ML19343A007

From kanterella
Jump to navigation Jump to search

Ctr 2008/11, Rev 17, SAFKEG-HS 3977A, Chapter 0, Sarp Status and Contents
ML19343A007
Person / Time
Site: 07109338
Issue date: 12/03/2019
From:
Croft Associates Limited
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML19343A003 List:
References
TAC L24678 CTR 2008/11, Rev 17
Download: ML19343A007 (10)


Text

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 1 CTR2008-11-R17-Sc0-v1.docx Safety Analysis Report Safkeg-HS Design No. 3977A Package Docket 71-9338 Application for Approval by the NRC Applicant: Croft Associates Limited

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 2 CTR2008-11-R17-Sc0-v1.docx CONTENTS 0 SARP STATUS AND CONTENTS......................................................................................... 0-2 0.1 SARP REVISION STATUS.............................................................................................. 0-3 0.2 SUPPORTING DOCUMENT REVISION STATUS....................................................... 0-4 0 SARP STATUS AND CONTENTS This Safety Analysis Report for Packaging (SARP) has been prepared by Croft Associates Ltd for the new approval of the SAFKEG-HS Design No. 3977A transport package as a Type B(U) design.

This section (Section 0) defines the document status and lists the contents of the SARP (SARP sections and appended documents included in the SARP).

This SARP is a controlled document under the Croft Associates Ltd Quality Assurance Program approved by the NRC under Approval Number 71-9338.

Revisions to the SARP are on a document control basis, with revisions at each update normally being indicated by a vertical change bar in the right hand margin.

Reference documents, which are listed in the Appendices to each section, are those available in the general literature and are not provided in the SARP.

Supporting documents are those developed specifically for the SARP and are provided in the section that is most closely associated with the document. These supporting documents are listed in this section, together with their revision status.

Document control for the supporting documents which have been produced by different organizations at different times with different styles, is established by reference designations and issue status and/or date: there is no significance in the various policies of adding the names of author, checker or approver or whether they are manually or electronically signed.

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 3 CTR2008-11-R17-Sc0-v1.docx 0.1 SARP REVISION STATUS Title SAFKEG-HS 3977A Docket No. 71-9338 Number CTR 2008/11 Issue Revision 17 File Reference CTR2008-11-R17-Sc0-v1.docx Compiled Checked A L Ferguson R A Vaughan Approved Date 03 December 2019 R A Vaughan Croft Associates Ltd F4 Culham Science Centre Abingdon Oxon OX14 3DB UK Tel 44 (0)1865 407740

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 4 CTR2008-11-R17-Sc0-v1.docx 0.2 SUPPORTING DOCUMENT REVISION STATUS Page/Document Reference Issue Status Title Section 0 - SUPPORTING DOCUMENT REVISION STATUS Pages 0-1 to 0-9 Rev 17 Section 1 - GENERAL INFORMATION Pages 1-1 to 1-47 Rev 17 Documents in Section 1.3 Appendix Documents in Section 1.3.2 Calculation Model Drawings 0C-5949 Issue A Safkeg-HS Construction 1C-5997 Issue A Containment Vessel HS Lid Construction 1C-5999 Issue A Containment Vessel HS Body Construction 3C-6850 Issue A HS-12x95-Tu Insert Design No. 3982 (construction) 3C-6851 Issue A HS-31x114-Tu Insert Design No. 3985 (construction) 3C-6852 Issue A HS-55x128-SS Insert Design No. 3987 (construction)

Documents in Section 1.3.3 Licensing Drawings Safkeg-HS Design No. 3977A Single Lid Version 1C-5940 Issue H Cover sheet for Safkeg-HS Design No. 3977A (licensing drawing) 0C-5941 Issue E Safkeg-HS Design No. 3977A (licensing drawing) 0C-5942 Issue C Keg Design No. 3977 (licensing drawing)

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 5 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title 0C-5943 Issue B Cork set for Safkeg-HS (licensing drawing) 1C-5944 Issue C Containment vessel Design No. 3978 (licensing drawing) 1C-5945 Issue D Containment vessel lid (licensing drawing) 1C-5946 Issue E Containment vessel body (licensing drawing) 2C-6173 Issue D HS-12x95-Tu Insert Design No 3982 (Licensing drawing) 2C-6174 Issue D HS-31x114-Tu Insert Design No 3985 (Licensing drawing) 2C-6176 Issue F HS-55x128-SS insert Design No 3987 (licensing drawing) 2C-6920 Issue A Silicone Sponge Rubber Disc Safkeg-HS Design No. 3977A Split Lid Mallinckrodt Version 1C-7500 Issue C Cover sheet for Safkeg-HS Design No. 3977A -

Mallinckrodt Version 0C-7501 Issue C Safkeg-HS Design No. 3977A - Mallinckrodt Version 0C-7502 Issue A Keg Design No. 3977 - Mallinckrodt Version 0C-7503 Issue A Cork set for Safkeg-HS - Mallinckrodt Version 1C-7504 Issue A CV Design No. 3978 - Mallinckrodt Version 1C-7505 Issue A CV lid - Mallinckrodt Version

