SAFETY EVALUATION REPORT 11 CESEC DIGITAL SIMULATION OF A COMBUSTION ENGINEERING NUCLEAR STEAM SUP? LY SYSTEM 11 (TAC No. : 01142)

Enclosure I

BACKGROUND Combustion Engineering submitted CENPD-107 on June 30, *1976.

CENPD-107 docu-ments the analytical equations and assumptions used in the CESEC computer program.

CESEC is a simplified thermal-hydraulic transient computer program developed for analyzin~ FSAR Chapter 15 transient and accident events.

following the submittal in 1976, the CESEC computer program underwent exten-sive mDdi f i cat i ans which were. re qui red to mode 1 ATWS, steam 1 i ne break, and operating reactor events.

These modifications were documented in 6 supple-ments to CENPD-107.

As the code was upgraded to calculate increasingly complex hydraulic behaviors, the code identifier was accordingly* changed (i.e., CESEC, CESEC-I, CESEC-ATh'S, CESEC-II and.CESEC-III).

The latest version of CESEC is designated CESEC-III and was submitted on the System 80, St.. Lucie-2, \\~aterford-3, and Arkansas-2 *dockets, as referenced below.*

This SER addresses the CESEC-III computer program.

As part of this review, the acceptability of previous analyses performed on older versions of the code was assessed.

The staff 1 s review has concluded that 1icensina calculations of non-severe transients such as a decrease in feedwater temperature, increase in feedwater flow, turbine trip, loss of normal AC *power, reactor pump shaft seizure, CEA withdrawal and rod ejection accidents would not be altered if reanaiyzed with CESEC-III.

The events which could show significant differ-ences in results are severe depressurization events and events which lead to voiding in the reactor vessel upper head (e.g., steam line break, steam gener-ator tube rupture, and letdown line break events).

For plants licensed with older versions of CESEC, the more severe transient and accident events have been reanalyzed on CESEC-111.

The results of these analyses were in compli-ance with present regulatory requirements.

  • This review did not address the use of CESEC-III for analyzing anticipated transient without SCRAM (ATh'S) events.

To model ATWS pressurization events, CESEC-III would require a more detailed steam generator model, similar to that developed in CESEC-ATWS, an oldeT but specific version of the code.

The following is the staff 1s evaluation of CESEC-III.

References:

lC/27/33 1-Letter from A.E. Scherer (CE, CESSAR Docket) tG D.G. Eisenhut (NRC) 11 CESEC, 11 January 6, 1982 (LD-82-001) 2-St. Lucie 2 FSAR, Section 15D.ll, Amendment No. 3.

3-Letter fro~ L.V. Maurin (LP&L, Waterford-3 Docket) to G. Knighton (NRC, "CESEC, 11 February 2, 1983 (vJ3P83-0247) 4-Letter from J.R. Marshall (AP&L, Arkansas-2 Docket) to J. Miller (J:U:LCJ_._

11 CLS_E_C." December 27, 1983 (2CAN128310).

8402160387 840214

~

L'FS'._<

PDR ADOCK 05000255 P

PDR

e*.

II

SUMMARY

OF CESEC-III AND THE TOPICAL* REPORT CESEC-III, a thermal-hydraulic computer program, was developed for analysis of FSAR Chapter 15 transient and.accident events, as identified.in NUREG-0800, the 11 Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants, LWR Edition 11 (SRP).

The code is a fixed node program designed to calculate the thermal-hydraulics of a two-by-four loop nuclear steam supply system (NSSS) designed by Combustion Engineering (CE).

The code solves the thermal-hydraulic mass, momentum (limited) and energy equations using homogeneous-equilibrium assumptions.

Point kinetics are used for neutronic calculations.

The primary system components modeled include the reactor vessel, reactor core, primary coolant legs, pressurizer, steam generators and reactor coolant pumps (as shown in Figure 1).

The secondary components modeled are shown in Figure 2.

These include the shell of the steam generators, the feedwater system, the maih steam system and control valves.

The code also calculates some of the control and plant protection systems.

The topical report documents the equations and assumptions comprising CESEC-III.

The major differences between CESEC-I, CESEC-II, and CESEC-III are also summarized.

Validation of CESEC-III with operating reactor transients and approved thermalhydraulic computer codes, such as CEFLASH and COAST, are also presented.

Finally, the report describes the input, output and plot package for program execution and an*a lysi s.

The following is the staff's evaluation of CESEC-III,-*its analytical models, code validation, analytical audits, audit of the quality.assurance procedures applied in the development and use of CESEC-III, and the staff's conclusions.

ic:/2712.3 II-1

'11tll"4~Vl**ll-(l...IGl'IJI*~11:;;;1'-::

C *ll-

,.,_.r PllOPORTIONAL l-IEATEllS STEAM GENEll/\\TOn SHUTDOWN noos I*

llC:/\\GTOn

. COO LANT PUMPS flEGENCrl/\\TIVE I !EAT EXCH/\\NGER r

In _,

0 0 --

...;!: z Cll/\\nGING~~

PUMPS u-J 0 :r:

)>

n G) z G) en

)>

fl I

-I I.. ~~

"Tl

~I 2

z c

L rT1 rn o

. ~ n,EACTOll VESSEL -I 0

~

. SAFETY Z

INJECTlbN PUMPS AND TANl<}-ll-ATMOSPHERIC STEAM TUnOINE MAIN FEEDWATEn AUXILIAflY ---~

FEEDWATEll STEAM GENE11/\\TOn MAIN*

FEEOW/\\TEfl

---*t-*

AVXILIAllY FEEDW/\\TEn DUMP MAIN STEAM VALVES SAFETY.

    • ~ALVES MAIN STE/\\M ISOLATION VALVE*

FIGURE 2 SECONDARY SYSTEM COMPONENTS 11-3 TUrlBINE ADMISSION AND STOP VALVES STEAM UYP/\\SS VALVES

III CESEC-III APPLICATION This report assesses the acceptability of CESEC-lII to perform FSAR Chapter 15 licensing analyses for the following events:

1.

