.12E+00 B
30.00 5.61E+03 2.0766E+14 345 1.07E+19 1.47E+13 1.47E+13 S
Lu-177 1.03E+03 2.78E+04 7.00E-01 1470.30 4.10E+03 2.51E-01 1.08E-03 3.00E+01 B
30.00 2.78E+04 1.0292E+15 345 1.41E+18 1.38E+24 1.03E+15 H
Mo-99 1.91E+01 5.17E+02 6.00E-01 31.85 1.80E+04 1.06E-03 3.27E-03 1.69E+00 B
30.00 9.18E+03 3.3972E+14 345 6.21E+18 1.91E+13 1.91E+13 S
Na-24 1.28E-02 3.45E-01 2.00E-01 0.06 3.20E+05 3.99E-08 2.77E-02 9.55E-03 A
30.00 1.08E+03 4.0053E+13 345 1.10E+20 1.28E+10 1.28E+10 S
Np-237 8.97E-03 2.42E-01 2.00E-03 4.49 2.60E-05 3.45E+02 2.88E-02 6.98E-03 B
30.00 1.04E+03 3.8570E+13 345 8.97E+09 1.58E+12 8.97E+09 M
P-32 2.49E+00 6.73E+01 5.00E-01 4.98 1.10E+04 2.26E-04 4.12E-03 2.77E-01 B
30.00 7.28E+03 2.6946E+14 345 3.80E+18 2.49E+12 2.49E+12 S
P-33 2.44E+03 6.61E+04 1.00E+00 2444.45 5.80E+03 4.21E-01 4.54E-04 3.00E+01 B
30.00 6.61E+04 2.4444E+15 345 2.00E+18 3.61E+37 2.44E+15 H
Pb-203 5.20E+02 1.40E+04 3.00E+00 173.28 1.10E+04 4.73E-02 2.14E-03 3.00E+01 B
30.00 1.40E+04 5.1983E+14 345 3.80E+18 2.45E+16 5.20E+14 H
Pb-210 3.31E+00 8.96E+01 5.00E-02 66.28 2.80E+00 1.18E+00 2.31E-04 2.07E-02 B
30.00 1.30E+05 4.8135E+15 345 9.66E+14 3.31E+12 3.31E+12 S
Pd-109 9.61E+01 2.60E+03 5.00E-01 192.26 7.90E+04 1.22E-03 2.14E-03 5.57E+00 B
30.00 1.40E+04 5.1809E+14 345 2.73E+19 9.61E+13 9.61E+13 S
Ra-223 4.14E+00 1.12E+02 7.00E-03 591.20 1.90E+03 2.18E-03 3.50E-02 3.91E+00 B
30.00 8.58E+02 3.1739E+13 345 6.56E+17 4.14E+12 4.14E+12 S
Ra-224 4.37E-02 1.18E+00 2.00E-02 2.18 5.90E+03 7.40E-06 3.37E-02 3.98E-02 B
30.00 8.90E+02 3.2924E+13 345 2.04E+18 4.37E+10 4.37E+10 S
Ra-226 4.80E-02 1.30E+00 3.00E-03 16.00 3.70E-02 1.30E+00 2.84E-02 3.68E-02 B
30.00 1.06E+03 3.9093E+13 345 1.28E+13 4.80E+10 4.80E+10 S
Re-186 5.31E+01 1.43E+03 6.00E-01 88.45 6.90E+03 7.69E-03 2.14E-03 3.07E+00 B
30.00 1.40E+04 5.1910E+14 345 2.38E+18 5.31E+13 5.31E+13 S
Re-188 5.67E-01 1.53E+01 4.00E-01 1.42 3.60E+04 1.57E-05 4.97E-03 7.60E-02 B
30.00 6.04E+03 2.2355E+14 345 1.24E+19 5.67E+11 5.67E+11 S
Rh-105 8.12E+02 2.19E+04 8.00E-01 1014.40 3.10E+04 2.62E-02 1.37E-03 3.00E+01 B
30.00 2.19E+04 8.1152E+14 345 1.07E+19 1.17E+29 8.12E+14 H
Se-75 4.61E+02 1.25E+04 3.00E+00 153.81 5.40E+02 8.55E-01 2.41E-03 3.00E+01 B
30.00 1.25E+04 4.6144E+14 345 1.86E+17 7.87E+18 4.61E+14 H
