LR-N17-0034, Salem Generating Station, Units 1 & 2, Revision 29 to Updated Final Safety Analysis Report, Section 11.6, Tables 11.6-1 (Deleted) and 11.6-2

From kanterella
(Redirected from ML17046A521)
Jump to navigation Jump to search
Salem Generating Station, Units 1 & 2, Revision 29 to Updated Final Safety Analysis Report, Section 11.6, Tables 11.6-1 (Deleted) and 11.6-2
ML17046A521
Person / Time
Site: Salem  PSEG icon.png
Issue date: 01/30/2017
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17046A230 List: ... further results
References
LR-N17-0034
Download: ML17046A521 (10)


Text

TABLE 11.6-1 This Table Deleted 1 of 1 SGS-UFSAR Revision 15 June 12, 1996 Med_;_um and Anc.lysis Performed AQUATIC ENVIRONMENT Surface Water H-3 Alpha (soluble) Alpha (insoluble} Alpha (total) Beta (soluble) Beta (insoluble} Beta (total) K-40 Sr-89 Sr:-90 Gamma K-40 ZrNb-95 cs-137 Ra-226 Solids Chlorides Edible Fish Flesh H-3 {aqueous) H-3 (organic) H-3 /organic) Sr-89 Sr-90 SGS-UFSAR TABLE 11.6-2

SUMMARY

OF RADIONUCLIDE CONCENTRATIONS IN ARTIFICIAL ISLAND PREOPERATIONAL RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLES Number of Number Average samEles Analyzed Above MDL Minimum Maximum +/- 2 259 222 <80 600+100 213+165 136 6 <1.5 33+32 136 5 <1.5 3 .3+1. 0 123 22 <1.5 27+20 136 136 3.8+/-2.5 120+/-16 42+/-52 136 14 <3.0 4.8+/-3.2 123 123 3.3+/-2.7 110+/-11 32+/-45 136 136 0.20+/-0.02 120+/-12 41+/-63 65 5 <0.37 1.5+/-0.8 77 20 <0.28 1.6+/-0.4 259 200 <6 200+/-30 48+/-64 2 <0.4 1.9+/-0.6 2 <0.5 0.86+/-0.56 9 <0.9 4. 0+/-1. 4 136 136 160+/-16 14000+/-1400 5748+/-7137 136 136 32+/-3 17000+/-1700 3345+/-5567 28 15 <80 460+/-78 165+/-206 19 17 <130 480+/-69 285+/-205 8 4 <80 390+/-80 158+/-230 9 0 <4.1 <100 12 1 <4.1 67+/-11 1 of 9 Units pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/l pCi/1 pCi/1 pCi/1 mg/1 mg/1 pCi/1 pCi/1 pCi/kg(dry) pCi/kg(wet} pCi/kg{wet) Revision 6 February 15, 1987 Medium and Number of An""lysis Performed SamEles Analyzed Edlble Fish Flesh (:ontl Gam'lla 31 K-40 cs-137 Ra-226 Edible Fish Bone Sr-89 18 Sr-90 18 Blue Crab -Edible Hard Shell (Flesh} H-3 (Aqueous) 8 H-3 (Organic) 2 H-3 (Organic) 4 H-3 (Total Tr-itium) 7 Sr-89 10 Sr-90 10 Gamma [(-40 16 ZrNb-95 Ra-226 Blue Crab -Edible Soft Shell (Total} H-3 (Aqueous) 4 H-3 (Organic) 2 H-3 (Organic) 2 H-3 (Total Tritium) 4 Sr-89 6 sr-90 8 Gamma K-40 7 ?.a-226 TABLE 11. 