Annual Radioactive Environmental Monitoring Report and Radioactive Effluent Release Report
ML17048A469
Person / Time
Site: La Crosse  File:Dairyland Power Cooperative icon.png
(DPR-045)
Issue date: 02/16/2017
From: Gerard van Noordennen
LaCrosseSolutions
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
Shared Package
ML17048A467 List:
References
LC-2017-0016
Download: ML17048A469 (57)


Text

f I

I I

-~

LACROSSESOLUTIONS 10 CFR 50.36(a)(2)

February 16, 2017 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 La Crosse Boiling Water Reactor Facility Operating License No. DPR-45 NRC Docket Nos. 50-409 and 72-046 LC-2017-0016

Subject:

La Crosse Boiling Water Reactor (LACBWR) Annual Radioactive Environmental Monitoring Report and Radioactive Effluent Release Report.

In accordance with Facility Operation License No. DPR-45, Quality Assurance Program*

Description (QAPD) Appendix C, Section 2.5.1, "Annual Radiological Environmental Monitoring Report," and Section 2.5.2, "Annual Radioactive Effluent Release Report," this letter submits these reports for the year 2016. The reports are required to be submitted prior to March 1 per QAPD Appendix C, Section 2.5 "Reporting Requirements," and are provided as enclosures to this letter.

The Radiological Effluent Release Report also contains changes to the Process Control Program (PCP) and the Offsite Dose Calculation Manual (ODCM) per the requirements of QAPD Appendix C, Section 2.1, "Process Control Program;" and Section 2.2, "Offsite Dose Calculation Manual," respectively. The current PCP and _ODCM are provided as enclosures to this letter..

There are no new regulatory commitments in this submittal.

If you have any questions about this submittal please contact.Mr. Joseph Jacobsen at.

(608) 689-4259.

. Respectfully, G~~--~

Gerard van Noordennen Vice President Regulatory Affairs Attachments:

1. LACBWR Annual Radiological Environmental Operating Report
2. LACBWR Offsite Dose Calculation Manual
3. LACBWR Process Control Program.

S4601 State Highway 35, Genoa, WI 54632

--IE 4-g

/JM55b/

jJ rv15 s --zJp

,VM 5S

--- ****- ~-

LaCrosseSolutions LC-2017-0016 Page 2 of2 cc:

Marlayna Vaaler, U.S. NRC Project Manager Regional Administrator, U.S. NRC, Region III Service List (Cover letter only, no attachments)

__.::..._-__... ---~- *- -... -.

La Crosse Boiling Water Reactor Service List cc:

Ken Robuck Group President Disposal and Decommissioning Energy Solutions 299 South Main Street, Suite 1700 Salt Lake City, UT 84111 John Sauger Executive VP and Chief Nuclear Officer ReactorD&D Energy Solutions 2701 Deborah A venue Zion, IL 60099 Gerard van Noordennen VP Regulatory Affairs Energy Solutions 2701 Deborah Avenue Zion, IL 60099 Joseph Nowak General Manager LaCrosseSolutions S4601 State Highway 35 Genoa, Wl54632-8846 Dan Shrum Senior VP Regulatory Affairs EnergySolutions 299 South Main Street, Suite 1700 Salt Lake City, UT 84111 Russ Workman.

General Counsel EnergySolutions

  • 299 South Main Street, Suite 1700 Salt Lake City, UT 84111 Jerome Pedretti, Clerk Town of Genoa E860 Mundsack Road Genoa, WI 54632 Jeffery Kitsembel Division of Energy Regulation Wisconsin Public Service Commission P.O. Box 7854 Madison, WI 53 707-7854 Paul Schmidt, Manager Radiation Protection Section Bureau of Environmental and Occupational Health Division of Public Health Wisconsin Department of Health Services P.O. Box 2659 Madison, WI 53701-2659 Barbara Nick President and CEO Dairyland Power Cooperative 3200 East A venue. South, La Crosse, WI 54602-0817 Cheryl Olson, ISFSI Manager La Crosse Boiling Water Reactor Dairyland Power Cooperative S4601 State Highway 35 P.O. Box 817 Genoa, Wl54632-8846 Lane Peters La Crosse Boiling*Water Reactor Dairyland Power Cooperative S4601 State Highway 35 Genoa, WI54632-8846 Thomas Zaremba Wheeler, Van Sickle and Anderson, S.C.

44 East Mifflin Street, Suite 1000 Madison, WI 53703 John E. Matthews Morgan, Lewis & Bockius LLP 1111 Pennsylvania A venue, NW Washington, DC 20004

LaCrosseSolutions LC-2017-0016: Attachments LACBWR Annual Radiological Environmental Ope~ating Report

--~---*-*:__:...... _ -- =-----

~--**--- -----~---:* *_::,_*_:_:-__, ____ _

ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT FOR THE LA CROSSE BOILING WATER REACTOR (LACBWR)

(January 1 to December 31, 2016)

LACROSSESOLUTIONS 4601 STATE HIGHWAY 35 GENOA, WI 54632


~------ --


~-~ -

TABLE OF CONTENTS SECTION A: RADIOACTIVE EFFLUENT REPORT Section 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Introduction.................................................................................

Regulatory Limits........................................................................

Effluent Release Concentration Limit..........................................

Average Energy....................................,.....................................

Analytical Methods......................................................................

Batch Releases...........................................................................

Abnormal Releases....................................................................

Estimated Total Analytical Error.................................................

Offsite Dose Calculation Summary and Conclusions..................

Offsite Dose Calculation Manual (ODCM) Review......................

Process Control Program (PCP) Review........................ ;...........

SECTION A: RADIOACTIVE EFFLUENT REPORT Table No.

Title 1A Effluent and Waste Disposal - Airborne Particulate Effluents Summation of All Releases.........................................................

1 B Effluent and Waste Disposal - Airborne Particulate Effluents Ground Level Release................................................................

2A Effluent and Waste Disposal - Liquid Effluents Summation of All Releases........................".................................

28 Effluent and Waste Disposal - Liquid Effluents.......... '................

3 Effluent and Waste Disposal Annual Report - 2016 Solid Waste and Irradiated Fuel Shipments..,.................................................

1 2

4 4

4 5

6 6

12 13 13 Page

  • 7 8

9 10 11

---~--- ---- - - -

TABLE OF CONTENTS SECTION B: RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT Section 1.0 2.0 3.0 4.0 Title Introduction......................................... ~.......................................

Sample Collection.......................................................................

Results of the 2014 Radio-Environmental Monitoring Survey.....

Conclusions................................................................................

lnterlaboratory Comparison Program Results.............................

SECTION B: RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT Table No.

Title 4

ISFSI Environmental TLD Locations..........................................

5 Sample Frequency and Analysis of Radio Environmental Samples 6

Low Volume Env.ironmental Air Monitoring Station Locations 7

LACBWR Environmental TLD Locations....................................

8 Sample Frequency and Analysis of Radio Environmental Samples 9

Quarterly Environmental TLD Results in LACBWR Vicinity........

10 Bi-Weekly Gross Beta Environmental Air Sample Analysis Results 11 Bi-Weekly Gamma Spec Env. Air Sample Analysis Results......

