Text
December 26, 2017 Dr. Timothy Koeth, Director The University of Maryland Radiation Facilities and Nuclear Reactor Department of Materials Science and Engineering 2309D Chemical and Nuclear Engineering Building Building 090, Stadium Drive College Park, MD 20742-2115
SUBJECT:
EXAMINATION REPORT NO. 50-166/OL-18-01, UNIVERSITY OF MARYLAND
Dear Dr. Koeth:
During the week of November 27, 2017, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your Maryland University Training reactor.
The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 50-166
Enclosures:
- 1. Examination Report No. 50-166/OL-18-01
- 2. Written examination cc: Amber Johnson cc: w/o enclosures: See next page
ML17354A656 NRR-074 OFFICE NRR/DPR/PROB NRR/DIRS/IOLB/OLA NRR/DLP/PROB/BC NAME JNguyen ABaxter AMendiola DATE 12/15/2017 12/21/2017 12/26/2017
University Of Maryland Docket No. 50-166 cc:
Director, Maryland Department of Natural Resources Power Plant Research Program Tawes State Office Building Annapolis, MD 21401 Roland Fletcher Manager, Radiological Health Program Maryland Department of the Environment 1800 Washington Blvd., Suite 750 Baltimore, MD 21230 Amber Johnson Associate Director, Nuclear Reactor and Radiation Facilities University of Maryland Department of Materials Science and Engineering 4418 Stadium Drive College Park, MD 20742-2115 Mary J. Dorman Radiation Safety Officer Department of Environmental Safety Sustainability & Risk University of Maryland 4716 Pontiac Street Seneca Building Suite 0103 College Park, MD 20742 Dr. Ray Phaneuf Professor and Acting Chair University of Maryland Department of Materials Science and Engineering 4418 Stadium Drive College Park, MD 20742-2115 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:
50-166/OL-18-01 FACILITY DOCKET NO.:
50-166 FACILITY LICENSE NO.:
R-70 FACILITY:
Triga EXAMINATION DATES:
November 27-29, 2017 SUBMUTRTED BY:
_______/RA/___________________
_12/18/17___
John T. Nguyen, Chief Examiner Date
SUMMARY
During the week of November 27, 2017, the NRC administered operator licensing examinations to two Senior Reactor Operator-Upgrade (SRO-U), and two Reactor Operator (RO) candidates.
The candidates passed all applicable portions of the examinations.
REPORT DETAILS
- 1.
Examiners:
John T. Nguyen, Chief Examiner, NRC
- 2.
Results:
RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 2/0 0/0 2/0 Operating Tests 2/0 2/0 4/0 Overall 2/0 2/0 4/0
- 3.
Exit Meeting:
John T. Nguyen, Chief Examiner, NRC Timothy Koeth, Director, MUTR Amber Johnson, Training Supervisor, MUTR At the conclusion of the meeting, the NRC Examiner thanked the facility for their support in the administration of the examinations. There is no weaknesses observed during the examination.
Operator Written Examination University of Maryland Week of November 27, 2017
FACILITY COMMENT Question B.08 Which ONE of the following events would be an initiating condition for an ALERT?
- a.
Experiment tube broken that causes radiation levels on the bay radiation area monitor exceed 200 mrem/hr.
- b.
Loss of pool water to be within the capabilities of the normal and emergency makeup water system.
- c.
Sustained fire within the reactor building.
- d.
Threatened compromise of security.
There is no correct answer listed in the distractors (see table 5.1 below). Request the Question B.08 be deleted.
NRC RESPONSE Facility comment accepted.
U. S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY:
University of Maryland REACTOR TYPE:
TRIGA DATE ADMINISTERED:
11/28/2017 CANDIDATE:
INSTRUCTIONS TO CANDIDATE:
Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.
% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 20.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 20.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 20.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 60.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.
