ML17257A198

From kanterella
Jump to navigation Jump to search
Letter from NEI Regarding Hardened Containment Venting System (HCVS) Final Integrated Plan Template (EA-13-109), Revision 0, September 12, 2017
ML17257A198
Person / Time
Site: Nuclear Energy Institute
Issue date: 09/14/2017
From: Kraft S
Nuclear Energy Institute
To: Rajender Auluck
NRC/NRR/JLD/PSB
Auluck R, NRR/JLD, 415-1025
References
EA-13-109
Download: ML17257A198 (64)


Text

STEVEN P. KRAFT Senior Technical Advisor 1201 F Street, NW, Suite 1100 Washington, DC 20004 P: 202.739.8116 spk@nei.org nei.org September 14, 2017 Mr. Rajender Auluck Senior Project Manager Policy and Support Branch Japan Lessons-Learned Project Directorate Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Transmittal of Hardened Containment Venting System (HCVS) Final Integrated Plan Template (EA-13-109), Revision 0, September 12, 2017 Project Number: 689

Dear Mr. Auluck:

The Nuclear Energy Institute (NEI)1, on behalf of the nuclear industry, is pleased to submit to the U.S.

Nuclear Regulatory Commission (NRC) the Hardened Containment Venting System (HCVS) Final Integrated Plan Template (EA-13-109), Revision 0, September 12, 2017. This template will be used by NRC licensees in conjunction with NEI 13-02, Industry Guidance for Compliance with Order EA-13-109.

NRC Order EA-13-109 (issued June 6, 2013) modifies certain licenses with regard to reliable hardened containment vents capable of operation under severe accident conditions. We request that the NRC review and endorse the Hardened Containment Venting System (HCVS) Final Integrated Plan Template (EA 109), Revision 0.

1 The Nuclear Energy Institute (NEI) is the organization responsible for establishing unified industry policy on matters affecting the nuclear energy industry, including the regulatory aspects of generic operational and technical issues. NEI's members include all entities licensed to operate commercial nuclear power plants in the United States, nuclear plant designers, major architect/engineering firms, fuel cycle facilities, nuclear materials licensees, and other organizations and entities involved in the nuclear energy industry.

Mr. Rajender Auluck September 14, 2017 Page 2 Drafts of this template were presented and discussed at several NRC public meetings, most recently on August 17, 2017. If the NRC staff wishes to hold additional meetings to further discuss this or other topics related to licensee implementation of EA-13-109, please let us know.

If you have any questions or require additional information, please do not hesitate to contact me.

Sincerely, Steven P. Kraft Attachment

Final Integrated Plan

{Template}

HCVS Order EA-13-109 for

[Brunswick Steam Electric Plant (BSEP)]

[September 12, 2017]

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page ii

[September 12, 2017]

Instructions for Template Use

{Delete this page before submitting the FIP}

Black Text Used to indicate information that is generic in nature and expected to be the same for most if not all sites implementing the HCVS Order EA-13-109. Sites using this template should review the black text and confirm it is accurate and complete for their site, but should not change the text unless necessary to accurately describe site specific details.

[Green Text Enclosed in Square Brackets]

Used to indicate site specific details that are expected by be modified by each site using the template. Sites using this template should review the green text and modify as needed to accurately describe the site specific details. All green text should be changed to black text before submitting the FIP. Please note that the [Green Text] in the template is provided as examples based on the pilot prepared for Brunswick Steam Electric Plant.

{Red Text Enclosed in Brackets}

Used to indicate instructions for using the template at specific locations where such instruction is needed to provide clarification and direction for the use of the template.

These instructions should be deleted before submitting the FIP.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page iii

[September 12, 2017]

Table of Contents Section I: Introduction............................................................................................................................... 1 Section I.A: Summary of Compliance................................................................................................ 3 Section I.A.1: Summary of Phase 1 Compliance......................................................................... 3 Section I.A.2: Summary of Phase 2 Compliance......................................................................... 3 Section II: List of Acronyms...................................................................................................................... 5 Section III: Phase 1 Final Integrated Plan Details................................................................................. 7 Section III.A: HCVS Phase 1 Compliance Overview........................................................................ 7 Section III.A.1: Generic Letter 89-16 Vent System...................................................................... 7 Section III.A.2: EA-13-109 Hardened Containment Vent System (HCVS)............................... 8 Section III.B: HCVS Phase 1 Evaluation Against Requirements:................................................. 10

1.

HCVS Functional Requirements............................................................................................ 11

2.

HCVS Quality Standards:........................................................................................................ 25 Section IV: HCVS Phase 2 Final Integrated Plan............................................................................... 26 Section IV.A: The requirements of EA-13-109, Attachment 2, Section B for Phase 2............. 26

1.

HCVS Drywell Vent Functional Requirements..................................................................... 27

2.

Containment Venting Strategy Requirements..................................................................... 27 Section IV.B: HCVS Existing System............................................................................................... 28 Section IV.C: HCVS Phase 2 SAWA System and SAWM Strategy............................................ 28 Section IV.C.1: Detailed SAWA Flow Path Description............................................................. 28 Section IV.C.2: Severe Accident Assessment of Flow Path...................................................... 29 Section IV.C.3: Severe Accident Assessment of Safety-Relief Valves.................................... 29 Section IV.C.4: Available Freeboard Use..................................................................................... 30 Section IV.C.5: Upper range of wetwell level indication............................................................. 30 Section IV.C.6: Wetwell vent service time................................................................................... 30 Section IV.C.7: Strategy time line.................................................................................................. 30 Section IV.C.8: SAWA Flow Control............................................................................................. 31 Section IV.C.9: SAWA/SAWM Element Assessment................................................................. 31 Section IV.C.10: SAWA/SAWM Instrumentation........................................................................ 33 Section IV.C.11: SAWA/SAWM Severe Accident Considerations.......................................... 35 Section V: HCVS Programmatic Requirements.................................................................................. 37 Section V.A: HCVS Procedure Requirements................................................................................ 37 Section V.B: HCVS Out of Service Requirements......................................................................... 39 Section V.C: HCVS Training Requirements.................................................................................... 40

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page iv

[September 12, 2017]

Section V.D: Demonstration with other Post Fukushima Measures........................................... 41 Section VI: References........................................................................................................................... 42 : Phase 2 Freeboard diagram........................................................................................ 45 : One Line Diagram of HCVS Vent Path...................................................................... 46 : One Line Diagram of HCVS Electrical Power Supply - Unit 1................................ 47 a: One Line Diagram of HCVS Electrical Power Supply - Unit 2............................. 48 : One Line Diagram of SAWA Flow Path..................................................................... 49 : One Line Diagram of SAWA Electrical Power Supply............................................. 50 : Plant Layout Showing Operator Action Locations.................................................... 51 Table 1: List of HCVS Component, Control and Instrument Qualifications................................... 53 Table 2: Operator Actions Evaluation.................................................................................................. 56

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 1

[September 12, 2017]

Section I: Introduction In 1989, the NRC issued Generic Letter 89-16, Installation of a Hardened Wetwell Vent, (Reference 1) to all licensees of BWRs with Mark I containments to encourage licensees to voluntarily install a hardened wetwell vent. In response, licensees installed a hardened vent pipe from the wetwell to some point outside the secondary containment envelope (usually outside the reactor building). Some licensees also installed a hardened vent branch line from the drywell.

On March 19, 2013, the Nuclear Regulatory Commission (NRC) Commissioners directed the staff per Staff Requirements Memorandum (SRM) for SECY 0157, Consideration of Additional Requirements for Containment Venting Systems for Boiling Water Reactors with Mark I and Mark II Containments (References 2 and 3) to require licensees with Mark I and Mark II containments to "upgrade or replace the reliable hardened vents required by Order EA-12-050, Order to Modify Licenses with Regard to Reliable Hardened Containment Vents (Reference 4) with a containment venting system designed and installed to remain functional during severe accident conditions." In response, the NRC issued Order EA-13-109, Issuance of Order to Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accidents, June 6, 2013 (Reference 5). The Order (EA-13-109) requires that licensees of BWR facilities with Mark I and Mark II containment designs ensure that these facilities have a reliable hardened vent to remove decay heat from the containment, and to maintain control of containment pressure within acceptable limits following events that result in the loss of active containment heat removal capability while maintaining the capability to operate under severe accident (SA) conditions resulting from an Extended Loss of AC Power (ELAP).

[Insert plant name] is required by NRC Order EA-13-109 to have a reliable, severe accident capable hardened containment venting system (HCVS). Order EA-13-109 allows implementation of the HCVS Order in two phases.

Phase 1 upgraded the venting capabilities from the containment wetwell to provide reliable, severe accident capable hardened vent to assist in preventing core damage and, if necessary, to provide venting capability during severe accident conditions. [Insert plant name] achieved Phase 1 compliance on [insert date].

Phase 2 provided additional protections for severe accident conditions through the development of a reliable containment venting strategy that makes it unlikely that

[insert plant name] would need to vent from the containment drywell during severe accident conditions. [Insert plant name] achieved Phase 2 compliance on [insert date].

NEI developed guidance for complying with NRC Order EA-13-109 in NEI 13-02, Industry Guidance for Compliance with Order EA-13-109, BWR Mark I & II Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions,

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 2

[September 12, 2017]

Revision 0 (Reference 6) with significant interaction with the NRC and Licensees. NEI issued Revision 1 to NEI 13-02 in April 2015 (Reference 7) which contained guidance for compliance with both Phase 1 and Phase 2 of the order. NEI 13-02, Revision 1 also includes HCVS-Frequently Asked Questions (FAQs) 01 through 09 and reference to white papers (HCVS-WP-01 through 03 (References 8 through 10)). The NRC endorsed NEI 13-02 Revision 0 as an acceptable approach for complying with Order EA-13-109 through Interim Staff Guidance JLD-ISG-2013-02, Compliance with Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation under Severe Accident Conditions, issued in November 2013 (Reference 12) and JLD-ISG-2015-01, Compliance with Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation under Severe Accident Conditions issued in April 2015 (Reference 13) for NEI 13-02 Revision 1 with some clarifications and exceptions. NEI 13-02 Revision 1 provides an acceptable method of compliance for both Phases of Order EA-13-109.

In addition to the endorsed guidance in NEI 13-02, the NRC staff endorsed several other documents that provide guidance for specific areas. HCVS-FAQs 10 through 13 (References 14 through 17) were endorsed by the NRC after NEI 13-02 Revision 1 on October 8, 2015. NRC staff also endorsed four White Papers, HCVS-WP-01 through 04 (References 8 through 11), which cover broader or more complex topics than the FAQs.

As required by the order, [Insert plant name] submitted a phase 1 Overall Integrated Plan (OIP) in June of 2014 (Reference 18) and subsequently submitted a combined Phase 1 and 2 OIP in December 2015 (Reference 19). These OIPs followed the guidance NEI 13-02 Revision 0 and 1 respectively, Compliance with Order EA-13-109, Severe Accident Reliable Hardened Containment Vents. The NRC staff used the methods described in the ISGs to evaluate licensee compliance as presented in the Order EA 109 OIPs. While the Phase 1 and combined Phase 1 and 2 OIPs where written to different revisions of NEI 13-02, [Insert plant name] conform to NEI 13-02 Revision 1 for both Phases of Order EA-13-109.

The NRC performed a review of each OIP submittal and provided [Insert plant name]

with Interim Staff Evaluations (ISEs) (References 20 and 21) assessing the sites compliance methods. In the ISEs the NRC identified open items which the site needed to address before that phase of compliance was reached. Six month progress reports (References 22 through 28) were provided consistent with the requirements of Order EA-13-109. These status reports were used to close many of the ISE open items.

In addition, the site participated in NRC ISE Open Item audit calls where the information provided in the six month updates and on the E-Portal were used by the NRC staff to determine whether the ISE Open Item appeared to be addressed.

By submittal of this Final Integrated Plan [Insert plant name] has addressed all the elements of NRC Order EA-13-109 utilizing the endorsed guidance in NEI 13-02, Rev 1 and the related HCVS-FAQs and HCVS-WPs documents. In addition, the site has addressed the NRC Phase 1 and Phase 2 ISE Open Items as documented in previous six month updates or within the Phase 1 and 2 Compliance Letter for the first

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 3

[September 12, 2017]

compliance Unit (References 29).

Section III contains the [Insert plant name] Final Integrated Plan details for Phase 1 of the Order.Section IV contains the Final Integrated Plan details for Phase 2 of the Order.

Section V details the programmatic elements of compliance.

Section I.A: Summary of Compliance Section I.A.1: Summary of Phase 1 Compliance The plant venting actions for the EA-13-109, Phase 1, severe accident capable venting scenario can be summarized by the following:

The HCVS is initiated via manual action from the [{insert either} Main Control Room (MCR) {or other} Primary Operating Station (POS) that will be treated as the main operating location for this order] or Remote Operating Station (ROS) at the appropriate time based on procedural guidance in response to plant conditions from observed or derived symptoms.

