AS R5011

~o Cy Cl0 I

C O

4'~

qO

++*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON> D.C. 205554001 0

8 G

CO

- 3 U

EN Amendment No.

156 License No. DPR-67 The Nuclear Regulatory Commission (the Commission) has found that:

The application for amendment by Florida Power 8 Light Company (the licensee),

dated June 3, 1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facilitywilloperate in conformity with the application, the provisions of the, Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment willnot be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9808210<~6

+~000~@

P

~

~

II

.~ 2.

Accordingly, Facility Operating License No. DPR-67 is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and by amending paragraph 2.C.(2) to read as follows:

(2)

Technical 0 s The Technical Specifications contained in Appendices A and B, as revised

,through Amendment No.

15$ are hereby incorporated in the license..The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days of receipt.

FOR THE NUCLEAR REGULATORYCOMMISSION Frederick J. Hebdon, Director Project Directorate II-3 Division of Reactor Projects - I/II Ofice of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

August 10, 1998

C N

IC S

0 156 0

AC 0

RATING ICE SE 0 DPR-67 OC T 0

-335 Replace the following pages of the Appendix "A"Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

~se Pacae 3/4 11-14 3/4 11-14

~

~

RADIO CTIVE EF L EN PLOS VE S

I 3.11.2.5 The concentration of oxygen in the waste gas decay tanks shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume.

A

~CTION:

a.

With the concentration of oxygen in the waste gas decay tank greater than 2% by volume but less than or equal to 4% by volume, reduce the oxygen concentration to the above limits within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

b.

With the concentration of oxygen in the waste gas decay tank greater than 4% by volume and the hydrogen concentration greater than 2% by volume, immediately suspend all additions of waste gases to the system and immediately commence reduction of the concentration of oxygen to less than or equal to 2% by volume.

c.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

4.11.2.5.1 The concentration of oxygen in the waste gas decay tank shall be determined to be within the above limits by continuously monitoring the waste gases in the on setvice waste gas decay tank.

4.11.2.5.2 With the oxygen concentration in the on service waste gas decay tank greater than 2% by volume as determined by Specification 4.11.2.5.1, the concentration of hydrogen in the waste gas decay tank shall be determined to be within the above limits by gas partitioner sample at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

When continuous monitoring capability is inoperable, waste gases shall be monitored in accordance with the actions specified for the Waste Gas Decay Tanks Explosive Gas Monitoring System in Chapter 13 of the Updated Final Safety Analysis Report.

ST. LUCIE-UNIT1 3/4 11-14 Amendment N0.69,+%,45&, 156

~R REGS

~o Cy O

IVl e

0

+G

~O

++*++

UNITED STATES NUCLEAR REGULATORY COMIVIISSION WASHINGTON> D.C. 2055&4001 OU S

OF LO A MUNICI G

NCY OC 50-3 S

UC M

N 0

C OP TING IC S

Amendment No.

94 License No. NPF-16 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Florida Power 8 Light Company, et al. (the.

licensee), dated June 3, 1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facilitywilloperate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment willnot be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

Accordingly, Facility Operating License No. NPF-16 is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and by amending paragraph 2.C.2 to read as follows:

2.

T c ni alS ecifc io The Technical Specifications contained in Appendices A and B, as revised through Amendment No.

94, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days of receipt.

FOR THE NUCLEAR REGULATORY COMMISSION rederick J. Hebdon Director F

Project Directorate II-3 Division of Reactor Projects - I/II:

Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

August 10, 1998

C NT TO ICE OF C

I OP RATING C

0

- 6 D

5-89 Replace the following pages of the Appendix "A"Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

emovePa e

3/4 11-14

~e~ae 3/4 11-14

O.

4

AD C

EEFFL E T EXPLO IVE GAS MI 3.11.2.5 The concentration of oxygen in the waste gas decay tanks shall be limited to less than or equal to 2% by volume whenever the hydrogen concentration exceeds 4% by volume:

~L'IY'. A'll a.

With the concentration of oxygen in the waste gas decay tank greater than 2% by volume but less than or equal to 4% by volume, reduce the oxygen concentration to the above limits within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

b.

With the concentration of oxygen in the waste gas decay tank greater than 4% by volume and the hydrogen concentration greater than 2% by volume, immediately suspend all additions of waste gases to the system and immediately commence reduction of the concentration of oxygen to less than or equal to 2% by volume.

c.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

4.11.2.5.1 The concentration of oxygen in the waste gas decay tank shall be determined to be within the above limits by continuously* monitoring the waste gases in the on service waste gas decay tank.

4.11.2.5.2 With the oxygen concentration in the on service waste gas decay tank greater than 2% by volume as determined by Specification 4.11.2.5.1, the concentration of hydrogen in the waste gas decay tank shall be determined to be within the above limits by gas partitioner sample at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

When continuous monitoring capability is inoperable, waste gases shall be monitored in accordance with the actions specified for the Waste Gas Decay Tanks Explosive Gas Monitoring System in Chapter 13 of the Updated Final Safety Analysis Report.

ST. LUCIE - UNIT2 3(4 11-14 Amendment N0.57,89, 94