September ll, 1987 Docket No. 50-335 INTRODUCTION The NRC staff met with FP8L personnel on September 2,

1987 in Bethesda, Maryland to discuss the licensee's proposal to rerack the spent fuel pool.

The scope of the meeting focused on the questions that were sent to the licensee on July 16, 1987.

Enclosure 1 identifies the meeting attendees.

Enclosure 2 provides the questions that were discussed.

SUMMARY

The licensee provided to'he staff a draft of their answers to the questions.

The draft document is provided as Enclosure. 3.

The staff felt that the draft answers were adequate in some cases, but that additional information should be provided in other cases.

The licensee plans, to submit the final answers to the questions in the next few weeks.,

DISTRIBUTION JMinns Ed d

NRC PDR JPartlow Local PDR ACRS (10)

PD22 Rdg BTroskoski LICENSEE:

Florida Power and Light Company (FP8L)

ETourigny JRidgely HBerkow HAshar FACILITY: St. Lucie Plant, Unit No.

1 OGC-Bethesda PWu LKopp ISpickler

SUBJECT:

SUMMARY

OF SEPTEMBER 2, 1987 MEETING WITH FPSL AND NRC STAFF REGARDING THE RERACKING OF THE SPENT FUEL POOL (TAC NO. 65587)

Enclosures:

1.

List of Attendees 2.

List of guestions 3.

Draft Answers cc w/enclosures:

See next page E. G. Tourigny, Project Manager Project Directorate II-2 Division of Reactor Projects-I/II L

Dt r

9/ i/87 PMR+g4 ETourigny 9/j/ /87 9//(/87 8709280289 870911 PDR ADOCK 05000335>

P PDR

~

'4 g~

4 t

f' p

P

'1 li f

g I

ll, 1 )I l

Cy e

Mr. C. 0.

Woody Florida Power 8 Light Company St. Lucie Plant CC:

Mr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Tallahassee, Florida 32304 Resident Inspector c/o U.S.

NRC 7585 S.

Hwy AIA Jensen Beach, Florida 34957 State Planning 5 Development Clearinghouse Office of Planning 5 Budget Executive Office of the Governor The Capitol Building Tallahassee, Florida 32301 Harold F. Reis, Esq.

Newman 5 Holtzinger 1615 L Street, N.W.

Washington, DC 20036 Norman A. Coll, Esq.

McCarthy, Steel, Hector and Davis 14th Floor, First National Bank Building Miami, Flor ida 33131 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Mr. Weldon B. Lewis, County Administrator St. Lucie County 2300 Virginia Avenue, Room 104 Fort Pierce, Florida 33450 Mr. Charles B. Brinkman, Manager Washington - Nuclear Operations Combustion Engineering, Inc.

7910 Woodmont Avenue

Bethesda, Maryland 20814 Jacob Daniel Nash Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.

Tallahassee,,

Florida 32399-0700 Regional Administrator, Region II U.S. Nuclear Regulatory Comnission Executive Director for Operations 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323

~

I'

~

ENCLOSURE 1

NRC/FPSL MEETING ST.

LUCIE PLANT, UNIT NO. I SPENT FUEL POOL EXPANSION SEPTEMBER 2, 1987 NAME E.

G. Tourigny J.

N. Ridgely T. Roberts H. Ashar E. J.

Weinkam G. J. Keller E.

V. Webb D. H. Bjorkbom AFFILIATION NRC PM for St. Lucie Plant NRC/DEST/PSB FPSL - Engineering NRC/DEST/ESGB FPSL - Nuclear Licensing FPSL - Engineering FP8L - Engineering Serch Lic. - Bechtel

ENCLOSURE 2

REQUEST FOR ADDITIONAL INFORMATION SPENT FUEL POOL CAPACITY EXPANSION ST.

LUCIE UNIT 1 DOCKET NUMBER:

50-335 2.

3 ~

4 ~

5.

6.

7.

In the June 12, I987 submittal, Table 3-11 specifies the coolant flow rate for the spent fuel pool cooling systems to be 3560 gpm.

Indicate whether this is the flow rate with one spent fuel pool cooling system pump running or with both pumps running.

The submittal specifies that the. spent fuel pool cooling system consists, in part, of two spent fuel pool cooling system pumps and one heat exchanger.

Since all heat exchangers require maintenance at some point fn time, it is not clear how the spent fuel pool will be cooled during the time that the single spent fuel pool cooling system heat exchanger is out of service for maintenance.