The vent utilizes containment parameters of pressure and level from the MCR instrumentation to monitor effectiveness of the venting actions.

The vent operation is monitored by HCVS valve position, temperature and effluent radiation levels.

The HCVS motive force is monitored and has the capacity to operate for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with installed equipment. Replenishment of the motive force will be by use of portable equipment once the installed motive force is exhausted.

Venting actions are capable of being maintained for a sustained period of at least 7 days.

The operation of the HCVS is designed to minimize the reliance on operator actions in response to external hazards. The screened in external hazards for [BSEP {insert list of hazards} are seismic, external flooding, high winds, extreme high temperature, and extreme cold - ice only]. Initial operator actions are completed by plant personnel and include the capability for remote-manual initiation from the HCVS control station. contains a one-line diagram of the HCVS vent flowpath.

Section I.A.2: Summary of Phase 2 Compliance The Phase 2 actions can be summarized as follows:

Utilization of Severe Accident Water Addition (SAWA) to initially inject water into the Reactor Pressure Vessel (RPV).

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 4

[September 12, 2017]

Utilization of Severe Accident Water Management (SAWM) to control injection and Suppression Pool level to ensure the HCVS Phase 1 wetwell vent will remain functional for the removal of heat from the containment.

Heat can be removed from the containment for at least seven (7) days using the HCVS or until alternate means of heat removal are established that make it unlikely the drywell vent will be required for containment pressure control.

The SAWA and SAWM actions can be manually activated and controlled from areas that are accessible during severe accident conditions.

Parameters measured are Drywell pressure, Suppression Pool level, SAWA flowrate and the HCVS Phase 1 vent path parameters.

The locations of the SAWA equipment and controls, as well as ingress and egress paths have been evaluated for the expected severe accident conditions (temperature, humidity, radiation) for the Sustained Operating period. Equipment has been evaluated to remain operational throughout the Sustained Operating period. Personnel radiological exposure, temperature and humidity conditions for operation of SAWA equipment will not exceed the limits for ERO dose or plant safety guidelines for temperature and humidity.

{Include a statement of whether or not this is the same flow path as that reviewed or being reviewed for EA-12-049 compliance. If different, point to the calculation or analysis that determined the changes are acceptable}

The SAWA flow path is the same as the FLEX primary injection flow path with the modification that the hose run inside the RB was replaced with stainless steel piping. The flow path is from the units Condensate Storage Tanks (CST) through the FLEX pump including a SAWA flow indicator. The SAWA flow passes through the FLEX pump discharge hose, to a core bore at the Reactor Building (RB) outer wall where it is connected using quick connection hardware. Inside the RB the SAWA flow path is from the core bore, through a normally closed valve, through a stainless steel hard pipe, then through another isolation valve into the Reactor Water Cleanup system return line. This line connects to the RCIC injection line, which connects to the main Feedwater line and into the Reactor Pressure Vessel. Cross flow into other portions of the RWCU system is isolated by check valves and, in the case of a seismic event, closing one manual valve.

DW pressure and Suppression Pool level are monitored and flow rate is adjusted by use of the FLEX pump control valve at the CST. Communication is established between the MCR and the FLEX pump location. Attachment 4 contains a one-line diagram of the SAWA flowpath.

{Include a statement of whether or not the SAWA electrical loads are the same as that reviewed or being reviewed for EA-12-049 compliance. If different, point to the calculation or analysis that determined the changes are acceptable.}

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 5

[September 12, 2017]

The SAWA electrical loads are included in the FLEX DG loading calculation being reviewed for EA-12-049 compliance. The FLEX DGs are located east of the RB and are a significant distance and on the opposite side of the RB from the discharge of the HCVS on the west side of the RBs. See Attachment 6 for applicable locations. Refueling of the FLEX DG is accomplished from the EDG fuel oil tanks as described in the EA-12-049 FIP.

Evaluations for projected SA conditions (radiation / temperature) indicate that personnel can complete the initial and support activities without exceeding the ERO-allowable dose for equipment operation or site safety standards.

Electrical equipment and instrumentation is powered from the existing station batteries, and from AC distribution systems that are powered from the FLEX generator(s). The battery chargers are also powered from the FLEX generator(s) to maintain the battery capacities during the Sustained Operating period.

Section II: List of Acronyms

{Add plant specific acronyms with site specifics; ensure all acronyms used in the FIP are included.}

AC Alternating Current AOV Air Operated Valve BDBEE Beyond Design Basis External Event BSEP Brunswick Steam Electric Plant BWROG Boiling Water Reactor Owners Group CAC Containment Atmospheric Control System CAP Containment Accident Pressure CST Condensate Storage Tank DC Direct Current ECCS Emergency Core Cooling Systems ELAP Extended Loss of AC Power EOP Emergency Operating Procedure

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 6

[September 12, 2017]

EPG/SAG Emergency Procedure and Severe Accident Guidelines EPRI Electric Power Research Institute ERO Emergency Response Organization FAQ Frequently Asked Question FIP Final Integrated Plan FLEX Diverse & Flexible Coping Strategy FSB FLEX Storage Building GPM Gallons per minute HCVS Hardened Containment Vent System ISE Interim Staff Evaluation ISG Interim Staff Guidance JLD Japan Lessons Learned Project Directorate MAAP Modular Accident Analysis Program MCR Main Control Room N2 Nitrogen NEI Nuclear Energy Institute NPSH Net Positive Suction Head NRC Nuclear Regulatory Commission OIP Overall Integrated Plan PCPL Primary Containment Pressure Limit RCIC Reactor Core Isolation Cooling System RM Radiation Monitor ROS Remote Operating Station RPV Reactor Pressure Vessel

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 7

[September 12, 2017]

RWCU Reactor Water Cleanup SA Severe Accident SAMG Severe Accident Management Guidelines SAWA Severe Accident Water Addition SAWM Severe Accident Water Management SBGT Standby Gas Treatment System SFP Spent Fuel Pool SRV Safety-Relief Valve UFSAR Updated Final Safety Analysis Report VAC Voltage AC VDC Voltage DC WW Wetwell Section III: Phase 1 Final Integrated Plan DetailsSection III.A: HCVS Phase 1 Compliance Overview BSEP modified the existing hardened wetwell vent path installed in response to NRC Generic Letter 89-16 to comply with NRC Order EA-13-109.

Section III.A.1: Generic Letter 89-16 Vent System

{Describe Generic Letter 89-16 vent below or for Mark II state not required}

BSEP installed a hardened wetwell vent in response to NRC Generic Letter 89-16, under Plant Modifications PM-91-001 for Unit 1 and PM-92-073 for Unit 2. The description of the vent system below is common to both units. The hardened wetwell vent system allows venting of the wetwell by utilizing the wetwell purge exhaust line thru Penetration X220 and normally closed inboard purge exhaust valve CAC-V7.

Between valve CAC-V7 and the outboard purge exhaust valve CAC-V8, 8-inch vent line (75-8-152) and wetwell vent isolation valve CAC-V216 was installed (Ref. PI2 & PI8).

Downstream of isolation valve CAC-V216, line (75-12-154A), a Non-Safety Related, seismic line exits the Reactor Building on the West side at elevation 5 ft. into the rattlespace between the Reactor Building and the Turbine Building and, supported from the Reactor Building wall, runs along the exterior of the building. The vent line re-enters the Reactor Building at the refueling floor level, El. 117-4, then rises along the

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 8

[September 12, 2017]

West side where it exits the Reactor Building roof at El. 179-5. The vent line is equipped with a rupture disk (CAC-RD-001) with a burst pressure of 55 psig, just downstream of the isolation valve CAC-V216 to preclude inadvertent opening of the vent line in the event of a design basis event and another rupture disk (CAC-RD-002) with a burst pressure of 5 psig at its end to preclude entry of debris and precipitation. The 55 psig burst pressure for rupture disk CAC-RD-001 was selected as being above the maximum Loss of Coolant Accident containment pressure of 49 psig, yet below the containment design pressure of 62 psig. The existing wetwell vent system and components are designed for 70 psig at 316 ºF, corresponding to saturated steam conditions at the Primary Containment Pressure Limit (PCPL) of 70 psig. The vent line is equipped with a radiation monitor adjacent to the line for alerting the operators of a release through the vent line. The current radiation monitor (CAC-RM-80) is equipped with low range and high range detectors, to provide a range of 10-4 to 105C/cc of Xe-133. Wetwell vent valves CAC-V7 and CAC-V216 are equipped with keylock isolation signal override switches to allow bypass of the containment isolation signal to allow venting during a loss of containment heat removal event. CAC-V216 is additionally operated by a key-lock switch as another measure to prevent inadvertent operation.

Section III.A.2: EA-13-109 Hardened Containment Vent System (HCVS)

{Describe the final as-built Hardened Wetwell Vent System}

The EA-13-109 compliant HCVS system utilizes the GL-89-16 wetwell vent system.

The vent system is initiated, operated and monitored from the MCR using the switches described above. A ROS has been installed in a readily accessible location and provides a means to manually operate the wetwell vent. The controls available at the ROS are accessible and functional under a range of plant conditions, including severe accident conditions. The ROS location is in the RB 50 elevation, just inside the door to the Radwaste building Roof. Table 2 contains the evaluation of the acceptability of the ROS location with respect to severe accident conditions.

The final HCVS utilization does not contain any new electrical circuitry for bypassing isolation signals. The ROS opens the valves directly with compressed nitrogen so that no electrical signal overrides are needed.

The Main Control Room is the primary operating station for the HCVS. During an ELAP, electric power to operate the vent valves will be provided by batteries with a capacity to supply required loads for at least the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Before the batteries are depleted, the FLEX generator will supplement and recharge batteries to support operation of the vent valves. The ROS is designated as the alternate control location and method. Since the ROS does not require any electrical power to operate, the valve solenoids do not need any additional backup electrical power. Attachment 2 shows the HCVS vent flow path.

{Describe control and instrumentation available at each control location.} At the MCR location, the operators can operate the HCVS isolation valves if electrical power has

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 9

[September 12, 2017]

been restored, monitor HCVS vent valve position, drywell pressure, torus level, and backup nitrogen pressure. Also in the MCR area are the HCVS RM, vent pipe temperature, backup battery voltage, and backup vent valve position test jacks. The ROS consists of manual valves that directly port nitrogen to the actuators of the HCVS isolation valves. There is no instrumentation provided at the ROS. Table 1 contains a complete list of instruments available to the operators for operating and monitoring the HCVS.

The hardened vent radiation monitor uses a 24 VDC input power. The instruments to be powered for the 24-hour period are already powered by 24 VDC circuits. The following are the final electrical design highlights:

1. The valves limit switches can be read with a handheld meter at MCR panel XU-
53. Test jacks are provided on the front door so that the operators will not have to locate terminal points in the MCR panel, or even open the MCR panel door.

Determining valve position this way is only necessary if both FLEX generators fail to restore power to the valves circuits and the operators desire to verify valve positions directly. They may not need to verify the valve position if drywell pressure remains low indicating venting is occurring.

2. The RM is powered from the units Division 2 24/48 VDC battery (only one leg is used, resulting in a 24 VDC circuit) and is located in XU-54 where the 89-16 RM was mounted.
3. The 24 VDC battery voltage is indicated on XU-54.
4. The backup power to the required instruments can be transferred at MCR panel XU-54 (Unit 2) or XU-76 (Unit 1). The instruments receiving backup power are:
a. RNA-PT-5268 which indicates the status of the backup nitrogen system that supplies the valve actuators
b. CAC-LT-2601 which indicates the level in the torus so that operators can ensure the water level stays below the level of the vent pipe
c. CAC-PT-1230 which indicates drywell pressure so that operators can ensure that the vent is operating to maintain containment pressure low.
5. A test jack is provided on XU-54 for pipe temperature. It can be read using a hand held meter. This is redundant indication that venting is occurring and is a backup to the drywell pressure and valve position indications. and 3a contain(s) a one-line diagram of the HCVS electrical distribution system.

The wetwell vent up to, and including, the second containment isolation barrier is designed consistent with the design basis of the plant. These items include piping,

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 10

[September 12, 2017]

piping supports, containment isolation valves, containment isolation valve actuators and containment isolation valve position indication components. The hardened vent piping, between the wetwell and the Reactor Building roof, including boundary isolation valve CAC-V8 is designed to 70 psig at 316 ºF.

NEI 13-02 suggests a 350°F value for HCVS design temperature based on the highest Primary Containment Pressure Limit (PCPL) among the Mark I and II plants. Since 316°F corresponds to the saturation temperature for the BSEP PCPL of 70 psig, it will be retained as the pipe design temperature. Per NEI 13-02, it is acceptable to assume saturation conditions in containment (2.4.3.1) so that these design parameters are acceptable.