Decrease in feedwater temperature (SRP Section 15.1.1)

  • 2.

Increase in feedwater flow (~RP Section 15.1.2)

3.

Increase in main steam flow (SRP Section 15.1.3)

4.

Inadvertent opening of a steam generator atmospheric dump valve (SRP Section 15.1~4)

5.

Steam system piping failures (SRP Section 15.1.5)

6.

Loss of external. load (SRP Section 15.2.2)

7.

Turbine Trip (SRP Section 15.2.3)

8.

Loss of Condenser Vacuum (SRP Section 15.2.5)

9.

.Loss of Normal AC Power. (SRP Section 15.2.6)

10.

Loss of Normal Feedwater Flow (SRP Section 15.2.7)

11.

Feedwater System Pipe Breaks (SRP Section 15.2.8)

12.

Total and Partial Loss of Forced Reactor Coolant Flow (SRP Section 15.3.1)

13.

Reactor Pump Shaft Seizure (SRP Section 15.3.3)

14.

Uncontrolled CEA Withdrawal (SRP Section 15.4.1 and 15.4.2)

15.

CEA Misoperation (SRP Section 15.4.3)

16.

B6ron Dilution (SRP Section 15.4.6)

17.

Spectrum of Rod Ejection Accidents (SRP Section 15.4.8)

18.

Volume Control System Malfunction (SRP Section 15.5.2)

19.

Break of a Letdown Line (SRP Section 15.6.2)

20.

Steam Generator Tube Rupture (SRP Section 15.6.3) 10/27 /P,3 I Il-1 CES!:C

The acceptability of CESEC-III to model anticipated transients without Scram (ATWS) events was not reviewed.

CE has an approved version of CESEC (SESEC-AT\\..'S) for calculating the pressurization response *to ATh'S events.

For CE.SEC-III to calculate ATWS events, the steam generator model would require upgrading.

Consequently, the code, as documented in the January 6, 1982 transmittal

( LD-82-001) from A. E. Scherer to D. G. Ei senhut,* is not approved for ATWS analysi-s.

The staff concludes that CESEC-III is acceptable to perform licensing calculations of the above events.

This approval is conditional upon an appro-priate methodology of implementation which provides conservative results.

This includes appropriate input and in specific, steam and feedwater line break methodologies.

These methodologies are under staff review and docu-mented in Appendices 158 and 15C of the System 80 CESSAR.

The feedwater line break methodology has been approved and an SER for the steam line break method-ology is nearing completion.

CESEC-III is not a best-estimat~ computer program for all events.

However, with appropriate input and boundary conditions, the CESEC-III computer program will generate conservative results.

The following describes the analytical models in *cESEC-III.

t0/27/83 II I-2 CE SEC

IV REVIEW OF THE CESEC-III ANALYTICAL MODELS The fixed nodalization developed in CESEC-III is shown in Fig. 3.

The.reactor vessel is symmetrically split with nodes (volumes) representi~g th~ downcomer, inlet plenum, core, outlet plenum, and vessel head.

The vessel head is common to both loops.

The purpose of the symmetric division is to model asymmetric thermal-hydraulics in the reactor_ vessel.

This is achieved by junctions which transfer a specified fraction of flow between the parallel vessel components.

The specified fractions, known as mixing factors, are input to the code.

This review does not address the selection of mixing factors:

That is being reviewed as pa.rt of the methodology of implementation (i.e., steam line break methodology).

Each hot and cold leg of the primary piping is modeled as a single node.

Each steam generator is modeled as two nodes representing the tube section and two nodes for the inlet and outlet plena.

The pressurizer is modeled as one node composed of two regions to simulate non-equilibrium conditions.

The surge line, which connects the pressurizer to the hot leg of the reactor coolant system is not modeled as a separate node.

Its response is calculated as a separate routine in the pressurizer model.

The shell of each steam generator is modeled as a single node.

A flow path has been incorporated between the primary and secondary sides of the steam generator to simulate steam generator tube rupture events.

The code can mode 1 the stored energy in the reactor coolant system walls, approximate the heat transfer at the steam generat6r tubes, and model the energy generated in the core.

The following is a brief description of these models.

1.

Field Equations (a)

Neutronics Model CESEC-III calculates core neutronics using the point kinetics model.

This model permits up to six groups of delayed neutron precursors.

Gamma heating of the moderator is modeled as a constant fraction of the total power.

The reactivity feedback from changes in the fuel temperature (Doppler) is calculated using a single-pin/single-axial-node model.

The Doppler reactivity is calculated for each radial node within the fuel pin and then volume averaged.

The code computes the moderator feedback using either the core average moderator temperature or the core average moderator density.

~

For steam line break events~ the code calculates the moderator reactivity feedback using the cold edge ternperat~re.

As defined by CE, the cold edge temperature is the coolant temperature at the core center plane along the core radial edge adjacent to the broken steam generator cold legs.

This temperature subtracts out the inlet plenum mixing effects.-

The calcula~

tion of the cold edge temperature is based on several approximations.

It

  • assumes steady state symmetrically split core flow, mirror asymmetric planar enthalpy distribution, neglects core bypass flow and does not 10/27 /23 1 V-1 CESEC

I - --- -----*- *-

f. S'"'.. *L *---ow. A-i=R l

1.,;1,-r-:::.::.*

1....

I

~

I

\\

e._

ls I ~ 1-----r' 22 24 21 20; SI LETDOWN CHARGING

'(t*

i3 SI I v 1G

. LETD~\\~ b. T CHARGING SI 07./25/83.

25

!\\

19

./XJ 18 17 15

4 FIGURE 3 CESEC Nodal IV-2 s

.~

7 8

9 6 -

5

. ~

3 -

SI CHARGING SPRAY 2

.'**SI -

~

4 CHARGJN~

1 SPRAY SI Scheme CESEC

  • e suo~ract density driven cross flow (separate from the asymmetric inlet plenum mixing flows) in the downcomer.

