ML18092B061

From kanterella
Jump to navigation Jump to search
Forwards Safety Insp Repts 50-272/86-05 & 50-311/86-05 on 860224-28 & Notices of Violation & Deviation.Unresolved Item Noted Re Radiological Controls of Handling & Preparation of RCS Demineralizer Resins for Disposal
ML18092B061
Person / Time
Site: Salem  
Issue date: 03/24/1986
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Corbin McNeil
Public Service Enterprise Group
Shared Package
ML18092B062 List:
References
NUDOCS 8603270295
Download: ML18092B061 (2)


See also: IR 05000272/1986005

Text

.

'~

Docket Nos. 50-272~~!£J-0!5

50-311

Public Service Electric and Gas Company

ATTN:

Mr. Corbin McNeill

Vice President - Nuclear

P.O. Box 236

Hancock 1 s Bridge, New Jersey 08038

Gentlemen:

MAR 2 4 1986

Subject:

Combined Inspection Nos. 50-272/86-05; 50-311/86-05

A routine safety inspection of your solid radioactive waste preparation,

packaging and shipping program was condu.cted by Mr. H. Bi cehouse of this

office on February 24-28, 1986 of activities authorized by NRC License Nos.

DPR-70 and DPR-75.

Our findings were discussed with Mr. J. Zupko and others

of your staff at the conclusion of the inspection on February 28, 1986.

The areas examined during this inspection are described in the NRC Region I

Inspection Report which is enclosed with this letter.

Within these areas, the

inspection consisted of selective examination of procedures and representative

records, interviews with personnel and observations by the inspector.

We also

reviewed your actions taken in response to previously identified items.

Within the scope of this review, it appears that one of your activities was

not conducted in full compliance with NRC requirements, as set forth in the

Notice of Violation, enclosed herewith as Appendix A.

This violation has

categorized by severity level in accordance with the revised NRC Enforcement

Policy (10 CFR 2, Appendix C) published in the Federal Register Notice (47

FR 9987) dated March 8, 1984.

You are required to respond to this. letter and

in preparing your response, you should follow the instructions in Appendix A.

The violation involved failure to verify that packaging had been leak tested

for a shipping container used under a general license.

Another activity appears to be a deviation from your commitment to IE Bulletin

No. 79-19,

11 Packaging Of Low-Level Radioactive Waste For Transport and

Burial 11 *

This deviation involves failure to train two quality control

inspectors involved in preparing radioactive waste for transport.

You are

requested to respond to this deviation and in preparing your response, you

should follow the instructions in Appendix B.

An unresolved item related to the radiological controls associated with the

handling and preparation of primary reactor coolant system demineralizer

resins for disposal was also noted.

We are concerned over the potential for

serious radiation exposures to personnel associated with handling the resin

particularly during dewatering verification and high integrity lid placement

CIR SALEM 86-05 - 0001.0.0

03/20/86

\\

Pub 1 i c Serv.i ce Electric

and Gas Company

2

operations.

We are also concerned over the possibility of spills of the

highly-contaminated resin which could result in serious airborne radioactivity

concentrations and unmonitored release to the environs.

Your cooperation with us in this matter is appreciated.

Sincerely,

Original Signed B":n

~~~~r~

/}~ion

of Radiation Safety

1

and Safeguards

I

Enclosures:

(1) Appendix A, Notice of Violation

(2) Appendix B, Notice of Deviation

(3)

NRC Region I Combined Inspection Report Numbers 50-272/86-05

and 50-311/86-05

cc w/encl:

R. L. Mittl, General Manager - Nuclear Assurance and Regulation

J.M. Zupko, Jr., General Manager - Salem Operations

E. A. Liden, Manager - Nuclear Licensing and Regulation

C. P. Johnson, Manager - Quality Assurance Nuclear Operations

General Manager - Nuclear Safety Review

A. J. Pietrofitta, General Manager, Power Production Engineering, Atlantic

Electric

M. J. Wetterhahn, Esquire

R. Fryling, Jr., Esquire

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

bee w/encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

DRP Section Chief

'}\\~\\\\~

RI:bRSS

H. Bicehouse/rw

3/1..\\ /86

R~/~

RI~S

W. Pasciak

R. Bellamy

3/vi'\\,/86

3/~6(/86

OFFICIAL RECORD COPY

CIR SALEM 86-05 - 0002.0.0

03/20/86