6-2 Number Above MDL Minimum 31 1000+/-100 5 8.7+/-6.6 1 <4 3 100+/-60 14 <24 7 <80 2 95+/-78 1 <80 5 <80 0 <6.0 7 <5.1 16 960+/-384 1 <5 3 <10 3 <80 0 <140 1 <80 3 <80 1 <7.5 5 <7.8 7 770+/-462 1 <10 2 of 9 (Contl Maximum 13000+/-1000 11+/-6 130+/-80 100+/-70 940+/-100 330+/-71 420+/-120 90+/-80 420+/-60 <51 150+/-26 12000+/-1000 120+/-12 33+/-19 320+/-110 <220 130+/-80 500+/-68 <26 39+/-6 3000+/-300 37+/-15 Average + " Sigma 2914+/-4351 335+/-614 180+/-168 259+/-455 219+/-259 40+/-103 2835+/-5048 190+/-197 105+/-71 230+/-373 21+/-24 2040+/-1359 Units pCi/kg(wet) pCi/kg(wet) pCi/kg(wet) pCi/kg(wet dry) pCi/kg(wet dry) pCi/1 pCi/1 pCi/kg{dry} pCi/1 pCi/kg(wetJ pCi/kg(wet) pCi/kg(wet dryl pCi/kg (wet) pCi/kg(wet} pCi/1 pCi/1 pCi/kg(dry) pCi/1 pCi/kg(wet) pCi/kg{wet} pCi/kg{wet) pCi/kg(wetJ Revision 6 February 15, 1987 TABLE 11.6-2 Medium and Number of Nmnber Analysis Performed SamEles Analvzed Above MDL Minimum Blue Crab -Nonedible Hard Shell (Shell) Sr-89 B 3 <57 SR-90 8 8 330+/-30 Prey Fish Sr-89 16 2 <5.8 Sr-90 16 8 <4.8 Gamma 29 K-40 29 970+/-100 ZrNb-95 2 <3 Cs-137 1 <2 Ra-226 1 <5 Benthos Sr-89 12 1 <44 Sr-90 12 5 <120 Ganuna K-40 4 2 <1 Mn-54 1 <0.03 Nb-95 2 <0.09 Ru-106 1 <0.3 Cs-137 1 <0.07 Ra-226 4 0.26+/-0.08 Th-232 4 0.52+/-0.13 Zooplankton Sr-89 8 2 <0.21 Sr-90 8 5 <0.51 3 of 9 SGS-UFSAR (Cont} Maximum 210+/-170 990+/-87 320+/-22 66+/-11 13000+/-1000 17+/-5 42+/-38 13+/-9 <36000 <30000 6. 9+/-1. 8 0.13+/-0.09 0 .11+/-0. 08 0.91+/-0.65 <0.1 0.48+/-0.16 1.2+/-0.4 4.6+/-4.4 <4.9 Average +/- 2 Si9!!.!a 614+/-511 28+/-40 4604+/-6667 3.4+/-5.0 0.11+/-0.13 0.38+/-0.18 0.80+/-0.61 1. 3+/-2. 9 Units pCi/kg(dry) pCi/kg(dry} pCi/kg{wet dry) pCi/kg(wet dry) pCi/kg(wet dry} pCi/kg{wet) pCi/kg(wet) pCi/kgCwet) pCi/kg(dry) pCi/kg(dry) pCi/g(dry} pCi/g{dry) pCi/g(dry) pCi/g(dry) pCi/g{dry) pCi/g(dry) pCi/g (dry) pCi/g (dry) pCi/g{dryl Revision 6 February 15, 1987 Medium and Number of Analysis Performed SamEles Analyzed Zooplankton (Cent) Gamma 20 Be-7 K-40 ZrNb-95 Ra-226 Sediment Sr-89 12 Sr-90 16 Gamma 41 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Sb-125 :::.:s-137 :::e-1<';4 6 Th-232 ATMOSPHERIC ENVIRONMENT Air Particulates Alpha 1045 Beta 1088 Sr-89 60 Sr-90 60 SGS-UFSAR TABLE 11. 