12 Semi Annual Mississippi River Water Analysis Results 13 Semi Annual Mississippi River Sediment Analysis Results 14 Quarterly Environmental TLD Results for ISFSI Area SECTION B: RADIOLOGICAL ENViRONMENTAL MONITORING REPORT Page 1

2 3

5 5*

Page 11 12 13 14 15 16 17 18 24 25 26 Figure No.

Title Page 1

LACBWR Property Map..............................................................

7 2

LA CB WR RCA Fence Line Environmental TLD Locations.........

8 3

LACBWR Environmental Low Volume Air Sampler Locations....

4 ISFSI Environmental TLD Locations..........................................

ii

SECTION A RADIOACTIVE EFFLUENT REPORT

INTRODUCTION The La Crosse Boiling Water Reactor (LACBWR), also known as Genoa Station No. 2, is located on the east bank of the Mississippi River near Genoa, Vernon County, Wisconsin. The plant was designed and constructed by the Allis-Chalmers Manufacturing Company. It was completed in 1967 and had a generation capacity of 50 MW (165 MW(th)). The reactor is owned by Dairyland Power Cooperative (DPC).

The reactor went critical in July 1967 and first contributed electricity to the DPC system in April 1968. After completing full power tests in August 1969, the plant operated between 60% and 100% full power, with the exception of plant shutdowns for maintenance and repair until 1987.

In April of 1987 plant operation was ceased. The reactor was defueled and placed in a SAFSTOR mode. In August of 1987 a possession-only license was received. In 2007 the reactor ve~sel was removed from the site and buried at the Barnwell waste repository. In 2012 all spent fuel was placed in dry storage and placed ~t the LACBWR Independent Spent Fuel Storage Installation (ISFSI).

In June of 2016 DPC, working with the selected decommissioning contractor LaCrosseSolutions LLC, transferred their NRC License to LaCrosseSolutions LLC for the purposes of decommissioning the site to unconditional release criteria, per license termination plan criteria.

In accordance with LC-RP-PG-004 "Radiological Environmental Monitoring Program and Preparation of the Annual Radiological Environmental Operating Report", this document is the Annual Radiological Environmental Operating Report (AREOR) for the Period January 1 through December 31, 2016.

1

__ -:_ -*----=----- ---::'.'.'.......:..::~ __ *.:_...: ___ --*- ---------- --*- --

EFFLUENT AND WASTE DISPOSAL REPORT (Supplemental Information)

FACILITY: La Crosse Boiling Water Reactor LICENSEE: LaCrosseSolutions LICENSE NO. DPR-45 DOCKET NO. 50-409 1.0 REGULATORY LIMITS 1.1 Airborne Effluent Release Limits:

LACBWR airborne particulates, with half-lives greater than 8 days, released to areas beyond the Effluent Release Boundary shall be limiteq to</= 7.5 mRem to

. any organ per calendar quarter and </= to 15 mR~m to any organ per calendar year.

Also, in accordance with the provisions of 40 CFR 190, the restrictions for total dose to any member o~ the public from all LACBWR related sources and d.ose pathways are evaluated quarterly and on an arinual basis.

1.2 Liquid Effluent Release Limits:

LACBWR's liquid effluent release limitations are those concentrations specified in 10 CFR 20 Appendix B, Table 2, Column 2. The values reported in Tables 2A and 28, Liquid Effluents (this report), are based on dilution of the effluent with the.

Genoa Station No. 3 condenser cooling water flow prior to discharge to the Mississippi River. No credit is taken for further dilution in the mixing zone of the Mississippi River.

Also, in accordance with 10 CFR 50, Appendix I, the dose commitment to a member of the public from radioactive materials released in liquid effluents to 2

~-"- -

  • -'~"'~ -* -,....-- ----

EFFLUENT AND WASTE DISPOSAL REPORT areas beyond the Effluent Release Boundary are limited to less than 1.5 mRem whole body and 5.0 mRem organ dose per calendar quarter, and less than 3.0 mRem whole body and 10 mRem organ dose per calendar year via the critical ingestion pathway.

In accordance with the provisions of 40 CFR 190, the restrictions for total dose to any member of the public from all LACBWR related sources and dose pathways are evaluated quarterly and on an annual basis.

1.3 Solid Radioactive Waste All solid radioactive wastes are handled in accordance with a Process Control

  • Program as defined by LaCrosseSolutions, LLC procedures, in order to assure that all applicable transportation and burial site disposal requirements are met.

3

EFFLUENT AND WASTE DISPOSAL REPORT 2.0 EFFLUENT RELEASE CONCENTRATION LIMIT The Effluent Release Concentration used to calculate permissible release rates are obtained from 10 CFR 20, Appendix B, Table 2, Column 2.

3.0 AVERAGE ENERGY The release rate limits for LACBWR are not based on average energy.

4.0 ANALYTICAL METHODS 4.1 Liquid Effluents Liquid effluent measurements for gross radioactivity are performed by HPGe gamma isotopic analysis of a representative sample from each tank prior to discharge. In addition, each batch discharge tank sample is analyzed for alpha and tritium activity concentrations using site approved bench top analysis equipment. A composite sample is created by collecting representative aliquots from each tank batch discharged during a calendar quarter. This composite is analyzed for lron-55 and Strontium-90 by an off-site contractor on a quarterly basis.

4.2Airborne Particulates Airborne particulate releases are determined by HPGe gamma isotopic analysis and gross beta analyses of glass fiber filter paper taken from low volume air samplers. The air samplers either continuously monitor the air from areas outside of the RCA or low volume air monitors are specifically set up in predominant downwind pattern locations outside the RCA, for evaluation of outside work activities during decommissioning work. This filter is changed and analyzed on an approximate bi-4

EFFLUENT AND WASTE DISPOSAL REPORT weekly basis and typically analyzed approximately 7 days after removal, to minimize interference from radon progeny. The glass fiber filters are also analyzed for alpha activity for outside work activities during decommissioning activitie~.

5.0 BATCH RELEASES 5.1 Airborne The LACBWR stack was not operated during CY 2016 and therefore there were no stack airborne releases. In fact, during the start of decommissioning the stack dismantlement was initiated. Routine low volume air sampling was initiated in July of 2016 at four locations outside the RCA in the predominant typical downwind locations, to be used for environmental monitoring purposes. Two of the environmental air monitors are located on the DPC site and two monitors are located off site, collocated with State of Wisconsin environmental air samplers.

The two air monitors located on the DPC site are also used for routine ~valuation of potential ground level type releases due to site decommissioning work. There were no outside work activities during the calendar year such as significant facility demolition or operation of HEPA exhaust systems to outside areas that warranted the set-up of additional low volume air monitoring.equipment to evaluate ground level type releases.

5.2 Liquid All liquid effluent releases at LACBWR are batch releases as described in the ODCM. This is summarized as follows:

5

EFFLUENT AND WASTE DISPOSAL REPORT

( 1)

Number of Batch Releases:

30 (2)

Total Time Period for Batch Releases:

157.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> (3)

Maximum Time Period for a Batch Release:

8.0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> (4)

Average Time Period for a Batch Release:

5.24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (5)

Minimum Time Period for a Batch Release:

1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> (6)

Average Stream Flow Rate During Periods of Release of Effluent into a Flowing Stream:

90,000 tt3/sec

  • 6.0 ABNORMAL RELEASES There were no abnormal releases of radioactivity in plant effluents.

