Attachment 3 - Proposed Technical Specification Changes (Mark-Up)
ML18068A689
Person / Time
Site: Callaway 
(NPF-030)
Issue date: 03/09/2018
From:
Ameren Missouri, Union Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18068A685 List:
References
ULNRC-06401, CAC MF8118, CAC MF8119
Download: ML18068A689 (6)


Text

Attachment 3 to U LNRC-0640 1 Page 1 of6 ATTACHMENT III PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)

Callaway Plant Amendment No. XX to ULNRC-0640 I Page 2 of 6 TABLE OF CONTENTS 3.7 PLANT SYSTEMS 3.7-I 3.7.1 Main Steam Safet Valves (MSSVs) 3.7-1 3.7.2 Main Steam Isolation Valves (MSJVs) and MSIV Bypass Valves 3.7-5 3.7.3 Main Feedwater Isolation Valves (MFIVs) and Main Feedwater Regulating Valves (MFRVs) and MFRV Bypass Valves 3.7-9 3.7.4 Atmospheric Relief Valves (ARVs) 3.7-13 3.7.5 Auxiliary Feedwater (AFW) S stem 3.7-15 3.7.6 Condensate Storage Tank (CST) 3.7-18 3.7.7 Component Cooling Water (CCW) System 3.7-20 3.7.8 Essential Service Water System (ESW) 3.7-22 3.7.9 Ultimate Heat Sink (UHS) 3.7-24 3.7.10 Control Room Emergency Ventilation System (CREVS) 3.7-26 3.7.11 Control Room Air Conditioning System (CRACS) 3.7-29 3.7.12 Emergency Core Cooling System (ECCS) Ptimp Room Exhaust Air Cleanup System

- Not Used 3.7-32 3.7.13 Emergency Exhaust System (EES) 3.7-33 3.7.14 Penetration Room Exhaust Air Cleanup System (PREACS)

Not Used 3.7-37 3.7.15 Fuel Storage Pool Water Level 3.7-38 3.7.16 fuel Storage Pool Boron Concentration 3.7-39 3.7.17 Spent Ftiel Assembly Storage 3.7-41 3.7.18 Secondary Specific Activity 3.7-43 3.7.19 Secondary System Isolation Valves (SSIVs) 3.7-44 13.7.20 Class 1E Electrical Equipment Air Conditioning (A/C) System 3.7-46 3.8 ELECTRICAL POWER SYSTEMS 3.8-I 3.8.1 AC Sources - Operating 3.8-I 3.8.2 AC Sources

- Shutdown 3.8-18 3.8.3 Diesel Fuel Oil. Ltibe Oil, and Stalling Air 3.8-21 3.8.4 DC Sources

- Operating 3.8-24 3.8.5 DC Sotirces

- Shutdown 3.8-28 3.8.6 Battery Cell Parameters 3.8-3 0 3.8.7 Invetlers

- Operating 3.8-34 3.8.8 Inveiiers

- Shutdown 3.8-35 3.8.9 Distribution Systems

- Operating 3.8-37 3.8.10 Distribtition Systems

- Shutdown 3.8-39 3.9 REFUELING OPERATIONS 3.9-1 3.9.1 Boron Concentration 3.9-1 3.9.2 Unborated Water Sotirce Isolation Valves 3.9-2 3.9.3 Nuclear Instrumentation 3.9-3 3.9.4 Containment Penetrations 3.9-5 3.9.5 Residual Heat Removal (RHR) and Coolant Circulation ugh Water Level 3.9-7 3.9.6 Residtial Heat Removal (RHR) and Coolant Circulation

- Low Water Level 3.9-9 Callaway Plant Amendment No. XX to ULNRC-06401 Page 3 of 6 3.7 PLANT SYSTEMS 3.7.20 Class I E Electrical Equiptiient Air Conditioning (A/C) System LCO 3.7.20 Two Class I E electrical equipment A/C trains shall be OPERABLE.

APPLICABILITY:

MODES 1. 2. 3. and 4.

ACTIONS CONDITION REQUIRED ACTtON COMPLETION TIME A.

One Class I E electrical A. I Initiate action to Immediately equipment A/C train implement mitigating inoperable, actions.

AND 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> A.2 Verify room area temperatures 90°F.

.ND Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> thereafter AND A.3 Restore Class I E electrical equipment A/C 30 das train to OPERABLE status.

B.

Required Action and B.I Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A not AND met.

B.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> C.

Two Class IE electrical C.1 Enter LCO 3.0.3.

Immediately equipment A/C trains inoperable.

(contin ned)

Callaway Plant Amendment No. XX to LJLNRC-0640 I Page 4 of 6 SURVEILLANCE_REQUIREMENTS SURVEILLANCE FREQUENCY In accordance ith SR 3.7.20.1 Verify each Class IE electrical equipment A/C train the Stirveillance actuates on an acttial or simulated actuation signal.

Frequency Control Program SR 3.7.20.2 Verify each Class I E electrical equipment A/C train has In accordance with the capability to remove the assumed heat load, the Surveillance Frequency Control Program Callaway Plant Amendment No. XX to ULNRC-06401 Page 5 of 6 Programs and Manuals 5.5 Ptograms and Manuals 5.5.11 Ventilation Filter Testing Program (VFTP) (continued) e.

Demonstrate at least once per 1 $ months that the heaters for each of the ESF systems dissipate the value specified below when tested in accordance with ANSI 510-1975 and corrected to design nameplate voltage settings.

5+/-1 ESF Ventilation System Control Room Pressurization Emergency Exhaust System The provisions of SR 3.0.2 and SR 3.0.3 are applicable to the VFTP test frequencies.

5.5.12 Explosive Gas and Storage Tank Radioactivity Monitoring Program This program provides controls for potentially explosive gas mixtures contained in the Gaseous Radwaste System, the quantity of radioactivity contained in gas storage tanks and the quantity of radioactivity contained in unprotected outdoor liquid storage tanks. The gaseous radioactivity quantities shall be determined following the methodology in Branch Technical Position (BTP) ETSB 11-5, Postulated Radioactive Release due to Waste Gas System Leak or Failure.

Revision 0. The tiquid radwaste quantities shall be determined in accordance with Standard Review Plan, Section 15.7.3. Postulated Radioactive Release due to Tank Failures. Revision 2.

The program shall include:

a.

The limits for concentrations of hydrogen and oxygen in the Gaseous Radwaste System and a surveillance program to ensure the limits are maintained. Such limits shall be appropriate to the systems design criteria (i.e.. whether or not the system is designed to withstand a hydrogen explosion);

b.

b. A surveilLance program to ensure that the quantity of radioactivity contained in each gas storage tank is less than the amount that would result in a whole body exposure of 0.5 rem to any individual in an unrestricted area, in the event of an uncontrolled reLease of the tanks contents; and Wattage Callaway Plant Amendment No. XX to ULNRC-0640 I Page 6 of 6 c.

A surveillance program to ensure that the quantity of radioactivity contained in the outdoor liquid radwaste tanks listed below that are not (continued)

CALLAWAY PLANT 5.0-16 Amendment No. 215 Callaway Plant Amendment No. XX