6-2 Nwn.ber Above MDL Minimum 1 3 <3 2 <0.09 1 <0.2 0 <0.03 4 <0.03 3 <0.1 41 3.4+/-0.4 8 <0.01 1 <0.02 1 <0.01 2 0.03+/-0.02 8 0.05+/-0.04 35 <0.01 2 <0.1 41 0.28+/-0.04 41 0.21+/-0.11 788 <0.16 1585 5.0 18 <0.15 46 <0.20 4 of 9 (Cent) Maximum 3.0+/-2.8 llO+/-BO <10 <30 <1.0 0.32+/-0.05 2.3+/-0.3 21+/-2 2.6+/-0.6 0.70+/-0.30 0.31+/-0.13 0.30+/-0.11 0.27+/-0.12 0.40+/-0.04 0.48+/-0.14 1.2+/-0.1 1.3+/-0.1 7.9+/-3.1 920+/-24 4.7+/-0.5 3.0+/-0.3 Average +/- 2 Sigma 15+/-23 0.15+/-0.22 0.76+/-0.43 0.84+/-0.54 1.1+/-2. 8 74+/-280 0. 9+/-1. 6 Units pCi/gtdryl pCi/g (dry) pCi/G {dry) pCi/g(dry) pCi/g(dry) pCi/g(dryl pCi/g (dryl pCi/g (dryl pCi/g (dryl pCi/g{dryl pCi/g(dryl pCi/g(dry) pCi/g(dryl pCi/g(dryl pCi/g(dryl pCi/g(dryl pCi/g(dryl 1D-3pCi/rrr 10-3pCi/rrr 10-3pci/rrf 10-3pci/ml Revision 6 February 15, 1987 Medium and Number of Analysis Performed SamEles Analyzed Air Particulates {Cant) Gamma 127 Be-7 Mn-54 Zr-95 Nb-95 Ru-103 Ru-106 Sb-125 Cs-237 BaLa-140 Ce-141 Ce-144 Ru-226 Th-232 Air Iodine I-131 519 Precipi t atior, R-3 63 Alpha 63 Beta 63 K-40 35 Sr-89 16 Sr-90 20 Gamma 22 Be-7 K-40 Kr/Nb-95 Ru-103 Cs-137 BaLa-140 ce-144 SGS-UFSAR TABLE 11.6-2 Number Above MDL Minimum 127 12+/-7 31 <0.1 80 <0.3 74 <0.4 90 <0.1 60 <0.9 55 <0.4 122 <0.2 3 <0.4 38 <0.2 99 <1 26 <0.6 24 <0.5 20 <0. 72 49 <80 6 <0.45 57 <3.0 32 <0.01 7 <0.43 12 <0.48 16 0.75+/-0.22 3 <5 9 <0.4 2 0.48+/-0.29 1 <0.5 1 <0.4 1 <3 5 of 9 (Cont) Maximum 330+/-33 2.6+/-0.4 44+/-5 27+/-4 84+/-8 46+/-4 6.2+/-0.8 11+/-1 27+/-8 46+/-5 120+/-15 16+/-7 3 .1+/-0 .18 42+/-4 610+/-90 4. 7+/-1.8 71+/-8 0.52+/-0.05 5. 6+/-1.2 3. 8+/-1.1 79+/-74 18+/-5 9.5+/-1.0 3.4+/-0.5 1.2+/-0.4 2.2+/-0.9 6.2+/-2.2 Average +/- 2 Sigma 109+/-126 5+/-15 4+/-13 13+/-39 2.2+/-4.7 19+/-54 216+/-290 19+/-36 0.13+/-0.21 1.5+/-2.2 29+/-45 Units 10-" pCi/ni' 10-" pCi/Jn'l 10-3 pCi/Jn'l 10-3 pCi/m> 10-" pCi/m> 10-" pCi/Jn'l 10-" pCi/Jn'l 10-3 pCi/m> 10-3 pCi/m> 10-' pCi/Jn'l 10-3 pCi/Jn'l 10-' pCi/m> 10-' pCi/Jn'l 10-3 pCi/Jn'l pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 Revision 6 February 15, 1987 Medium and Number of Anal:rsis Performed Sarnt::les Analyzed TERRESTRIAL ENVIRONMENT We_l Water l-l-3 144 Alpha 144 Beta 144 K-40 