As an option, an additional refinement can be made to account for 3 dimensional (3-D) neutronic effects.

The 3-D reactivity feedback is determined by coupling other neutronic and thermal-hydraulic codes to correlate-the core radial tem-perature tilt, core flow and the core average power to flow ratio.

The temperature tilt is defined to be the difference between the hot edge and cold edge temperatures at the core inlet.

Since this refinement is an example of a specific code application, this procedure was not examined as part of the generic code review.

Reactivity contributions from control rod movement (input as a function of time and signal delay) and boron concentration (as calculated by the boron transport model) are modeled in the code.

The code does not model

.subcooled voids.

Reactor trip can occur from several input signals, which include high power, high or low pressurizer pressure, low coolant flow, low steam generator pressure, low steam generator level and manual initiation.

The kinetics equation is coupled to the 1971 ANS Standard for decay heat.

Up to 11 fission* product groups can be specified.

The 11 group decay constants used are from the ANS Standards for infinite reactor operatic~.

The staff finds the applicant's model for neutronics and decay heat acceptable.

The modeling of cold-edge temperature a~d reactivity control is also acceptable.

(b) Thermal-Hydraulics The thermal-hydraulics for the reactor coolant system (RCS), excluding the pressurizer and its associated surge lina, are calculated using homogeneous equilibrium model (HEM) assumptions.

CESEC-III calculates a single RCS pressure, from which the thermodynamic states and fluid proper-ties are derived.

This assumption decouples the momentum equations from the mass and energy equations.

The code does not solve individual junction momentum equations per se:

The RCS flows are driven by the calculated pump and gravity heads using separate loop 11mechani cal energy" equations (there are no vector effects).

The equation for mechanical energy balance assumes the flow throughout the loop changes uniformly and is composed of a pump model, gravity terms, geometric 'and D'Arcy friction pressure losses.

The code also calculates two-phase flow resistance.

The energy input from the reactor coolant pumps, when modeled, are input as added core heat.

Otherwise, they are neglected.

Flow from the upper plenum (upstream half) to the reactor vessel head is a user specified input fraction of the upper plenum flow.

T~e flow from the reactor vessel head to the upper plenum is symmetrically distributed between the two plena (split vessel model).

The plena mixing flows, which simulate asymmetric vessel thermal-hydraulics, are a fixed user input fraction of flow diverted between the two halves of the vessel. *1he core bypass flows are also modeled as fixed fractions of the split core flow.

The code imposes a fixed pressure drop across the divided core.

10/27 /23 I \\I-3 CESEC

This review finds the simplified model of the system hydraulics accept-able.

This conclusion is based upon code verification submitted by CE and audit analyses, to be described later.

The applicability of the code is limited to transients which do not result in two-phase fluid conditions in the cold legs of the reactor coolant system.

For events leading to two-phase conditions in the cold legs, the applicant will need to submit fl!rther justification of the acceptability of the results.

(c)

Thermal Conduction Model CESEC-III has the capability to model heat capacities in the primary system walls, the steam generator tubes, and the reactor vessel upper head internals.

Energy conduction from the component metal walls is

  • solved using the Fourier equation.

The wall energy distribution is calculated using 13 radial nodes which include two nodes in the cladding.

Constant nodal properties are used and the distribution is solved expli-citly.

The thermal capacity of the control element assembly (CEA) shroud is modeled by assuming instantaneous equilibrium with the fluid.

Heat conduction in the steam aenerator tubes is modeled as a heat slab which assumes rapid equilibri~m (tube time constant --1 second) with the primary fluid.

Conduction through the tubes is modelled quasistatically with the tube resistance determined by the system initialization procedure.

The core heat generation model is a constant dimension single pin with a single axial node and a single coolant node.

The pin is modeled as three equivolume radial nodes with the cladding and gap homogenized into the third node.

The homogeriization procedure for the third node is essentially quasistatic.

To account for the energy distribution in this node, the clad temperature is back calculated from the heat flux to the coolant.

The back calculated temperature is then used in the* calculation of the energy *balance for the third node_.

Equivalent conductivities are used in the lumped parameter heat conduction calculation with a fixed fraction of the neutronic power being deposited in each pin node as well as in the single coolant ~ode.

To couple this model with the thermal-hydraulic model of a split core, an average core enthalpy is used to calculate the temperature for the single coolant node.

The heat transferred to the coolant is then symmetrically split between the two core halves.

The staff has concluded that the simplified assumptions used in CESEC-III can be acceptably applied in licensing and scoping safety analyses.

Our conclusions are based upon the technical derivation of the governing equations and independent audit analyses, to be described later.

2.

Material Properties The thermodynamic properties used in CESEC-111 are based on the McClintock/

Silvestri formulation.

The saturation properties, temperature, enthalpy, and specific volume agree with the ASME steam tables to within tenths of a percent for a wide range of conditions.

This is acceptable.

10/27/83 lV-4 CESEC

For subcooled and superheated regions, the agreement in specific heat is within two of percent.* The thermodynamic derivatives are similar to those applied in CEFLASH-4AS for pressures above 550 psia.

For pressures below 550 psia, the thermodynamic properties are obtained from equations developed by the Brookhaven National Laboratory as-incorporated into the THOR computer program (BNL-NUREG-50534, July, 1976).

This is acceptable.

Transport properties were obtained from the McClintock/Silvestri formu-latio~ and the 1967 ASME steam tables.

The staff's examination shows that in general the values compare well with the ASME steam tables, except for the temperature r~nge of 80°-200°F where it appears that the viscosity is off by - 20%.

This inaccuracy will not affect the analyses of the transients for which the code is applied.

There may be a mismatch in formulation at 600°F and 1200 psi where both th*e therma 1 conductivity

.and viscosity errors increase.

As this is quite isolated, it is not expected to influence the results of the analysis.

3.