Provide a discussion of how the spent fuel pool is cooled and the temperature is maintained below the Technical Specification temperature limit for the following conditions:

I)

The heat exchanger is out of service for plugging of failed tubes.

2)

The heat exchanger is out of service for cleaning of the tubes.

3)

The heat exchanger is out of, service for replacement.

Provide a drawing (or drawings as necessary) which shows the arrangement of the spent fuel pool cooling system piping fn and around the spent fuel pool.

Page 4-28 states that the fuel assembly drop accident was evaluated with the dropped assembly being positioned 36 inches above the top of the spent fuel storage racks.

It is not clear that this represents the maximm height that the fuel assembly will be carried over the spent fuel storage racks.

Specify the maximum carrying height for fuel assemblies within the spent fuel pool area and discuss the physical design features which prevent a fuel assembly from being carried higher than the specified height, or verify that the fuel assembly drop accident analysis is bounding by assuming total failure of all effected fuel assemblies.'rovide drawings which show the movement of both'he existing and the new racks throughout their entire path of travel from outside of the fuel handling building until their final 1ocation in the spent fuel pool (and the reverse for the existing racks).

For each step in the replaceaent of the racks, provide drawings which show the location of the spent fuel and the movement of the fuel which demonstrates that no heavy load will be carried over spent fuel or over any rack which contains spent fuel.

(Note:

This information can be placed on the set of drawings provided in response to question 5).

Provide additional discussion on the temporary crane that will be used to handle the spent fuel storage racks within the fuel building.

As part of the discussion, specify 1) whether the crane is single failure proof;

2) whether the temporary crane will be carried over the spent. fuel pool; and 3) the load path that the fuel building crane will take to carry the temporary crane.

Provide drawings of the temporary crane and pertinent details which demonstrate the crane's compliance with the guidelines of NUREG-0612 and NUREG-0554. If the temporary crane is not single fai,lure proof, provide the results of the analysis which demonstrates that the appropriate safety factors have been applied to the crane and that load handling by the crane will be in accordance with the guidelines of NUREG-0612.

8.

Provide drawings of the lifting rigs.

Verify that the lifting rigs are single failure proof and meet the guidelines of HUREG-0612.

9.

Assuming that a rack is dropped, provide a discussion of how it will be verified that no damage has been done to the pool liner, spent fuel pool cooling system piping in the spent fuel pool, or to other racks.

Assuming that the dropped load was the result of the lifting attachment, describe how you would provide a new lifting attachment that makes the liftsingle failure proof.

Provide a discussion of the potential splashing effects from the dropped rack on the loss of suction for the spent fuel pool cooling system and with respect to the effects on plant personnel in the area.

QUESTION 81 ENCLOSURE 3

>-LR-87-37 e 4 of 22 P,~J QUESTION:

In the June 12, 1987 submittal, Table 3-11 specifies the coolant flow rate for the spent fuel pool cooling systems to be 3560 gpm.

Indicate whether this is the flow rate with one spent fuel pool cooling system pump running or with both pumps running.

RESPONSE

The coolant flow specified in Table 3-11 of the June 12, 1987 submittal refers to the component cooling water (CCW) flow to the spent fuel pool cooling system (SPPCS) heat exchanger.

The CCW system at St Lucie Unit 1 consists of 3 pumps; two pumps run during all normal operating conditions, while the third is maintained in standby.

The CCW system provides the coolant for the SFPCS heat exchanger and the CCW flow remains constant at 3560 gpm during normal operating conditions.

With respect to Tables 3-13, 3-14, 3-16 and 3-17 of the June 12, 1987 submittal the number of spent fuel pool cooling pumps operating is described in Subsection 3.2.1 of the Safety Analysis report dated June 12, 1987.

For normal refueling discharge conditions, one fuel pool pump (SPPCS flow rate 1500 gpm) and the fuel pool heat exchanger are in service.

During abnormal refueling conditions, such as full core discharge, two fuel pool pumps (SFPCS flow rate 3000 gpm) and the heat exchanger are in service.

~

~

QUESTION 42 JPE-LR-87-37 5 of 22 QUESTION:

The submittal specifies that the spent fuel pool cooling system

consists, in part, of two spent fuel pool cooling system pumps and one heat exchanger.

Since all.heat exchangers require maintenance at some point in time, it is not clear how the spent fuel pool will be cooled during the time that the single spent fuel pool cooling system heat exchanger is out of service for maintenance.

Provide a

discussion of how the spent fuel pool is cooled and the temperature is maintained below the Technical Specification temperature limit for the following conditions'.