Candidate's Signature
A. RX THEORY, THERMO & FAC OP CHARS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
A01 a ___ b ___ c ___ d ___ (0.25 each)
A02 a b c d ___
A03 a ___ b ___ c ___ d ___ (0.25 each)
A04 a b c d ___
A05 a b c d ___
A06 a b c d ___
A07 a b c d ___
A08 a b c d ___
A09 a b c d ___
A10 a b c d ___
A11 a b c d ___
A12 a b c d ___
A13 a b c d ___
A14 a b c d ___
A15 a b c d ___
A16 a b c d ___
A17 a b c d ___
A18 a b c d ___
A19 a b c d ___
A20 a b c d ___
(***** END OF CATEGORY A *****)
B. NORMAL/EMERG PROCEDURES & RAD CON A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
B01 a b c d ___
B02 a b c d ___
B03 a b c d ___
B04 a b c d ___
B05 a b c d ___
B06 a b c d ___
B07 a b c d ___
B08 a b c d ___
B09 a b c d ___
B.10 a ___ b ___ c ___ d ___ (0.5 each)
B11 a b c d ___
B12 a b c d ___
B13 a b c d ___
B14 a b c d ___
B15 a b c d ___
B16 a b c d ___
B17 a b c d ___
B18 a b c d ___
B19 a b c d ___
(***** END OF CATEGORY B *****)
C. PLANT AND RAD MONITORING SYSTEMS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
C01 a ___ b ___ c ___ d ___ (0.25 each)
C02 a b c d ___
C03 a ___ b ___ c ___ d ___ (0.25 each)
C04 a b c d ___
C05 a b c d ___
C06 a ___ b ___ c ___ d ___ (0.50 each)
C07 a b c d ___
C08 a ___ b ___ c ___ d ___ (0.25 each)
C09 a b c d ___
C10 a ___ b ___ c ___ d ___ (0.25 each)
C11 a b c d ___
C12 a b c d ___
C13 a b c d ___
C14 a b c d ___
C15 a b c d ___
C16 a b c d ___
C17 a b c d ___
C18 a b c d ___
C19 a b c d ___
(***** END OF CATEGORY C *****)
(********** END OF EXAMINATION **********)
NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:
- 1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
- 2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
- 3.
Restroom trips are to be MUTR and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
- 4.
Use black ink or dark pencil only to facilitate legible reproductions.
- 5.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.
- 6.
Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
- 7.
The point value for each question is indicated in [brackets] after the question.
- 8.
If the intent of a question is unclear, ask questions of the examiner only.
- 9.
When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.
- 10.
Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.
- 11.
To pass the examination you must achieve a grade of 70 percent or greater in each category.
- 12.
There is a time limit of three (3) hours for completion of the examination.
EQUATION SHEET T
=
H m
=
T c
m
=
Q p
(k) 2
)
(
=
P 2
max seconds 10 x 1
=
-4 sec
-1 eff 0.1
=
)
K (1
CR
=
)
K (1
CR eff 2
eff 1
2 1
K 1
S
=
SCR eff
26.06
=
SUR eff K
1 K
1
=
M eff eff 1
0 CR CR
=
K 1
1
=
M 2
1 eff 10 P
=
P SUR(t) 0 e
P
=
P t
0 P
)
(1
=
P 0
=
eff
+
=
K
)
K (1
=
SDM eff eff K
x k
K K
=
eff eff eff eff 2
1 1
2
0.693
=
T K
1)
K
(
=
eff eff
e DR
=
DR t
0 R
6CiE(n)
=
DR 2
d DR
=
d DR 2
2 2
1 2
1
eff = 0.1/sec 1 Curie = 3.7x1010 dps 1 kg = 2.21 lbm 1 hp = 2.54x103 BTU/hr 1 Mw = 3.41x106 BTU/hr 1 BTU = 778 ft-lbf
°F = 9/5°C + 32 931 Mev = 1 amu
°C = 5/9 (°F - 32)
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.01
[1.0 point, 0.25 each]
Identify whether each of the following conditions will INCREASE or DECREASE the shutdown margin of a reactor.
- a.
Raising moderator temperature (Assume negative temperature coefficient).
- b.
Insertion of a cadmium foil to the reactor core.
- c.
Replacing an old fuel with a new fuel.
- d.
Burnout of a burnable poison.
QUESTION A.02
[1.0 point]
Which ONE of the following statement best defines the reactor excess reactivity? The reactor excess reactivity is:
- a.
a measure of the additional fuel loaded to overcome fission product poisoning.
- b.
a measure of remaining control rod worth when the reactor is exactly critical.
- c.
the combined control rod negative reactivity worth required to keep the reactor shutdown.
- d.
the maximum reactivity by which the reactor can be shutdown with one control rod fully withdrawn.
QUESTION A.03
[1.0 point, 0.25 each]
Replace X with the type of decay necessary (Alpha, Beta, Gamma or Neutron emission) to produce the following reactions.
- a.
92U238 90Th234 + X
- b.
83Bi203 82Pb203 + X
- c.
2He4 + 4Be9 6C12 + X
- d.
84Po210 82Pb206 + X
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.04
[1.0 point]
Given the thermal neutron flux (Ø) is 1.0 x 1013 neutrons/cm2/second, and the macroscopic cross-section (f) for fission is 0.1 cm-1. The fission rate is:
- a.
1.0 x 1012 fissions/cm/second
- b.
1.0 x 1014 fissions /cm/second
- c.
