ENCLOSURE D CONSUMERS ENERGY COMPANY PALISADES PLANT DOCKET 50-255 PALISADES NUCLEAR PLANT 1996 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERA TING REPORT 1996 PALISADES FINAL MONTHLY PROGRESS REPORT 60 Pages

~'TELEDYNE FINAL MONTHLY PROGRFSS REPORT TO CONSUMERS POWER COMP ANY JACKSON, MICHIGAN Brown Engineering Environmental Services MIDWEST LABORATORY 700 L\\NOWEHR ROAD NORniBllOOIC. IUJNOIS 60062-2310 (141) 56'-0700 FAX (9C7) 5'M517 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

FOR PALISADFS NUCLEAR GENERA TING PLANT PREPARED AND SUBMITIED BY TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES MIDWEST LABORATORY Project Number: 8022 Reporting Period: January - December, 1996 Reviewed and Approved by ----l--~~

Distribu~~n: M. Grogan (1 copy)

PALISADES TABLE OF CONTENTS Sectiori

~

List of Tables.....................................................................................................iii

1.0 INTRODUCTION

.............................................................................................. iv 2.0 LISTING OF MISSED SAMPLES.......................................................................... v Appendices A

Interlaboratory Comparison Program Results.................................................... A-1 B

Data Reporting Conventions............................................................................. B-1 ii.

PALISADES LIST OF TABLES 1

Airborne Particulates and Iodine-131 Location lST............................................................................................ 1-1 Location 21H........................................................................................... 1-2 Location 3HS........................................................................................... 1-3 Location 4JS................................... *.............. :........................................... 1-4 Location 5PR.:.......................................................................................... 1-5 Location 6RB............................................................................................ l-6 Location 750............................................................................................ 1-7 Location 8SP............................................................................................ 1-8 Location 9TP............................................................................................. 1-9 Location lOGR.......................................................................................... 1-10 Location 1 lKZ........................................................................................... 1-11 Location 12DG.......................................................................................... l-12 2

Gamma Radiation, as Measured by TLDs, Monthly Exposure................................. 2-1 3

Gamma Radiation, as Measured by TLDs, Quarterly Exposure.............................. 3-1 4

Gamma Radiation, as Measured by TLDs, Annual Exposure....................................4-1 5

  • 6 Lake Water, Intake and Discharge......................................................................... 5-1 Drinking Lake Water........................................................................................... 6:1 7

Well -Water................................................................................... :..................... 7-1 8

Water, Ludington controls............................................................ :................ ~....... 8.1 9

In-Plant Water.................................................................................................... 9-1 10 Milk..................................................................................... *............................. 10-1 11 Food Crops......................................................................................................... 11-1 12 Fish...................... ;........... ;..............................................,................................. 12-1 13 Algae............................................................. ;................................ :.................. 13-1 14 Bottom Sediments...................................................... ;....................................... 14-1 15 Special Samples 15.1 Liquid Radwaste..................................................................................... 15.1-1 15.2 Stack Filters............................... ;.......................................................... 15.2-1 15.3 NRC Split Samples................................................................................ 15.3-1 15.4 Reactor Water....................................................................................... 15.4-1 15.5 Steam Generator Slowdown.................................................................... 15.5-1 iii

PALISADES

1.0 INTRODUCTION

The following constitutes the current Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Consumers Power Company, Palisades Nuclear Generating Plant.

Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are ~ot yet completed.

Data obtained in the program are well within the ranges previously encounted in the program and to be expected in the environmental media sampled.

For all gamma isotopic analyses, spectrum is computer scanned from 80 to 2048 KeV. Speicifically included are Mn-54, Fe-59, Co-58, Ccr60, Zn-65, Zr-95, Nb-95, 1-131, Ba-La-140, Cs-134 and Cs-137.

Naturally-occuring gamma-errlitters, such as K-40 and Ra daughters, are frequently detected but not listed here. Data listed as"<" are at the 4.66 sigma level, others are 2 sigma.

All concentrations, except gross beta, are decay corrected the time of collection.

All samples were collected within the scheduled period Wlless noted otherwise in the Listing of Missed Samples.

iv

PALISADES 2.01.IS'I1NG OF MISSED SAMPLES Expected Collection Sample Type Location Date Reason RW PALISADES 01-31-96 Sample not received.

RW PALISADES 0'2-29-96 Sample not received.

RW PALISADES 03-31-96 Sample not received.

RW*

PALISADES 05-31-96 Sample not received.

TLD ST-11 06-02-96 TLD lost in the field.

RW PALISADES 06-30-96 Sample not received.

RW PALISADES 09-30-96 Sample not received.

RW PALISADES 10-31-96 Sample not received.

SP PALISADES 10-31-96 Sample not received.

RW PALISADES 11-30-96 Sample not received.

RW PALISADES 12-31-96 Sample not received.

v

PALISADES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

lST - Palisades Units:

pCl/m1 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~ml~

Gross Beta Iodine-131 Collected (m1)

Gross Beta lodine-131 Required LLD WU OJml

.QJll WlZQ 01-08-96 300 0.028+/-0.003

<0.007 (YJ--08-96 314 0.022 +/- 0.003

< 0.010 01-15-96 340 0.027+/-0.003

< 0.013 07-15-96 30'J 0.021 +/- 0.003

< 0.009 01-22-96 334 0.024+/-0.003

<0.007 (YJ-22-96 323 0.019 +/- 0.003

<0.015 01-29-96 343 0.026+/-0.003

<0.011 07-29-96 300 0.022 +/- 0.003

< 0.013 02-05-96 357 0.024+/-0.003

< 0.011 08-05-96 314 0.014 +/- 0.003

<: 0.012 02-12-96 340 0.023 +/-0.003

<0.008 08-12-96 314 0.022 +/-.0.003

< 0.014 02-19-96 343 0.019+/-0.003

<0.012 08-19-96 317 0.023 +/- 0.003

< 0.012 02-26-96 340 0.018+/-0.003

<0.013 08-26-96 317 0.Q30 +/- 0.003

< 0.010 03-04-96 346 0.024+/-0.003

<0.007 09-03-96 363 0.027 +/- 0.003

< 0.014 03-11-96 343 0.021 +/- 0.003

<0.016 09-09-96 272 0.00 +/-0.004

< 0.010 03-18-96 337 0.026 +/- 0.003

<0.014 09-16-96 323 0.021 +/- 0.003

<0.009 03-25-96 340 O.O'l3* +/- 0.003

< 0.013 09-23-96 326 0.025 +/- 0.003

<0.008 04-01-96 346 0.022 +/- 0.003* <0.014 09-3()..96 326 0.020 +/- 0.003

< 0.014 1st Quarter Mean:t:s.d. 0.024 +/- 0.003

< 0.016 3rd Quarter Mean:t:s.d. 0.024 +/- 0.007

< 0.015 04-08-96 334 O.O'l3 +/- 0.003

<0.014 lo-al-96.

323 0.029 +/- 0.003

< 0.013 04-15-96 337 0.020 +/- 0.003

< 0.015 10-14-96 326 0.020 +/- 0.003

< 0.015 04-22-96 326 0.016 +/- 0.003

<0.007 10-21-96 326 0.024 +/- 0.003

< 0.009 04-29-96 329 0.014 +/- 0.003

< 0.015 10-28-96 326 0.026 +/- 0.003

< 0.010 05-06-96 331 0.018 +/- 0.003

< 0.005 11-0f.96 334 0.024 +/- 0.003

< 0.011 05-13-96 331 0.018 +/- 0.003

< 0.007 11-10-96 278 0.022 +/- 0.003

< 0.014 05-20-96 3()1) 0.021 +/- 0.003

< 0.005 11-17-96 331 0.016 +/- 0.003

< 0.015 05-28-96 382 0.015 +/- 0.002

<0.015 11-24-96 329 0.020 +/- 0.003

< 0.016 06-03-96 266 0.019 +/- 0.003

<0.020 12-01-96 329 0.024 +/- 0.003

< 0.006 06-1()..96 275 0.013 +/- 0.003

< 0.015 12-08-96 329 0.0'28 +/- 0.003

< 0.014 06-17-96 351 0.016 +/- 0.002

< 0.012 12-16-96 3'17 0.025 +/- 0.003

< 0.044 06-24-96 312 0.016 +/- 0.003

<0.012 12-23-96 340 0.029 +/- 0.003

< 0.007 07-01-96 3()1) 0.021 +/- 0.003

<0.008 12-30-96 346 0.026 +/- 0.003

< 0.012 2nd Quarter Mean+/-s.d. 0.018 +/- 0.003

< 0.0'20 4th Quarter Mean+/-s.d. 0.0'24 +/- 0.004

'< 0.044 Cumulative Average:

0.022 Previous Annual Average:

0.022 1-1

PALISADES Table 1.

Airborne particulates and cha.rcoal canisters, analyses for gross beta and iodine-131.

Location:

21lf - Coloma (5 miles SSE)

Units:

pO/mJ Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~mJ Gross Beta Iodine-131 Collected

~mJi Gross Beta Iodine-131 Reqµired I.LP OJll OJlZil il.!21 Jl.OZQ 01-08-96 320 0.0'28 :t 0.000

<0.008 07-08-96 323 0.023 :t 0.003

< 0.010 01-15-96 351 0.0'29 +/- 0.000

<0.014 07-15-96 320 0.0'20 :t 0.003

< 0.009 01-22-96 348 0.023+/-0.000

< 0.00'7 07-22-96 3.31 0.019 +/- 0.003

< 0.016 01-29-96 360 0.024 +/- 0.003

< 0.011 07-29-96

.312 0.018 +/- 0.003 < 0.014 02-05-96 385 0.0'28 +/- 0.000

< 0.012 08-05-96 320 0.018 +/- 0.003

< 0.013 02-12-96 346:

0.021+/-0.000 <0.<Q 08-12-96 326 0.023 +/- 0.003

< 0.014 02-19-96 36.1 0.019+/-0.000

< 0.013 08-19-96 326 0.0'27 +/- 0.003

< 0.012 02-26-96 351 0.011+/-0.000

< 0.013 08-26-96 326 0.000 :t 0.003.

< 0.010 03-0&-96 36.1 0.024 +/- 0.003

< 0.00'7 09-03-96 371 0.000 :t 0.003

<0.015 03-11-96 36.1 0.023 :t 0.003

< 0.016 09-09-96 278 0.045 +/- O.OOoi

< 0.011 03-18-96 351.

0.0'24 +/- 0.000

<0.014 09-16-96 3.3' 0.0'22 +/- 0.003

< 0.009 03-25-96 354 0.0'21 :t 0.000

<0.014 09-23-96 3.37 0.023 :t 0.003

< 0.(0J 04-01-96 360 0.020+/-0.000

<0.014 09-30-96 340 0.0'22 +/- 0.003

< 0.015 1st Quarter Mean+/-s.d. 0.024 +/- 0.004

<0.016 3rd Quarter Meants.d.

  • 0.025 +/- 0.007

< 0.016 04-08-96 348 0.024 :t 0.003

<0.014 1()-07-96 3.37 0.0'27 :t 0.003

< 0.013 04-15-96 351 0.018 :t 0.000

< 0.016 1~14-96 340 0.018 :t 0.003

< 0.016 04-22-96 340 0.016+/-0.~ <0.<0J 1~21-96 34.l 0.0'24 :t 0.003

<0.010 04-29-96 3.37 0.017+/-0.000

< 0.015 1~28-96 34.l 0.0'26 +/- 0.003

< 0.010 05-06-96 346 0.016 +/- 0.00'2

<0.006 11-04-96 314 0.023 +/- 0.003

< 0.011 05-13-96 34.l 0.016 +/- 0.003

< 0.00'7 11-1~96 29'2 0.0'24 +/- 0.003

< 0.015 05-2~96 320 0.020 :t 0.003

<0.005 11-17-96 346 0.017 :t 0.003

< 0.016 05-28-96 399 0.014 :t 0.00'2

< 0.015 11-24-96 346 0.020 +/- 0.003

< 0.017

. 06-03-96

'172 0.019+/-0.003

< 0.020 12--01-96 348 0.0'27 +/- 0.003

<0.006 06-1~96 329 0.010 +/- 0.00'2

< 0.018 12-08-96 346 O.O'l8 +/- 0.003

< 0.014 06-17-96 311 0.017+/-0.003 < 0.011 12-16-96 399 0.0'26 +/- 0.003

<0.047 06-24-96 320 0.015+/-0.000

< 0.012 12-23-96 351 o.m1 +/-0.003

< 0.007 07--01-96 311 0.025+/-0.000

<0.COJ 12-30-96 351 0.0'26 +/- 0.003

< 0.012 2nd Quarter Meants.d. 0.011 +/- 0.004

< 0.0'20 4th Quarter Mean+/-s.d. 0.0'24 +/- O.OOoi

< 0.047 Cumulative Average:

0.022 Previous Annual Average:

0.022 1-2

fALISADES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

3HS - Covert (5 miles SE)

Units:

fD/m' Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

!mJ Gross Beta Iodine-131 Collected

!m'2 Gross Beta Iodine-131 Required I l Q il.01 ilJlZll QJll o.ozo 01--08-96 331 0.024+/-0.003

<0.CD 07--08-96 331 0.021 +/-0.003

< 0.010 01-15-96 365 0.025+/-0.003

< 0.014 07-15-96 331 0.020+/-0.003

< 0.010 01-22-96 357 0.021 +/-0.003

<0.007 07-22-96 J.l3 0.017+/-0.003

< 0.016 01-29-96 365 0.023+/-0.003

< 0.012 07-29-96 320 0.021 +/- 0.003. < 0.014 02-05-96 394 0.026 +/- 0.003

< 0.012 08-05-96 329 0.017 +/- 0.003

< 0.013 02-12-96 35' 0.025 +/- 0.003

<0.CD 08-12-96 337 0.020 +/- 0.003

< 0.015

. 02-19-96 368 0.028 +/- 0.003

< 0.013 08-19-96 337 0.029 +/- 0.003

<0.013 02-26-96 357 0.022 +/- 0.003

< 0.014 08-26-96 334 0.028 +/- 0.003

< 0.010 03--04-96 371 0.023 +/- 0.003

< 0.007 09-03-96 388 0.027 +/- 0.003

< 0.015 03-11-96 368 0.022 +/- 0.003

< 0.017 09-09-96 283 0.047 +/- 0.004

< 0.011 03-18-96 357 0.023 +/- 0.003

<0.014 09~16-96 348 0.017 +/- 0.002

< O.OO'J 03-25-96 3(i()

0.025 +/- 0.003

<0.014 09-23-96 J.l3 Q.022 +/- 0.003

<0.CD 04-01-96 368 0.020 +/- 0.003

<0.015 09-30-96 351 0.022 +/- 0.003

<0.015 1st Quarter Mean+/-s.d. 0.024 +/- 0.002

< 0.011.

3rd Quarter Mean+/-s.d. 0.024 +/- O.OOJ

< 0.016 04-08-96 35' 0.022 +/- 0.003

< 0.014 10-01-96 331 o.026 +/- o.003

< 0.013 04-15-96 365 0.020 +/- 0.003

<0.017 1~14-96 351 0.021 +/- 0.003

< 0.016 04-22-96 346 0.016 +/- 0.093

<0.CD 1~21-96 351 0.023 +/- 0.003

<0.010 04-29-96 J.l3 0.013 +/- 0.002

< 0.015 1~28-96 351 0.021 +/- 0.003

< 0.011 05-06-96 354 0.020 +/- 0.003

<0.006 11-04-96 351 0.023 +/- 0.003

<0.012 05-13-96 351 0.016 +/- 0.003

< 0.007 11-1~96 2'11 0.024 +/- 0.003

< 0.015 05-2~96 331 0.023 +/- 0.003

<.0.006 11-17-96 357 0.017 +/- 0.002

<0.016

. 05-28-96 4(8 0.016 +/- 0.002

<0.016 11-24-96 351 0.017 +/- 0.003

<0.018 06-03-96 280 0.018 +/- 0.003

< 0.021 12-01-96 3llO 0.027 +/- 0.003

<0.006 06-1~96 337 0.012+/-0.002

< 0.019 12-08-96 354 0.025 +/- 0.003

<0.015 06-17-96 329 0.019 +/- 0.003

< 0.011 12-16-96 411 0.022 +/- 0.002

< 0.048 06-24-96 331 0.014 +/- 0.003

<0.012 12-23-96

.3li0 0.000 +/- 0.003

<0.008 01-01-96 326 0.024 +/- 0.003

<0.CD 12-30-96 365 0.028 +/- 0.003

<0.012 2nd Quarter Mean+/-s.d. 0.018 +/- O.D04

< 0.021 4th Quarter Mean+/-s.d. 0.023 +/- O.O<M

< 0.048 Cumulative Average:

0.022 Previous Annual AveraS!:

0.022 1-3

fALISAC~S Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

4JS

  • Covert (3.5 miles ESE)

Units:

pO/m>

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~mj Gross Beta lodine-131 Collected (m>~

Gross Beta Iodine-131 Required I.LP OJll o.ozn

. QJll OJlZll 01-08-96 317 0.029 ~ 0.003

<0.00J 07-08-96 32(;

0.022 +/- 0.000

< 0.010 01-15-96 360 0.029 +/- 0.003

<0.014 07-15-96 320 0.018 +/- 0.003

< O.OOCJ 01-22-96 360 0.024 +/- 0.003

< 0.007 07-22-96 334 0.019 +/- 0.000

< 0.016 01-29-96 36'3 0.0'22 +/- 0.003

< 0.011 07-29-96 314 0.019 +/-0.000

< 0.014 02-05-96 371 0.0'26 +/- 0.003

<0.011 08-05-96 323 0.016 +/- 0.000

< 0.013 02-12-96 357 0.027 +/- 0.003

< O.OOJ 08-12-96 326 0.024 +/- 0.003

< 0.014. -

02-19-96 36'3 0.018 +/- 0.003

<0.013 08-19-96 323 0.024 +/- 0.000

< O.Q12 02-26-96 35' 0.018 +/- 0.003

< 0.013 08-26-96 337 0.010 +/- 0.002

< 0.010 03-04-96 36'3 0.0'22 +/- 0.003

<0.007 09-03-96 319 0.021 +/- 0.000

<0.015 03-11-96 36'3 0.021 +/- 0.003

< 0.016 09-09-96 280 0.°'5 +/- 0.004

<0.011 03-18-96 35' 0.0'25 +/- 0.003

< 0.014 09-16-96 337 0.017 +/-,0.002

< O.OOCJ*

03-25-96 35' 0.()23 +/- 0.003

<0.014 09-23-96 334 0.022 +/- 0.000

< O.OOJ 04--01-96 36'3 0.021 +/- 0.003

<0.015 09-30-96.

3.(3 0.022 +/- 0.000

<0.015 1st Quarter Mean+/-s.d. 0.()23 +/- O.OCM

<: 0.016 3rd Quarter Mean+/-s.d. O.D'22 +/- 0.008

< 0.016 04-08-96 348 0.023 +/- 0.003

<0.014 1*96

.329 0.024 +/- 0.003

< 0.013 04-15-96 351 0.019 +/- 0.003

<0.016 10-14-96 3.(3 0.019 +/-0.003 <0.016 04-22-96 348 0.017+/-0.~ <0.00J 10-21-96 3.(3 0.019 +/- 0.000

<0.010 04-29-96 337 0.016 +/- 0.003

<0.015 10-28-96 3.(3 0.024 +/- 0.000

<0.010 05-06-96 348 0.020 +/- 0.003

<0.006 11-04-96 334 0.021 +/- 0.003

<0.011 05-13-96 346 0.015 +/- 0.003

<0.oo7 11-10-96 29'Z 0.0'25 +/- 0.000

<0.015,.

05-20-96 323 0.021+/-0.om <0.006 11-17-96 351 0.015 +/- 0.002

<0.016 05-28-96 399 0.015 +/- 0.002 * <0.015 11-24-96 348 0.020 +/- 0.003

<0.017 06-03-96 272 0.018 +/- 0.003

<0.020 l2-01-96 357 0.025 +/- 0.003

<0.006 06-10-96 331 0.012 +/- 0.002

< 0.019 12-08-96 346 0.0'26 +/- 0.000

< 0.014 06-17 323 0.016 +/- 0.003

< 0.011 12-16-96 4ffi 0.021 +/- 0.000

<0.047 06-24-96 323 0.016 +/- 0:003

<0.012 12-23-96 360 0.0'29 +/- 0.000

<0.00J 07-01-96 320 0.024 +/- 0.003

<0.00J 12-30-96 360 0.024 +/- 0.003

<0.012 2nd Quarter Mean+/-s.d. 0.018 +/- 0.003

<0.020 4th Quarter Meants.d. 0.023 +/- 0.006

<0.047 Cumulative Average:

0.022 Previous Annual Average:

0.022 1-4

PALISADES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

SPR - Covert (3 miles E)

Units:

pCi/m, Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected*

!m,~

Gross Beta Iodine-131 Collected

~m,~

Gross Beta lodine-131 Reqyjm:f I LO fJJll OJlZll il.0.1

.a.JlZil 01-08-96 275 0.027 +/- O.CXM

< 0.007 07~96 286 0.019 +/- 0.003

< 0.009 01-15-96 314 0.027 +/- 0.003

< 0.012 07-15-96 283 0.019 +/- 0.003

< 0.008 01-22-96 3()IJ

. 0.025 +/- 0.003

<0.006 07-22-96 2'17 0.019 +/- 0.003

< 0.014 01-29-96 312 0.024 +/- 0.003

< 0.010 07-29-96 278 0.019 +/- 0.003

< 0.012 02-05-96 329 0.026 +/- 0.003 < 0.010 08-05-96 286 0.017 +/- 0.003

< 0.011 02-12-96 312 0.029 +/- 0.003

<0.007 08-12-96 289 0.025 +/- 0.003

< 0.012 02*19-96 314 0.018 +/- 0.003

< 0.011 08-19-96 29'2 0.025 +/- 0.003

< 0.011 02-26-96 3()IJ 0.018 +/- 0.003

< 0.012 08-26-96 289 0.027 +/- 0.003

< 0.009 03-04-96 317 0.0'23 +/- 0.003

<0.006 09~96 337 0.033 +/- 0.003 '< 0.013 03-11-96.

317 0.0'23 +/- 0.003

< 0.014 09-09-96 246 0.048 +/- 0.004

< 0.009 03-18-96 3()IJ 0.0'23 +/- 0.003

< 0.012 09-16-96 300 0.020 +/- 0.003

< 0.008 03-25-96 3()IJ 0.022 +/- 0.003

< 0.012 09-23-96 2'17 0.026 +/- 0.003

< 0.007

()4.-01-96 314 0.0'23 +/- 0.003

< 0.013 09-30-96..

300 0.022 +/- 0.003

< 0.013 1st Quarter Mean+/-s.d. 0.024 +/- 0.003

< 0.014 3rd Quarter Mean+/-s.d. 0.024 +/- 0.008

< 0.014 04-08-96 n

0.0'23 +/- 0.003

< 0.012 1~

2'17 0.026 +/- 0.003

< 0.012 04-15-96 n

0.018 +/- 0.003

<0.014 10-14-96 300 0.021 +/-0.003

< 0.014 04-22-96 300 0.017 +/- 0.000

<0.007 10-21-96 n

0.025 +/- 0.003

< 0.009 04-29-96

'1!11 0.015 +/- 0.003

<0.013 10-28-96 n

0.024 +/- 0.003

< 0.009 05-06-96 n

0.016 +/- 0.003

<0.005 11-04-96 295 0.022 +/- 0.003

< 0.010 05-13-96 300 0.017 +/- 0.003

<0.006 11-10-96 261 0.025 +/- 0.004

< 0.014 -

05-20-96 283 0.022 +/- 0.003

< 0.005 11-17-96 3()IJ 0.017 +/- 0.003

< 0.014 05-28-96 346 0.015 +/- 0.003

< 0.013 11-24-96 n

0.019 +/- 0.003

<0.015 06-03-96 244 0.015 +/- 0.003

<0.018 12-01-96 314 0.027 +/- 0.003

< 0.006 06-10-96 286 0.012+/-0.003

< 0.016 12~96 n

0.029 +/- 0.003

< 0.013 06-17-96 283.

0.018 +/- 0.003

< 0.009 12-16-96 357 0.024 '+/- 0.003

< 0.042 06-24-96 280 0.016 +/- 0.003

<0.010 12-23-96 340 0.001 +/-0.003

< 0.007 12-30-96 346 0.026 +/- 0.003 07-01-96 218 0.024 +/- 0.003

<0.007

< 0.012 2nd Quarter Mean+/-s.d. 0.018 +/- O.CXM

< 0.018 4th Quarter Mean+/-s.d. 0.024 +/- 0.004

< 0.042 Cumulative Average:

0.023 Previous Annual Avera!!:

0.022 1-5

l!ALISAI2ES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

6RB-South Haven (4.75 miles NE)

Units:

~Im' Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

!m'l Gross Beta Iodine-131 Collected

!m2 Gross Beta Iodine-131 Required. LLQ OJl1 o.oza ilJll JlJlZD 01-08-96 314 o.025+/-0.om <0.007 07-08-96 312 0.022 +/-O.om

< 0.010 01-15-96 351 0.02&+/-0.om <0.013 07-15-96

~

0.011+/-0.om

< 0.009 01-22-96 340 o.023 +/- o.om < 0.007 07-22-96 320 0.019 +/-o.om < 0.015 01-29-96 354 o.025+/-0.om < 0.011

. 07-29-96 300 0.019+/-0.om

< 0.013 02-05-96 368 o.0'27 +/- o.om

< 0.011 08--05-96

~ 0.016+/-0.om

< 0.012 02-12-96 348 o.029+/-0.om <0.WJ 08-12-96 317 0.023 +/- 0.000

< 0.014 02-19-96 357 0.016 +/- 0.002

<0.012 08-19-96 317 0.029 +/- 0.000

< 0.012 02-26-96 343 o.ot9+/-o.om <0.013 08-26-96 314 0.029 +/- 0.000

< 0.010 03-04-96 351 0.021 +/-o.om <0.007 09-03-96 365 0.029 +/- 0.000

< 0.014 03-11-96 357 0.022+/-0.om < 0.016

  • 09-09-96

'21/J 0.046 +/- 0.004

< 0~010 03-18-96 343 0.024+/-0.om < 0.014 09-16-96 326 0.020+/-0.om

<0.009 03-25-96.

346 0.021 +/-o.om <0.014 09-23-96 326 0.023 +/- 0.000

<0.WJ 04-01-96 351 o.023+/-0.om < 0.014 09-30-96..

326 0.023 +/- 0.000

< 0.014 1st Quarter Mean+/-s.d. 0.023 +/- O.O<M

<0.016 3rd Quarter Mean+/-s.d. 0.024 +/- O.WJ

< 0.015 04-08-96 3(J o.023+/-0.om <0.014 10-07-*96 320 o.025 +/- o.ooo

< 0.012 04-15-96 337 0.021 +/-o.om <0.015 10-14-96 331 0.020+/-0.om <0.015 04-22-96 337 0.015+/-0.~ <0.<0I 10-21-96 331 o.025+/-0.om

< 0.010 04-29-96 295 0.018+/-0.om <0.013 10-28-96 331 0.022+/-0.om

< 0.010 05-06-96 368 0.011 +/- 0.()()2

<0.006 11-04-96 323 0.022+/-0.om

< 0.011 05-13-96 329 0.019+/-0.om <0.007 11-10-96 280 o.023+/-0.om

< 0.015 05-20-96

~ 0.020+/-0.om <0.005 11-17-96 331 0.011+/-0.om

< 0.015 05-28-96 319 0.016 +/- 0.002

<0.015 11-24-96 334 o.ots+/-o.om <0.017

~96 2(,6 0.016+/-0.om <0.020 12-01-96 3(J

. 0.024 +/- o.om

<0.006 06-10-96 314 0.010 +/- 0.002

<0.018 12-08-96 331 o.0'27 +/- o.om

<; 0.014 06-17-96

~ 0.020+/-0.om <0.010 12-16-96 385 0.026+/-0.om <0.045 06-24-96

~

o.otS+/-o.om <0.011 12-23-96 340 0.029 +/- 0.000

<0.007 07-01-96

  • ~

0.022+/-0.om <0.WJ 12-30-96 343 0.026+/-0.om

< 0.011 2nd Quarter Mean+/-s.d. 0.018 +/- O.O<M

<0.020 4th Quarter Mean:ts.d. 0.023 +/- 0.004

< 0.045 Cumulative Average:

0.022 Previous Annual Avera~e:

0.022 1-6

PALISAQES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

750 - South Haven (7.5 miles NNE)

Units:

pCllm' Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

!m'!

Gross Beta Iodine-131 Collected (m'i Gross Beta Iodine-131 RequjrM 1.1.Q OJl1 il.OZil il.ill JlJlZO 01-08-96 320 0.028+/-0.003

<0.008 07-08-96 l34 0.023 +/-0.003

< 0.006 01-15-96 3(i()

0.028 +/- 0.003

<0.009 07-15-96 329 0.018 +/- 0.003

< 0.003 01-22-96 351 0.021 +/-0.003

< 0.010 07-22-96 343 0.020+/-0.003

< 0.006 01-29-96 351 0.024+/-0.003

<0.004 07-29-96 323 0.020 +/- 0.003

<0.009 02-0S-96 371 0.026 +/- 0.003

<0.006 OS-OS-96 329 0.015 +/- 0.003

< 0.011 02,.12-96 346 0.028+/-0.003

<0.006 08-12"'.96

'337 0.023 +/-0.003

< 0.008 02-19-96 354 0.019+/-0.003

< 0.008 08-19-96 340 0.026 +/- 0.003

< 0.014 02-26-96 348 0.019+/-0.003

<0.003 08-26-96

'337 0.029 +/- 0.003

<0.006 03-04-96 361 0.021 +/-0.003

<0.008 09-03-96 388.

0.029 +/- 0.003

< 0.005 03-11-96 365 0.023 +/- 0.003

<0.006 09-09-96 286 0.043 +/- 0.004

< 0.011 03-18-96 354 o.023 +/- o.003

< 0.009 09-16-96 348 0.020 +/- 0.003

< 0.010 03-25-96 351 0.024. +/-. 0.003

< 0.007 09-23-96 346 0.027+/-0.003 < 0.008 04-01-96 354 0.022 +/- 0.003

<0.009 09-30-96 346 0.021 +/- 0.003

< 0.012 1st Quarter Mean+/-s.d. 0.023 +/- 0.003

< 0.010 3rd Quarter Mean:ts.d. 0.024 +/- 0.007. < 0.014

~96 346 0.023 +/- 0.003

<0.008 l<MJ?-96

'337 0.027 +/- 0.003

< 0.008 04-15-96 348 0.019 +/- 0.003

<0.009 1()-14-96 354 0.020 +/- 0.003 ' < 0.00'7 04-22-96 346 0.018+/-0.()(B

< 0.010 1()-21-96 351 0.024 +/- 0.003. < 0.010.

.04-29-96 343 0.017 +/- 0.003

<0.008 1()-28-96 351 0.023 +/- 0.003

< 0.008 05-06-96 357 0.016 +/- 0.002

<0.006 11-04-96 354 0.024 +/- 0.003

< 0.011 05-13-96 348 0.016 +/- 0.003. < 0~004 11-1()-96 2'P 0.022 +/- 0.003

< 0.009 05-2()-96 329 0.021 +/- 0.003

<0.005 11-17-96 354 0.016 +/- 0.002

< 0.009 05-28-96 399 0.017 +/- 0.002

< 0.004 11-24-96 354 0.021 +/- 0.003

< 0.010 06-03-96 286 0.017 +/- 0.003

< 0.011 12-01-96 3(i()

0.027 +/- 0.003

<0.006 06-1()-96 334 0.010 +/- 0.002

<0.009 12-()8..96 351 0.028 +/- 0.003

<0.006 06-17-96

'331 0.019 +/- 0.003

< 0.008 12-16-96 411 0.024 +/- 0.003

< 0.0'28 06-24-96

'331 0.014 +/- 0.003

<0.004 12-23-96 3(i()

0.003 +/- 0.003

< 0.010.

07-01-96 329 0.021 +/-0.003

<0.006 12-30-96 365 0.025 +/- 0.003

< 0.011 2nd Quarter Mean+/-s.d. 0.018 +/-. 0.003

< 0.011

  • 4th Quarter Mean:t:s.d. 0.024 +/- 0.004

< O.o28 Cumulative Average:

0.022 Previous Annual Average:

0.023 1-7

fALISACES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

8SP - State Park (1 mile N)

Units:

pCJ/m, Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

{mJ Gross Beta Iodine-131 Collected

~m,~

Gross Beta lodine-131 Required LLP OJl1 OJlZQ il.ill JlJlZO 01-08-96 3()1) 0.027 +/- 0.003 * < O.<nJ 07-08-96 320 0.025 +/- 0.003

< 0.006 01-15-96 351 0.029 +/- 0.003

< O.<nJ 07-15-96 314 0.018 +/- 0.003

< 0.003 01-22-96 340 0.021 +/- 0.003

<0.009 07-22-96 323 0.018 +/- 0.003

< 0~006 01-29-96 351 0.024 +/- 0.003

< 0.004 07-29-96 3m 0.020 +/- 0.003

< 0.009 02-05-96 365 0.027 +/- 0.003

<0.006 08-05-96 317 0.016 +/- 0.003

<*0.011 02-12-96 346 0.026 +/- 0.003

< 0.006 08-12-96 320 0.022 +/- 0.003

< 0.007 02-19-96 354

. 0.019 +/-0.003

< 0.(Q 08-19-96 323 0.026 +/- 0.003

< 0.013 02-26-96

. 346 0.017 +/- 0.003

< 0.003 08-26-96 320 0.028 +/- 0.003

< 0.006 03-04-96 354 0.024. +/- 0.003

< 0.(Q 09-03-96 368 o.mo+/-o.003 < 0.005 03-11-96 351 0.024 +/- 0.003

< 0.006 09-09-96 275 0.043 +/- 0.004

< 0.011 03-18-96

.346 0.029 +/- 0.003

< O.OOIJ 09-16-96 331 0.018 +/- 0.003

< 0.009 03-25-96 346 0.027 +/- 0.003

< 0.007 09-23-96 329 0.025 +/- 0.003

< O.<nJ 04--01-96 351 0.022 +/- 0.003

<0.009 09-30-96 331 0.020 +/- 0.003

<0.012 1st Quarter Mean+/-s.d. 0.024 +/- 0.004

< 0.009 3rd Quarter Mean+/-s.d. 0.024 +/- 0.007 < 0.013 04-08-96 340 0.021 +/- 0.003

<0.<D 1~ 331 0.025 +/- 0.003

<0.<81 04-15-96 348 0.020 +/- 0.003

< 0.009 10-14-96 334 0.019 +/- 0.003

< 0.007 04-22-96 331 0.016 +/- O.()(p

<0.009 10-21-96 334 0.023 +/- 0.003

< 0.009 04-29-96 331 0.017 ~ 0.003

<0.<D 10-28-96 337 0.0'20 +/- 0.003

< 0.007.

05--06-96 329 0.014 +/- 0.002

<0.005 11496 320 0.023 +/- 0.003

< 0.010 05-13-96 33f 0.016 +/- 0.003

<0.<XM 11-10-96 286 0.0'21 +/- 0.003

<0.009

. 05-20-96 312 0.022 +/- 0.003

<0.005 11-17-96 340 0.018 +/- 0.003

< 0.009 05-28-96 385 0.017 +/- 0.002

<0.<XM 11-24-96.

334 0.019 +/- 0.003

< 0.010 06-03-96 2JIJ 0.018 +/- 0.003

< 0.010 12-01-96 340 0.025 +/- 0.003

<0.006 06-10-96 320 0.010 +/- 0.002

<0.(Q 12-08-96

. 334 0.027 +/- 0.003

<0.006 06-17-96 314 0.019 +/- 0.003

<0.<D 12-16-96 388 0.0'24 +/- 0.003

< 0.026 06-24-96 314 0.016 +/- 0.003

<0.<XM 12-23-96 346 0.029 +/- 0.003

< 0.010 07-01-96 312 0.0'20 +/- 0.003

<0.005 12-30-96 348 0.0'26 +/- 0.003

< 0.010 2nd Quarter Meants.d. 0.017 +/- 0.003

<0.010 4th Quarter Mean+/-s.d. 0.023 +/- 0.003

< 0.026.