To prevent leakage of vented effluent to other parts of the Reactor Building or other systems (Standby Gas Treatment), boundary valves CAC-V8 and CAC-V172 must closed before wetwell venting. Valves CAC-V8 and CAC-V172 are the only boundary between the HCVS and the interfacing SBGT system. These valves are normally closed, fail closed, and are not required to change state in order to perform their safety related containment isolation function; therefore, they can be assumed to be closed when required. Valve CAC-V8 and CAC-V172 are part of the IST program and are leak tested in accordance with 10CFR50, Appendix J. This is acceptable for prevention of inadvertent cross-flow of vented fluids per HCVS-FAQ-05.

HCVS features to prevent inadvertent actuation include a key lock switch at the primary control station and locked closed valves at the ROS which is an acceptable method of preventing inadvertent actuation per NEI 13-02.

As required by EA-13-109, Section 1.2.11, the wetwell vent is designed to prevent air/oxygen backflow into the discharge piping to ensure the flammability limits of hydrogen, and other non-condensable gases, are not reached. BSEP design includes a check valve near the end of the vent pipe. Guidance for this design is contained in HCVS-WP-03. The relevant design calculations conclude that the check valve will preclude a flammable mixture from occurring in the vent pipe.

The HCVS radiation monitor with an ion chamber detector is qualified for the ELAP and external event conditions. In addition to the RM, a temperature element is installed on the vent line to allow the operators to monitor operation of the HCVS. Electrical and controls components are seismically qualified and include the ability to handle harsh environmental conditions (although they are not considered part of the site Environmental Qualification (EQ) program).

Section III.B: HCVS Phase 1 Evaluation Against Requirements:

The functional requirements of Phase 1 of NRC Order EA-13-109 are outlined below along with an evaluation of the [Insert plant name] response to maintain compliance with the Order and guidance from JLD-ISG-2015-01. Due to the difference between NEI 13-02, Revision 0 and Revision 1, only Revision 1 will be evaluated. Per

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 11

[September 12, 2017]

JLD-ISG-2015-01, this is acceptable as Revision 1 provides acceptable guidance for compliance with Phase 1 and Phase 2 of the Order.

1. HCVS Functional Requirements 1.1 The design of the HCVS shall consider the following performance objectives:

1.1.1 The HCVS shall be designed to minimize the reliance on operator actions.

Evaluation:

The operation of the HCVS was designed to minimize the reliance on operator actions in response to hazards identified in NEI 12-06, Diverse and Flexible Coping Strategies (FLEX) Implementation Guide (Reference 31), which are applicable to the plant site. Operator actions to initiate the HCVS vent path can be completed by plant personnel and include the capability for remote-manual initiation from the HCVS control station. A list of the remote manual actions performed by plant personnel to open the HCVS vent path is in the following table: {Insert the current table of actions. If applicable for lifting leads and/or installing jumpers used for defeating interlock(s), note whether those actions are exclusive to HCVS, or are part of EOP/SAMG guidance that has existed before EA-13-109 modifications.}

Table 3-1: HCVS Operator Actions Primary Action Primary Location/

Component Notes

1. Transfer HCVS electrical loads to 24 VDC Distribution Key-locked transfer switches located on XU-54 (Unit 2) or XU-76 (Unit 1).

Only performed if FLEX generators do not re-power these loads and only after the station batteries can no longer supply these loads.

2. Open Inboard Wetwell Purge Exhaust Valve 1/2-CAC-V7.

Control switch located in the MCR or via manual valve located at the ROS.

3. Open Hardened Wetwell Vent Valve 1/2-CAC-V216.

Key-locked control switch located in the MCR or via manual valve located at the ROS.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 12

[September 12, 2017]

Primary Action Primary Location/

Component Notes

4. Run hose to FLEX pneumatic makeup connection from FLEX air compressor staging location.

FLEX pneumatic makeup connections are located outside the RB in the vicinity of the HCVS vent pipe.

Action performed prior to venting start.

5. Replenish pneumatics with FLEX air compressor.

FLEX air compressor will be located in an area that is accessible to operators during a severe accident.

Action required to supplement the N2 backup system after a minimum of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

6. Re-power the 24/48VDC battery chargers for sustained operations (post-24 hours).

FLEX diesels are located in an area that meets the requirements of EA-12-049 and is accessible to operators during a severe accident.

Action required to provide power to HCVS equipment after a minimum of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Permanently installed electrical power and pneumatic supplies are available to support operation and monitoring of the HCVS for a minimum of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. No portable equipment larger than a hose need be moved in the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (Action 4 in above table).

After 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, available personnel will be able to connect supplemental electric power and pneumatic supplies for sustained operation of the HCVS for a minimum of 7 days. The FLEX generators and air compressors provide this motive force. In all likelihood, these actions will be completed in less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. However the HCVS can be operated for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> without any supplementation.

The above set of actions conform to the guidance in NEI 13-02 Revision 1 Section 4.2.6 for minimizing reliance on Operator actions and are acceptable for compliance with Order element A.1.1.1. These were identified in the OIP and subsequent NRC ISE.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 13

[September 12, 2017]

Table 3-2: Failure Evaluation Functional Failure Mode Failure Cause Alternate Action Failure with Alternate Action Impact on Containment Venting?

Fail to Vent (Open) on Demand Valves fail to open/close due to loss of normal AC power Transfer power to alternate from FLEX generator No Fail to Vent (Open) on Demand Valves fail to open/close due to loss of alternate AC power Open valves from ROS No Fail to Vent (Open) on Demand Valves fail to open/close due to loss of normal pneumatic air supply Open valves using Backup nitrogen system - no operator action required No Fail to Vent (Open) on Demand Valves fail to open/close due to loss of alternate pneumatic air supply (long term)

Align FLEX air compressor to Backup nitrogen system No 1.1.2 The HCVS shall be designed to minimize plant operators exposure to occupational hazards, such as extreme heat stress, while operating the HCVS system.

Evaluation:

Primary control of the HCVS is accomplished from the main control room.

Alternate control of the HCVS is accomplished from the ROS at the 50 elevation (second floor) of the reactor building. FLEX actions that will maintain the MCR and ROS habitable were implemented in response to NRC Order EA-12-049 (Reference 31). These include:

1. Restoring MCR ventilation via the FLEX DG. {If this is credited, include a statement confirming that this load was included in the FLEX generator loading analysis and room heatup analysis. If this is an added load for EA-13-109, point to the calculation or analysis that determined the changes are acceptable.} MCR ventilation was included as a load in the FLEX generator sizing calculations and is acceptable.
2. Opening MCR doors to the outside (if required)

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 14

[September 12, 2017]

3. Operating portable generators and fans to move outside air through the MCR (if required)
4. Opening doors and a roof hatch in the RB to establish natural circulation air flow in the RB.

Table 2 contains a thermal evaluation of all the operator actions that may be required to support HCVS operation. The relevant ventilation calculation(s) (Reference(s) 30 and 31) demonstrate that the final design meets the order requirements to minimize the plant operators exposure to occupational hazards.

1.1.3 The HCVS shall also be designed to minimize radiological consequences that would impede personnel actions needed for event response.

Evaluation:

Primary control of the HCVS is accomplished from the {main control room}. Under the postulated scenarios of order EA-13-109 the control room is adequately protected from excessive radiation dose and no further evaluation of its use is required. (Ref. HCVS-FAQ-06)

Alternate control of the HCVS is accomplished from the ROS. The ROS was evaluated for radiation effects due to a severe accident and determined to be acceptable. The ROS is located in a low dose are during normal operation. During and accident, the core material will be further from the ROS than during normal operation. In addition, there will be additional shielding from the two additional concrete floors after the core has re-located to the pedestal area. The additional distance and shielding combined with the short duration of actions required at the ROS show the ROS to be an acceptable location for alternate control.

Table 2 contains a radiological evaluation of the operator actions that may be required to support HCVS operation in a severe accident. There are no abnormal radiological conditions present for HCVS operation without core damage. The evaluation of radiological hazards demonstrates that the final design meets the order requirements to minimize the plant operators exposure to radiological hazards.

The HCVS vent is routed away from the MCR such that building structures provide shielding, thus per HCVS-FAQ-01 the MCR is the preferred control location. If venting operations create the potential for airborne contamination in the MCR, the ERO will provide personal protective equipment to minimize any operator exposure.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 15

[September 12, 2017]

1.1.4 The HCVS controls and indications shall be accessible and functional under a range of plant conditions, including severe accident conditions, extended loss of AC power, and inadequate containment cooling.

Evaluation: {If utilizing a primary or alternate control location other than the MCR, describe plants design features that meet this requirement. Items such as geometry, shielding by buildings, additional shielding, distance from the vent pipe, etc. There is likely an Open Item that responds to this element.}

Primary control of the HCVS is accomplished from the main control room.

Under the postulated scenarios of order EA-13-109 the control room is adequately protected from excessive radiation dose and no further evaluation of its use is required (HCVS-FAQ-06). {If the MCR is not the primary control, state the primary control location here.}

Alternate control of the HCVS is accomplished from the ROS [insert location]. The ROS [insert location] is in an area evaluated to be accessible before and during a severe accident.

{Select one of the two paragraphs below that is applicable to the plant.

The second option may be applicable for those plants (e.g., Isolation Condensers) that do not reject a significant amount of heat to the containment post ELAP}

For ELAP with injection, the HCVS wetwell vent will be opened to protect the containment from overpressure. The operator actions and timing of those actions to perform this function under ELAP conditions were evaluated as part of [insert plant name] response to NRC Order EA 049 as stated in Reference [X {plant FIP or SER}].

{or}

For ELAP with injection, HCVS containment venting is not required to protect containment from overpressure. Containment pressure was evaluated as part of [insert plant name] response to NRC Order EA 049 as stated in Reference [X {plant FIP or SER}].

Table 2 contains a thermal and radiological evaluation of all the operator actions at the MCR or alternate location that may be required to support HCVS operation during a severe accident. The relevant ventilation calculation(s) (Reference(s) 30 and 31) demonstrate that the final design meets the order requirements to minimize the plant operators exposure to occupational and radiological hazards.

Table 1 contains an evaluation of the controls and indications that are or may be required to operate the HCVS during a severe accident. The

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 16

[September 12, 2017]

evaluation demonstrates that the controls and indications are accessible and functional during a severe accident with a loss of AC power and inadequate containment cooling.

1.2 The HCVS shall include the following design features:

1.2.1 The HCVS shall have the capacity to vent the steam/energy equivalent of 1 percent of licensed /rated thermal power (unless a lower value is justified by analysis), and be able to maintain containment pressure below the primary containment design pressure.

Evaluation {Discuss methods used to size the vent. NRC staff will evaluate the method in the SE. (e.g., used RELAP to model compressible flow, assumed discharge of steam only, steaming rate determined using 1% decay heat and hfg, piping resistance factors taken from XX.}

Calculation {0FLEX-0035} contains the verification of 1% power flow capacity at design pressure (62 psig). This calculation models all the piping elbows, valves and other components using industry standard flow coefficients to determine an equivalent length of piping. Since the piping consists of 8 and 12 sections, both are modeled. The model is input to ARROW code which is an industry standard program for modeling compressible flow in piping. The code also looks for flow choking effects.

The minimum flow at design pressure to pass 1% RTP is 84,500 lbm/hr.

0FLEX-0035 verifies that the piping can pass greater than 1% flow.

Additional assumptions and modeling details are contained in 0FLEX-0035.

The decay heat absorbing capacity of the suppression pool and the selection of venting pressure were made such that the HCVS will have sufficient capacity to maintain containment pressure at or below the lower of the containment design pressure ({62} psig) or the PCPL ({70] psig).

This calculation of containment response is contained in {MAAP calculation BNP-MECH-FLEX-0002 } that was submitted in Reference 26

{insert reference where this open item was closed} and which shows that containment is maintained below the design pressure once the vent is opened, even if it is not opened until PCPL.

1.2.2 The HCVS shall discharge the effluent to a release point above main plant structures.

Evaluation

{Hatch: Plant specific setup for the plant stack to meet this requirement}

The wetwell vent exits the Primary Containment through the {describe the

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 17

[September 12, 2017]

vent pipe path} wetwell purge exhaust piping and associated inboard wetwell purge exhaust valve}. Between the inboard and outboard wetwell purge exhaust valves, the wetwell vent isolation valve is installed.

Downstream of the wetwell vent isolation valve, the vent piping exits the Reactor Building through the west wall and into the space between the Reactor Building and Turbine Building. The vent traverses up the exterior of the building and re-enters the Reactor Building through the metal siding on the refuel floor, then rises along the west side where it exits the Reactor Building through the roof. All effluents are exhausted above each units Reactor Building. This discharge point was extended approximately three feet above each units Reactor Building parapet wall such that the release point will vent away from emergency ventilation system intake and exhaust openings, main control room location, location of HCVS portable equipment, access routes required following an ELAP and BDBEE, and emergency response facilities. Part of the HCVS-FAQ-04 guidance is designed to ensure that vented fluids are not drawn immediately back into any emergency ventilation intakes. Such ventilation intakes should be below a level of the pipe by 1 foot for every 5 horizontal feet. The MCR emergency intake in the ELAP event is at the 49 ft. elevation which is approximately 130 feet below the HVCS pipe outlet. This intake is approximately 200 feet from the Unit 2 vent pipe (further than Unit 1),

which would require the intake to be approximately 40 feet below the vent pipe. Therefore, the vent pipe is appropriately placed relative to this air intake.