1.0 x 1012 fissions/cm3/second
- d.
1.0 x 1014 fissions /cm3 / second QUESTION A.05
[1.0 point]
If the multiplication factor, k, is increased from 0.800 to 0.950, the amount of reactivity added is:
(given: beta effect = 0.007)
- a.
$2.1
- b.
$2.8
- c.
$21
- d.
$28 QUESTION A.06
[1.0 point]
Reactor power is rising on a 30 second period. Approximately how long will it take for power to triple?
- a.
11 seconds
- b.
33 seconds
- c.
66 seconds
- d.
80 seconds
Section A: Theory, Thermo & Fac. Operating Characteristics Negativ Point B Point A Positive QUESTION A.07
[1.0 point]
The number of neutrons passing through a one square centimeter of target material per second is described as:
- a.
Microscopic cross section.
- b.
Macroscopic cross section.
- c.
Neutron Flux.
- d.
Fission rate.
QUESTION A.08
[1.0 point]
You are assigned to check the operation of a new nuclear instrumentation channel. A few minutes following a reactor scram at full power, the reactor period has stabilized and the power level is decreasing at a CONSTANT rate. What is the time for power to decrease by a factor of 10? (Note: conversion may be needed)
- a.
3 minutes
- b.
60 minutes
- c.
80 minutes
- d.
184 minutes QUESTION A.09
[1.0 point]
Shown below is a trace of reactor period as a function of time. Between points A and B reactor power is:
- a.
continually increasing.
- b.
continually decreasing.
- c.
increasing, then decreasing.
- d.
constant.
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.10
[1.0 point]
A reactor is slightly supercritical, with the thermal utilization factor = 0.700. A control rod is inserted to bring the reactor back to critical. Assuming all other factors remain unchanged, the new value for the thermal utilization factor is:
- a.
0.698
- b.
0.702
- c.
0.704
- d.
0.706 QUESTION A.11
[1.0 point]
Delayed neutrons are considered to cause fission easier than prompt neutrons because delayed neutrons have a:
- a.
higher energies than prompt fission neutrons.
- b.
higher fast non-leakage probability.
- c.
lower reproduction factor.
- d.
lower thermal utilization factor.
QUESTION A.12
[1.0 point]
Two critical reactors at low power are identical except that Reactor 1 has a beta fraction of 0.0072 and Reactor 2 has a beta fraction of 0.0060. An equal amount of positive reactivity is inserted into both reactors. Which ONE of the following will be the response of Reactor 1 compared to Reactor 2?
- a.
The final power level will be lower.
- b.
The final power level will be higher.
- c.
The resulting period will be longer.
- d.
The resulting period will be shorter.
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.13
[1.0 point]
A reactor is critical at 18.1 inches on a controlling rod. The controlling rod is withdrawn to 18.4 inches. The reactivity inserted is 14.4 cents. What is the differential rod worth?
- a.
14.4 cents/inch at 18.25 inches.
- b.
48 cents/inch at 18.4 inches.
- c.
48 cents/inch at 18.25 inches.
- d.
14.4 cents/inch only between 18.1 and 18.4 inches.
QUESTION A.14
[1.0 point]
Which ONE of the following atoms will cause a neutron to lose the most energy in an elastic collision?
- a.
- b.
Ar-40
- c.
O-16
- d.
H-1 QUESTION A.15
[1.0 point]
You are conducting a reactor startup after installing 2 new fuel assemblies in the core. Given the following rod withdrawal data, estimate the rod position when criticality would occur. The initial count rate on the nuclear instrumentation prior to rod withdrawal is 55 cps.
- a.
10 in
- b.
11 in
- c.
12 in
- d.
13 in Rod Withdrawal (Inches)
Count Rate (cps) 0 55 2
58 4
60 6
61 8
69 10 85 12 275
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.16
[1.0 point]
The reactor is critical at 10 watts. A rod is withdrawn to insert a positive reactivity of $0.18.
Which ONE of the following will be the stable reactor period as a result of this reactivity insertion? Given beta effective = 0.007
- a.
10 seconds
- b.
46 seconds
- c.
55 seconds
- d.
66 seconds QUESTION A.17
[1.0 point]
Given the following Core Reactivity Data (not at MUTR):
Control Rod Total Worth ($)
Rod excess ($) at 10 watts)
Rod 1 1.60 Full up Rod 2 3.00 1.80 Rod 3 2.70 1.70 Rod 4 1.20 0.80 Which one of the following is the calculated shutdown margin that would satisfy the Technical Specification Minimum Shutdown Margin? Assume that all rods are scrammable.
- a.
$1.2
- b.
$4.2
- c.
