ML18054B367

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluations Accepting Util Responses to Items 4.5.2 & 4.5.3 of Generic Ltr 83-28 Re on-line Functional Testing of Reactor Trip Sys,Including Independent Testing of Diverse Trip Features of Reactor Trip Breakers
ML18054B367
Person / Time
Site: Palisades 
Issue date: 01/12/1990
From: De Agazio A
Office of Nuclear Reactor Regulation
To: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18054B368 List:
References
GL-83-28, PAL-90-001, PAL-90-1, TAC-54009, NUDOCS 9001190121
Download: ML18054B367 (3)


Text

_;

,)

Docket No. 50-255 Serial No. PAL 90-001 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201

Dear Mr. Berry:

January 12, 1990

SUBJECT:

SAFETY EVALUATION FOR GENERIC LETTER 83-281 ITEMS 4.5.2 AND 4.5.3, REACTOR TRIP RELIABILITY, ON-LINE TESTING \\TAC NO. 54009)

Generic Letter 83-28, Item 4.5, contains a staff position requiring on-line functional testing of the reactor trip system including independent testing of the diverse trip features of the reactor trip breakers.

By letters dated February 19, 1985 and July 1, 1985, Consumers Power Company responded to the staff position regarding Item 4.5.2. The response to Item.

4.5.3 was provided as part of the Combustion Engineering Owners' Group Reports*

CE NPSD-277 and CEN-327.

The NRC staff, with the assistance of the Idaho National Engineering Laboratory, has reviewed your responses and the CE Owners' Group reports and concludes that they are acceptable. The basis for our

~onclusion is provided in the enclosed Safety Evalu*ations and in*contractor's.

reports EGG-NTA-7463 and EGG-NTA-8341.

We, therefore, consider Generic Letter.

83-28, Items 4.5.2 and 4.5.3 to be closed by this action.

cc: B. Mozafari DISTRIBUTION mockET_FILE]

-Nlfc &-LOCAL-PDRs PD31 GRAY FILE JZWOLINSKI PSHUTTLEWORTH PE/PD3~ft" AMASCIANTONIO l/.5'190 ACRS(lO)

OGC ADEAGAZIO AMASC I ANTONIO PM/Pal!!;;

ADEAGAZIO l/5'/90,.

9001190121 900112

(.

PDR ADOCK 05000255 I P

PN~

Sincerely, Albert W. De Agazio, Sr. Project Manager Project Directorate III-1 Division of Reactor Ptojects - III, IV, V & Speci a 1 Projects -

Office of Nuclear Reactor Regulation

. i PALISADES SE FOR GL 83-28

UNITED STATES

  • NUCLEAR REGULATORY COMMISSION Docket No. 50-255 Serial No. PAL 90-001 Mr. Kenneth W. Berry Director, Nuclear Licensfng Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201

Dear Mr. Berry:

WASHINGTON, D. C. 20555 January 12, 1990

SUBJECT:

SAFETY EVALUATION FOR GENE~IC LETTER 83-28, ITEMS 4.5.2 AND 4.5.3, REACTOR TRIP RELIABILITY, ON-LINE TESTING (TAC NO. 54009)

Generic LEtter 83-28, Item 4.5, contains a staff position requiring on~line functional testing of the reactor trip system including independent testing of the diverse trip features of the reactor trip breakers.

By letters dated February 19, 1985 and July 1, 1985, Consumers Power Company responded to the staff position regarding Item 4.5.2. The response to Item 4.5.3 was provided as part of the Con~ustion Engineering Owners' Group Reports CE NPSD-277 and CEN-327.

The NRC staff, with the assistance of the Idaho National Engineering Laboratory, has reviewed your respor.ses and the CE Owners' Group reports ar.d concludes that they are acceptable.

The basis for our conclusion is provided in tlie enclosed Safety Evaluations and in contractor's reports EGG-NTA-7463 and EGG-NTA-8341.

We, therefore, consider Generic Letter 83-28, Items 4.5.2* and 4.5.3 to be closed by this action.

cc: B. Mozafari Sincerely,

~frilf~

Albert W. ~Ag~~io~-~4;*Manager Project Directorate 111-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation

Mr. Kenneth W. Berry Consumers Power Company cc:

M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Conrnission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Township Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. Gerald B. Slade Plant General Manager Palisades Plant 27780 Blue Star Memorial Hwy.

Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Conrn1ss1on Palisades Plant 27782 Blue Star Memorial Hwy.

Covert, Michigan 49043 -

Palisades Plant Nuclear Facilities and Envirorunental Monitoring Section Office Division of Radiological Health P.O. Box 30035 Lansing, Michigan 48909