Sm-153 5.71E+02 1.54E+04 6.00E-01 952.23 1.60E+04 3.57E-02 1.94E-03 3.00E+01 B
30.00 1.54E+04 5.7134E+14 345 5.52E+18 1.91E+15 5.71E+14 H
Sr-89 5.17E+00 1.40E+02 6.00E-01 8.62 1.10E+03 4.70E-03 3.46E-03 4.83E-01 B
30.00 8.68E+03 3.2113E+14 345 3.80E+17 5.17E+12 5.17E+12 S
Sr-90 8.30E-01 2.24E+01 3.00E-01 2.77 5.10E+00 1.63E-01 3.46E-03 7.75E-02 B
30.00 8.68E+03 3.2113E+14 345 1.76E+15 8.30E+11 8.30E+11 S
Tb-161 7.39E+00 2.00E+02 2.00E-02 369.26 4.35E+03 1.70E-03 1.16E-03 2.32E-01 B
30.00 2.59E+04 9.5690E+14 345 1.50E+18 7.39E+12 7.39E+12 S
Th-227 4.17E+00 1.13E+02 5.00E-03 834.00 1.10E+03 3.79E-03 3.59E-02 4.04E+00 B
30.00 8.36E+02 3.0947E+13 345 3.80E+17 4.17E+12 4.17E+12 S
Th-228 3.35E-02 9.07E-01 1.00E-03 33.54 3.00E+01 1.12E-03 3.21E-02 2.91E-02 B
30.00 9.33E+02 3.4537E+13 345 1.04E+16 3.35E+10 3.35E+10 S
Tl-201 1.45E+03 3.92E+04 4.00E+00 362.71 7.90E+03 1.84E-01 7.65E-04 3.00E+01 B
30.00 3.92E+04 1.4508E+15 345 2.73E+18 1.41E+22 1.45E+15 H
W-187 8.56E+00 2.31E+02 6.00E-01 14.26 2.60E+04 3.29E-04 4.54E-03 1.05E+00 B
30.00 6.61E+03 2.4460E+14 345 8.97E+18 8.56E+12 8.56E+12 S
W-188 5.68E-01 1.53E+01 3.00E-01 1.89 3.70E+02 1.53E-03 5.98E-04 9.18E-03 B
30.00 5.02E+04 1.8558E+15 345 1.28E+17 5.68E+11 5.68E+11 S
Y-90 8.30E-01 2.24E+01 3.00E-01 2.77 2.00E+04 4.15E-05 5.54E-03 1.24E-01 B
30.00 5.41E+03 2.0032E+14 345 6.90E+18 8.30E+11 8.30E+11 S
Yb-169 4.42E+02 1.19E+04 1.00E+00 442.11 8.90E+02 4.97E-01 2.51E-03 3.00E+01 B
30.00 1.19E+04 4.4211E+14 345 3.07E+17 1.66E+19 4.42E+14 H
Yb-175 1.11E+03 2.99E+04 9.00E-01 1228.91 6.60E+03 1.68E-01 1.00E-03 3.00E+01 B
30.00 2.99E+04 1.1060E+15 345 2.28E+18 6.09E+22 1.11E+15 H
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 10 of 15 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Act Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
Max 6.71E+03 1.81E+05 3.62E+03 3.45E+02 3.00E+01 Column Colour codes 1
Identifies nuclide 2
Package activity limit for this Contents Type - from Col 17 Radionuclides 3
Calculated from Bq amount in Col 2 Package limit 4
A2 from 10CFR71 Physics data 5
- of A2's of nuclide at package activity limit Contents limit based on heat, mass or shielding 6
Specific activity from 10CFR71 7
Mass of nuclide at package activity limit 8
Heat generation rate of nuclide - from Microshield.