Heat Transfer Correlations CESEC~III models the.primary to secondary heat transfer using the Dittus-Boelter forced convection model for subcooled primary system conditions and the Akets, Deans and Crosser Correlation for two-phase flow with condensation.

The secondary system heat transfer is modeled using the C-E modified Rohsenow correlation for pool boiling.

D~ring reverse (secondary to primary) heat transfer regimes, CESEC-lII applies the Dittus-Boelter correla.tion on the primary side during subcooled forced

.convection conditions and Hoeld's modification to the Chen correlati*on during two-phase conditions.

The secondary system heat transfer is modeled using the McAdams single-phase free convection correlation.

The criterion for switchover between the various models is based on bulk saturation temperature and the direction of heat transfer.

In addition, the code can model the heat transfer resistance as a function of speci-fied variables, such as secondary system liquid inventory.

This option is applied to feedwater line break events.

The Dittus-Boelter correlation, as applied by CE, does not differentiate between modes of heating versus cooling.

This limitation is.considered second order.

Similarly, CE's use of the McAdams correlation neglects the low Grashof number region.

This also has a second order contribution to the total heat transfer.

The applic~tion of both the Dittus-Boelter and the McAdams correlations are standard and acceptable.

The McAdams correlation has previously been approved for CEFLASH-4AS and is acceptable for CESEC-JII.

CE extended their applicati6n of the.Akets correlation to a Reynolds number region where Akets recommended the use of the Eckert correlation.

This results in a calculated heat transfer coeffi~ient which underpredicts data.

Cf's modification to the Rohsenow pool boiling correlation has been found to be within 10 percent of the me*an of appropriate data in the pres-sure range of 300-900 psia and a heat flux range of 3 x 104 thru 5.Z x 104 Btu/hr-ft2.

In the pressure range of 800-1200 psia and heat flux range of

2. 7 x 104 thr.u.8.6 x 104 Btu/hr-ft2, the deviation from the mean is on the order of 30%, within the range of data uncertainty.

10/27/83 T\\1-5

The staff has uncovered a sign error in CE's modelino of the Chen correia-tion, as modified by Hoeld.

This error affects the 5oilino induced micro-convection compon.ent of the heat transfer coe.ffic.ient for ~vents which lead to primary system two-phase conditions and reverse heat transfer.

CE has corrected this error and has demonstrated bn the CESSAR docket (steam line break events) that this error does not alter the conclusions of the analyses.

Only single phase liquid.forced convection is.modeled in the core.

An approximation to the Dittus-Boelte~ is used.

CE contends that this approximation is good to a few percent in the pressure range of one atmosphere to 3200 psia and in the temperature range from 200°F to a temperature just below saturation.

CE's justification appears to be Valid except in the temperature range of 700°F where the error jumps to several tens o7 percent.

The temperature range is outside the expected range for operational transient analysis.

The inaccuracies of the model are compen-sated by the conservative application of the code.

The staff concludes that the simplified assumptions applied in CESEC-III for modeling heat transfer is not a best-estimate of expected physics but*

an approximation to it.

For mild transients, its application is acceptable.

For severe transients, such as steam line breaks and feedwater line breaks, the code could have limitations in both the conservative and

  • non-conservative directions.

However, the methodology of application of the code has been shown to result in an acceptably conservative solution.

This is verified by the staff's audit, described in a later sectiqn.

4.

Friction Correlation CESEC-III applies the D'Arcy/Moody model for calculating single-phase fluid frictional flow resistance.

During two-phase.conditions, CE applies a combi*nation of two-phase friction multiplier correlations, which include the Thom correlation for pressures -above 250 psia and the Martinelli-Nelson correlation for pressures below 250 psia.

These models have been previ~usly approved for application in CEFLASH-4AS and are appropriate for application in CESEC-III.

The two-phase form losses are computed using homogeneous equilibrium assumptions.

This is acceptable.

5.

Critical Flow The CESEC-III options for critical fluid flow of steam are the Murdock-Bauman and the CRITCO correlations.

Correlations available for modeling two-phase and*subcooled fluid flow are:

Henry-Fauske/ Moody combination, Henry-Fauske, Moody and the homogeneous equilibrium model (HEM).

These models are applied as a function of the system stagnation enthalpy and pressure.

The gravity heads are neglected since they are negligible re 1 at i ve to the stagnation pressure.

The Murdock-Bauman and the Henry-Faus ke/Moody options were previously approved for use in CEFLASH-4AS and are acceptable for use in CESEC-III.

The HEM correlation is generally considered a best-estimate two-phase fluid flow model.

This typically results in lower calculated flow rates than either the Henry-Fauske or the ~oody models.

The CRITCO correlation was developed for two-phase 10/27/23

flow.

CE has demonstrated that CRITCO is valid for single-phase steam flow, as it predicts within a couple of percent of the D1Arcy formulation for the pressure range between 100 and 1000 psia.

The user of CESEC-III can select any of the flow correlations listed above.

In addition, the user can input a quality dependent discharge co-efficient and a time dependent leak flow area.

CESEC-III has an added option for simulating a leak, such as a l gpm tube leakage used in Chapter 15 licensing evaluations.

This option is applied for dosage calculations and is not factored into the primary system mass and energy calculation.

The critical flow models used in CESEC-III are acceptable.

Each model is recognized as being conservative or nonconservativ~, depending upon the analyzed event., The applicant must clearly identify within the submittal which model is applied and justify the selection.

Comoonent Models (a)

Reactor Coolant Pumos The pump model in CESEC-III is similar to the one used in RELAP4 and CEFLASH-4AS.

The code applies the homologous curves and a two-phase degradation multiplier (the default uses the SEMISCALE data approved by NRC for use in CEFLASH-4AS).

The equations fo~pump ~peed account for electrical torque (a function of speed), hydraulic torque and friction

.windage losses (proportional to the speed squared).

Options are av~ilable for inp~tting pump speed as a function of time; for modelling the pump as a geometric loss (locked rotor); and for simulating a sheared shaft.

