SHUTDOWNS AND POWER REDUCTIONS June 1991 DOCKET NO 50-530 UNIT NAME PVNGS-3 DATE COMPLETED BY K.A. Chavet No.

Outage Method of Duration Shutting System Date Type Hours Reason Down Reactor LER No.

Code Cause and Corrective Component Action to Code~

Prevent Recurrence 91/03 03/16/91 F

59.5 N/A N/A N/A Continuation of 2n refueling outage.

Outage lasted 1906.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

91/04 06/03/91 S

2.3 N/A N/A N/A Planned turbine overspeed testing.

The reactor remained in Mode 1.

91/05 06/19/91 F

87.4 N/A N/A N/A Faulty switch caused inadvertent Containment Spray Actuation Signal during surveillance testing.

Manually tripped reactor per procedure after verifying containm spray.

XI 0%,~

a~'~F-Forced

~, S-Scheduled DM BIO

. ON nw KGD OC (flMi OQ 0%

QOw,

~ UVIOL,

". Ãn3Q

~Reason:

A-Equipment Failure(Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Examination F-Administrative G-Operational Error H-Other (Explain)

~Method:

1-Manual 2-Manual Scram 3-Automatic Scram 4-Continuation from Previous Month 5-Reduction of 20% or Greater in the Past 24 Hours 9-Other-(Explain) 15 4Exhibit F-Instructions for Preparation of the Data Entry Sheets for Licensee Event Report (LER) File (NUREG 0161) sExhibit H-Same Source

I t

T C

~