$4.3
- d.
$8.5 QUESTION A.18
[1.0 point]
Which ONE of the following is the principal source of energy (heat generation) in the reactor following a reactor shutdown from extended operation at 100% power?
- a.
Fission product beta and gamma decay.
- b.
Xenon concentration buildup.
- c.
Spontaneous fission of U-238.
- d.
Decay of fission products.
Section A: Theory, Thermo & Fac. Operating Characteristics QUESTION A.19
[1.0 point]
Which ONE of the following describes the response of the subcritical reactor to equal insertions of positive reactivity as the reactor approaches critical? Each reactivity insertion causes:
- a.
a SMALLER increase in the neutron flux, resulting in a LONGER time to reach equilibrium.
- b.
a SMALLER increase in the neutron flux, resulting in a SHORTER time to reach equilibrium.
- c.
a LARGER increase in the neutron flux, resulting in a LONGER time to reach equilibrium.
- d.
a LARGER increase in the neutron flux, resulting in a SHORTER time to reach equilibrium.
QUESTION A.20
[1.0 point]
Which ONE of the following factors of the Six Factor formula is most affected by changing the core materials?
- a.
Thermal Utilization Factor (f)
- b.
Reproduction Factor ()
- c.
Fast Fission Factor ()
- d.
Fast Non-Leakage Factor (Lf)
(***** END OF CATEGORY A *****)
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.01
[1.0 point]
A radiation survey of an area reveals a general radiation reading of 1 mrem/hr. There is, however, a small pipe which reads 10 mrem/hr at one (1) meter. Which ONE of the following defines the posting requirements for the area in accordance with 10CFR20?
- a.
Restricted Area.
- b.
Caution, Radiation Area.
- c.
Caution, High Radiation Area.
- d.
Grave Danger, Very High Radiation Area.
QUESTION B.02
[1.0 points]
Two point sources have the same curie strength. Source As gammas have an energy of 2 Mev, whereas Source Bs gammas have an energy of 4 Mev. You obtain a reading from the same GM tube at 10 feet from each source. Concerning the two readings, which ONE of the following statements is correct?
- a.
The reading from Source B is four times that of Source A.
- b.
The reading from Source B is twice that of Source A.
- c.
The reading from Source B is half that of Source A.
- d.
Both readings are the same.
QUESTION B.03
[1.0 point]
Which ONE of the following surveillances identifies as a channel check?
- a.
Press a manual button to verify the reactor scram.
- b.
Verify an interlock system by moving the neutron source away from the core.
- c.
Compare readings of gamma radiation area monitors at full power.
- d.
Adjust the Linear Power Channel in accordance with recent data collected on the reactor thermal power calibration.
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.04
[1.0 point]
Which ONE of the following conditions will violate the MUTR Technical Specifications?
- a.
The shutdown margin exceeds $1.0.
- b.
Inserting a non-secured experiment worth of $0.80.
- c.
Causing an unintentional pulse with reactivity insertion of $1.10.
- d.
The sum of the absolute reactivity worth of in-core experiments exceeds $2.0.
QUESTION B.05
[1.0 point]
In accordance with 10CFR20.1301, individual members of the public are limited to a TEDE in one year of:
- a.
10 mrem.
- b.
100 mrem.
- c.
500 mrem.
- d.
1250 mrem.
QUESTION B.06
[1.0 point]
An irradiated sample having a half-life of 20 minutes provides a dose rate of 100 mrem/hr at 2 ft.
Approximately how far from the sample must a Radiation Area sign be posted?
- a.
6 ft.
- b.
9 ft.
- c.
18 ft.
- d.
80 ft.
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.07
[1.0 point]
Per MUTR Technical Specifications, which ONE of the following will violate the Limiting Safety System Settings?
- a.
An unanticipated change in reactivity of one dollar.
- b.
Instrumented fuel temperature exceeds 200 °C.
- c.
Steady State power exceeds 120 % full power.
- d.
A major loss of reactor pool water.
QUESTION B.08
[1.0 point] deleted per facility comment Which ONE of the following events would be an initiating condition for an ALERT?
- a.
Experiment tube broken that causes radiation levels on the bay radiation area monitor exceed 200 mrem/hr.
- b.
Loss of pool water to be within the capabilities of the normal and emergency makeup water system.
- c.
Sustained fire within the reactor building.
- d.
Threatened compromise of security.
QUESTION B.09
[1.0 point]
The dose rate from a mixed beta-gamma point source is 100 mrem/hour at a distance of one (1) foot, and is 0.1 mrem/hour at a distance of twenty (20) feet. What percentage of the source consists of beta radiation?
- a.