Cumulative Average:

0.022 Previous Annual Avera~e:

0.022 1-8

£ALISADf:S Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

9TP - Covert Township Park (1.5 miles S)

Units:

p::J/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~ml~

Gross Beta Iodine-131 Collected (ml)

Gross Beta lodine-131 Required LLD ilJll OJl'Z1l o.m.

il.OZil 01-08-96 323 0.027 +/- 0.003

<0.~

07-08-96 323 0.023 +/-0.003

<0.006 01-15-96 363 0.0'26 +/- 0.003

< O.OO'J 07-15-96 326 0.018 +/-0.003

< 0.003 01-22-96 354 0.019 +/-0.003

< 0.010 07-22-96 340 0.020+/-0.003

< 0.006 01-29-96 365 0.024 +/- 0.003

< 0.004 07-29-96 320 0.017 +/-0.003

< 0.009 02-05-96 379 0.026 +/- 0.003

<0.006 08-05-96 326 0.014 +/-0.003

< 0.011 02-12-96 3(,()

0.028 +/- 0.003

<0.007 08-12-96 334 0.021 +/-0.003

<0.~

02-19-96 368 0.018 +/- 0.003

<0.~

08-19-96 337 0.024 +/-0.003

< 0.014 02-26-96 354 0.017 +/- 0.003

<0.003 08-26-96 334 0.029 +/-0.003

< 0.006 03-04-96 365 0.023 +/- 0.003

<0.~

09-03-96 3&5 0.027+/-0.003 < 0.005 03-11-96 363 0.023 +/- 0.003

<0.006 09-09-96 286 0.047 +/- 0.004. < 0.011 03-18-96 354 0.023 +/- 0.003

<0.009 09-16-96 340 0.019 +/-0.003

<0.009 03-25-96 351

. 0.022 +/- 0.003

<0.007 09-23-96 34.1 0.022 +/-0.003

<0.~

04-01-96 365 0.020 +/- 0.003

<0.010 09-30-96 34.1 0.022+/-0.003 < 0.012' 1st Quarter Mean+/-s.d. 0.023 +/- 0.004

< 0.010 3rd Quarter Mean+/-s.d. 0.023 +/- 0.008

< 0.014 04-08-96 348 0.022 +/- 0.003

<0.006 1()-0;1;96 331 0.028+/-0.003

<0.~

04-15-96 363 0.019 +/- 0.003

< O.OO'J 10-14-96 346 0.019+/-0.003

< 0.007 04-22-96 340 0.018 +/- 0.003

<0.010 10-21-96.

34.1 0.024+/-0.003 < 0.010 04-29-96 329 0.019 +/-0.003

<0.~

10-28-96 34.1 0.024 +/-0.003

<0.007 05-06-96 334 0.017 +/- 0.003 ' < 0.005' 11-04-96 331 0.020+/-0.003

< 0.010 05-13-96 334 0.017 +/- 0.003

<0.004 11-10-96 292 0.024+/-0.003 < O.OO'J.

05-20-96 314 0.023 +/- 0.003

<0.005 11-17-96 340 0.018+/-0.003 <0.009 05-28-96 39' 0.014 +/- 0.002

<0.004 11-24-96 346 0.019+/-0.003 < 0.010 06-03-96 263 0.020 +/- 0.003

<0.010*

12-01-96 348 0.027+/-0.003 <0.006 06-10-96 317 0.011 +/- 0.002

<0.~

12-08-96 348 0.029 +/-0.003

<0.006 06-17-96 320 0.018 +/- 0.003

<0.~

12-16-96 4(12 0.024 +/- 0.003

< 0.027

  • 06-24-96 317 0.016 +/- 0.003

<0.004 12-23-96 3(,()

0.000 +/- 0.003

< 0.010 07-01-96 312 0.021 +/- 0.003

<0.005 12-30-96 363 0.023 +/- 0.003

< 0.010 2nd Quaz:ter Mean+/-s.d. 0.018 +/- 0.003

<0.010 4th Quarter Mean+/-s.d. 0.024 +/- 0.004

< 0.027 Cumulative Average:

0.022 Previous Annual Average:

0.021 1-9

fALISAI2ES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

lOGR -Grand Rapids (55 mi NNE)

Units:

pO/m, Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~m,}*

Gross Beta Iodine-131 Collected

~m,}

Gross Beta Iodine-131 Required I.LP.

OJll QJlZil ilJll OJlZil 01-04-96 368 0.002 +/- 0.003

<0.009.

07-11-96 368 0.020 +/- 0.000

< 0.006 01-11-96 3(,()

0.030 +/- 0.003

< 0.011 07-18-96 312 0.024 +/- 0.000

<0.008 01-18-96 348 0.001 +/- 0.003

<0.013 07-25-96 331 0.016 +/- 0.000

< 0.011 01-25-96 357 0.023 +/- 0.003

<0.006 08-01-96 337 0.019 +/- ().000

<0.014 02-01-96 357 0.020 +/- o.003

< 0.0'20 08-08-96 317 0.023 +/- 0.000

<0.009 02-08-96 3(,()

0.029 +/- 0.003

<0.009 08-15-96 317 0.020 +/- 0.000

< 0.019 02-15-96 36'3 0.017 +/- 0.003

< 0.010 08-22-96 334 0.023 +/- 0.000

<0.009 02-22-96 354 0.0'20 +/- 0.003

<0.00&

08-29-96 320 0.025 +/- 0.000

<0.009 02-29-96 348 0.015 +/- 0.002

<0.013 09-05-96 314 0.007 +/- 0.004

<0.013 03-07-96 3(,()

0.025 +/- 0.003

<0.010 09-12-96 320 0.035 +/- 0.000

< 0.013 00-14-96 346 0.026 +/- 0.003

<0;012 09-19-96 331

. 0.013 +/- 0.002 < 0.013 00-21-96

. 348 0.018 +/- 0.003

< 0.010 09-25-96 326 0.024 +/- 0.000

<0.017 00-28-96 346 0.023 +/- 0.003

< 0.013 10-oo-96 331 0.021 +/- 0.000

<0.015 1st Quarter Mean+/-s.d. 0.0'24 +/- 0.005

<0.020 3rd Quarter Mean+/-s.d. 0.023 +/- 0.007

< 0.019 04-04-96 340 0.022 +/- 0.003

<0.011 10-1ci.96 33~

0.019 +/- 0.000

<0.019 04-11-96 348 0.0'20 +/- 0.003

< 0.012 10-17-96 329 0.0'28 +/- 0.000

< 0.021 04-18-96 340 0.018+/-0.~ < 0.012 10-24-96 334 0.013 +/- 0.002

<0.012 04-25-96 334 0.017 +/- 0.003

<0.011 10-31-96 337 0.025 +/- 0.000

< 0.016 05-02-96 337 0.016 +/- 0.002

<0.007 11-07-96 337 0.000 +/- 0.000

<0.009 05-09-96 331 0.018 +/- 0;003

<0.006 11-14-96 337 0.014 +/- 0.002

<0.011 05-16-96 334 0.018 +/- 0.003

<0.006 11-21-96 351 0.019 +/- 0.000

<0.016 05-23-96 306 0.021 +/- 0.003

<0.lDI 11-27-96 295 0.020 +/- 0.000

<0.010 05-~96 343 0.017 +/- 0.003

<0.011

  • 12-04-96 346 0.004 +/- 0.000

< 0.008 06-06-96 326 0.015 +/- 0.003

<0.011 12-11-96

. 343 0.027 +/- 0.000

< 0.001 06-13-96 3()IJ 0.012 +/- 0.003

< 0.011 12-19-96 346 0.023 +/- 0.000

<0.014 06-20-96 317 0.022 +/- 0.003

<0.005 12-26-96 319 0.025 +/- 0.000

<0.022 06-27-96 326 0.013 +/- 0.003. < 0.00'1 01-02-97 343 0.000 +/- 0.000

< 0.018 07-00-96 212 0.027 +/- 0.003

<0.010 4th Quarter Mean+/-s.d. 0.024 +/- 0.007

< 0.022 2nd Quarter Mean+/-s.d. 0.018+/- 0.00&. < 0.012 Cumulative Average:

0.0'22 Previous Annual Avera.s=

0.0'21 1-10

PALISADES Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

1 lKZ

  • KaJamaz.oo (35 miles E)

Units:

pO/m' Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~m,l Gross Beta lodine-131 Collected

~m'l Gross Beta lodine-131 Required LI.Q il.il1 ilJlZil ilJll ilJlZil 01--04-96

~ 0.023 +/- 0.002

< 0.019 07-05-96 379 0.023 +/- 0.003

< 0.014 01*11*96 368 0.027 +/- 0.003

<0.012 07*11*96 289 0.022 +/- 0.003

< 0.005 01*18-96 351 0.002 +/- 0.003

< 0.013 07-18-96 3.31 0.025 +/- 0.003

< 0.009 01-25-96 365 0.021 +/- 0.003

< 0.006 07*25-96 3.34 0.018 +/- 0.003

< 0.011 02-01*96 224 0.006 +/- 0.005

<0.013 08-01-96 3.34 0.017 +/- 0.003

< 0.015 02-08-96 374 0.003 +/- 0.003

< 0.009 08-08-96 3.34 0.022 +/- 0.003

< 0.009 02*15-96 363 0.021 +/- 0.003

<0.010 08-15-96 329 0.023 +/- 0.003

< 0.020 02*22*96 351 0.018 +/- 0.003

<0.005 08-22*96 320 O.OZJ +/- 0.003

< 0.009 02-29-96

. 38) 0.017 +/- 0.003

< 0.013 08-29-96 3.34 0.027 +/- 0.003

< 0.009 00-07-96 351 0.027 +/- 0.003

<0.010 09-06-96 329 0.041 +/- 0.004

< 0.012 03-14-96 365 0.024 +/-0.003 <0.013 09-13-96 371 0.001 +/- 0.003

< 0.011 03-21-96

38) 0.022 +/- 0.003

<0.010 09-19-96 306 0.014 +/- 0.003

< 0.012 03-28-96 351 0.020 +/- 0.003 <0.013 09-25-96 323 0.028 +/- 0.003

< 0.017.

1st Quarter Mean+/-s.d. 0.025 +/- 0.006 < 0.019 10-03-96 280 0.026 +/- 0.003

< 0.013 3rd~

Mean+/-s.d. 0.024 +/- 0.007 <0.020 04-04-96 354 0.021 +/-0.003 <0.012 04-11-96 363 0.018 +/- 0.002 < 0.013 10-10-96*

238 0.022 +/- 0.004

< 0.013 04-18-96 351 0.019+/-0.Gm <0.013 10-17*96 w

0.004 +/- 0.004

< 0.017 04-25-96 343 0.019+/-0.om < 0.011 10-24-96 3m 0.019 +/-0.000

< 0.011 05-02-96 351 0.014 +/- 0.002 < 0.00'7 10-31*96 312 0.028 +/- 0.000

< 0.015 05-09-96 348 0.019 +/- o.om. < o.006 11-07*96 30')

0.020 +/- 0.004

< 0.011 05-16-96 351 0.017 +/- 0.002

<0.006 11-14-96 3.31 0.018 +/- 0.003

< 0.011 05-23-96 3.31 0.022+/-0.om <0.009 11-21*96 306 0.022 +/- 0.003

< 0.014 05->>96 354 0.019+/-0.om <0.011 11-27-96

'J:JP:

0.00'7 +/- 0.002

< 0.010 06-06-96 3.37 0.013 +/- 0.000

<0.011 12-04-96 368 0.002 +/- 0.003

< 0.007 06-13-96 329 0.012 +/- 0.002 < 0.012 12-11*96 312 0.004 +/- 0.003

<0.046 06-20-96 329 0.026 +/- 0.003 <0.006 12*19-96 314 0.025 +/- 0.003

< 0.015 06-26-96 329 0.015 +/- 0.003

<0.00'7 12*26-96 292 0.033 +/- 0.003

< 0.017 2nd Quarter Mean+/-s.d. 0.018 +/- 0.00&

< 0.013 01-02-97 306 0.033 +/- 9,004

< 0.016

- 4th Quarter Mean+/-s.d. 0.025 +/- 0.008

< 0.046-Cumulative Average:

0.023 Previous Annual Avera~

0.022

  • Filter light.

1*11

~ALISACE5 Table 1.

Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location:

12DG - Dowagiac (30 miles $E)

Units:

pG/mJ Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

~mJ~

Gross Beta Iodine-131 Collected (mJ)

Gross Beta Iodine-131 Required LLD OJll OJlZil ilJll QJlZil 01-03-96 2.29 0.032 +/- 0.004

<0.016 07-10-96 30'J 0.020 +/- 0.003

< 0.005 01-10-96 340 0.030 +/- 0.003

< 0.013 07-17-96 292 0.027 +/- 0.003

<0.00J 01-17-96 340 0.031 +/- 0.003

< 0.014 07-24-96 30'J 0.018 +/- 0.003

< 0.013 01-24-96 320 0.025 +/- 0.003

<0.007 07-31-96 306 0.017 +/- 0.003

< 0.016 01-31-96 340 0.022 +/- 0.003

< 0.009 08-07-96 292 0.024 +/- 0.003

< 0.012 02-07-96 354 0.032 +/- 0.003

< o.()()lj 08-14-96 306 0.023 +/- 0.003

< 0.019 0.017 +/- 0.003

< 0.013 02-14-96 320 08-21-96 331 0.024 +/- 0.003

< O.OOJ 02-21-96 329 0.018 +/- 0.003

< 0.005 08-27-96 261 0.025 +/- 0.003

<0.006 02-28-96 329 0.019 +/- 0.003

<0.012 09-04-96 346 0.035 +/- 0.003

<0.013 03-06-96 323 0.027 +/- 0.003

<0.009 09-11-96 w

0.036 +/- 0.004

< 0.015 03-13-96

'331 0.023 +/- 0.003

<0.014 09-18-96 295 0.016 +/- 0.003

< 0.013 03-20-96 317 0.023 +/- 0.003

<0.012 09-26-96 30'J 0.023 +/- 0.003

<0.019 03-27-96 326 0.021 +/- 0.003

<0.015 10-02-96 30!1 0.025 :i: 0.003

< 0.012 04-03-96 320 0.022 +/- 0.003

<0.013 3rd Quarter Mean+/-s.d. 0.024 +/- 0.006

< 0.019

. 1st Quarter Mean+/-s.d. 0.024 +/- 0.005

<0.016 10-09-96 30!1 0.019 +/-0.003

< 0.011 04-10-96 314 0.020 +/- 0.003

< 0.015 10-16-96 30'J 0.026 +/- 0.003 '< 0.015 04-17-%

212 0.022 +/- 0.004

<0.022 i0-23-96 306 0.020 +/- 0.003

<0.012 04-24-96 331 0.016 +/- 0.003

< 0.012 10-30-96 30!1 0.026 +/- 0.003

< 0.016 05-01-96 329 0.015 +/- 0.00'2

<0.(Q U.-06-96 317 0.016 +/- 0.003

< 0.011 05-08-96 320 O.Q21 +/- 0.003

<0.007 11-13-96 184.

0.018 +/- 0.004

<0.022 05-15-96 326 0.017 +/- 0.003

<0.007 11-20-96 3(B 0.025 +/- 0.003

< 0.015 05-22-96 314 0.0'21 +/- 0.003

<0.(Q 11-27-96 391 0.010 +/- 0.00'2

< 0.014 05-29-96 314 0.020 +/- 0.003

<0.013 12-04-96 365 0.028 +/- 0.003

<0.CD 06-06-96 "la 0.015 +/- 0.003

< 0.012 12-11-96 365 0.028 +/- 0.003

<0.001 06-12-96 280 0.012 +/- 0.003

<0.013 12-19-96 326 0.028 +/- 0.003

< 0.015 06-19-96 30'J 0.025 +/- 0.003

<0.006 12-24-96 326 0.026 +/- 0.003

< 0.011 06-26-96 30!1 0.017 +/- 0.003

<0.CD 01-02-97 199 0.064 +/- 0.006

<0.026 07-03-96 300 0.023 +/- 0.003

<0.CD 4th Quarter Mean+/-s.d. 0.026 +/- 0.013

< 0.026 2nd Quarter Mean+/-s.d. 0.019 +/- 0.004

< 0.022 CumuJative Average:

0.023 Previous Annual AveraS!:

0.0'23

  • Low volume due ID pump found not running.

1-12

PALISADES Table 2.

Gamma Radiation, as measured by TI.Os, monthly exposure.

Units: mR/30 days 1

lanuai:y Date Placed U/31/95 Date Removed 2/4/96 lntransit (mR) 3.S +/- 0.2 ST-01 3.3+/- 0.2 ST-o2 4.7+/- 0.2 ST-03 3.9+/- 0.2 ST-04 4.0+/- 0.2

ST-07A 3.9+/- 0.2 ST-08 3.6+/- 0.2 ST-09 3.8+/- 0.2 ST-10 4.0+/- 0.2 ST-11 4.0+/- 0.2 ST-12 3.8+/- 0.2 ST-13 3.5+/- 0.2 ST-14 3.5+/- 0.2 ST-15 3.5+/- 0.2 ST-16.

3.9+/- 0.2 St-17 3.3+/- 0.2 ST-t8 3.6+/- 0.2 ST-19 3.9+/- 0.2 ST~20 3.5+/- 0.2.

ST-21 3.8+/- 0.2 ST-22 2.2+/- 0.2 ST-23 4.4+/- 0.2 ST-24 3.4+/- 0.2 ST-33 3.4+/- 0.2 ST-34 3.6+/- 0.2 ST-35 4.4+/-0.2 51-36 3.2+/- 0.2 ST-37 3.3+/- 0.2 ST-38 3.1+/- 0.2 Mean+/-s.d.

3.7+/- o.s Control I 1.9+/- 0.2 Control2 1.9+/- 0.2

  • Intransit exposure has been subtracted.

b ND = No data; TLD lost in the field.

februacy 2/4/96 3/3/96 4.7 +/- 0.2 3.5+/- 0.2 4.4+/- 0.2 3.4+/- 0~2 4.3+/- 0.2 3.9+/- ().2 3.1+/- 0.2 3.6+/- 0.2 3.7+/- 0.2 3.5+/- 0.2 3.2+/- 0.2 4.6+/- 0.2 4.0+/- 0.2.

3.3+/- 0.2 3.4+/- 0.2 2.9+/- 0.2 2.8+/- 0.2 3.2+/- 0.2 3.4+/- 0.2 3.5+/- 0.2 3.4+/- 0.2 3.3+/- 0.2 1.8+/- 0.2 3.5+/- 0.2 3.2+/- 0.2 3.1+/- 0.2 3.4+/- 0.2 4.2+/- 0.2 3.6+/- 0.2 3.5+/- 0.2 3.5+/- 0.2 3.5 +/- o.s 1.5+/- 0.2 1.5+/- 0.2 2-1 March 3/3/96 3/31/96 4.1+/-0.2 3.8+/- 0.2 5.2+/- 0.2 4.1+/-0.2 4.3+/- 0.2 4.4+/- 0.2 3.9+/- 0.2 4.4+/- 0.2 3.8+/- 0.3 3.9+/- 0.2 3.8+/- 0.3 4.3+/- 0.2 3.9+/- 0.2 3.6+/- 0.2 3.7+/- 0.2 3.8+/- 0.2 4.1+/-0.2 3.8+/- 0.3 3.9+/- 0.2 4.0+/- 0.2 3.8+/- 0.3 4.1+/-0.2 2.0+/- 0.2 4.7+/-0.2 3.4+/- 0.3 3.7+/- 0.2 3.8+/- 0.2 4.8+/- 0.2 3.4+/- 0.2 3.7+/- 0.2.

3.0+/- 0.2 3.9 +/- 0.6 1.7+/- 0.2 1.7+/- 0.2

PALISAQES

. Table 2:

Gamma Radiation, as measured by 11.Ds, monthly exposure.

Units: mR/30 days 1

Al2Iil Date Placed 3/31/96 Date Removed 4/'19/96 Intransit (mR) 3.3 +/-0.2 ST-01 3.5+/- 0.2 ST-02 4.4+/- 0.2 ST-03 3.6+/- 0.2 ST-04 4.2+/- 0.2 ST-05 3.9+/- 0.3 ST-06 3.1+/- 0.2 ST-07A.

3.5+/- 0.2 ST-08 3.8+/- 0.2 ST-09 3.8+/- 0.2 ST-10 3.3+/- 0.2 ST-11 4.3+/- 0.2 ST-12 3.9+/- 0.3 ST-13 3.1+/- 0.2 ST-14 3.2+/- 0.2 ST-15 3.1+/- 0.2 ST-16 3.1+/- 0.2 St-17 3.1+/- 0.2 ST-18 3.3+/- 0.2 ST-19 3.5+/- 0.3 ST-20 3.7+/- 0.3 ST-21

. 3.5+/- 0.3 ST-22 1.6+/- 0.2 ST-23 3.5+/- 0.2 ST-24 3.1+/- 0.2 ST-33 2.8+/- 0.2 ST-34 3.1+/- 0.2.

ST-35 3.9+/- 0.2 ST-36 3.1+/- 0.2 ST-37 3.2+/- 0.3 ST-38 3.1+/- 0.2 Mean+/-s.d.

3.4 +/- 0.5 Control 1 1.S+/-*0.2 Control2 1.6+/- 0.2 1 lntransit exposure has been subtracted.

b ND= No data; TLD lost.in the field.

~

4/29/96 6/2./96 3.6+/-0.2 3.6+/- 0.2 4.8+/- 0.2 3.9+/- 0.2 4.1+/- 0.2 4.1+/- 0.2 3.6+/- 0.2 3.7+/- 0.2 3.7+/- 0.2 3.4+/- 0.2 3.3+/- 0.2 NDb 3.8+/- 0.2 3.3+/- 0.2 3.2+/- 0.2 3.4+/- 0.2 3.3+/- 0.2 3.3+/- 0.2 3.7+/- 0.2 3.6+/- 0.2 3.4+/- 0.2 3.5+/- 0.2 1.9+/- 0.2 4.2+/- 0.2 3.3+/- 0.2 3.0+/- 0.2 3.3+/- 0.2 4.0+/- 0.2 2.9+/- 0.2 3.0+/- 0.2 3.0+/- 0.2 3.5 +/- 0.5 1.8+/- 0.2 1.8+/- 0.2 2-2 m

6/2/96 7/1/96 3.4 +/-0.2 3.6+/- 0.2 4.8+/- 0.2 3.6+/- 0.2 4.4+/- 0.2 4.0+/- 0.2 3.4+/- 0.3 3.6+/- 0.2 3.8+/- 0.2 3.6+/- 0.2 3.3+/- 0.2 5.2+/- 0.2 3.9+/- 0.2 3.2+/- 0.3 3.1+/- 0.2 3.3+/- 0.2 2.9+/- 0.3 3.2+/- 0.2 3.5+/- 0.2 3.6+/- 0.2 3.3+/- 0.2 3.2+/- 0.2 2.0+/- 0.2

. 3.6+/- 0.2 3.2+/- 0.2 2.9+/- 0.2 3.1+/- 0.2 3.9+/- 0.2 3.3+/- 0.2 3.2+/- 0.2 3.2+/- 0.2 3.5 +/- 0.6 1.7+/- 0.2 1.7+/- 0.2

PALISADES Table 2.

Gamma Radiation, as measured by TI.Os, monthly exposure.

Units: mR/30 days*

~

Date Placed 7/1/96 Date Removed 8/4/96 Intransit (mR) 3.3 +/-0.2 ST-01 3.5+/- 0.2 ST-02 5.3+/- 0.2 ST-03 3.9+/- 0.2 ST-04 4.4+/- 0.2 ST-05 4.3+/- 0.2 ST-06 3.8+/- 0.2 ST-07A 4.0+/-02 ST-08 3.9+/-0.2 ST-09 3.5+/- 0.2 ST-10 3.2+/- 0.2 ST-11 5.0+/- 0.2 ST-12 3.9+/- 0.2 ST-13 3.2+/- 0.2 ST-14 3.1+/- 0.2 ST-15 3.5+/- 0.2 ST-16 3.3+/- 0.2 St-17 3.4+/- 0.2 ST-18 3.8+/- 0.2 ST-19 3.9+/- 0.2 ST-20 3.8+/- 0.2 ST-21 3.9+/- 0.2 ST-22 2.0+/- 0.2 ST-23 4.4+/- 0.2.

ST-24 3.8+/- 0.3 ST-33 3.2+/- 0.2 ST-34 3.5+/- 0.2 ST-35 4.2+/- 0.2 ST-36 3.1+/- 0.2 ST-37 3.3+/- 0.2 ST-38 3.2+/- 0.2 Mean+/-s.d.

3.7 +/- 0.6 Controll 1.8+/- 0.2 Control2 1.8+/- 0.2

  • Intransit exposure has been subtracted.

b ND = No data; TLD lost in the field.

August 8/4/96 9/1/96 4.7 +/-0.2 3.9+/- 0.2 5.6+/- 0.2 4.2+/- 0.2 4.7+/- 0.2 4.8+/- 0.2 4.1 +/- 0.2 4.3+/- 0.2 4.3+/- 0.2 4.3+/- 0.2 3.9+/- 0.2 5.6+/- 0.2 4.4+/- 0.2 3.8+/- 0.2 3.9+/- 0.2 3.8+/- 0.2 3.5+/- 0.2 3.6+/- 0.2 4.0+/- 0.2 4.2+/- Q.2 4.2+/- 0.2 3.9+/- 0.2 2.1+/-0.2 4.3+/- o.z 3.9+/- 0.2 3.3+/- 0.2 3.6+/- 0.2 4.3+/- 0.2 3.8+/- 0.2 3.9+/- 0.2 3.9+/- 0.2 4.1+/-0.6 1.6+/- 0.2 2.0+/- 0.2 2-3 S1:12temb£i:

9/1/96 9/'29/96 4.7 +/-0.2 3.7+/- 0.2 5.9+/- 0.3 4.8+/- 0.3 5.0+/- 0.3 4.5+/- 0.3 4.0+/- 0.2 4.2+/- 0.2 4.3+/- 0.2 3.8+/- 0.2 3.6+/- 0.2 5.4+/- 0.2.

4.1+/-0.2 3.6+/- 0.2 3.3+/- 0.2 3.9+/- 0.2 4.1+/-0.2 4.0+/- 0.2 4.5+/- 0.2 4.3+/- 0.2 4.0+/- 0.2 4.5+/- 0.2 2.0+/- 0.2 4.9+/- 0.2 4.1+/-0.2 3.7+/- 0.2 4.1+/- 0.2 4.8+/- 0.2 3.6+/- 0.2 3.7+/- 0.2 3.7+/- 0.2 4.1 +/-0.7 1.9+/- 0.2 1.9+/- 0.2

PALISADES Table 2.

Gamma Radia.tion, as measured by TI.Os, monthly exposure.

Units:. mR/30 days*

Q;tpber Date Placed 9/'19196 Date Removed 11/3/96 Intransit (mR) 3.S +/-0.2 ST-01 3.7+/- 0.2 ST-02 5.5+/- 0.2 ST-03.

4.0+/- 0.2 ST-04 4.7+/- 0.2 ST-05 4.9+/- 0.2 ST-06 3.1+/- 0.2 ST-07A 4.2+/- 0.2 ST-08 4.2+/- 0.2 ST-09 3.1+/- 0.2 ST-10 3.7+/- 0.2 ST-11 4.7+/- 0.2 ST-12 4.S+/- 0.2 ST-13 3.4+/-0.2 ST-14 3.3+/- 0.2 ST-15 3.S+/- 0.2 ST-16 3.0+/- 0.2 St-17.

3.4+/-0.2 ST-18 3.7+/-0.2 ST-19 4.0+/- 0.2 ST.;.20 3.8+/- 0.2 ST-21 3.7*+/- 0.2 ST-22 1.9+/- 0.2

ST-37 3.1+/- 0.2.

ST-38 3.4+/- 0.2 Mean+/-s.d.

3.8+/- 0.7 Control 1 1.7+/- 0.2 Control2 1.7+/- 0.2

  • Intransit exposure has been subtracted.

b ND= No data; TLD lost in the field.

Noyember 11/3/96 12/1/96 5.1 +/-0.2 3.6+/- 0.3 5.7+/- 0.2 4.4+/- 0.2 4.8+/- 0.2 5.3+/- 0.2 4.3+/- 0.2 4.3+/- 0.2 4.3+/- 0.2 3.6+/- 0.2 3.6+/- 0.3 4.8+/- 0.2 4.0+/- 0.2 3.3+/- 0.2 3.4+/- 0.2 3.8+/- 0.2 3:1+/- 0.2 3.4:1: 0.2 3.9+/- 0.3 3.9+/- 0.2 3.4+/- 0.2 3.7+/- 0.2 2.0+/- 0.2 4.5+/- 0.2 3.4+/- 0.2 3.4+/- 0.3 3.5+/-0.2 4.7+/- 0.2 3.0+/- 0.2 3.0+/- 0.2 2.9+/- 0.2 3.9 +/- 0.8 1.8+/- 0.2 1.8+/- 0.2 2-4

~mher 12/1/96 1/2/'ll 4.2 +/-0.2 3.5+/- 0.2 5.1+/-0.2 4.5+/- 0.2 5.1+/-0.2 4.7+/- 0.2 3.8+/- 0.2 4.4+/- 0.2 4.6+/- 0.2 4.1+/-0.2 3.8+/- 0.2 4.9+/- 0.2 4.5+/- 0.2 3.7+/- 0.2 3.7+/- 0.2 4.2+/- 0.2 3.S+/- 0.2 3.7+/- 0.2 4.1+/- 0.2 4.1+/- 0.2 4.1+/-0.2 4.1+/-0.2 1.8+/- 0.2 4.1+/- 0.2 4.2+/-0.2 3.4+/- 0.2 3.8+/- 0.2 5.1+/- 0.2 4.1+/- 0.2 4.2+/- 0.2 3.8+/- 0.2 4.1+/-0.6 1.8+/- 0.2 1.8+/- 0.2

PALISAQES Table 3.

Gamma Radiation. as measured by TI.Os, quarterly exposure.

Units: mR/91 days na-Date Placed Date Removed Intransit (mR)

ST-01 ST-02 ST-03 ST-04 ST-05 ST-06 ST-07A ST-08 ST-09 ST-10 ST-11 ST-12 ST-13 ST-14 ST-15 ST-16 St-17 ST-18 ST-19 ST-20 ST-2f ST-22 ST-23

. ST-24 ST-33 ST-34 ST-35 ST-36 ST-37 ST-38 Mean+/-s.d.

Control 1 Control2 1st Ouarter U/31/95 3/31/96 4.6+/-0.6 11.1+/- 0.6 15.0+/- 0.1 12.1+/- 0.6 12.2+/-0.6 12.0+/- 0.6 11.8+/- 0.6 10.7+/- 0.6.

10.9+/- 0.6 11.0+/- 0.6 10.7+/- 0.1 13.1+/- 0.6 11.6+/- 0.6 11.0+/- 0.1 9.1+/- 0.6 9.4+/- 0.6 11.0+/- 0.6 10.2+/- 0.6 10.9+/- 0!6 11.7+/- 0.6 11.0+/- 0.1 10.1+/-0.6' 5.4+/- 0.6 11.3+/- 0.7 10.1+/- 0.6 10.2+/- 0.6 10.9+/- 0.6 12.5+/- 0.6 10.4+/- 0.6 11.4+/-0.6 10.2+/- 0.6 11.0+/-1.5 5.2+/- 0.6 5.3+/- 0.6 2nd Ouarter 3/31/96 7/1/96 3.8 +/-0.6 11.8+/- 0.6 15.4+/- 0.6 12.7+/- 0.6 13.4+/- 0.6 13.8+/- 0.6 11.1+/- 0.6 12.2+/- 0.6 10.6+/- 0.6 10.5+/- 0.6 11.5+/- 0.6 15.3+/- 0.6 13.1+/- 0.6 11.8+/- 0.6 10.3+/- 0.6 11.1+/- 0.6 11.0+/- 0.6 10.4+/- 0.6 11.4+/- 0.6.

11.8+/- 0.6 11.0+/- 0.6 9.9+/- 0.6 5.1+/- 0.6 12.1+/- 0.6 11.6+/- 0.6 10.6+/- 0.6 10.9+/- 0.6 11.8+/- 0.6 10.9+/- 0.6 11.5+/- 0.6 10.8+/- 0.6 11.6 +/- 1.7 5.8+/- 0.6 5.8+/- 0.6

  • Intransite exposure has been subtracted from result.

3-1 3rd Ouarter 7/1/96 9/'19/96 5.9+/-0.6 12.5+/- 0.6 18.8+/- 0.6 14.9+/- 0.6 14.7+/- 0.6 14.2+/- 0.6 13.4+/- 0.6 12.0+/- 0.6 12.4+/- 0.6 12.0+/- 0.6 11.3+/- 0.6 14.8+/- 0.7 12.8+/- 0.6 12.1+/- 0.6 10.1+/-0.7 11.1+/- 0.7 11.6+/- 0.6 11.3+/- 0.6 12.1+/- 0.6 13.0+/- 0.6 12.5+/- 0.6 11.2+/- 0.6 5.5+/- 0.6 13.3+/- 0.6 11.6+/- 0.6 10.7+/- 0.6 11.9+/- 0.6 13.6+/- 0.7 11.3+/- 0.6 12.4+/- 0.6 10.8+/- 0.6 12.3 +/- 2.1 4.7+/- 0.6 4.7+/- 0.6 4th Ouarter 9/'29/96 1/2/'17 4.8 +/- 0.6 12.6+/- 0.6 16.1+/- 0.6 14.2+/- 0.6 14.5+/- 0.6 14.5+/- 0.6 12.5+/- 0.6 12.1+/- 0.6 12.5+/- 0.6 10.5+/- 0.6 12.0+/- 0.6 15.0+/- 0.6 13.8+/- 0.6 12.1+/- 0.6 10.4+/- 0.6 11.7+/- 0.6 10.8+/- 0.6 10.9+/- 0.6 11.6+/- 0.6 12.0+/- 0.6.

11.1+/- 0.6 10.5+/- 0.6 5.1+/- 0.6 12.2+/- 0.6 11.5+/- 0.6 10.8+/- o;6 10.8+/- 0.6 12.6+/- 0.6 11.0+/- 0.7 11.4+/- 0.6 11.1+/- 0.6 12.0+/- 1.9 5.7+/- 0.6 5.7+/- 0.6

PALISADES Table 4.

Gamma Radiation, as measured by 11.Ds, annual exposure.

Units: mR/365 days rwK

.1226 Date Placed U/31/95 Date Removed 1n.1'11 Intransit (mR) 3.2+/- 2.4 ST-01 43.8+/- 2.4 ST-02 60.8+/- 2.4 ST-03 51.2+/- 2.4 ST-<>4 54.0t 2.4 ST-05 53.2+/- 2.4 ST-06 47.6+/- 2.4 ST-07A 47.S+/- 2.4 ST-08 46.6+/- 2.4 ST-09 43.6+/- 2.4 ST-iO 43.0+/- 2.4 ST-11 56.0+/- 2.4 ST-12 50.0+/- 2.4 ST-13 43.7+/- 2.4 ST-14 38.S+/- 2.4 ST-15 41.1+/- 2.S ST-16 41.1+/- 2.4 St-17 41.0+/- 2.4 ST-18 44.0+/- 2.4 ST-19 47.S+/- 2.4 ST-20 433+/- 2.4 ST-21 44.2+/- 2.4 ST-22 22.0+/- 2.4 ST-23 49.S+/- 2.4 ST-24 43.8+/- 2.4 ST-33 39.8+/- 2.4 ST-34 40.4+/- 2.4 ST-35 51.8+/- 2.4 ST-36 403+/- 2.4 ST-37 42.1+/- 2.4 ST-38 40.6+/- 2.4 Mean+/-s.d.

4.5.1+/-6.9 Control 1 213+/- 2.4 Control2 213+/- 2.4

  • Intransite exposure has been subtracted from result.

4-1

PALISAQES Tables.

Lake Water, analyses for gross alpha, gross beta and tritium.

Coll~tion:

Monthly composites of daily collections Units:

pCi/L Location:

Discharge lab Code Required LLDs PALW-711 PALW-1212 PALW-2053 Date Collected 2/5/96 2/29/96 3/31/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Alpha 1.0

<0.6

<0.9

< 1.0 Gross Beta 4.0 2.0+/-0.4 2.6+/-0.6 1.9+/-0.8 H-3 500

< 147

<188

< 190 Lab Code Required LLDs PALW-3030 PALW-3687 PALW-4533 Date Collected 4/~/96 5/31/96 6/'!JJ/96 Date Received 5/14/96 6/11/96 7/11/96 Gross Alpha 1.0

<1.0

<0.7

<0.8 Gross Beta 4.0 2.8+/-0.6 2.5+/-0.5 2.4+/-0.6 H-3 500 1912+/- 138

<163

<158 Lab Code Required LLDs PALW-5729 PALW-6184 PALW-7120 Date Collected 7/31/96 9/3/96 9/~/96 Date Received 8/'l3/96 9/10/96 10/11/96 Gross Alpha 1.0

<0.6

<0.7

<0.9 Gross Beta 4.0 2.2+/-0.5 2.0+/-0.5 2.6+/-0.6

. H-3 500 7537+/-238 3613+/- 181

< 157 Lab Code Required LLDs PALW-8083 PALW-8828 PALW-9638 Date Collected 11/4/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/'17 Gross Alpha 1.0

<0.6

<0.7

<0.7 Gross Beta 4.0 2.5+/-0.5 2.5+/-0.7 2.2+/-0.5 H-3 500

< 152 29720+/-467 100+/- 127 5-1

PALISADES Table 5.