1."

The heat exchanger is out of service for plugging of failed tubes.

2.

The heat exchanger is out of service for cleaning of the tubes'.

The heat exchanger is put of service for replacement.

RESPONSE

Due to the low pressure, low temperature service environment, and the carefully controlled water chemistry, (of both the CCW and SFPCS) the SFP heat exchanger will only infrequently require maintenance.

Maintenance operation such as cleaning and tube plugging can normally be scheduled in advance for periods of low pool decay heat loads ()ust before a normal refueling).

The spent fuel pool heat exchanger is designed for the life of the plant, therefore its replacement is not postu/cited.

However, in

'he extremely unlikely event that replacement is required, alternate means of providing cooling to the SFP co~ld'e impleme~fecf dur s'ny the pep/~c%Nte,ll f, Should the heat exchanger bp out of service for a sufficient period to allow boiling in the SFP, redundant sources of makeup water to the SFP are available, as discussed in St Lucie Unit 1 FSAR Amendment No 6, Section 9.1.3.4 and in Section 3.2.3 of the Safety Analysis Report for the Spent Fuel Pool Rerack date June 12, 1987.

Boiling of the water in the SFP is adddressed in Section 9.1.3.4 of the FSAR and in Section 3.2.2.4 of the Safety Analysis Report.

(There is no Technical SpecificaTion temperature limit for the SFP.)

DRAFy

QUESTION <<3 l?RAFT E-LR-87-37 e 6 of 22 QUESTION:

Provide a drawing (or drawings as necessary) which shows the arrangement of the spent fuel pool cooling system piping in and around the spent fuel pool.

RESPONSE

Sketches SK-83-02-M-002 and SK-83-02-M-003 (attached) show the arrangement of the spent fuel pool cooling'system in and around the spent fuel.pool.

DRAFy

t

JPE"LR-87-37 e

7 of 22 QUESTION 44 QUESTION:

Page 4-28 states that the fuel assembly drop accident was evaluated with the dropped assembly being positioned 36 inches above the top,of the spent fuel storage racks. It is not clear that this represents the maximum height that the fuel assembly will be carried over the spent fuel storage racks.

Specify the maximum carrying height for fuel assemblies within the spent fuel pool area and discuss the physical design features which prevent a fuel assembly from being carried higher than the specified height, or verify that the fuel assembly drop accident analysis is bounding by assuming total failure of all effected fuel assemblies.

RESPONSE

The design of the spent fuel handling machine provides for a normal upper limit on the hook travel of Elevation 85'"7 (palm of hook).

This corresponds to "an elevation of 37'-5 1/2 at the bottom of the shortest fuel assembly.

The top of the high density spent fuel racks is at elevation 36'-2 5/8, resulting in a clearance of 14 7/8" between the top of the racks and the bottom of the fuel assembly under normal conditions.

Should all interlocks fail, the physical limitations of the spent fuel handling machine will prevent the hoisting of the fuel assembly above an elevation at which 9'f water cover remains above the top of the active fuel.

This condition corresponds to an elevation of 39'-3 1/8 at the bottom of the shortest fuel

assembly, resulting in a clearance of 36 1/2" between the top of the racks and the bottom of the fuel assembly.

This is the maximum possible drop height for the design of the racks.

iL, QUESTION 05

~

DRAPE JPE-LR-87-37 ge 8 of 22 QUESTION:

Provide drawings which show the movement of both the existing and the new racks throughout their entire path of travel from outside of the fuel handling building until their final location in the spent fuel pool (and the reverse for the existing racks).

RESPONSE

For the removal of the racks from the spent fuel pool cask storage area to outside the spent fuel pool (see General Arrangement sketch SK-83-02-M-001 attached) each rack will be removed individually following a path that does not carry the reek over-o'Ocr racks containing spent fuel (see response to question number 6).

Each rack will be removed by crane and transported over a prescribed path to the spent fuel cask storage area.

The old racks will be washed down.

The old dry spent fuel racks will be placed in polyethylene bags and removed to the cask equipment decontamination area.

The polyethylene bags will be removed and discarded and the racks will be cleaned until desired results are achieved.

The racks will be inserted in clean polyethylene bags and moved to the cask storage area.

For installation of the spent fuel racks the racks will be brought from the onsite storage location to the cask washdown area and cleaned as required.

After cleaning is complete the racks will be transported into the spent fuel cask storage area.

From the spent fuel cask storage area the racks will be transported over the spent fuel pool (see response to number 6) to the racks'roper location, where they will be placed.