7.0 ESTIMATED TOTAL ANALYTICAL ERROR The reported analytical results contain the following estimated errors:

Counting Error 95% Confidence Level Sampling Voiume Error+/- 5%.

6

A.

1.
2.
3.

B.

1.

EFFLUENT AND WASTE DISPOSAL REPORT TABLE1A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2016 AIRBORNE PARTCULATE EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR 1 QTR2 QTR3 QTR4 PARTICULATES BETA-GAMMA PARTICULATES WITH HALF-LIVES> 8 DAYS Ci 0

0 0

0 AVERAGE RELEASE RATE FOR PERIOD

µCi/ Sec 0

0 0

0 GROSS ALPHA RADIOACTIVITY Ci 0

0 0

0 PERCENTAGE OF ODCM DOSE LIMITS FOR PARTICULATE EFFLUENT RELEASES QTR QTR QTR QTR ALL RADIONUCLIDES IN PARTICULATE FORM WITH HALF-LIVES GREATER THAN 8DAYS Highest Organ % Limit 0

0 0

0 7

TOTAL 0

0 YEARLY 0

EFFLUENT AND WASTE DISPOSAL REPORT TABLE 1B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2016 AIRBORNE PATICULATE EFFLUENTS -GROUND LEVEL RELEASE CONTINUOUS OR BATCH MODE UNIT QTR QTR QTR QTR NUCLIDES RELEASED 1;

PARTICULATES, Gross Alpha Ci 0

0 0

0 CESIUM-134 Ci 0

0 0

0 CESIUM-137 Ci 0

0 0

0 COBALT-60 Ci 0

0 0

0 MANGANESE-54 Ci 0

0 0

0 ZINC-65 Ci 0

0 0

0

.TOTALS Ci 0

0 0

0

--~- ----

8 TOTAL 0

0 0

0 0

0 0

EFFLUENT AND WASTE DISPOSAL REPORT TABLE 2A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2016 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR QTR I QTR QTR TOTAL A

FISSION & ACTIVATION PRODUCTS

1.

TOT AL RELEASE (NOT INCL.

Ci 1.SOE-04 7.44 E-04 1.48E-03 8.11 E-05 2.46E-03 TRITIUM, GASES, ALPHA)

2.

AVERAGE DILUTED

µCi/ml 1.20E-10 5.68E-09 8.77E-10 2.92E-09 CONCENTRATION DURING PERIOD B.

TRITIUM*

1.

TOT AL RELEASE Ci 6.11 E-06 5.04E-04 1.01 E-04 1.63E-05 6.27E-04 AVERAGE DILUTED

µCi/ml 5.44E-11 2.49E-08 6.04E-10 4.34E-09 CONCENTRATION DURING PERIOD

c.

DISSOLVED AND ENTRAINED GASES - no releases - no longer analyzed for.

D.

GROSS ALPHA RADIOACTIVITY

1.

TOT AL RELEASE Ci 1.33E-06 7.27E-07 4.0?E-06 2.49E-06 8.61 E-06 E.

VOLUME OF WASTE Liters 1.78E+04 4.85E+03 1.89E+05 9.93E+4 3.11 E+OS RELEASED {PRIOR TO DILUTION)

F.. VOLUME OF DILUTION".

Liters 1.12E+08 2.02E+07 1.66E+08 3.65E+06 3.02E+08 WATER USED DURING PERIOD G.

PERCENTAGE OF ODCM LIMITS FOR LIQUID RELEASES QTR QTR QTR QTR YEARLY HIGHEST ORGAN 0.13%

0.78%

8.14%

14.64%

11.84%

WHOLE BODY 0.24%

1.65%

17.46%

13.23%

16.29%

9

-- - __ ::.:_::_::__-_:._ _____ -::_.....:.__~----~-

-*-----~-

--~--*-----*-----*---

EFFLUENT AND WASTE DISPOSAL REPORT TABLE 28 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2016 LIQUID EFFLUENTS NUCLIDES RELEASED UNIT QTR~1 QTR.:2

  • QTR-3.

QTR-4.

MN-54 Ci 0.0 0.0 0.0 0.0 IRON -55 Ci 0.0 0.0 0.0 0.0 ZINC-65 Ci 0.0 0.0 0.0 0.0 COBALT-60 Ci 1.02E-05 1.58E-06 1.02E-05 1.58E-06 STRONTIUM-90 Ci 4.25E-05 1.90E-05 9.51E-05 6.65E-05 CESIUM-137 Ci 8.67E-05 7.23E-04 1.37E-03.

1.30E-05 CESIUM-134 Ci 0.0 0.0 0.0 0.0 TOTAL FOR PERIOD (ABOVE)

Ci 1.50E-04 7.44E-04 1.48F03 8.11 E-05 10

EFFLUENT AND WASTE DISPOSAL REPORT TABLE 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT - 2016 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

SOLID WASTE SHIPPED OFFSITE FOR DISPOSAL (Not Irradiated Fuel)

1. TYPE OF WASTE UNIT 1st 6-MONTH 2"ct 6-MONTH TOTAL
  • . PERJOD PERIOD
a. Spent resins, filter sludges, evaporator bottoms*, etc.
b. Dry compressible waste, contaminated equipment, etc.
c. Irradiated components, control rods, etc.
d. Other
2. ESTIMATE OF MAJOR NUCLIOE COMPOSITION (BY TYPE OF WASTE)

Cs-137 Fe-55 Ni-63 Pu-241 Co-60

3.

SOLID WASTE DISPOSITION m3 Ci m3 Ci

. m 3 Ci m3 Ci

. PERCENT.*

'TOTAL 50 22 13 8

3 MODE OF 0

0 0

0 0.00 508.4 0.00 0.413

'0.00 0

0.00 0

0 0.00 0

0.00 1st :

2~d 6-MONTH

,. 6~MONTH

  • PERfOD
  • .PERlbb..

0 0

508 0.413 0

0 0

0 Es~imat~d

  • Error*

Values.

CURIES **

CURIES.

0 0.206

+t-10 0

0.090

+/- 10 0

0.053

+/- 10 0

0.034

+/- 10

.0 0.011

+/- 10 NO. OF SHIPMENTS TRANSPORTATION DESTINATION 23 Rail B.

IRRADIATED FUEL SHIPMENTS (DISPOSITION)

NO OF SHIPMENTS NONE MODE OF TRANSPORTATION 11 Clive, UT DESTINATION

EFFLUENT AND WASTE DISPOSAL REPORT 8.0 OFFSITE DOSE CALCULATIONS

SUMMARY

AND CONCLUSIONS:

Particulate Effluent Releases The maximum quarterly offsite dose to any organ from the release of all radionuclides in particulate form with half-lives greater than 8 days was 0 mRem.

The cumulative 2016 annual maximum organ dose from these radionuclides was also 0 mRem.

8.1 Liquid Effluent Releases The maximum quarterly organ dose from liquid releases was approximately 7.32E-01mRem. The cumulative 2016 annual organ dose was approximately 1.18mR~m. The maximum quarterly*total body dose for liquid releases was approximately 2.62E-01 mRem, and the* cumulative 2016 annual total body dose was approximately 4.89E-01 mRem.