9 Heat output of nuclide at package activity limit 10 Package Type [A or B] based on individual nuclide limit 11 Mass limit of nuclide based on package heat limit 12 Calculated from limit in Col 11 13 Calculated from Bq amount in Col 12 14 Mass limit of nuclide based on capacity of insert 15 Calculated from Bq amount in Col 14 16 Package shielding limit from CTR2011/01 17 Package limit = least of heat, mass and shielding limits in Cols 13, 15 & 16 18 H shown where package limit is Heat limit 19 M shown where package limit is Mass limit 20 S shown where package limit is Shielding limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 11 of 15 Table 4-3 Activity Limits for Contents Type 3 - CT Gas in light tungsten insert - Design No 3985 Contents heat limit Contents mass limit Shielding limit Gas limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 16a 17 18 19 19a 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Act Act Mass Act Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq Bq H
M L
S Kr-79 2.30E+01 6.21E+02 2.00E+00 11.49 9.24E+04 2.49E-04 1.67E-03 1.04E+00 B
30.00 1.80E+04 6.6467E+14 345 3.19E+19 2.30E+13 3.07E+14 2.30E+13 S
Xe-133 1.04E+03 2.80E+04 1.00E+01 103.74 6.90E+03 1.50E-01 1.07E-03 3.00E+01 B
30.00 2.80E+04 1.0374E+15 345 2.38E+18 1.99E+33 6.97E+15 1.04E+15 H
Notes Column Colour codes 1
Identifies nuclide 2
Package activity limit for this Contents Type - from Col 17 Radionuclides 3
Calculated from Bq amount in Col 2 Package limit 4
A2 from 10CFR71 Physics data 5
- of A2's of nuclide at package activity limit Contents limit based on heat, mass or shielding 6
Specific activity from 10CFR71 7
Mass of nuclide at package activity limit 8
Heat generation rate of nuclide - from Microshield.
9 Heat output of nuclide at package activity limit 10 Package Type [A or B] based on individual nuclide limit 11 Mass limit of nuclide based on package heat limit 12 Calculated from limit in Col 11 13 Calculated from Bq amount in Col 12 14 Mass limit of nuclide based on capacity of insert 15 Calculated from Bq amount in Col 14 16 Package shielding limit from CTR2011/01 16a Gas Limit from CTR 2012/05 17 Package limit = least of heat, mass and shielding limits in Cols 13, 15 & 16 18 H shown where package limit is Heat limit 19 M shown where package limit is Mass limit 19a L Shown where package limit is gas leakage rate 20 S shown where package limit is Shielding limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 12 of 15 Table 4-4 Activity Limits for Contents Type 4 - CT Liquid in steel insert - Design No 3987 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output PackageType Heat output Act Act Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
I-131 7.40E+00 2.00E+02 7.00E-01 10.57 4.60E+03 1.61E-03 3.41E-03 6.82E-01 B
5.00 1.47E+03 5.4252E+13 905 4.16E+18 7.40E+12 7.40E+12 S
Column Colour codes 1
Identifies nuclide 2
Package activity limit for this Contents Type - from Col 17 Radionuclides 3
Calculated from Bq amount in Col 2 Package limit 4
A2 from 10CFR71 Physics data 5
- of A2's of nuclide at package activity limit Contents limit based on heat, mass or shielding 6
Specific activity from 10CFR71 7
Mass of nuclide at package activity limit 8
Heat generation rate of nuclide - from Microshield.
9 Heat output of nuclide at package activity limit 10 Package Type [A or B] based on individual nuclide limit 11 Mass limit of nuclide based on package heat limit 12 Calculated from limit in Col 11 13 Calculated from Bq amount in Col 12 14 Mass limit of nuclide based on capacity of insert 15 Calculated from Bq amount in Col 14 16 Package shielding limit from CTR2011/01 17 Package limit = least of heat, mass and shielding limits in Cols 13, 15 & 16 18 H shown where package limit is Heat limit 19 M shown where package limit is Mass limit 20 S shown where package limit is Shielding limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 13 of 15 Table 4-5 Activity Limits for Contents Type 5 - CT Liquid Mo-99 in a steel insert - Design No 4081 Contents heat limit Contents mass limit Shielding limit Package limit 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Nuclide Max Activity A2
- A2s Spec Ac Mass Heat gen Heat output Package Type Heat output Act Act Mass Act Act Act Code TBq Ci TBq TBq/g g
W/Ci W
A or B W
Ci Bq g
Bq Bq Bq H
M S
Mo-99 3.70E+01 1.00E+03 3.00E-01 123.33 3.10E+04 1.19E-03 3.43E-03 3.43E+00 B
5.00 1.46E+03 5.3901E+13 905 2.81E+19 3.70E+13 3.70E+13 S
Column Colour codes 1
Identifies nuclide 2
Package activity limit for this Contents Type - from Col 17 Radionuclides 3
Calculated from Bq amount in Col 2 Package limit 4
A2 from 10CFR71 Physics data 5
- of A2's of nuclide at package activity limit Contents limit based on heat, mass or shielding 6
Specific activity from 10CFR71 7
Mass of nuclide at package activity limit 8
Heat generation rate of nuclide - from Microshield.
