REGULATOR NFORMATION DISTRIBUTION TEM (RIDS)
ACCESSION NBR:8504050215 DOC ~ DATE! 85/04/03 NOTARIZED! NO DOCKET
.FACIL!STN.50 529 Palo Ve'rde. Nuclear>> Station~
Uni;t 2~ Arizona Publi 05000529 AUTH',NAME, AUTHOR AFFILIATION VAN BRUNTgE.E.
Arizona Public Ser vice>> Co, RECIP ~ NAME" RECIPIENT. AFFILIATION KNIGHTONg G ~ N ~
Licensing Branch 3
SUBJECT'.
Forwards "Evaluation of="Spray 'Pond lleld Corrosioni" per telcon r equestgInvestigation, identified weld leak in 8~inch diameter stainl ess ste'el pipe inside essential spr ay pond, DISTRIBUTION CODf:! B021D
-COPIES RECEIVED!LTR
('
ENCL 9 SIZE';,, l,~g>
TITLE': OR/Licensing Submi-teal j Combined Gene'ral Distribution NOTES!Standardized pl-ant; 05000529 RECIPIENT'D CODE'/NAMEI NRR'B3 BC 05>>
LICITRAiE'01-INTERNAL: ACRS
'29 ELD/HDS3 NRR/DE/MTEB'RR/DHFS/HFEB16'RR/DL DIR NRR/DL/SSPB NRR/DS I'/AEB 28 NRR/DSI'/CSB 10.
NRR/DSI/METB 13>>
NRR/DS I'/RSB 25 RGN5
>>COPIES LTTR ENCL 1
1 1
1 8
8 0
1 1
ii Q 1
0 1
1 1
1 1
1 1
1 1
RECIPIENT ID 'CODE/NAME NRR LB3 LA ADM/LFMB NRR/DE/CEB 09-NRR/DHFS DEPY12" NRR/DHFS/LQB NRR/DL/ORAB NRR/DSI/ADRS NRR/DSI/CPB 11 NRR/DSI/ICSB 18 N
~
21 E,
04 RM/DDAMI/Ml8 COPIES LTTR ENCL' 0
1 0
1 1
1 1
1 1.
1 0
1 0
1 1
1 1>>
1 1
1 1
0 EXTERNAL: LPDR NSIC 03>>
06" 1.
1 1
1 NRC PDR PNL GRUELgR 02' 1
1 1
TOTAL'UMBER OF COPIES REQUIRED'" L'TTR 36 ENCL 28
r I
)/
g A
II,
)
r
'I f
V a
Arizona Nuclear Power Project P.O. BOX 52034
~
PHOENIX, ARIZONA85072-2034 ANPP-32303-EEVB/WFQ April 3, 1985 Director of Nuclear Reactor Regulation Mr. George W. Knighton, Chief Licensing Branch No.
3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.
C.
20555
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Units 1, 2,
and 3
Docket Nos.
STN 50-528(License NO.NPF-34)/529/530 Essential Spray Pond Corrosion Files 85-056-026 Dear Mr. Knightons On March 1,
1985 a
leaking weld in an eight inch diameter stainless steel pipe inside the PVNGS Unit 2 essential spray pond was identified.
Subsequent investigation by ANPP determined other leaking welds which appeared as pin hole size perforations through the weld area.
As a
- result, ANPP began an evaluation to determine the cause and scope of the problem and its impact on operation of PVNGS.
At the beginning of our evaluation during the week of March 11, you requested our participation in a
telephone conference call to provide you and appropriate NRC staff participants current information regarding this concern.
During the conference call NRC requested a
prompt report on the subject evaluating the safety impact on PVNGS.
Enclosed per your request is a
copy of our report and evaluation of the spray pond weld corrosion concern.
Please contact me if you have any questions.
Very truly yours, 8504050215 850403 PDR ADOCK 05000528 P
PDR E.
E.
Van Brunt, Jr.
Executive Vice President Project Director EEVB/WFQ/jdf Enclosure ccs E. A. Licitra w/enc R. P.
Zimmerman w/enc A. C. Gehr w/enc J.
B. Martin w/enc