The vent pipe extends approximately 3 ft. above the parapet wall of the RB roof. This satisfies the guidance for height from HCVS-FAQ-04.

{Insert information about how the plant meets HCVS-WP-04, specifically addressing each of the 4 criteria items or plant specific analysis of protection.} EC 299559 attachment Z01R0 was provided for EA-12-049 compliance and contains an evaluation of vent pipe for protection from external events - {or} HCVS-WP-04 provides criteria that demonstrate robustness of the HCVS pipe. [Insert plant name] meets all the requirements of this white paper. This evaluation documents that the HCVS pipe is adequately protected from all external events and no further protection is required.

Plant evaluated the vent pipe robustness with respect to wind-borne missiles against the requirements contained in HCVS-WP-04. This evaluation demonstrated that the pipe was robust with respect to external missiles per HCVS-WP-04 in that:

1. For the portions of exposed piping below 30 feet above grade, {provide a description of how this portion of the pipe is protected or robust.}

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 18

[September 12, 2017]

2. The exposed piping greater than 30 feet above grade has the following characteristics:
a. The total vent pipe exposed area is 200 square feet which is less than the 300 square feet.
b. The pipe is made of schedule 40 stainless steel and is not plastic and the pipe components have no small tubing susceptible to missiles
c. There are no obvious sources of missiles located in the proximity of the exposed HCVS components.
3. [Insert plant name] maintains a large cutoff saw as part of the FLEX equipment. This saw is capable of cutting the vent pipe should it become damaged such that it restricts flow to an unacceptable level.
4. [Insert plant name] maintains severe weather preparedness procedures that would require the plant be shut down prior to the arrival of sustained hurricane force winds on site {OR} Hurricanes are not screened for BSEP.

Based on the above description of the vent pipe design, the [Insert plant name] HCVS vent pipe design meets the order requirement to be robust with respect to all external hazards including wind-borne missiles.

1.2.3 The HCVS shall include design features to minimize unintended cross flow of vented fluids within a unit and between units on the site.

Evaluation

{For multi-unit sites} The HCVS for Units 1 & 2 are fully independent of each other. Therefore, the status at each unit is independent of the status of the other unit.

{Hatch: Plant specific setup for the plant stack to meet this requirement.}

{Describe potential cross-flow paths and how they are isolated from the vented fluids.} The wetwell vent for each unit utilizes CAC system valves CAC-V7 and CAC-V216 for containment isolation. CAC system containment isolation valves CAC-V8 and CAC-V172 are the only functional boundary valves between the HCVS and the downstream SBGT system. These valves have a safety related function to maintain the containment pressure boundary during a design basis accident and are tested as required by 10CFR50, Appendix J. The containment isolation valves are AOVs and they are air-to-open and spring-to-shut. An SOV must be energized to allow the motive air to open the valve from the

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 19

[September 12, 2017]

MCR location. Although these valves are shared between the CAC and the HCVS, separate control circuits are provided to each valve.

Specifically, the CAC control circuit will be used during all design basis operating modes including all design basis transients and accidents. The downstream CAC isolation valves serve the function of isolating the HCVS flow path from the SBGT. These valves are tested, and will continue to be tested, for leakage under 10CFR50 Appendix J as part of the containment boundary in accordance with HCVS-FAQ-05.

Based on the above description, the [Insert plant name] design meets the requirements to minimize unintended cross-flow of vented fluids within a unit and between units on site.

1.2.4 The HCVS shall be designed to be manually operated during sustained operations from a control panel located in the main control room or a remote but readily accessible location.

Evaluation The existing wetwell vent will allow initiating and then operating and monitoring from a control panel located in the MCR. {If another location other than the MCR, describe its location and explain how it is readily accessible. Utilize Table 2 which contains a list and evaluation of the HCVS required actions. Attachment 6 shows the location of major HCVS actions. These evaluations demonstrate that the design meets the requirement to be manually operated from a readily accessible location during sustained operation.}

1.2.5 The HCVS shall be capable of manual operation (e.g., reach-rod with hand wheel or manual operation of pneumatic supply valves from a shielded location), which is accessible to plant operators during sustained operations.

Evaluation To meet the requirement for an alternate means of operation, {describe manual operation method} a readily accessible alternate location, called the ROS was added. The ROS contains manually operated valves that supply pneumatics to the HCVS flow path valve actuators so that these valves may be opened without power to the valve actuator solenoids and regardless of any containment isolation signals that may be actuated.

This provides a diverse method of valve operation improving system reliability.

{Describe location and accessibility of this method} The location for the ROS is in the southeast corner of the RB 50-0 for Unit 1, and the

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 20

[September 12, 2017]

northeast corner of the RB 50-0 elevation for Unit 2. The ROS is located within the RB in an area shielded from the HCVS vent pipe by intervening structures, with a direct path to the MCR. Refer to the sketch provided in for the HCVS site layout. The controls available at the ROS location are accessible and functional under a range of plant conditions, including severe accident conditions with due consideration to source term and dose impact on operator exposure, extended loss of AC power (ELAP), inadequate containment cooling, and loss of reactor building ventilation. Table 1 contains an evaluation of all the required controls and instruments that are required for severe accident response and demonstrates that all these controls and instruments will be functional during a loss of AC power and severe accident. Table 2 contains a thermal and radiological evaluation of all the operator actions that may be required to support HCVS operation during a loss of AC power and severe accident and demonstrates that these actions will be possible without undue hazard to the operators. Attachment 6 contains a site layout showing the location of these HCVS actions.

1.2.6 The HCVS shall be capable of operating with dedicated and permanently installed equipment for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following the loss of normal power or loss of normal pneumatic supplies to air operated components during an extended loss of AC power.

Evaluation HCVS-WP-01 contains clarification on the definition of dedicated and permanently installed with respect to the order. In summary, it is acceptable to use plant equipment that is used for other functions, but it is not acceptable to credit portable equipment that must be moved and connected for the first 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period of the ELAP.

The FLEX generators will start and load, thus there will be no need to use other power sources for HCVS wetwell venting components during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. However, this order element does not allow crediting the FLEX generators for HCVS wetwell venting components until after 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Therefore, backup electrical power required for operation of HCVS components in the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> will come from an existing Division 2 24/48 VDC battery. These batteries are permanently installed in the Control Building ground floor where they are protected from screened in hazards, and have sufficient capacity to provide this power without recharging. Calculation BNP-E-6.125 demonstrated that the 24/48VDC battery capacity is sufficient to supply HCVS wetwell venting components for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. At 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, FLEX generators can be credited to repower the station instrument buses and/or the battery charger to recharge the 24/48VDC batteries, gas control during recharging and room temperature control is per the response to order EA-12-049. Calculation 31116-CALC-

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 21

[September 12, 2017]

E-001 included the 24/48VDC battery chargers in the FLEX DG loading calculation, so there is no additional load on the FLEX DG and they are capable of carrying HCVS wetwell venting components electrical loads.

24/48VDC battery voltage status will be indicated on panel XU-54 so that operators will be able to monitor the status of the 24/48VDC batteries. and 3a contains a diagram of the HCVS electrical distribution system.

Pneumatic power for the HCVS valve actuators is normally provided by the non-interruptible instrument air system (for the Reactor Building) and the pneumatic nitrogen system (for the Drywell) with backup nitrogen provided from the nitrogen backup system. Following an ELAP event, and the loss of non-interruptible instrument air and pneumatic nitrogen, the nitrogen backup system automatically provides operating pneumatics to the SRV accumulators and hardened wetwell vent valves. Therefore, for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> post-ELAP initiation, pneumatic force will be supplied from the existing nitrogen backup system bottle racks located on the EL. 50-0 of the Reactor Building. Calculation 0RNA-0001 demonstrated that these installed bottles have the capacity to supply the required motive force to those HCVS valves needed to maintain flow through the HCVS effluent piping for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> without replenishment.

Backup nitrogen pressure indication will be provided with HCVS power for use if its normal supply is not restored by the FLEX generators.

1.2.7 The HCVS shall include a means to prevent inadvertent actuation.

Evaluation Emergency operating procedures provide clear guidance that the HCVS is not to be used to defeat containment integrity during any design basis transients and accidents. In addition, the HCVS was designed to provide features to prevent inadvertent actuation due to equipment malfunction or operator error. Also, these protections are designed such that any credited containment accident pressure (CAP) that would provide net positive suction head to the emergency core cooling system (ECCS) pumps will be available (inclusive of a design basis loss-of-coolant accident). However, the ECCS pumps will not have normal power available because of the ELAP.

The containment isolation valves must be open to permit vent flow. The physical features that prevent inadvertent actuation are the key lock switch for CAC-V216 at the primary control station and locked closed valves at the ROS. These design features meet the requirement to prevent inadvertent actuation of HCVS.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 22

[September 12, 2017]

1.2.8 The HCVS shall include a means to monitor the status of the vent system (e.g., valve position indication) from the control panel required by 1.2.4. The monitoring system shall be designed for sustained operation during an extended loss of AC power.

Evaluation The HCVS includes indications for HCVS valve position, vent pipe temperature and effluent radiation levels in the MCR, as well as information on the status of supporting systems which are 24 VDC battery voltage and division 2 backup nitrogen pressure.

This monitoring instrumentation provides the indication from the MCR per Requirement 1.2.4. In the event that the FLEX DGs do not energize the emergency buses, the wetwell HCVS and required containment instrumentation will be supplied by the Division 2 24/48VDC batteries and designed for sustained operation during an ELAP event using the FLEX equipment.

HCVS instrumentation performance (e.g., accuracy and range) need not exceed that of similar plant installed equipment. Additionally, radiation monitoring instrumentation accuracy and range is sufficient to confirm flow of radionuclides through the HCVS.

The HCVS instruments, including valve position indication, vent pipe temperature, radiation monitoring, and support system monitoring, are seismically qualified as indicated on Table 1 and they include the ability to handle harsh environmental conditions (although they may not be considered part of the site Environmental Qualification (EQ) program).

1.2.9 The HCVS shall include a means to monitor the effluent discharge for radioactivity that may be released from operation of the HCVS. The monitoring system shall provide indication from the control panel required by 1.2.4 and shall be designed for sustained operation during an extended loss of AC power.

Evaluation The HCVS radiation monitoring system consists of an ion chamber detector coupled to a process and control module. The process and control module is mounted in MCR panel XU-54 in the CB 49 elevation.

The RM detector is fully qualified for the expected environment at the vent pipe during accident conditions, and the process and control module is qualified for the mild environment in the CB 49. Both components are qualified for the seismic requirements. Table 1 includes a description and qualification information on the radiation monitor.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 23

[September 12, 2017]

1.2.10 The HCVS shall be designed to withstand and remain functional during severe accident conditions, including containment pressure, temperature, and radiation while venting steam, hydrogen, and other non-condensable gases and aerosols. The design is not required to exceed the current capability of the limiting containment components.

Evaluation The wetwell vent up to, and including, the second containment isolation valve is designed consistent with the design basis of the plant. These items include piping, piping supports, containment isolation valves, containment isolation valve actuators and containment isolation valve position indication components.

The existing hardened vent piping, between the wetwell and the Reactor Building roof, including {list interfacing valves} valve CAC-V8 is designed to 70 psig at 316 ºF. Wetwell vent piping and components installed downstream of the containment isolation boundary are designed for beyond design basis conditions.

HCVS piping and components have been analyzed and shown to perform under severe accident conditions using the guidance provided in HCVS-FAQ-08 and HCVS-WP-02. {Point to the document or open item response that contains this evaluation, such as not in the Reactor Building} contains the response to ISE open item 14 regarding the evaluation of HCVS components for severe accident conditions.

Refer to EA-13-109, requirement 1.2.11 for a discussion on designing for combustible gas.

1.2.11 The HCVS shall be designed and operated to ensure the flammability limits of gases passing through the system are not reached; otherwise, the system shall be designed to withstand dynamic loading resulting from hydrogen deflagration and detonation.

Evaluation

{Check valve response} In order to prevent a detonable mixture from developing in the pipe, a check valve is installed near the top of the pipe in accordance with HCVS-WP-03. This valve will open on venting, but will close to prevent air from migrating back into the pipe after a period of venting. The check valve is installed and tested to ensure that it limits back-leakage to preclude a detonable mixture from occurring in the case venting is stopped prior to the establishment of alternate reliable containment heat removal. The use of a check valve meets the requirement to ensure the flammability limits of gases passing through the

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 24

[September 12, 2017]

vent pipe will not be reached.

