MONTHYEARML24012A0492024-01-11011 January 2024 Request for Additional Information Regarding Final Response to Generic Letter 2004-02 ML23311A1682023-11-0707 November 2023 NRR E-mail Capture - Constellation - Fleet Request - Acceptance of Proposed Alternative for Examinations of Examination Category C-B Steam Generator Nozzle-to-Shell Welds and Nozzle Inside Radius Sections (L-2023-LLR-0053 and L-2023-LLR-005 ML23311A1692023-11-0707 November 2023 NRR E-mail Capture - Constellation - Fleet Request - Acceptance of Proposed Alternative for Examinations of Exam Categories B-B, B-D, and C-A SG Pressure Retaining Welds and Full Penetration Welded Nozzles (L-2023-LLR-0055 and L-2023-LLR-00 ML23304A0152023-10-30030 October 2023 NRR E-mail Capture - Final RCI - Constellation Energy Generation, LLC - Calvert Cliffs 1 & 2 - Exemption from Security Rule (L-2023-LLE-0033) ML23181A0732023-06-30030 June 2023 NRR E-mail Capture - Acceptance Review for Calvert Cliffs TSTF-59A ML23160A0222023-06-0606 June 2023 NRR E-mail Capture - Calvert Cliffs - Long Term Coupon Surveillance Program RAI ML23156A0102023-06-0404 June 2023 NRR E-mail Capture - Calvert Cliffs - RAI License Amendment Request for Emergency Desiel Generator ML23080A1002023-03-21021 March 2023 NRR E-mail Capture - Acceptance Review for Calvert Cliffs Repair Replacement of Saltwater System Buried Piping ML23080A0672023-03-21021 March 2023 NRR E-mail Capture - Acceptance Review for Calvert Cliffs Unit 1 - LAR to Modify the Long-Term Coupon Surveillance Program ML23026A1332023-01-26026 January 2023 NRR E-mail Capture - Acceptance Review for Calvert Cliffs Deletion of License Condition for Decommissioning Trust LAR ML22354A2622022-12-20020 December 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Request to Use Certain Provisions of the 2019 Edition of the ASME BPV Code, Section XI ML22342B1462022-11-21021 November 2022 NRR E-mail Capture - Acceptance Review for TSTF 295A ML22325A0052022-11-18018 November 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-273-A, Revision 2 ML22255A0132022-09-0909 September 2022 NRR E-mail Capture - NRC Acceptance Review of Braidwood, Byron, Calvert Cliffs, Ginna - License Amendment Request to Adopt TSTF-577 ML22200A0782022-07-19019 July 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request to Use Honeywell Mururoa V4F1 R Supplied Air Suits ML22271A0772022-05-0606 May 2022 NRR E-mail Capture - Final RAIs 9.1.2021 Constellation Relief Request ML22129A0132022-05-0606 May 2022 NRR E-mail Capture - Draft RAIs for Requests for Alternatives I4R-17, I4R-23, ISI-05-018, I6R-10 ML22091A2392022-04-0101 April 2022 NRR E-mail Capture - Calvert Cliffs - Formal RAI for Proposed Alternative for Examinations of Certain Pressurizer Welds ML22091A0852022-04-0101 April 2022 NRR E-mail Capture - Braidwood and Byron - Final RAI Regarding Proposed Alternative for Various Pressurizer Welds (EPID L-2021-LLR-0035 and 0036) ML22091A2402022-03-23023 March 2022 NRR E-mail Capture - (External_Sender) Salem Generating STATION-INCIDENTAL Take of Atlantic Sturgeon Collected on 03/22/2022 ML22075A1912022-03-16016 March 2022 NRR E-mail Capture - Acceptance for Review of Proposed Alternative Repair Method for Buried Class 3 Saltwater System Piping ML22088A1562022-03-0202 March 2022 NRR E-mail Capture - Byron, Braidwood, Calvert Cliffs, and Ginna - Non-acceptance of Application to Revise Technical Specifications 5.6.5.b, the Core Operating Limits Report (COLR) ML22059B0602022-02-28028 February 2022 Change to Review Schedule Regarding Proposed Alternative for Various Pressurizer Welds ML22060A0172022-02-23023 February 2022 NRR E-mail Capture - Calvert Cliffs Nuclear Power Plant, Units 1 and 2 - Withdraw of Draft RAI Regarding Proposed Alternative for Various Pressurizer Welds ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML21281A1402022-01-14014 January 2022 Acceptance for Review of Proposed Alternative ISI-05-018 for Examinations of Steam Generator Pressure Retaining Welds and Full Penetration Welded Nozzles ML21301A0672021-10-28028 October 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-541 ML21295A5712021-10-22022 October 2021 NRR E-mail Capture - Acceptance for Review of Proposed Alternative ISI-05-019 for Pressure Testing of Certain Portions of ASME Section XI Class 2 Auxiliary Feedwater Piping ML21287A0322021-10-13013 October 2021 Request for Additional Information Re Proposed Alternative for Pressurizer Circumferential and Longitudinal Shell-to-Head Welds and Nozzle-to-Vessel Welds ML21286A5902021-10-0505 October 2021 Acceptance for Review of Proposed Alternative ISI-05-017 for Examinations of Examination Category C-B Steam Generator ML21287A0932021-10-0505 October 2021 Request for Additional Information: Calvert Cliffs 1 & 2 LAR to Revise Spent Fuel Pool Cooling - Shutdown Cooling Systems Licensing Basis (EPID L-2021-LLA-0112) (Email) ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21214A0202021-08-0909 August 2021 License Amendment Request to Change Spent Fuel Pool Cooling Design Basis ML21215A3502021-08-0303 August 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-554 ML21201A0482021-07-19019 July 2021 Acceptance of Requested Licensing Action to Change Spent Fuel Pool Cooling Design Basis ML21180A1562021-06-28028 June 2021 Request for Additional Information Regarding License Amendment Request Concerning Containment Sump ML21152A1232021-06-0101 June 2021 Acceptance for Review of Proposed Alternative ISI-05-016 Involving Examination of Pressurizer Circumferential and Longitudinal Shell-to-Head Welds and Nozzle-to-Vessel Welds (EPID