LaJce water, analyses for gross alpha, gross beta and bitium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Intake lab Code Required LLDs PALW-7C1J, 10 PALW-1211 PALW-2052 Date Collected 2/5/96 2/29/96 3/31/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Alpha 1.0

<0.S

<0.9

<0.S Gross Beta 4.0 1.8+/- 0.3 2.4+/-0.6 2.5+/- 0.4 H-3 500

< 147

<188

< 190 lab Code Required LLDs PALW-3029 PALW-3686 PALW-4532 Date Collected 4/'.ll/96 5/31/96 6/'.ll/96 Date Received 5/14/96 6/11/96 7/11/96 Gross Alpha 1.0

<0.1

<0.S

<0.1 Gross Beta 4.0 2.4+/-0.4 1.6+/-0.S 1.6+/-0.6 H-3 500

<167

<163

<158 lab Code Required LLDs.

PALW-5128 PALW-6183 PALW-7118, 9 Date Collected

  • 7/31/96 9/3/96 9/'.ll/96 Date Received 8/'lJ/96 9/10/96 10/11/96 Gross Alpha 1.0

<0.1

<0.1

'<0.6 Gross Beta 4.0 2.1+/-0.S 1.8+/-0.4 1.8+/-0.4 H-3 500

<149

<166

<156 LabCode '

Required LLDs PALW-8082 PALW-8821 PALW-9637 Date Collected 11/4/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/'11 Gross Alpha 1.0

<0.6

<0.6

<0.1 Gross Beta 4.0 2.2+/-0.4 2.4+/-0.1 2.6+/-0.S H-3

' 500

< 153

<158

<181 5-2

PALISADES Table6.

Lake water, drinking, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

South Haven Municipal System (Raw)

Lab Code Date Collected Date Received Gross Beta LabCOde Date Collected Date Received Gross Beta Lab Code Date Collected Date Received Gross Beta lab Code Date Collected Date Received Gross Beta Req~LLDs 4.0 Required LLDs 4.0 Required LLOs

"~P Required LLOs 4.0 PALW~9 1/31/96 2/9/96 2.5+/-0.8 PALW-2862 4/'!il/96 5/9/96 7.7+/- 1.1 PALW-5436 7/31/96 8/12/96 2.0+/-0.5 PALW-8086 11/6/96 11/11/96 1.7+/-0.8.

6-1 PALW-1215 2/29/96 3/11/96 1.8+/-0.6 PALW-3591 5/31/96 6/6/96 2.0+/-0.6 PALW-6231 8/31/96 9/13/96 2.1+/-0.6 PALW-8701 11/'!il/96 12/5/96 2.2+/-0.7 PALW-2094 3/31/96 4/15/96 1.8+/-0.6 PALW-4534 6/'!il/96 7/11/96 1.9+/-0.6 PALW-7121 9/'!il/96.

10/11/96 2.1+/- 0.3 PALW-272 1/1JJ/97 1/'Zl/97 2.0+/-0.6

PALISAQES Table6.

Lake water, drinking, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/l Location:

South Haven Municipal System (Treated)

LabC.ode Required LLDs PALW-640 PALW-1216 PALW-2095 Date Collected 1/31/96 2/'29/96 3/31/96 Date Received 2/9/96 3/11/96 4/15/96 Gross Beta 4.0 2.6+/-0.8 1.8+/-0.6

. 2.6+/-0.6 H-3 500

<147

<184

<190 lab Code Required LLDs PALW-2863 PALW-3592 PALW-4535 Date Collected

. 4/30/96 5/31/96 6/30/96 Date Received 5/9/96 6/6/96 7/11/96 Gross Beta 4.0 6.1+/- 1.0 1.4+/-0.6 2.0+/-0.6 H-3 500

<149

<159

<158 LabCode Required LLDs PALW-5437 PALW-6232 PALW-7122 Date Collected 7/31/96 8/31/96 9/30/96 Date Received 8/12/96 9/13/96 10/11/96 Gross Beta 4.0 1.1+/-0.6

. 3.0+/-0.8 2.0+/-0.4 H-3 500

<151

<167

<156 LabC.ode

. Required LLDs PALW.:SOSS PALW-8702 PALW-211*

Date Collected 11/6/96 11/30/96 1/'1JJ/'11 Date Received 11/11/96 ll/5/96 1/'zl/'11 Gross Beta 4.0 2.1+/-0.6 2.3+/-0.7 2.0+/-0.6 H-3 500

<152

<158

<163 6-2

PALISADES Table7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Site Wells No. 2 and 3 (Domestic) lab Code Required LLDs PAWW-714 PAWW-1218 PAWW-2056 Date Collected 2/5/96 2/'29/96 3/31/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Beta 4.0

< 1.4 1.2+/-0.6 1.3+/- 0.5 H-3 500

<188

<188

< 190 lab Code Required LLDs PAWW-3034 PAWW-3690 PAWW-4536 Date Collected 4/'!JJ/96 5/31/96 6/'!JJ/96 Date Received 5/14/96 6/11/96 7/11/96 Gross Beta 4.0 6.0+/- 1.1

< 1.0 1.6+/- 0.7.

H-3 500

<167 198+/-89

<158 Lab Code Required LLDs PAWW-5732 FAWW-6181, 2 PAWW,*7125 Date Collected 7/31/96 9/3/96 9/'JIJ/96 Date Received 8/'ZJ/96 9/10/96 10/11/96 Gross Beta 4.0 1.7+/-0.5 1.3+/-0.4 1.2+/-0.6 H-3 500 155+/-80

< 1(,6

< 157 lab Code Required LLDs PAWW-8080 PAWW-8826 PAWW-9639 Date Collected 11/4/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/<Jl Gross Beta 4.0 1.5+/-0.6

< 1.2 2.9+/-0.7 H-3 500

<152

<158

< 181 7-1

PAI ISAOES Table 7.

Well water, analyses for gross beta and bitium.

Collection:

Monthly composites of daily collections Units:

pCi/L LoCation:

State Park Lab Code Required LLDs PAWW-164 PAWW-641 PAWW-1219 Date Collected 1/9/96 2/7/96 3/6/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0

< 1.2

< 1.0

<0.9 H-3

.500

<157

<146 177+/- 83 Lab Code Required LLOs PAWW-2057 PAWW-2864 PAWW-3593 Date Collected 4/11/96 5/7/96 6/4/96 Date Received 4/12/96 5/9/96 6/6/96 Gross Beta 4.0

< 1.0 4.4+/- 1.0 4.0+/-0.7 H-3

.500

<150

-<158

<159 Lab Code Required LLDs PAWW-4538 PAWW-5438 PAWW-6233 Date Collected 7/10/96 8/9/96 9/10/96 Date Received 7/11/96 8/12/96 9/13/96.

Gross Beta 4.0 3.1+/-0.6 3.3+/-0.5 3.1+/-0.6 H-3

.500

<150

<148

<166 Lab Code Required LLDs PAWW-7131 PAWW-8075 PAWW-8700 Date Collected 10/7/96 li/6/96 12/3/96 Date Received 10/11/96 11/6/96 12/5/96 Gross Beta 4.0 2.2+/-0.4

< 1.6

. < 1.3 H-3

.500

<157 161+/-83

<158 7-2

PALISADES Table 7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Township Park lab Code Required LLDs PAWW-165 PAWW-642 PAWW-1220 Date Collected 1/8/96 2/7/96 3/5/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0 2.2+/-0.7 1.9+/-05 1.3+/-0.6 H-3 500

<157

<188

< 152 lab Code Required LLDs PAWW-2058 PAWW-2865 PAWW-3594 Date Collected 4/10/96 5/8/96 6/3/96 Date Received 4/12/96 5/9/96 6/6/96 Gross Beta 4.0 1.6+/-0.6' 6.5+/- 1.1 15+/-0.6 H-3 500

< 150

<166

<159 lab Code Required LLDs PAWW-4539 PAWW-5439 PAWW-6234 Date Collected 7/10/96 8/8/96 9/10/96 Date Received 7/11/96 8/12/96 9/13/96 Gross Beta 4.0 1.9+/-0.7 2.1+/-05 3.3+/-0.9 H-3 500

< 150

<148

<166 LabCode Required LLDs PAWW-7132 PAWW-8076 PAWW-8703 Date Collected 10/7/96

.11/6/96 12/4/96 Date Received 10/tt/96 11/11/96 12/5/96 Gross Beta 4.0 2.2+/-0.6 2.6+/-0.8 1.9+/-0.7 H-3 500

<157

<153

<162 7-3

PALISADES Table 7.

Well water, analyses for gross beta and tritium.

Collectian:

Monthly composites of daily collections Units:

pCi/L Location:

Warehouse (Site Well #7)

LabCode Required LLDs PAWW-166 PAWW-643 PAWW-1221 Date Collected 1/9/96 2/7/96 3/6/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0 6.6+/- 1.6 5.7+/- 1.3 6.1+/-0.8 H-3 500

<157

<146 175+/- &1 Lab Code Required LLDs PAWW-2059 PAWW-2866, 7 PAWW-3595 Date Collected 4/10/96 5/7/96 6/4/96 Date Received 4/12/96 5/9/96 6/6/96 Gross Beta 4.0 55+/- 1.4 6.9+/- 1.0 5.7+/- 1.4 H-3 500

<151

<161

<153 Lab Code

. Required LLDs PAWW-4540 PAWW-5504 PAWW-6235 Date Collected 1/9/96 8/12/96 9/9/96 Date Received 7/11/96 8/14/96 9/13/96 Gross Beta 4.0 4.4+/-0.8 5.7+/- 1.2 5.9+/- 1.3 H-3 500

<158

<150

<166 lab Code Required LLDs PAWW-7126 PAWW-8077 PAWW-8699 Date Collected 10/7/96 11/6/96 12/3/96 Date Received 10/11/96 11/11/96 1215/96

  • Gross Beta 4.0 6.3+/- 1.4 5.5+/-2.4 6.6+/- 1.6 H-3 500

<157

<153

< 162 7-4

PALISAQES Table 7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units":

pO/L Location:

Outage Buildings (Site Wells #11, 12 and 13)

Lab Code Required LLDs PAWW-167 PAWW-644 PAWW-1222 Date Collected 1/9/96 2/7/96

'3/6/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0

< 0.8 1.0+/-0.5 0.9+/-0.5 H-3 500

<200

<146 180+/-83 Lab Code Required LLDs PAWW-2060 PAWW-2868 PAWW-3596 Date Collected 4/10/96 5/7/96 6/4/96 Date Received 4/12/96 5/9/96 6/6/96 Gross Beta 4.0

<0.9 1.0+/-0.5 1.1+/-0.5 H-3 500

<150

<153

<159 lab Code Required LLDs.

PAWW-4541 PAWW-5505 PAWW-6236 Date Collected 7/9/96 8/12/96 9/9/96 Date Received 7/11/96 8/14/96 9/13/96 Gross Beta 4.0 0.9+/-0.6 1.2+/-0.5

< 1.3 H-3 500

<150

<150

<162 Lab Code Required LLDs PAWW-7127 PAWW-8078 PAWW-8698 Date Collected 10/7/96 11/6/96 12/3/96 Date Received 10/11/96 11/11/96 12/5/96 Gross Beta 4.0 1.3+/-0.5

< 1.3

< 1.1 H-3 500

<157

<153

<162 7-5

PALISAQES Table 7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Site Well #14

,LabCode Required LLDs PAWW-168 PAWW-645 PAWW-1223 Date Collected 1/9/96 2/7/96 3/6/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0 32.8 +/-2.fl 6.9+/-0.8 10.4+/-1.(f H-3 500

<157

<146

< 152 lab Code Required LLDs PAWW-2061 PAWW-2869 PAWW-3597, 8 Date Collected 4/10/96 517/96 6/4/96 Date Received 4/12/96 5/9/96 6/6/96

  • Gross Beta 4.0 1.1+/-3.3

'5.1+/-2.0 2.2+/-0.S H-3 500

< 151

<153

<153 LabCode Required LLDs PAWW-4542 PAWW-5506.

PAWW-6237 Date Collected 7/9/96 8/12/96 9/9/96 Date Received

' 7/11/96 8/14/96 9/13/96 Gross Beta 4.0 1.7+/-0.6 1.2+/-0.S

< 1.3 H-3 500

<150

<148

<166 lab Code Required LLDs '

PAWW-7128 PAWW-8203 PAWW-8695 Date Collected 10/7/96 11/8/96 1213/96 Date Received 10/11/96 11/12/96

' 12/5/96 Gross Beta 4.0 2.3+/-0.6 3.1+/-0.7 11.8+/- 1.1 H-3 500

<157

<153

< 162 7-6

PALISADES Table 7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Site Weli #15 LabCode Required LLDs PAWW-169 PAWW-646 PAWW-1224 Date Collected 1/9/96 2/7/96 3/6/96 Date Received 1/12/96 2/9/96 3/11/96 Gross Beta 4.0 6.6+/-0.8 6.2+/-0.8 8.3+/- 0.8 H-3 500

<157

<146

< 152 LabCode Required LLDs PAWW-2062 PAWW-2870 PAWW-3599 Date Collected 4/10/96 5/7/96 6/4/96 Date Received 4/12/96 5/9/96 6/6/96 Gross Beta 4.0 6.5+/-0.8 8.0+/-0.9 6.7+/-0.9 H-3 500.

< 151

<153

<153 Lab Code Required LLDs PAWW-4543

  • PAWW-5507 PAWW-6238 Date Collected 7/9/96 8/12/96*

9/9/96 Date Received 7/11/96 8/14/96 9/13/96 Gross Beta 4.0 5.9+/-0.8 8.2+/-0.9 5.5+/- 1.1 H-3 500

<150

<:148

<162 Lab Code Required LLDs PAWW-7129 PAWW-8120 PAWW-8696 Date Collected 10/7/96 11/6/96 12/3/96 Date Received 10/11/96 11/11/96

  • 12/5/96 Gross Beta 4.0 7.1+/-0.9 8.0+/-0.9 10.5+/- 1.2 H-3 500

<157

<153

<162

PALISADES.

Table 7.

Well water, analyses for gross beta and tritium.

Collection:

Monthly composites of 4aily collections Units:

pCi/L Location:

Site Well #16 lab Code Required LLOs Date Collected Date Received Gross Beta 4.0 H-3 500 lab Code Required LLOs Date Collected Date Received Gross Beta 4.0 H-3 500 Lab Code Required LLOs Date Collected Date Received Gross Beta H-3 Lab Code Date Collected Date Received Gross Beta H-3 4.0 500 Required LLDs 4.0 500 PAWW-170 1/9/96 1/12/96 6.9+/- 1.0

<157 PAWW-2063, 4 4/10/96 4/12/96 6.3+/-0.6

<151 PAWW-4544 7/9/96 7/11/96 4.3+/-0.8

<150 PAWW-7130 10/7/96 10/11/96 6.1+/-0.8

<151

  • Action required if gross beta exceeds 10 pCi/L PAWW-647 2/7/96 2/9/96 5.7+/-0.7

<146 PAWW-2871 5/7/96 5/9/96 5.3+/-0.7

<153 PAWW-5508 8/12/96 8/14/96 3.9+/-0.7

<150 PAWW-8121, 2 11/6/96

.11/11/96 5.1+/-0.5

<153 PAWW-1225 3/6/96 3/11/96 4.6+/-0.7

<152 PAWW-3600 6/4/96 6/6/96 4.8+/-0.7 168+/-83 PAWW-6239 9/9/96 9/13/96 5.1+/-0.8

<166 PAWW-8697 12/3/96 12/5/96 6.5+/-0.9

<162 b Results of subsequent analyses are: I<..W = 1284+/-3 pCi/L; CD-(,()= <2.2 pCi/L; Cs-134 = <3.8 pCi/L; Cs-137 = <1.5 pO/L c Results of subsequent analyses are: I<..W = <78.5 pCi/L; CD-(,()= <4.1 pCi/L; Cs-134 = <4.5 pCi/L; Cs-137 = <4.1 pO/L 7-8

PALISADES Table8.

Water, Ludington controls, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Ludington (take In)

LabCode Required LLDs PALW-712 PALW-1213, 4 PALW-2054 Date Collected 2/5/96 3/5/96 4/2/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Beta 4.0 1.8+/-0.8 2.5+/-0.4 1.3+/- 0.6 H-3 500

<147

<188

<152 lab Code Required LLDs PALW-3001 PALW-3688 PALW-4580 Date Collected 5/8/96 6/3/96.

7/2/96 Date Received 5/14/96 6/11/96 7/12/96 Gross Beta 4.0 7.6+/- 1.1 2.0+/-0.6 2.4+/-0.7 H-3 500

<166

<163

. <157 LabCode Required LLDs PALW-5730 PALW-6179 PALW-7123 Date Collected 7/31196 9/3/96 10/3/96 Date Received 8/'1.3/96 9/10/96 10/11/96 Gross Beta 4.0 2.0+/-0.6 2.4+/-0.6 2.2+/-0.4 H-3 500 163+/-81

<163

<156 LabCode Required LLDs PALW-8084 PALW-8930 PALW-9640

  • Date Collected 11/4/96 12/3/96 12/31/96 Date Received 11/11/96 12/11/96 1/10/'11 Gross Beta 4.0 3.0+/-0.6 2.4+/-0.7 2.2+/-0.6 H-3 500

<152

<158

< 181 8-1

PALISADES Table8.

Water, Ludington controls, analyses for gross beta and tritium.

Collection:

Monthly composites of daily collections Units:

pCi/L Location:

Ludington (Well Water) lab Code Required LLDs PAWW-713 PAWW-1217 PAWW-2055 Date Collected 2/5/96 3/5/96 4/2/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Beta 4.0

<0.9

<0.9

<0.9 H-3 500

<147

<188

<189 Lab Code Required LLDs PAWW-3002, 3 PAWW-3689 PAWW-4537 Date Collected 5/8/96 6/3/96 7/2/96 Date Received 5/14/96 6/11/96 7/11/96 Gross Beta 4.0 3.1+/-0.5

< 1.1 1.3+/-0.6 H-3 500

<166

<163

<158 Lab Code Required LLDs PAWW-5731 PAWW-6178 PAWW-7124 Date Collected 7/31/96 9/3/96 10/3/96 Date Received 8/'lJ/96 9/10/96 10/11/96 Gross Beta 4.0

< 1.0 1.0+/-0.5

< 0.5 H-3 500 169+/-81

<166

<157 lab Code Required LLDs PAWW-8079 PAWW-8829 PAWW-9641 Date Collected 11/4/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/97 Gross Beta 4.0 0.9+/-0.4

< 1.2 1.4+/-0.6 H-3 500 164+/-83

<158

< 181 8-2

PALISAQES Table 9.

In-Plant water, analyses for gross alpha, gross beta, strondwn 89, strontium 90, tritium and gamma-emitdng isotopes.

Collection:

Monthly composites, 1996 Units:

uO/mL Location Service Water lab Code Required LLDs PACW-708 PACW-1210 PACW-2051 Date Collected 2/5/96 2/'19/96 3/31/96 Date Received 2/14/96 3/11/96 4/12/96 Gross Alpha 1.0 E-09

<4.9E-10

<6.2E-10

<4.9E-10 Gross Beta 1.0 E-09 1.8E-9 +/- 3.9E-10 2.lE-9+/-4.lE-10 2.2E-9 +/- 4.8E-10 H-3 5.0 E-07

< 1.SE-7

< 1.9E-7

< 1.9E-7 Sr-89 5.0E-09

<6.8E-10

<8.0E-10

<9.SE-10 Sr-90 1.0E-09 6.0E-10+/- 2.7E-10 6.lE-10+/-3.4£-10 4.6E-10 +/- 2.SE-10 Othen 1.0 E-<11

<2.4E-9

<2.6E-9

<2.9E79 Cs-137 1.0 E-<11

<2.8E-9

<2.7E-9

< 1.9E-9 lab Code Required I.U?s PACW-3028 PACW-3685 PACW-4531 Date Collected 4/30/96

. 5/31/96 6/30/96 Date Received 5/14/96 6/11/96 7/11/96 Gross Alpha 1.0E-09

<8.SE-10 7.1E-10+/-4.3E-10

<8.9E-10 Gross Beta 1.0 E.()IJ 2.4E-9 +/- 6.0E-10 2.SE-9 +/- 4.8E-10 1.8E-9 +/- 5.SE-10 H-3 5.0E-07

< 1.SE-7

< 1.6E-7

< 1.6E-7 Sr-89 5.0E-09

<6.9E-10

<8.0E-10

<6.8E-10 Sr-90 1.0 E-09 5.sE-10+/-3.0E-10. 5.SE-10 +/- 3.0E-10 9.5E-10+/-3.2E-10 Othen 1.0 E-<11

<3.3E-9

<2.SE-9

<4.6E-9 Cs-137 1.0E41

<4.3E-9

<4.SE-9

<6.0E-9 9-1

PALISAQES Table9.

In-Plant water, analyses for gross alpha, gross beta, strontium 89, strontium 90, tritium and gamma-emitting isotopes.

Collection:.

Monthly composites, 1996 Units:

uO/mL UibCode Required LLDs PACW-5727 PACW-6180 PACW-7117 Date Collected 7/31/96 9/3/96 9/30/96 Date Received 8/'l.3/96 9/10/96 10/11/96 Gross Alpha to E-09

<6.9E-10 1.lE-9+/-5.lE-10

<7.9E-10 Gross Beta 1.0 E-09 2.2E-9 +/- 4.7E-10 2.4E-9 +/- 4.7E-10

  • 2.6E-9 +/- 5.6E-10 H-3 5.0E-07

<1.SE-7

< 1.7E-7

< 1.6E-7 Sr-89 5.0 E-09.

<1.4E-9

' < 1.2E-9

< 1.SE-9 Sr-90 1.0 E-09 7.6E-10+/- 3.2E-10 8.3E-10 +/- 4.0E-10

<5.9E-10 Others 1.0 E.al

<3.9E-9

<2.8E-9

<2.0E-9 Cs-137 1.0 E.al

<2.lE-9

<2.2E-9

<6.2E-9 lab Code Required LLDs PACW-8081 PACW.:SS25 PACW-9636 Date Collected 11/4/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/'11 Gross Alpha 1.0 E-09

<4.lE-10

<6.7E-10*

<5.7E-10 Gross Beta LOE-09

. 2.2E-9 +/- 3.sE-10 2.2E-9 +/- 4.5E-10

. 2.4E-9 +/- 4.7E-10 H-3 5.0E-07 2.lE-7 +/- 8.5E-8

<1.6E-7

< 1.8E-7 Sr-89 5.0E-09

<9.9E-10

<9.6E-10

<7.2E-10 Sr-90 LOE-09

<4.4E-10 7.0E-10+/-3.2E-10

<7.lE-10 Others 1.0 E.al *

<2.8E-9

~3.8E-9

<1.9E-9 Cs-137 1.0 E.al

<5.2E-9

<4.8E-9

<4.9E-9 9-2

PALISAQES Table 9.

In-Plant water, analyses for gross alpha, gross beta, strontium 89, strontium 90, tritium and gamma~mitting isotopes.

Collection:

Monthly composites, 1996 Units:

uO/mL Location Turbine Sump LtbCode Required LLDs PACW-847 PACW-1358 PACW-3167 Date Collected 1/31/96 2/'J!J/96 3/31/96 Date Received 2/'ll/96 3/18/96 5/'ll/96 Gross Alpha 1.0 E-09 2.6E-10+/- 1.9E-10

<3.sE-10

<6.0E-10 Gross Beta 1.0 E-09 5.7E-9 +/- 4.SE-10 1.6E-9 +/- 4.0E-10 1.3E-9 +/- 5.3E-JO H-3 5.0 E-0'1 4.4E-6+/- 1.9E-7 3.4E-6 +/- 1.9E-7 5.3E-6+/- 2.lE-7 Sr-89 5.0 E-09

<7.BE-10

<6.i'E-10

<9.0E-10 Sr-90 1.0 E-09

<4.lE-10

<3.8E-10 6.9E-10 +/- 3.3E-10 Others 1.0.E.al

<3.SE-9

<3.i'E-9

<3.0E-9 Cs-137 1.0 E.al

<4.6E-9

<3.0E-9

<2.i'E-9 LtbCode Required LLDs PACW-3168 PACW-3767 PACW-4579 Date Collected 4/30/96 5/31/96 6/30/96 Date Received 5/'ll/96 6/14/96 7/12/96 Gross Alpha 1.0 E-09

<5.4E-10

<4.6E-10

<5.2E-10 Gross Beta 1.0 E-09 1.1E-9+/-4.9E-10 6.SE-10+/-4.lE-10 1.lE-9 +/- 5.3E-10 H-3 5.0 E-0'1

  • 5.lE-6 +/- 2.lE-7 6.7E-6 +/- 2.4E-7 6.i'E-6+/- 2.3E-7 Sr-89 5.0E-09

<7.i'E-10

<8.6E-10

<6.8E*10 Sr-90 1.0 E-09 4.3E-10+/-2.5E-10

<4.0E-10

<4.lE-10 Others 1.0 E..QI

< 1.9E-9

<1.9E-9

<2.3E-9 Cs-137 1.0 E.QI

<4.2E-9

<5.0E-9

< 1.9E-9 9-3

PALISADES Table9.

In-Plant water, analyses for gross alpha, gross beta, strontium 89, ~trontium 90, tritium and gamma-emitting Isotopes.

Collection:

Monthly composites, 1996 Units:

uO/mL LabCode Required LLOs PACW-5716 PACW~240

  • PACW-7116 Date Collected 7/31/96 8/31/96 9/30/96 Date Received 8/'Zl/96 9/13/96 10/11/96 Gross Alpha 1.0 E-09

<8.0E-10

<8.0E-10

<2.3E-10 Gross Beta 1.0 E-09 2.7E-9 +/- 6.SE-10 1.sE-9 t 6.9E-10

6. lE-10 +/- 3.6E-10 H-3 5.0 E-0'1 1.6£-3 +/- 3.3E~

1.2E-5 t 3.0E-7 5.3E~t 2.lE-7 Sr-89 5.0 E-09

<7.SE-10

<9.8£-10

< 1.3E-9 Sr-90 1.0 E-09

<3.4E-10

<4.9E-10

<4.9£-10 Othen 1.0E~

<2.8E-9

<2.3E-9

<1.9E-9 Cs-137 1.0E~

<3.3E-9

<4.lE-9 *.

<8.2E-9 lab Code Required LLOs PACW-8087 PACW-8830, 1 PACW-9635 Date Collected 10/31/96 11/30/96 12/31/96 Date Received 11/11/96 12/10/96 1/10/'11 Gross Alpha

.1.0 E-09

<7.4E-10*

<4.0E-10

<4.2E-10 Gross Beta t.o E-09 1.2E-9+/- 5.0E-10 1.1E-8+/-4.3E-10

. 1.7E-9+/-:4.4E-10 H-3 5.0 E-01 4.7E~+/- 2.QE-7 2.lE~+/- 1.0E-7 3.0E~+/- 1.7E-7

.Sr-89 5.0 E-09

< 1.0E-9

<5.9E-10

<7.SE;.10 Sr-90 1.0 E-09

<6.6E-10

<6.3E-10

<6.0E-10 Othen 1.0 E.al

<4.5E-9

<2.8E-9

<4.0E-9 Cs-137 1.0E~

<3.7E-9

< 1.0E-8

<7.0E-9 9-4

PALISADES Table 10.

Mille, analyses for iodine-131 and gamma~mitting isotopes.

Collection:

Monthly Units:

pCi/L Location:

DC-Danny Carpenter Farm lab Code Required LLDs PAMI-161 PAMI-6.37 PAMI-1154 PAMI-2048 Date Collected 1/9/96 2/7/96 3/6/96 4/11/96 Date Received 1/12/96 2/9/96 3/8/96 4/12/96 I-131 1.0

<0.4

<0.3

<0.4

<0.3 K-40 1200+/- 100 1300+/- 100 1330+/-90 1410+/- 110 Cs-134 15.0

<4.3.

<3.4

<5.1

<4.5 Cs-137 18.0

<4.1

<4.2

<3.9

<4.6 Ba-La-140 15.0

<2.3

<3.3

<9.9

< 1.6 lab Code Required LLDs PAMI-2848 PAMI-3584 PAMI-4524 PAMI-5435 Date Collected 5/7/96 6/4/96 7/10/96 8/9/96 Date Receiv'ed 5/9/96 6/6/96 7/11/96 8/12/96 1-131 1.0

<0;3

<0.3

<0.4

<0.4 K-40 1510+/- 160 1360+/-110 1450+/- 160 1370+/- 140 Cs-134 15.0

<7.5

<4.1

<3.0

<5.7 Cs-137 18.0

<7.1

<2.9

<6.4

<4.0 Ba-La-140 15.0

<9.1

<4.1

<6.6

<2.5 lab Code Required LLDs.

PAMI-6189 PAMI-7085 PAMI-8117 PAMI-8686 Date Collected 9/10/96 10/8/96 11/6/96 12/3/96 Date Received 9/11/96 10/11/96 11/11/96 12/5/96 1-131 1.0

<0.4

<0.5

<0.5

<0.4 K-40 1270+/- 140 1350+/- 140 1290+/- 150 1350+/- 120 Cs-134 15.()

<5.6

<6.6

<5.9

<5.0 Cs-137

.18.0

<1.3

<5.4

<4.8

<4.7 Ba-La-140*

15.0

<6.0

<4.0

<4.4

<3.2 10-1

PALISADES Table 10.

Mille, analyses for iodine-131 and gamma-i!mitting isotopes.

Collection:

Monthly Units:

pCi/L Location:

KK-Kenneth Kemp Fann Lab Code Required LLDs PAMI-163 PAMI-638 PAMI-1152, 3 PAMI-2047 Date Collected 1/10/96 216/96 3/5/96 4/9/96 Date Received 1/12/96 2/9/96 3/8/96 4/12/96 1~131 1.0

<0.3

<0.3

<0.4

<0.4 K-40 1240+/-200 1380+/-120

. 1440+/- 120 1450+/- 110 Cs-134 15.0

<2.7

<6.1

<2.7

<2.9 Cs-137 18.0

<5.5

<5.2

<5.5

<4.6 Ba-La-140 15.0

<8.3

<5.9

<4.2

<4.0 Lab Code Required LLDs PAMI-2846 PAMI-3583 PAMI-4521 PAMI-5432 Date Collected 5/6196 6/3/96 7/9/96 8/8/96 Date Received 5/9/96 6/6/96 7/11/96

. 8/12/96 1-131 1.0

<0.3

<0.4

<0.3

<0.2 K-40 1290+/-150 1400+/-110 1610+/- 190 1300+/- 110 Cs-134 15.0

<7.1

<3.5

<8.6

<4.9 Cs-137 18.0

<7.6

<4.4

<4.8

<5.6 Ba-La-140 15.0

<8.3

<3.0

<4.6

<3.0 LabCode Required LLDs PAMI-6187 PAMJ:i.6999 PAMl-8119 PAMI-8685 Date Collected 9/9196 10/7/96 11/6/96 12/2/96 Date Received 9/11/96 10/9/96 11/11/96 12/5/96 1-131 1.0

<0.4

<0.4

<0.4

<0.4.

K-40 1310+/-120 1340+/-180 1300+/- 170 1420+/- 160 Cs-134 15.0

<3.8

<6.6

<3.6

<3.1 Cs-137 18.0

<5.0

<9.0

<3.5

<5.3 Ba-La-140 15.0

<6.2

<4.8

<4.9

<7.3 10-2

PALISAQES Table 10.

Mille, analyses for iodin~131 and gamma-emitting isotopes.

Collection:

Monthly Units:

pCi/L Loca.tion:

TA-Tom Anderson Fann lab Code Required LLDs PAMI-t<U PAMI-6.36 PAMI-1155 PAMI-2050 Date Collected 1/9/96 2/7/96 3/6/96 4/11/96 Date Received 1/12/96 2/9/96 3/8/96 4/12/96 1-131 1.Q

<0.4

<0.3

<0.4

<0.3 '

K-40 1370+/- 140 1290+/- 140 1250+/-90 1140+/- 150 Cs-134 15.0

<4.2

<4.4

<4.0

<S.O Cs-137 18.0

<4.9

<5.1

<4.0

<6.6 Ba-La-140 15.0

<4.0

<3.5

<6.6

<2.3 lab Code Required LLDs PAMl-2849 PAMI-3.585 PAMI-4523 PAMI-5434 Date Collected 5/7/96 6/4/96 7/10/96 8/9/96 Date Received 5/9/96 6/6/96 7/11/96*

8/12/96 1-131 1.0

<0.5

<0.3

<0.2

<0.4 K-40 950+/-150 1290+/-150 1260+/- 110 1150+/-80 Cs-134 15.0

<3.0

<5.3

<3.3

<3.S Cs-137 18.0

<2.7

<5.4

<4.6

<3.2 Ba-La-140 15.0

<3.8

<3.1

<4.0

<4.4.

lab Code Required LLDs PAMl-6188 PAMI-mJ4 PAMl-8118 PAMl-8688 Date Collected 9/10/96 10/8/96 11/6/96 12/3/96 Date Received 9/11/96

.10/11/96 11/11/96 12/5/96 1-131 1.0

<0.5

<0.4

<0.4

<0.3 K-40 1070+/-160 1150+/-150 1060+/- 100 990+/- 120 Cs-134 15.0

<6.9

<6.1.

<4.4

<2.5 Cs-137 18.0

<8.1

<<5.6

<3.2

<6.3 Ba-La-140 15.0

<5.2

<4.9

<2.3

<5.0 10-3

PALISADES Table 10.

Milk, analyses for iodine-131 and gamma-emitting isotopes.

Collection:

Monthly Units:

pCi/L Location:

WS - William Shine Farm lab Code Required LLDs PAMl-162 PAMI-635 PAMl-1156 PAMI-2049 Date Collected 1/9/96 2/7/96 3/6/96 4/11/96 Date Received 1/12/96 2/9/96 3/8/96 4/12/96 1-131 1.0

<0.4

<0.3

<0.5

<0.3 K-40 1430+/- 130 1450+/- 140 1350+/- 150 1490+/- 160 Cs-134 15.0

<5.5

<5.6

<1.9

<1.2 Cs-137 18.0

<5.1

<5.5

<6.0

<5.3 Ba-La-140 15.0

<2.8

<7.6

<9.0

<2.1 Lab Code Required LLDs PAMI-2847 PAMI-3586 PAMI-4522 PAMI-5433 Date Collected 5/7/96 6/4/96 7/10/96 8/9/96 Date Received

. 5/9/96 6/6/96 7/11/96 8/12/96 1-131 1.0

<0.3

<0.3

<0.3,

<0.4 K-40 1610+/- 130 1480+/- 170 1480+/- 170 1600+/- 150 Cs-134 15.0

<5.6

<10.0

<8.5

<6.1 Cs-137 18.0

<5.0

<4.1

<3.3

<5.0 Ba-La-140 15.0

<4.7

<6.3

<1.6

<7.1 LabCode Required LLDs PAMI-6190 PA¥1-6998 PAMI-8116 PAMI-8687.

Date Collected 9/10/96 10/8/96 11/6/96 12/3/96 Date Received 9/11/96 10/9/96 11/11/96 12/5/96 1-131 1.0

<0.3

<0.4

<0.4

<0.3 K.40 1420+/- 130 1460+/- 180 1380+/- 170 1370+/- 160 Cs-134 15.0

<4.0

<4.4

<6.1

<4.0 Cs-137 18.0

<5.4

<6.1

<5.1

<5.0 Ba-La-140 15.0

<4.9

<3.8

<4.2

<8.7 10-4

PALISAQES Table 11.

Food Crops, analyses for gross beta and gamma~mitting isotopes.

Collection:

Semiannually at the time of harvest Units:

pCl/g wet.