The staff finds the pump model in CESEC-III acceptable.

(b)

Pressurizer and Suraeline Models The pressurizer model calculates non-equilibrium thermal-hydraulic condi~

tions.

The model separates the steam and liquid phases into two regions.

Each region calculates a bulk mass and energy balance.

The pressurizer sprays are assumed to instantaneously mix with the steam regi.on.

The pressurizer heaters act on the liquid region to generate steam.

The only energy transfer between the steam and liquid interface occurs by mass transfer of saturated liquid condensinef from the steam dome to the liquid region or transfer of saturated steam bubbles from the liquid region to the steam region.

The pressurizer also models heat transfer from the pressurizer walls and energy release-through the safety/relief valves.

CESEC-III calculates one net mass and.energy balance for the entire NSSS, while constraining to a constant system volume.

The mass from the pres-surizer surge line is incorporated into the pressurizer node.

The equa-tions for frittional pressure drop, geometric losses, elevation heads, and inertial (L/A) terms are all incorpbrated in the equations of mass and energy conservation.

The mass and energy conservation equations are solved simultaneously.

10/27/83 IV-7 CESEC

e*

ne thermodynamic states are ~alculated by predicting the trend of the event and not through iterative steam table lookups.

The trend of the event is evaluated by the governing differential equations using partia1 derivatives of the fluid state.

From the predicted state, CESEC-III calculates the error associated with the updated calculation.

For small errors, the code continues to the n~xt time step.

For the great majority of the time-step calculations, this process results in very small errors.

For. rapid changes in system conditions, the magnitude of the calc~lated error may be beyond the acceptance. limit (typically less than 1% for licensing calculations).

For large errors, the code iterates to a solution until the calculated error is within the acceptance criteria and then proceeds with smaller time steps.

CESEC-III calculates two thermo-dynamic properties for the system.

One for the pressurizer and the other for the primary system.

The primary system thermodynamic properties (outside the pressurizer) are computed from the pressurizer pressure plus the differential developed across the surge line.

The thermodynamic properties in the pressurizer are determined from the pressurizer pressure.

For conditions where the pressurizer is empty and voids develop in the reactor vessel upper head, the primary system pressure is calculated as the hottest coolant temperature in the primary system.

This is typically

'the saturation temperature in the upper head.

The user can maximize the coolant temperature in the upper head by modeling zero mixing between the coo 1 er primary system water and the upper head inventory.

CESEC-I II does not apply the *pressurizer non-equilibrium model in the upper head.

The limitation of not model~ng nonequilibrium condition~ in the upper head is addressed below in Section (h).

The st~ff finds the CESEC-III noh-equilibrium pressurizer model acceptable.

This approval of the thermal-hydraulic model for system pressure and thermo-dynamic states is based on technically acceptable analytical equations and audit calculations, which are addressed later in this report.

(c)

Safety Injection System CESEC-III models the safety injection systems and the reactivity feedback associated with their boron concentration.

The safety injection pumps are modeled as fill tables of flow versus primary system pressure.

This model is* typical of most thermal hydraulic codes.

The safety injection tanks (accumulators) assume an adiabatic expans1on of the fill gas and accounts for pressure differentials due to gepmetric losses and elevation heads.

\\..'hen modeling boron reactivity, the user specifies the volume of pipe between the Boric Acid Tank (BAT) and the reactor coolant system boundary (i.e., cold legs).

Applying the flow rate of the safety injection pumps, the code calculates a delay for boron injection insurge, which is the time required to purge the ECCS lines as the ECCS aligns to the BAT.

The staff finds the CESEC-III model for the safety injection systems acceptable.

lC/27 /23 IV-8

.e (d)

Charcino/Letdown Svstem The letdown and chargi~g flows are modeled as. a function of the pres-surizer water level.

The charging and letdown fluid temperatures are set equal to the cold.leg temperature.

For the letdowo line break event, the code assumes single phase break flow of saturated (liquid) enthalpy which corresponds to the enthalpy at the exit of the regenerative heat exchanger

( RHX).

This 1 eads to a conservatively high break fl ow ca 1 cul at ion.

The empirical formula used by CE for the RHX heat transfer coefficient has been found to give letdown outlet temperatures which agree.with data to within a few tenths of a percent.

The staff finds the model of the Charging/Letdown system acceptable.

(e)

Steam Generator Secondary Model The steam generator secondary side is approximated as a single node.

The secondary is maintained at saturated conditions and the liquid and steam phases are assumed to be ideally separated.

The method for calculating mass and energy balance is identical to the method used for.the primary system.

CESEC-III does not mechanistically model in detail the thermal-hydraul i cs of th*e secondary side.

The steam generator heat* transfer resistance is obtained from the steady-state conditions and set as a constant throughout the analyzed event.

Heat transfer degradation during tube uncovery is modeled as a reduction of heat transfer area.

The reduction of heat transfer area is modeled as a function of secondary liquid inventory.

There is a user controlled variable which 11 triggers 11

  • the initiation 6f heat transfer degradation.

Once a specified threihold inventory is obtained, the heat transfer area is set to zero.

From plant data, a model for level indication was developed.. The model for level indication consists of steady-state data which is a function of load, flow, and liquid inventory.

In addition, a. trip signal on level and inventory can be user specified.

CESEC-III has several means to model the steam generators; none of which can be classified as best~estimate for severe pressurization and depres-surization events.

Consequently, the applicant must clearly identify and justify the assumptions made in the analysis.

(f) Steam Lines CESEC-III models two steam lines, one for each steam generator.

Each line is assumed to be at constant enthalpy and is represented by a quasi-static momentum equation (single secbndary pressure).

The code can account for friction pressure losses.in the lines for break flow calcula-tions.

Compressibility effects are not modeled.

The flow through the turbine valve is user controlled.

The flow is presumed choked using the CRITCO critical flow correlation.