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 6 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title 1C-7506 Issue A CV body - Mallinckrodt Version 1C-7507 Issue A Containment vessel plug - Mallinckrodt version 2C-7508 Issue C HS-50x85-SS insert Design No 4081 2C-7509 Issue B Snap Ring 2C-7510 Issue A Tungsten Liner Safkeg-HS Design No. 3977A Split Lid with Insert 4109 1C-7940 Issue C Cover sheet for Safkeg-HS Design No. 3977A 0C-7941 Issue C Safkeg-HS Design No. 3977A 0C-7942 Issue B Keg Design No. 3977 0C-7943 Issue B Cork set for Safkeg-HS 1C-7944 Issue C CV Design No. 3978 1C-7945 Issue B CV lid 1C-7946 Issue C CV body 1C-7947 Issue C Containment vessel plug 2C-8094 Issue B HS-55x113-ss SS insert Design No 4109

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 7 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title 2C-6920 Issue A Silicone Sponge Rubber Disc 1C-7975 Issue D Packing for Thorium Target in Design No. 3978 Documents in Section 1.3.4 Supporting Documents PCS 038 Issue K Package Contents Specification for Safkeg-HS -

Package Design No 3977A Section 2 - STRUCTURAL EVALUATION Pages 2-1 to 2-62 Rev 17 Documents in Section 2.12.2, Appendix CTR 2010/02 Issue A Prototype Safkeg-HS 3977A/0002 NCT and HAC Regulatory Test Report SERCO/TAS/002762/01 Issue 1 Compression Testing of Cork Vectra, L20008/1/R1 Rev 0B Stress Analysis of Safkeg HS 3977A Containment Vessel CS 2012/02 Issue A SAFKEG HS 3977A - Maximum Pressure in CV CS 2012/03 Issue A SAFKEG HS 3977A - Package Density Section 3 - THERMAL EVALUATION Pages 3-1 to 3-23 Rev 17 Documents in Section 3.5.2, Appendix AMEC/6335/001 Issue 1 Thermal Analysis of the Safkeg HS Design CS 2012/01 Issue A SAFKEG HS 3977A - Maximum Temperature of CV Inserts

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 8 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title CS 2016/31 Issue A Maximum Pressure in Containment Vessel 3978 Under NCT and HAC CS 2019-02 Issue A Safkeg-HS - Gas generated by radiolysis of moisture in the air ETR 426 Filename: 06 I131 MURR Report 23 Nov 13 Hydrogen Generation Analysis, MURR Technical Note ETR 427 Filename: 07 Hydrogen Ignition Review RAI 3_2 2 Apr 16 Analysis Of The Possibility Of, And Consequences From, Hydrogen Deflagration And Detonation Resulting From Radiolysis-Produced Hydrogen In An Iodine-131 Radiopharmaceutical Solution, MURR ETR 428 Filename: MURR Gas gen report 19 Jul 16 Additional Contents Request for Croft Packaging, MURR CS 2016/27 Issue A Temperature of Mo-99 Contents in the HS Package ETR 429 Filename: 06 Mo-99 Gas Generation v2-2 V2.2 Radiolytic Gas Formation in Mallinckrodt Produced Mo99 Solutions, Mallinckrodt Technical Report CS 2017/02 B

Maximum Pressure in Containment Vessel 3978 Under NCT and HAC with I-131 Contents Section 4 - CONTAINMENT Pages 4-1 to 4-11 Rev 17 Documents in Section 4.5.2, Appendix CS 2012/04 Issue A SAFKEG-HS 3977A - CV seal leak size for leaktight condition CS 2012/05 Issue A SAFKEG-HS 3977A - Gas contents limit for leaktight condition CS2018/01 Issue A SAFKEG-HS 3977A - Gas contents limit for leaktight condition - Thorium target Section 5 - SHIELDING EVALUATION

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 9 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title Pages 5-1 to 5-32 Rev 17 Documents in Section 5.5.2, Appendix CTR2011/01 Issue D SAFKEG HS 3977A: Package Activity Limits Based on Shielding CTR2013/09 Issue C Uncertainties Associated with the Proposed Shielding Calculation Method for the SAFKEG-HS 3977A Package AMEC/SF6652/001 Issue 2 Monte Carlo Modelling of Safkeg HS Container AMEC/CRM37327/TN_001 Issue 1 HS Container Shielding Assessment with I-131 AMEC/CRM37327/TN_001 Issue 1 HS Container Shielding Assessment with Mo-99 Atkins 5183326-HS-REP-001 01 Shielding Assessment of the 3977A SAFKEG Transport Package Type B(U) with Thorium Target Source Section 6 - CRITICALITY EVALUATION Page 6-1 Rev 17 Documents in Section 6.9, Appendix None Section 7 - OPERATING PROCEDURES Pages 7-1 to 7-16 Rev 17 Documents in Section 7.5, Appendix None Section 8-ACCEPTANCE TESTS AND MAINTENANCE PROGRAM Pages 8-1 to 8-14 Rev 17 Documents in Section 8.3, Appendix

SAFKEG-HS 3977A Docket No. 71-9338 CTR 2008/11, Rev 17 Page 0 - 10 CTR2008-11-R17-Sc0-v1.docx Page/Document Reference Issue Status Title None

-