{Purge response} In order to prevent a detonable mixture from developing in the pipe, a purge system is installed to purge hydrogen from the pipe with argon after a period of venting and to purge oxygen from the pipe prior to resuming venting. This system is { describe operation of the system with regard to lineup, manual or automatic, purge gas, etc.} The use of a purge system meets the requirement to ensure the flammability limits of gases passing through the vent pipe will not be reached.

1.2.12 The HCVS shall be designed to minimize the potential for hydrogen gas migration and ingress into the reactor building or other buildings.

Evaluation The response under Order element 1.2.3 explains how the potential for hydrogen migration into other systems, the reactor building or other buildings is minimized.

1.2.13 The HCVS shall include features and provisions for the operation, testing, inspection and maintenance adequate to ensure that reliable function and capability are maintained.

Evaluation:

As endorsed in the ISG, sections 5.4 and 6.2 of NEI 13-02 provide acceptable method(s) for satisfying the requirements for operation, testing, inspection, and maintenance of the HCVS.

Primary and secondary containment required leakage testing is covered under existing design basis testing programs. The HCVS outboard the containment boundary shall be tested to ensure that vent flow is released to the outside with minimal leakage, if any, through the interfacing boundaries with other systems or units.

[Insert plant name] has implemented the following operation, testing and inspection requirements for the HCVS to ensure reliable operation of the system. These are from NEI 13-02, Table 6.1. The implementing modification packages contain these as well as additional testing required for post-modification testing.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 25

[September 12, 2017]

Table 3-3: Testing and Inspection Requirements Description Frequency Cycle the HCVS valves1 and the interfacing system valves not used to maintain containment integrity during operations.

Once per every2 operating cycle.

Cycle the HCVS check valves not used to maintain containment integrity during unit operations.3 Once per every other4 operating cycle.

Perform visual inspections and a walk down of HCVS components Once per operating cycle Functionally test the HCVS radiation monitors.

Once per operating cycle Leak test the HCVS.

(1) Prior to first declaring the system functional; (2) Once every three operating cycles thereafter; and (3) After restoration of any breach of system boundary within the buildings Validate the HCVS operating procedures by conducting an open/close test of the HCVS control logic from its control panel (primary and alternate) and ensuring that all interfacing system boundary5 valves move to their proper (intended) positions.

Once per every other operating cycle

2.

HCVS Quality Standards:

2.1. The HCVS vent path up to and including the second containment isolation barrier shall be designed consistent with the design basis of the plant. Items in this path include piping, piping supports, containment isolation valves, containment isolation valve actuators, and containment isolation valve position indication components.

1 Not required for HCVS check valves.

2 After two consecutive successful performances, the test frequency may be reduced to a maximum of once per every other operating cycle.

3 Not required if integrity of check function (open and closed) is demonstrated by other plant testing requirements.

4 After two consecutive successful performances, the test frequency may be reduced by one operating cycle to a maximum of once per every fourth operating cycle.

5 Interfacing system boundary valves that are normally closed and fail closed under ELAP conditions (loss of power and/or air) do not require control function testing under this section. Performing existing plant design basis function testing or system operation that reposition the valve(s) to the HCVS required position will meet this requirement without the need for additional testing.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 26

[September 12, 2017]

Evaluation:

{For existing vents} The HCVS upstream of and including the second containment isolation valve (CAC-V216) and penetrations are not being modified for order compliance so that they continue to be designed consistent with the design basis of primary containment including pressure, temperature, radiation, and seismic loads.

{For new vents} The HCVS penetration and containment isolation valves are designed and installed consistent with the design basis of primary containment including pressure, temperature, radiation, and seismic loads.

2.2. All other HCVS components shall be designed for reliable and rugged performance that is capable of ensuring HCVS functionality following a seismic event. These items include electrical power supply, valve actuator pneumatic supply, and instrumentation (local and remote) components.

Evaluation:

The HCVS components downstream of the outboard containment isolation valve and components that interface with the HCVS are routed in seismically qualified structures or supported from seismically qualified structure(s).

The HCVS downstream of the outboard containment isolation valve, including piping and supports, electrical power supply, valve actuator pneumatic supply, and instrumentation (local and remote) components, have been designed and analyzed to conform to the requirements consistent with the applicable design codes for the plant and to ensure functionality following a design basis earthquake. This includes environmental qualification consistent with expected conditions at the equipment location.

Table 1 contains a list of components, controls and instruments required to operate HCVS, their qualification and evaluation against the expected conditions. All instruments are fully qualified for the expected seismic conditions so that they will remain functional following a seismic event.

Section IV: HCVS Phase 2 Final Integrated Plan Section IV.A: The requirements of EA-13-109, Attachment 2, Section B for Phase 2

Licensees with BWRs Mark 1 and Mark II containments shall either:

(1) Design and install a HCVS, using a vent path from the containment drywell, that meets the requirements in section B.1 below, or (2) Develop and implement a reliable containment venting strategy that makes it

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 27

[September 12, 2017]

unlikely that a licensee would need to vent from the containment drywell before alternate reliable containment heat removal and pressure control is reestablished and meets the requirements in Section B.2 below.

1.

HCVS Drywell Vent Functional Requirements 1.1 The drywell venting system shall be designed to vent the containment atmosphere (including steam, hydrogen, non-condensable gases, aerosols, and fission products), and control containment pressure within acceptable limits during severe accident conditions.

1.2 The same functional requirements (reflecting accident conditions in the drywell),

quality requirements, and programmatic requirements defined in Section A of this Attachment for the wetwell venting system shall also apply to the drywell venting system.

2.

Containment Venting Strategy Requirements Licensees choosing to develop and implement a reliable containment venting strategy that does not require a reliable, severe accident capable drywell venting system shall meet the following requirements:

2.1 The strategy making it unlikely that a licensee would need to vent from the containment drywell during severe accident conditions shall be part of the overall accident management plan for Mark I and Mark II containments.

2.2 The licensee shall provide supporting documentation demonstrating that containment failure as a result of overpressure can be prevented without a drywell vent during severe accident conditions.

2.3 Implementation of the strategy shall include licensees preparing the necessary procedures, defining and fulfilling functional requirements for installed or portable equipment (e.g., pumps and valves), and installing needed instrumentation.

Because the order contains just three requirements for the containment venting strategy, the compliance elements are in NEI 13-02, Revision 1. NEI 13-02, Revision 1, endorsed by NRC in JLD-ISG-2015-01, provides the guidance for the containment venting strategy (B.2) of the order. NEI 13-02, Revision 1, provides SAWA in conjunction with Severe Accident Water Management (SAWM), which is designed to maintain the wetwell vent in service until alternate reliable containment heat removal and pressure control are established, as the means for compliance with part B of the order.

[Insert plant name] has implemented Containment Venting Strategy (B.2), as the compliance method for Phase 2 of the Order and conforms to the associated guidance in NEI 13-02 Revision 1 for this compliance method.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 28

[September 12, 2017]

Section IV.B: HCVS Existing System There previously was neither a hardened drywell vent nor a strategy at [Insert plant name] that complied with Phase 2 of the order.

Section IV.C: HCVS Phase 2 SAWA System and SAWM Strategy The HCVS Phase 2 SAWA system and SAWM strategy utilize the FLEX mitigation equipment and strategies to the extent practical. This approach is reasonable because the external hazards and the event initiator (ELAP) are the same for both FLEX mitigation strategies and HCVS. For SAWA, it is assumed that the initial FLEX response actions are unsuccessful in providing core cooling such that core damage contributes to significant radiological impacts that may impede the deployment, connection and use of FLEX equipment. These radiological impacts, including dose from containment and HCVS vent line shine were evaluated and modifications made as necessary to mitigate the radiological impacts such that the actions needed to implement SAWA and SAWM are feasible in the timeframes necessary to protect the containment from overpressure related failure. To the extent practical, the SAWA equipment, connection points, deployment locations and access routes are the same as the FLEX primary strategies so that a Unit that initially implements FLEX actions that later degrades to severe accident conditions can readily transition between FLEX and SAWA strategies. This approach further enhances the feasibility of SAWA under a variety of event sequences including timing.

[Insert plant name] has implemented the containment venting strategy utilizing SAWA and SAWM. The SAWA system consists of a FLEX (SAWA) pump injecting into the Reactor Pressure Vessel (RPV) and SAWM consists of flow control at the FLEX (SAWA) pump along with instrumentation and procedures to ensure that the wetwell vent is not submerged (SAWM). Procedures have been issued to implement this strategy including revision 3 to the Severe Accident Management Guidelines (SAMG). This strategy has been shown via Modular Accident Analysis Program (MAAP) analysis to protect containment without requiring a drywell vent for at least seven days which is the guidance from NEI 13-02 for the period of sustained operation.

Section IV.C.1: Detailed SAWA Flow Path Description

{State whether this is the same as the FLEX injection path, or has been modified for SAWA. If different, describe the differences and point to the calculation or analysis that confirms the changes are acceptable} The SAWA flow path is the same as the FLEX primary injection path except that the hose run inside the RB was replaced with stainless steel pipe. The SAWA system, shown on Attachment 4, consists of a FLEX pump injecting into the Reactor Pressure Vessel (RPV) and SAWM consists of flow control at the FLEX pump along with wetwell level indication to ensure that the wetwell vent is not submerged (SAWM). The SAWA injection path, starts at the Condensate Storage Tank (CST), goes to the FLEX

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 29

[September 12, 2017]

pump via suction hoses, goes through the FLEX pump to a flexible discharge hose, then to a core bore at the Reactor Building (RB). The hoses and pumps are stored in the FLEX Storage Building (FSB) which is protected from all hazards. From the core bore inside the RB, the FLEX path runs via stainless steel pipe to a connection at the Reactor Water Cleanup (RWCU) system. This RWCU connection ties to the Reactor Core Isolation Cooling (RCIC) system, then to the Reactor Feedwater System, then to the Reactor Pressure Vessel (RPV). BWROG generic assessment, BWROG-TP-15-008, provides the principles of Severe Accident Water Addition to ensure protection of containment. This SAWA injection path is qualified for the all the screened in hazards (Section III) in addition to severe accident conditions.

Section IV.C.2: Severe Accident Assessment of Flow Path

{Clearly state if the FLEX(SAWA) pump deployment time is enveloped by the deployment time for FLEX or to explain the differences in expected deployment time or indicate if the deployment was timed validated as part of the EA-13-109 response.}

The actions inside the RB where there could be a high radiation field due to a severe accident will be to open valves at the core bore and the RWCU connections just above the containment hatch and accessed from the 23 level of the RB via a fixed ladder, and potentially (only for a seismic event) close one valve on the 80 level. The action to open (and possibly close) valves inside the RB can be performed before the dose is unacceptable, under the worst-case scenario within the first hour, after the loss of RPV injection. This time was validated as part of the Time Sensitive Action validation for EA-13-109. Procedure 0EOP-FSG-16 directs early accomplishment of actions that must be done early in the severe accident event where there is a loss of All AC power and a loss of all high-pressure injection to the core. In this event, core damage is not expected for at least one hour so that there will be no excessive radiation levels or heat related concerns in the RB when the valves are operated. The other SAWA actions all take place outside the RB (or inside the RB at a safe location) at the MCR, CST, RB outer wall, FSB, and the deployment pathways. Since these locations are outside the RB, they are shielded from the severe accident radiation by the thick concrete walls of the RB. Once SAWA is initiated, the operators will monitor the response of containment from the MCR to determine that venting and SAWA are operating satisfactorily, maintaining containment pressure low to avoid containment failure. Stable or slowly rising trend in wetwell level with SAWA at the minimum flow rate indicates water on the drywell floor up to the vent pipe or downcomer openings. After some period of time, as decay heat levels decrease, the operators will be able to reduce SAWA flow to keep the core debris cool while avoiding overfill the torus to the point where the wetwell vent is submerged.

Section IV.C.3: Severe Accident Assessment of Safety-Relief Valves

[Insert plant name] has methods available to extend the operational capability of

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 30

[September 12, 2017]

manual pressure control using SRVs as provided in the plant specific order EA 049 submittal. Assessment of manual SRV pressure control capability for use of SAWA during the Order defined accident is unnecessary because RPV depressurization is directed by the EPGs in all cases prior to entry into the SAGs.

Section IV.C.4: Available Freeboard Use

{Utilize response to Phase 2 Open Item} The freeboard between -2.5 and 6 elevation in the wetwell provides approximately 536,700 gallons of water volume before the level instrument would be off scale high {or} water level reaches the bottom of the vent pipe. BWROG generic assessment BWROG-TP-15-011, provides the principles of Severe Accident Water Management to preserve the wetwell vent for a minimum of seven days. After containment parameters are stabilized with SAWA flow, SAWA flow will be reduced to a point where containment pressure will remain low while wetwell level is stable or very slowly rising. As shown in calculation BNP-MECH-FLEX-0005, the wetwell level will not reach the wetwell vent for at least seven days. A diagram of the available freeboard is shown on Attachment 1.