Location Paul Rood Fann ubCode Required LLDs PAVE-5484 PAVE-7037 PAVE-7038 Date Collected 8/11/96 10/7/96 10/7/96 Date Received 8/13/96 10/10/96 10/10/96 Sample Type Blueberries Pears-Apples Gross Beta 1.00 0.68+/-0.02 1.02+/-0.m 0.76+/-0.02 Mn-54 0.080

<0.009

<0.005

<0.019 Fe-59 0.10

<0.011

<0.012

<0.034 Co-58 0.080

<0.007

<0.008

<0.017 Co-60 0.050

<0.006

<0.012

<0.021 Zn~

0.10

<0.014

<0.017-

<0.022 Zr-Nb-95 0.10

<0.008

<0.005

<0.021 1-131 0.060

<0.010

<0.011

<0.047 Cs-134 0.080

<0.009

<0.011

<0.014 Cs-137 0.080

<0.008

<0.007

<0.014 Ba-La-140 0.10

<0.005

<0.007.

<0.012 Location J.SamoFarm ubCode Required LLDs PAVE-4029 PAVE-5485 PAVE-5486 PAVE-5487 Date Collected 6/24/96 8/11/96 8/11/96 8/11/96 Date Received 6/'J!J/96 8/13/96 8/13/96 8/13/96 Sample Type Strawberries Peaches Plwm Apples Gross Beta 1.00 0.95+/-0.02 1.54+/-0.0&

1.46+/-0.03 2.01+/-0.04 Mn-54 0.080

<0.006

<0.<XM

< O.<Xl5

<0.013 Fe-59 0.10

<0.008

. <0.CY23

<0.015

<0.029 Co-58 0.080

<0.005

<0.009

<0.008

~0.016 Co-&>

0.050

<0.oo:3

<0.006

<0.009

<0.014 Zn~

0.10.

<0.011

<0.016

<0.007

<0.030 Zr-Nb-95 0.10

<0.008

<0.005

<0.005

<0.019 1-131 0.060

<0.014

<0.011

<0.007

<0.021 Cs-134 0.080

<0.006

<0.009

<0.009

<0.007 Cs-137 0.080

<0.007

<0.006

<0.010

<0.007 Ba-La-140 0.10

<0.007

. <0.<XM

<0.008

<0:011 11-1

PALISADES Table 11.

Food Crops, analyses for gross beta and ~tting isotopes.

Collection:

Semiannually at the time of harvest Units:

pO/g wet lab Code Required LLDs PAVE-7009 PAVE-7040 PAVE-7041 Date Collected 10/8/96 10/8/96 10/8/96 Date Received 10/10/96 10/10/96 10/10/96 Sample Type Concord Grapes Grapes Apples Gross Beta 1.00 0.99+/-0.0J.

5.01+/-0.26 1.60+/-0.ClS Mn-54 O.e&>

<0.013

<0.007

<0.018 Fe-59 0.10

<0.013

<0.0'l6

,<0.033 Co-58 O.e&>

<0.012

<0.015

<0.022 Co-60 0.050

<0.019

<0.015

<0.0'24 Zn-6.5 0.10

<0.018

<0.014

<0.017 Zr-Nb:.95 0.10

<0.<D

<0.014

< 0.0'21 1-131 0.060

<0.0'25

<0.0'l7

<0.050 Cs-134 0.080

<0.013

<0.011

<0.0'21 Cs-137 0.080

<0.<D

<0.011

<0.009 Ba-La-140 0.10

<0.009

<0.008

<0.019 11-2

PALISADES Table 12.

rash. analyses for gross beta, strontium 89, strontium 90 and gamma-emitting isotopes.

Collection:

Semiannually Units:

pCi/gwet Location Palisades Discharge lab Code Required LLDs PAF-5515, 6 PAF-5517 PAF-5518 PAF-5519 Date Collected 7/'JS/96 7/'JS/96 7/'JS/96 7/'JS/96 Date Received 8/14/96 8/14/96 8/14/96 8/14/96 Freshwater Sample Type Trout Gizzard Shad White Sucker

  • Drum Gross Beta 1.00 2.49+/-0.06 2.04+/-0.08 2.27+/-0.13 2.33+/-0.<JJ Mn-54 0.13

<0.011

<0.009

<0.008

<0.016 Fe-59 0.26

<0.022

<0.046

<0.015

<0.024 Co-58 0.26

<0.011

<0.012

<0.007

<0.021 QH,O 0.26

<0.005

<0.006

<0.006

<0.019 Zn-&5 0.26

<0.015

<0.018

<0.021

<0.022 Zr-Nb-95 0.10

<0.017

<0.016

<0.009

<0.019 Cs-134 0.13

<0.009

<0.014

<0.012

<0.009 Cs-137 0.15 O.n53 +/- 0.012

<0.017

<0.011 0.045 +/- 0.019 Ba-La-140 0.10

<O.ms

<0.007

<0.022

<0.008 lab Code Required LLDs PAF-9117 PAF-9118 Date Collected 11/6/96 11/6/96 Date Received 12/16/96 12/16/96 Sample Type Carp Brown Trout Gross Beta 1.00 2.41+/-0.05

'1.95+/-0.0'7 Mn-54 0.13

<0.<m

<0.012 Fe-59 0.26

<0.015

<0.021 Co-58 0.26

<0.010

<0.019 QH,O 0.26

<0.<m

<0.019 Zn-&5 0.26

<0.021

<0.028 Zr-Nb-95 0.10

<0.0'l3

<0.018 Cs-134 0.13

<0.010

<0.015 Cs-137.

0.15

<0.011 0.0'26 +/- 0.015 Ba-La-140 0.10

<0.004

<0.046 12-1

PALISADES Table 12.

Fish, analyses for gross beta, strontium 89, strontium 90 and gamma-emitting isotopes.

Collection:

Semiannually Units:

pCi/gwet Location Ludington Pumped StoraS! Plant ~Control) lab Code Required LLDs PAF-4452, 3 PAF-4454 PAF-7754 PAF-7819 Date Collected 6/12/96 6/12/96 10/8/96 10/8/96 Date Received 7/8/96 7/8196 11/1/96 11/5/96 Sample Type White Sucker Brown Trout Lake Trout Sucker Gross Beta 1.00 2.;13+/-0.08 1.67+/-0.06 2.16+/-0.07 2.11+/-0.08 Mn-54 0.13

<0.~

<0.~

<0.007

<0.010 Fe-59 0.26

<0.013

<0.m.3

<0.027

<0.0U Co-58 0.13

<0.004

<0.006

<0.012

<0.007

~

0.13

<0.003

<0.007

<0.006*

<0.009 Zn-65 0.26

<0.006

<0.015

<0.020

<0.014 Zr-Nb-95 0.10

<0.011

<0.013

<0.020

<0.0'21 Cs-134 0.13

<0.~

<0.007

<0.010

<0.~

Cs-137 0.15 0.013 +/- 0.004 0.0'25 +/- 0.010 0.045 +/- 0.011 0.015 +/- 0.009 Ba-La-140 0.10

<0.()1)3

<o.zt

<0.057

<0.097 lab Code Required LLDs Date Collected Date Received Sample Type Gross Beta 1.00 Mn-54 0.13 Pe-59 0.26 Co-58 0.13

~

0.13 Zn-65 0.26 Zr-Nb-95 0.10 Cs-134 0.13 Cs-137 0.15 Ba-La-140 0.10

  • Required LLD not met due to delay in analysis
  • 12-2

PALISADES Table 13.

Algae, analyses for gross beta and gamma-emitting isotopes.

Collection:

Semiannually Units:

pO/g wet Location Discharge lab Code Required LLDs PASL-5733 PASL-9119 Date Collected 8/2/96 10/4/96 Date Received 8/'Z3/96 12/16/96 Gross Beta 1.00 1.25+/-0.09 2.48+/-0.26 Mn-54 0.13

<0.012

<0.025 Fe-59 0.26

<0.053

<0.071 C0-58 0.13

<0.018

<0.031

~

0.13

<0.014

<0.016 Zn~

0.26

<0.0'26

<0.080 Zr-Nb-95 0.10

<0.023

<0.058 Cs-134 0.13

<0.015

<0.019 Cs-137 0.15

<0.016

<0.0'24 Ba-La-140 0.10

<0.100'

< 1.360 Location Ludington (Control) lab Code Required LLDs Date Collected Date Received Gross Beta 1.00 Mn-54 0.13 Fe-59 0.26

~58 0.13 Co-@

0.13 Zn~

0.26 Zr-Nb-95 0.10 Cs-134 0.13 Cs-137 0.15 Ba-La-140 0.10 13-1

PALISADES Table 14.

Bottom Sediments, analyses for gross beta and gamma-emitting isotopes.

Collection:

Semiannually Units: *.

pO/g dry Location Palisades Discharge lab Code Required LLDs PABS-3037 PABS-7135 Date Collected 5/2/96 10/4/96 Date Received 5/14/96 10/11/96 Gross Beta 1.00 6.27+/- 1.82 2.52+/- 1.24 Mn-54 0.080

<0.018

<0.015 Fe-59 0.10

<0.036

<0.034 Co-58 0.080

<0.019

<0.014 Co-(,()

0.050

<0.013

<0.006 Zn~

0.10

<0.<l%

< O.o.52 Zr-Nb-95 0.10

<0.0'20

<0.009 Cs-134 0.15

<0.0'21

<0.0'25 Cs-137 0.18

<0.016

<0.016 Ba-La-140 0.10

<0.0'29

<0.0'21 Location Ludingtm (Control) lab Code Required LLDs PAB5-4455 PABS-7818 Date Collected S/'1B/96 10/7/96 Date Received

. 7/8/96 11/5/96 Gross Beta 1.00 6.75+/- 1.3.5 10.32+/- 1.53 Mn-54

. 0.080

<0.0'24

<0.018 Fe-59 0.10

<0.055

<0.009 Co-58 0.080

<0.011

<0.(Q Co-60 0.050

<0.016

<0.010.

  • Zn~

0.10

<0.060

. <0.050 Zr-Nb-95 0.10

<0.040

<0.013 Cs-134 0.15

<0.019

<0.017

<0.017 0.0'26 +/- Q.013 Ba-La-140 0.10

<0.Clll

<0.067 14-1

PALISADES Table 14.

Bottom Sediments, analyses for gross beta and gamma~mitting isotopes.

Collection:

Semiannually Units:

pCi/g dry Location North Propertr (0.8 mi.)

Lab Code Required LLDs PABS-3036 PABS-7137 Date Collected 5/2/96 10/4/96 Date Received 5/14/96 10/11/96 Gross Beta 1.00 6.14+/- 1.87 5.02+/-2.18 Mn-54 O.c&>

<0.016

<0.020 Pe-59 0.10

<0.066

<0.025 Co-58 O.c&>

<0.021

<0.023 QHj()

0.050

<0.010

<0.013 Zn~

0.10

<0.C1T1

<0.069 Zr-Nb-95 0.10

<0.020

<0.013 Cs-134 0.18

<0.017

<0.028 Cs-137 0.18

<0.018

<0.016 Ba-La-140 0.10

<0.023

<0.024 Location South Haven (8.9 km north) lab Code Required LLDs PABS-3038 PASS-7138, 9

. Date Collected 5/2/96 10/4/96 Date Received 5/14/96 10/11/96 Gross Beta 1.00 7.15+/- 1.98 8.75+/- 1.70 Mn-54 O.c&>

<0.020

<0.017 Pe-59 0.10

<0.00

<0.052 Co-58 O.c&>

<0.0'll

<0.013 QHj()

0.050

<0.012

<0.010 Zn~

0.10

<0.06.5

<0.058 Zr-Nb-95 0.10

<0.021

<0.009 Cs-134 0.15

<0.0'll

<0.026 Cs-137 0.18

<0.015

<0.015 Ba-La-140 0.10

<0.019

<0.019 14-2

PALISADES Table 14.

Bottom Sediments, analyses for gross beta and gamma~mitting isotopes.

Collection:

Semiannually Units:

pCi/g dry Location South PropertY (0.8 mi.)

Lab Code Required LLDs PABS-3035 PABS-7136 Date Collected 5/2/96 10/4/96 Date Received 5/14/96 10/11/96 Gross Beta 1.00 3.85+/- 1.12 557+/-2.21 Mn-54 0.030

<0.013

<0.0'29 Fe-59 0.10

<0.024

<0.024 Co-58 0.030

<0.012

<0.025 Co-liO 0.050

<0.007

<0.018 Zn-65 0.10

<0.0U

<0.076 Zr-Nb-95 0.10

<0.019

<0.033 Cs-134 0.15

<0.014

<0.007 Cs-137 0.18

<0.012

<0.024 Ba-La-140 0.10

<0;023

<0.0'75 14-3

PALISAQES Table 15.1. Liquid radwaste, analyses for gross alpha, tritium, strontium-89, strontium-9(),

plutonium-239 and gamma-emitting isotopes.

Collection:

Monthly Units:

uO/mL Location Palisades lab Code Required LLDs No*

No*

No*

Date Collected 1/31/96 2/29/96 3/31/96 Date Received Gross Alpha 1.0E-07 H-3 1.0E~

Sr-89 5.0 E.al Sr-90 5.0E.al Pu-239 5.0E.al Cr-51 5.0E-07 Mn-54

  • 5.0E-07 Fe-59 5.0E-07 Co-58 5.0 E-0'1 Co-(,(}

5.0E-07 Zn~

5.0E-07 Zr-95 5.0E-07 Nb-95 5.0E-07 Ag-110m 5.0 E-07 Sb-124

  • 5.0E-07 Cs-134 5.0E-07 Cs-137 5.0E-07 Ba-140 5.0E-07 La-140 5.0E-07 Ce-141 5.0E-07 Ce-144 5.0E-0'1 15.1-1

PALISADES Table 15.1. Uquid radwaste, analyses for gross alpha, tritium, strontium-89, strontium-90, plutonium-239 and gamma-emitting isotopes.

Collection:

Monthly Units:

uCl/mL lab Code Required LLDs PARW-3166 No*

No*

Date Collected 4/9/96 5/31/96 6/'!JJ/96 Date Received 5/Zl./96 Gross Alpha 1.0 E-07 1.9E-8 +/- 2.7E-9 H-3 1.0 E-05 1.9E-1 +/- 2.9E-4 Sr-89 5.0E.al

<4.SE-9 Sr-90 5.0E.al 2.3E-8 +/- 2.9E-9 Pu-239 5.0.E.al 1.2E-9 +/-3.8E-10 Cr-51 5.0E-07

<8.9E-8 Mn-54 5.0 E-07 2.4E-8 +/- 6.8E-9 Fe-59 5.0 E-07

<3.2E-8 Co-58 5.0 E-07 6.0E-7 +/- 1.8E-8

~

5.0 E-07 1.3E-6 +/- 1.4E-8 Zn-6.5 5.0 E-07

<2.9E-8 Zr-95 5.0E-07

<3.6E-8 Nb-95 5.0 E-07

<2.lE-8 Ag-.llOm 5.0 E-07 7.4E-8 +/- 1.2E-8 Sb-124 5.0 E-07 O.OE-1 +/- 2.4E-8 Cs-134 5.0E-07 1.lE-7 +/-6.2E-9 Cs-137 5.0 E-07 4.9E-7 +/- 1.lE-8 Ba-140 5.0E-07

<2.9E-7 La-140 5.0 E-07

<4.4E-8 Ce-14i 5.0 E-07

<2.2E-8 Ce-144 5.0E-07

<7.3E-8 15.1-2

PALISADES Table 15.1. Liquid radwaste, analyses for gross alpha, tritium, strontium-89, strontium-90, plutonium-239 and gamma-emitting isotopes.

Collection:

Monthly Units:

uCi/mL Lab Code Required LLDs PARW-5717 PARW-5718 No*

Date Collected 7/31/96 8/5/96 9/'!JJ/96 Date Received 8/'Zl./96 8/'12/96 Gross Alpha 1.0E-07

<1.9E-9 2.6E-9 +/- 13E-9 H-3 1.0 E"'°'

3.9E-1 +/- 13E-4

.23E-1 +/-9.7E-5 Sr-89 5.0E~

<2.7E-9

<2.7E-9 Sr-90 5.0E~

< 1.4E-9 33E-8 +/- 2.SE-9 Pu-239 5.0E~

<5.4E-11

< 1.2E-10 Cr-51 5.0E-07

<4.SE-8

< 1.4E-7 Mn-54 5.0E-07 5.9E-9 +/- 3.2E-9 23E-8 +/- 6.4E-9 Fe-59 5.0E-07

<13E-8

<6.lE-9

  • Co-58 5.0E-07

<8.2E-9 1.6E-7 +/- 9.8E-9 Co-60 5.0E-07 3.4E-8 +/- 4.8E-9 4.0E-7 +/- 7.9E-9 Zn~

5.0E-07

< 1.SE-8

. <1.8E-8 Zr-95 5.0E-07

< 1.6E-8

<13E-8 Nb-95 5.0E-07

<7.9E-9

<8.9E-9 Ag-110m 5.0E-07

<6.7E-9 1.9E-8. +/- 8.SE-9

'i Sb-124 5.0E-07 O.OE-1 +/- 9.4E-9 O.OE-1 +/- 33E-8 Cs-134 5.0E-07

<53E-9 4.8E-7 +/- 8.lE-9 Cs-137 5.0E-07 2.2E-8 +/- 4.4E-9 2.0E-6 +/- 1.9E-8 Ba-140 5.0E-07

<7.2E-8

< 1.6E-7

. La-140 5.0E-07

<1.0E-8

<1.7E-8 Ce-141 5.0E-07

<1.SE-8

<1.9E-8 Ce-144 5.0E-07

<6.7E-8

<83£-8 15.1-3

eALISACES Table 15.1. Liquid radwaste, analyses for gross alpha, tritium. strontium-89, strontium-90, plutoniwn-239 and gamma~mitting isotopes.

Collection:

Monthly Units:

uO/mL lab Code Required LLDs ND*

PARW-8832 ND*

Date Collected 10/31/96 11/30/96 U/31/96 Date Received U/10/96 Gross Alpha 1.0 E-0'1 2.3E-9 +/- 1.3E-9 H-3

  • 1.0 E-05 1.7E-3 +/- 8.SE-6 Sr-89 5.0E-08

<2.lE-9 Sr-90 5.0E-08 1.3E-8 +/- 1.6E-9 Pu-239 5.0E-08*

<9.4E-11 Cr-51 5.0E-0'1

<2.2E-7 Mn-54 5.0 E-0'1 1.3E-8 +/- 6.lE-9 Fe-59 5.0 E-0'1

<1.9E-8 Co-58 5.0 E-0'1 3.9E-7 +/- 1.6E-8 Co-(,()

5.0 E-0'1

. 1.7E-7 +/- 7.4E-9 l.n-65 5.0 E-0'1

< 1.8E-8 Zr-95 5.0 E-0'1

<1.8E-8 Nb-95 5.0 E-0'1

<9.SE-9 Ag-llOm S.O E-0'1

<l.lE-8 Sb-124 5.0E-0'1 O.OE-1 +/- 4.0E-8 Cs-134 5.0 E-0'1 4.2E-7 +/- 9.9E-9 Cs-137 5.0E-0'1 1.9E-6 +/- 2.4E-8 Ba-140 5.0E-0'1

<2.7E-7 La-140 5.0 E-0'1

<2.4E-8 Ce-141 5.0 E-0'1

. <2.8E-8 Ce-144 5.0E-0'1

<l.lE-7

  • ND = No data; sample not received.

15.1-4

PALISADES Table 15.2. Stack filters, analyses for gross alpha. plutonium 239, strontium 89 and strontium 90.

Collection:

Continuous, monthly exchange Units:

pCi/filter Location Palisades LabCod.e Required LLDs PASP-848 PASP-1359 PASP..J164 Date Collected 1/~/96 2/'17/96 3/'lD/96 Date Received 2/'ZJ./96 3/18/96 5/D./96 Gross Alpha 10 o.s+/-o.4*

<OJ9

<0.6.

Sr-89 10

<5.2

<4.7

<7.0 Sr-90 10

<2.2

<2.1 2.3+/- 1.3 Pu-239 10

<0.1

<0.3

<0.6.

lab Code Required LLDs PASP..J165 PASP-3768 PASP-4581 Date Collected 4/30/96 5/'1B/96 6/25/96 Date Received 5/'ZJ./96 6/14/96 7/12/96 Gross Alpha 10

<OG

<ld

<OS Sr-89 10

<4.9

<6.6

<4.7.

Sr-90 10

<2.4

<3.7

<2.1 Pu-239 10

<1.0

<0.0

.<0.2 LabCode Required LLDs PASP-5719 PASP-6241 PASP-7133 Date Collected 7/~/96 8(Z1/96 9/24/96 Date Received 8/'ll/96 9/13/96 10/11/96 Gross Alpha 10 1.2+/-07

<ld

<o.7 Sr-89 10

<3:7

<2.8

<4.1 Sr-90 10 3.1+/- 1.1

<1.2

<2.8 Pu-239 10

<0.3

<0.2

<0.3 LabCode Required LLDs PASP-8136 PASP-8833 PASP-9634 Date Collected 10/'J!J/96 11/'17/96 12/31/96 Date Received 11/12/96 12/10/96

. 1/10/97 Gross Alpha 10

<0.5

<0.7 0.7+/-0.4 Sr-89

. 10

<5.0

<3.7 7.0+/-2.8 Sr-90 10

<2.4

<2.0

<2.5 Pu-239-10

<0.3

<0.3

<0.3

  • Corrected data.

b ND = No data; sample not received.

15.2-1

PALISAQES Table 15.4. Special Samples - Reactor Water, analyses for strontium-89 and strontium-90.

Collection:

Units:

uO/mL Location lab Code

  • Required LLDs Date Collected Date Received Sr-89 Sr-90 5.0E.al 5.0 E.al Palisades PARW-8137 10/17/96 11/12/96

<8~4E-10

<5.9E-10 15.4-1

PALISADES Table 15.5. Special Samples - Steam Generator Slowdown, analyses for gross alpha, strontium-89 and strontium-90.

Collection:

As required Units:

uCi/mL Location Lab Code Date Collected Date Received Gross Alpha Sr-89 Sr-90 Palisades; A SIG Required LLDs PARW-1360 1/18/96 3/18/96 1.0 E-07

< 2.7E-9 5.0 E-08

< 3.2E-9 5.0 E-08

. 9.9E-10+/- 6.lE-10 15.5-1

ENCLOSURE E CONSUMERS ENERGY COMPANY

. PALISADES PLANT DOCKET 50-255 PALISADES NUCLEAR PLANT 1996 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT

. EPA INTERLABORA TORY COMPARISON PROGRAM RES UL TS 37 Pages

INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE: Teledyne's Midwest Laboratory participates-in intercomparison studies ad.ministered by U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. The results are reported in Appendix A; Also reported are results of International lntercomparison and Teledyne testing of TLD's, as well as, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program. Appendix A is updated four times a year; the complete Append.ix is included in March, June, September and December monthly progress reports only. Please refer to March, June, September and December progress reports for infonnatim.

January, 1996 through December, 1996

Appencij1 A lnterlaboratocy Comparison Program Results Teledyne's Midwest Laboratory (formerly Hazleton Environmental Sciences) has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples (e.g.,

milk or water) containing concentrations of radionuclides know to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on the laboratory's analytical procedures and to alert it to any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instrwnents or procedures used.

The results in table A-1 were obtained through participation in the environmental sample crosscheck program for milk, water and air filters during the past twelve months. Data for previous years is available upon request.

This program is conducted by the U.S. Enviror;unental Protection Agency lntercomparison and Calibration Section, Quality Ass\\irance Branch, Environmental Monitoring and Support Laboratory, Las V eg8;9, Nevada.

The results in Table A-2 were obtained for Thermoluminescent Dosimeters (Tl.Os), since 1976 via various International Intercomparisons of Environmental Dosimeters under the sponsorships listed in Table A-2. Also Teledyne testing results are listed.

Table A-3 lists results of the analyses on in-house "'spiked" samples for the past twelve months.

All samples are prepared using NIST tracable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "'blank~ samples for the pas't twelve months.

Data for previous years available upon request.

Table A-5 list results of the in-house.,duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors. Data for previous years available upon request.

The results in Table A-6 were obtained through participation in the "mixed analyte performance evaluation program.

The results in Table A-7 were obtained through participation in the Environmental Measurement Laboratory Quality.As.9essment Program.

Attachment A lists acceptance criteria for "'spiked" samples.

Out-of-limit results are explained directly below the result.

Al

Table A-1.

US. Environmental Protection Agency" s crosscheck program, comparison of EPA and Teledyne's Midwest Laboratory results for various sample media".

Concentration in ~/Lb Lab Sample Date Teledyne Results EPA Resultd Control Code T~e Collected Anal~sis

+/-2 Sigma*

ts, N=l Limits STW-752 WATER Jan, 1996 Gr. Alpha 19.5+/- 1.5 12.1+/-5.0 3.4 - 20.8 STW-752 WATER Jan, 1996 Gr. Beta 7.9+/-0.1 1.0+/-5.0 0.0- 15.7 STW-753 WATER Feb, 1996 1-131 70.1+/- 1.5 67.0+/- 7.0 54.9 - 79.1 STW-761 WATER Mar, 1996 H-3 22,776.7 +/- 185.0 22,002;0+/- 2,200.0 18,185.1 - 25,818.9 Results where indavertently not reported due to administrative error in laboratory.

STW-762 WATER Apr, 1996 Gr. Alpha 63.8+/-2.4 74.8+/- 18.7 42.4 - 107.2 STW-762 WATER Apr, 1996 Ra-226 2.9+/-0.1 3.0+/-0.5 2.1-3.9 STW-762 WATER Apr, 1996 Ra-228 4.6+/-0.2 5.0+/- 1.3 2.7 - 7.3 STW-762 WATER Apr, 1996 Uranium 51.9+/-0.5 58.4+/-5.8 48.3-68.5 STW-763 WATER Apr, 1996 QH,()

32.7+/-0.6 31.0+/-5.0 22.3 - 39.7 STW-763 WATER Apr, 1996 Cs-134 43.0+/- 1.0 46.0+/-5.0 37.3 - 54.1 STW-763 WATER Apr, 1996. Cs-137 52.3+/- 2.1 50.0+/-5.0 41.3 - 58.7 STW-763 WATER Apr, 1996 Gr. Beta 154.9+/-6.8 166.9+/- 25.0 123.5 - 210.3 STW-763 WATER Apr, 1996 Sr-89 42.0+/-3.6 43.0+/-5.0 34.3 ~ 51.7 STW-76.3 WATER Apr, 1996 Sr-90 15.3+/-2.9 16.0+/-5.0 7.3 - 24.7 STW-764 WATER Jun, 1996 Ba-133

745.0+/- 19.5 145.0+/-15.0 614.9 - 875.1 STW-764 WATER Jun, 1996 QH,()

97.0+/-3.6 99.0+/-5.0 90.3 - 107.7 STW-764 WATER Jun, 1996 Cs-134 72.3+/- 1.2 79.0+/-5.0 70.3-87.7 STW-764 WATER Jun, 1996 Cs-137 201.3+/-2.3 197.0+/- 10.0 179.7 - 214.3 STW-764 WATER Jun, 1996 Zn~

298.0+/-6.2 300.0+/-30.0 248.0 - 352.0 STW-765 WATER Jun, 1996 Ra-226 4.8+/-0.1 4.9+/-0.7 3.7 - 6.1 STW-765 WATER Jun, 1996 Ra-228 8.7+/-0.5 9.0+/-2.3 5.0- 13.0 STW-765 WATER Jun, 1996 Uranium 20.4+/-0.8

-20.2+/-3.0 15.0- 25.4 STW-767 WATER Jul, 1996 Sr-89 24.0+/-2.0 25.0+/-5.0 16.3 - 33.7 STW-161 WATER Jul, 1996 Sr-90 11.3+/- 1.2 12.0+/-5.0 3.3-20.7_

STW-768 WATER Jul, 1996 Gr. Alpha 20.1+/-2.0 24.4+/-6.1 13.8-35.0 STW-768 WATER Jul, 1996 Gr. Beta 40.4+/-3.2 44.8+/-5.0 36.1-53.5 STW-774 WATER Sep, 1996 Ra-226 13.6+/-0.4 14.0+/-2.1 10.4 - 11.6 STW-774 WATER Sep, 1996 Ra-228 5.4+/-0.4 4.7+/-1.2 2.6-6.8 STW-774 WATER Sep, 1996 Uranium 10.0+/-0.2 10.1+/-3.0 4.9 - 15.3 STW-775 WATER Oct, 1996 1-131 26.7+/-2.3 27.0+/-6.0 16.6-37.4 STW~778 WATER Oct, 1996 Gr. Alpha 10.2+/-2.1 10.3+/-5.0 1.6-19.0 -

STW-778 WATER Oct, 1996 Gr. Beta 32.0+/- 1.6 34.6+/-5.0 25.9 - 43.3 Al-1

Table A-1.

US. Environl18\\tal Protection Agency's crosschec.k program. comparison of EPA and Teledyne's Midwest Laboratory re5ults for various sample media'.

Lab Code Sample Type Date Teledyne Results Collected Analysis

+/-2 Sigmac Concentration in pCi/Lb EPA Result4 ls, N=l Control limits

  • Results obtained by Teledyne Brown F.ngineering Environmental Services MidweSt Laboratory as a participant in the environmental sample crosscheck program operated by the lnterromparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, U.S.

Environmental Protection Agency (EPA), las Vegas, Neveda.

b All results are in pCi/l, except for elemental potassium (K) data in milk, which are in mg/L; air filter samples, which are in pCi/Filter.

c Unless otherwise indicated, the TBEESML results are given as the mean+/- 2 standard deviations for three determinations.

4 USEPA results are presented as the known values and expected laboratory precision {ls, 1 determination)

  • and control limits as defined by the EPA.

Al-2

12-31-96 ATIACHMENTA ACCEPTANCE CRITERIA FOR "SPII<ED SAMPLEs LA BORA TORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANAL YSE'.S-Analysis Gamma Emitters Strontium~9b Strontium-9d' Potassium Gross alpha Gross beta Tritium Radium-226,-228 Plutonium lodine-131, Iodine-1~

Uranium-238, Nickel~b Technetium.I#

_Iron-~

Level 5 to 100 pCi/liter or kg

>100 pCi/liter or kg 5 to 50 pCi/liter or kg

>50 pCi/liter or kg 2 to 30 pCi/liter or kg

>30 pCi/liter or kg

>-0.1 g/liter or kg sio pCi/liter

>20 *pCi/liter slOO pCi/liter

>100 pCi/liter s4,000 pCi/liter

>4,000 pCi/liter

<0.1 pCi/liter

  • 0.1 pCi(liter, gram, or sample s,55 pCi/llter

>5.5 pCi/Uter

~

pCi/Uter

>35 pCi/liter 50 to 100 pCi/liter

- > 100 pCi/liter One Standard Deviation for single determinations 5.0 pCi/liter 5% of known value 5.0 pCi/liter 10% of known value 5.0 pCi/liter 10% of known value 5% of known value 5.0 pCi/llter 25% of known value 5.0 pCi/liter 5% of known value ls = (pCi/liter) =

169.&5 x (known)o.om 10% of known value 15% of known value 10% of known value 6.0 pCi/liter 10% of known value 6.0 pCi/liter 15% of known value 10 pCi/liter 10% of known value 20% of known value

  • From EPA publication. "Environmental Radioactivity laboratory lntercomparison Studies Program. Fiscal Year, 1981-1982, EPA~/4-81-004.

b Teledyne limit.

A2

Table A-2. Crosscheck program results; Thermolwninescent Dosimeters. (Tl.Os).

Lab Code TI.OType Date 2nd International Interrnmpamon 115-2 115-2 CaF2: Mn Bulb Apr, 1976 CaFz: Mn Bulb Apr, 1976 Teledyne Results Measurement

+/- 2 Sigma Field Lab 17.0+/- 1.9 20.8+/-4.1 mR Krown Average +/- 2 Sigma Value+/- 2 Sigma (All Participants) 17.1 21.3 16.4+/-7.7 18.8+/-7.6 Second International lntercomparison of F.nvironmental Dosi.meters cooducted in April of 1976 by the Health and Safety Laboratory (HASL), New York, new York, and the School of Public Health of the University of Texas, Houston, Texas.

3rd Intematiooa1 lntercomparison 115-3 CaF2: Mn Bulb Jun, 1'177 115-3 CaFz: Mn Bulb Jun, 1'177 Field Lab 30.7+/-3.2 89.6+/-6.4 34.9+/-4.8 31.5 +/- 3.0 91.7+/- 14.6 86.2+/-24.0' Third International lntercomparison of F.nvironmental Dosimeters conducted in the summer of 1977 by Oak Ridge National Laboratory and the School of Public Health of the University of Texas, Houston, Texas.

iih Iotematicoa1 In~z:ccm12atl:Km.

115-4 CaFz: Mn Bulb Jun, 1979 Field 14.1+/-1.1 14.1+/-1.4 16.0+/-9.0 115-4 CaFz: Mn Bulb Jun, 1979 Lab, High 40.4+/- 1.4 45.8+/-9.2 43.9+/- 13.2 115-4 CaFz: Mn Bulb Jun, 1979 tab, low 9.8+/- 1.3 12.2+/- 2.4 12.0+/- 7.4

. Fourth International lntercomparison of EnvirOIUJ'e'\\tal Dosimeters conducted in the summer of 1979 by the School of Public Health of the University of Texas, Hous~ Texas.

5th Iotematicoa1 Inta:ccmgaria 115-5A CaFz: Mn Bulb Oct, 1980 Field 31.4+/- 1.8 30.0+/-6.0 30.2+/- 14.6 115-5A CaFi: Mn Bulb Oct, 1980 Lab,End 96.6+/-5.8 88.4+/-8.8 90.7+/-31.2 115-5A CaFz: Mn Bulb Oct, 1980 Lab, Start 77.4+/-5.8 75.2+/-7.6 75.8+/-40.4 Fifth International lntercomparison of Environmental Dosimeters conducted in the fall of 1980 at Idaho Falls, Idaho and sponsored by the School of Public Health of the University of Texas, Houston, Texas and the Environmental Measurements Laboratory, New York, New York, US. Department of Energy.

Sth Iotematicoa1 Intea:mnp.uison 115-58 UF-100 Chips Oct, 1980 Field 30.3 +/- 4.8 30.0 +/- 6.0 30.2 +/- 14.6 115-58 LiF-100 Chips Oct, 1980 Lab, End 85.4+/-11.7 88.4 +/- 8.8 90.7 +/- 31.2 115-58 LiF-100 Chips Oct, 1980 Lab, Start 81.1+/-7.4.

.75.2+/- 7.6 75.8 +/- 40.4 Fifth International lntera>mparison of Environmental Dosimeters cof'(fucted in the fall of 1980 at Idaho Falls, Idaho and sp0nsored by the School of Public Health of the University of Texas, Houston, Texas and the Environmental Measurements Laboratory, New York, New York, US. Department of Energy.

6th lntematiooa1 Interc;omparison.

115~

Teledyne did not participate in the Sixth International Intercomparison of Environmental [)osimeters.

Zth In~matiooal lnterccmparison 115-7 A UP-100 Chips Jun, 198' 115-7 A LiF-100 Chips Jun, 198'.

115-7 A UP-100 Chips Jun, 198' Field Lab,Co-liO Lab, Cs-137 A2-1 75.4+/-2.6 80.0+/-3.S 66.6+/- 2.S 75.8+/-6.0 79.9+/-4.0 75.0+/- 3.8 75.1+/-29.8 77.9+/-27.6 73.0+/-22.2

Table A-2. Crosscheck program results; Thermolwninescent Dosimeters. (TLOs).

Lab Code 11.DType Date Teledyne Results Measurement

+/- 2 Sigma mR Known Average +/- 2 Sigma Value+/- 2 Sigma (All Participants)

Seventh International _lntercomparison of Environmental Dosimeters conducted in the spring and. summer of 1984 at Las Vegas, Nevada, and sponsored by the U.S. Department of Energy, The Nuclear Regulatory Commission, and the U.S. Environmental Protection Agency.

7th lntemattgnaJ lntgr,gmpariggn 115-7B UF-100 Chips Jun, 1984 field 71.S+/- 2.6 75.8+/- 6.0 75.1+/-29.8 115-7B Uf-100 Chips Jun,198' Lab,Co-@

84.8+/-6.4 79.9+/-4.0 77.9+/-27.6 115-7B UF-100 Chips Jun, 198' Lab, Cs-137 78.8+/-1.6 75.0+/- 3.8

  • 73.0 +/- 22.2
  • Seventh International Intercompariscn of Environmental Dosimeters conducted in the spring and summer of 1984 at Las Vegas, Nevada, and sponsored by the US. Department of Energy, The Nuclear Regulatory Commission, and the US. Environmental Protection Agency.

