N AC FORM SSS U. S NUCl.SAR REGULATORY COMMISSION P TTI t.lCEiNSEE EVCIMT REPORT CONTROL SLOCIKI I I I  !

QI (PLEASE PAINT OA TYPE ALl, A'EOUIRKD INPOAMATIONI 4

~FILIAL EIIIQ0 9 UCKNSKS COOK I

01- 001010101.0 LICSiu$ 4 EEIUMBER 0Q411 lS TS I III L;CL'4$4 TYPE IQ~Q l0 ST ~T $ 4 CCN'T RKPQAT LLLQS 40 4I 0 5 i 0 0 QOCXET NVMSSR i [ !QT 49 8 IO!4,Q 0 ll 2I I Q>

SV SNT OKSCRIPTION ANO PROSASL,S CO44SSOUSEHCSS QIO 0 I 2 Ourin normal o eration at 100K ow r I

inadIFertentl diluted leadin t I cated reactor ower increased over about 15 mini

~Q ls, l Tc also increased durin the transient reachin 542 5 the s d

~a>> l .imit is 542 f . Action er T.S.3.2.5.u(as taken and

~or  ! reduced. This is the first event of this t e.

~04 T 3 SYSTEM CA VS 4 CAVS S COMP, VALVE SUSCCOS CCMPONENTCQQK SVSCQQS 'VBCQOS 8

C QS COOK 1 4 9 ELLLie IFJS 10 II LEJQ IS IS IS WXQIS I9 mQ SSQUSNTI*l OCCUAAKiICS REPORT

~

REVISION'QQE LERIRO eVKNTYSAA A SPORT NO. TYPE ~ NO.

Qi; ~ EFEFEF

~BP TI TT 23 34 TS L~J Laic L3 3

laJ 4 'CH PUTUAK EJPEC. SNVTQCWN *T.ACNMSAT'IPPIO44 PRIME COMP.

l COMPONENT SE ~ ACTION SLJS LJS LJO CN PLANT MKTIIQO HQV AS 22 eg SVSMITTEO Lue LJO 41 POAM $ US. SVPPUKR I

43 IS LOcFS 44 MANUSACTUAKR 4T CALSS OKSCRIPTlON ANO CORRSCilVS ACTIONS Q2l o I ! Mhile addin makeu and d' 0

!relief valve V2173 Crosb st le JR-MR-S ailed returnin boric l uostream from the relief was normal T and later re aired.

.4

~i< S~E Q saCIIL' ~

~20 MKTIIOOQP

- ei POWER OTIIKR STATUS CISCOVERY QI SCOV KR Y 0 ESCA LATICN QS2 n>> ~EnTY T 4

$ . ATUS

'MES 3

C IO NTS.'IT I'3 IS 44

~AQSI 0 erator Observation 40

~SLe~io QP RELEASE AMOUNTOP ACTIVITYQSS LOCATION OP RELEASE Q2

~I!>> ~Z QSS ~ZQ24 NA 45 NA 40 I

T 3 IO II 44 PSRSONNK EXPOSURES NUMSER QSSCAIPTION 2 L00000'Q>>~ZLQE qlA

~

T 5 II I'3 IS P$1$ CNNSL INlURIK3 LBOOOIQ 40

$ $ QP CA OAMAQS,Q PAOLITY SS QESCRIPTIQN Q42 T 4

~ZQ42 3 'g PUBLIC:~0.

S NA NRC USE ONLY ISSUSO QESCRiPT:QN

~20 LN IQ~ NA 44 30 IO 39 NAMA OP PREPARER P. L. Pace (305) 552-3801 8102 18OI'P53.

REPORTABLE OCCURRENCE 335-80-.71 LICENSEE EVENT REPORT PAGE TWO ADDITIONAI CAUSE DESCRIPT IOfl The chargino pumps'; which take suction on the YCT, pump..bora'ted water

~

into the RCSfor boron concentration control and makeup. llhile blending boric acid and water to the VCT to slightly dilute the RCS and add make-up', a relief in the line to the blending valve failed. This returned the boric acic.'o the boric acid makeup f'ink instead of into the VCT.

This resulted in the dilution of the VCT and therefore the dilution of the RCZ.

The plant is designed to safely accomodate this transient but the event is potentially significant due to the misleading indication given. The relief valve is downstream from the boric acid flow element so the operators had indication of'a normal blend to the VCT. Due to the small amount of acid involved (a few gallons) and the large boric acid tank size (8,000 gallons), tank level did not respond with notice-able indication. Increasing power was the first indication of the transient and the cause was not readily apoarent. Since dilution via the VCT is a slow process, the transient had been in orogress for several minutes before there was any indication. An alternate boron injecticn path was used to reduce power.

The relief was disassembled and found to have a cut seat and a bent stem. Th seat was repaired and the stem replaced. The bent stem was the root cause of the dilution. How the stem became bent is unknown.

A review by Plant Operators of this LER and of the proper actions taken, will increase awareness of this problem and will help the operator to deal with similar events, should they occur in the future.

t f