Notification of Inspection (NRC Inspection Report 05000285/2016003) and Request for Information
ML16203A196
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 07/21/2016
From: Vincent Gaddy
Operations Branch IV
To: Marik S
Omaha Public Power District
References
Download: ML16203A196 (9)


See also: IR 05000285/2016003

Text

July 21, 2016

Mr. Shane M. Marik, Site Vice President

and Chief Nuclear Officer

Omaha Public Power District

Fort Calhoun Station

Mail Stop FC-2-4

9610 Power Lane

Blair, NE 68008

SUBJECT: FORT CALHOUN STATION - NOTIFICATION OF INSPECTION

(NRC INSPECTION REPORT 05000285/2016003) AND REQUEST FOR

INFORMATION

Dear Mr. Marik:

From August 29 - September 1, 2016, inspectors from the Nuclear Regulatory

Commissions (NRC) Region IV office will perform the baseline biennial requalification

inspection at Fort Calhoun Station, using NRC Inspection Procedure 71111.11B, Licensed

Operator Requalification Program. Experience has shown that this inspection is a resource

intensive inspection both for the NRC inspectors and your staff. In order to minimize the impact

to your on-site resources and to ensure a productive inspection, we have enclosed a request for

documents needed for this inspection. These documents have been divided into three groups.

The first group (Section A of the enclosure) identifies information to be provided prior to the

inspection to ensure that the inspectors are adequately prepared. The second group (Section B

of the enclosure) identifies the information the inspectors will need upon arrival at the site. The

third group (Section C of this enclosure) identifies the items which are necessary to close out

the inspection and are usually sent a few weeks after the team has left the site. It is important

that all of these documents are up to date and complete in order to minimize the number of

additional documents requested during the preparation and/or the on-site portions of the

inspection.

We have discussed the schedule for these inspection activities with your staff and understand

that our regulatory contact for this inspection will be Mr. Don Bonwell, Requalification

Supervisor, of your training organization. Our inspection dates are subject to change based on

your updated schedule of examination activities. If there are any questions about this inspection

or the material requested, please contact the lead inspector John Kirkland at (817) 200-1771

(John.Kirkland@nrc.gov) or Chris Cowdrey at (817) 200-1545 (Christian.Cowdrey@nrc.gov).

This letter does not contain new or amended information collection requirements subject to

the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information

collection requirements were approved by the Office of Management and Budget, control

number 3150-0018. The NRC may not conduct or sponsor, and a person is not required to

respond to, a request for information or an information collection requirement unless the

UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION IV

1600 E. LAMAR BLVD.

ARLINGTON, TX 76011-4511

S. Marik

- 2 -

requesting document displays a currently valid Office of Management and Budget control

number.

In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice and Procedure," a copy of

this letter and its enclosure will be available electronically for public inspection in the NRC Public

Document Room or from the Publicly Available Records (PARS) component of NRCs document

system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-

rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Vincent G. Gaddy, Chief

Operations Branch

Division of Reactor Safety

Docket No. 50-285

License No. DPR-40

Enclosure:

Inservice Inspection Document Request

cc: Electronic Distribution

ML16203A196

SUNSI Review

By: VGaddy

ADAMS

Yes No

Publicly Available

Non-Publicly Available

Non-Sensitive

Sensitive

Keyword:

NRC-002

OFFICE

SOE:OB

C:OB

NAME

JKirkland

VGaddy

SIGNATURE

/RA/

/RA/

DATE

7/21/16

7/21/16

Letter to Shane M. Marik from Vincent G. Gaddy, dated July 21, 2016

SUBJECT: FORT CALHOUN STATION - NOTIFICATION OF INSPECTION

(NRC INSPECTION REPORT 05000285/2016003) AND REQUEST FOR

INFORMATION

Electronic distribution by RIV:

Regional Administrator (Kriss.Kennedy@nrc.gov)

Deputy Regional Administrator (Scott.Morris@nrc.gov)

DRP Director (Troy.Pruett@nrc.gov)

DRP Deputy Director (Ryan.Lantz@nrc.gov)

DRS Director (Anton.Vegel@nrc.gov)

DRS Deputy Director (Jeff.Clark@nrc.gov)

Senior Resident Inspector (Max.Schneider@nrc.gov)

Acting Resident Inspector (Shawn.Money@nrc.gov)

Acting Resident Inspector (Thomas.Sullivan@nrc.gov)

Site Administrative Assistant (Yvonne.Dubay@nrc.gov)