Zth IDwmatianal lnteJ:CQDll2llD:JOD 115-7C CaSO,: Dy Jun, 1984 field 76.8+/-2.7 75.8+/-6.0 75.1 +/-29.8 Cards 115-7C CaSO,: Dy Jun, 1984

.Lab, Co-(,()

82.5+/-3.7 79.9+/-4.0 77.9+/-27.6 Cards 115-7C CaSO,: Dy Jun, 1984 Lab,Cs-137 79.0+/-3.2 75.0+/-3.8 73.0+/-22.2 Cards Seventh International lntercompariscn of F.nvironmental Dosimeten conducted in the spring and summer-of 1984 at Las Vegas, Nevada, and sponsored by the US. Department of Energy, The Nu.clear Regulatory Commission, and the US. Environmental Protection Agency._

8th IDwmatimia.l Intm:o1D12adm 115-8A

. UF-100 Chips Jan, 1986 field, Site 1.

29.5+/- 1.4 29.7+/- 1.5 28.9+/- 12.4 115-8A UF-100Chips Jan,1986 Field,_Site2 11,3+/-0.8 10.4+/-0.5

.10.1-+/-9.1 115-8A UF-100 Chips Jan, 1986 Lab, Cs-137 13.7 +/- 0.9 17.2 +/- 0.9 16.2 +/- 6.8

. Eighth International lntercomparison of Environmental Dosimeters conducted in the fall and winter of 198.5-1986 at New York, New York, ard sponsored by the US. Department of Energy.

8th IntemationaJ Intea;gmparim 115-88 UF-100 Chips Jan.1986 Field, Site 1 32.3+/- 1.2 29.7+/- 1.5 28.9+/-12.4.

115-88 UF-lOOChips Jan,1986 Field,Site2 9.0+/-1.0 10.4+/-0.S 10.1+/-9.0 115-$8 UP-100 Chips Jan. 1986 Lab, Cs-137 15.8 +/- 0.9 17.2 +/- 0.9 16.2 +/- 6.8 Eighth International Intercompartson of Environmental Dosimeters conducted in the fall and winter of 198.5-1986 at New York,.New York, ard sponsored by the US. Department of Energy.

8th lommadanaJ ID~ompad!IOft 115-8C Caso,: Dy Jan, 1986 Field, Site 1 32.2+/-0.7 29.7+/- i.5 28.9+/- 12.4' Cards 115-8C CaSO,: Dy Jan, 1986 field, Site 2 10.6+/-0.6 10.4+/-0.5 10.1+/-9.0 Cards 115-8C Caso,: Dy Jan.1986 Lab,Cs-137 18.1+/-0.8 17.2+/- 0.9 16.2+/-6.8 Cards A2-2

Table A-2. Crosscheck.program results; Thermoluminescent Dosimeters. (11.Ds).

mR Lab Teledyne Results Known Average +/- 2 Sigma Code ll.D Type Date Measurement

+/- 2 Sigma Value+/- 2 Sigma (All Participants)

Eighth International Intercomparison of Environmental ~imeters conducted in the fall and winter of 1985-1986 at New York, New York, and sponsored by the US. Department of Energy.

9th lntgm,ationa.1 lntgrcomparisgo 115-9

'The Ninth International Intercomparisoo of Environmental Dosimeters was not available to Teledyne's Midwest Laboratory.

10th International Intercomparisgo '- - -.

115-lOA LiF-100 Otlps Aug, 1993 Field 25.7+/- 1.4 27.0+/- 1.6 26.4+/- 10.2 115-lOA LiF-lOOOtlps Aug,1993 Lab,l 22.7+/-1.6 25.9+/-1.3 25.0+/-9.4 115-lOA LiF-100 Otlps Aug, 1993 Lab, 2 62.7 +/- 2.6 72.7 +/- 1.9 69.8 +/- 20.3 The Tenth International Intercomparison of Environmental Dosimeters conducted in 1993 at Idaho State University and sponsored by the US. Department of Energy and the Idaho Sta~ University.

10th lotematigDiJ lnb:.1:ca1n12a.tison 115-108 Caso,: Dy Aug,1993 Field 26.0+/-2.3 27.0+/- 1.6 26.4+/- 10.2 Cards 115-108 Caso,: Dy

.Aug, 1993 Lab, 1 24.1+/- 1.7 25.9+/- 1.3 25.0+/- 9.4 Cards 115-108

. Caso,: Dy Aug,1993 Lab,2 69.2+/-3.0

  • 72.7+/- 1.9 69.8+/-20.3 Cards

. The Tenth International Intercomparison of F.nvironmental Dosimeters conducted in 1993 at Idaho Stat University and sponsored by the US. Department of Energy and the Idaho Stat University.

Teledyne Testini 89-1 LiF-100 Otlps Sep, 1989 Lab 21.0+/- 0.4 22.4 ND ND = No Data; Teledyne Testing was only performed by Teledyne.

Chips were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in September, 1989.

Teledyne Iesq 89-2 Teledyne Nov, 1989 CaSo,: Dy Cards Lab 20.9+/- 1.0 ND = No Data; Teledyne Testing was only performed by Teledyne.

20.3 Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in June, 1990.

Teledyne Testina

  • 90-1 Teledyne Jun, 191JO Lab 20.6+/- 1.4
  • 19.6
  • CaSo,: Dy Cards ND = No Data; Teledyne Testing was only performed by Teledyne.

Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in June, 1990.

A2-3 ND

. ND

Table A-2. Crosscheck program results; Thermoluminescent Dosimeters. (11.Ds).

mR*

Lab Code 11.DType Teledyne Results Known Average +/- 2 Sigma Measurement

+/- 2 Sigma Value+/- 2 Sigma {All Participants)

Date retedme Iestiog 90-2 Teledyne Jun, 1990 CaSo,: Dy Cards Lab 100.8+/-4.3 ND = No Data; Teledyne Testing was only performed by Teledyne.

100.0 Cards were irradiated by Dosimetry Asssociates, Inc., Northville, MI, in October, 1990.

Ieledme Iatin&

91-1 Teledyne Oct, 1990 Lab, 1 33.4+/-2.0 32.0 CaSo,: Dy Cards.

91-1 Teledyne.

Oct, 1990 Lab,2 55.2+/-4.7 58.8 CaSo,: Dy Cards 91-1 Teledyne Oct, 1990 Lab,3 87.8+/-6.2 85.S CaSo,: Dy Cards ND = No Data; Teledyne Testing was only performed by Teledyne.

. Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in October, 1991.

Ieledme Iatma 92-1 UF-100 O\\lps Feb, 199'2 Lab, 1 11.1+/-0.2 10.7 92-1 UF-100 OUps Feb, 199'2 Lab, 2 25.6+/-0.S 25.4 92-1 UF-100 OUps Feb, 199'2 Lab,3 46.4+/-0.S 46.3.

ND = No Data; Teledyne Testing was only performed by Teledyne.

OUps were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in February, 1992.

Id@dyne Iatiol 92-2 Teledyne. Apr, 199'2 Reader 1, 11 20.1+/-0.1 20.1 CaSo,: Dy Cards 92-2 Teledyne Apr, 199'2 Reader 1, #2 40.6+/-0.1 40.0 CaSo,: Dy Cards 92-2 Teledyne Apr, 199'2 Reader 1, #3 60.0+/- 1.3 60.3 CaSo,: Dy Cards 92-2 Teledyne Apr, 199'2 Reader 2, #1 20.3+/-0.3 20.1 CaSo,: Dy Cards 92-2 Teledyne Apr, 199'2 Reader 2, #2 39.2+/-0.3 40.0 CaSo,: l?Y Cards A2-4 ND ND ND ND ND ND ND ND ND ND ND ND

Table A-2. Crosscheck program results; Thermoluminescent Dosimeters. (Il.Ds).

Lab Code 92-2 TI.DType Date Measurement Teledyne Apr, 1992 Reader 2, #3 Ca.So,: Dy Cards Teledyne Results*

+/-2Sigma 60.7+/-0.4 ND = No Data; Teledyne Testing was only performed by Teledyne.

mR KnOwn Average +/- 2 Sigma Value+/- 2 Sigma (All Participants) 60.3 ND Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in April, 1992.

Ieled)1M! Testing 93-1 Teledyne Mar, 1993 Lab, 1 10.0+/- 1.0 10.2 ND UF-100 Chips 93-1 Teledyne Mar, 1993 Lab, 2 25.2 +/- 2.2 255 ND UF-100 Chips 93-1 Teledyne Mar, 1993 l..ab,3 42.7+/-5.7 45.9 ND UF-100 Chips ND = No Data; Teledyne Testing was only performed by Teledyne.

Chips were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in March, 1993. Due to a potential error of.1~12% when cards where irradiated, results of the testing on the cards will not be published. Data is available upon request.

Teledyne Testing 94-1 Teledyne Nov, 1994 Lab, 1 15.6+/-0.4 14.9 ND UF-100 Chips 94-1 Teledyne Nov, 1994 Lab, 2 30.2+/-0.4 29.8 ND UF-100 Chips 94-1 Teledyne Nov, 1994 Lab,3 59.2+/-0.3 59.7.

ND UF-100 Chips 94-1 Teledyne Nov, 1994 Reader 1, #1 14.9 +/- 0.1 14.9 ND Ca.so,: Dy Cards 94-1 Teledyne Nov, 1994 Reader 1, #2 30.8+/-0.1 29.8 ND Ca.So,: Dy

  • Cards 94-1 Teledyne Nov, 1994 Reader 1, #3 58.9+/-0.3 59.7 ND ea.so,: Dy Cards 94-1 Teledyne Nov, 1994 Reader 2, #1 15.4+/-0.2 14.9 ND Ca.so,: Dy Cards 94-1 Teledyne Nov, 1994 Reader 2, #2 31.4+/-0.2 29.8 ND Ca.So,: Dy Cards 94-1 Teledyne Nov, 1994 Reader 2, #3 60.1+/-0.3 59.7 ND Ca.So,: Dy Cards A2-5

Table A-2. Crosscheck program results; Thermolwninescent Dosimeters. (11.0s).

mR Lab Teledyne Results Code TI.D Tvt>e Date Measurement

+/- 2 Si2!N Known Average +/- 2 Sigma Value+/- 2 Sigma (All Participants)

ND = No Data; Teledyne Testing was only performed by Teledyne.

Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jeney, in November, 1994.

Ieh:Q}1>e Testini 95-1 LiF-100 Chips Mar, 1995 95-1 LiF-100 Chips Mar, 1995 95-1 LlF-100 Chips Mar, 1995 95-1 T~ledyne Mar, 1995 CaSo,: Dy Cards Lab, 1 Lab, 2 Lab,3 Reader 1, #1 95-1 Teledyne Mar, 1995 Reader 1, #2 CaSo,: Dy Cards 95-1 Teledyne Mar, 1995 Reader 1, #3 CaSo,: Dy Cards 16.1+/-0.2 31.7+/-0.1 59.1+/-0.6 16.4+/-0.1 34.9+/-0.1 64.4+/- 1.5 ND = No Data; Teledyne Testing was only performed by Teledyne

  • 15.7 32.3 60.8 15.7 NO 32.3 ND 60.8 ND Cards and OUps were irradiated by Teledyne Isotopes, Inc., WestwoOd, New Jeney, in March, 1995.

Id~Iatina 95-:2 Teledyne Mar, 1995 Reader 2, t1 16.4+/-0.2 15.7 ND CaSo,: Dy Cards 95-2 Teledyne Mar, 1995 Reader 2, #2 33.9+/-0.4 32.3 ND CaSo,: Dy Cards 95-2 Teledyne Mar, 1995 Reader 2, #3 60.5+/-0.3 60.8 ND CaSo,: Dy.

Cards ND = No Data; Teledyne Testing was only performed by Teledyne.

Cards and Otlps were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in March, 1995.

Id~Iaq 96-1 UP-100 Chips Mar, 1996 Lab, 1 15.9+/-0.3 15.4 96-1 UF-100 Chips Mar, 1996 Lab, 2 29.4+/-0.3 30.8 96-1 UF-100 Chips Mar, 1996 Lab,3 62.5+/- 1.3 62.5 96-1 Teledyne Mar, 1996 Reader 1, tl 14.4+/-0.1 15.4 ND CaSo,: Dy Cards 96-1 Teledyne Mar, 1996 Reader 1, #2 31.8+/-0.1 30.8 ND CaSo,: Dy Cards A2-6

Table A-2. Crosscheck program results; Thennoluminescent Dosimeters. (TI.Os).

Lab Code 96-1 11..DType Date MeasuremE!lt Teledyne Mar, 1996 Reader 1, #3 CaSo,: Dy Cards Teledyne Results

+/-2Sigma 64.7+/-0.4 ND = No Data; Teledyne Testing was only performed by Teledyne.

mR Known Average +/- 2 Sigma Value+/- 2 Sigma (All Participants) 62.5 ND Chips and Cards were irradiated by Teledyne Isotopes, Inc., Westwood, New Jersey, in March, 1996.

Teledyne Testing 96-2 Teledyne Mar, 1996 Reader 2, #1 CaSo,: Dy Cards 14.3+/-0.4 96-2 Teledyne Mar, 1996 Reader 2, #2 31.8+/-0.1 CaSo,: Dy Cards 96-2 Teledyne Mar, 1996 Reader 2, #3 68.6+/-0.1 CaSo,: Dy Cards ND = No Data; Teledyne Testing was only performed by Teledyne.

15.4 ND 30.8 ND 62.5 ND Chips and Cards were irradiated by Teledyne lsoto~, Inc., Westwood, New Jersey, in March, 1996.

A2-7

Table A-3. In-house "spike'" samples.

Concentration in pCi/L*

Lab Sample Date Teledyne Results Known Controlc Code Type Collected Anal~sis 2s,n=lb Activi!l Limits SPCH-607 OiARCOAL Feb, 1996 I-131(g) 0.3+/-0.0 0.3 0.2 - 0.4 CANISTER SPAP-609 AIR FILTER Feb,1996 Cs-137 2.2+/-0.0 1.9 1.1 - 2.7 SPAP-611 AIR FILTER Feb, 1996 Gr. Beta 6.8+/-0.0 8.0 0.0 - 18.0 SPW-621 WATER Feb, 1996 1-131 86.2+/-0.7 95.9 76.7 - 115.1 SPW-621 WATER Feb,1996 l-131(g) 96.2+/-4.7 95.9 57.5 - 105.. 9 SPW-622 WATER Feb, 1996 Gr. Alpha 96.4+/-6.6 82.8 41.4 - 124.2 SPW-622 WATER Feb, 1996 Gr. Beta 83.7+/-3.3

. 8.5.7 75.7 - 95.7 SPW-623 WATER Feb,1996 H-3 18228.7 +/- 391.3 17833.0 14266.4 - 21399.6 SPW-624 WATER Feb,1996 Co-60 231.0+/- 14.5 239.3 215.4 - 263.2 SPW-624 WATER Feb,1996 Cs-137 428.3+/- 24.1 428.3 385.5 - 471.1 SPMI-625 MILK Feb,1996 Cs-137

.63.1+/-3.2 53.5 43.5 - 63.5 SPMI-625 MILK Feb,1996 1-131 47.8+/-0.7 48.0.

36.0- 60.0

.SPMI-625 MILK Feb, 1996 1-131(g)

.48.0+/-2.9

. 48.0

,28.8-58.0 SPVE-1068 VEGETATION Feb, 1996 l-131(g)

. 0.8+/-0.0 0.8 0.5 - 1.1 SPMI-2217 MILK Apr, 1996 Cs-134 35.4+/-2.5 37.1 27.1-47.1 SPMI-2217.

MILK Apr,1996 Cs-137 117.2+/-5.4 106.6 95.9-117.3 SPW-2219 WATER Apr, 1996 Co-60 26.0+/-3.4 23.4 13.4-33.4 SPW-2219 WATER Apr, 1996 Cs-134 36.1+/-2.9 37.1 27.1-47.1 SPW-2219 WATER Apr, 1996 Cs-137 117.1+/-6.4

. 106.6 95.9-1113 SPW-2221 WATER Apr, 1996 Gr. Alpha 76.9+/-6.1 82.8 41.4 - 124.2.

SPW-2221 WATER Apr, 1996 Gr. Beta 1323+/-5.0 136.8 123.1 - 150.5 SPW-2223 WATER Apr, 1996 H-3 17538.9 +/- 354.1 17937.0 14349.6 - 21524.4 SPW-2283 WATER Apr, 1996 1-129 15;1+/-1.4 14.9 2.9-26.9 SPW-2285 WATER Apr, 1996 Pe-55 1.2+/-0.5 1.1

.0.0- 21.1 SPW-2287 WATER

. Apr, 1996 Tc-99 10.5+/-1.9 66.0 46.2 - 85.8 SPW-2289 WATER Apr, 1996 Am-241 71.4+/-0.4 82.8 49.7 - 115.9 SPW-2289 WATER Apr, 1996 Cm-244 31.9+/- 1.1 36.4 21.8 - 51.0 SPW-2291 WATER Apr, 1996 Th-230 41.6+/-1.9 4.5.0 27.0- 63.0 SPW-2292

  • wATEil Apr, 1996 U-238 46.2+/-2.0

-45.4 31.8.. 59.0 -

SPP-3420 FISH May, 1996 Cs-137 0.1+/-0.0 0.1 0.1- 0.1 SPW-3439 WATER May,1996 1-131 23.9+/-0.8 25.3 13.3 - 37.3 SPMI-3441 MILK May, 1996 1-131 23.5+/-0.S 25.3 13.3 - 37.3 SPMI-4054 MILK Jun, 191J6 Cs-134 28.1+/-2.6 313 21.3 - 41.3 SPMI-4054 MILK Jun, 191J6 Cs-137 47.0+/-3.7 42.5 32.5 - 52.5 SPMI-4054 MILK Jun, 191J6 l-131(g) 39.4+/-3.6 40.4 24.2-50.4 A3-1

Table A-3. In-house "spike" samples.

Concentration in pCi/L9 Lab Sample Date Teledyne Results Krown' Con trot*

Code Type Collected Anal~sis 2s, n=lb Activi!,l Limits SPMI-4054 MILK JWl. 1996 Cs-134 28.1 +/-2.6 3L3 21.3-41.3 SPMI-4054 MILK JWl. 1996 Cs-137 47.0+/- 3.7 42.S 32.S - 52.S SPMI-4054 MILK JWl. 1996 1-131 35.7+/-0.6 40.3 28.3 - 52.3 SPMl-4054 MILK JWl. 1996 1*131(g) 39.4+/-3.6 40.4 24.2 - 50.4 SPW-4246.

WATER JWl. 1996 Gr. Alpha 70.0+/-3.6 82.7 41.4 - 124.1 SPW-4246 WATER JWl. 1996 Gr. Beta 140..5+/-3.2 136.1 122.S - 149.7 '

SPAP-4750 AIR FILTER Jui 1996 Cs-137 2.2+/-0.0 1.9 1.1 - 2.7 SPW-4936 WATER Jui 1996 Co-60 1Q5j+/- 15.4 112.6 101.3 - 123.9 SPW-4936 WATER Jui 1996 Cs-134 127.1+/-10.9 135.2 121.7 - 148.7 SPW-4936 WATER Jui 1996 Cs-137 220.2+/-20.2 211.9 190.7 - 233.1 SPMI-4938 MILK Jui 1996 Cs-134 130.4+/- 11.4

. 135.2 121.7 - 148j SPMI-4938 MILK Jui 1996 Cs-137 229.2+/- 21.6 211.9 190.7 - 233.1 SPW-4942 WATER Jui 1996 Pe-55 2.0+/-0.5 1.8 0.0- 21.8

'SPP-4996 RSH Jui 1996 Cs-137 0.1+/-0.0 0.1 0.0- 0.1 SPAP-5669 AIR FILTER Jui 1996 Gr. Beta 1.0+/-0.0 1.8

' o:o-17.8 SPW-5700 WATER Aug, 1996 H-3 49589.0+/- 589.S 51Q58.0 40846.4 - 61269.6 SPMl-7384 MILJC Oct, 1996 1-131 35.0:t0.9 39.9 27.9 - 51.9 SPMl-7385 MILK Oct, 1996 Cs-134 19.5+/-2.4 21.4 11.4 - 31.4 SPMI-7385 MILJC Oct, 1996 Cs-137 26.0+/-3.9 24.1 14.1-34.1 SPMl-7385 MILJC Oct, 1996 l-13l(g) 117.3+/-6.4 114.1 68.S - 125.S SPMl-7444 MILJC Oct, 1996 1-131 64.S:t 14.4 79.9 6.3.9 - 95.8 SPW-7444 WATER Oct, 1996 1*131(g) 82.2+/- 16.2 79.9 47.9-89.9 SPMI-7445 MILJC Oct, 1996 1-131 235.5+/-2.8 199.7 159.8 - 239.6 SPW-7445 WATER Oct, 1996 1*13l(g)

' 190.9 +/- 14.1 199.7' 119.8-219j SPMl-7685 MILJC Oct, 1996 1-131 l<l3.6+/- 1.5 114.1 91.3-136.9 SPAP-2 AIR FILTER Oct, 1996 Gr. Beta 6.0+/-0.0 6.0 0.0- 16.0 SPS0-2478 son.

Oct, 1996 Cs-134 0.2+/-0.0 0.2 0.1- 0.2 SPS0-2478 son.

Oct, 1996 Cs-137 0.5+/-0.0 0.4 0.3- 0.6 SPCH-7473 OIARCOAL Oct, 1996

. CANISTER l-13l(g) 0.4+/-0.0.

0.4 0.2-o.s SPCH-7474 OIARCOAL Oct, 1996 l-131(g)'

0.5+/-0.0 0.5 0.3- 0.7 CANISTER SPAP-7476 AIR FILTER Oct, 1996 Cs-137 2.1+/-0.0 1.9 1.1-2.7 SPW-8734 WATER Nov, 1996 Co-60 42.4+/-7.2 4.3.0 33.0- 53.0 SPW-8734 WATER Nov, 1996 Cs-134 29.0+/-6.6 30.1 20.1-40.1 SPW-8734 WATER Nov, 1996 Cs-137 35.1+/-9.5 31.S 21.S - 41.S SPW-8740 WATER Nov, 1996 H-3 25383.S +/- 433.5 25075.0 20060.0 - 30090.0 A3-2

Table A-3. In-house "spike" samples.

Lab Code Sample Trpe Date Collected Analysis Concentration in pCi/L' Teledyne Results Known 2s,n=lb Activity

  • All results are in pCi/L, except for elemental potassium (K) in milk. which are in mg/L.; air filter samples, which are in pCi/Filter; and food products, which are in mg/kg.

b All samples are the results of single determinations.

c Control limits are based on Attachment A, page A2 of this report.

NOTE: For fish, Jello is used for the spike matrix. For vegetation, Sawdust is used for the spike matrix.

A3-3

Table A-4.

In-house "blank'" samples.

Concentration pCi/L *.

Teledyne Results Acceptance Lab Sample Sample

~4.66 Sigma~

Criteria Code Type Date Analysis LLD ActivityG (4.66 Sigma)

SPW-7 WATER Jan 1996 Ra-226

<0.02 0.02 +/-0.13

< 1.0 SPW-2 WATER Feb 1996 Ra-226

<0.02 0.01 +/-0.02

< 1.0 SPCH-608 CHARCOAL Feb 1996 1-131(g)

<2.7

-0.10+/-1.63

<9.6 CANISTER SPAP~lO AIR FILTER Feb 1996 Co-liO

<4.1 3.46 +/-339

<10.0 SPAP~lO AIR FILTER Feb 1996 Cs-134

<3.6

-0.25 +/-2.94

< 10.0 SPAP~lO AIR FILTER Feb 1996 Cs-137

<2.4

-0.31 +/- 2.53

<10.0 SPAP~12 AIR FILTER Feb 1996 Gr. Beta

<0.4 0.32 +/-0.29

<3.2 SPW-627 WATER Feb 1996 Co-liO

<3.0 1.70 +/- 1.fiO

< 10.0 SPW-627 WATER Feb 1996 Cs-134

<2.S

-0.36+/-1.66

< 10.0 SPW-627 WATER Feb 1996 Cs-137

<3.2 033.+/-1.fiO

<10.0 SPW-627 WATER Feb 1996 Gr. Alpha

<1.0 0.20 +/-0.93

< 1.0 SPW-627 WATER Feb 1996 Gr. Beta

<3.2 2.26+/-1.76

<3.2 SPW-627 WATER Feb 1996 1-131

<0.4

-0.21 +/- 032

<0.S SPW-628 WATER Feb 1996 Co-liO

<2.6

-1.38 +/- 2.18

<10.0 SPW-628 WATER Feb 1996 Cs-134

<3.1 0.95 +/-2.11

-< 10.0 SPW-628 WATER Feb 1996 Cs-137

<3.8 0.55 +/- 2.31

<10.0 SPW-628 WATER Feb 1996 1-131

<0.S

-0.18 +/-035

<0.5 SPW-629 WATER Feb 1996 H-3

<197

-12.47 +/- 97.17

<200.0.

SPMI-630 MILK Feb 1996 Co-liO

<3.5 1.26+/-1.79

<10.0 SPMI-630 MILK Feb 1996 Cs-134

<2.5

-0.12 +/- 1.53

<10.0 SPMI-630 MILK Feb1996 Cs-137

<2.6 0.22+/-1.44

<10.0 SPMI-630 MILK Feb 1996 1-131

<0.3

-0.07 +/-0.24

<0.5 SPMl-630 MILK Feb 1996 Sr-89

<0.9

-0.20+/-1.27

<5.0 SPMI-630 MILK Feb 1996 Sr-90 NIA 1.48 +/-0.40

<1.0 Low level of Sr-90 concentration in mi.lit (1-5 pCl/L) is not unusual.

SPVE-1069 VEGETATION Feb 1996 1-131(g)

<0.012 0.00 +/-0.01

<20.0 SPW-3 WATER Mar 1996 Ra-226

<0.08

-0.00 +/-0.04

<1.0 SPW-3.

WATER Mar 1996 Ra-228

<0.9 0.47 +/-0.75

<1.0 SPW-4 WATER Apr1996 Ra-226

<0.06 0.09 +/-0.04

<1.0 SPMI-2218 MILK Apr1996 Cs-134

<4.8 2.52 +/-2.62

<10.0 SPMI-2218 MILK Apr 1996 Cs-137

<5.4

. 4.42 +/-3.00

<10.0 SPW-2220 WATER Apr 1996 QH,()

<2.9 0.95+/-1.58

<10.0 SPW-2220 WATER Apr1996 Cs-134

<2.1 1.47+/-1.64

<10.0 SPW-2220 WATER Apr1996 Cs-137

<1.9

-1.28+/-1.72

<10.0 SPW-2222 WATER Apr1996 Gr. Alpha

<0.2

-0.21 +/-0.97

<1.0 A4-1

Table A-4.

In-house "blank* samples.

Concentration pCi/L *.

Teledyne Results Acceptance Lab Sample Sample

~4.66 Sigma2 Criteria Code Type Date Analysis LLD Activity6 (4.66 Sigma)

SPW-2222 WATER Apr 1996 Gr. Beta

<2.8 2.26+/-1.57

<3.2 SPW-2224 WATER Apr 1996 H-3

<151

-101.30 +/- 70.18

<200.0 SPW-2284 WATER Apr 1996 1-129

<1.4 0.22 +/-0.84

< 1.5 SPW-2286 WATER Apr 1996 Fe-SS

<0.7

-0.07 +/-0.43

< l<XX>.O SPW-2288 WATER Apr 1996 Tc-99

<4.2 0.55 +/- 2.29

<10.0 SPF-3421 FISH May 1996 Co-60

<0.010 0.00 +/-0.01

<10.0 SPF-3421

  • FISH May 1996 Cs-134

<0.014

-0.00 +/-0.01

<10.0 SPF-3421 FISH May 1996 Cs-137

<0.015 0.01 +/-0.01

<10.0 SPW-3440 WATER May 1996 1-131

<0.1 0.()1 +/-0.20

<0.5 SPMJ-3442 MILK May 1996 1-131

<0.1

-0.07 +/-0.20

<0.5 SPW-6 WATER Jun 1996 Ra-228

<1.0 0.13+/-1.05

<l.O SPMI-4055 MILK

<8,7 2.51 +/-4.Sl

<10.0 SPMI-4055 MILK Jun 1996 Cs-134

<6.1 1.87 +/-337

<10.0 SPMI-4055 MILK Jun 1996 Cs-137

<5.3 1.82+/-11.80

<10.0

  • SPMI-4055 MILK Jun1996 I-131

<0.3 0.21 +/-0.24

<0.S SPMI-4055 MILK Jun 1996 Sr-89

<0.8 0.57+/-1.83

<5.0 SPMI-4055 MILK Jwt 1996 Sr-90 NIA 1.49 +/-0.44

<1.0 Low level of Sr-90 concentration in milk (1-5 pCl/L} is not unusual.

SPW-7.

WATER Jul 1996 Ra-228

<0.8

-0.05 +/-0.70

<1.0 SPAP-4751

  • AIR FILTER Jul 1996 Co-60

<2.7 1.26+/-1.44

< io.o SPAP-4751 AIR FILTER Jul 1996 Cs-134

<4.8 1.50+/-1.80

<10.0 SPAP-4751 AIR FILTER Jul 1996 Cs-137

  • <2.4 0.63+/-1.49

<10.0 SPW-4937 WATER Jul 1996 Co-60

<4.5

-0.25 +/-3.27

<10.0 SPW-4937 WATER Jul 1996 Cs-134

  • <5.S 0.34 +/-339

.<.10.0 SPW-4937 WATER Jul 1996 Cs-137

<5.7

-0.35 +/-3.43

<10.0 SPMI-4939 MILK Jul 1996 Co-60

<8.0 1.13 +/-4.73

<10.0 SPMl-4939 MILK Jul 1996 Cs-134

<7.2 1.80 +/-5.18

<10.0 SPMl-4939 MILK.

Jul 1996 Cs-137

<5.8 1.()4 +/-3.77

  • <10.0 SPW-4943 WATER Jul 1996 Fe-SS

<0.6 0.18 +/-0.35

<1000.0 SPF-4997 FISH Jul 1996 Co-60

<0.006 0.00 +/-0.00

<10.0 SPF-4997

. FISH Jul 1996 Cs-134

<0.006

-0.00 +/-0.01

<10.0 SPP-4997 FISH Jul 1996 Cs-137

<0.009 0.01 +/-0.01

<10.0 SPAP-5670 AIR FILTER Jul 1996 Gr. Beta

<0.4 0.80 +/-032

<3.2 SPW-8 WATER Aug 1996 Ra-226

<0.04 0.16 +/-o.m

<1.0 SPW-8 WATER Aug 1996 Ra-228

<1.0 0.44 +/-0.19

<1.0 SPW-9 WATER Sep 1996 Ra-226

<0.05 0.01 +/-o.m

<1.0 A4-2

Table A-4.

In-house "blank* samples.

Concentration pCi/L *.

Teledyne Results Acceptance Lab Sample Sample

~4.66 Sigrna2 Criteria Code Tvt>e Date Anal~sis LLD Activi~

6

! 4.66 Shzma}

SPW-7013 WATER Sep 1996 Sr~89

<1.8

-0.73+/-1.10

<5.0 SPW-7013 WATER Sep 1996 Sr-90

<0.5

-0.05 +/-0.21

< 1.0 SPW:..10 WATER Oct 1996 Ra-228

<1.0 0.80 +/-0.57

< 1.0 SPMI-7382 MIU<

Oct 1996 Cs-134

<3.1

-0.25 +/-2.62

< 10.0 SPMI-7382 MIU<

Oct 1996 Cs-137

<4.8 0.15 +/- 2.68

< 10.0 SPMI-7382 MIU<

Oct 1996 l-131(g)

<3.7

-1.61 +/-3.28

<20.0 SPMI-~.83 MIU<

Oct 1996 Cs-134

<5.7 0.28 +/-3.68

<10.0 SPMI-7383 MIU<

Oct 1996 Cs-137

<4.1

-1.83 +/- 3.63

<10.0 SPMI-7383 MIU<

Oct 1996 1-131

<0.4 0.18 +/- 0.23

<0.5 SPMI-7383 MILK Oct 1996 I-131(g)

<6.8 1.19 +/-4.~

<20.0 SPMI-7443 MILK Oct 1996 1-131

<0.4

-0.08 +/-0.17

<0.5 SPCH-7475 CHARCOAL Oct 1996 1*131(g)

<2.8

-1.58 +/- 12.74

<9.6 CANISTER SPAP-7477 AIR FILTER Oct 1996 Cs-137

. <2.2

  • o.oo +/-o.oo

<10.0 SPS0-7479 SOIL Oct 1996 Cs-134

<0.011 0.00 +/-0.00

<10.0 SPS0-7479 SOIL Oct 1996 Cs-137

<0.007 0.00 +/-0.00

< 10.0 SPAP-7527 AIR FILTER Oct 1996 Gr. Beta

<0.7 0.10 +/-0.45

<3.2 SPF-7505 FISH Oct 1996 QH,()

<0.016

-0.00 +/-0.01

<10.0 SPF-7505 FISH Oct 1996 Cs-134

. <0.017

-0.01 +/-0.06

<10.0 SPF-7505 FISH Oct 1996 Cs-137

<0.016

-0.00 +/-0.01

<10.0 SPW-8735 WATER Nov 1996 aHiO

<6.0

-0.14 +/-0.10

<10.0*

SPW-8735 WATER Nov 1996 Cs-134

<4.7

-0.53 +/- 7:69

<10.0' SPW-8735 WATER Nov 1996 Cs-137

<8.2 2.09 +/-4.63

<10.0 SPW-8735 WATER Nov 1996 Gr. Alpha

<0.3 0.15 +/-0.21

< 1.0 SPW-8735 WATER Nov 1996 Gr. Beta

<0.8

-0.41 +/- 0.52

<3.2 SPW-8739 WATER Nov 1996 H-3

<158 106.99 +/- 82.93

<200.0

  • Liquid sample results are reported in pCi/Liter, air filter sample results are in pCi/filter, charcoal sample results are in pCi/charcoal, and solid sample results are in pCi/kilogram.

b The a~vity repc:>rted ~ the net activity result A4*3

Table A-5.

In-house "duplicate'" samples.

Concentration in pCi/L' Lab Sample First Second Averaged Codel Date Anal ls is Result Result Result CF-20, 21 Jan, 1996 Gr. Beta 7.1423 +/- 0.2477 6.8880 +/- 0.1339 7.0152 +/- 0.1~

CF-20, 21 Jan, 1996 K-40 3.6750 +/- 0.3680 3.6536 +/- 0.1270 3.6643 +/- 0.1946 CF-20, 21 Jan, 1996 Sr-89

-0.0115 +/- 0.0138 0.0042 +/- 0.0097

-0.0001 +/- o.~

CF-20, 21 Jan, 1996 Sr-90 0.0057 +/- 0.0034 0.0045 +/- 0.0021 0.0051+/-0.0020 Ml-47,48 Jan, 1996 Cs-137

-1.6700 +/- 4.1200 2.7900 +/- 3.3500 0.5600 +/- 2.6550 Ml-47,48 Jan, 1996 1-131 0.0511+/-0.2159 0.0763 +/- 0.2()().5 0.06.37 +/- 0.1473 LW-103, 104 Jan, 1996 Co-60 0.2690+/- 1.6500 1.0900+/- 2.2400 0.6795 +/- 1.3911 LW-103, 104 Jan, 1996 Cs-134 0.4450+/- 1.5400 1.0400+/- 2.3800 0.7425+/- 1.4174 LW-103, 104 Jan, 1996 U-137 0.6930 +/- 1.5800 0.2970 +/- 2.2200 0.4950 +/- 1.3624 LW-103, 104 Jan, 1996 Gr. Beta 2.2440 +/- 0.5110 2.2050 +/- 0.5678 2.2245 +/- 0.3819 LW-103, 104 Jan, 1996 1-131 0.0550 +/- 0.2332 0.0721:t0.2983 0.0635 +/- 0.1893 LW-103, 104 Jan, 1996 l-131(g)

-3.9100+/- 6.2600 1.3800 +/- 12.<XXJO

-1.2650+/- 6.7673 LW-103, 104 Jan, 1996 K-40 78.6450 +/- 35.300>

99.3760 +/- 48.5000 89.0105 +/- 29.9931 CW-132, 133 Jan, 1996 Gr. Beta 1.7043+/- 1.2727

-0.2699+/- 1.1417 0.7172 +/- 0.8549 CW-132, 133 Jan, 1996 Gr. Beta 5.5009 +/- 1.6811 3.8880+/- 1.56.39

-4.6944 +/- 1.1480 Ml-70, 71 Jan, 1996 Co-60 1.2400+/- 4.2(,00 1.6800+/- 4.0900 1.4600 +/- 2.9528 MI-70, 71 Jan, 1996 U-137 0.3210+/- 3.2700 2.3700 +/- 3.4200 1.3455 +/- 2.36.59 MI-154, 155 Jan, 1996

. Co-60 1.5700+/- 25500

-0.4590 +/- 3.2500 0.5555 +/- 2.0655 Ml-154, 155 Jan, 1996 U-134 0.1120+/- 2.1800

-2.3100+/- 2.5900

-1.0990+/- 1.6927 MI-154, 155 Jan, 1996 U-137

-0.7350 +/- 2.0100 0.6920 +/- 2.8500

-0.0215 +/- 1.7437 Ml-154, 155 Jan, 1996.