The pressure is solved by applying the Newton-Raphson iteration technique to the set of nonlinear equations.

10/27/83 IV-9 CE SEC I

e*

(g)

Feedwater System The feedwater system is modeled as either a table of time-dependent flows or by an automatic flow controller which is driv~n as a function of the downcomer water level.

The feedwater flo~* can also be set to match the steam flow.

The feedwater enthalpy is input as either a function of time or power demand.

The auxi 1 i ary f eedwater entha 1 py is input as a.function of time while the flow can be specified as a function of time or controlled by the level controller.

(h). Reactor Vessel Upper Head The reactor vessel upper head governs the primary system pressure after pressurizer emptying.

Heat slabs representing the upper head stored energy can be modeled to minimize system depressurization.

The upper head is modeled as a homogeneous-equilibrium node.

No phase separation model is used.

The user can specify only liquid exiting the head, thus simulating complete bubble separation.

In addition, the user can adjust the degree of upper head/upper plenum fluid_mixing to simulate associated bypass flow of lower temperature coolant with the upp~r head inventory.

For depressurization events, as occurs during a steam line break event,

.the coolant in the reactor vessel upper head becomes two-phase.

In addition, the pressurizer is emptied of liquid inventory.

It is the upper head saturation pressure which then governs the primary system pressure response during the remaining transient until the upper head becomes water solid.

CE has determined that minimizing the depressuriza-tion rate during a steam line break event is conservative because it limits the boron injected by the safety injectio_r:i system.

To minimize the depressurization rate, the code user selects a code option which prevents mixing of colder coolant (e.g., core and downcomer bypass flows) with the hotter upper head coolant._ This maximizes the upper head satura-tion temperature throughout the period of upper head inventory dep 1 et ion_.

This depletion r.esults from coolant shrinkage as the primary system undergoes a severe cooldown_

CESEC-III does not use a nonequilibrium model in the upper head as applied in the pressurizer (see Section 6b).

Consequently, the recovery period may not be conservatively calculated when cold primary coolant enters the upper head and instantaneously mixes with the hot steam.

For Chapter 15 li~ensing evaluations, this period of the transient typically follows the time at which.the minimum DNBR (point of interest) occurs.

The staff, therefore, finds this mode 1 acceptab.l e.

However, should future 1 i cens i ng evaluations require an accurate or conservative evaluation of the system pressure response during the period of upper head inventory recovery, further justification and code validation would be required.

Due to the sensitivity of primary system depressurization to upper head mixing, the staff requires j.ustification of the modeling assumptions used for all analyses in which upper head voiding occurs.

2.C1/27/S3 IV-10 CESEC

1.

Soecial Models (a)

Enthalcv Transoort Enthalpy transport is a numerical means to transmi~ energy from one node to another.

Rather than transmitting average *nodal properties (i.e.,

temperature and enthalpy) from a volume containing a heat source (i.e.,

core), the enthalpy transport model calculates the exit fluid conditions and transfers those conditions into the downstream volume.

This modei is applied in the core and steam generators.

This model provides more realistic outlet conditions and thereby a more realistic transient response.

The staff finds this model acceptable.

(b)

Boron Transport CESEC-III can model Boron addition and Boron dilution events.

Boron addition is supplied by the safety injection systems.

If selected, the charging/letdown contribution to these events can be neglected.

The model can account for delays in startup of the SI pumps, diesel genera-tors, and sweepout of the ECC lines as the system aligns with the Boric Acid Tank (BAT).

The Boron concentration is solved using a transport model which assumes instantaneous intranodal mixing or can be input as a function of time.

The staff finds the boron transport model acceptable -when the reactivity changes slowly relative to the transport time o*f boron from the SI system.

Application of this model should assure that the rapid transport of.boron

  • would not significantly* alter the results of the event and that the*

results of the calculation are conservative.

8.

Initialization a _,.

The initialization procedure calculates an effective steam generator tube heat transfer resistance to balance core energy with energy removed by the steam generators.

Inputs to the initialization procedure include cold leg temperature, core power, reactor coolant system pressure and flows, and feedwater enthalpy.

The code iterates on the steam gene~ator and header pressures until steady-state conditions are obtained. *The staff finds this procedure acceptable.

Numerical Technique CESEC-III evaluates the point kinetics equations using the Runge-Kutta/

Merson method which is a modification of the standard fourth order Runge-Kutta method of solution. *This projects an estimated error in the reactivity and power calculation to limit the number of iterations.

The mass and energy equations are written in difference form using node/

flow path techniqoes and the concept of a donor cell.

However, the solution technique was not developed to calculate reverse core flow.

Reverse flow in the loo¢s can be calculated.

The code solves the dif-ferential equations b~ substituting the conservation of mass equations 10/27/83 IV-11 CESEC

and equations of state into the energy equations.

This eliminates most of the temporal derivatives in the equations.

Linearization is then accompiished by using a fractional time step procedure and splitting the variables.

An explicit forward scheme is used.

The surge iine momentum equation closes the set of equations.

CE-uses an iterative procedure to calculate the surge line pressure d~op by using a predictor step to solve the nonlinear set of equations.

The next calculation solves the pump flow exp)icitly.

The steam generator and feedwater system conditions are used to advance the source and coefficient matrices for the mass and energy equations.

During the numerical solution, the code checks for violation of the Second Law of thermodynamics in the steam generator before the enthalpy transport correction is made in the thermal/hydraulic coefficient matrix.

If the Second Law is violated, the outlet enthalpy is set equal to the nodal average enthalpy and the heat transfer is recomputed to satisfy the enthalpy transport model.

If the direction of heat transfer differs from that originally calculated with the steam generator model, the heat transfer is set to zero, otherwise the updated values are used.

CESEC-III has an automatic thermal/hydraulic time step adjuster based on the loop cycle t1me.

CE exercises caution when selecting the size of the time step.

Improper selection of the time step size can lead to large

  • errors in conserving mass and energy.