12

-* -*--=--*~---=--- ---~----

EFFLUENT AND WASTE DISPOSAL REPORT 8.2 Conclusion All calculated offsite doses were below ODCM limits.

9.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) REVIEW LaCrosseSolutions issued Revision 0 and Revision1 to the ODCM with Revision 1 issued in August of 2016. The majority of the changes in Revision 1 were made to reflect the changes in the related environmental program and procedural

. documents which involved the addition of ambient direct radiation monitoring and environmental air sampling requirements.

10.0 PROCESS CONTROL PROGRAM (PCP) REVIEW The LaCrosseSolutions PCP was issued as Revision 0 in November of 2016.

The PCP a.ddresses the waste management administrative and operational controls to be used by LaCrosseSolutions during the course of the decommissioning work to ensure the final waste product meets requirements of applicable federal, state, and disposal site waste requirements.

13

SECTION B ANNUAL RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT 1

    • -_::::::___: ___ ~---* **-*~"--

--~*

--~--- ----- -----------------

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT INTRODUCTION:

The Radiological Environmental Monitoring (REM) Program is conducted to comply with the requirements of the ODCM and in accordance with 10 CFR 50 Part 50.36a and 10 CFR 72.104. The REM Program provides measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides which could potentially lead to radiation doses to Members of the Public resulting from plant effluents. Environmental samples are taken within the surrounding areas of the plant and in selected control or background locations.

The monitoring program at the LACBWR facility includes monitoring of liquid and airborne particulate releases from the plant, as well as collecting environmental samples of surface air, river water, river sediment, and ambient radiation.

The REM program therefore supplements the Radioactive* Effluent analyses by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and modeling of the environmental exposure pathways using the methodology of the Offsite Dose Calculation Manual (ODCM).

An lnterlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental samples are performed.

1

--- ---= -___ :..... __ :.:_-: _____ - ----*---

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT 1.0 SAMPLE COLLECTION Environmental samples are collected from the area surrounding LACBWR at the frequencies outlined in the ODCM and the Environmental Monitoring Program. A series of figures and tables are included in this report to explain the LACBWR environmental program.

FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8 TABLE 9 TABLE 10 This map includes the plant exclusion boundary, roads, other generation plants, and the relationship of the plant to the nearest local community.

This map shows the location of the LACBWR RCA Fence Line Area Environmental TLD Locations.

These maps show the location of environmental low volume air sampler locations.

This map shows the location of ISFSI environmental TLDs.

This table logs the environmental TLD locations at the ISFSI.

This table shows the sampling frequency of the various environmental samples and the analyses performed on these samples This table shows the environmental air monitoring stations

. used in LACBWR's environmental program.

This table logs the LACBWR environmental TLD locations.

This table shows the number of various samples collected and analyzed during 2016.

Quarterly Environmental TLD results for RCA Area around LACBWR Bi-Weekly Gross Beta Env. Air Sample Analysis Results 2

. *~-~ : - -- - =------ _-_: ___ : ______________ ;__: -- ---------

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 11 TABLE 12 TABLE 13 TABLE 14 Bi-weekly Gamma Spec Env. Air Sample Analysis Results Semi Annual Mississippi River Water Analysis Results Semi Annual Mississippi River Sediment Analysis Results Quarterly Environmental TLD results for ISFSI Area 2.0 RESULTS OF THE 2016 RADIO-ENVIRONMENTAL MONITORING SURVEYS During 2016, activity levels in the local environment were normal, indicating no significant plant attributed radioactivity.

3

  • -------~ ----~--~---------------

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT 2.1 PENETRATING RADIATION The environmental penetrating radiation dose is measured by environmental TLDs.

2.1.1 LACBWR Plant - These environmental TLDs were changed on a quarterly basis starting in July 2016. The results for the LACBWR Plant from 2016 are shown on Table 9.

2.1.2 ISFSI - These environmental TLDs are changed on a quarterly basis. Table 14 results for 2016 are shown.

2.2 AIR PARTICULATE Air samples were collected continuously from various sites (see Table 3) around LACBWR.

Low volume particulate air samplers were used to collect air samples. The air filter consists of a glass fiber filter with an associated pore size of approximately 0.45 µm. The particulate filters were analyzed bi-weekly for gross beta activity with an internal proportional counter, as well as analyzed by gamma spectroscopy for individual isotopic concentration.

TABLE 1 O This table shows the bi:. weekly gross beta gamma activity concentration from the air particulate filters.

TABLE 11 This table *shows the individual air sample particulate isotopic analysis results.

2.3 RIVER WATER River water is collected semi-annually. River water samples before the intake structure, at plant outfall, and below the plant outfall 4

'--~ *:-_

...:___:;~ -~ - ~~~-~~-- ---

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT are collected and are gamma analyzed for isotopic concentration and tritium analysis. The river water gamma isotopic analysis results are shown in Table 12.

The results indicate that there were no significant plant attributable *radionuclides in the river water.

2.4 SEDIMENT SAMPLES Sediment samples are collected semi-annually before the intake structure, at plant outfall, and below the plant outfall. These samples are gamma analyzed and these results appear on Table 13. They indicated that small amounts of plant-attributed radionuclides have accumulated in river sediments near the outfall. The amount of radionuclides in the sediment have declined significantly after plant shutdown. These amounts have remained relatively constant the last few years.

3.0 CONCLUSION

S All environmental samples collected and analyzed during 2016 exhibited no significant contribution from LACBWR or ISFSI.

5


_,: --=.:::..... -~---- __ ::_ ---=-------= -~*; ___ _:__ ---

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT 4.0 INTERLABORATORY COMPARISON PROGRAM RESULTS During 2016, interlaboratory comparison samples were obtained from an outside contractor. The equipment used to analyze the environmental samples was tested again~t the contractors' results. The following are the results of these comparisons.

'ANALYSIS' GROSS BETA GROSS ALPHA 1-131 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 H-3 LACBWR RES UL TS 243 pCi 101 pCi 99 pCi/I 295 pCi/I 159 pCi/I 188 pCi/I 153 pCi/I 142 pCi/I 139 pCi/I 281 pCi/I 189 pCi/I 13000 pCi/I 6

-- __ -_-::_.::::_-...:::.* ___. ~

-CONTRACTOR RES UL TS 232 pCi 116 pCi 91.8 pCi/I 271 pCi/I 173 pCi/I 122 pCi/I 142 pCi/I 125 pCi/I 121 pCi/I 236 pCi/I 172 pCi/I 11900 pCi/I RATIO 1.05 0.87 1.08 1.09 0.92 1.54 1.08 1.13 1.15 1.19 1.10 1.10

~ -* -

-~~-

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT LOCATION-MAP SCALE OF FEET

  • r.:1oi:ri.R.~:s:w.

OF THE 5th P.M.

  • JEFFERSON TOWNSHIP HOUSTON COUNTY, MINNESOTA SEC. 7

-s£C..1s LOT 7 NOTl* ISLAND IH IS UNOUI Tit£

.IUIUS DICTIOIC OI' UPPU IUS.SISSIPPI lllV[R WILO INEUCATU

'-'ILlS &aovt '"l UF[ ANO FISH ll[FUG[. l "1tOUT" OF lMl 'OHIO RIVER.

f VILLAfJE 0,

r~.!!~.~_j GENOA LOT~

29 28

~~-

LOT 4 ElQ.USION BOUHDIU 1109 ft 1'&c!ifu WEU T.-1!-N. I R.-7-W.

s OF THE 411h P.M.

oTOWN OF GENO~

VERNON COUNTY, WISCONSIN WELL FIGURE 1 - LACBWR PROPERTY MAP 7

~-*_..___..:::__.::_,_ ______ *. -~--*- --- --

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT AJ>HI rns:r,,.,.no.v f

.SCev,,,1y4 v / t.. O.