9 Heat output of nuclide at package activity limit 10 Package Type [A or B] based on individual nuclide limit 11 Mass limit of nuclide based on package heat limit 12 Calculated from limit in Col 11 13 Calculated from Bq amount in Col 12 14 Mass limit of nuclide based on capacity of insert 15 Calculated from Bq amount in Col 14 16 Package shielding limit from CTR2011/01 17 Package limit = least of heat, mass and shielding limits in Cols 13, 15 & 16 18 H shown where package limit is Heat limit 19 M shown where package limit is Mass limit 20 S shown where package limit is Shielding limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 14 of 15 Table 4-6 Typical Activity for Contents Type 6 - CT Thorium Target in CV fitted with Shielding plug version b (no insert) 1 2
3 4
5 6
7 8
9 10 11 12 13 14 Nuclide Max Activity T 1/2 A2
- A2s Spec Ac Mass Heat gen Heat output Specific dose rate Dose rate for Activity Limit for gases Gas % of allowable TBq Ci hours TBq TBq/g g
W/Ci W
mSv/hr per Ci mSv/hr Ci Ac-225 6.90E-03 1.86E-01 2.40E+02 6.00E-03 1.15 2.15E+03 3.22E-06 3.46E-02 6.44E-03 1.38E-06 2.57E-07 Ac-226 5.39E-02 1.46E+00 2.90E+01 2.00E-02 2.69 1.77E+04 3.05E-06 2.52E-03 3.66E-03 5.41E-07 7.88E-07 Ac-228 1.56E-02 4.21E-01 6.15E+00 5.00E-01 0.03 8.26E+04 1.89E-07 7.81E-03 3.29E-03 3.62E-01 1.52E-01 Ag-111 7.13E-02 1.93E+00 1.79E+02 6.00E-01 0.12 5.84E+03 1.22E-05 2.25E-03 4.34E-03 5.87E-06 1.13E-05 Ag-112 2.47E-03 6.67E-02 3.13E+00 2.00E-02 0.12 3.30E+05 7.47E-09 1.21E-02 8.08E-04 7.18E-01 4.79E-02 Ag-113 2.79E-02 7.54E-01 5.37E+00 2.00E-02 1.39 1.91E+05 1.46E-07 4.94E-03 3.72E-03 6.73E-03 5.07E-03 Br-83 4.25E-04 1.15E-02 2.40E+00 2.00E-02 0.02 5.81E+05 7.30E-10 1.97E-03 2.26E-05 1.30E-06 1.49E-08 Cd-115 1.36E-01 3.67E+00 5.35E+01 4.00E-01 0.34 1.88E+04 7.21E-06 3.03E-03 1.11E-02 1.04E-05 3.82E-05 Cd-117 5.57E-04 1.50E-02 2.49E+00 2.00E-02 0.03 3.98E+05 1.40E-09 9.00E-03 1.35E-04 9.70E-01 1.46E-02 Ce-143 8.89E-02 2.40E+00 3.30E+01 6.00E-01 0.15 2.45E+04 3.63E-06 4.24E-03 1.02E-02 4.18E-03 1.00E-02 Cr-51 4.85E-02 1.31E+00 6.64E+02 3.00E+01 0.00 3.40E+03 1.43E-05 2.18E-04 2.86E-04 8.19E-16 1.07E-15 I-130 2.26E-02 6.10E-01 1.24E+01 2.00E-02 1.13 7.21E+04 3.13E-07 1.43E-02 8.74E-03 1.16E-01 7.08E-02 I-132 1.67E-04 4.51E-03 2.30E+00 4.00E-01 0.00 3.82E+05 4.36E-10 1.63E-02 7.37E-05 5.63E-01 2.54E-03 I-133 1.28E-01 3.45E+00 2.08E+01 