ML18094A550

From kanterella
Jump to navigation Jump to search
Forwards Safety Insp Rept 50-272/89-17 on 890522-26 & Notice of Violation.Insp Conducted to Review Loss of RHR Sys Event on 890520 Due to Inadvertent Injection of Nitrogen from One Accumulator
ML18094A550
Person / Time
Site: Salem 
Issue date: 07/03/1989
From: Boger B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Miltenberger S
Public Service Enterprise Group
Shared Package
ML18094A551 List:
References
GL-88-17, NUDOCS 8907110235
Download: ML18094A550 (2)


See also: IR 05000272/1989017

Text

JUL o 3 1989

Docket Nos. 50-272

Public Service Electric and Gas Company

ATTN:

Mr. Steven E. Miltenberger

Vice President and

Chief Nuclear Officer

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

Gentlemen:

Subject:

Inspection Report Nos. 50-272/89-17

This letter refers to the special safety inspection conducted to review the

Joss of Residual Heat Removal Systems (RHR) event on May 20, 1989 due to

inadvertent injection of nitrogen from one of the accumulators and your actions

to respond to this event.

The inspection was conducted by a team led by

Dr. P. K. Eapen of this office on May 22-26, 1989, at Salem Unit 1, Lower

Alloways Township, New Jersey.

A discussion of our findings was held by

Dr. Eapen with you at the conclusion of this inspection.

Areas examined during this inspection are described in the NRC Region I

Inspection Report which is enclosed with this letter. Within these areas, the

inspection consisted of selective examinations of procedures and representative

records, interviews with plant staff, and observations by the inspectors.

We note that certain operator actions during this event were inappropriate.

These inappropriate.actions included:

the initial operator error of unblocking

the wrong valve from the back panel, and the operator action to drain the

Reactor Coolant System (RCS) when the pressurizer level went off scale high

without realizing that the RCS may be nitrogen bound.

Further, the initial

engineering evaluation did not adequately address the event.

We also noted that the operator training you provided in response to NRC Generic

Letter 88-17, Loss of Decay Heat Removal, was beneficial to the operator while

venting the RHR System when* it was gas bound.

Based on the results of this inspection, it appears that two activities were

not conducte.d in full compliance with NRC requirements, as set forth in the

Notice of Violation, enclosed herewith as Appendix A.

These violations have

been categorized by severity_ 1eve1 in accordance with the "Genera 1 Statement of

Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C

(Enf6rcement Policy).

You are required to respond to this letter and in

preparing your responsi, you should follow the instructions in Appendix A .

8907110235 890703

PDR

ADOCK 05000272

Q

PNU

OFFICIAL RECORD COPY

~*-**.;

PKl - 0001.0.0

06/27/89

TE"OI

JUL O 3 _198a

Public Service Electric

2

and Gas Company

The responses directed by this letter and the accompanying Notice are not

subject to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL-511.

Your cooperation with us in this matter is appreciated.

Sincerely,

Original Sig:1ed Br:.

Bruce A. Boger, Acting Director

Division of Reactor Safety

Enclosures:

1. NRC Region I Inspection Report

2.* Appendix A, Notice of Violation

cc w/encl:

Jack Urban, General Manager, Fuels Department, Delmarva Power & Light Co.

L. K. Miller, General Manager - Salem Operations

B. A. Preston, Manager, Licensing and Regulation

M. J. Wetterhahn, Esquire

General MaAager - Nuclear Safety Re~iew

R. Frylir:i.g, Jr., Esquire

Scott B. Ungerer, Manager, Joint Generation Projects Department,

Atlantic Electric Company

Licensing ~reject Manager, NRR

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

bee w/encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

DRP Section Chief

Robert J. Bores, DRSS

J. Dyer,. EDD

g

RI:DRS,L ..

EapenT'"'

6/J:>789

53

RI:DRS

Durr

6.t;is189

OFFICIAL RECORD COPY

PKl - 0002.0.0