~AHKCVSU/ I (


::;-\\\\I '/U /?'di/Se 'fit PHH£ NPVSc

  1. 3 I

. ~

0 EJJ:.'c Y~I SWlrtlf Yl'RD

,.,T.D

"""" 1--------+---'

o~

7&

_J FIGURE 2 - LACBWR RCA FENCE LINE ENVIRONMENTAL TLD LOCATIONS 8

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT LOCATION-MAP 1000 100,

o

..,...,...._~

~ I tra' SCALE OF FEET r.:1oi~ti, R.:3:w.

OF THE 5th P.M.

  • JEFFERSON TOWNSHIP HOUSTON COUNTY, MINNESOTA SEC. 7 SEC *. 18

-. I LOT 7

"'OTt

  • ISLAND 126 IS UNDUI THE

.IURISDICTION OF U"Plll Ml~llSSIPPI ftlV[ll Wl1.0 1ND1cut.s.,.,Lts uovt tKC urc ~o FISH llCFVGC. I MOUHI OF ltt[ OttlQ li1V£.R.

\\

LOT\\-

H"2B 32 33 LOT 4 EXCLUSION Ba.nm.\\r 1109 ft HdiU!

'It WELL LIMITS T.-13-N., R.-7-YJ.

OF THE 4th P.M.

oTOWN OF GENO~

VERNON COUNTY\\

WISCONSIN 1l'.

WELL FIGURE 3 - LACBWR ENVIRONMENTAL LOW VOLUME AIR SAMPLER LOCATIONS 9

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT CDIL PJUFDICI------...._

/

CUllD __

//

I I

t I

I I

I

/

\\0

\\

/

/

/

\\

\\

I t

I I

I

. I I

I


- "" "-.WG:I.£...a ITl'1DI DI SI D

FIGURE 4-ISFSI ENVIRONMENTAL TLD LOCATIONS 10 I

  • i

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 4 ISFSI ENVIRONMENTAL DIRECT RADIATION BADGE LOCATIONS

  • LOCATION*

-'NO.:.

. r:

-r

  • 1
  • L0CA TION

"'"J*_,_.

~

.,o. 1 1

ISFSI ADMINISTRATIVE BUILDING WEST 2

ISFSI PROTECTED AREA NORTH EAST SIDE 3

ISFSI PROTECTED AREA NORTH WEST SIDE 4

ISFSI PROTECTED AREASOUTH WEST SIDE 5

ISFSI PROTECTED AREA SOUTH EAST SIDE 6

ISFSI OWNER Controlled FENCE NORTH 7

ISFSI OWNER CONTROLLED FENCE WEST 8

ISFSI OWNER CONTROLLED FENCE EAST 9

ISFSI OWNER CONTROLLED FENCE NORTH EAST BY HEAVY HALL PATH 10 ISFSI OWNER CONTROLLED FENCE WEST BY BOAT LANDING 11

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 5 SAMPLE FREQUENCY AND ANALYSIS OF RADIOLOGICAL ENVIRONMENTAL SAMPLES SAMPLE..

  • FREQUENCY

~ANAL YSIS,PERFORMED **.

('. -

~..

Environmental TLDs Quarterly Dose in mRem Particulate Air - Glass Bi-Weekly Gross Beta and Gamma Fiber Filters Spectroscopy River Sediment Semi-annually Gamma Spectroscopy River Water Semi-annually Gamma Spectroscopy and Tritium (Liquid Scintillation Analyzer) 12

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 6 LOW VOLUME ENVIRONMENTAL AIR MONITORING STATION LOCATIONS (Refer to Figure 3)

LOCATIO.N.

LI

. NO:"

LO.CATION,.

o n

1 Trailer Park 2

Coal Plant - North Side 3

SW of Main Switch Yard 4

Lock and Dam #8 - North Side 13

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 7 LACBWRENVIRONMENTAL TLD LOCATIONS 2

RCA FENCE LINE NORTH 3

RCA FENCELINE SOUTHEAST 4

RCA FENCELINE SOUTH 5

RCA FENCE LINE SOUTHWEST.

6 RCA FENCE LINE WEST 14

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 8 RADIOLOGICAL ENVIRONMENTAL SAMPLES COLLECTED JANUARY-DECEMBER 2016 NUMBER OF

. TYPE OF SAMPLE

  • SAMPLES.

Penetrating Radiation(Environmental TLDs) 52 Air Particulate 52 River Water

.6 River Sediment 6

15

RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT TABLE 9 QUARTERLY ENVIRONMENTAL TLD RESULTS IN THE LACBWR VICINITY JULY-DECEMBER 2016 BACKGROUND AND OCCUPANCY FACTOR CORRECTED STATION 1st QUARTER 2nd QUARTER 3rd QUARTER 4th QUARTER NO.

mRem mRem mRem

  • mRem 1

N/A N/A 0.1 0.1 2

N/A N/A 0.0 0.1 3

N/A N/A 0.0 0.1 4

N/A N/A 0.1 0.2 5

N/A N/A 0.0 0.1 6

N/A N/A 0.0 0.1 16

TABLE 10 Bl-WEEKLY GROSS BETA AIR PARTICULATES IN THE LACBWR VICINITY

,l

    • . *~

SW MAIN*

.CO~LECTION COAL PLANT TRAILER COURT LOCK AND DAM #8.

SWITCHYARD DATE pCi/m3.

~* pCi/~3

' pCi/m3 pCi/m3.

7/21/2016

.019 +/-.004

.016 +/-.004

.019 +/-.004

.017 +/-.004 8/3/2106

.024 +/-.003

.017 +/-.003

.016 +/-.003

.028 +/-.003 8/17/2016

.022 +/-.003

.019 +/-.003

.023 +/-.003

.026 +/-.003 8/31/2016

.024 +/-.002

.017 +/-.002

.019 +/-.002

.025 +/-.002 9/14/2016

.018 +/-.002

.015 +/-.002

.020 +/-.002

.022 +/-.002.

9/28/2016

. 018 +/-.002

.017 +/-.002

.016 +/-.002

.023 +/-.002 10/12/2016

.021 +/-.002

.018 +/-.002

.019 +/-.002

.020 +/-.002 10/26/2016

.018 +/-.002

.016 +/-.002

.018 +/-.002

.016 +/-.002 11/9/2016

.026 +/-.002.

