L-92-301, Application for Amend to License DPR-67,revising TS 4.5.2.d.1 to Remove Shutdown Cooling auto-closure Interlock Surveillance Requirement

From kanterella
(Redirected from ML17227A623)
Jump to navigation Jump to search
Application for Amend to License DPR-67,revising TS 4.5.2.d.1 to Remove Shutdown Cooling auto-closure Interlock Surveillance Requirement
ML17227A623
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 10/21/1992
From: Sager D
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17227A624 List:
References
L-92-301, NUDOCS 9210260313
Download: ML17227A623 (6)


Text

ACCELERATED D RIBUTIONDEMONS ATION SYSTEM l'.

REGULAT INFORMATION DISTRIBUTIO STEM (RIDS) t'ACCESSION NBR:9210260313 DOC.DATE: 92/10/21 NOTARIZED: YES FACI'L:50-335 St. Lucie Plant, Unit 1, Florida Power

& Light Co.

AUTH.NAME AUTHOR AFFIL'IATION SAGER,D.A.

Florida Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

DOCKET 05000335

SUBJECT:

Application for amend to license DPR-67,revising TS 4.5.2.d.l to remove shutdown cooling auto-closure interlock surveillance requirement.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal: General Distribution I

J D

NOTES:

RECIPIENT ID CODE/NAME PD2-2 LA NORRISgJ COPIES LTTR ENCL 1

1 2

2 RECIPIENT ID CODE/NAME PD2-2 PD COPIES LTTR ENCL 1

1 INTERNAL: ACRS NRR/DOEA/OTSBll NRR/DST/SICBSH7 NUDOCS-ABSTRACT OGC/HDS3 RES/DSIR/EIB EXTERNAL: NRC PDR 6

6 1

1 1

1 1

1 1

0 1

1 1

1 NRR/DET/ESGB NRR/DST/SELB 7E NRR/DST/SRXB SE O~C~

B PREG FI.L Ol NSIC 1

1 1

1 1

1 1

0 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

0 PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM PI-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 22 ENCL 20

I 0'

I I'

~l'I-

'I r,

P.O. Box 128, Ft. Pierce, FL 34954-0128 October 21, 1992 L-92-301 10 CFR 50.90 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.

C.

20555 RE:

St. Lucie Unit 1 Docket No. 50-335 Proposed License Amendment Removal of Shutdown Cooling Auto-Closure Interlock Surveillance Re irement Pursuant to 10 CFR 50.90, Florida Power

& Light Company (FPL) requests to amend Facility Operating License DPR-67 for St. Lucie Unit 1.

The proposed amendment revises Technical Specification 4.5.2.d.1 involving surveillance of the Shutdown Cooling System automatic closure interlock (ACI).

Approval of this proposal is requested by April 1993 to support a plant modification that would remove the ACI from the St. Lucie Unit 1 design during the Spring 1993 refueling outage.

Removal of this interlock and its surveillance requirement will provide a safety benefit in Shutdown Cooling System availability.

Attachment 1 is a

marked up copy of the proposed Technical Specification change.

Attachment 2 is a Safety Analysis in support of the proposed amendment.

Attachment 3 is the "Determination of No Significant Hazards Consideration."

The proposed amendment has been reviewed by the St. Lucie Facility Review Group and the Florida Power

& Light Company Nuclear Review Board.

In accordance with 10 CFR 50.91 (b)(1),

a copy of the proposed amendment is being forwarded to the State Designee for the State of Florida.

Please contact us if there are any questions about this submittal.

Very truly yours, Ou~

D. A.

ger Vice r sident St. Lucie Plant DAS/RLD/kw DAS/PSL 0807-92 Attachments cc:

Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Mr.

Jacob D.

Nash, Florida Department of Health and psOO6gRehabilitative Services

)0(

60SiS ~>>0 1

an FPL Group company

+2 DOCp, 050003>5 PDR l

PDR P

44 Wt 4 q, 1

g

~

g~ j I'

St. Lucie Unit 1 Docket No. 50-335 Proposed License Amendment Removal of Shutdown Cooling Auto-Closure Interlock Surveillance-Re uirement STATE OF FLORIDA

)

)

COUNTY OF ST.

LUCIE

)

SS

~

D. A. Sager being first duly sworn, deposes and says:

That he is Vice President, St. Lucie Plant for the Nuclear Division of Florida Power

& Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best, of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.

STATE OF FLORIDA COUNTY OF Q7

~ EQC-/L The foregoing instrument was acknowledged before me this

'WI day of 19 '7Z-by D.,<A. Sage;.,

who is personally known to me and'ho~'did', take an oath.

/41 s.'", 4'8"ECA Name of Notary Public My commission expires IZ Commission No.

~REN'+<S~,

~s~@ rt r'er~8 Nosy pu iaB ~8 1994

~ C m!sSlon MiCS coMMNGC

E C