1-131 0.0429 +/- 0.2521 0.0326 +/- 0.2410 0.0377+/- 0.1744 Ml -* 154, 155 Jan, 1996 l-131(g)

  • 1.2400 +/- 3.400>

0.0193 +/- 3.8500 0.6597 +/- 2.5682 Ml-154, 155 Jan, 1996 K-40 1,521.1000+/- 89.300>

1,628.40Xl +/- 122.<XXX>

1,574.7500+/- 75.5951 MI - 154, 155 -

Jan, 1996 Sr-89.

-0.5282 +/- 0.8162

-0.6.568 +/- 0.8029

-0.5925 +/- 0.5724 Ml - 154, 155.

Jan, 1996 Sr-90 0.8201 +/- 0.3348 0.9595+/- 0.3294 0.8898 +/- 0.2348 WW -180, 181 Jan, 1996 1-131 0.0000+/-0.1940

-0.0631+/-0.2130

-0.0315+/- 0.1440 MI-298,299 Jan, 1996 1~131 0.1096+/-0.210J 0.2322 +/- 0.2760 0.1709+/- 0.1737 MI-298, 299 Jan, 1996 K-40 1,579.0000+/- 177.000>

1,551.i'<XX) +/- 168.000>

1,565.3500+/- 122.0174 CW-355,356 Jan, 1996_ Gr. Beta 0.0868 +/- 0.9590

-0.3493 +/- 0.9041

-0.1312 +/- 0.6590 CW-355,356 Jan, 1996 Gr. Beta 2.3816+/- 1.2727

- 2.0620+/- 1.2550 2.2218 +/- 0.8937 SW-436,437 Jan, 1996 Co-60 0.1360+/- 1.0900 0.6880+/- 1.8700 0.4120 +/- 1.~22 SW-436,437 Jan, 1996 U-137 0.0782 +/- 1.2<XX>

1.6100+/- 1.8700 0.8441+/-1.1110 WW-500,501 Jan, 1996 H-3 21,035.5732 +/- 418.5372 20,597.1409 +/- 414.3977 20,816.3571 +/- 294.4906 swr -554, 555 Jan, 1996 Gr. Beta 2.8.534 +/- 0.540'2 3.1179 +/- 0.5254 2.9857 +/- 0.3768 SW -841,842

. Jan, 1996 K-40 65.()'260+/- 28.300>

118.9000+/- 57.7000 91.9630+/- 32.1332 SW - 479, 480 Feb, 1996 Gr. Beta 6.7187+/- 1.0111 7.8142 +/- 1.3095 7.2665 +/- 0.8272 MI-521, 522 Feb, 1996 Co-60

-1.0500 +/- 2.9400 0.0602 +/- 5.0000

-0.4949 +/- 2.9002 AS-1

Table A-5.

In-house "'duplicate" samples.

Concentration in pCi /L

  • lab Sample First Secord Averaged Codesb Date Anal rs is Result Result Result MI -521, 522 Feb, 1996 U-137

-0.7930 +/- 2.8100

-0.3920 +/- 3.4400

-0.5925 +/- 2.2209 MI - 521, 522 Feb, 1996 1-131 0.1131+/-03229 0.2232 +/- 0.2998 0.1682+/- 0.2203 MI-580, 581 Feb, 1996 C<HIO

-0.7660 +/- 2.7300 1.7200+/- 1.4800 0.4770+/- 1.5527 MI-580, 581 Feb,1996 Cs-137 0.5780+/- 2.2900 0.4440 +/- 1.2600 0.5110+/- 1.3069 LW - 7CIJ, 710 Feb, 1996 Gr. Alpha 0.0692 +/- 0.3694 0.4866 +/- 0.3667 0.2779 +/- 0.2600 LW - 7.CIJ, 710 Feb, 1996 Gr. Beta 1.6911+/-0.4163 1.9519+/- 0.4187 1.8215 +/- 0.2952 LW - 7CIJ, 710 Feb, 1996 H-3 37.4444+/- 74.3195

. 84.3897 +/- 76.400 60.9171 +/- 53.2954 Ml-600,604 Feb, 1996 1-131

-0.8566+/- 0.4141

-0.2433 +/- 0.2580

-0.5499 +/- 0.2440 Ml-600,604 Feb, 1996 I<-40 1,382.9000+/- 115.0000 1,335.300) +/- 175.<XXX>

1,359.1000 +/- 104.7020 WW-648, 649 Feb, 1996 1~131

-0.0626 +/- 0.26M

-0.0926 +/- 0.2831

-0.0776+/- 0.1951 MI-674,6~

Feb, 1996 1-131

-0.8.l34 +/- 0.4012

-0.1217 +/- 0.3926

-0.4776+/- 0.2807 Ml-674,675 Feb, 1996 I<-40 1,390.4000+/- 174.()(XX) 1,493.<iOOO +/- 166.0000 1,442.0000+/- 120.2414 WW -865, 866 Feb, 1996 1-131 0.1291+/-0.2170 o.~20 +/- 0.2136 0.1U%+/-0.1522 PW-932,!m Feb, 1996 UHiO 0.5120+/- 1.4900 0.3780 +/- 2.3900 0.4450 +/- 1.~2 PW-932,!m Feb, 1996 Cs-137 0.0738 +/- 1.6600 0.7260 +/- 3.0400 0.3999 +/- 1.7318 SW -911, 912 Feb, 1996 UHiO

-1.7(!00+/- 3.3100 1.0300 +/- 1.5400

-0.3650 +/- 1.8254 SW -911, 912 Feb, 1996 Cs-137

-0.2630 +/- 3.6(0)

-0.8940+/- 1.7500

-0:5785 +/- 2.00l swr -953, 954 Feb, 1996 Gr. Beta 2.5439 +/- 0.5217 2.2467 +/- 0.5131 2.3953 +/- 0.3659 LW -1037, 1038 Feb, 1996 Gr. Beta 2.1972 +/- 0.5293 3.0691+/-0.5242 2.9331+/-0.3725 LW - 1037, 1038 Feb, 1996 H-3 36.5277 +/- 94.7223 116.7583 +/- 97.9812 76.6430+/- 68.1407 CW-977, 978 Mar, 1996 Gr. Beta 0.7188+/-1.1771

-0;1223 +/- 1.0275 0.2983 +/- o.7812

  • ,cw -977, 978 Mar, 1996 Gr. Beta 3.9324 +/- 1.5560 3.1466+/- 1..5001 3.5395 +/- 1.0807 SW - 1467, 1468.

Mar, 1996 H-3 130.3215 +/- 81.H31 130.3215+/- 81.1431 130.3215 +/- 57.3768 SW - 1467, 1468 Mar, 1996 Sr-89

-0.0970+/-1.9887 '

-1.CIJ24 +/- 1.9042

-0.5947 +/- 1.3767 SW - 1467, 1468 Mar, 1996 Sr-90 0.5674 +/- 0.3439 0.8920 +/- 0.3422 0.7297 +/- 0.2426 Ml - 1Cl58, 1059 Mar, 1996 1-131

-0.3095 +/- 0.428'

-0.03(,0 +/- 0.4053

-0.1728 +/- 0.2949 Ml - 1058, 1059 Mar, 1996 I<-40 1,.500.<XXX> +/- 157.()(XX) 1,549.<XXX>+/- 156.<XXX>

1,524..5000+/- 110.6628 MI - 1058, 1059 Mar, 1996 Sr-89 0.5701+/-0.9417

-1.5144+/-1.2855

-0.4721 +/- 0.7967 Ml - 1058,_1()59 Mar, 1996 Sr-90 1.5357+/-0.3610 2.3692 +/- 0.5498 1.9525 +/- 0.3288 MI-1152, 1153 Mar, 1996 1-131 0.4478 +/- 0.6285.

0.1991+/-0.5613 0.3235 +/- 0.4213 Ml - 1152, 1153 Mar, 1996 I<-40 1,524.3000+/- 157.000>

. 1,358.8000 +/- 172.<XXXJ 1,441.5500+/- 116.4399 P-1175, 1176 Mar, 1996 H-3 160j848 +/- 82.4671 151.8191+/-82.0'162 156.3020 +/- 58.1750 LW -1213, 1214 Mar, 1996 Gr. Beta 2.2980 +/- 0.5989 2.6667 +/- 0.6178 2.4823 +/- 0.4302 LW -1213, 1214 Mar, 1996 H-3 92.3600+/- 97.1490 29.4770 +/- 94.5700 60.9185 +/- 67.7890 SW - 1282, 1283 Mar, 1996 H-3 82.3522 +/- 96.2415 36.8938 +/- 94.3559 59.6230 +/- 67.3896 LW - 1309, 1310 Mar, 1996 UHiO 2.9800+/-4.7CXX>

4.1400+/-2.4800 3.5600 +/- 2.657*

LW - 1309, 1310 Mar, 1996 Cs-13'

-0.1740+/- 3.5700 2.2000+/- 4.4100 1.0130+/- 2.8369 A.5.-2

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L' Lab Sample First Second Averaged Codesb Date Anal~sis Result Result Result LW - 13o9, 1310 Mar, 1996 Cs-137

-4.7600+/- 3.9(XX)

-1.0800 +/- 4.2200

-2.9200+/- 2.8731 LW - 1309, 1310 Mar, 1996. Gr. Beta 2.5861+/-0.5296 2.8938 +/- 0..5364 2.7400+/- 0.3769 LW - 1309, 1310 Mar, 1996 1-131 0.4437 +/- 0.5347 0.1485+/- 0.5179 0.2961+/-0.3722 LW-1309, 1310 Mar, 1996 I-131(g) 0.9870+/- 5.4900

-0.67li0 +/- 5.3400 0.1555+/- 3.8294 LW - 1309, 1310 Mar, 1996 K-40 104.7400+/- SU<XX>

85.(i(XX) +/- 56.5000 95.1700+/- 38.2921 LW - 1362, 1363 Mar, 1996 H-3 162.9285 +/- 99.8622 10'1.9647 +/- 97.6775 135.4466+/- 69.8451 LW - 1362, 1363 Mar, 1996 Sr-89

-1.0161+/-0.8768 0.2819+/-1.3918

-0.3671 +/- 0.8225 LW - 1362, 1363 Mar, 1996 Sr-90 0.7296 +/- 03269 0.0471+/-0.5074 0.3886 +/- 0.3018 F - 1446, 1447 Mar, 1996 C<HiO 0.0011 +/- 0,0096

-0.0021 +/- 0.0136

-0.0005+/- 0.000 F - 1446, 1447 Mar, 1996 Cs-134 o.oom +/- 0.(00 0.0026 +/- 0.0132 0.0015 +/- 0.0077 F-1446, 1447 Mar, 1996

'~-137 0.0193 +/- 0.0100 0.0114 +/- 0.0119 0.0154 +/- 0.0078 F-1446, 1447 Mar, 1996 Gr. Beta 1.9680+/- 0,0709 1.8487 +/- 0.0640 1.9084 +/- 0.0478 F - 1446, 1447 Mar, 1996 I-131(g)

-0.0619+/- 0.3550

-0.6810 +/- 0..5450

-0.3715 +/- 0.3252 F - 1446, 1447 Mar,1996 K-40

t. 96.52 +/- 0.3(8) 2.0071+/-0.3800 2.0012 +/- 0.2446 SW - 1537, 1538 Mar, 1996 H-3 141.6453 +/- 96.1270 175.2449 +/- 98.0905 158.4451 +/- 68.88()1 LW -1612, 1613
  • Mar, 1996 Co-(,()

3.5000+/-3.(BX}

0.6920 +/- 1.6200 2.0%0+/- 1.7400 LW - 1612, 1613 Mar,1996 Cs-134 1.4000 +/- 2.6700 1.5800 +/- 1.9600 1.4900+/- 1.6561 LW -1612, 1613 Mar, 1996 Cs-137 4.7100+/- 3.()200 1.3100+/- 2.4100 3.0100+/- 1.9319 LW - 1612, 1613 Mar,1996 'Gr. Beta 2.6122+/-05460 3.0068 +/- 0.5285 '

2.8095 +/- 0.3799 LW - 1612, 1613 Mar, 1996 1-131 0.2556+/-0.1548 0.0982 +/- 0.1470 0.1769+/- 0.1067 LW - 1612, 1613 Mar, 1996. l-131(g) 0.2750 +/- JjlOO 0.7110 +/- 2.8600 0.4930 +/- 2.3422 LW - 1612, 1613 Mar,1996 K-40 61.2000 +/- 33. l<XX>

98.J<XX) +/- 31.4000 79.7500+/- 22.8121 cw -1709, 1710 Mar, 1996 Gr. Beta 4.4929 +/- 1.6917 3.5791 +/- 1.6536 4.0360 +/- 1.1828 cw -1709, 1710 Mar, 1996 Gr. Beta 0.4362 +/- 1.4668 0.2828+/-1.4.589 0.3595 +/- 1.0044 AP-2140, 2141 Mar,1996 Sr-89 0.0001 +/- O.DOO'l

-0.000'2 +/- 0.000'7

-0.0001 +/- O.CXX>S AP-2140, 2141 Mar, 1996 Sr-90 0.0000 +/- O.ooo2 O.(XX)l +/- 0.000'2 0;0001 +/- O.<XX>l WW -16.59, 1660 Mar, 1996 Co-a>

0.1%0 +/- 3.2100 2.2100+/- 2.5200 1.2<X30+/- 2.04U?

WW - 16.59, 1660 Mar, 1996 Cs-137

-1.8700+/-3.2800 2.2li00 +/- 2.4400 0.1950 +/- 2.0440 WW - 16.59, 1660 Mar, 1996 H-3 995.7658 +/- 117.5351 1,115.3290+/- 121.1114 1,05.5.5474 +/- 84.38.38 PW - 1757, 1758 Mar, 1996 H-3

'88.5534+/- 119.6998 68.8749 +/- 119.a511 78.7141+/-84.4115 AP-2547, 2548 Mar, 1996 Co-(,()

O.OO<M +/-'O.ooo6

-0.000'2 +/- 0.0006 0.0001 +/- 0.000&

AP-2547, 2548 Mar,1996 Cs-137

-0.0001+/-0,0006 O.two+/- 0.0006

-0.0000+/- 0.000&

AP - 2568, 2569 Mar,1996 Co-a>

o.oons +/- o.ows O.<XX>O +/- O.OO<<M o.0003 +/- o.ron AP - 2568, 2569 Mar, 1996 Cs-137

-0.0004 +/- 0-'Xm

-0.0002 +/- O.OO<<M

-0.0003 +/- O.IXX>3 MI - 1778, 1779 Apr, 1996 1-131 0.1746+/- 0.2116 0.0752 +/- 0.1924 0.1249 +/- 0.1430 MI - 17?8, 1779 Apr, 1996 K-40 1,390.4000+/- 98.l(XX) 1,426.<Xm +/- 144.CXXX>

1,408.2000+/- 87.1200 MI - 17?8, 1779 Apr, 1996 Sr-89*

-3.0921 +/- 2.1421

-1.3987 +/- 1;9624

-2.2454 +/- 1.4526 A.5-3

Table A-5.

In-house "duplicate* samples.

Concentration in pCi/L*

Lab Sample First Second Averaged c

.. odel Date Anal~is Result Result Result MI-1778, 1779 Apr, 1996 Sr-90 2.2153 +/- 0.5049 1.9830+/- 0.4425 2.0991 +/- 0.3357 MI - 1799, 1800 Apr, 1996 Co-60 0.1740+/- 2.6900 1.8900+/-4.5800 1.0320 +/- 2.6558 MI -1799, 1800 Apr, 1996 Cs-137 2.asoo +/- 2.4200 1.7500+/-3.1500 1.9<XX>+/- 1.9861 MI - 1799, 1800 Apr, 1996 1-131 0.1298 +/- 0.2421 o.1ns3 +/- 0.2114 0.1176+/- 0.1607 MI - 1843, 1844 Apr, 1996 1-131 0.0149 +/- 0.2136 0.0570 +/- 0.2205 0.0359 +/- 0.1535 MI - 1843, 1844 Apr, 1996 K-40 1,429.1000+/- 93.2000 1,630.3000 +/- 143.<XXX>

1,529.7000 +/- 85.3452 LW -.1913, 1914 Apr, 1996 Co-60 2.2100 +/- 0.7960 1.1500+/-3.2300 1.6800 +/- 1.6633 LW - 1913, 1914 Apr, 1996. Cs-134 0.4140 +/- 0.8110

-0. 7650 ~ 3.0700

. -0.1755+/- 1.5877 LW -1913, 1914 Apr, 1996 Cs-137 0.5290+/- 0.8890 O.!"D70 ::: 3.0900 o.s 180 +/- 1.(,()77 LW - 1913, 1914 Apr, 1996 Gr. Beta 3.m35 +/- 0.5461 2.t..S22 :: 0.5491 2.8478 +/- 0.3873 LW - 1913, 1914 Apr, 1996 1-131 0.0606 +/- 0.236' 0.0603 +/- 0.2573 0.0605+/- 0.1747 LW - 1913, 1914 Apr, 1996 l-131(g)

-0.2280+/- 1.7100

-1.6800 +/- 5.3900

-0.9540 +/- 2.8274 '

LW - 1913, 1914 Apr, 1996 K-40 39.4200 +/- 17.4000 86.9000 +/- 43;4000 63.1600+/- 23.3791 S0-1946, 1947 Apr, 1996 Cs-137 0.1859 +/- 0.()210 0.1768 +/- 0.0201 0.1813 +/- 0.0168 so -1946, 1947 Apr, 1996 K-40 10.4690+/- 0.4820 10.4630 +/- 0.3570 10.4<<i0 +/- 0.2999 cw -1991, 1992 Apr, 1996 Gr. Beta 3~+/-1.6711 4.6004 +/- 1.7163 4.2271+/-1.1977 cw -1991, 1992 Apr, 1996 Gr. Beta

-0.2825+/- 1.4171 0.2820+/- 1.4546

-0.0003 +/- 1.0154 WW - 1890, 1891 Apr, 1996 Co-60 1.6200+/- 1.7500 0.1810+/- 2.2000 0.9005+/- 1.4056

.WW ~'1890, 1891 Apr, 1996 Cs-137

-0.5890 +/- 1.6900 0.1370+/- 2.5100

-0.2260+/- 1.5130 WW - 1890, 1891 Apr, 1996 H-3 538.1625+/- 97.1244 601.3.181 +/- 99.3811 569.i'Sm +/- 69.4798 WW - 2063, 2064 Apr, 1996 Gr. Beta 6.3139 +/- 07737 6.2909 +/- 0.8290 6.30'24 +/- 0.5670.

WW - 2063, 2064 Apr, 1996 H-3 69.4957+/- 78.1213 26.7729 +/- 76.2293 48.13-t.1 +/- 54.5753 MI-2~,2090 Apr, 1996 1-131 0.1583 +/- 0.2546 0.1536 +/- 0.2311 0.1559 +/- 0.1719 MI - 2aw, 2090 Apr, 1996 K-40 1,338.3000 +/- 180.0<XX>

.1,456.sax> +/- 160.<XXX) 1,397.4000+/- 120.4159 LW -2303, 2304 Apr, 1996 Co-60 1.9400+/- 2.9500 1.4800+/- 3.0400 1.7100 +/- 2.1180 LW -2303, 2306 Apr, 1996 Cs-137 0.8050 +/- 2.7200 0.9610 +/- 3.0000 0.8830 +/- 2.0247 LW -2303, 2306 Apr, 1996 Gr. Beta 3.7252+/- 1.2629 4.0921 +/- 1.300C 3.90)7 +/- 0.9063 MI - 2418, 2419 Apr, 1996 1-131 0.1925 +/- 0.4050 0.2006 +/- 0.2588 0.1966 +/- 0.2400 MI-2418, 2419

. Apr,1~

K-40 1,418.9000+/- 120.()(XX) 1,477.300) +/- 182.<XXX) 1,448.l<m+/- 109.<XXX)

SS

  • 2442, 2443 Ap~1996 Gr. Alpha 3.5711+/-3.9146 0.34.59 +/- 2.7137 1.9585 +/- 2.384.5 SS
  • 2442, 2443 Apr, 1996 Gr. Beta 5..5419+/-3.()134 8.6149 +/- 3.2661 7.0784 +/- 2.2424 SS - 2442, 2443 Apr, 1996 K-40 7.5398 +/- 0.2410 7.8097 +/- 0.2680 7.6748+/- 0.1822 SS
  • 2442, 2443 Apr, 1996 Sr-90 0.0110 +/- O.D097 0.0030 +/- 0.0042 0.0070 +/- 0.0053 SL
  • 2589, 2590 Apr, 1996 Cs-137 0.0521 +/- O.o297 o.0626 +/- o.mss 0.0577 +/- 0.0233 SL - 2589, 2590 Apr, 1996 K-40 4.1139 +/- 0.4900 3.2858 +/- 0.5080 3.6999 +/- 0.3529 WW
  • 2700, 2701 Apr, 1996 H-3

-13.8536 +/- 73.4156

-31.1707 +/- 72.5940

-22.5122 +/- 51.62Y SW

  • 2675, 2676 Apr, 1996 Co-(;()

-1.9100+/- 1.9100

-1.1500 +/- 2.8600

-1.5300+/- 1.7196

Table A-5.

In-house "duplicate'" samples.

Concentration in pCi/L 1

Lab Sample First Second Averaged Codab Date Anall::sis Result Result Result SW - 2675, 2676 Apr, 1996 Cs-137

-1.0100 +/- 2.200) 3.0100+/- 2..5900 1.()(XX) +/- 1.6991 SW - 2503, 2504 Apr, 1996 I<-40 95.8880 +/- 4 7.8CXX) 71.0460 +/- 36.8000 83.4670+/- 30.1624 LW-2'm,2778 Apr, 1996 Co-60 3.1300 +/- 3.700) 1.8900 +/- 2.7700 2.5100+/- 2.3110 LW-2'm,2778 Apr, 1996 Cs-134

. -1.0500+/- 2.5100

-1.4600 +/- 2.5400

-1.2550 +/- 1.7855 LW-2'm,2778 Apr, 1996 Cs-137 0.3840 +/- 3.2600 2.4900 +/- 3.1300 1.4370+/- 2.2597 LW-2'm,2778 Apr, 1996 Gr. Beta 2.72~+/-0.6414 2.2112 +/- 0.6169 2.4658 +/- 0.4449 LW-2'm,2778 Apr, 1996 1-131,._

0.1973.+/- 0.2628

-0.1244 +/- 0.4231 0.0365 +/- 0.2490 LW-2'm,2778 Apr, 1996 I-131(g) 2.0800+/- 10.Jro)

-1.7600+/- 11..5000 0.1600+/- 7.7191 LW-2'm,2778 Apr, 1996 I<-40 91.0650+/- 43.2<XX>

59.7<XX> +/- 37.<XOO 75.3825 +/- 28.4396 F - 2612, 2613 May, 1996 Co-60 0.0020 +/- 0.0070 0.0031 +/- 0.0137 0.0026 +/- 0.0077 F - 2612, 2613 May, 1996 Cs-137 0.0004 +/- 0.0059 o.~2 +/- 0.0128 0.0043 +/- 0.0071 BS - 2654, 2655 May,1996 Gr. Beta.

4.6997+/- 1.7758 5.9663 +/- 1.8980 5.3330+/- 1.2996 BS - 2654, 2655 May, 1996 I<-40 6.4406 +/- 0.4180 6.6513 +/- 0.3510 6.5460 +/- 0.2729 BS - 2654, 2655

  • May, 1996 Sr-89 0.0115 +/- 0.0275 0.0076+/- 0.0247 0.0096 +/- 0.018.5 BS - 2654, 2655 May, 1996 Sr-90 0.0021 +/- 0.0058 0.0010 +/- 0.0053 0.0015 +/- 0.0039 F -26.33, 2634 May, 1996 Co-60 0.0077 +/- 0.0135 0.0041 +/- 0.0068 0.0059 +/- 0.0076 F -26.33, 2634 May, 1996 Cs-137 0.0075 +/- 0.()()79 0.0025 +/- 0.0064.

0.005() +/- 0.0051 MI-2742, 2743 May, 1996 co-a>

-1.6100 +/- 3.2100 0.2250 +/- 2.7200

-0.6925+/- 2.1037 MI - 2742, 2743 May, 1996 Cs-137 0.6880+/- 2.6100

-0.5110 +/- 2.3400 0.0885 +/- 1.7527 MI - 2742, 2743 May, 1996 1-131

-0.026.l +/- 0.2140 0.2399 +/- 0.2578 0.1068+/- 0.1675 MI* 2841, 2842 May, 1996 Co-60 2.0600 +/- 3.3400 0.4630 +/- 3.6400 1.2615 +/- 2.4701 MI* 2841, 2842 May, 1996 Cs-137 0.4460 +/- 2j600 3.3300 +/- 3.4000 1.8880+/- 2.1896 MI* 2841, 2842 May, 1996 1-131 0.3926 +/- 0.2720

-0.0419 +/- 0.2320 0.1754 +/- 0.1788 WW* 2866, 2867 May, 1996 Gr. Beta 6.8885+/- 1.3446 6.9243 +/- 1.3471 6.9064 +/- 0.9517 WW

  • 2866, 2867 May, 1996 H-3 178.3372 +/- 87.5017 133.7529 +/- 8.5.5877 156.0450 +/- 61.2001 LW
  • 2981, 2982 May,1996 Co-60 1.9400+/- 2.4500 0.7540+/- 1.9900 1.3470+/- 1.5782.*

LW-2981, 2982 May,1996 Cs-134 0.8040 +/- 2.3500 0.1(,6() +/- 1. 9900 0.4&50 +/- 1.5397 LW

  • 2981, 2982 May, 1996 Cs-137 2.2400+/- 2.6900

-0.7880+/- 2.1600 0.72(,() +/- 1.7249 LW

  • 2981, 2982 May, 1996 Gr. Beta 3.7095 +/- 0.6063 2.5867 +/- 0.5678 3.1481 +/- 0.4153 LW
  • 2981, 2982 May,_1996 1-131

-0.0178 +/- 0.2116 o.~18 +/- 0.2280 0.0170+/- 0.1555 LW

  • 2981, 2982 May, 1996 l-131(g) 1.9100+/- 8.8900

-2.9600+/- 7.2900

-0.5250+/- 5.7484 LW

  • 2981, 2982 May, 1996 I<-40 121.oox>+/- 38.6m>

150.700) +/- 23.3000 135.8500 +/- 22.5436 F

  • 2887, 2888 May,1996 Co-60 0.0025 +/- 0.0074

-0.0067 +/- 0.010'1

-0.0021+/-0.0065 p

-0.0003+/-0~

o.ron +/- o.0083 0.0045 +/- 0.0050

. WW* 3032, 303.l May,1996 Gr. Beta 3.5731+/-0.8840 25'37 +/- 0.5356 3.0584 +/- 0.5168 WW

  • 3032, 303.l May,1996 H-3 32.0189 +/- 83.886' 133.6172 +/- 88.2476 82.8181 +/- (,().8781

$. 2931, 2932 May, 1996 Cs-137 0.2016+/- 0.0948 0.1473 +/- o.ms2 0.1745+/- 0.0506 AS-5

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L9 Lab Sample First Secord Averaged Codesb Date Anal ls is Result Result Result SS - 2931, 2932 May, 1996 K-40 21.4470 +/- 1.7600 18.8680 +/- 0.9850 20.1575+/- 1.0034 cw -2955, 2956 May, 1996 Gr. Beta 2.6457 +/- 1..5687 3.6434 +/- 1.6186 3.1445+/- 1.1270 cw -2955, 2956 May, 1996 Gr. Beta

-0.3404 +/- 1.1161

-0.4374 +/- 1.1068

-0.3889 +/- 0.7859 Ml - 3053, 3054 May, 1996 Sr-89 0.5734 +/- 1.5144

-0:5940 +/- 1.9757

-0.0103 +/- 1.2447 MI - 3053, 3054 May, 1996 Sr-90 1.3596+/- 0.4076 1.9168 +/- 0.5433 1.6.382 +/- 0.3396 Ml-3099, 3100 May, 1996 Co-60 0.3260 +/- 2.6800 0.3250+/- 4.3100 0.3255 +/- 2.5376 MI-3099, 3100 May, 1996 Cs-137

-0.5550 +/- 2..5400

-0.8250 +/- 3.6300

-0.6900+/- 2.2152 Ml - 3()99., 3100 May, 1996 1-131 0.0000 +/- 0.2849 0.1521 +/- 0.2367 0.0761 +/- 0.1852 F -3251, 3252 May, 1996 K-40 2.6265 +/- 0.3740

-2.7477 +/- 0.2620 2.6871 +/- 0.2283 BS - 3230, 3231 May, 1996 Cs-137 0.5~+/-0.0415 0.6.314 +/- 0.0479 0.6111+/-0.0317 BS -3230, 3231 May,1996 K-40 22.4440 +/- 0.8280 21.8090 +/- 0.8310 22.1265 +/- 0.5865 MI -3344, 3345 May, 1996 1-131 0.1825 +/- 0.2236 0.1735 +/- 0.2762 0.1780+/- O.lm MI - 3344, 3345 May, 1996 K-40 1,611.2000+/- 190.0<XX>

1,409.500>+/- 157.0000 1,510.3500+/- 123.2366 VE-3381, 3382 May, 1996 Gr. Alpha 0.445.3 +/- 0.1729 0.4370+/- 0.1764 0.4411+/-0.1235 VE - 3381, 3382 May, 1996. Gr. Beta 4.2583+/-0.2415 4.0142 +/- 0.246.5 4.136.3 +/- 0.1725 VE - 3381, 3382 May, 1996 K-40 4.5676 +/- 0.2820 4.1093 +/- 0.3490 4.3385 +/- 0.2243 swu -3404, 3405 May, 1996 Gr~ Beta 2.5210+/- 0.5256 3.1121+/-0.5527 2.8165 +/- 0.3811 swu -3404, 3405 May, 1996 H-3 197.5959 +/- 88.4614 188.3624 +/- 88.0751 192.9792+/- 62.41!>...

SW - 3677, 3678 May, 1996 Co-60 0.4910+/- 2.4(0) 0.1600+/- 1.7800 0.3255 +/- 1.4940 SW - 3677, 3678 May, 1996 Cs-137 1.1600 +/- 3.4(0)

-0.6680 +/- 2.1900

. 0.2460 +/- 2.0221 SW - 3677, 3678 May, 1996 Gr. Beta

_5.3891 +/- 1.3003 6.0224 +/- 1.2717 5.7(1';7 +/- 0.91n5 ow -3551, 3552 May,1996 Gr. Beta 2.7774+/-0.5358 1.8916 +/- 0.4948 2.334.5 +/- 0.3647 ow -3551, 3552 May, 1996 1-131 0.3093 +/- 0.3725 O.(XX)() +/- 0.3989 0.1547 +/- 0.2729 ow -3551, 3552 May, 1996 K-40 113.1400 +/- 47.8CXXJ 131.5000+/- 74.9000 122.3200+/- 44.4265 WW ~ 3506, 3507 May,1996 H-3 3.0953 +/- 81.2184

-32.1916 +/- 79.5882

-14.5481+/-56.8566.

PW -3700, 3701 May,1996 Co-60 0.8910+/- 2.2100

-0.4110 +/- 3.0700 0.2400 +/- 1.8914 PW - 3700, 3701 May,1996 Cs-137

-1.6500+/- 2.5300 0.2960 +/- 3.1700

-0.6770 +/- 2.0'279 MI - 3447, 3448 Jun, 1996 Co-60

-0.5800 +/- 4.8900

-1.2600 +/- 4.7500

-0.9200+/- 3.4086 MI - 3447, 3448 Jun, 1996 Cs-137 0.7550+/- 3.5900 2.6200+/- 3.9300 1.6875+/- 2.6614 MI - 3447, 3448 Jun, 1996 1-131

-0.0354 +/- 0.1423

-0.07~ +/- 0.284.5

_ -0.0531+/-0.1590 G -3530, l531 Jun, 1996 Gr. Beta 4.1514 +/- 0.()918 4.9200+/- 0.0996 4.8357 +/- 0.0698 G -3530, l531 Jun, 1996 K-40 4.9488 +/- 0.5170 4.5401 +/- 0.4480 4.744.5+/- 0.3421 G-3530, 35.31 Jun, 1996 Sr-89 O.OOU +/- O.oo56

-0.0006 +/- 0.0057 0.0017 +/- 0.0040 G-3530, 35.31 Jun, 1996 Sr-90 0.0000 +/- 0.0013 O.CXX>9 +/- 0.0014 O.c:Kn; +/- O.<XX>9 WW - 3597, 3598 Jun, 1996 Gr. Beta 2.6521 +/- 0.1188 1.6547 +/- 0.6666 2.1534 +/- 0.490'2 WW - 3597, 3598 Jun, 1996 H-3 114.94.57 +/- 80.8320 107.8722 +/- 80.5219 111.4089+/- 57.04"-

G - 3621, 3622 Jun, 1996" K-40 5.5191+/-0.1840 5.6649 +/- 0.2200 5.5920+/- 0.143-.

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L' lab Sample First Second Averaged Codesb Date Anal~sis Result Result Result M1 -3642, 3643 Jun, 1996 1-131

-0.2191+/-0.3434 0.2403 +/- 0.3137 0.0106 +/- 0.2326 F-445~ 4453 Jun, 1996 Cs-137 0.0147 +/- 0.()()58 0.0120 +/- 0.0047 0.0133 +/- 0.0037 F -4452, 4453 Jun, 1996 Cs-137 0.0147 +/- 0.0058 0.0120 +/- 0.0047 0.0133 +/- 0.0037 F -4452, 4453 Jun, 1996 Gr. Beta 2.1435 +/- 0.1120 2.1090+/- 0.1050 2.1262 +/- 0.0767 F -4452, 4453 Jun, 1996 Gr. Beta 2.1435 +/- 0.1120 2.1090 +/- 0.1050 2.1262 +/- 0.0767 F -4452, 4453 Jun, 1996 K-40 1.9188 +/- 0.1070 2.0107 +/- 0.1()(,()

1. 9648 +/- 0.0753 F -4452, 4453 Jun, 1996 K-40 1.9188 +/- 0.1070.

2.0107 +/- 0.1()(,()

1.9648 +/- 0.0753 Ml-3830, 3831 Jun, 1996 1-131.

O.CX373 +/- 0.4959 0.1570 +/- 0.4625 0.0972 +/- 0.3391 Ml-3830, 3831 Jun, 1996 K-40 1,544.7000+/- 111.000>

1,447. l<XX) +/- 159.CXXX) 1,495.9000+/- 96.9562 M1 - 3773, 3774 Jun,1996 Co-60 1.3400 +/- 2.9800 2.5300+/- 3.1800 1.93.50+/- 2.1790 M1 - 3773, 3774 Jun, 1996 Cs-137 3.7800 +/- 2.6400

-0.3320 +/- 2.6000 1.7240+/- 1.8527 M1 - 3773, 3774 Jun, 1996 1-131 0.1664+/-,0.3100

-0.1240 +/- 0.4621 0.0212 +/- 0.2782 MI - 3874, 3875.

