ML17089A783

From kanterella
Jump to navigation Jump to search
University of Maryland Closure of Confirmatory Action Letter No. NRR-04-004 on the Site-Specific Compensatory Measures Implementation Plan for the Maryland University Training Reactor
ML17089A783
Person / Time
Site: University of Maryland
Issue date: 04/19/2017
From: Marilyn Evans
Office of Nuclear Reactor Regulation
To: Koeth T
Univ of Maryland
Takacs M
References
NRR-04-004
Download: ML17089A783 (4)


Text

April 19, 2017 Dr. Timothy W. Koeth, Director University of Maryland Nuclear Reactor and Radiation Facilities Chemical and Nuclear Engineering Building 090 College Park, MD 20742-2115

SUBJECT:

UNIVERSITY OF MARYLANDCLOSURE OF CONFIRMATORY ACTION LETTER NO. NRR-04-004 ON THE SITE-SPECIFIC COMPENSATORY MEASURES IMPLEMENTATION PLAN FOR THE MARYLAND UNIVERSITY TRAINING REACTOR

Dear Dr. Koeth:

The purpose of this letter is to inform you that the U.S. Nuclear Regulatory Commission (NRC) has closed Confirmatory Action Letter (CAL) No. NRR-04-004. The NRC issued CAL No. NRR-04-004 on March 2, 2004 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML033090502). This confirmatory action letter formalized commitments to implement site-specific compensatory measures related to security and safeguards.

By letter dated May 12, 2000, the NRC received an application for license renewal of Facility Operating License No. R-70 for the University of MarylandMaryland University Training Reactor (MUTR) (ADAMS Accession No. ML052910399). As part of the license renewal application review, the NRC staff reviewed the MUTR physical security plan, dated February 10, 2016, and found it to be in compliance with the applicable regulations contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 73, Physical Protection of Plants and Materials. In addition, the NRC staff found that the site-specific compensatory measures committed to in CAL No. NRR-04-004 have also been incorporated into the MUTR physical security plan. Therefore, the NRC considers CAL No. NRR-04-004 closed.

Under 10 CFR 2.390, Public inspections, exemptions, requests for withholding, the NRC will make a copy of this letter available electronically for public inspection in the NRC Public Document Room located at NRC Headquarters in Rockville, MD. The public can also access this letter in the NRCs document system, ADAMS, which is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

T. Koeth If you have any questions, please contact Mr. Anthony Mendiola, Chief of the Research and Test Reactors Oversight Branch, by phone at 301-415-1054 or by electronic mail at Anthony.Mendiola@nrc.gov.

Sincerely,

/RA/

Michele G. Evans, Deputy Director for Reactor Safety Programs and Mission Support Office of Nuclear Reactor Regulation Docket No. 50-166 License No. R-70 cc: See next page

ML17089A783; *concurred via e-mail NRR-106 OFFICE NRR/DPR/PROB/SS* NRR/DPR/PRLB/PM* Tech Editor* NRR/DPR/PROB/LA*

NAME MTakacs CMontgomery JDougherty NParker DATE 4/6/17 3/27/17 3/29/17 3/31/17 OFFICE NRR/DPR/PROB/BC NRR/DPR/D NRR/DD NAME AMendiola LLund MEvans (GBowman for)

DATE 4/10/17 4/17/17 4/19/17 University of Maryland Docket No. 50-166 cc:

Director, Dept. of Natural Resources Power Plant Siting Program Energy & Coastal Zone Administration Tawes State Office Building Annapolis, MD 21401 Roland G. Fletcher, Program Manager IV Radiological Health Program Maryland Department of Environment 1800 Washington Blvd., Suite 750 Baltimore, MD 21230-1718 Vincent G. Adams Facility Coordinator Chemical and Nuclear Engineering Building 090 University of Maryland College Park, MD 20742 Mary J. Dorman Radiation Safety Officer Department of Environmental Safety 3115 Chesapeake Building 338 University of Maryland College Park, MD 20742 Ray Phaneuf Professor and Acting Chair University of Maryland Department of Materials Science and Engineering, Room 2135 Chem. & Nuclear Engineering Bldg (090)

College Park, MD 20742-2115 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611