.024 +/-.001

.025 +/-.002

.021 +/-.002 11/23/2016

.025 +/-.001

.024 +/-.001 NO DATA-POWER

.025 +/-.001 INTERRUPTION 1217/2016

.027 +/-.002

.020 +/-.001

.024 +/-.002

.024 +/-.002 12/21/2016

.019 +/-.002

.016 +/-.001

.018 +/-.003

.030 +/-.002 17

LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 TABLE 11 Bl-WEEKLY AIR SAMPLE GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

COAL PLANT TRAILER COURT LOCK AND DAM SW MAIN

  1. 8 SWITCHYARD 70/16 1n116 1n116 1n116 7/21/16 7/21/16 7/21/16 7/21/16

< 6.50 E-03

< 4.03 E-03

< 8.04 E-03

< 2.92 E-03

< 7.15 E-03

< 1.75 E-03

< 5.85 E-03

< 3.13 E-03

< 6.82 E-03

< 3.60 E-03

< 8.99 E-03

< 1.86 E-03 COAL PLANT TRAILER COURT LOCK AND DAM.

SW MAIN

  1. 8 SWITCHYARD 7/21/16 7/21/16 7/21/16 7/21/16 8/3/16 8/3/16 8/3/16 8/3/16

< 4.05 E-03

< 1.78 E-03

< 4.04 E-03

< 3.37 E-03

< 4.29 E-03

< 1.94 E-03

< 4.23 E-03

< 3.58 E-03

< 4.25 E-03

< 1.87 E-03

< 4.17 E'-03

< 2.25 E-03 18

LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 TABLE 11 Bl-WEEKLY AIR SAMPLE GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

COAL PLANT TRAILER COURT LOCK AND DAM SW MAIN

  1. 8 SWITCHYARD 8/3/16 8/3/17 8/3/16 8/3/16 8/17/16 8/17/17 8/17/16 8/17/16

< 6.65 E-03

. < 1.67 E-03

< 3.71 E-03

< 2.32 E-03

< 6.92 E-03

< 1.68 E-03

< 3.94 E-03

< 2.54 E-03

< 7.07 E-03

< 1.67 E-03

< 3.92 E-03

< 2.64 E-03 COAL PLANT TRAILER COURT LOCK AND DAM#8 SW MAIN SWICHYARD 8/17/16 8/17/164 8/17/16 8/17/16 8/31/16 8/31/16 8/31/16 8/31/16

< 3.70 E-03

< 1.62 E-03

< 3.63 E-03

< 3.21.E-03

< 3.86 E-03

< 1.79 E-03

< 3.95 E-03

< 3.39 E-03

< 2.53 E-03

< 1.24 E-03

< 3.90 E-03

< 3.35 E.,03 19

TABLE 11:

81..:WEEKL Y AIR SAMPLE *GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

LOCATION COAL PLANT TRAILER COURT LOCK AND DAM SW MAIN

  1. 8 SWITCHYARD START DATE 8/31/16 8/31/16 8/31/16 8/31/16 END DATE 9/14/16 9/14/16 9/14/16 9/14/16 ISOTOPES Cs-134

< 3.65 E-03

< 1.62 E-03

< 3.53. E-03

< 3.09E-03 Cs-137

< 3.84 E-03

< 1.77E-03

< 3.80 E-03

< 3.22 E-03 Co-60

< 3.93E-03

< 1.77E-03

< 3.81E-03

< 3.33E-03 LOCATION

  • COAL PLANT TRAILER COURT LOCK AND DAM#S SW MAIN SWITCHYARD START DATE 9/14/16 9/14/16 9/14/16 9/14/16 END DATE 9/28/16 9/28/16.

9/28/16 9/28/16 ISOTOPES/RL

  • Cs-134

< 3.69 E-03

< 1.65 E-03

< 3.77 E-03

< 3.08 E-03 Cs-137

< 3.86 E-03

< 1.77 E-03

< 3.94 E-03

< 3.34 E-03 Co-60

< 3.88 E-03

< 1.08 E-03

< 3.96 E-03

< 3.25 E-03 20

LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 TABLE 11 Bl-WEEKLY AIR SAMPLE GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

COAL PLANT TRAILER COURT LOCK AND DAM SW MAIN

  1. 8 SWITCHYARD 9/28/16 9/28/16 9/28/16 9/28/16 10/12/16 10/12/16 10/12/16 10/12/16

< 3.57 E-03

< 1.62 E-03

< 3.77 E-03

< 3.25 E-03

< 5.01E-03

< 1.53E-03

< 3.78 E-03 2.42 E-3 +/- 3.94 E-4

< 3.92E-03

< 1.11 E-03

< 2.38 E-03

< 3.40 E-03 COAL PLANT TRAILER COURT LOCK AND DAM #

SW MAIN SWITCHYARD 10/12i16 10/12/16 10/12/16 10/12/16 10/26/16 10/26/16 10/26/16 10/26/16

< 3.64 E-03

< 1.78 E-03

< 3.70 E-03

< 3.05 E-03

< 3.90 E-03

< 1.72E-03

< 3.75 E-03

< 3.17E-03

< 3.89 E-03

< 1.87E-03

< 2.90E-03

< 3.33 E-03 21

LOCATION START DATE*

END DATE ISOTOPES Cs-134 Cs-137 Co-60 LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 TABLE 11 Bl~WEEKL Y AIR SAMPLE GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

COAL PLANT TRAILER COURT LOCK AND DAM # SW MAIN SWITCHYARD 10/26/16 10/26/16 10/26/16 10/26/16 11/9/16 11/9/16 11/9/16 11/9/16

< 3.87 E-03

< 1.78 E-03

< 3.80 E-03

< 3.22 E-03

< 3.85 E-03

< 1.79 E-03

< 3.94 E-03

< 3.32 E-03

< 3.90 E-03

< 1.73 E-03

< 4.00 E-03

< 3.39 E-03 COAL PLANT TRAILER COURT LOCK AND DAM#S SW MAIN SWICHYARD 11/9/16 11/9/16 11/9/16 11/9/16 11/23/16 11/23/16 11/23/16 11/23/16

< 3.89 E-03

< 1.76 E-03 NO DATA-POWER < 3.17 E-3 INTERRUPTION

< 3.99 E-03

< 1.84 E-03

< 3.55 E-03

< 4.08 E-03

< 1.71 E-03

< 3.43 E-03 22

LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 LOCATION START DATE END DATE ISOTOPES Cs-134 Cs-137 Co-60 TABLE 11 Bl-WEEKLY AIR SAMPLE GAMMA SPECTROSCOPY RESULTS (Concentrations in pCi/m3)

COAL PLANT TRAILER COURT LOCK AND DAM#S SW MAIN SWICHYARD 11/23/16 11/23/16 11/23/16 11/23/16 12/7/16 12/7/16 12/7/16 12/7/16

< 3.68 E-03

< 4.20 E-03

< 3.99 E-03

< 3.07 E-03

< 3.89 E-03

< 1.77 E-03

< 4.36 E-03

< 3.34 E-03

< 2.57 E-03

< 1.74 E-03

< 4.46 E-03

< 2.14 E-03 COAL PLANT TRAILER COURT LOCK AND DAM#S SW MAIN SWICHYARD 12/7/16 12/7/16

. 12/7/16 12/7/16 12/21/16 12/21/16 12/21/1$

12/21/16

< 3.67 E-03

< 1.77 E-03

<4.19E-03

< 3.15 E-03.