Section IV.C.5: Upper range of wetwell level indication

{Utilize information from Phase 2 OIP}The upper range of wetwell level indication provided for SAWA/SAWM is +6 feet elevation. This defines the upper limit of wetwell volume that will preserve the wetwell vent function as shown in Attachment

1.

Section IV.C.6: Wetwell vent service time BSEP calculation BNP-MECH-FLEX-0005 {OR} Reference 27 in NEI 13-02, Revision 1 and BWROG-TP-15-011, demonstrate(s) that throttling SAWA flow after containment parameters have stabilized, in conjunction with venting containment through the wetwell vent will result in a stable or slowly rising wetwell level. The references demonstrate that, for the scenario analyzed, wetwell level will remain below the wetwell vent pipe for greater than the seven days of sustained operation allowing significant time for restoration of alternate containment pressure control and heat removal.

Section IV.C.7: Strategy time line

{Define procedure guidance and validated timelines} The overall accident management plan for [Insert Plant Name] is developed from the BWR Owners Group Emergency Procedure Guidelines and Severe Accident Guidelines (EPG/SAG). As such, the SAWA/SAWM implementing procedures are integrated into the [Insert Plant Name] SAMGs. In particular, EPG/SAG Revision 3, when implemented with Emergency Procedures Committee Generic Issue 1314, allows throttling of SAWA in order to protect containment while maintaining the wetwell vent in service. The SAMG flow charts direct use of the hardened vent as well as

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 31

[September 12, 2017]

SAWA/SAWM when the appropriate plant conditions have been reached.

Using NEI 12-06 Appendix E {OR} NEI letter from Nicholas X. Pappas, Senior Project Manager of NEI to Industry Administrative Points of Contact, Validation Document for FLEX Strategies, dated July 18, 2014 [Insert Plant Name] has validated that the SAWA pump can be deployed and commence injection in less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. The studies referenced in NEI 13-02 demonstrated that establishing flow within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> will protect containment. The initial SAWA flow rate will be at least 300 gpm. After a period of time, estimated to be about 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, in which the maximum flow rate is maintained, the SAWA flow will be reduced. The reduction in flow rate and the timing of the reduction will be based on stabilization of the containment parameters of drywell pressure and wetwell level.

BNP-MECH-FLEX-005 {OR} NEI 13-02 generic analysis per NEI 13-02 Reference 27 demonstrated that, SAWA flow could be reduced to 100 gpm after four hours of initial SAWA flow rate and containment would be protected. At some point wetwell level will begin to rise indicating that the SAWA flow is greater than the steaming rate due to containment heat load such that flow can be reduced. While this is expected to be 4-6 hours, no time is specified in the procedures because the SAMGs are symptom based guidelines.

Section IV.C.8: SAWA Flow Control

[Insert Plant Name] will accomplish SAWA flow control by the use of throttle valves on the SAWA pumps. The operators at the SAWA pump will be in communication with the MCR via radios or runners and the exact time to throttle flow is not critical since there is a large margin between normal wetwell level and the level at which the wetwell vent will be submerged. The communications capabilities that will be used for communication between the MCR and the SAWA flow control location are the same as that evaluated and found acceptable for FLEX strategies. The communications capabilities have been tested to ensure functionality at the SAWA flow control and monitoring locations. {Reference Phase 2 Open Item Closure}

Section IV.C.9: SAWA/SAWM Element Assessment Section IV.C.9.1: SAWA Pump

[Insert Plant Name] uses three portable diesel-driven fire pumps for FLEX and SAWA. Two pumps are capable of 3000 gpm and one 1500 gpm at the pressures required for RPV injection during an ELAP. Each of these pumps has been shown to be capable of supplying the required flow rate to the RPV and the SFP for FLEX and for SAWA scenarios. The pumps are stored in the FSB where they are protected from all screened-in hazards and are rugged, over the road, trailer-mounted units, and therefore will be available to function after a seismic event.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 32

[September 12, 2017]

Section IV.C.9.2: SAWA analysis of flow rates and timing

{MAAP or generic}

{Generic - select the generic option that applies to your plant:} Plant SAWA flow is 500 gpm which is the amount assumed in NEI 13-02 Section 4.1.1.2.1 {OR} XXX gpm which is the site-specific RCIC design flow rate {OR} XXX gpm which is the site-specific flow rate when the sites rated thermal power is compared to the reference power level of NEI 13-02. The initial SAWA flow will be injecting to the RPV within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of the loss of injection. The reference power level is 3514 MWth, equivalent to the reference plant rated thermal power level used in NUREG-1935, State of the Art Reactor Consequence Analysis (SOARCA). NUREG 1935 is Reference 9 of NEI 13-02 Revision 1.

{OR}

{Site-specific calculation or analysis should be provided for review on the ePortal.}

BNP-MECH-FLEX-0005 assumes a SAWA flow of 300 gpm starting 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after the loss of injection and demonstrates that containment is protected at this initial flow rate by comparing it to the results using 500 gpm. The results are virtually indistinguishable with respect to containment pressure therefore proving that this flow rate prevents containment failure by over pressurization as required by the order.

Section IV.C.9.3: SAWA Pump Hydraulic Analysis Calculation 0FLEX-0035 analyzed the FLEX pumps and the lineup for RPV injection that would be used for SAWA. This calculation showed that the pumps have adequate capacity to meet the SAWA flow rate required to protect containment. {This calculation should be provided for review on the ePortal.}

Section IV.C.9.4: SAWA Method of backflow prevention The BSEP SAWA flow path goes through a series of check valves in the RWCU and Feedwater systems. The Feedwater backflow prevention valves are also Primary Containment Isolation Valves (PCIVs) whose integrity of check function (open and closed) is demonstrated by other plant testing requirements such that additional testing per NEI 13-02 Revision 1 Section 6.2 is not required for these valves per NEI 13-02 Revision 1 Table 6-1 Note 3. Thus backflow is prevented by check valves in the SAWA flow path inside the RB.

Section IV.C.9.5: SAWA Water Source

{Describe the initial and long-term source of water for SAWA including makeup, if any.}

The initial source of water for SAWA is the CST which can provide approximately

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 33

[September 12, 2017]

52 hours6.018519e-4 days <br />0.0144 hours <br />8.597884e-5 weeks <br />1.9786e-5 months <br /> of water injection without makeup based on the FLEX analysis. Before this initial supply of water is depleted, the N+1 FLEX pump or the NSRC-supplied pump will be deployed to re-fill the CST from the discharge canal. This long-term strategy of water supply was qualified for order EA-12-049 response and is available during a severe accident. Therefore there will be sufficient water for injection to protect containment during the period of sustained operation.

Section IV.C.9.6: SAWA/SAWM Motive Force Section IV.C.9.6.1: SAWA Pump Power Source The SAWA pumps are stored in the FSB where they are protected from all screened-in hazards. The SAWA pumps are commercial fire pumps rated for long-term outdoor use in emergency scenarios. The pumps are diesel-driven by an engine mounted on the skid with the pump. The pumps will be refueled by the FLEX refueling equipment that has been qualified for long-term refueling operations per EA-12-049. The action to refuel the SAWA pumps was evaluated under severe accident conditions in Table 2, and demonstrated to be acceptable.

Since the pumps are stored in a protected structure(s), are qualified for the environment in which they will be used, and will be refueled by a qualified refueling strategy, they will perform their function to maintain SAWA flow needed to protect primary containment per EA-13-109.

Section IV.C.9.6.2: DG loading calculation for SAWA/SAWM equipment

{Describe battery calculations (if any) and place on the ePortal.} Table 1 shows the electrical power source for the SAWA/SAWM instruments. For the instruments powered by the 24/48VDC battery, calculation BNP-E-6.125 demonstrates that they can provide power until the FLEX generator restores power to the battery charger.

{Describe FLEX Generator loading calculations and place on the ePortal.} The FLEX load on the FLEX DG per EA-12-049 was evaluated in calculation 31116-CALC-E-001. This calculation demonstrated 367 kW of margin to full load. The additional loads on the FLEX DGs for SAWA and SAWM consist of {Note: describe any other components that may need power for SAWA/SAWM such as MOVs that are re-powered by the FLEX generator} the torus level instrument and the drywell pressure instrument which are powered from the division 2 24/48VDC battery via its battery charger. These instrument loops draw a maximum of 20 milliamps so that the load they add to the 500 KW FLEX DG is insignificant. The FLEX generator was qualified to carry the rest of the FLEX loads as part of Order EA-12-049 compliance.

Section IV.C.10: SAWA/SAWM Instrumentation

1) {List the specific instruments credited for SAWA.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 34

[September 12, 2017]

2) Describe the instruments used to monitor SAWA pump flow.
3) Qualifications of instrumentation (temperature/radiation/seismic).
4) Describe the means to provide power (e.g., skid mounted diesel engine/alternator, batteries or small portable AC generators) to these instruments for the Sustained Operation period.
5) Describe how containment pressure and wetwell level instrumentation will be repowered through the Sustained Operation period.}

Section IV.C.10.1: SAWA/SAWM instruments Table 1 contains a listing of all the instruments needed for SAWA and SAWM implementation. This table also contains the expected environmental parameters for each instrument, its qualifications, and its power supply for sustained operation.

Section IV.C.10.2: Describe SAWA instruments and guidance The drywell pressure and wetwell level instruments, used to monitor the condition of containment, are pressure and differential pressure detectors that are safety-related and qualified for post-accident use. These instruments are referenced in Severe Accident Guidelines for control of SAWA flow to maintain the wetwell vent in service while maintaining containment protection. These instruments are powered by batteries for at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and will be re-powered by FLEX generator systems for the sustained operating period. {State whether or not these instruments were included in the FLEX generator loading calculation reviewed for EA-12-049. If different, point to the calculation or analysis that determined the changes are acceptable.} These instruments are on buses included in the FLEX generator loading calculations for EA-12-049. Note that other indications of these parameters may be available depending on the exact scenario.

The SAWA flow meter is a paddle-wheel flow meter mounted in the piping on the pumps skid and powered by the pumps electrical system.

No containment temperature instrumentation is required for compliance with HCVS Phase 2. However, most FLEX electrical strategies repower other containment instruments that include drywell temperature, which may provide information for the operations staff to evaluate plant conditions under a severe accident and to provide confirmation for adjusting SAWA flow rates. SAMG strategies will evaluate and use drywell temperature indication if available consistent with the symptom based approach. NEI 13-02 Revision 1 Section C.8.3 discusses installed drywell temperature indication.

Section IV.C.10.3: Qualification of SAWA/SAWM instruments The drywell pressure and wetwell level instruments are pressure and differential

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 35

[September 12, 2017]

pressure detectors that are safety-related and qualified for post-accident use. {Non RG-1.97} The expected integrated dose to the instruments during the period of sustained operation is less than their qualification dose, and they are located in areas that will experience temperatures and humidity less than their qualified values. Table 1 demonstrates that these instruments are qualified for the expected conditions during a loss of AC power and severe accident {OR for RG-1.97} These instruments are qualified per RG-1.97 Revision 2 (Reference 32) which is the

[Insert Plant Name] committed version per UFSAR Section 1, Table 1-6 as post-accident instruments and are therefore qualified for EA-13-109 events.

The SAWA flow meter is rated for continuous use under the expected ambient conditions and so will be available for the entire period of sustained operation.

Furthermore, since the pump is deployed outside the RB, and on the opposite of the RB from the vent pipe, there is no concern for any effects of radiation exposure to the flow instrument. {Or describe how it is shielded and/or protected from external hazards if that is the case.}

Section IV.C.10.4: Instrument Power Supply through Sustained Operation

[Insert Plant Name] FLEX strategies will restore the containment instruments, containment pressure and wetwell level, necessary to successfully implement SAWA. The strategy will be to use the FLEX generator to re-power battery chargers before the batteries supplying the instruments are depleted. Since the FLEX generators are refueled per FLEX strategies for a sustained period of operation, the instruments will be powered for the sustained operating period.

Section IV.C.11: SAWA/SAWM Severe Accident Considerations

{Discuss if the thermal and radiological impacts on the installed or portable equipment and instrumentation would affect the functionality of these components or operators performing necessary actions for the SAWA/SAWM strategy. Place the evaluation or calculation on the ePortal.}

Section IV.C.11.1: Severe Accident Effect on SAWA Pump and Flowpath Since the SAWA pump is stored in the FSB and will be operated from outside the RB, on the opposite side of the RB from the vent pipe, there will be no issues with radiation dose rates at the SAWA pump control location and there will be no significant dose to the SAWA pump.

{For pipe runs} Inside the RB the SAWA flow path consists of stainless steel pipe which will remain unaffected by the radiation or elevated temperatures inside the RB. {Or for hose runs} Inside the RB the SAWA flow path consists of piping that will either be unaffected by the radiation dose and hoses that will be run only in locations that are shielded from significant radiation dose or that have been evaluated for the integrated dose effects over the period of Sustained Operation.