For scoping studies, accuracy is compromised for running time.

For licensing analyses, errors are limited to less than 1.%.

This has been found acceptable through the audit calcu-lations described later.

10/27/83 I \\1-12 CE SEC

Y CODE QUALIFICATION CE submitted five comparative analyses to qualify the acceptability of-CESEC-IJI for FSAR Chapter 15 licensing calculations.

These included pump model comparisons with COAST, small break LOCA comparison with CEFLASH-4AS, plant data comparisons with a hot-zero power-four pump coastdown test, turbine trip test and a natural circulation cooldown event.

The following is a brief description of these qualification runs.

The CESEC-III reactor coolant pump model was validated by comparing analyses to a.previously approved pump model (COAST) and operational startup data.

Both comparisons showed excellent agreement.

Since the application of the CESEC-III computer program is not intended for events leading to two-phase fluid conditions at the pump, the staff finds the pump model in CESEC-III adequately validated for its intended use.

To validate CESEC--III* for calculating pressurization and depress~rization events, CE, in cooperation with one of its customers, performed a turbine trip test at 98% of rated core power.

As a consequence of an atmospheric dump valve failing to close, the data obtained from this test drifted out of instrumentation range required for detailed code input.

C6nsequently, CE had to. modify the data in a manner consistent with sound engineering practices.

The need for data modification was verified by the Argonne National Laboratory, under contract by the NRC for this review.

Applying the available data and interpretation thereof, CESEC-III was demonstrated to satisfactorily predict the major trends of the test.

The staff finds 'this assessment acceptable.

To.demonstrate CESEC-III 1s capability to predict steam formation in the reactor vessel upper head and during natural circulation cooling, the code was assessed with plant data of a natural circulation cooldown event.

Excellent agreement was obtained when comparing core inlet and core outlet coolant temperatures.

Voiding in the reactor vessel upper head was calculated and validated by the pressurizer level which increased.at a rate four times greater than could be attributed to the addition of primary system inventory.

As with the turbine trip test, the data obtained from the natura~ circulation cooldown event was missing accurate and detailed data required for code input.

Consequently, engineering ~xtrapolation was required.

The staff recognizes that it is ~ot cost effective to instrument operating reactors such that they provide sufficient.and very accurate data for code validation.

However, code comparisons with plant data when applying sound engineering practices are very desirable and can uncover code deficiencies (e.g., the St. Lucie 1 natura 1 c i rcul at ion cool down event led to the deve 1 op-ment of CESEC-III).

To f~rther substantiate CESEC-III 1 s capability to c~lculate depressurization events, CE compared.the code to an analysis performed on CEFLASH-4AS.

CEFLASH-4AS is an approved LOCA code which mor~ rigorously calculates the

  • l(l/27/E.3 V-1 CESEC
    • e e*

thermal-hydraulics of the primary system.

The calculation was of a postulated leak in the cold leg.

This simulated a letdown line break event.

The size of the break was twice the cross-sectional area of the letdown line.

The two codes predicted very similar results.

Differences between the results were primarily attributed to differences in modeling of the secondary system (i.e.,.turbine admission valve), which CEFLASH-4AS has only limited capability.

Excluding the feedback of the admission valve, the maximum deviation between the system pressures predicted by the two codes remained within 60 psia.

The deviation in primary system voiding was consistent with the difference in break flow and corresponding pressure history.

Overall, the calculated trends were similar for the two codes.

Deviations between the code predictions were understood.

The staff finds the validation of CESEC-III adequate and acceptable for use in calculating the Chapter 15 events outlined in Section III.

Our conclusions are based on the acceptability of comparisons with previously approved codes, plant operational data, and the audit calculations described next.

1G/?7/P~

.* ?

CESEC

VI ANALYTICAL STAFF AUDITS The staff performed audits of CESEC-III using the RELAPS computer program (an advanced thermal-hydraulic computer program developed by the Office of Nuclear Regulatory Research at NRC).

These audit calculations were of the System 80 steam and feedwater line break events.

Details of these audits are documented in Appendices H and G of Revision 1 to the System 80 SER.

Figures 1, 2, 3 and 4 illustrate the good agreement between the two codes and the conservative trend predicted by CESEC-III.. The audit calculation attempted to model the events with similar boundary and initial conditions as applied by CE.

The feedwater line break audit confirmed the acceptability of CESEC-III to model severe presturization ev~nts and the steam line break audit confirmed the acceptability of CESEC-III to model severe depressurization events.

The conclusions of these audits confirmed the acceptability of CESEC-III to calculate the thermal-hydraulic responses of the reactor coolant system with the boundary conditions employed.

To predict conservative consequences, the applicant applies *con.servative constraints on the boundary conditions.

The staff 1 s audits confirmed the code's acceptability when applying these constraints.

lG/27 /8:?.

VI-1 CESEC

2900~

i fl 2800 l

I 2700

--~

2600

-<{

(f) 2500 0..

w 2400 a::

J (f)

(f) 2300 w

a::

Cl.

2200

~

JI 2100 2000

)/

I!

I l

1900 1800 0

l I

I l

1

~

._/

I L/

~

\\

I

/

l v

\\REL~

i.---

v i- -...

~

/

LcE*.

I/

/

'~

~

l_

100

~

~

200 1......-

TIME, S FIGUlff 4 300

/

,,,~

/

400 PRIMARY SYSTEM PEAK PRESSURE AS A FUNCTION OF TIME FOR A POSTULATED FEEOWATER LINE BREAK Vt-2 500

~

' 600

2850 2750 ft5 -

VI c. -

LU

i V')

V')

w c...

~

c::::

w c..