Branch Chief, DRP/D (Geoffrey.Miller@nrc.gov)

Senior Project Engineer, DRP (Vacant)

Project Engineer, DRP/D (Brian.Parks@nrc.gov)

Project Engineer, DRP/D (Jan.Tice@nrc.gov)

RIV Public Affairs Officer (Victor.Dricks@nrc.gov)

Project Manager (Fred.Lyon@nrc.gov)

Team Leader, DRS/TSS (Thomas.Hipschman@nrc.gov)

RIV RITS Coordinator (Marisa.Herrera@nrc.gov)

RIV Regional Counsel (Karla.Fuller@nrc.gov)

Congressional Affairs Officer (Jenny.Weil@nrc.gov)

RIV Congressional Affairs Officer (Angel.Moreno@nrc.gov)

Technical Support Assistant (Loretta.Williams@nrc.gov)

RIV/ETA: OEDO (Jeremy.Bowen@nrc.gov)

RIV RSLO (Bill.Maier@nrc.gov)

ACES (R4Enforcement.Resource@nrc.gov)

Enclosure

BIENNIAL REQUALIFICATION INSPECTION DOCUMENT REQUEST

From:

John Kirkland

Senior Operations Engineer, NRC RIV

817-200-1771

To:

Don Bonwell

Requalification Supervisor, Fort Calhoun Station

402-533-6038

Subject: Information Request to Support August 29 - September 1, 2016, Licensed Operator

Requalification Program Inspection (IP 71111.11B)

A. The following information is requested in order to support inspection preparation

activities. These items are listed by section as they appear in the inspection module

(i.e., 2.02, 2.04, etc.). Requested materials should be sent either electronically or

hardcopy in order to arrive at the Region IV office no later than August 15, 2016.

Electronically to: John.Kirkland@nrc.gov

cc: Christian.Cowdrey@nrc.gov

Hardcopy or electronic media to:

U.S. Nuclear Regulatory Commission, Region IV

1600 E. Lamar Blvd

Arlington, TX 76011

ATTN: John Kirkland

General Requests:

List of licensed operators (SRO and RO) by crew (operating and staff)

Training and Operations Department organization charts (with qualified LOR

evaluators identified)

Procedures that identify process for revising and maintaining LO continuing training

program up to date

List of outstanding LOR program changes

List of plant events and industry operating experience incorporated into LOR

program since last BRQ

Audits and/or self-assessment reports addressing the licensed operator

requalification training program

Last two years of simulator review committee (or equivalent) meeting minutes

Last two years of CRC (or equivalent) meeting minutes

02.03: Biennial Requalification Written Examination Quality

The current and approved biennial written examination schedule

The current requalification cycle written examination results for both SRO and RO

that have already been administered up to the week prior to the inspection team

arrival on-site.

- 2 -

All written examinations that have been approved for administration up to and

including the week before the inspection team is on-site. This will need to have

adequate password protection if e-mailed or double envelope protection if mailed via

regular mail per NUREG-1021.

The current requalification cycle examination methodology (sample plan)

02.04: Annual Requalification Operating Test Quality

The schedule for the operating tests (JPMs and scenarios) to be given the week of

August 29, 2016 (week team is on-site)

The operating tests (JPMs and scenarios) (password protected and provide

separately via telephone at later date) to be given the week of August 29, 2016

(week team is on-site)

Current requalification cycle operating tests (SRO and RO) and results up to the

week prior to the inspection team arrival on-site.

All of the previous years NRC required annual operating tests.

Current requalification cycle operating test methodology (sample plan)

All portions of the UFSAR that identify operator response times for time critical

operator actions

02.05: Licensee Admin of Requalification Examinations

All procedures used to administer the annual operating test

All procedures used to assess operator performance

All procedures that describe conduct of simulator training

All Procedures used to test, operate, and maintain the simulator

02.06: Requalification Examination Security

Submit any tracking tools that you use as a means to prevent excessive overlap on

the written examinations and also meet the intent of sampling all required topics on a

periodic basis.

Submit any tracking tools that you use as a means to prevent excessive overlap on

the operating tests and also meet the intent of sampling all required malfunctions

(including major events, instrument/component malfunctions, TS calls, etc.) on a

periodic basis.