These hoses are qualified for the temperatures expected in the areas they will be

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 36

[September 12, 2017]

run. Therefore, the SAWA flow path will not be affected by radiation or temperature effects due to a severe accident.

{Sites that use hose inside the Reactor Building that is not shielded from severe accident dose rates should evaluate the hoses for acceptable performance in the dose fields expected and for the period of Sustained Operation. HCVS-OGP-008 provides a sample evaluation and methodology for this evaluation.}

Section IV.C.11.2: Severe Accident Effect on SAWA/SAWM instruments The SAWA/SAWM instruments are described in section IV.C.9.3, that section provides severe accident effectsSection IV.C.11.3: Severe Accident Effect on personnel actions

{Provide a high-level summary of actions} Section IV.C.2 describes the RB actions within the first 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. The actions including access routes outside the Reactor Building that will be performed after the first use of the vent during severe accident conditions (assumed to be 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> per HCVS-FAQ-12) are located such that they are either shielded from direct exposure to the vent line or are a significant distance from the vent line so that expected dose is maintained below the ERO exposure guidelines.

As part of the response to Order EA-12-049, [Insert Plant Name] performed GOTHIC calculations of the temperature response of the Reactor and Control Buildings during the ELAP event. Since, in the severe accident, the core materials are contained inside the primary containment, the temperature response of the RB and CB is driven by the loss of ventilation and ambient conditions and therefore will not change. Thus, the FLEX GOTHIC calculations are acceptable for severe accident use.

Table 2 provides a list of SAWA/SAWM operator actions as well as an evaluation of each for suitability during a severe accident. Attachment 6 shows the approximate locations of the actions.

After the SAWA pipe is aligned inside the RB, the operators can control SAWA/SAWM as well as observe the necessary instruments from outside the RB.

The thick concrete RB walls (below 117 level) as well as the distance to the core materials mean that there is no radiological concern with any actions outside the RB. Therefore, all SAWA controls and indications are accessible during severe accident conditions.

The SAWA pump and monitoring equipment can all be operated from the MCR or from outside the RB at ground level. The [Insert Plant Name] FLEX response ensures that the SAWA pump, FLEX air compressors, FLEX generators and other equipment can all be run for a sustained period by refueling. All the refueling locations are located in shielded or protected areas so that there is no radiation

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 37

[September 12, 2017]

hazard from core material during a severe accident. The monitoring instrumentation includes SAWA flow at the pump, and wetwell level and containment pressure in the MCR.

Section V: HCVS Programmatic RequirementsSection V.A: HCVS Procedure Requirements Licensees shall develop, implement, and maintain procedures necessary for the safe operation of the HCVS. Procedures shall be established for system operations when normal and backup power is available, and during an extended loss of AC power.

Evaluation:

Procedures have been established for system operations when normal and backup power is available, and during ELAP conditions. The implementing design change documents contain instructions for modifying the HCVS specific procedures.

The HCVS and SAWA procedures have been developed and implemented following BSEPs process for initiating and/or revising procedures and contain the following details:

appropriate conditions and criteria for use of the system when and how to place the system in operation, the location of system components, instrumentation available, normal and backup power supplies, directions for sustained operation, including the storage location of portable equipment, training on operating the portable equipment, and testing portable equipment

{If a CAP plant add} since [Insert Plant Name] relies on Containment Accident Pressure (CAP) to achieve net positive suction head (NPSH) for the Emergency Core Cooling System (ECCS) pumps, the procedures need to include precautions that use of the vent may impact NPSH (CAP) available to the ECCS pumps.

[Insert plant name] has implemented the BWROG Emergency Procedures Committee Issue 1314 that implements the Severe Accident Water

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 38

[September 12, 2017]

Management (SAWM) strategy in the Severe Accident Management Guidelines (SAMGs). The following general cautions, priorities and methods have been evaluated for plant specific applicability and incorporated as appropriate into the plant specific SAMGs using administrative procedures for EPG/SAG change control process and implementation. SAMGs are symptom based guidelines and therefore address a wide variety of possible plant conditions and capabilities. While these changes are intended to accommodate those specific conditions assumed in Order EA-13-109, the changes were made in a way that maintains the use of SAMGs in a symptom based mode while at the same time addressing those conditions that may exist under extended loss of AC power (ELAP) conditions with significant core damage including ex-vessel core debris.

Actual language that is incorporated into site SAMGs {Use site specific SAMG text for Cautions, Priorities and Methods added when implementing EPC Issue 1314}

Cautions Addressing the possible plant response associated with adding water to hot core debris and the resulting pressurization of the primary containment by rapid steam generation.

Addressing the plant impact that raising suppression pool water level above the elevation of the suppression chamber vent opening elevation will flood the suppression chamber vent path.

Priorities - With significant core damage and RPB breach, SAMGs prioritize the preservation of primary containment integrity while limiting radioactivity releases as follows:

Core debris in the primary containment is stabilized by water addition (SAWA).

Primary containment pressure is controlled below the Primary Containment Pressure Limit (Wetwell venting)

Water addition is managed to preserve the Mark I/II suppression chamber vent paths, thereby retaining the benefits of suppression pool scrubbing and minimizing the likelihood of radioactivity and hydrogen release into the secondary containment (SAWM)

Methods - Identify systems and capabilities to add water to the RPV or drywell, with the following generic guidance:

Use controlled injection if possible

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 39

[September 12, 2017]

Inject into the RPV if possible Maintain injection from external sources of water as low as possible to preserve the suppression chamber vent capability Section V.B: HCVS Out of Service Requirements Provisions for out-of-service requirements of the HCVS and compensatory measures have been added to PLP-01.4 so that it is with the FLEX out-of-service program {or - select the appropriate option} included in procedure [Insert procedure number].

Programmatic controls have been implemented to document and control the following:

NOTE: Out of service times and required actions noted below are for HCVS and SAWA functions. Equipment that also supports a FLEX function that is found to be non-functional must also be addressed using the out of service times and actions in accordance with the FLEX program.

The provisions for out-of-service requirements for HCVS and SAWA functionality are applicable in Modes 1, 2, and 3 per NEI 13-02, 6.3.

If for up to 90 consecutive days, the primary or alternate means of HCVS operation are non-functional, no compensatory actions are necessary.

If up for to 30 days, the primary and alternate means of HCVS operation or SAWA are non-functional, no compensatory actions are necessary.

If the out of service times projected to exceed 30 or 90 days as described above, the following actions will be performed through the corrective action system determine:

o The cause(s) of the non-functionality, o The actions to be taken and the schedule for restoring the system to functional status and prevent recurrence, o Initiate action to implement appropriate compensatory actions, and o Restore full HCVS functionality at the earliest opportunity not to exceed one full operating cycle.

The HCVS system is functional when piping, valves, instrumentation and controls including motive force necessary to support system operation are available. Since the system is designed to allow a primary control and monitoring or alternate valve control by Order criteria 1.2.4 or 1.2.5, allowing for a longer out of service time with

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 40

[September 12, 2017]

either of the functional capabilities maintained is justified. A shorter length of time when both primary control and monitoring and alternate valve control are unavailable is needed to restore system functionality in a timely manner while at the same time allowing for component repair or replacement in a time frame consistent with most high priority maintenance scheduling and repair programs, not to exceed 30 days unless compensatory actions are established per NEI 13-02 Section 6.3.1.3.3.

SAWA is functional when piping, valves, motive force, instrumentation and controls necessary to support system operation are functional.

The system functionality basis is for coping with beyond design basis events and therefore plant shutdown to address non-functional conditions is not warranted.

However, such conditions should be addressed by the corrective action program and compensatory actions to address the non-functional condition should be established. These compensatory actions may include alternative containment venting strategies or other strategies needed to reduce the likelihood of loss of fission product cladding integrity during design basis and beyond design basis events even though the severe accident capability of the vent system is degraded or non-functional. Compensatory actions may include actions to reduce the likelihood of needing the vent but may not provide redundant vent capability.

Applicability for allowed out of service time for HCVS and SAWA for system functional requirements is limited to startup, power operation and hot shutdown conditions when primary containment is required to be operable and containment integrity may be challenged by decay heat generation.

Section V.C: HCVS Training Requirements Licensee shall train appropriate personnel in the use of the HCVS. The training curricula shall include system operations when normal and backup power is available, and during an extended loss of AC power.

Evaluation:

Personnel expected to perform direct execution of the HCVS have received necessary training in the use of plant procedures for system operations when normal and backup power is available and during ELAP conditions. The training will be refreshed on a periodic basis and as any changes occur to the HCVS. The personnel trained and the frequency of training was determined using a systematic analysis of the tasks to be performed using the Systems Approach to Training (SAT) process.

In addition, per NEI 12-06, any non-trained personnel on-site will be available to supplement trained personnel.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 41

[September 12, 2017]

Section V.D: Demonstration with other Post Fukushima Measures

[Insert plant name] will demonstrate use of the HCVS and SAWA systems in drills, tabletops or exercises as follows:

1. Hardened containment vent operation on normal power sources (no ELAP)
2. During FLEX demonstrations (as required by EA-12-049: Hardened containment vent operation on backup power and from primary or alternate locations during conditions of ELAP/loss of UHS with no core damage.)

System use is for containment heat removal AND containment pressure control.

3. HCVS operation on backup power and from primary or alternate location during conditions of ELAP/loss of UHS with core damage. System use is for containment heat removal AND containment pressure control with potential for combustible gases.

Evaluation NOTE:

Items 1 and 2 above are not applicable to SAWA. Item 2 is not applicable because [insert plant name] credits the [insert reason, e.g.,

Isolation Condenser] for containment heat removal and the HCVS is not needed to support FLEX strategies.

The use of the HCVS and SAWA capabilities will be demonstrated during drills, tabletops or exercises consistent with NEI 13-06 and on a frequency consistent with 10 CFR 50.155(e)(4). [Insert plant name] will perform the first drill demonstrating at least one of the above capabilities by [insert date] which is within four years of the first unit compliance with Phase 2 of Order EA-13-109.

Subsequent drills, tabletops or exercises will be performed to demonstrate the capabilities of different elements of Items 1, 2 and/or 3 above that is applicable to

[insert plant name] in subsequent eight year intervals.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 42

[September 12, 2017]

Section VI: References Number Rev Title Location6

1. GL-89-16 0

Installation of a Hardened Wetwell Vent (Generic Letter 89-16), dated September 1, 1989.

ML031140220

2. SECY-12-0157 0

Consideration of Additional Requirements for Containment Venting Systems for Boiling Water Reactors with Mark I and Mark II Containments ML12345A030

3. SRM-SECY 0157 0

Staff Requirements - SECY-12-0157 -

Consideration of Additional Requirements for Containment Venting Systems for Boiling Water Reactors with Mark I and Mark II Containments ML13078A017

4. EA-12-050 0

Order to Modify Licenses with Regard to Reliable Hardened Containment Vents ML12054A694

5. EA-13-109 0

Order to Modify Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions ML13143A321

6. NEI 13-02 0

Industry Guidance for Compliance with Order EA-13-109, BWR Mark I & II Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions ML13316A853

7. NEI 13-027 1

Industry Guidance for Compliance with Order EA-13-109, BWR Mark I & II Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions ML15113B318

8. HCVS-WP-01 0

Hardened Containment Vent System Dedicated and Permanently Installed Motive Force, Revision 0, April 14, 2014 ML14120A295 ML14126A374

9. HCVS-WP-02 0

Sequences for HCVS Design and Method for Determining Radiological Dose from HCVS Piping, Revision 0, October 23, 2014 ML14358A038 ML14358A040

10. HCVS-WP-03 1

Hydrogen/Carbon Monoxide Control Measures Revision 1, October 2014 ML14302A066 ML15040A038

11. HCVS-WP-04 0

Missile Evaluation for HCVS Components 30 Feet Above Grade ML15244A923 ML15240A072 6 Where two ADAMS accession numbers are listed, the first is the reference document and the second is the NRC endorsement of that document.