6.00E-01 0.21 4.19E+04 3.05E-06 6.08E-03 2.10E-02 5.36E-02 1.85E-01 I-135 2.33E-02 6.30E-01 6.57E+00 6.00E-01 0.04 1.31E+05 1.79E-07 1.14E-02 7.20E-03 1.79E+00 1.13E+00 In-115m 4.71E-03 1.27E-01 4.49E+00 1.00E+00 0.00 2.25E+05 2.10E-08 2.00E-03 2.54E-04 3.36E-09 4.27E-10 In-117m 8.82E-05 2.38E-03 1.94E+00 2.00E-02 0.00 5.10E+05 1.73E-10 3.11E-03 7.42E-06 4.84E-05 1.15E-07 Kr-85m 1.05E-02 2.84E-01 4.48E+00 3.00E+00 0.00 3.04E+05 3.46E-08 2.44E-03 6.95E-04 9.02E-07 2.57E-07 55 0.52%
Kr-87 1.04E-06 2.80E-05 1.27E+00 2.00E-01 0.00 1.05E+06 9.89E-13 1.26E-02 3.52E-07 1.49E+00 4.17E-05 3.7 0.001%
Kr-88 1.44E-03 3.90E-02 2.84E+00 2.00E-02 0.07 4.63E+05 3.11E-09 1.38E-02 5.37E-04 4.72E+00 1.84E-01 3.8 1.03%
La-141 6.11E-03 1.65E-01 3.92E+00 2.00E-02 0.31 2.10E+05 2.92E-08 6.01E-03 9.93E-04 4.07E-02 6.72E-03 La-142 6.27E-06 1.69E-04 1.52E+00 2.00E-02 0.00 5.37E+05 1.17E-11 1.92E-02 3.26E-06 5.25E+00 8.90E-04 Mn-52 8.73E-02 2.36E+00 1.34E+02 3.00E-01 0.29 1.60E+04 5.46E-06 2.09E-02 4.93E-02 2.29E+00 5.40E+00 Mo-99 1.08E-01 2.93E+00 6.59E+01 6.00E-01 0.18 1.77E+04 6.11E-06 3.21E-03 9.40E-03 2.78E-03 8.14E-03 Nb-96 3.14E-02 8.47E-01 2.34E+01 2.00E-02 1.57 5.17E+04 6.07E-07 1.61E-02 1.36E-02 5.22E-01 4.42E-01 Pa-228 5.49E-02 1.48E+00 2.20E+01 2.00E-02 2.74 2.31E+04 2.38E-06 9.61E-03 1.43E-02 6.29E-01 9.33E-01 Pa-229 1.18E-01 3.18E+00 3.36E+01 2.00E-02 5.89 1.51E+04 7.83E-06 6.32E-04 2.01E-03 3.92E-02 1.25E-01 Pa-232 4.28E-02 1.16E+00 3.14E+01 2.00E-02 2.14 1.59E+04 2.69E-06 6.60E-03 7.63E-03 1.09E-01 1.26E-01 Pb-209 8.03E-04 2.17E-02 3.25E+00 2.00E-02 0.04 1.70E+05 4.71E-09 1.17E-03 2.54E-05 5.08E-03 1.10E-04 Pd-109 1.68E-01 4.55E+00 1.37E+01 5.00E-01 0.34 7.76E+04 2.17E-06 2.67E-03 1.21E-02 6.87E-06 3.12E-05 Pd-112 1.92E-01 5.20E+00 2.10E+01 2.00E-02 9.62 4.92E+04 3.91E-06 5.64E-04 2.93E-03 6.40E-03 3.33E-02 Pr-145 1.81E-02 4.90E-01 5.98E+00 2.00E-02 0.91 1.34E+05 1.36E-07 4.12E-03 2.02E-03 3.82E-03 1.87E-03 Rh-105 1.72E-01 4.64E+00 3.54E+01 8.00E-01 0.21 3.12E+04 5.51E-06 1.37E-03 6.35E-03 7.88E-11 3.66E-10 Ru-105 1.50E-02 4.06E-01 4.44E+00 6.00E-01 0.03 2.48E+05 6.05E-08 7.05E-03 2.86E-03 2.31E-02 9.38E-03 Sb-127 6.59E-02 1.78E+00 9.24E+01 2.00E-02 3.30 9.87E+03 6.68E-06 5.98E-03 1.07E-02 1.51E-02 2.69E-02 Sb-128 1.37E-02 3.70E-01 9.01E+00 2.00E-02 0.69 1.00E+05 1.36E-07 2.13E-02 7.89E-03 2.47E-01 9.15E-02 Sb-129 7.33E-03 1.98E-01 