20%
- b.
40%
- c.
60%
- d.
80%
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.10
[2.0 points, 0.5 each]
Match the 10 CFR Part 55 requirements listed in Column A for an actively licensed operator with the correct time period from Column B. Column B answers may be used once, more than once, or not at all.
Column A Column B
- a.
License Expiration
- 1.
1 year
- b.
Medical Examination
- 2.
2 years
- c.
Requalification Written Examination
- 3.
4 years
- d.
Requalification Operating Test
- 4.
6 years QUESTION B.11
[1.0 point]
Per MUTR Emergency Plan, the area within the confines of the nuclear reactor building and the fenced area enclosing the north side of the reactor building is defined as the:
- a.
Reactor Boundary.
- b.
Emergency Planning Zone.
- c.
Restricted Area.
- d.
Control Access Area.
QUESTION B.12
[1.0 point]
Per MUTR Technical Specifications, which ONE of the following statements is true?
- a.
Liquid fissionable materials shall be doubly encapsulated.
- b.
Explosive materials in quantities less than 5 grams may be irradiated in the reactor or experimental facilities.
- c.
The reactivity worth of any single experiment shall be less than $2.00.
- d.
Each fuel experiment shall be controlled such that the total inventory of Iodine isotopes 131 thru 135 in the experiment is no greater than 5 curies.
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.13
[1.0 point]
Per MUTR Technical Specifications, which ONE of the following events does NOT require the presence of a licensed Senior Reactor Operator in the control room?
- a.
Resumption of operation following unexpected significant reduction in power.
- b.
Performance of the channel calibration for the Radiation Area Monitoring Systems.
- c.
Removal of Safety control rod for inspection.
- d.
Insertion of experiment worth of $0.90.
QUESTION B.14
[1.0 point]
Which ONE of the following is NOT a responsibility of the Emergency Director during an emergency?
- a.
Authorization for reentry and roof access.
- b.
Terminating an emergency and initiating recovery actions.
- c.
Coordinating medical, ambulance, fire, and police assistance as necessary.
- d.
Authorization for emergency exposures in excess of occupational limits during rescue and recovery activities.
QUESTION B.15
[1.0 point]
What is a minimum level of authority that has the power to approve minor changes such as typographical error correction or any other change that does not change the effectiveness or the intent of the procedure?
- a.
Reactor Safety Committee
- b.
Reactor Director
- c.
Reactor Supervisor
- d.
Senior Reactor Operator
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.16
[1.0 point]
The primary coolant ion exchange column should be replaced when the OUTLET conductivity meter exceeds its limit. The limit is set:
- a.
below 5 micromho/cm.
- b.
higher than 5 micromho /cm.
- c.
below 10 micromho /cm.
- d.
higher than 10 micromho /cm.
QUESTION B.17
[1.0 point]
The reactor shall NOT be operated unless the following measuring channels are operable:
- a.
1 linear power channel and 1 fuel element temperature channel
- b.
2 reactor power level channels and 1 fuel element temperature channel
- c.
2 linear power channels and 2 fuel element temperature channels
- d.
2 fuel element temperature channels and 2 log power channels QUESTION B.18
[1.0 point]
How long will it take a 50 Curie source, with a half-life of 5.26 years, to decay to 2 Curie?
- a.
10.5 Years
- b.
15.5 Years
- c.
24.5 Years
- d.
35.5 Years
Section B: Normal/Emergency Procedures and Radiological Controls QUESTION B.19
[1.0 point]
Per UMTR Technical Specifications, the control rod poison section shall be inspected:
- a.
Biennially
- b.
Annually
- c.
Semi-annually
- d.
Quarterly
(***** END OF CATEGORY B *****)
Section C Facility and Radiation Monitoring Systems QUESTION C.01
[1.0 point, 0.25 each]
Match the purification system functions in column A with the purification component listed in column B. (Note: items from column B may be used more than once, or not at all.)
Column A Column B
- a.
Prevent clogging in the demineralizer.
- 1.
Resin in demineralizer
- b.
Remove dissolved impurities
- 2.
Filter
- c.
Remove suspended solids
- d.
Maintain pH QUESTION C.02
[1.0 point]
The MUTR neutron source is located at:
- a.
B row.
- b.
C row.
- c.
D row.
- d.
E row.
QUESTION C.03
[1.0 point. 0.25 each]
Match the item provided in column A, with the correct Nuclear Instrumentation Channel from column B. (Items in column B may be used once, more than once, or not at all.)
Column A Column B
- a.
< 1 cps rod withdrawal inhibit
- 1.
Wide Range Linear Power
- b.
Compensated Ion Chamber
- 2.