134 sr-es 24 Sr-90 24 Gamma 39 Be-7 K-40 ZrNb-95 Ra-226 Potable Water (Raw and treated> H-_-i 94 Alpi"'.a 94 Beta 94 K-40 84 Sr-89 24 Sr-90 28 Gamma 32 Ra-226 Milk Sr-89 177 Sr-90 193 I-131 167 SGS-UFSAR TABLE 11.6-2 Number Above MDL Minimum 23 <40 4 <1.0 126 <2.1 134 1.1+/-0.1 1 <0.49 3 <0.36 3 32+/-7 10 <0.5 2 <0.4 1 <0.8 73 <80 16 <0.53 63 <2.6 84 0.50+/-0.10 3 <0.33 10 <0.26 1 <0.8 35 <0.55 169 <0.23 44 <0.03 6 of 9 {Cont) Maximum 380+/-77 9.6+/-2.5 38::!:6 19+/-2 <2.1 0.87+/-0.52 45+/-9 30+/-14 2.0+/-0.7 2.0+/-1.2 350+/-80 2. 7+/-1. 3 9.0+/-3.4 10+/-1 1.1+/-0.9 2 .1+/-1.2 1.4+/-1.0 14+/-2 12+/-3 65::!:6 Average +/- 2 Sigma 9+/-10 7.8+/-7.6 179+/-173 4.2+/-3.0 l. 7+/-2 .2 3.5+/-7.5 Units pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/l pCi/1 pClll pC_;_/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 pCi/1 Revision 6 February 15, 1987 TABLE 11.6-2 Medium and NUI!lber of NUI!lber Performed Sam£les Analyzed Above MDL Minimum Milk (Contl Gamma 270 K-40 270 800+/-100 I-13l 5 <0.4 :s-L37 147 <0.4 ::l.a-2::6 9 <0.9 Food ?roducts sr-89 29 3 <2.5 sr-90 45 24 <1.5 Gamma 52 K-40 52 70+/-50 Cs-137 7 <1 Fodder crops (dry) Gamma 41 Be-7 21 0.80+/-30 K-40 41 2.9+/-0.5 Co-58 3 <0.02 ZrNb-95 18 <0.02 Zr-95 3 4.3+/-0.4 Nb-135 3 3.0+/-0.3 Ru-103 4 0.09+/-0.02 RuRj-206 14 <0.01 I-131 3 <0.01 I-133 3 <0.02 cs-137 6 <0.01 BaLa-140 3 <0.02 *Additional egg plant sampled 10-13-76 reported in units of pCi/kg(dry}. Results were: Sr-89, <55 pCi/kg(dry); Sr-90, 32+/-24 pCi/kg(dry). {These data not included in ranges, or average). 7 of 9 SGS-UFSAR {Cont) Maximum 2000+/-200 63+/-14 14+/-11 <30 10+/-6* 24+/-6* 4800+/-480 59+/-33 9.3+/-0.9 80+/-8 0.07+/-0.05 9.5+/-4.8 6.3+/-0.6 4.2+/-0.4 1. 3+/-0.1 2.5+/-0.2 0.53+/-0.06 0.46+/-0.11 0.11+/-0.02 3.1+/-0.3 Average +/- 2 Sigma 1437+/-440 3.0+/-5.1 7+/-11 2141+/-1628 22+/-33 Units pCi/1 pCi/1 pCi/1 pCi/1 PCi/kg(wet) PCi/kg(wet) PCi/kg(wet) PCi/kg(wet) pCi/gldry) pCi/g(dry) pCi/g(dry) pCi/g(dry) pCl/g (dry) pCi/g (dry) pCi/g{dry) pCi/g (dry} pCi/g(dry) pCi/g (dry) pCi/g(dry} pCi/g(dry) Revision 6 February 15, 1987 Medium and Number of Analysis Performed Samples Analyzed Fodder Crops (dry) (Cent} Garruua Ce-141 4 Ce-144 5 Ra-226 1 Th-232 3 Fodder Crops (wet) Gamma 5 Be-7 4 K-40 5 ZrNb-95 1 Zr-95 4 Nb-95 4 Mo-99 4 Ru-103 4 I-131 4 I-132 4 Te-132 4 I-133 4 Ba-140 4 La-140 4 Ce-141 4 Ce-144 1 Np-239 3 Game Sr-89 11 1 Sr-90 11 11 Gamma 16 K-40 16 RuRh-106 1 cs-137 1 Ra-226 2 Th-232 2 SGS-UFSAR TABLE 11.6-2 Number Above MDL Minimum 0.28+/-0.03 5.1+/-0.5 <0.1 1. 