< 3.96 E-03

< 1.78 E-03

<4.12E-03

< 3.40 E-03

< 4.03 E-03

< 1.77 E-03

< 4.12 E-03

< 3.25 E-03 23

TABLE 12 RESULTS OF ANALYSIS OF MISSISSIPPI RIVER WATER IN THE VICINITY OF LACBWR (Concentrations in pCi/Liter)

SAMPLE #1 SAMPLE#2 SAMPLE #3 SAMPLE #1 SAMPLE #2 SAMPLE#3 COLLECTION DATE:

LOCK and LACBWR VICTORY, WI LOCK and LACBWR VICTORY, WI SAMPLE LOCATION:

DAM#8 OUTFALL 4/27/16 DAM#8 OUTFALL 10/17/16 4/27/16 4/27/16 10/17/16 10/17/16 ISOTOPES/RL

  • H-3 671 +/- 168 630 +/- 164 844 +/- 220 333 +/- 95 309 +/- 95 380 +/- 96 Mn-54/1000

< 4.14

< 4.15

< 4.16

< 4.10

< 4.16

< 4.18 Co-601300

< 4.45

< 4.32

< 4.31

< 4.34

< 4.46

< 4.39 Zn-65/300

< 8.51

< 8.90

< 9.20

< 9.12

< 9.13

< 9.10 Cs-134/30

< 4.68

< 4.46

< 4.67

< 4.64

< 4.77

< 4.60 Cs-137/50

< 4.60

< 2.67

< 2.94

< 3.24

< 4.51

< 2.91 RL = REPORTING LEVEL 24

TABLE13 RESULTS OF ANALYSIS OF MISSISSIPPI RIVER SEDIMENT IN THE VICINITY OF LACBWR (Concentration in pCi/Kg)

SAMPLE LOCATION UPSTREAM OUTFALL DOWNSTREAM UPSTREAM OUTFALL DOWNSTREAM COLLECTION DATE 04/27/16 04/27/16 04/27/16 10/13/16 10/13/16 10/13/16 ISOTOPES Cs-134

< 6.42

< 4.91

< 9.35

< 6.17

< 5.74

< 9.59 Cs-137 11.7 +/-.98 191+/-5.51 37.0 +/- 1.74 5.91 +/- 0.28 24.7 +/- 1.02 64.5 +/- 2.58 Co-60

< 6.06 4.49 +/- 0.44

< 8.77

< 5.73

< 5.39

< 8.96 25

TABLE14 QUARTERLY ENVIRONMENTAL DOSIMETER DOSE MEASUREMENTS IN THE ISFSI VICINITY JANUARY-DECEMBER 2016 BACKGROUND AND OCCUPANCY FACTOR CORRECTED*

STATION NO.

1st QUARTER 2nd QUARTER 3rd QUARTER 4th QUARTER mRem mRem mRem mRem 1

0.0 0.0 0.0 0.0 2

37.5 43.2 36.2 41.7 3

1oe.5 119.7 122.2 112.2 4

19.4 26.8 24.5 24.2 5

33.6 46.4 44.0 41.5 6

0.0 0.0 0.0 0.0 7

0.0 0.0 0.0 0.0 8

0.0 0.0 0.1 0.0 9

0.0 0.0 0.0 0.0 10 0.0 0.0 0.1 0.0

  • Occupancy Factor Applied to Owner Controlled Area Fence Line Only 26

LaCrosseSolutions LC-2017-0016: Attachments LACBWR Offsite Dose Calculation Manual

LaCrosseSolutions LC-2017-0016: Attachments LACBWR Process Control Program

-~

LACR~SOWTIONS Preparer (Print name/Sign)

LACBWR Site Restoration Project Process Control Program Procedure No. LC-WM-PG-001 Revision No. 0 Secondary Reviewer (Print Name/Sign) Joe.. L); oe. *&t, vJL.0:,a_

(}

Date:

UL 1 Lt~

Regulatory Required Reviews (attach completed LC-RA-PR-001 and QTR forms, as applicable)

Part 50 License: 10 CFR 50.59 and 50.90 181 YES D NO Fire Protection: I 0 CFR 50.48(f)

DYES

[gj NO Conditions of License: PSP: 10 CFR 50.54(p)

DYES 181 NO Conditions of License: E-Plan: 10 CFR 50.54(q)

DYES

[gj NO Termination of License: 10 CFR 50.82(a)(6) and 50.82(a)(7)

DYES 181 NO Part 72 License: 10 CFR 72.48 DYES 181 NO Program Required Reviews RP:

181 YES o No s1GNATUREG. Peterschmldt _:il- ;;;:::::;A1ATE:

,. (i Jft,.

QA: 0 YES [8J NO SIGNATURE. ____________ DATE:. ___

.......LJ--ti'I

/\\. ~

QTR: 181 YES 0 NO SIGNATURE. ___

.x.J UJ_U._-4 ____

___;._DATE: 11/07/20 I 6 Approval Section Effective Date: I)/~{; Lo (assigned by ocument Control or Project Manager)

Process Control Program TABLE OF CONTENTS LC-WM-PG-001 Revision 0

1.

PURPOSE AND SCOPE....................................................................................................... 3 1.1.

Purpose............................................................................................... '......................... 3 1.2.

Scope........................................................................................................................... 3

2.

REFERENCES.................................... ~.................................................................................. 3 2.1.

NRC, Title 10, Part 61, "Licensing Requirements for Land Disposal of Radioactive Waste".,.................................. :..................................................................................... 3 2.2.

NRC, Title 10, Part 20, "Standards for Protection Against Radiation"......... :............ 3 2.3.

NRC, Title 10, Part 71, "Packaging and Transportation of Radioactive Material".... 3 2.4.

DOT, Title 49, "Transportation", Sub Chapter C - "Hazardous Materials Regulations", Part 173, "Shippers - General Requirements for Shipments."............ 3 2.5.

NRC, Regulatory Guide 1.143,."Design Guidance for Radioactive Waste Management Systems, Structures, and Components Installed in Light-Water-Cooled Nuclear Power Plants"......... :...................................................................................... 3 2.6.

Amendment# 72 to License DPR-45, Lacrosse Permanently Defueled Technical Specifications (POTS)................................................................................................ 3 2.7.

NRC, Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants"...................................... 3 2.8.

LaCrosseSolutions, proc~dure LC-RP-PR-025, "Generation of the Annual Radioactive Effluent Release Report (ARERR)".......................................................3 2.9.

NRC Branch Technical Position On "Concentration Averaging and Encapsulation",

dated January 1995..................................................................,.................................. 3 2.10.

NRC Branch Technical Position On "Waste.Form", Revision 1, dated January 19913

3.

GENERAL............................................................................................................................... 4 3.1.

Responsibilities........................................................ _......................................... ;......... 4 3.2.

Definitions...................................................................................-................................ 4 3.3.

LACBWR.Site Restoration Project Planned Activities.............................................. 5 3.4.

Process Control Program Administration................................................................... 5 Page 2 of7

Process Control Program

1.

PURPOSE AND SCOPE 1.1.

Purpose LC-WM-PG-001 Revision 0 This Process Control Program (PCP) identifies the administrative and operation controls for waste processing, process parameters, and surveillance requirements, which assure that the final waste product meets the requirements of applicable Federal, State and Disposal Site Waste form requirements.

1.2.

Scope This Program is applicable to low level radioactive waste, which requires processing to meet Reference 2.1 stability and liquid content requirements.

2.

REFERENCES 2.1.