4.40E+00 2.00E-02 0.37 2.04E+05 3.59E-08 1.10E-02 2.18E-03 8.46E-01 1.68E-01 Sn-121 1.50E-01 4.06E+00 2.70E+01 2.00E-02 7.51 3.54E+04 4.24E-06 6.85E-04 2.78E-03 6.85E-02 2.78E-01 Sr-91 8.83E-02 2.39E+00 9.63E+00 3.00E-01 0.29 1.32E+05 6.68E-07 8.07E-03 1.93E-02 1.61E-01 3.84E-01 Sr-92 1.10E-03 2.97E-02 2.66E+00 3.00E-01 0.00 4.73E+05 2.32E-09 9.13E-03 2.71E-04 1.55E+00 4.60E-02 Tc-99m 8.24E-03 2.23E-01 6.01E+00 4.00E+00 0.00 1.95E+05 4.23E-08 8.46E-04 1.89E-04 2.21E-06 4.92E-07 Te-127 1.74E-02 4.70E-01 9.35E+00 7.00E-01 0.02 9.75E+04 1.78E-07 1.36E-03 6.39E-04 3.07E-09 1.44E-09 Te-132 7.54E-02 2.04E+00 7.69E+01 4.00E-01 0.19 1.14E+04 6.60E-06 2.05E-03 4.17E-03 8.52E-03 1.74E-02 Th-231 6.29E-01 1.70E+01 2.55E+01 2.00E-02 31.46 1.96E+04 3.20E-05 1.12E-03 1.91E-02 7.18E-05 1.22E-03 Xe-135 5.84E-02 1.58E+00 9.14E+00 2.00E+00 0.03 9.39E+04 6.23E-07 3.37E-03 5.33E-03 6.72E-05 1.06E-04 230 0.69%
Y-92 6.35E-03 1.72E-01 3.54E+00 2.00E-01 0.03 3.56E+05 1.78E-08 1.01E-02 1.73E-03 1.68E-01 2.88E-02 Y-93 1.01E-01 2.73E+00 1.02E+01 3.00E-01 0.34 1.22E+05 8.26E-07 7.52E-03 2.05E-02 1.32E-01 3.60E-01 Zr-97 1.09E-01 2.95E+00 1.69E+01 4.00E-01 0.27 7.10E+04 1.53E-06 9.49E-03 2.79E-02 1.26E-01 3.71E-01 Max 6.29E-01 1.70E+01 6.64E+02 3.00E+01 3.15E+01 3.20E-05 4.93E-02 Total 2.99E+00 8.08E+01 76.29 1.38E-04 3.29E-01 1.07E+01 2.231%
Notes Column 1
Identifies nuclide 2
Calculated from Ci amount in Col 3 3
Package activity limit for this Contents Type - calculated for proton irradiation for 0.2 Ci Ac-225 and 24H decay from EOB 4
Halflive taken from LANL MCNP output 5
A2 from 10CFR71 - value of 0.02 TBq used for unlisted nucides 6
- of A2's of each nuclide - Nuclides present at > A2 are shown in red.
7 Specific activity calculated using the formula provided in para 240.2 of IAEA SSG-26 8
Mass of nuclide at package activity limit 9
Heat generation rate of nuclide - from Microshield 10 Heat output of nuclide at package activity limit
Package Contents Specification PCS 038 for Safkeg-HS Issue F Package Design No 3977A Page 15 of 15 11 Specfic surface dose rate for each nuclide 12 Surface dose rate for each nuclide 13 Limit for gases based on calculated leakage rate of 10-6 A2/hr (CS 2018/01) 14 Package activity limit for gas in this Contents Type as % of allowable Colour codes Radionuclides Calc content Physics data Calculated values Dose rates Gas limits