7 NEI 13-02 Revision 1 Appendix J contains HCVS-FAQ-01 through HCVS-FAQ-09.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 43

[September 12, 2017]

Number Rev Title Location6

12. JLD-ISG-2013-02 0

Compliance with Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation under Severe Accident Conditions ML13304B836

13. JLD-ISG-2015-01 0

Compliance with Order EA-13-109, Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation under Severe Accident Conditions ML15104A118

14. HCVS-FAQ-10 1

Severe Accident Multiple Unit Response ML15273A141 ML15271A148

15. HCVS-FAQ-11 0

Plant Response During a Severe Accident ML15273A141 ML15271A148

16. HCVS-FAQ-12 0

Radiological Evaluations on Plant Actions Prior to HCVS Initial Use ML15273A141 ML15271A148

17. HCVS-FAQ-13 0

Severe Accident Venting Actions Validation ML15273A141 ML15271A148

18. Phase 1 OIP 0

HCVS Phase 1 Overall Integrated Plan (OIP)

ML14191A687

19. Combined OIP 0

Combined HCVS Phase 1 and 2 Overall Integrated Plan (OIP)

ML16020A064

20. Phase 1 ISE 0

HCVS Phase 1 Interim Staff Evaluation (ISE)

ML15049A266

21. Phase 2 ISE 0

HCVS Phase 2 Interim Staff Evaluation (ISE)

ML16223A725

22. 1st Update 0

First Six Month Update ML14364A029

23. 2nd Update 0

Second Six Month Update ML15196A035

24. 3rd Update 0

Third Six Month Update ML16020A064

25. 4th Update 0

Fourth Six Month Update ML16190A111

26. 5th Update 0

Fifth Six Month Update ML16365A007

27. 6th Update 0

Sixth Six Month Update ML17171A383

28. 7th Update 0

Seventh Six Month Update

[Accession No]

29. Compliance Letter 0

HCVS Phase 1 and Phase 2 compliance letter

[Accession No]

30. RB FLEX Heat-up Calc.

0 BNP-MECH-FLEX-0001 N/A

31. CB FLEX Room Heat-up Calc.

0 RWA-L-1312-003 N/A

32. NEI 12-06 0

Diverse and Flexible Coping Strategies (FLEX) Implementation Guide ML12221A205

33. EA-12-049 0

Issuance of Order to Modify Licenses With Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, dated March 12, 2012.

ML12054A735

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 44

[September 12, 2017]

Number Rev Title Location6

34. RG 1.97 3

Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Conditions During and Following an Accident ML003740282

35. TR-1026539 0

EPRI Investigation of Strategies for Mitigating Radiological Releases in Severe Accidents BWR, Mark I and Mark II Studies, October 2012 N/A

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 45

[September 12, 2017] : Phase 2 Freeboard diagram

{Use figure from OIP with updates as necessary}

Normal WW level ~-2.25 Spillover Freeboard height +~8.5, ~536,700 Additional freeboard height ~2 -

48,900 gal.

Drywell floor - 0.5 Vent pipe centerline elevation 77. 20 pipe El. 6, range of instrument

-10 elevation WW level LI-2601. -10 to +6 WW level increases approximately 0.24/hr at 300 gpm SAWA flowrate, assuming no boil off

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 46

[September 12, 2017] : One Line Diagram of HCVS Vent Path

{Use figure from OIP with updates as necessary}

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 47

[September 12, 2017]

{Use figure from OIP with updates as necessary}

One Line Diagram of HCVS Electrical Power Supply - Unit 1

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 48

[September 12, 2017] a: One Line Diagram of HCVS Electrical Power Supply - Unit 2

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 49

[September 12, 2017] : One Line Diagram of SAWA Flow Path

{Use figure from OIP with updates as necessary}

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 50

[September 12, 2017] : One Line Diagram of SAWA Electrical Power Supply N/A for BSEP

{Use figure from FLEX FIP or HCVS OIP with updates as necessary}

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 51

[September 12, 2017] : Plant Layout Showing Operator Action Locations

{Use figure similar to FLEX FIP or OIP or HCVS OIP with updates as necessary. Show action locations for both inside (if applicable) and outside the plant. If multiple figures are needed to show all locations, label as

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 52

[September 12, 2017]

Attachments 6A, 6B, etc.} If necessary

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 53

[September 12, 2017]

Table 1: List of HCVS Component, Control and Instrument Qualifications Component Name Equipment ID Range Location Local Accident Temp Local Accident Humidity Local Radiation Level Qualification8 Qualification Temp Qualification Humidity Qualification Radiation Power Supply Wetwell Vent Instruments and Components HCVS effluent temperature sensor (read with handheld meter in the MCR) 2-CAC-TE-7993 0-700°F 117' RB Floor, on 12" pipe 173°F 100%

Use 1' TID of 9.13E+05 Rad IEEE 344-1975 0-700°F No electronics, not susceptible 3.00E+08 None required HCVS effluent temperature sensor panel jack (read with a handheld meter) 2-CAC-TE-7993 N/A MCR 122°F 91%

    • CB N/A - insensitive N/A - insensitive N/A - insensitive N/A - insensitive Batteries in the handheld meter
  • 24/48VDC battery voltage meter 2-XU-54-VM 0-30 VDC MCR 122F 91%

N/A 24/48 VDC Battery Limit Switch test jacks (limit switches are qualified as PCIV components per existing design basis)

N/A N/A MCR 122°F 91%

  • Power transfer switches 2-CAC-CS-7984 2-CAC-CS-7985 2-CAC-CS-7987 2-CAC-CS-7988 2-RNA-CS-7986 N/A MCR 122°F 91%

N/A N/A 24/48VDC battery 2-24B-2-24VDC-BAT 1-22B-2-24VDC-BAT N/A CB 23' Battery Room B 120°F 91%

N/A Self for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, then FLEX generator powers charger Wetwell Vent line rad. Detector 1/2-CAC-RD-2B 1E-03 to 1E+06 Rad/hr 117' RB Floor 173°F 100%

TID at 1' 9.13E+05 Rad/Hr IEEE-323-1974, IEEE 344-1975 350°F 100%

2.00E+08 Rad/Hr 24/48 VDC battery bus 8 See UFSAR Appendix 7B Section B.2 for qualification code of record IEEE-323-1974 and IEEE-344-1975. Where later code years are referenced, this was reconciled in the design process.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 54

[September 12, 2017]

Component Name Equipment ID Range Location Local Accident Temp Local Accident Humidity Local Radiation Level Qualification8 Qualification Temp Qualification Humidity Qualification Radiation Power Supply Wetwell vent radiation monitor/

processor 1/2-CAC-RM-1000 1E-03 TO 1E+06 Rad/hr MCR 122°F 91%

N/A 24/48 VDC battery bus

  • Pneumatic valves CAC-V5061 and V5062 N/A RB -17 CS SW Room 132°F 100%

Use 1' TID of 2.54E+06 Rad/Hr for 20" pipe IEEE-344-1975 356°F No electronics, not susceptible 1.50E+08 Rad/Hr Nitrogen backup bottles for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, then FLEX air compressor

  • ROS valves CAC-V5058 CAC-V5059 CAC-V5060 N/A U-2 RB 50' NE 121°F 100%

Low dose area The location of the ROS can be considered a mild environment (i.e.,

low dose area and remains at a mild temperature). The valves are considered seismically robust per AD-EG-ALL-1125 and are therefore qualified for seismic response.

150°F No electronics, not susceptible N/A Manual

  • Div. II N2 Backup supply pressure meter and module 1/2-RNA-PT-5268 0-150 psig MCR 122°F 91%
  • Div. II N2 Backup supply pressure sensor and transmitter 1/2-RNA-PT-5268 0-150 psig 50' RB West 122°F/

119°F 100%

Use 1' TID of 9.13E+05 Rad/Hr, but this is outside the 6' thick PC

concrete, so should be much lower IEEE 323-1974 &

1983, IEEE 344-1975 148.8°F 100 8.36E+06 Rad/Hr 24/48 VDC battery bus

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 55

[September 12, 2017]

Component Name Equipment ID Range Location Local Accident Temp Local Accident Humidity Local Radiation Level Qualification8 Qualification Temp Qualification Humidity Qualification Radiation Power Supply SAWA/SAWM Instruments Drywell pressure sensor/

transmitter 1/2-CAC-PT-1230 0-60 psig 80' RB West 117°F

{or}

NA 100%

{or}

NA Use 1' TID of 9.13E5, but this is outside the 6' thick PC

concrete, so should be much lower IEEE 323-1974, IEEE 344-1975 148.8°F

{or}

RG 1.97 100%

{or}

RG 1.97 8.36E+06 Rad/Hr

{or}

RG 1.97 24/48 VDC battery bus Drywell pressure meter module and meter 1/2-CAC-PT-1230 N/A MCR 122°F

{or}

N/A 100%

{or}

N/A

[Site specific value]

{or}

RG 1.97

[Site specific value]

{or}

RG 1.97

[Site specific value]

{or}

RG 1.97 24/48 VDC battery bus Wetwell level sensor/

transmitter 1/2-CAC-LT-2601

"-10 to +6 feet

-17' RB CS SW Room 132°F

{or}

NA 100%

{or}

NA Use 1' TID of 9.13E5, but this is outside the 6' thick PC

concrete, so should be much lower IEEE 323-1974, IEEE 344-1975 148.8°F

{or}

RG 1.97 100%

{or}

RG 1.97 8.36E+06 Rad/Hr

{or}

RG 1.97 24/48 VDC battery bus Wetwell level meter and module 1/2-CAC-LT-2601 N/A MCR 122°F

{or}

NA 100%

{or}

NA

[Site specific value]

{or}

RG 1.97

[Site specific value]

{or}

RG 1.97

[Site specific value]

{or}

RG 1.97 24/48 VDC battery bus SAWA flow instrument and readout N/A 0-500 gpm

Outside, mounted on the FLEX pump 104°F N/A
Outside, radiation not a concern Commercial instrument qualified for over the road use, therefore qualified per NEI 12-06 120°F 100%

N/A FLEX Pump alternator

  • Denotes non-required item, added for site-specific design.
    • Denotes Control Building where local radiation levels are not applicable. Building has no significant radiation sources.

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 56

[September 12, 2017]

Table 2: Operator Actions Evaluation

{Black text in a cell is based on other black text in the same row.}

Operator Action Evaluation Time9 Validation Time Location Thermal conditions Radiological Conditions Evaluation 1 SAWA manual valve alignment in RB - 3 valves 0-1 hour

{Insert validation time}

RB ground floor 20 elevation Done in the first hour, so no concerns.

Done in the first hour, so no concerns.

Acceptable 2 Open RB roof hatch for ventilation 0-1 hour

{Insert validation time}

RB refueling floor Done in the first hour, so no concerns.

Done in the first hour, so no concerns.

Acceptable 3 Pneumatic hose connection 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />

{Insert validation time}

Between RB and TB in the seismic isolation space between the buildings.

Near the vent pipe on Unit 2.

Outside, so ambient conditions Action will be complete prior to venting start so no radiological concern.

{Generic text if outside action completed before venting starts.}

Acceptable 4 HCVS Valves switch actuation and instrument monitoring 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> (approximat e venting start)

{Insert validation time}

Main control room {insert ROS if not MCR for which last two columns will not be black text}

<120°F Per GOTHIC10 calculations performed for FLEX actions MCR is removed from the vent pipes and RP actions will provide protection from any airborne activity Acceptable MCR is a preferred location based on HCVS-FAQ-1.

9 Evaluation timing is from NEI 13-02 to support radiological evaluations.

10 Calculation RWA-L-1312-003, BNP CB FLEX Room Heat-up Analysis

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 57

[September 12, 2017]

Operator Action Evaluation Time9 Validation Time Location Thermal conditions Radiological Conditions Evaluation 5 Switch actuation for instrument backup power 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> (approximat e venting start)

{Insert validation time}

Main control room {insert location if not MCR for which last two columns will not be black text}

<120°F Per GOTHIC2 calculations performed for FLEX actions MCR is removed from the vent pipes and RP actions will provide protection from any airborne activity Acceptable MCR is a preferred location based on HCVS-FAQ-1.

6 Backup HCVS valve operation (if primary method fails) 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> (approximat e venting start)

{Insert validation time}

RB 50 elevation at Remote Operating Station 121°F maximum Based on GOTHIC11 evaluation. Short time action of approximately 5 minutes is acceptable.

Far from the Primary containment, shielded by intervening structures and concrete, no radiological concern.

Acceptable 7 SAWA pump staging and hose connection 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />

{Insert validation time}

East of RB near CST and RB Outside, so ambient conditions Opposite side of the RBs from the vent pipes, well shielded by structure and distance Acceptable 8 SAWA pump operation and refueling

>7 hours (maximum injection start time is 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />)

{Insert validation time}

East of RB near CST and RB Outside, so ambient conditions Opposite side of the RBs from the vent pipes, well shielded by structure and distance Acceptable 11 Calculation BNP-MECH-FLEX-0001 documents the Reactor Building Heatup Analysis

Final Integrated Plan HCVS Order EA-13-109 Revision [0]

Page 58

[September 12, 2017]

Operator Action Evaluation Time9 Validation Time Location Thermal conditions Radiological Conditions Evaluation 9 FLEX Generator connection and alignment

>24 hours N/A - >24 hours DG building No heat sources in either structure during this event, so no thermal concern.

Concrete structure on the opposite side of the RB from the vent pipes, so no radiological concern Acceptable 10 FLEX Generator operation and refueling

>24 hours N/A - >24 hours FLEX DG enclosure Outside, vented enclosure, so near ambient conditions Opposite side of the RBs from the vent pipes, well shielded by structure and distance, no radiological concern.

Acceptable 11 Start/

operate and refuel FLEX air compressor

>24 hours N/A - >24 hours Outside RB, east of the seismic isolation space Outside, so ambient conditions.

Shielded from containment and vent pipe by RB concrete walls, so no dose concern.

Acceptable No thermal or radiological concerns.