4+/-0 .3 <0.04 0.10+/-0.04 <0.07 0.39+/-0.08 0.47+/-0.17 4.7+/-0.5 2.9+/-0.5 16+/-2 0.03+/-0.02 0.28+/-0.04 1. 9+/-0 .2 0.04+/-0.02 0.36+/-0.04 <0.01 2.2+/-0.2 0.04+/-0.02 0.59+/-0.05 <0.01 2.4+/-0.2 0.23+/-0.06 1.4+/-0.1 <0.01 1. 8+/-0.2 <0.01 0.3+/-0.05 0.50+/-0.22 2.8+/-2.0 0.13+/-0.03 3.0+/-0.3 0.06+/-0.03 1.1+/-0.1 <0.08 0.45+/-0.25 0.72+/-0.20 3.2+/-0.3 <90 <800 32+/-16 1800+/-600 1600+/-200 27000+/-800 <10 <66+/-55 <3 620+/-50 <6 1000+/-100 20+/-10 140+/-40 8 of 9 (Cent) Maximum 2.0+/-3.7 7+/-11 1.4+/-1.5 0.27+/-0.30 1.1+/-1. 9 0.21+/-0.46 1.1+/-2. 0 0.79+/-0.96 0. 7+/-1.5 0.19+/-0.31 1.8+/-2.0 1. 8+/-2. 4 0.77+/-0.96 2.0+/-2.5 249+/-540 4444+/-12124 Average +/- 2 pCi/g(dry) pCi/g{dry) pCi/g{dry) pCi/g(dry) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g(wet) pCi/g{wet) pCi/g(wet) pCi/g(wet) pCi/g{wet) pCi/kg(dry} pCi/kg(dry) pCi/kg(wet dry) pCi/kg(wet) pCi/kg(wet) pCi/kg(wet) pCi/kg(wet) Units Revision 6 February 15, 1987 Medium and Number of Analysis Performed Samples Analyzed Fodder Crops (wet) (Cent.) Thyroid Garruna 7 K-40 1 I-131 1 Soil Sr-90 21 18 Gam.rna 30 Be-7 4 K-40 30 Mn-54 2 ZrNb-95 1 zr-95 2 Nb-95 3 Sb-125 4 Cs-137 29 Ce-144 2 Ra-226 30 Th-232 30 DIRECT RADIATON Garruna Dose 3872M 3872 1256Q 1256 260SA 260 SGS-UFSAR TABLE 11 . 6-2 Number Above MDL Minimum <400 1800+/-600 <30 89+/-1 <0.03 1.1+/-0.1 0.18:+/-0 .13 21+/-10 3.4+/-0.4 24+/-2 <0.01 0.01+/-0.01 <0.02 0.02+/-0.02 0.03+/-0.02 0.06+/-0.04 0.07+/-0.02 0.09+/-0.02 0.05+/-0.04 0.27+/-0.07 <0.1 2.8+/-0.3 <0.09 0.51+/-0.12 0.27+/-0.05 1. 5+/-0 .2 0.14+/-0.06 1.4+/-0.1 2.07+/-0.14 7.28+/-0.36 1. 07+/-0. 24 5.60+/-0.54 2.83+/-0.10 5.21+/-0.22 9 of 9 (Cont} Maximum 0.26+/-0.50 10+/-8 o. 8+/-1.5 0.87+/-0.65 0.74+/-0.58 4.26+/-1.53 4.62+/-1.18 4. 30+/-1.15 Average +2 Sigma PCi/kg(wet} PCi/kg(wet) pCi/g{dry) pCi/g{dry) pCi/g{dry) pCi/g(dry) pCi/g(dry) pCi/g(dry) pCi/g(dry) pCi/g{dry) pCi/g(dry) pCi/g(dry) pCi/g{dry) pCi/g{dry) rnrad/std.mon. mrad/std.mon. mrad/std.rnon. Units Revision 6 February 15, 1987