Jun, 1996 Sr-89

-2.1430+/- 1.8964

-1.3467 +/- 1.933o

-1.7448+/- 1.3540 MI - 3874, 3875 Jun, 1996 Sr-90 2.3113 +/- 0.5587 2.3694 +/- 0.5928 2.3403 +/- 0.4073 G -3918, 3919 Jun, 1996 K-40 6.6922 +/- 0.2270

. 7.1444 +/- 0.2770 6.9183+/- 0.1791 G -400, 4046 Jun, 1996 K-40 4.7112 +/- 0.5300 5.1352 +/- 0.3330 4.9232 +/- 0.3130 swu -4092, 4093 Jun, 1996 Gr. Beta 2.3788 +/- 0.6583 1.9279 +/- 0.6369 2.1533 +/-, 0.4580 swu -4092, 4093 Jun, 1996 H-3 208.0150 +/- 84.{681 223.9706+/- 85.4329 215.9928+/- 60.1756 MI - 4071, 4072 Jun, 1996 1-131

-0.1101 +/-0..5660

-0.1326 +/- 0.5298

-0.1214 +/- 0.3876 MI - 4071, 4072 Jun, 1996 K-40 1,229.3000+/- 142.000>

1,512.l<XX>+/- 143.CXXX>

1,370.7000 +/- 100.7633 MI -4071, 4072 Jun, 1996 Sr-89 0.2841 +/- 1.o223

-0.4201 +/- 1.2371

-0.0680 +/- 0.802.4 MI - 4071, 4072 Jun, 1996 Sr-90 0.9516+/-0.3157 1.2585 +/- 0.3851 1.1050+/- 0.2490 WW - 4113, 4114 Jun, 1996 1-131 OJJ17l +/- 0.5375 0.2762 +/- 0.5142 0.1710+/- 0.3719 SW* 4162, 4163 Jun, 1996 H-3 13.3915 +/- 75.3848 6.2494 +/- 75.0457 9.82Q5+/- 53.1853

'f'W - 4215, 4216 Jun.1996

. H-3 58.4.305 +/- 80.8304 104.2785+/- 79.1202 81.3545 +/- 56.5543 LW

  • 4259, 4260 Jun.1996 H-3 195.8174 +/- 86.1367 215.2812+/- 86.9327 205.5493+/- 61.1899

'f'W

  • 4549, 4550 Jun.1996 Co-60.

-0.4630+/- 1.4CXX>

-0.3690 +/- 1.5300

-0.4160+/- l.Cl369 PW* 4549, 4550 Jun, 1996 Cs-137

-1.1200+/- 1.7200

-0.6960 +/- 1.9900

-0.9080+/- 1.3152 SW - 4406, 4407.

Jun, 1996. Co-60

-0.9280 +/- 1.9500

-0.2850 +/- 2.6100

-0.6065 +/- 1.6i90 SW

-0.3900+/- 2.4300 2.5700 +/- 2.9300 1.0900+/- 1.9003 E

  • 4284, 4285 Jul, 1996 Gr. Beta 1.0430+/- O.o595 1.1245 +/- 0.0648 1.0837 +/- 0.0440 E - 4284, 428.5 Jul, 1996 K-40 1.1372 +/- 0.1830 1.1588 +/- 0.1160 1.1480+/- 0.100 E
  • 4284, 4285 Jul, 1996 Sr-89 0.0019 +/- o.oou 0.0016 +/- 0.0045 0.0017 +/- 0.0032 E - 4284, 4285 Jul, 1996 Sr-90

-0.0001+/-0.0011 0.0003 +/- 0.0010 0.0001 +/- 0.0007 WW

  • 4305, 4306 Jul, 1996 Gr. Beta 1.1828 +/- 0.3499 1.2369 +/- 0.3447 1.2098 +/- 0.2456 Ml
  • 4326, 4321 Jul, 1996 Co-60

-0.1700+/- 2.9800

-1.0600+/- 3.4400

-0.6150+/- 2.2756 Ml

-0.0644 +/- 2.6300 2.0100 +/- 2.9700 0.9728 +/- 1.9835 AS-1

Table A-5.

In-house "duplicate'" samples.

Concentration in pCi/L' Lab Sample First Second Averaged Codesb Date Anal rs is Result Result Result p - 4431, 44.32 Jul, 1996 H-3 24.8404 +/- 71.8799 110.9537 +/- 75.7439 67.8970 +/- 52.2108 AP - 4595, 4596 Jul, 1996 Sr-89 0.0015 +/- 0.()()'29

-0.0022 +/- 0.0030

-0.0004 +/- 0.0021 AP - 4595, 4596 Jul, 1996.

Sr-90 o.~ +/- 0.<>006 0.0002 +/- 0.0007 0.0005 +/- 0.00)4 WW - 4375, 4376 Jul, 1996 Co-(iO 1.3000+/- 2.1300 1.1800+/- 2.4300 1.2400+/- 1.6157 WW - 4375, 4376 Jul, 1996 Cs-137 1.1100+/- 2.2700 1.0200+/- 2.8700 1.0650 +/- 1.8296 WW - 4375, 4376

-30.7552 +/- 76~9153.

-25.4322 +/- 77.1605

-28.0937+/- 54.4741 MI - 45CX3, 4504 Jul, 1996 1-131

--0.0390 +/- 0.2814 0.1693 +/- 0.2869 0.0652 +/- 0.2009 MI -45CX3, 4504 Jul, 1996 J(-40 1,287.1000+/- 161.()(XX) 1, 188.300)+/- 136.CXXX>

1,237.7000 +/- 105.3767 MI - 45CX3, 4504 Jul, 1996 Sr-89

-1.497 4 +/- O.%ffi

-1.7702 +/- 1.2061

-1.6338 +/- o.7709 MI - 45CX3, 4504 Jul, 1996 Sr-90 1.5658 +/- 0.5270 2.4509 +/- 0.5124 2.0084 +/- 0.3675 MI - 4527, 4528 Jul, 1996 Co-(,()

2.3600 +/- 2.5400

. -1.2100+/- 2.6300 0.5750 +/- 1.8281.

MI-4527, 4528 Jul, 1996 Cs-134 0.7910+/- 1.9100 1.9000+/- 2.5500 1.3455 +/- 1.5930 MI -4527, 4528 Jul, 1996 Cs-137

-0.6890 +/- 2.0000 0.0613 +/- 2.2900

-0.3139 +/- 1.5301 MI - 4527, 4528 Jul, 1996 1-131 0.1910+/- 0.4532 0.0901+/-0.4519 0.1406+/- 0.3200 MI -4527, 4528 Jul~ 1996 I-131(g)

-0.0570 +/- 2.8300 0.1290 +/- 3.5800 0.0360 +/- 2.2817 MI -4527, 4528.

. Jul, 1996.

J(-40 1,419.1000 +/- 91.300) 1,Q.(,00) +/- 10'7.CXXX>

1,413.~ +/- 70.3290 MI -4527, 4528 Jul, 1996 Sr-89

-0.3720+/- 1.0231

-1.46G5+/- 1.1500

--0.9162 +/- 0.769f MI -4527, 4528 Jul, 1996 Sr-90 1.n524 +/- 0.2300 1.3388 +/- 0.2716

. 1.1956+/- 0.1780 WW - 4684, 4685 Jul, 1996 H-3

-30.7174 +/- 76.820J

-12.9958+/- 77.6342

-21.8566+/- 54.~

WW - 48<ll, 480'J Jul, 1996 Gr. Beta 0.9983 +/- 1.2558 0.8849 +/- 1.2477 0.9416+/- 0.8852 WW - 4808, 480'J

. Jul, 1996 H-3

-15.0491 +/- 82.3946

-30.4456 +/- 72.1801

-22.7473+/- 54.9677 G -4762, 4763 Jul, 1996 J(-40 6.970'1+/-03420 7.2772 +/- 0.2280 7.1240 +/- 0.2055 LW - 4832, 483.1 Jul, 1996 Co-60

-1.1600+/- 1.6700 1.1600 +/- 1.8600 o.ocm+/- 1.2498 LW - 4832, 483.1 Jul, 1996 Cs-137 1.0200 +/- t.6300 1.6900 +/- 2.2400 1.3550 +/- 1.38.51 LW - 4832, 483.1 Jul, 1996 Gr. Beta 3.460'2 +/- O:JC'trl 3.3545 +/- 0.6948 3.40'14 +/- 0.4941 LW - 4832, 483.1 Jul, 1996 Gr. Beta 3.460'2 +/- O:JC'trl 3.3545 +/- 0.6948 3.40'14 +/- 0.4941 LW-5014, 5015 Jul, 1996 Gr. Beta 2.010'7 +/- 0.6109 2.0288 +/- 0.(,093 2.0197 +/- 0.4314 F -5515, 5S16 Jul, 1996 Cs-137 0.0534 +/- 0.0171 0.0522 +/- 0.0182 0.0528 +/- 0.0125 p - 5515, 5S16 Jul, 1996 Gr. Beta 2.5113 +/- O.o911 2.4617+/-0.~

2.4865 +/- 0.0643 F - 5515, 5S16 Jul, 1996 J(-&()

2.4049 +/- 0.2870 2.6688 +/- 0.3560 2.5369 +/- 0.2286 cw -4956, 4957 Jul, 1996 Gr. Beta 2.1830+/- 1.4513 3.9669 +/- 1.5535 3.0749 +/- 1.0630 cw -4956, 4957 Jul, 1996 Gr. Beta 0.5827 +/- 1.2131 0.2749 +/- 0.8554 0.4288 +/- 0.7422 SW - 5248, 5249 Jul, 1996 Co-60

-1.0000+/- 1.9100 0.1870 +/- 1.8700

-0.4065 +/- 1.336.5 SW - 5248, 5249 Jul, 1996 Cs-137 0.7590 +/- 2.2800

-0.5680 +/- 2.4400 0.0955 +/- 1.6697 WW - 5215, 5216 Jul, 1996 H-3 183A121+/-90.9893 317.9144+/- 96.0148 250.6632 +/- 66.1398 MI -SOil, 5082 Jul, 1996 Co-60 1.1900+/-3.()700

-1.7100+/-4.1800

-0.2600+/- 2.593' MI -SOil, 5<m Jul, 1996 Cs-137 0.4920 +/- 2.6(0)

-2.8800 +/- 3.3400

-1.1940+/- 2.116.>

AS-8

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L" Lab Sample First Second Averaged Codesb Date Anal~sis Result Result Result MI-5081, 5082 Jul, 1996 I-131 0.1808 +/- 0.5572 0.5417 +/- 0.6704 0.3613 +/- 0.4359 MI-5081, 5082 Jul, 1996 I-131 0.1808 +/- 0.5572 0.3699 +/- 0.6986 0.2754 +/- 0.4468 swu -5125, 5126 Jul, 1996 Gr. Beta

,.1217+/- 2.os.&3 5.5300 +/- 2.3022 4.8258 +/- 1.5427 swu -5125, 5126 Jul, 1996 H-3 176.3979 +/- 90.7067 125.7490 +/- 88.7348 151.0734 +/- 63.44(i()

VE - 5146, 5147 Jul, 1996 Gr. Beta 3.1394 +/- 0.10'26 3.0940 +/- 0.0683 3.1167 +/- 0.0616 VE - 5146, 5147 Jul, 1996 K-40 3.3818 +/- 0.1400 3.4692 +/- 0.1430 3.4255 +/- 0.1001 ow

  • 5269 I 5270 Jul, 1996 Gr. Beta 6.4711+/-1.3831 5.9871+/- 1.2673 6.2291+/-0.9379 ow -5269, 5270 Jul, 1996 I-131 0.2126+/- 0.3519 0.0404 +/- 0.3202 0.1265 +/- 0.2379 MI - 5168, 5169 Aug, 1996 1-131

-0.0474 +/- 0.4432

-0.6129 +/- 0.5327

-0.~2 +/- 0.346.5 Ml - 5168, 5169 Aug, 1996 K-40 1,585.8000 +/- 123.000) 1,534.400) +/- 162.0000 1,560.1000+/- 101.7018 MI - 5289, 5290 Aug, 1996 1-131

-0.0550 +/- 0..5Ql5

-0.3445 +/- 0.5937

-0.1998 +/- 0.3909 MI - 5190, 5191 Aug,1996 co-<io

-1.6400+/- 2j500

-0.1890 +/- 4.0300

-0.9145 +/- 2.4394 Ml - 5190, 5191 Aug,1996 Cs-137 0.1550 +/- 3.1400 0.6150 +/- 3.3900 0.3850+/- 2.3104 MI -5190, 5191 -

Aug, 1996 1-131 0.2155 +/- 0.4940 0.4414 +/- 0.4691 0.3285 +/- 0.3406 SL - 5424, 5425 Aug,1996 co-<io 0.0012 +/- 0.010'7 O.tml +/- 0.0085 0.0047 +/- 0.0068 SL - 5424, 5425 Aug, 1996 Cs-134 0.0089 +/- 0.()()94 0.0054 +/- 0.0084 0.0071 +/- 0.0063 -

SL - 5424, 5425 Aug, 1996 Cs-137 0.0028 +/- 0.0171 O.<l365 +/- 0.0149 0.0347 +/- 0.0113 SL - 5424, 5425 Aug,1996 l-131(g) 0.0005 +/- O.oo<M

-0.0166 +/- 0.0275

-0.0081+/-0.0205 SL - 5424, 5425 Aug, 1996 K-40 1.5671+/-0.2530 1.6391 +/- 0.2110 1.6034 +/- 0.1647 MI - 5386, 5387 Aug, 1996 co-<io O.i'970+/- 3.1900

-3.4000 +/- 4.8300

-1.3015 +/- 2.8942 MI - 5386, 5387 Aug,1996 Cs-137 1.1400+/- 2.6400 1.7500+/-3.4900 1.4450 +/- 2.1880 MI - 5386, 5387 Aug,1996 1-131 0.0065 +/- 0.1987

-0.0'211+/-0.2171

-0.0073 +/- 0.1472 MI - 5386, 5387 Aug, 1996 1-131 0.006.5 +/- 0.1987

-0.0271 +/- 0.2797

-0.0103 +/- 0.1716 swu -5905, 5906 Aug, 1996 Gr. Beta 1.4815 +/- 0.6624 -

2.4356 +/- 0.5278 1.9586 +/- 0.4235 swu -5905, 5906 Aug, 1996 H-3 257.1759 +/- 84.290'l 306.5672 +/- 86.2631 281.8715 +/- 60.3007 MI -5582, 5583 Aug, 1996 1-131 0.2361+/- 0.57~

-0.0245 +/- 0.5563 O.la58 +/- 0.3984 MI - 5582, 5583 Aug, 1996 K-40 1,473.(J(XX)+/- 180~

1,459.00)) +/- 152.0000 1,466.3000+/- 117.7964 LW - 5606, 5fl17 Aug, 1996 CcHiO 0.7330+/- 1.8200

-0.8030 +/- 1.5400

-0.0350+/- 1.1921

- LW - 5606, 5fl17 Aug, 1996.

Cs-137 0.4970 +/- 1.8900

-0.8750 +/- 2.5900

-0.1890+/- 1.6001 LW-5606, 5611 Aug,1996 Gr. Beta 5.4236+/- 1.2712 5.3355 +/- 1.2524 5.3i'95 +/- 0.8923 SL - 5667, 5668 Aug,1996 Cs-137 o.m 16 +/- 0.0139

- 0.0289 +/- 0.0152 o.0303 +/- o.01m SL-5667, 5668 Aug,1996 K-40 2.4446 +/- 0.2910 2.6982 +/- 0.2670 2.5714 +/- 0.1975 cw -5759, 5760 Aug,1996 Gr. Beta 3.7309 +/- 1.4739 4.5529 +/- 1.5367 4.1419+/- 1.0646 cw -5759, 5760 Aug, 1996 Gr. Beta 0.6563+/- 1.1139 0.6561+/-1.1136 0.6562 +/- 0.7876 MI - 5817, 5818 Aug, 1996 Co-(,(}

-4.3400 +/- 4.6(XX) 3.7100 +/- 4.8200

-0.3150+/- 3.3.314 MI-5817, 5818 Aug,1996 Cs-137

-0.6750+/- 4.2CXX>

1.3900 +/- 3.5700 0.3575 +/- 2.7561 Ml - 5817, 5818 Aug,1996 ( 1-131 0.0'287 +/- O.o732 o.~22 +/- o.0'769 0.0405 +/- 0.0531 AS-9

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/t

  • Lab Sample First Second Averaged

<:.odesb Date Anal~sis Result Result Result SWT - 5884, 5885

. Aug, 1996 Gr. Beta 2.713.5 +/- 0.7709 2.8640 +/- 0.7248 2.7888 +/- 0.5290 SW - 5925, 5926 Aug, 1996 Gr. Beta 3.5571 +/- 0.6476 3.7970+/-0.~

3.6770 +/- 0.5547 Ml - 5978, 5979 Aug,1996 1-131

-0.1138 +/- 0.5079 o.3nS+/-0.4119 0.1295 +/- 0.3270 Ml - 5978, 5979 Aug,1996 K...W 1,468.4000 +/- 179.()(XX) 1,560.S<XX> +/- 173.(XXX) 1,514.6000+/- 124.4689 VE - 5950, 5951 Aug; 1996 Co-60 0.0006 +/- 0.()()62 0.0028 +/- 0.0058 0.0017 +/- O.OOll VE - 5950, 5951 Aug,1996 Cs-137

-0.0006 +/- 0.0068 o.cxm +/- o.0047

-0.0002 +/- 0.0034 VE-6001, 6002 Sep, 1996 Gr. Beta 2.9014 +/- 0.()919 2.7239 +/- 0.183.1 2.8126 +/- 0.1025 VE-6001, 6002 Sep, 1996 K-40 3.2199 +/- 0.1950 3.3724 +/- 0.3060 3.2962 +/- 0.1814 VE-6001, 6002 Sep, 1996 Sr-89 0.0018 +/- O.oo24

-0.0004 +/- 0.0021 0.0007 +/- 0.0016 VE-6001, 6002 Sep, 1996 Sr-90 0.000'2 +/- 0.()007 0.0009 +/- 0.0007 o.0006 +/- o.cxn>

LW - 6052, 6053

  • Sep, 1996 Co-60 0.9250+/- 1.0SOO

. -0.5060+/- 1.5400

. 0.2095+/- 0.9319 LW - (,()52, 6053 Sep,1996 Cs-134 0.3430+/- 13200 0.8910 +/- 2.3000 0.6170 +/- 1.3259 LW - (,()52, 6053

.Sep, 1996 Cs-137 0.0'211+/-1.2900

-0.1280+/- 1.8600

-0.0535+/- 1.1318 LW - 6m2, 6053 Sep, 1996 Gr. Beta 2.1334 +/- 0j001.

3.0766 +/- 0.5583 2.6050 +/- 0.4489 LW - 6<m, 6053 Sep, 1996 1-131

-0.~9 +/- 0.3821 0.0180 +/- 0.3249

-0.1955+/-0.~

LW - 6052, 6053 Sep, 1996 I-131(g) 1.2200 +/- 6.0300 1.7000+/- 10.1000 1.4600+/- 5.8816 LW - 6052, 6053 Sep, 1996 K-40 66.8250 +/- 30.100>

43.6(XX) +/- 27.1000

. 55.2125+/- 20.25 1 ~

WW - 6181, 6182 Sep, 1996 Gr. Beta 1.6248 +/- 0.6211 1.0'281+/-0.(,056 1.3264 +/- 0.433, WW - 6181, 6182 Sep, 1996 H-3 5.3932 +/- 82j475 62.9206 +/- 8.5.2105 34.1568 +/- 59.3885 Ml - ()006, fJX1J Sep, 1996 1-131 0.0780+/- 0.30'76 0.0130 +/- 0.3110 0.0455 +/- 0.2187 MI - 6006, flXJ7 Sep, 1996 K-40 1,472.0000+/- 166.oool 1,50'2.9(XX) +/- 110.00X) 1,487.4500+/- 99.5691 cw -6128, 6129

  • Sep, 1996 Gr. Beta 4.6340 +/- 1.6130 4.5894+/- 1.6139 4.6117+/- 1.1409 cw -6128, 6129 Sep, 1996 Gr. Beta 4.6340+/- 1.6130 4.5894 +/- 1.6139 4.6117+/- 1.1409 cw -6128, 6129 Sep, 1996 Gr. Beta 0.2285+/- 1.1265 0.3197+/- 1.1117 0.2741+/-0.7913 SW - 62<M, 6205 Sep, 1996 H-3 113.2802 +/- 8.53728 61.4098 +/- 83.1710 87.3450 +/- 59.5943 MI - 6225, 6226 Sep, 1996 Co-liO 1.9300 +/- 2.8500

-0.5880 +/- 2.5900 0.6710+/- 1.9255 MI -6225, 6226 Sep, 1996 Cs-137 2.7700 +/- 2.1200

-0.2550 +/- 2.4700 1.2575 +/- 1.8371 MI - 6225, 6226 Sep, 1996 1-131

-0.2584 +/- 0.4450 0.2718 +/- 0.3680 0.0067 +/- 0.2887 VE - 6270, 6271 Sep, 1996 K-40 2.220'2 +/- 0.2730 2.0'725 +/- 0.2780 2.1464 +/- 0.1948 WW - 6.131, 6.332 Sep, 1996 H-3 16,801.228.5 +/- 999.63.39 17,111.8829+/- 1,006.0494.

16,956.5557+/- 709.119E cw -6294, 6295 Sep, 1996 Gr. Beta 4.7742+/- 1.1613 3.9486+/- 1.6377 4.3614 +/- 1.0038 cw -6294, 6295 Sep, 1996 Gr. Beta 1.0482 +/- 1.2275

-0.3383 +/- 1.~18 0.3550 +/- 0.8181 VE-6379, 6380 Sep, 1996 K...W 1.7000+/- 0.28(,()

1.8440+/- 0.1800 1.7720 +/- 0.1690 VE -6379, 6380 Sep, 1996 Sr-89

-0.0018 +/- 0.0018

-0.0009 +/- 0.0014

-0.0013 +/- o.oou VE - 6379, 6380 Sep, 1996 Sr-90 o.oou +/- 0.0006 o.<XX>S +/- o.oom 0.0008 +/- O.CXXM cw -64.12, 6433 Sep, 1996 Gr. Beta 3.1975+/- 1.5496 3.2345+/- 1.4740 3.2160+/- 1.069' VE -6481, 6482

  • Sep, 1996 Gr. Beta 2.8412 +/- 0.0780 2.8390 +/- 0.0736 2.8401 +/- O.ffi:>..

AS-10

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L" Lab Sample First Secord Averaged Codes" Date Anal2:'.sis Result Result Result VE -6481, 6482 Sep, 1996 K-40 3.3857 +/- 0.2370 3.5694 +/- 0.1540 3.4776+/- 0.1413 SW - 6524, 6525 Sep, 1996 H-3 223.5200 +/- 90.7888 151.2226+/- 87.8631 187.3714 +/- 63.1715 SWT - 6545, 6546 Sep, 1996 Gr. Beta 2.7317 +/- 0.5235 2.1160 +/- 0.4971 2.4238 +/- 0.3610 AP-7220, 7221 Sep, 1996 Co-60 0.0006 +/- 0.ooo7 O.<XX>l +/- 0.0011 0.0003 +/- O.CXXl6 AP - 7220, 7221 Sep, 1996 Cs-134

-0.0001+/-0.()006 O.<XX>l +/- 0.0007

-0.0000+/- 0.00>4 AP-7220, 7221 Sep, 1996 Cs-137

-0.0002 +/- 0.()006 0.00)9+/-0.~

0.0004 +/- 0.0005 AP - 7220, 7221 Sep, 1996 I-131(g) 0.0013 +/- 0.0041 0.00)4 +/- 0.0063 O.OOOJ +/- 0.0038 AP - 7220, 7221 Sep, 1996 I<-40 0.0193 +/- 0.0100 0.0297 +/- 0.0160 0.0245 +/- 0.0094 ow -6572, 6573 Sep, 1996. Gr. Alpha 1.0'2~+/-0.6412 0.2799 +/- 0.3100 0.6541+/-0.3561 ow -6572, 6573 Sep, 1996 Gr. Beta 2.8779 +/- 0.830'1 2.4510+/- 0.2702 2~6645 +/- 0.4368 SW - 6593, 6594 Sep, 1996 H-3 58.2259 +/- 80.0000 89.9855 +/- 81.4187 74.1057 +/- 57.08.10 cw -6616, 6617 Sep, 1996 Gr. Beta 3.1242+/- 1.6295 4.9871 +/- 1.7193 4.0556 +/- 1.1844 cw -6616, 6617 Sep, 1996 Gr. Beta 0.2660+/- 1.o617

-0.2956 +/- 1.0'299

-0.0148 +/- 0.7396 PW - 6675, 6676 Sep, 1996 H-3 21.6674 +/- 80.1010 88.4752 +/- ~.~.

55.0713 +/- 57.6950 AP-7537, 7538 Sep, 1996 Co-60 o.oom +/- o.ooo5

-0.0000 +/- 0.0007 0.0001 +/- 0.0005 AP - 7537, 7538 Sep, 1996 Cs-137 0~0002 +/- O.oool O.<XX>2 +/- 0.0007 0.0002 +/- 0.00).j VE -6654, 6655 Sep,1996 Co-60

-0.0057+/-0.0156 0.00'22 +/- 0.0147

-0.0018 +/- 0.0107 VE - 6654, 6655 Sep, 1996 Cs-137

().0128 +/- 0.0133 0.0131+/-0.0110 0.0130 +/- 0.0086 cw -6719, 6720 Sep, 1996 Gr. Beta 2.9910+/- 1.40C4 2.1008+/-1.5106 2.5459 +/- 1.0312 cw -6719, 6720 Sep, 1996 Gr. Beta

-0.3101 +/- Ul842 1.1119+/- 1.1700 0.4006 +/- 0.7976 AP -.7558, 7559 Sep, 1996 Co-60 o.oom +/- o.oooi O.<XXlS +/- 0.0007 0.0006 +/- 0.00).j.

AP - 7558, 7559 Sep, 1996 Co-<io o.oom +/- o.ooot O.<XXlS +/- 0.0007 0.0006 +/- O.<rol AP - 7558, 7559 Sep, 1996 Cs-137

-0.0001+/-0.0006 O.<XX>2 +/- 0.0007 0.0001 +/- 0.00>4 AP

-0.0001 +/- O.ooot O.<XX>2 +/- 0.0007 0.0001 +/- O.<rol WW - 6696, 6697 Sep, 1996 H-3 313.7207 +/- 98.9677 30'2.7129 +/- 98.5588 308.2168 +/- 69.8.363 LW - 7118, 7119 Sep, 1996 Gr. Alpha 0.°"8+/- 0.405.1

-0.1825 +/- 0.3885

-0.0688 +/- 0.2807 LW - 7118, 7119 Sep, 1996 Gr. Beta 2.0623 +/- 0.4378 1.58.11+/-0.5lm 1.8227 +/- 0.3647 LW-7118, 7119 Sep, 1996 H-3 89.2546+/- 81.1237 92.8011+/-81.2786 91.D279 +/- 57.4179 E-67~,6784

. Oct, 1996 Gr. Beta 0.9337 +/- O.oo.ll 0.9578 +/- 0.0317 0.9457 +/- 0.0'229 E ".' 678.3, 6784 Oct, 1996 K-40 0.8969 +/- 0.1320 -

1.1090+/-0.1530 1.0029+/- 0.1010 E-6m,6784 Oct.1996 Sr-89

-0.0002 +/- 0.0002

-0.0009 +/- 0.0029

-0.0006 +/- 0.0022 E - 6783, 6784 Oct.1996 Sr-90 o.ooa; +/- 0.0013 O.<XXlS +/- O.OOU o.~+/-o.CXX>9 SW -6877, 6818 Oct, 1996 H-3 1,223.4684+/- 119.5914 1,320.24.12 +/- 122.4059 1,271.8558 +/- 85.564~

AP* 7199, 7200 Oct, 1996 Sr-89

-0.0006 +/- 0.0015 O.<mS +/- 0.0020

-0.0001 +/- 0.0013 AP-7199, 7200 Oct, 1996 Sr-90 O.<XXM +/- O.ooo6 O.<XX>6 +/- 0.00(8 0.()(X6 +/- 0;0005 MI - 6746, 6741 Oct, 1996 1-131

-0.092.5 +/- 0.2640 0.1078 +/- 0.251' 0.0077 +/- 0.1823 MI - 6746, 6741 Oct, 1996 I<-40 1,427.9000+/- 180.oro>

1,425.3(Q) +/- 20J.<<XXX>

1,426.6000 +/- 137.53!

AS-11

Table A-5.

In-house "duplicate" samples.

Concentration in pCi /L 1

Lab Sample First Second Averaged Codesb Date Anal~sis Result Result Result p - 6824, 6825 Oct, 1996 Co-60 0.0164 +/- O.ot~

0.0030 +/- 0.0057 0.0097 +/- 0.0061 F - 6824, 6825 Oct, 1996 Cs-137 0.0087 +/- 0.()()73 0.0039 +/- 0.0051 0.006.3 +/- 0.00'4 WW - 6926, 6927 Oct, 1996 CcHiO 0.8880+/- 13900

-0.4140 +/- 2.7800 o.2370+/- 1.5541 WW - 6926, 6927 Oct, 1996 Cs-137 1.2900 +/- 1.scxx>

1.8300 +/- 3.2300 1.5(,00 +/- 1.780'7 WW - 6926, 6927 Oct, 1996 H-3 7.~1+/-78.2685.

-3.5430 +/- 77.7859 1.7715 +/- 55.1738 G -7001, 7002 Oct, 1996 Co-60 0.0072 +/- 0.()247 0.0046 +/- 0.0099 0.0059 +/- 0.0133 G -7001, 7002 Oct, 1996 Cs-134 0.0101+/-0.0188 0.0043 +/- 0.0099 0.0072 +/- 0.0106 G - 7001, 7002 Oct, 1996 Cs-137

. -0.0068 +/- 0.0204

-0.0042 +/- 0.0093

-0.0055 +/- 0.0112 G - 7001, 7002 Oct, 1996 Gr. Beta 5.2080 :t 0.2(,00 5.1980 +/- 0.2600 5.2030 :t 0.1838 G-7001,7(Xl2 Oct, 1996 1-131(g)

-0.0137 +/- 0.0072 0.0141 +/- 0.0183 0.0002 +/- 0.0207 G - 7001, 7002 Oct, 1996 K-40 6.1948 :t 0j170 5.5229 +/- 0.4170 5.8589 :t 0.4147

$ - 7024, 7025 Oct, 1996.

Cs-137 0.0141+/-0.0132 0.0248 +/- 0.. 0125 0.0195 :t 0.0091

$ - 7024, 7025 Oct, 1996 Gr. Beta 7.6523+/- 2.()292 6.4672 +/- 1.8437 7.0597+/- 1.37~

$ - 7024, 7025 Oct, 1996 K-40 7.1780 +/- 0.5510 6.9053 +/- 0.4040 7.0417+/-0.3416.

LW - 700, 7046 Oct, 1996 Co-60.

1.6200+/-3.1100

-0.7530 :t 2.9100.

0.4335 :t 2.1296 LW - 7045, 7046 Oct, 1996 Cs-134*

-0.0246 :t 3.D400

-1.9300+/-3.0500.

-0.9773 :t 2.1531 LW - 7045, 7046 Oct, 1996 Cs-137

-0.9~+/- 2.8500 1.9300+/- 2.9700 0.4735 +/- 2.(1581 LW - 7045, 7046 Oct, 1996 Gr. Beta 2.8219:t0j438 2.8922 :t 0.5347 2.8571 +/- 0.4580 LW-7045, 7046 Oct, 1996 1-131 0.2410 +/- 0.3690

-0.2043 +/- 0.641 0.0184 :t 0.2926.

LW -7045, 7046 Oct, 1996 I-131(g)

.,.1500+/- 29.9(0) 5.8000+/- 27.7000 0.3250 +/- 20.3795 LW-7045, 7046 Oct, 1996 K-40 51.3000 :t 37.9(0) 34.S(XX) t 33.8000 42.9(XX) :t 25.3912 F -6952, 6953 Oct, 1996 K-40 2.7927 +/- 0.1670 2.7243 t 0.1020 2.7585 :t 0.0978 MI-6853,6854 Oct, 1996

~

-0.7610 t 4.7900 1.8000+/- 2.8100 0.5195 t 2.7767.

MI-6853,6854.

Oct, 1996 Cs-137 1.5500+/- 3.5900

-0.8890 :t 2.4000 O.Jaa; :t 2.1592 Ml -6853, 6854 Oct, 1996 1-131

-0.1067+/-0.27~

0.20'27 :t 0.2586 0.0490 :t 0.1886.

MI -6854, 6855 Oct, 1996 Co-60 1.8000+/- 2.8100 0.4.510+/- 4.9000 1.1255+/- 2.8243 MI -6854, 6855 Oct, 1996 Co-60 1.8000+/- 2.8100 0.4510+/-4.9000 1.1255+/- 2.8243 MI -68.54, 6855 Oct, 1996 Cs-137

-0.8890 :t 2.4'XX>

1.5900+/- 3.2700 0.35Q5 :t 2.0281 Ml_.;. 6854, 6855 Oct, 1996. Cs-137

-0.8890+/- 2.4'XX>

1.5900+/- 3.2700

. 0.35Q5 :t 2.0281 Ml - 68.54, 6855 Oct, 1996 1-131 0.0490+/- 0.1886

-0.1840+/- 0.2910

-0.0675 +/- 0.1'34 MI - 68.54, 6855 Oct, 1996 1-131 0.2000 +/- 0.2(,00

-0.1837 t 0.2904 o.cxm+/-o.1949 Ml -6854, 6855 Oct, 1996 1-131 0.2027 +/- 0.2586

-0.1840 +/- 0.2910 0.0094 :t 0.1946 BS - 7138, 7139 Oct, 1996 Gr. Beta 9.5648+/- 2.4583 7.9345 :t 2.3466 8.7497+/- 1.6993 BS - 7138, 7139 Oct, 1996 K-W 7.2366 +/- 0.4000 7.1729 :t 0.5230 7.20C8 +/- 0.3.101 so -7306, '1'J(J1 Oct, 1996 Cs-137 0.2375 :t 0.()2.5()

0.2243 :t 0.007

. 0.2309 :t 0.0252 so -7306, '1'J(J1 Oct, 1996 K-40 9.4591+/-0.4680 9.4848 +/- 0.1300 9.4720+/-0.~

BO - 7747, 7748 Oct, 1996 Gr. Beta 1.6819+/- 0.3193 1."542 +/- 0.3010 1.5681 :t 0.221!.

AS-12

Table A-5.

In-house "duplicate" samples.

Concentration in pCi/L 1

Lab Sample First Second Averaged Codesb Date Anal~sis Result Result Result BO - 7747, 7748 Oct.1996 K-40 0.7271+/-0.1770 0.5964+/-0.1430 0.6617 +/- 0.1138 F - 7328, 7329 Oct. 1996 K-40 2.0975 +/- 0.4500 1.7161+/-0.38.50 1.9068+/- 0.2961 Ml - 728.5, i286 Oct.1996 1-131

-0.1241+/-0.2~

-0.056.5 +/- 0.2463

-0.0903+/- 0.1721 cw -7176, 7177 Oct, 1996 Gr. Beta 3.1350+/- 1.()492 2.2278 +/- 0.9950 2.6814 +/- 0.72:30 MI - 7351, 7352 Oct, 1996 Sr-89

-0.4959+/- 13277

-2.6954+/-1.1984

-1.5956+/- 0.8943 MI - 7351, 7352 Oct, 1996 Sr-90 1.6216+/-0.4003 1.5659 +/- 0.3840 1.5938 +/- 0.2774 VE - 7425, 7426 Oct, 1996 K-40 1.92CB +/- 0.2360 1.7284 +/- 0.2700 1.8244+/- 0.1793 MI - 7514, 7515 Oct, 1996 Co-60 2.1800+/- 5.t<XX>

5.8600 +/- 5.3900 4.0200 +/- 3.7102 MI - 7514, 7515 Oct, 1996 Co-60 2.1800 +/- 5.1<XX>

5.8600 +/- 5.3900 4.0200 +/- 3.7102 MI - ~14, 7515 Oct, 1996 Cs-137 0.2630 +/- 3.4<XX>

1.3400 +/- 4.3000 0.8015 +/- 2.7409 MI - 7514, 7515 Oct, 1996 Cs-137 0.2630 +/- 3.4<XX>

1.3400 +/- 4.3000 0.8015 +/- 2.7409 MI - 7514, 7515 Oct, 1996 1-131

-0.0367 f 0.2747 0.0170 +/- 0.2780

-0.0098+/- 0.1954 F - 7584, 7585 Oct, 1996 Co-60 0.0051 +/- 0.0115 0.0050 +/- 0.0119 0.0051 +/- O.<ml F - 7584, 7585 Oct, 1996. Cs-137 0.0048+/-0~7 O.CXX>6 +/- 0.0094 0.0027 +/- 0.0064 WW - 7653, 7654 Oct, 1996 Co-60 0.5440 +/- 1.7200

-3.0500 +/- 2.8000

-1.2530 +/- 1.6430 WW - 7653, 7654 Oct, 1996 Co-60 0.5440 +/- 1.7200

-3.0500 +/- 2.8000

-1.2530 +/- 1.6430 WW - 7653, 7654 Oct, 1996 Cs-137

-0.3090 +/- 1.9800

-1.3700 +/- 3.5700

-0.8395 +/- 2.0412 WW - 7653, 7654 Oct, 1996 Cs-137

-0.3090+/- 1.9800

-1.3700 +/- 3.5700

-0.8395 +/- 2.0412 WW - 7653, 7654 Oct, 1996 H-3

-20.6120+/- 75.8854 27.0900 +/- 78.0749 3.2390 +/- 54.4387 ss -S(M(), son Oct, 1996 1(-4()

222090 +/- 0.8210 23.4780 +/- 0.8550 22.8435 +/- 0.5927 swr -7972, 7973 Oct, 1996 Gr. Beta 2.7320 +/- O.sm9 2.13.53 +/- 0.5134 2.4337 +/- 0.3604 cw -7794, 7795 Ckt, 1996 Gr. Beta 1.2200+/- lj(XX) 2.3526 +/- 1.7822 1.7863+/- 1.2315 ow -7994, 7995 Oct, 1996 Gr. Beta 1.6467 +/- 0.4826 1.83.57 +/- 0.4.589 1.7412+/- 0.3330 ow -7994, 7995 Oct, 1996 H-3 6Ul848 +/- 81.6689 29.6241+/-80.1237 46.8545 +/- 57.2049 WW - 8121, 8122 Nov, 1996 Gr. Beta 5.2418 +/- 0j885 4.8908 +/- 0.7351 5.0663 +/- 0.5390 WW - 8121, 8122 Nov, 1996 H-3 49.1914 +/- 783272 25.7955 +/- 77.2446 37.4935 +/- 55.0042 cw -8089, 8090 Nov, 1996 Gr. Beta 2.0590+/- lj640

-0.0624 +/- 1.6065 0.998.3 +/- 1.1930 cw -8089, 8090 Nov, 1996 Gr. Beta

-0.3253 +/- 1.5458 0.0096 +/- 1.5731

-0.1479+/- 1.1027 swu -8213, 8214 Nov, 1996.Gr. Beta 2.5755 +/- 0.5930 1.9537 +/- 0.5962 2.2646 +/- 0.4204

. swu -8213, 8214 Nov, 1996 ii-3 257.8646 +/- 86.6697 234.9041+/-85.7288 246.3843 +/- 60.9~

swu -8213, 8214 Nov, 1996 1(-40 109.2500+/-41.2(0) 97.1440+/- 52.(XX)()

1m.197o+/- 33;1111 cw -830'2, 8300 Nov, 1996 Gr. Beta 0.9444+/- 1.4135 2.1017 +/- 1.4184 1.5230 +/- 1.0012 Ml - 8337, 8.138 Nov, 1996 1-131

. -0.0286 +/- 0.2146 0.0724 +/- 0.2406 0.0219 +/- 0.1612 Ml - 8331, 8.138 Nov, 1996 K-40 1,454.6000+/- 91.6CXX>

1,36.5.5000 +/- 193.<XXX) 1,410.0500 +/- 106.8171 WW - 8.561, 8562 Nov, 1996 H-3 4,719.0000 +/- 197.()00) 4,718.8173 +/- 197.2068 4,718.9387 +/- 139.3732 SW - 8581, 8582 Nov, 1996 Gr. Beta 3.1780+/- 0.6522 2.4547 +/- 0.6458 2.8164 +/- 0.4589 WW - 8681, 8682 Nov, 1996 Gr. Alpha 0.1083+/-.1.7623

-1.6686+/-1~

-0.7802 +/- 1.1697 AS-13

Table A-5.