NRC, Title 10, Part 61, "Licensing Requirements for Land Disposal of Radioactive Waste" 2.2.

NRC, Title 10, Part 20, "Standards for Protection Against Radiation" 2.3.

NRC, Title 10, Part 71, "Packaging and Transportation of Radioactive Material" 2.4.

DOT, Title 49, "Transportation, Sub Chapter C - "Hazardous Materials Regulatiqns, Part 173, "Shippers - General Requirements for Shipments."

2.5.

NRC, Regu.latory Guide 1.143, "Design Guidance for Radioactive Waste Management Systems, Structures, and Components Installed in Light-Water-Cooled Nuclear Power Plants" 2.6.

Amendment# 72 to License DPR-45, Lacrosse Permanently Defueled Technical

  • Specifications (PDTS) 2.7.

NRC, Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants" 2.8.

LaCrosseSolutions, procedure LC-RP-PR-025, "Generation of the Annual Radioactive Effluent Release Report (ARERR)"

2.9.

NRC Branch Technical Position On "Concentration Averaging and Encapsulation",

dated January 1995 2.10.

NRC Branch Technical Position On "Waste Form", Revision 1, dated January 1991 2.11 NRC Low-Level Waste Licensing Branch Technical Position on Radioactive Waste Classification-1983 Page 3 of7

Process Control Program LC-WM-PG-001 Revision 0 2.12 NEI 07-1 OA, Generic FSAR Template Guidance for Process Control Program (PCP)

March 2009

3.

GENERAL 3.1.

Responsibilities 3.1.1 Waste Management is responsible for:

Preparing and maintaining the Process Control Program and implementing procedures.

Ensuring that waste is processed and packaged in accordance with the applicable procedures and the disposal facility waste acceptance criteria.

3.2.

Definitions 3.2.1 Disposal Facility - A state or NRC licensed off-site facility used for the disposal of radioactive waste.

3.2.2 Dewatering-means the process, which removes the loosely bound liquid from a wet radioactive waste such that the accumulation of Free Standing Liquid in a disposal container is unlikely to approach the disposal limit threshold values of the disposal site.

3.2.3 Dry Active Waste (DAW) - Radioactive waste that is typically paper, wood, plastic, trash, air filters, metal, soil, concrete, asphalt, and used plant components, whiCh without processing, contains essentially no free liquid.

3.2.4 Free Standing Liquid-means liquid that isin a disposal container but is not bound by the waste in the container.

3.2.5 Radioactive Waste Package - The packaging, together with its radioactive contents, as presented for transport.

3.2.6 Radioactive Waste Packaging - The assembly of components necessary to ensure

. compliance with the packaging requirements of 49 CFR and 10 CFR 71. It may consist of one or more containers, absorbent materials, spacing structures, thermal insulation, radiation shielding, and devices for cooling or absorbing mechanical shocks. The vehicle, the tie-down system, and auxiliary equipment may be designated as part of the packaging.

3.2.7 Radioactive Material - Byproduct material, source material, special nuclear material (SNM), and technologically enhanced naturally occurring radioactive material (TENORM).

Page 4 of7

Process Control Program LC-WM-PG-001 Revision 0 3.2.8 Radioactive Material (for shipping purposes only) - Material having a specific and total activity as defined in 49 CFR 173.436. If the material is not radioactive for the purposes of hazardous material Class 7 transport, it is not subject to the.

requirements of 49 CFR 1 73. However, the material is not considered to be cleared or authorized for unrestricted (free) release, nor is it considered to be non-radioactive under the provisions of 10 CFR 20.

3.2.9 Stabilized - The use of an approved container or process to provide an acceptable, stable waste form. Some waste forms themselves are inherently stable.

3.2.10 Temporary System - Systems intended for short-term duration and subsequent removal once they have completed their specific task or tasks. This does not include permanent systems, consumables or vehicles and casks used for pick up or delivery service. Mobile radioactive waste processing systems used to support decommissioning activities are examples of temporary systems.

3.2.11 Waste Stream - An individual, specific type or source ofradioactive waste and its associated process that exhibit similar radionuclide distributions and similar physical and chemical characteristics.

3.2.12 Wet Waste - Radioactive waste containing free standing liquids greater than the applicabl~ waste acceptance criteria.

3.3.

LACBWR Site Restoration Project Planned Activities The LACBWR Site Restoration Project does not plan to ship Class B waste, Class C waste, wet waste or mixed waste directly to a disposal facility. These waste types will be shipped to processing facilities prior to disposal. Program elements identified are consistent with the planned activities.

3.4.

Process Control.Program Administration Changes to the PCP or implementing procedures will be reviewed to assure that the requirements of applicable Federal, State and disposal site waste acceptance criteria and waste processing facility are met. PCP changes will be sent to the NRC with the Annual Radioactive Effluent Report.

Implementing procedures are developed, approved and maintained for performing activities in support of the PCP. Examples of functions that may be addressed in implementing procedures include:

Sampling, analysis, scaling of hard to detect radionuclides and waste classification Control and acceptance of vendor waste processing equipment and processes for site and offsite processing of radioactive waste Page 5 of7

Process Control Program LC-WM-PG-001 Revision 0 Verification of compliance with disposal and processor site* acceptance*

criteria.

3.5 Approval Process For QA Approved Suppliers Purchase orders for Suppliers for PCP related services will be reviewed and approved in accordance with EnergySolutions Purchasing procedures.

3.6 PCP Requirements for Vendor Processes and Services Vendors providing PCP services off site will meet the requirements of their PCP process and applicable quality assurance requirements.

3.7 Waste Types Expected The waste types planned for disposal from the LACBWR site restoration project include Class A Waste, a limited amount of water processing media, oily waste and dry active waste. Waste will be evaluated for Class Band Class C wastes prior to packaging based on the dose rate to curie content classification methodology.

3.8 PCP Solidification Process Description No solidification of waste is anticipated for the LA CB WR site restoration project. If solidification is to be used to process waste to an acceptable form, then the PCP will be revised to reflect the change.

3.9 PCP Dewatering Process Description No dewatering of water processing media for final disposal is anticipated for the LACBWR site restoration project.,

Addition of absorbent to waste packages and containers to absorb incidental quantities ofliquids and condensation is anticipated and is beyond the scope of this

  • Program.

, 3.10 Annual Radioactive Effluent Release Report Input Reference 2.8 provides direction for submission of the Annual Radioactive Effluent Release Report. Waste management will provide the following input.

Include the following information for each type of solid waste shipped offsite during the report period:

A.

Dry compressible waste, contaminated equipment etc.

B.

Irradiated components.

C.

Other (furnish description).

Page 6 of7

LC-WM-PG-001 Process Control Program Revision 0

i.

Indicate the following information for each type of waste listed above (A - C):

IL Total Volume in cubic meters.

Total Radioactivity in Curies (specify whether determined by measurement or estimate)

Principal radionuclides (specify whether determined by measurement or estimate).

Type of container (e.g., LSA, Type A).

Solidification Agent (e.g., cement, urea formaldehyde).

Dates of shipment and disposition. Identify the number of shipments, the mode of transport, and the destination.

The disposition of irradiated fuel shipments. Identify the number of shipments, the mode of transport, and the destination.

Estimates of the total error associated with certain total values.

Page 7 of7