Wide Range Log Power
- c.
Uncompensated Ion Chamber
- 3.
Safety Channel 2
- d.
Output signal using Campbell technique
Section C Facility and Radiation Monitoring Systems QUESTION C.04
[1.0 point]
Figure 7.4 depicts the motor control rod and drive circuit. The MAIN function of the capacitor, C, listed in the diagram is to:
- a.
Provide enough phase-shifting with the motor coil M to cause the motor to rotate when UP or DOWN button is depressed.
- b.
Prevent a short circuit when UP and DOWN buttons are pressed simultaneously.
- c.
Prevent manual withdrawal of more than one control rods simultaneously.
- d.
Converse the 115 VAC to 115 VDC for the motor power.
QUESTION C.05
[1.0 point]
The CHANNEL TEST for the Bridge Radiation Area monitor is performed:
- a.
Prior to starting up the reactor
- b.
Daily
- c.
Monthly
- d.
Annually
Section C Facility and Radiation Monitoring Systems QUESTION C.06
[2.0 points, 0.5 each]
Reactor is in operation. Match the input signals listed in column A with their AUTOMATIC response listed in column B. (Items in column B may be used once, more than once, or not at all.)
Column A Column B
- a.
Fuel temperature = 175 °C
- 1.
Indication
- b.
Source count rate = 10 cps
- 2.
Interlock
- c.
Wide Range Linear Channel = 130% power
- 3.
- d.
Beam Port plug is removed QUESTION C.07
[1 point]
Water returning to the pool from the primary system is ejected through an angled nozzle, which causes a swirling motion in the pool. Which ONE of the following is the PRIMARY purpose for this design?
- a.
To increase the heat transfer rate due to increased convective flow.
- b.
To increase the transport time for N16 to reach the surface of the pool.
- c.
To break up O16 bubbles in the pool thereby decreasing the production of N16.
- d.
To decrease the activation rate of O16 to N16 due to a decrease in time within the core.
QUESTION C.08
[1.0 point, 0.25 each]
When reactor is at full power, identify the transfer mechanism (Forced Convection, Natural Convection or Conduction) for each of the following:
- a.
Cooling the Core.
- b.
Cooling the Pool.
- c.
Remove ions by demineralizer.
- c.
Transfer of heat across the tubes of the heat exchanger.
Section C Facility and Radiation Monitoring Systems QUESTION C.09
[1.0 point]
Which ONE of the following will have an emergency power during a loss of the electrical building power?
- a.
Building security system, emergency lights, and exit signs.
- b.
Building security system and Bridge Radiation Area monitor.
- c.
Reactor console, emergency lights, and exit signs.
- d.
Primary coolant pump and Bridge Radiation Area monitor.
QUESTION C.10
[1.0 point, 0.25 each]
Use the following diagram of the control rod armature; match the components listed in Column A to the appropriate position locator listed in the diagram.
Column A
- a.
Barrel End
- b.
Piston
- c.
Armature
- d.
Connecting Rod
Section C Facility and Radiation Monitoring Systems
Section C Facility and Radiation Monitoring Systems QUESTION C.11
[1.0 point]
Coolant flow in the demineralizer loop of the reactor coolant system is measured by:
- a.
a differential pressure across the filter.
- b.
a flow meter at the outlet of the demineralizer.
- c.
an orifice at the inlet to the heat exchanger.
- d.
a flowmeter at the inlet of the primary pump.
QUESTION C.12
[1.0 point]
Thermocouples in an instrumented TRIGA fuel element measure temperature at the:
- a.
surface of the cladding.
- b.
interior of the fuel section.
- c.
surface of graphite reflector.
- d.
center of the zirconium rod.
QUESTION C.13
[1.0 point]
When the OUTLET conductivity of the demineralizer reads 0.1 micromho and the INLET conductivity reads 1 micromho, it indicates that:
- a.
the resin bed has been depleted and it needs to be changed.
- b.
the outlet leg of the demineralizer has been logged.
- c.
the inlet leg of the demineralizer has been logged.
- d.
The demineralizer is operable and no need to change the resin bed.
Section C Facility and Radiation Monitoring Systems QUESTION C.14
[1.0 point]
The Wide Range Log Power channel is used for the neutron flux measurement. What kind of signal from a fission chamber is used for the Campbelling technique?
- a.
It uses an output AC signal from a fission chamber to determine the neutron flux.
- b.
It uses an output DC signal from a fission chamber to determine the neutron flux.
- c.
It counts a number of pulses from a fission chamber to determine the neutron flux.
- d.
It combines an output AC and DC signals from a fission chamber to determine the neutron flux.