In-house "duplicate" samples.

Concentration in pCJ/L*

Lab Sample First Second Averaged Codesb Date Anal;t'.!iS Result Result Result WW - 8681, 8682 Nov, 1996 Gr. Beta 2.7636+/- 1.6718 1.2914 +/- 1.6711 2.0275 +/- 1.1819 cw -8612, 8613 Nov, 1996 Gr. Beta 2.5959+/- 1.4986 1.9085 +/- 1.4277 2.2522 +/- 1.()349 cw -8612, 8613 Nov, 1996 Gr. Beta 0.0730+/- 1.()631

-0.7679 +/- Ul588

-0.3474 +/- 0.7502 cw -9219, 9220

.Nov, 1996 Co-(,()

0.4990+/- 1.9100

-0.2780 +/- 1.6600 O.lla5 +/- 1.26.53 CW-9219, 9220 Nov, 1996 Cs-137 1.3800+/- 2.0100 0.1520 +/- 1.6300 0.7660 +/- 1.2939 cw -9219, 9220 Nov, 1~

H-3 2,091.6585 +/- 147.()922 2,206.2783 +/- 149.9008 2,148.9684 +/- la5.0076 cw~ 8830, 8831 Nov, 1996 Gr. Alpha 0.1864 +/- 0.30t4 0.4130 +/- 0.3037 0.2997 +/- 0.2150 cw -8830, 8831 Nov, 1996 Gr. Beta 11.0713 +/- 0.6482 10.214i +/- 0.5784 10.6457 +/- 0.4344 cw -8830, 8831 Nov, 1996 H-3 2,a53.4722 +/- 144.()356 2, 112.1937 +/- 145.4793 2,082.8329 +/- 102.36o:r cw -8830, 8831 Nov, 1996 Sr-89

-0.2648 +/- 0..53.lS

-0.2665 +/- 0.6325

-0.2656+/- 0.4137 cw -8830, 8831 Nov, 1996 Sr-90 0.2880 +/- 0.3295 0.2980 +/- 0.390.5 0.2930 +/- 0.2555 SW-~,8636 Dec, 1996 Gr. Beta 2.4968 +/- 0.8007 3.0769 +/- 0.1191 2.7869 +/- 0.5.599 SW-~,8636 Dec, 1996 K-40 90.1230 +/- 52.800) 90.4480 +/- 51.9000 90.2855 +/- 37.0184 ow -8660, 8661 Dec, 1996 Gr. Beta 2.1325 +/- 0.5706 1.8680+/- 0.5881 2.<Xm +/- 0.4097 ow -8660, 8661 Dec, 1996 H-3 110.()746 +/- 83.6820 li7.3323 +/- 8.1.9962 113.700.5 +/- 59.2833.

Ml - 8704, 87

  • 1,342.9(XX) +/- 150.<XXXJ 1~22.QSOO +/- 102.~' Ml - 8725, 81'26 Dec, 1996 Co-(,() 0.4980+/- 2j500 0.40W +/- 4.4400 0.4530 +/- 2;611;, .MI-8725, 81'26 Dec, 1996 Cs-134 1.2300+/- 23300 -0.6'50 +/- 3.8000 0.2925 +/- 2.2287 Ml - 8725, 8726 Dec, 1996 .Cs-137 1.7600+/- 2.5400 1.1100 +/- 3.3900 1.43.50 +/- 2.1180 Ml - 8725, 8726 Dec, 1996 1-131 -0.1756+/- 0.1896 -0.1739 +/- 0.2108 -0.1747+/- 0.1418 Ml - 8725, 8726 Dec, 1996 l-131(g) -0.9720+/- 3.4<XX) 4.5100 +/- 4.8700 1.7690+/- 2.9697 Ml - 8725, 8726 Dec, 1996 K-40. 1,402.2000+/- 111.DOO> . 1,297.S<XXJ +/- 150.<XXXJ 1,349.&500+/- 93.3019 Ml - 8725, 8726 Dec, 1996 Sr-89 -1.0624 +/- 1.()291 -1.0463+/- 1.0044 -1.0543 +/- 0.7190 Ml - 8725, 8726 Dec, 1996 Sr-90 1~+/-0.3709 1.1232 +/- 0.362.5 1.2210+/- 0.2593 so -8802, 8803 Dec, 1996 Cs-137 0.4670 +/- O.o419 0.4.514 +/- 0.0074 0.4592 +/- 0.0281 so -8802, 8803 Dec, 1996 Gr. Alpha 14.o253 +/- 4.2670 13.8640 +/- 4.0'228 13.9447 +/- 2.9322 so -8802, 8803 Dec, 1996 Gr. Beta 21.4113+/-3.1354 21.4610 +/- 2.8794 21A.391 +/- 2.1285 so -8802, 8803 -Dec, 1996 K-40 11Jm90+/- 0.6660 10.8000 +/- 0.6130 10.94li0+/- 0.4518 swu -9540, 9541 Dec, 1996 Gr. Beta 7.520& +/- 0.8116 5.9562 +/- 0.8260 6.7383 +/- 0.6026 swu -9540, 9541 Dec, 1996 H-3 90.1991+/-86j(l;3 86.5424 +/- 86.5.510 88.3707 +/- 61.2554 p - 9040, 9041 Dec, 1996 Co-(,() -0.0006+/- 0.014' -0.000'2 +/- 0.0150 -0.0004 +/- 0.010& p - 9040, 90'1 Dec, 1996 Cs-134 -0.0015 +/- 0.0100 0.(0)5 +/- 0.0120 -0.cms +/- o.00'9 p - 90CO, 9041 Dec, 1996 Cs-137 0.0071+/-0.0163 0.008 +/- 0.0186 0.0&00 +/- 0.0124 p - 9040, 90tl Dec, 1996 Gr. Beta 3.5649 +/- O.D939 3.5230 +/- 0.0939 3.5440 +/- 0.0664 p - 90CO, 9041 Dec, 1996 1-131(g) O.CXOI +/- 0.0151 -0.000& +/- 0.0153 O.<Xm +/- 0.010"' p -90CO, 9041 Dec, 1996 K-40 3.2987 +/- 0.4720 3.0073 +/- 0."330 3.1530+/- 0.320.. Table A-5. In-house "duplicate" samples. Concentration in pCi/L
    • Lab Sample first Second Averaged C.odli!!l Date Anal2'.sis Result Result Result cw -9109, 9110 Dec, 1996 Gr. Beta 4.1495 +/- 1.226.5 1.9601 +/- 1.5457 3.0548 +/- 0.9866 cw -9109, 9110 Dec, 1996 Gr. Beta
    -0.8681+/-13230 -1.1056 +/- 1.3024 -0.9869 +/- 0.9282 MI - 9197, 9198 Dec, 1996 1-131 0.0738 +/- 0.3589 -0.1464 +/- 0..38(M -0.036.3 +/- 0.2615 MI - 9197, 9198 Dec~ 1996 K-40 1,462.6000+/- 143.00X> 1,381.2<XXJ +/- 149.CXXJO 1,421.9000+/- 100.2594 WW - 9269, 9270 Dec, 1996 Co..(i() -1.1100+/- 2.3300 -0.2890 +/- 2.6000 -0.6995+/- 1.7456 WW - 9269, 9270 Dec, 1996 Cs-137 -1.2100+/- 2.2100 0.2210 +/- 2.5500 -0.4945 +/- t.68n WW - 9269, 9270 Dec, 1996 H-3 1,051.0538 +/- 116j594 1, 126.1290 +/- 119.0359 ' 1,088.5914 +/- 83.3701 LW - 9291, 9292 Dec, 1996 Co..(i() -0.2250 +/- 2.()(XX) 1.2400 +/- 2.3400 0.5075 +/- 1.5391 LW - 9291, 9292 Dec, 1996 Cs-137 4.0400 +/- 2.1800 0.1930+/- 2.8300 2.116.5 +/- 1.7861 LW - 9291, 9292 Dec, 1996 Gr. Beta 4.8680+/- 1.34()1} 7.34.32 +/- 1.4448 6.1056+/- o.. 98.56 SW - 9743, 9744 Dec, 1996 H-3 1.2426+/- 89j614 51.5686+/- 91.8276 26.4056 +/- 64.2056 - SW - 9414, 9415 Dec, 1996 Gr. Beta 3.9527 +/- 0.6~ 4.6.396 +/- 0.7606 4.2961+/-0.5150 ow -9520, 9521 Dec, 1996 Gr. Beta 6.1588+/- 13500 5.6935+/- 1.2445 5.9261+/-0.9180 ow -9520, 9521 Dec, 1996 1-131 0.3470 +/- 0.4182 0.23.39 +/- 0.4184 0.2905 +/- 0.2958 cw -9383, - nee, 1996 Gr. Beta 4.7813 +/- lj392. 4.5942 +/- 1.5609 4.6877+/- 1.1685 cw -9383, 9384 Dec, 1996 Gr. Beta 0.6113 +/- 1.4866 0.4.335+/- 1.4715 0.5224+/- 1.0459 SW-9433,KW . Dec, 1996 H-3 309.2956 +/- 91.1018 241.ono +/- 88.6407 278.1883 +/- 6.3.5545 SW -9497, 9498 Dec, 1996 H-3 241.()07()+/- 91.8990 126.5590 +/- 87.2570 183.7830 +/- 6.3.3625 ow -9564, 9565 Dec, 1996 Gr. Beta 2.0290 +/- 0.5925 2.1508 +/- 0.57 49 2.0899 +/- 0.4128 ow -9564, 9565 Dec, 1996 H-3 120.7999+/- 83.3742 94.1528 +/- 82.2309 107.476.3 +/- 58.5516.
    • All concentrations are reported in pCi/liter, except solid samples, which are reported in pCi/gram.
    b Lab codes are comprised of the sample media and the sample numbers. Oient codes have been eliminated to protect client anonymity. AS-15 Table A~. Department of Energy's Mixed Analyie Performance Evaluation Program (MAPEP), comparison of MAPEP and Teledyne's Midwest Laboratory results £or various sample media*.. Concentration in Bq/lcgb lab Sample Date Teledyne Results MAPEi' Result' Control Code Type Collected Analysis +/-Standard Deviationc ls, N=l Limits STS0-776 SOIL Sep, 1996 Am-2'1. 27.0 28.7 +/- 2.8 20.9
    • 37.3 Standard deviation for three determinations not reported in MJxed Analyte Performance Evaluation Program Summary Report.
    STS0-716 SOIL Sep, 1996 ~ 879.0 812.0+/-83.S 568.4. 1,055.6 Standard deviation for three determinations not reported in MJxed Analyte Performance Evaluation Program* Summary Report. STS0-776 SOIL Sep, 1996 Cs-137 1,716.0 l,531;0+/- 193.4 1,071.7 - 1,990.3 Standard deviation for three determinations not reported in Mixed Analyie Performance Evaluation Program Summary Report. ' STS0-776 SOIL Sep, 1996 Pu-238 13.0 15.9+/- 1.8 11.1
    • 20.7 Standard deviation for three determinations not reported in Mixed Analyte Performance Evaluation Program Summary Report.
    STS0-776 SOIL Sep, 1996 Pu-239 /240 18.0 19.7 +/- 2.0 13.8
    • 25.6 Standard deviation for three determinations not reported in Mixed Analyte Performance Evaluation Program Summary RepOrt.
    STS0-776 SOIL Sep, 1996
    • Sr-90 441.0 536.0+/- 57.l 375.2
    • 696.8 Standard deviation for three determinations not reported in Mixed Analyte Performance Evaluation Program Swnma.ry Report.
    STS0-116 SOIL. Sep, 1996 U-234/233
    • 59.0 63.9+/- 7.3 44.7
    • 83.1 Standard deviatlOn for three determinations not reported bt Mixed Analyte Performance Evaluation Program Summary Report.
    STS0-776 SOIL Sep, 1~ U-238 fiO.O 64.0+/-6.4 44.8-83.2 Standard deviation *for three detafttinations not reported in Mixed Ana1yte Performance Evaluation Program Swnma.ry Report..
    • Results obtained by Teledyne Brown F.ngineering Environmental Servia!S Midwest Laboratory as a participant in the Department of F.nergy's Mixed Analyte Perfonnance Evaluation Program, Idaho Operations ~
    Idaho Palls, Idaho. " All results are in Becquerels per kilogram as requested by the Department of f.nergy. c UnJeu otherwise indJca~ the TBEESML results are given as the mean +/- l standard deviations for three determinations.
    • MAPEP results are presented u the known values and expet1l!d laboratory precision (ls, 1 determination) and control limits u defined by the MAPEP.
    A6-1 Table A-7. Environmental Measurements Laboratory Quality Assessment Program (EML), romparison of EML and Teledyne's Midwest Laboratory results for various sample media*. Concentration in Bq/L*1b Lab Sample Date Control Code Type Collected Analysis *' Teledyne Resultc
    • EML Resultd Limits' STW-755 WATER Mar, 1996 Am-241 0.8+/-0.1 0.8+/-0.0 0.7 ~ 1.6 STW-755 WATER Mar, 1996 OHiO 33.6+/- 1.0 32.8+/-0.6 0.9 - 1.2 STW-755 WATER Mar, 1996 Cs-137 42.8+/- 1.3 38.3+/-0.9 0.9 - 1.3 STW-755 WATER Mar, 1996 Fe-55 109.0+/-21.7 83.0+/-3.4 0.3 - 1.6 STW-755 WATER Mar,1996 H-3 434.0+/-34.1 251.0t 11.4 0.1-1.9 STW-755 WATER Mar,1996 Mn-54 41.9+/- 1.4 38.4+/- 1.2 0.9 - 1.2 STW-755 WATER Mar,1996 Pu-238 0.9+/-0.1 1.0+/-0.1 0.1-1.3 STW-755 WATER Mar, 1996 Pu-239 0.7+/-0.1 0.8+/-0.1 0.6. 1.4 STW-755 WATER Mar,1996 Sr-90 2.2+/-0.7 1.5+/-0.0 0.1-1.7 STW-756 WATER Mar,1996 Gr. Alpha 2,180.0+/- 53.S 1,850.0t 185.0 0.6. 1.3 STW-756 WATER Mar,1996 Gr. Beta 872.0+/-27.0 744.0+/-74.0
    .0.8. 1.7 STS0-757 SOIL Mar, 1996 Am-241 6.2+/- 2.9 3.7+/-0.5 0.5. 2.4 STS0-757 SOIL Mar, 1996 Cs-137 404.0+/-0.2 359.0+/- 10.0 0.1. 1.4 STS0-751 SOIL ~ar, 1996 K-40 525.0+/-23.3 46.5.0+/- 30.0 0.1-1.6 STS0-757 SOIL Mar, 1996 Pu-238 42.3+/- 1.6 43.0+/-2.4 0.2
    • 2.0 STS0-757 SOIL Mar,1996 Pu-239 9;0+/-0.7 9.2+/-0.3 0.6-2.0 STS0-757 SOIL Mar,1996 Sr-90 1,200.0 t 32.3 1,340.0+/- 113.0 0.6
    • 3.0 STS0-757 SOIL Mar, 1996 Uranium 68.2+/-2.4 71j+/-4.2 0.3. 1.5 S'IVE-758 VEGETATION Mar, 1996 Am-241 6.1+/-1.3 5.6+/-0.2 0.6. 2.9 S'IVE-758 VEGETATION Mar, 1996 Cm-244 6.0+/- 1.2 4.4+/-0.2 0.4. 1.9 S'IVE-758 VEGETATION Mar, 1996 OHiO 65.6+/-4.0 59.7+/- 1.0 0.6. 1.5 S'IVE-758 VEGETATION Mar, 1996 Cs-137 1,100.0t 12.6 944.0+/-16.2 0.8. 1.5 S'IVE-758 VEGETATION Mar, 1996 K-40 1,190.0+/-61.6 1,000.0t 33.0 0.5. 1.5 S'IVE-758 VEGETATION Mar, 1996 Pu-239 9.2+/- 1.3 9.8+/- 1.2 0.6-2.0 S'IVE-758 VEGETATION Mar, 1996 Sr-90 1,210.0t 32.2
    . 1,300.0+/- 52.4 0.5. 1.4 STAP-759 AIR FILTER Mar,1996 Am-241 0.3+/-0.0 0.2+/-0.0 0.6. 1.9 STAP-759 AIR FILTER Mar, 1996 Ce-144 23.2+/- 1.0 33.3+/-3.3 0.6-1.3 STAP-759 AIR FILTER Mar, 1996 Co-57 6.1+/-0.1 8.9+/-0.9 0.6-1.3 STAP-759 AIR FILTER Mar, 1996 ~ 26.5+/-0.4 29.5+/-2.9 0.1-1.3 STAP-759 AIR FILTER Mar, 1996 Cs-134 12.9+/-0.3 14j:t: 1.5 0.7 - 1.2 STAP-759 AIR FILTER
    • Mar, 1996 Cs-137 6.2+/-0.9 6.6+/-0.1 0.1-1.3 STAP-759 AIR PILTER Mar, 1996 Mn-54 3.3+/-0.4 3.4+/-0.4 0.8 - 1.3 STAP-759 AIR FILTER Mar, 1996 Pu-238 0.1+/-0.0 0.1+/-0.0 0.6-1.6 STAP-759 AIR FILTER Mar, 1996 Pu-239 0.1+/-0.0 0.1+/-0.0 0.7-1.6 STAP-759 AIR FILTER Mar, 1996 Ru-106 10.2+/- 1.9 11.6+/- 1.4 0.5 - 1.6 STAP-759 AIR PILTER Mar, 1996 Sb-12.5 10.1+/-0.8 9.8+/- 1.0 0.4-1.4 STAP-759 AIR FILTER Mar, 1996 Sr-90 1.1+/-0.2 1.i+/-O.O 0.6. 2.3 STAP-759 AIR PILTER Mar, 1996 Uranium 0.1+/-0.0 0.1+/-0.0 0.8 - 2.9 A1*1
    Table A-7. Environmental Measurements l.Aboratory Quality Assessment Program (EML), comparison of EML and Teledyne's Midwest Llboratory results for various sample media*. Lab Code Sample Type Concentration in Bq/L*1b Date Collected Analysis Teledyne Resultc EML Result4 Control Limits' STAF-760 AIR FILTER Mar, 1996 Gr. Alpha 2.2+/-0.1. 1.6+/-0.2 0.8-1.6 STAF-760 AIR FILTER Mar, 1996 Gr. Beta 2.0+/-0.0 1.8+/-0.2 0.8-1.9 STW-710 WATER Sep,1996 Am-241 1.3+/-0.2 1.1+/-0.0 0.6-1.7 STW-710 WATER Sep, 1996 Co-60 65.0+/-2.2 61.1+/-0.7 0.9 - 1.2 STW-710 WATER Sep,1996 Cs-137 96.1+/-3.0 89.5+/-1.4 0.9-1.3 STW-710 WATER Sep, 1996 Gr. Alpha 993.0+/- 12.2 1,210.0+/- 121.0 0.5 - 1.3 STW-710 WATER Sep, 1996 Gr. Beta 579.0+/-8.J 540.0+/-54.0 0.6-1.6 STW-710 WATER Sep, 1996 H-3 488.0+/-34.6 587.0+/-58.0 0.7-1.9 STW-770 WATER Sep, 1996 Mn-Sf 65.0+/-3.0 60.5+/-0.6 0.9-1.2 STW-770 WATER Sep, 1996 Pu-238
    • 1.3+/-0.3 1.9+/-0.1 0.7-1.3 An investigation was conducted. No errors in calculations or transcription were noted. "The analysis was repeated in duplicate under the observation of the Technical Lead. No descrepancies were noted in the performance of the procedure. The result of the reanalysis was 2.14+/-0.11 Bq/L. No further action is planned.
    STW-770 WATER Sep, 1996 Pu-239 . 0.7+/-0.2 0.8+/-0.0 0.8-1.4 SlW-770 WATER Sep, 1996 Sr-90 3.6+/-0.7 2.7+/-0.2 0.7-1.7 SlW-770 WATER Sep, 1996 U-234 0.5+/-0.2 0.5+/-0.0 0.8 - 1.5 SlW-770 WATER Sep, 1996 U-238 0.4+/-0.1 0.5+/-0.4 0.8-1.4 STS0-771 SOIL Sep, 1996 Am-241 15.6 +/- 3.8 13.S +/- 0.5 0.5 - 2.7 STS0-771 SOIL Sep, 1996 Co-60 4.0+/-2.5 2.9+/-0.2 0.5-1.5 STS0-771 SOIL Sep, 1996 Cs-137 1,750.0+/- 24.4 1,550.0+/- 22.2 0.8-1.3
    • STS0-771 SOIL Sep, 1996 K-40 369.0+/-59.S 300.0+/-25.0 0.7-1.7 STS0-771 SOIL Sep, 1996 Pu-238 0.8+/-0.4 1.1+/-0.2 0.4-1.9 STS0-771 SOIL Sep, 1996 Pu-239 24.0+/- 1.9 21.8+/- 1.1 0.7-1.9 STS0-771 SOIL Sep, 1996 Sr-90 6.3.6+/-4.0 69.9+/-5.1 0.5-2.8 STS0-771 SOIL Sep, 1996 U-234 37.2 +/- 3.8 39.2 :t 2.4 0.4 - 1.3 STS0-771 SOIL Sep, 1996 U-238 40.8+/-4.0 41.6+/-0.6 0.4 - 1.6 S1VE-772 VEGETATION Sep, 1996 Am-241 1.5+/-0.9 1.2+/-0.4 0.7-2.8 S1VE-772 VEGETATION Sep, 1996 Cm-244 0.6 +/- 0.5 0.8 +/- 0.1 0.5 - 1.7 S1VE-772 VEGETATION Sep,1996 Co-60
    • 14.0+/-4.4 10.9+/-0.7 0.6-1.4 S1VE-772 VEGETATION Sep, 1996 Cs-137 219.0+/- 10.1 190.0+/-6.7 0.8-1.5 S1VE-772 VEGETATION Sep, 1996 K-40 1,160.0+/-99.4 992.0+/-29.0 0.8-1.S S1VE-772 VEGETATION Sep, 1996 Sr-90 1,420.0+/-35.1 1,390.0+/- 12.0 0.5-1.3 STAP-773.
    AIR FILTER Sep, 1996 Co-57 11.8+/-0.3 14.8+/-0.8 0.6-1.2 STAP-773 AIR FILTER Sep, 1996 Co-60 9.2+/-0.4 8.6+/-0.4 0.7-1.2 STAP-773 AIR FILTER Sep, 1996 Cs-134 9.6+/-0.4 10.8+/-0.4 0.7-1.2. STAP-773 AIR FILTER Sep, 1996 Cs-137 8.7+/-0.4 8.5+/-0.4 0.7-1.3 STAP-773 AIR FILTER Sep, 1996 Gr. Alpha 0.7+/-0.0 1.2+/-0.1 0.8-1.6. An investigation was conducted and a transcription error while calculating the result was discovered. The recalculated value is 1.15+/-0.0lBq/filter. No further action ls planned. A7-2 Table A-7. Environmental Measurements Llboratory Qualify Asse>>ment Program (EML), comparison of EML and Teledyne's Midwest Llboratory results for various sample media*. Concentration in Bq/L"1" Lab Sample Date Code Type Collected Analysis Teledyne Resultc EML Result4 STAP-713 AIR FILTER Sep, 1996 Gr. Beta 0.5+/-0.0 0.5+/-0.1 STAP-773 AIR FILTER Sep, 1996 Mn-54 7.1 +/- o.s 6.4+/-03 STAP-713 AIR FILTER Sep,1996 Ru-106 11.5+/- 3.2 10.8+/- 1.1 STAP-773 AIR FILTER Sep, 1996 Sb-125 12.4+/- 1.0 10.8+/-0.5 Control Limits' 0.7 - 1.8 0.8 - L.3 0.6-13 0.6 - 1.4
    • The Environmental Measurements Laboratory provides the following nuclear species: Air Filters, Soil, TtSsue, Vegetation and Water. Teledyne does not participate in the T1Ssue program.
    "Results are reported in Bq/L *1 with the following exceptions: Air Filter results are reported in Bq/Filter*1, Soil results are reported in Bq/Kg*1, Vegetation resUlts are reported in Bq/Kg*1* 'The results of elemental Uranium are reported in ug/filter'1, g, or ml. c Teledyne results are reported as the mean of three determinations+/-standard deviation. 4 The EML result listed is the mean of replicate determinations for each nuclide:t:the standard error of the mean.
    • The *control limits are reported by EML and are established from percentiles of historic data distributions (1982-1992). 'The evaluation of this historic data and the development of the control limits is presented in OOE report EML-564.
    A7-3 ENCLOSURE F CONSUMERS ENERGY COMPANY PALISADES PLANT DOCKET 50-255 PALISADES NUCLEAR PLANT 1996 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT DATA GRAPHS 25 Pages 1996 PALISADES PARTICULATE Weekly Gross Beta Grand Rapids-Control vs Tower Hill, H Soderberg, J Sarno 0.060 0.055 0.050 0.045 0.040 CY') 0.035 E ~ 0.030 0.025 0.020 0.015 0.010 0.005 I Jan I Feb I Mar I Apr I May I Jun I Jul I Aug I Sep I Oct I Nov I Dec I Tower Hill 5 SSE H. Soderberg 5 SE J Sarno 3.5 ESE G.R.-C 55 NNE 0.060 0.055 0.050 0.045 0.040 ('I) 0.035 E ~ 0.030 0.025 0.020 0.015 0.010 0.005 1996 PALISADES. PARTICULATE Weekly Gross Beta Kalamazoo-Control vs Township Park, State Park I Jan I Feb I Mar I Apr I May I Jun I Jul I Aug I Sep I Oct I Nov I Dec I State Park 1 N Township Park 1.5 S Kalamazoo-C 35 E 1996 PALISADES PARTICULATE Weekly Gross Beta Dowagiac-Control vs Sherman Dairy, R Bus, P Rood 0.065 ----r-----------------------------, 0.060 0.055 0.050 0.045 (") 0.040 E
    -:::: 0. 035
    (.) c.. 0.030 0.025 0.020 0.015 0.010 0.005
    ~

    I Jan I Feb I Mar I Apr !May I Jun I Jul !Aug I Sep I Oct I Nov I Dec I P Rood 3 E R Bus 4.75 NE Sh Dairy 7.5 NNE Dowagiac-C 39 SSE

    0.10 0.09 0.08 0.07 0.06 M

    E 0.05

    (.) c.

    0.04 0.03 0.02 0.01 0.00 1968-1969 1991 Palisades articulate Gross Beta Pre-Operational vs. Operational 1992 1993 1994 1995 Pre-operational Kalamazoo Site Kalamazoo Trend Site Trend 1996

    Palisades Lake ter Gross Beta 1991 -1996 4.0 3.5 3.0 2.5 Q)

    2.0 u
    0.

    1.5 1.0 0.5 0.0 1991 1992 1993 1994 1996 Intake Discharge S. Haven Raw S. Haven Treated

    ,~,//*'

    -~ I

    ~

    Intake Trend Discharge Trend Raw Trend Treated Trend

    1996 Palisades L Water Samples Gross Beta pCi/L Ludington Control vs Intake, South Haven Treated & Raw 8.0 7.0 6.0 5.0

    ...J

    4 0

    (.)

    Q.

    3.0 2.0 1.0 0.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Intake South Haven Treated South Haven Raw Ludington

    Palisades Well ter Gross Beta Pre-Operational vs. Operational 6.0

    -,--------------------------~

    5.0

    ~

    ~

    ~

    4.0

    ~

    ~

    L...

    (I)

    +-I

    -- 3.0

    ()

    0.

    2.0

    ~

    ~

    ~

    1.0

    ~

    ~

    ~

    ~

    0.0

    ~

    1968-1969 1991 1993 1996 Pre-Operational Township Park Site State Park Township Park Trend Site Trend State Park Trend

    12.0 11.0 10.0 9.0 8.0 7.0

    ...J 6.0

    (.) c.

    5.0 4.0 3.0 2.0 1.0 0.0 1996 Palisades Water Samples Gross Beta pCi/L Ludington Control vs Warehouse, Well #14, Well#15 and Well #16 132.a 1 Jan Feb Mar Apr May Warehouse

    1. 14 Jun Jul
    1. 15 Aug
    1. 16

    ~I~

    Sep Oct Nov Dec Ludington

    7.0 6.0 5.0

    -' 4.0 0

    Q. 3.0 2.0 1.0 0.0 1996 Palisades 'J'9 Water Samples Gross Beta pCi/L Ludington Control vs Site, Outage Building, State Park and Township Park

    • Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Site State Park Township Park Outage Building Ludington

    >K

    Palisades Quarterly Ther luminescent Dosimeters

    • 1991 - 1996 18 16 14 03 12 t ro 5-10 E

    Q) 8 E

    6 4

    2 1991 1992 1993 1994 1995 1996 Inner Ring Outer Ring Control Inner Trend Outer Trend Control Trend

    ~

    II

    '/;~ 1

    I...

    co Q) 70 60 50

    ~ 40

    ~

    E 30 20 10 0

    Palisades Annual Ther.

    minescent Dosimeters 1991 - 1996 1991 1992 1993 1994 1995 1996 Inner Ring Outer Ring Control Inner Trend Outer Trend Control Trend

    ~

    • ~ ~

    .c

    +-'

    c 0

    10 8

    6 E

    Q)

    L...

    E 4

    2 0

    Palisades Monthly Therr+minescent Dosimeters Pre-Operational vs. Operational 1968-1969 1991 1992 1993 1994 1995 1996 Pre-Operational Inner Ring Outer Ring Control Inner Trend Outer Trend Control Trend

    ~~~ ~I ~

    1996 Pali es TLDs ST10 Control vs ST06, ST07 A, ST08 10 9

    8 7

    6 E

    Q) 5

    ~

    E 4

    3 2

    1 0

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-06 4.75 NE ST-07A 4.75 NNE ST-08 1 N ST-10C 55 NNE

    1996 Pali es TLDs ST10 Control vs ST13, ST14, ST15 10 9

    8 7

    6 E

    ~

    5 E

    4 -

    3 2

    1 0

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-13 0.9 NNE ST-14 0.9 ENE ST-15 1.3 ENE ST-10C 55 NNE

    E 9

    8 7

    6

    ~

    5

    • -E 4

    3 2

    1 1996 Pali es TLDs ST10 Control vs ST33, ST34, ST35 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-33 0.9 ENE ST-34 0.9 ENE ST-35 0.9 ENE ST-10C 55 NNE

    E 9

    8 7

    6

    @ 5

    • -E 4

    3 2

    1 1996 Pali es TLDs ST11 Control vs ST01, ST16, ST17, ST18 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-01 0.3 ESE ST-161.5 E ST-17 1 ESE ST-18 1 SE ST-11C 35 E

    E 9

    8 7

    6

    ~ 5 E

    4 3

    2 1

    1996 Pali es TLDs ST11 Control vs ST05, ST23, ST24 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-05 3 E ST-23 3 ENE ST-24 4.5 E ST-11C 35 E

    E 9

    8 7

    6

    ~ 5

    • -E 4

    3 2

    1 1996 Pali es TLDs ST11 Control vs ST36, ST37, ST38 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-36 0.9 E ST-37 0.9 E ST-38 0.9 ESE ST-11C 35 E

    1996 Pali es TLDs ST12 Control vs ST02, ST03, ST04, ST09 10

    --.-~~~~~~~~~~~~~~~~~~~~~~~----.

    E 9

    8 7

    6

    ~ 5 E

    4 3

    2 1

    Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-02 5 SSE ST-03 5 SE ST-04 3.5 SE ST-09 1.5 S ST-12C 30 SSE

    )1(

    1996 Pali es TLDs ST12 Control vs ST19, ST20, ST21 10 9

    8 7

    6 E

    Q) 5 L-*--*-E 4

    3 2

    1 0

    I Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec ST-19 0.7 SSE ST-20 0.7 S ST-21 0.6 SSW ST-12C 30 SSE

    Palisades Sedi nt Gross Beta 1991 -1996 14.0 12.0 10.0

    +-'

    Q) 3: -E 8.0

    ?

    (.)

    a.

    6.0 4.0 2.0 1991 1992 1993 1994 1995 1996 Site South Haven Ludington Site Trend South Haven Trend Ludington Trend

    Palisades Sedi nt Gross Beta 1991 -1996 16.0 ------.---------------------------.

    14.0 12.0

    0- 10.0

    (])

    ~

    E 8.0

    !?}

    ()

    c..

    6.0 4.0 2.0


    .---------.----------------~
                                                      • * **-~---****************-~---**********************--*~*-****************** *******-* ***** **************-*********************-******** * ************** ***************** * ***

    1991

    • rr I

    1992 I :

    • 1993 1994 1995 Site South Haven Ludington 1996 1997

    5.0 4.5 4.0 3.5 f 3.0 E 2.5 O>

    ~ 2.0 1.5 0.5 0.0 1991 Palisades Fi.

    Gross Beta

    ~1:99~1~-1:99~6~~~~~~~~

    1993 1992 Ludington Trend S*te Trend Ludington I

    Site 1994 1995

    -~, ---

    1996

    0.24 0.22 0.20 0.18 0.16

    ~ 0.14

    -E 0.12

    ~

    0 0.10

    a.

    0.08 0.06 0.04 0.02 0.00 Palisades h Cs-137 Pre-Operational vs. Operational

    /

    1968-1969 1991 1992 1993 1995 1996 Pre-Operational Site Ludington Site Trend Ludington Trend

    5.0 4.5 4.0 3.5 -

    ~ 3.0 3:

    E 2.5

    !?}

    ~ 2.0 1.5 1.0 0.5 1991 1992 Palisades Fi Gross Beta 1993 1991 - 1996 1994 Site Ludington I

    1995 1996 1997