During the process the racks will not be carried over racks containing spent fuel.

~

~

~ ik qUESTION 46 JPE-LR-87-37 10 of 22 QUESTION:

For each step in the replacement of the racks, provide drawings which show the location of the spent fuel and the movement of the fuel which demonstrates that no heavy load will be carried over spent fuel or over any rack which contains spent fuel.

(Note:

This information can be placed on the set of drawings provided in response to question 5).

RESPONSE

The attached drawing shows the various locations of the spent fuel during the rack installation.

Described below is the sequence of rack removal and installation.

Following the removal plan (see question f5), remove Racks 1

and 2 from the pool as shown in Figure 41.

2 ~

Following the installation plan (see question f5), install Racks FlW2W1 as shown in Figure 42.

3 ~

Relocate all of the 238 fuel assemblies stored in Rows "L through T" to new racks P1W2&1 as shown in Figure 43.

4 ~

Following the removal plan (see question f5), remove all four racks, which are in Rows "L through T", removing 3, 4, 5 and 6 shown in Figure f3.

Following the installation plan (see question f5), install new Racks D2, C3, Cl, as shown in Figure f4.

6.

Relocate all the assemblies stored in old racks into new racks as shown in Figure f5.

7 ~

Following the removal plan (see question P5),

remove all eight Racks 7, 8, 9, 10, ll, 12, 13 and 14 shown in Figure P5.

8.

Following the installation plan (see question

$5), install new Racks D3, B2, C4, Bl, C2, A2, Al, Dl, Hl, E2 and El shown in Figure f6.

REMOVE'ASK AREA z

7X IO

)l 7XIQ 7X7 7X7 g7X7 7X7 IO AX g9 787 8

7 7X7

,'7X7

/)

7X7

/)

7X7 7X7

~

7X7

t. '=EXISTIXS RACKS I=FUEL Fl GURE l

TITLE: SE(}DEECE OF RACK REMOVAL AND IKSTALL-nuuaar uautu eonau~txan

Gl CASK AREA 7X7 5

X7 7X7

~g'7X7 r I4 7X7 7X7 r) 7X7 r7X7

~/

IZ 7X7 7X7'+

FIGURE 2 Q = NEW RACKS

';=EXISTING RACKS

@=FUEL

! TITLE: SEQUENCE OF RACK REMOVAL AhD IhSTALL<<

nuaaar uutltu can~~ion EhCLOSURE:

2 of e

REL CATED FUEL ASSER%LIES FROM RACKS 3 THRU 6 Fl Gl R EViOVE nov, S-7Z I

6 7X7 i

7X7 7 'XT

~10 9

r 7X7 7X7 F14 7X7

~8 7pi7

~12 7X7

/7 7X I ll<

(X7>>

FIGURF 3

=NEW RACKS

" "=EX lSTlflG RACKS kg=FUEL DRAFT TITLE: SEQUENCE OF RACK REMOVAL AND INSTALL-nuclear ual>~ cane~~~~

EN CLOS URE:

0

Pa~ l4of lz DRAFy Gl CASK AREA D2 CI 777 'X B

7X(

/

7>,7 F14 7X7 iZ 7X7 g

l~l'%7

=NEW RACKS

'. ":=EXISTlNG hACKS FIGURE 4 TITLE: SEQUENCE OF RACK REMOVAL AhD INSTALL-I nuuaar uatleu canaeru1euan I

ENCLOS VRE:

4 o f 6

RELOCATED FUEL ASSEMBLIES DP/pp FROVI RACKS 7 THRU 10 62 CASK AREA CI REV:CVE Rf CKS 7 THRU )4 7X7 t

7X7

)

7X7

)

7X7 7X7 'X7 7X7 ll 7X7 I

Q-NEW RACKS

": = EX 1ST I NG RACKS

@ F""

F~SuzE 5 T?TLE:

SEQUENCE OF RACK REMOVAL hND 1ÃSTALL nuu ear uuticu cnnacn~an ATT ON ENCLOSURE:

S oj 6

GI CASK AREA D2 D5 C2

. A2 Al Q=NeW awCKS Q =FUEL FIGURE 6 DRAET nuctaar uutteu can TITLE: SEQVENCE OF RACK REMOVAL AND INSTALL-ATION ENCLOSVRE:

6 of 6

Page 17 of 22

~ ~~

QUESTION 47 QUESTION:

Provide additional discussion on the temporary crane that will be used to handle the spent fuel storage racks within the fuel building.