L-2021-LLR-0037) (Email) ML21154A0132021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0112021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0142021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21117A0442021-04-26026 April 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21084A2532021-03-24024 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Transfer Application ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) ML21033A8552021-02-0202 February 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request to Expand the Use ASME Codes Cases N-878 and N-880 ML21029A3302021-01-29029 January 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Fleet Alternative Request to Use ASME Code Case N-885 ML21022A0092021-01-21021 January 2021 Request-Calvert Cliffs-Exelon Generation Co., LLC ML20352A3802020-12-17017 December 2020 Acceptance of Requested Licensing Action to Add Containment Sump Technical Specifications ML20350B5582020-12-14014 December 2020 NRR E-mail Capture - Exelon Generation Company, LLC -Alternative Request for Documentation of Replacement of Pressure Retaining Bolting 2024-01-11
[Table view] Category:Meeting Minutes
MONTHYEARML16225A7742016-08-12012 August 2016 Memo to File: Summary of July 18, 2016, Meeting with Exelon Nuclear Generation to Discuss Calvert Cliffs Units 1 and 2 - Generic Letter 2004-02 Resolution Update 2016-08-12
[Table view] |
Text
From: Guzman, Richard Sent: Friday, August 12, 2016 10:59 PM To: Guzman, Richard
Subject:
Memo to File:
SUMMARY
OF July 18, 2016, Meeting with Exelon Nuclear Generation to Discuss Calvert Cliffs Units 1 and 2 - Generic Letter 2004-02 Resolution Update On July 18, 2016, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Exelon Generation Company, LLC (Exelon, the licensee) at NRC Headquarters, Three White Flint North, 11601 Landsdown Street, Rockville, Maryland. The purpose of the meeting was to discuss the licensees June 8, 2016, supplemental response to Generic Letter 2004-02 regarding revised zone of influence and debris size distribution information, and to provide an update to the staff on its resolution path activities and risk-informed closure plan for the Calvert Cliffs Nuclear Power Plant, Units 1 and
- 2. The meeting notice and agenda, dated July 5, 2016, is available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML16187A162. The licensees slides are available in ADAMS at Accession No. ML16198A001. The licensee presented a summary of the following:
- Discussion of Calvert Cliffs simplified risk-informed approach
- Strainer performance criteria and preliminary results
- Discussion of revised zone of influence (ZOI) and debris size distributions
- Current schedule for submitting closure submittal with risk-informed GSI-191 analysis and results, including plan for exemption from 10 CFR 50.46
- Proposed plan and schedule for next meeting The licensee provided an overview of its risk-informed approach for resolving GSI-191 which included a description of the strainer performance criteria and preliminary results which showed no threat to strainer performance. The licensee then discussed its plan for submitting an exemption request from 10 CFR 50.46(a)(1) requirements which will follow the precedent exemption submitted by South Texas Project. The licensee stated that it is not licensed to 10 CFR 50 Appendix A General Design Criteria (GDC), and therefore, do not intend to submit an additional exemption for the Appendix A GDCs. The licensee also gave a summary of its June 8, 2016, supplemental response to GL 2004-02 (ADAMS Accession No. ML16165A490). In particular, the licensee indicated that it had discovered additional information on certain materials to enable them to revise the ZOI and debris size distribution information for these materials. Specifically, the supplemental response indicated that the revised ZOI and debris size distributions are addressed for (1) NUKON and thermal wrap blanket insulation, (2) mineral wool insulation in stainless steel cassettes, (3) generic fiberglass Insulation, and (4) lead wool shielding blankets. The licensee requested feedback from the staff on the information presented in Attachment 1 of their June 8, 2016 response. Finally, the licensee provided a general schedule and projection for submitting its final submittal for GL 2004-02. They stated that since the schedule for publication of the safety evaluations supporting the South Texas Project (STP) Risk Informed GSI-191 pilot submittal and WCAP-17788 has been extended beyond original target date (2nd quarter 2016), the licensee plans to submit it closure submittal for GL 2004-02 no later than three months after the NRC staff issues the safety evaluation for the STP risk-informed GSI-191 and the WCAP (whichever is later).
Next steps: The next public meeting will be targeted for September 2016; the licensee plans to present follow-up information regarding its treatment of longitudinal welds and its proposed centroid methodology with preliminary results.
No members of the public were in attendance, and no feedback forms were received. No decisions were made regarding the acceptability of Exelons proposed submittals.
LICENSEE: Exelon Generation Company, LLC FACILITY: Calvert Cliffs Nuclear Power Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF JULY 18, 2016, MEETING WITH EXELON GENERATION CO., LLC TO DISCUSS CALVERT CLIFFS UNITS 1 AND 2 - GENERIC LETTER 2004-02 RESOLUTION UPDATE LIST OF ATTENDEES:
U.S. NUCLEAR REGULATORY COMMISSION CJ Fong Paul Klein Steve Smith Marioly Diaz Colon Andrea Russell Ashley Smith Candace Pfefferkorn Richard Guzman EXELON GENERATION COMPANY, LLC Doug Lauver Andre Drake Jim Landale Ken Greene ENERCON Craig Sellers Tim Sande*
MPR ASSOCIATES, INC.
Eric Federline OTHER Ron Holloway (PM, Wolf Creek)*
- Participated via conference line