QUESTION C.15
[1.0 point]
Which ONE of the following describes the action of the rod control system to drive the magnet draw tube down after a dropped rod?
- a.
When the ROD DOWN limit switch and the MAGNET DOWN limit switch are activated by the reactor console, the rod will drop and the magnet tube drives down simultaneously.
- b.
When the connecting rod reaches the lowermost rest position, the Rod Up limit switch, S901, will reverse. S901A will open the circuit in series with the UP pushbutton and the motor automatically drives the magnet down.
- c.
When the connecting rod reaches the lowermost rest position, the Rod Down limit switch, S903, will reverse. S903A will open the circuit in series with the UP pushbutton and the motor automatically drives the magnet down.
- d.
When the connecting rod reaches the lowermost rest position, the Rod Down limit switch, S903, will reverse. S903A will open the circuit in series with the DOWN pushbutton and the motor automatically drives the magnet down.
QUESTION C.16
[1.0 point]
Which ONE of the following is the main function of the DISCRIMINATOR circuit in the Wide Range Log Power Channel?
- a.
Convert a number of pulses per second to reactor period.
- b.
Convert the signal from a fission counter to LINEAR output over a range of 10 -8 to 150 percent of full power.
- c.
Filter out small pulses due to gamma interactions, passing only pulses due to neutron events within the Wide Range Log Power Channel
- d.
Generate a current signal equal and of opposite polarity as the signal due to gamma generated within the Wide Range Log Power Channel
Section C Facility and Radiation Monitoring Systems QUESTION C.17
[1.0 point]
When the reactor is in the steady state mode, two or more control rods may not be withdrawn simultaneously. The purpose of this interlock is to:
- a.
prevent the possibility of a source-less startup.
- b.
prevent the inadvertent pulsing of a reactor in the steady state mode.
- c.
assure sufficient amount of startup neutrons are available to achieve a controlled approach to criticality.
- d.
prevent violation of the maximum reactivity insertion rate for steady state operation.
QUESTION C.18
[1.0 point]
When going to automatic from manual rod control the Regulating Rod will automatically be limited to a _________ reactor period until the power has reached the demand setpoint on the
% DEMAND controller for the current range selected on the REACTOR POWER RANGE SWITCH.
- a.
5 second
- b.
10 second
- c.
15 second
- d.
25 second
Section C Facility and Radiation Monitoring Systems QUESTION C.19
[1.0 point]
What is the MAIN reason that you would NOT bring the power level to exceed 500 watts during the control rod calibration?
- a.
Taking too long to obtain the reactor period.
- b.
Avoiding the maximum reactivity insertion rate.
- c.
Avoiding temperature induced reactivity effects.
- d.
Preventing the possibility of a rod withdraw prohibit.
(***** END OF CATEGORY C *****)
(***** END OF EXAMINATION *****)
Section A: Theory, Thermo & Fac. Operating Characteristics A.01 Answer:
a, INCREASE; b, INCREASE; c, DECREASE; d, DECREASE
Reference:
DOE Fundamentals Handbook, Volume 2, Module 4, Reactor Theory (Reactor Operations), Enabling Objective 3.6 A.02 Answer:
b
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 6.2 A.03 Answer:
a, alpha b, +1 0 c, neutron d, alpha
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.8 A.04 Answer:
c
Reference:
Fission rate = thermal flux (Ø) x macroscopic cross-section. (f) = 1.0 x 1013 x 0.1 cm-1 = 1.0 x 1012 neutrons/cm3/second Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.6.2 A.05 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-
- 21.
= keff1-keff2/(keff1 x keff2) = 0.95-0.8 /(0.8*0.95)=0.197 Or = $0.197/0.007 = $28 A.06 Answer:
b
Reference:
P = P0 et/T --> ln(3) = time ÷ 30 seconds -> time = ln (3) x 30 sec. 1.1 x 30 33 sec.
A.07 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.6.1 A.08 Answer:
a
Reference:
P/P0 = e-T/
ln(0.1) = - T(time)/(-80sec) Time = ln (0.1) x -80 sec = 184 seconds 3 minutes A.09 Answer:
a
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 4.3 A.10 Answer:
a
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3.1
Section A: Theory, Thermo & Fac. Operating Characteristics A.11 Answer:
b
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3.1 A.12 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 4.9 A.13 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 7.3 Differential position is between 18.1 and 18.4 = 18.25 Differential rod worth (k/k/in) = (k/k) / (rod position)
= 14.4 cents /0.3 = 48 cents A.14 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 2.5.3 A.15 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 5.5 -5.7 A subcritical multiplication factor, k, closer to 1 produces a larger subcritical neutron population, C. You see a big jump from 10 to 12 in. However, at 12 in reactor is still under subcritical k < 1 due to 1/M = 55 cps/275 cps =0.2. Best guess, it must be higher than 12 in.