V')

u* 2650 c:::

2550 0

07/14/23 0.05 e*

  • O

/

0/

/

/

i I

0 I

~

I '

I

' 0--

1


o I

I I

0 I

I CE RESULTS WHEN APPL YING THEIR LARGE BREAK

  • METHODOLOGY 0--0 = CE RESULTS WHEN APPLY ING THEIR
  • SMALL BREAK METHODOLOGY 0- - -0 = NRC AUDIT RESULTS WHEN APPLYING THE CE LARGE BREAK METHODOLOGY 0.1

. 0.15 0.2 0.25 0.3 BREAK AREA (ft2)

FIGURE 5 PEAK RCS PRESSURE AS A FUNCTION OF FEEDWATER LlNE BREAK SIZE VI-3 0.35

.2GOOE+d4 I..

  • Z400E+04

'<::(

. *2200E+04

\\

\\

NRC

([

I V1 n_

I I

lJJ

~

.zoooE+U4

J tn V1 L

\\

ltJ r~

CL

~

I *J

.1000E+04 N

I*

O"'."

in V1 1 J J o_

a_

.1GOOE+01

.1400E+04

~~

~~

r--


.:~ -

~

~ """"'---

o.
50.

100.

iso.

2od.

  • 250.

300.

360.

400.

TIME (8)

FIGURE 6 PRESSURIZER PRESSURE AS A FUNCTION OF TIME FOR A POSTULATED STEAM LINE BREAK V'J-4

.Z:GOOE+Of

~-*

0..

-.2GOOE+01

(/}

. -.. 6000E+O 1 I-t-1

. I-

-.7GOOE+01

(_)

  • -(

Id n::

_J

-.. lOOOE+02

"'(

I-0

  • 1L..

1 I

v

~

/

  • --_J.,,:/

NRC

. //

CE

_.JL /v I

I

  • -l

//

l

-.. 1250E+02 I

I*--**-

-.1GOOE+02

-.17GOE+02 o..

100.

150.

200.

2GO.

360 *.

400..

300.

60.

e*

TIME CS]

FIGURE 7 TOTAL REACTIVITY AS A FUNCTION OF TIME*FOR A POSTULATED STEAM LINE BREAK VI-5

VII QUALITY ASSURANCE AUDIT On April 28, 1981, the Region IV Office of NRC conducted an inspection-of the Combustion Engineering quality assurance procedures used to develop CESEC.

The audit examined the user's manuals, the theoretical manuals, and the veri-fication analyses for several versions of the CESEC computer program.

Conclu-sions of this inspection are as follows:

a.

There were no nonconformance, unresolved, or follow-up items identified.

b.

The computer program CESEC provides a digital simulation of the NSS£ and is used in the safety analysis performed by CE.

The program is designed to facilitate the analysis of abnormal or accident operational conditions via the study of postulated transients.

c.

The CE Topical Report CENPD-107 and its supplements were found to provide a detailed description of the mathematical models, empirical data, assumptions, and applicable references.

. d.

The training manual (CESEC-II User Course) and the information contained in the topical report, and its supplements, were found to satisfy the "Users Manua 1 11 requi rernents.

e.

The QA of Design Procedure 5.2 (Design Analysis), Revision 3, dated April 2, 1979, was found to impose the requirements of the objectives of the control of computer programs.*

Further details of this inspection are documented in the inspection report number 99900401/81-01, dated May 13, 1981.

Based on the findings of the

  • Region IV inspection,. the staff finds the quality assurance procedures applied in the development and use of CESEC acceptable.

10/27/33 VII-1 rr. c :::c

VIII CONCLUSIONS CESEC-III is the latest version of the CESEC series of thermal-hydraulic computer codes developed by Combustion Engineering for FSAR Chapter 15 analysis.

The staff has reviewed the acceptability of the analyses performed by older versions of the code and has concluded that the majority of these analyses would not be significantly altered if reanalyzed on CESEC-III.

Those events with significant deviations in results (when applying similar assump-tions) have been generically reanalyzed on CESEC-III (with acceptable but different assumptions) and were found in conformance with present regulatory requirements.

These.-events inc 1 ude the steam 1 i ne break event, the 1 etdown line break event and the steam generator tube rupture event.

Most of these events have been reanalyzed a*nd documented in CEN-199, 11 Effects of Vessel Head Voiding During Transients and Accidents in C-E NSSS 1 s, 11 March, 1982.

The review of CESEC-III was limited to FSAR Chapter 15 transients, as defined in NUREG-0800, 11 Standard Review Plan, 11 and listed in Section III of this SER.

CESEC-III was not assessed for analyzing anticipated transient without SCRAM (ATWS) events.

For these events the applicant intends to use the CESEC-ATWS version of the code~ which has been previously approved for licensing application.

The staff concludes that CESEC-III is an acceptable computer program for-~se in licensing applications for calculating FSAR Chapter 15 events.

This approval is conditional upon an acceptable methodology of implementation.

CESEC-III is composed of simplifying thermal-hydraulic assumptions which may not render best-estimate results for all analyzed events.

An example is the modeling of the steam generator heat transfer response during a postulated feedwater line break.

Imposing conservative boundary conditions on the model, as documented in Chapter 158 of the System 80 FSAR, will provide a conserva-tive and acceptable licensing analysis.

For mild transfents, CESEC-III, with best estimate input assumptions, calculates expected transient responses.

CESEC-III is not approved for events which lead to two-phase coolant conditions in the cold legs of the reactor coolant system, nor for events

~eading to two-phase stratified flow in the ~oolant loops.

Should the appli-cant intend to apply this code for such events, further justification is required.

In addition, further justification is required if the code is applied to resolve licensing concerns for_ recovery events where upper head inventory is replenished.

Conditional upon the limitations stipulated in this report, the staff concludes that CESEC-III is an acceptable computer program fer analyzing.

transient and accident.events.

This safety evaluation report may be refer-enced in future submittals as finding the CESEC-III computer program accept-able when implemented in accordance with the conclusions of this report.

The staff requires that all licensing analyses (ATWS events excluded) performed following issuance *Of this SER be analyzed on CESEC-III.

J0/27/23 VII I-l

IX.

ACKNOWLEDGEMENT This Safety Evaluation Report was prepared by Jack Guttman.