All Procedures that describe examination security, including procedures used to

develop the examinations that include guidelines on overlap between examinations

in current examination cycle tests and prior year examinations

List of all Condition Reports since the last biennial requalification inspection related

to examination security and overlap

02.07: Licensee Remedial Training Program

List of remedial training conducted or planned since last requalification examinations

(includes training provided to operators to enable passing requalification

examinations and training provided to correct generic or individual weaknesses

observed during previous requalification examination cycle)

Remediation plans (lesson plans, reference materials, and attendance

documentation)

- 3 -

02.08: Conformance with Operator License Conditions

All Procedures and Program documentation for maintaining active operator licenses,

tracking training attendance, and ensuring medical fitness of licensed operators

All Procedures and associated documentation that supports reactivation of any

SRO/RO license (operating or staff crew) since the last biennial inspection

02.09: Simulator Performance

For the following cases, send the most recent transient test packages, which may be

electronic or in paper single test packages and shall be complete with test

procedures for each test, the acceptance criteria, and results. For each transient test,

the reference chart should be included or an equivalent subject matter expert review

versus the simulator results with a write-up for any differences beyond the ANSI 3.5

standard requirements:

o Transient test 1, Manual Rx trip

o Transient test 6, Main turbine trip (no reactor trip)

o Transient test 10, Stuck open PORV

o Steady State tests for 100% power test

All Simulator Management and Configuration Procedures if not already provided for

section 02.05 above.

Simulator Discrepancy Report summary list for all open DRs. For closed DRs,

summary list for those items closed between July 1, 2014, and June 30, 2016.

Malfunction Tests for Main Steam and Main Feed Line breaks. If these are included

in an SBT package then the review of that package would be acceptable.

Two examples of primary parameters tested in order to verify core physics

parameters (such as MTC, IRW). The applicable reference graphs from the Plant

physics data book (electronic or other means as available) should also be included

as well as the test procedures used and the acceptance criteria with results for the

selected samples.

All simulator modification packages that are on hold, delayed, or just not completed

in the last two years.

A list of simulator modification packages completed in the last two year window.

02.10: Problem Identification and Resolution

A summary report of all condition reports related to operator actions/errors in the

control room

Any revised requalification training that was based on licensed operator performance

issues

- 4 -

B. The following information is requested in order to support the on-site inspection

activities. Requested materials should be available to the inspection team, either

electronically or hardcopy, upon site arrival on August 29, 2016.

02.02: Examination Results / 02.03 and 02.04: Written Examination and Op Test Quality

All Operating tests (JPMs and scenarios) to be given in all subsequent weeks after

on-site week

All results up to the day the team leaves the site.

02.08: Conformance with Operator License Conditions

Access to licensed operators records (operating and staff crews)

Access to licensed operators training attendance records

Access to licensed operators medical records

02.09: Simulator Performance

Simulator discrepancies (DRs) from July 1, 2014, to June 30, 2016. This should

include all open DRs and DRs that have been closed, including the

documentation/justification for closure.

Acceptance test documentation, including hardware and software model revisions at

the time of acceptance (as available).

Documentation that validates current models, including the thermal-hydraulics and

neutronics models, to the actual plant.

All current model deficiencies, including FSAR vs Design differences in the simulator

(any documentation on this)

Summary list of modifications from July 1, 2014, to June 30, 2016.

Plant Modifications (both hardware and software) completed on the Simulator by due

date from July 1, 2014, to June 30, 2016.

Simulator Differences Lesson plan used in training (current to August 29, 2016).

The complete book of all Simulator annual performance test packages (usually in a

single book, but may be electronic or in single test packages), complete with all

transient tests, steady state tests, and malfunction tests. This should also include the

test procedures for each test, the acceptance criteria, and results. For each transient

test, the reference chart should be included or an equivalent subject matter expert

review versus the simulator results with a write-up for any differences beyond the

ANSI standard requirements.

All test packages used to verify core physics parameters (such as MTC, IRW). The

applicable reference graphs from the Plant physics data book (electronic or other

means as available) should also be included as well as the test procedures used and

the acceptance criteria with results.

All Simulator test, configuration management, and related documents available in the

room for inspectors to review. This includes training needs analysis packages,

simulator review committee meeting minutes, etc.

Current copy of ANSI 3.5 standard you are committed to for Simulator testing.

02.10: Problem Identification and Resolution

All condition reports related to operator actions/errors in the control room

- 5 -

C. Fort Calhoun Station is required to send the final results summary and any remaining

examinations and operating tests that have not been reviewed to the regional office

lead inspector for this inspection for final review and comparison against the

Significance Determination Tools in order to communicate the exit results for the

inspection.