As part of the discussion, specify 1) whether the czane is single failure proof;

2) whether the temporary crane will be carried over the spent fuel pool; and 3) the load path that the fuel building crane will take to carry the temporary crane.

Provide drawings of the temporary crane and pertinent details which demonstrates the crane's compliance with the guidelines of NUREG-0612 and NUREG&554. If the temporary crane is not single failure proof, provide the results of the analysis which demonstrates that the appropriate safety factors have been applied to the crane and that load handling by the crane will be in accordance with the guidelines of NUREG-0612.

RESPONSE

At present information concerning the following aspects of the temporary crane are unavailable:

1.

Guidelines 2.

Single Failure Proof 3.

Safety Factors The temporary crane will not be carried over the spent fuel.

FPL is developing detailed drawings of the installation of the temporary crane.

The load pattern that the fuel building crane will take to carry the temporary crane as well as the requested temporary crane information is being developed.

DRAFT

JPE-LR-87-37

~ ih~

~

QUESTION 88 QUESTION:

Provide drawings of the lifting rigs.

Verify that the lifting rigs are single failure proof and meet the guidelines of NUREG-0612.

RESPONSE

The lifting rig used for the installation of the new racks meets the requirements of NUREG&612.

The rig is provided with four support points; in the event of the failure of any one of these attachment points, the remaining three would be capable of retaining the load in a safe condition, thus satisfying the single-failure-proof criterion.

See attached drawing 8770-11891 Rev 1.

Information regarding the lifting rig used for the removal of the existing racks is being developed.

i

\\

n r

'I I

~

QUESTION 49'PE-LR-87-37 Page 19 of 22 QUESTION:

Assuming that a rack is dropped, provide a discussion of how it will be verified that no damage has been done to the pool liner, spent fuel pool cooling system piping in the spent fuel pool, or to other racks.

Assuming that the dropped load was the result of the lifting attachment, describe how you would provide a new lifting attachment that makes the lift single.failure proof.

Provide a discussion of the potential splashing effects from the dropped rack on the loss of suction for the spent fuel pool cooling system and with respect to the effects on plant personnel in the area.

RESPONSE

Assuming that a rack is dropped in the pool, it would be possible

'o assess potential damage to the pool liner, pool cooling

system, or other racks by the use of remote video equipment by the leak chase system or if previous methods prove inconclusive, by divers.

The leak chase system is discussed in the St Lucie Unit 1 FSAR Amendment No.

6 section 9.1.2.2

~

Assuming that a rack has been dropped 'into the pool, reattachment to. the lifting rig, or the second available lifting rig assuming the first is damaged, would be made by either a long handled tool or by divers if attachment cannot be made by the long handled tool.

In the unlikely event splashing does occur Health Physics personnel will be available to decontaminate any personnel contaminated by splashing.

It is not postulated that splashing/wave action resulting fr'om the drop of a rack into the SFP would result in the loss of suction for the SFP cooling

system, due to transient wave action, because of the location of the suction line.

(Approximately 6 feet below the water surface).

However, in the unlikely event that suction is lost, the cooling system could be vented and returned to service by operator action.

DRAFT

3l-G I3-t Fll3

<OL< UF. DOOR IQQNIID6 A 1 p Q ~ IuH IS nooR Cc auwc CASK WASNDo~II AR,Eh C"CVA 0

IO O~

5UMP QO'f El. 20.00' 5LO G'~O

~ fy I

SKhat.

CA 5'fOA CASK IIEAD

'E 9'f Oh'uVL 5SSl 10'ff SID<<4a CASKlf LARGE QQuIPIAEN ~

DtCDIITAN AAth C>>" CUA IS'-ll/L

~lK x

<err. a PiAuS) 5l.

I 10 SO SPECI Ch'o K f44.

%TOR ttlbad

'uI o4 I.

1

~

REC UELING CANAI.

SUBMERSI BI.E 5VMP PUMP FVIL POOL FLbNf. EL. CI.SO 725 Fl!i~l 455EHbLY 5T0446E.

SPCNT FIfLL AhC.I%5 S.gq I.Isath, 0

0 I8J Zc g

~J r

c 0

cd 0

ng rlO+

acr lO 2

r 0

4

~,

e e..'r II fffeOl WIff4 URf ~MT fl Ifnf fffCf ISMN Sce WflUNWO %It I GENERAL ARRANGEMENT FUEL HANDUNG BUILDING PLAN SK-88-02

-M-001