A.16 Answer:
b
Reference:
Reactivity added = $0.18 x.007 = 0.00126
= (-)/eff = 0.007 - 0.00126 = 45.6 seconds (0.1) (0.00126)
A.17 Answer:
a
Reference:
Shutdown = Total rod worth - rod excess
$8.5 - $4.3 = $4.2 Minimum SDM = Shut down - highest worth of control rod
($1.80 + $1.70 + $.8) - $3 (rod number 2) = $4.20 - $3.0 = $1.2
eff
+
=
Section A: Theory, Thermo & Fac. Operating Characteristics A.18 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.2.1 A.19 Answer:
c
Reference:
NRC Standard Question A.20 Answer:
a
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3.1
Section B Normal/Emergency Procedures and Radiological Controls B.01 Answer:
c
Reference:
DR1D12 = DR2D22 ;
10 mrem/hr at one meter (100 cm.)
results in 111.1 mrem/hr at 30 cm.
B.02 Answer:
d
Reference:
GM tube cannot distinguish between energies.
B.03 Answer:
c
Reference:
TS, Definition B.04 Answer:
c
Reference:
MUTR Tech Spec is not permissible to conduct a pulse.
B.05 Answer:
b
Reference:
10CFR20 B.06 Answer:
b
Reference:
DR1D12 = DR2D22 ;
Radiation area > 5 mrem/hour.
100 mrem (2) 2 = 5 mrem (d) 2 D = 8.9 ft B.07 Answer:
b
Reference:
TS 2.2 B.08 Deleted per facility comment Answer:
a
Reference:
EP 5.0 B.09 Answer:
c
Reference:
10CFR20 - At 20 feet, there is no beta radiation. Gamma at 20 feet =
0.1 mrem/hour, gamma at 1 foot = 40 mrem/hour. Therefore beta at 1 foot = 60 mrem/hour = 60%.
B.10 Answer:
a,4 b,2 c,2 d,1.
Reference:
10CFR55
Section B Normal/Emergency Procedures and Radiological Controls B.11 Answer:
a
Reference:
EP 2.9 cand d cannot be the correct answers because the question asked related to the Emergency Plan, not the Security Plan.
B.12 Answer:
a
Reference:
TS 3.7 B.13 Answer:
b
Reference:
TS 6.1.3 B.14 Answer:
c
Reference:
EP 3.1.3 B.15 Answer:
b
Reference:
TS 6.4 B.16 Answer:
a
Reference:
TS 3.7 B.17 Answer:
b
Reference:
TS Table 3.1 B.18 Answer:
c
Reference:
T A = A*e -t 2Ci = 50Ci* e -(t)
Ln(2/50) = -ln2/5.27 yr*(t) --> -3.2189/-0.1315
solve for t: 24.47 years B.19 Answer:
b
Reference:
SP 201
Section C Facility and Radiation Monitoring Systems C.01 Answer:
a = 2; b = 1; c = 2; d= 1
Reference:
Standard NRC purification system question.
C.02 Answer:
a
Reference:
SAR, Figure 4.9 C.03 Answer:
a = 2; b = 1; c = 3; d= 2
Reference:
SAR 7.4 C.04 Answer:
a
Reference:
SAR 7.2.1.2 C.05 Answer:
a
Reference:
TS 4.6.1 C.06 Answer:
a = 3 b = 1; c = 1; d= 2
Reference:
TS 3.1 and 3.2 and walk through information C.07 Answer:
b
Reference:
SAR 5.6 C.08 Answer:
a = NC; b = FC; c = FC d = Con
Reference:
Standard NRC question C.09 Answer:
a
Reference:
SAR 8.1 C.10 Answer:
a(9) b(6) c(4) d(5)
Reference:
SAR Figure 4.14 C.11 Answer:
a
Reference:
SAR 5.2 C.12 Answer:
b
Reference:
SAR 4.2.1.2
Section C Facility and Radiation Monitoring Systems C.13 Answer:
d
Reference:
SAR 5.4.2 0.1 micromho = 10 M at outlet 1 micromho = 1 M at inlet So, the demineralizer is working!
C.14 Answer:
d
Reference:
Information from walkthrough C.15 Answer:
d
Reference:
SAR 7.3.1.1 C.16 Answer:
c
Reference:
SAR 7.4.1.1.1 C.17 Answer:
d
Reference:
TS, Table 3.4 C.18 Answer:
c
Reference:
OP-104 step 6.5 C.19 Answer:
c