UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of:

License Amendment Request of Entergy Nuclear Operations, Inc., dated December 9, 2014, for Indian Point Nuclear Generating Unit No.2 to Postpone Testing of Containment Integrity Docket No. 50-247-LA License No. DPR-26 May 18, 2015 STATE OF NEW YORK PETITION TO INTERVENE AND REQUEST FOR HEARING Office of the Attorney General for the State of New York The Capitol State Street Albany, New York 12224

Table of Contents INTRODUCTION......................................................................................................................... 1 STANDING................................................................................................................................... 2 CONTENTION NYS-1................................................................................................................. 5 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specification Should Be Denied Because It Involves a Significant Safety and Environmental Hazard, Fails to Demonstrate That It Complies with 10 C.F.R. §§ 50.40 and 50.92 or 10 C.F.R 50, Appendix J, and Fails to Demonstrate That It Will Provide Reasonable Assurance of Adequate Protection for the Public Health and Safety as Required by Section 182(a) of the Atomic Energy Act (42 U.S.C. § 2232[a]) if the Proposed Amendment to the Operating License Is Approved................................................................................................................... 5 BASES........................................................................................................................................ 5 SUPPORTING EVIDENCE.................................................................................................. 11 CONTENTION NYS-2............................................................................................................... 20 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specifications Should Be Denied Because Entergy Has Not Submitted an Environmental Report as Required By 10 C.F.R §§ 51.53 and It Has Not Undergone the Required NRC Staff Environmental Review Pursuant to 10 C.F.R § 51.101 and, Despite Entergys Claim to the Contrary, the Proposed Amendment Is Not Categorically Exempt from That Review Under 10 C.F.R. § 51.22(c)(9)............................................................................................................. 20 BASES...................................................................................................................................... 20 SUPPORTING EVIDENCE.................................................................................................. 22 CONCLUSION........................................................................................................................... 23 ii

INTRODUCTION Pursuant to 10 C.F.R. § 2.309, the State of New York (the State) seeks leave to intervene and requests a hearing with respect to an operating license amendment request (or LAR) submitted by Entergy Nuclear Operations, Inc. (Entergy) on December 9, 2014 and published in the Federal Register on March 17, 2015. See 80 Fed. Reg. 13,902 (March 17, 2015). Entergy seeks to postpone an important safety obligation that tests the integrity of the Indian Point Unit 2 containment system from early 2016 to 2021 and thereafter to perform the containment vessel integrity test once in every 15 years. Entergys LAR would increase the risk that the citizens and environment of the State will be exposed to the release of radioactive materials. In evaluating this risk, Entergy ignored important plant-specific circumstances and events that have weakened and damaged key containment components, as well as recent updates indicating elevated seismic hazards at the Indian Point site. Moreover, Entergy failed entirely to conduct any environmental review of its LAR. Because these shortcomings would prevent the NRC from making the findings necessary to grant the LAR, the State should be permitted to intervene and request a hearing with respect to the LAR.

On December 9, 2014, Entergy submitted a request seeking NRC authorization to amend Operating License DPR-26 for the Indian Point Nuclear Generating Unit No. 2 (IP2), Docket No.

50-247, to obtain a permanent extension of the frequency with which it must conduct a containment integrated leak rate test (or ILRT) from 10 years to 15 years.1 Letter from Lawrence Coyle, Site Vice President, Entergy Nuclear Northeast, to U.S. Nuclear Regulatory Commission, NL-14-128 (Dec. 9, 2014) (ML14353A015). The ILRT is an important test of containment integrity that protects the environment and members of the public from exposure to 1 Entergy had obtained a one-time extension of the ILRT frequency from 10 to 15 years in 2002. See Letter from Patrick D. Milano, Office of Nuclear Reactor Regulation, to Michael R. Kansler, Entergy (Aug. 5, 2002)

(ML021860178).

1

uncontrolled releases of radiation from the reactor. Despite its importance, since 1995, Entergy and its predecessor licensee have steadily reduced the frequency with which this leak test has been conducted, from three inspections per ten years, to one inspection per ten years, to a one-time extension to once every 15 years, and now - if Entergys LAR is granted - to once per fifteen years on a permanent basis.2 See Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-1. If the LAR is granted, the IP2 containment will next be inspected in 2021 - rather than 2016 - and, after that, will likely not be inspected again for the remaining life of the plant.

The IP2 containment liner, in particular, has been subjected to a variety of unusual degradation events over more than four decades, including buckling in 1968, deformations caused by a jet of steam and hot water in 1973, and corrosion due to a flooding event in 1980. Entergys license amendment application fails to mention, let alone consider, these plant-specific events, presenting instead a generic analysis.

STANDING The State of New York and its citizens have a direct interest in ensuring the safe operation of IP2 in Buchanan, New York, and meet all the requirements for intervenor standing under 10 C.F.R. § 2.309(d)(1).3 As required by 10 C.F.R. § 2.309(d)(1)(ii), the State has a clear right under the Atomic Energy Act (AEA) to be made a party to this proceeding. The State seeks leave to assert that the 2 The State of New York has previously expressed its concerns with extending the period between ILRTs for IP3.

See New York State Comments on Indian Point 3 Proposed License Amendment Regarding Extending the Containment Type A Leak Rate Testing Frequency to 15 Years (February 2015) (ML15055A512). Nonetheless, the NRC approved Entergys prior request to increase the period between ILRTs from once per 10 years to once per 15 years. See Letter from Douglas Pickett, Office of Nuclear Reactor Regulation, to Vice President of Operations, Entergy (March 13, 2015) (ML15028A308).

3 Section 2.309(d)(1)(i) requires a proposed intervenor set forth its name, address and telephone number[.] To the extent that this requirement applies to a State intervenor, the contact information for the States representatives can be found at the end of this Petition.

2

LAR (1) does not provide a reasonable assurance of adequate protection of public health under the Atomic Energy Act § 182(a), 42 U.S.C. § 2232(a), (2) does not comply with NRC regulations applicable to license amendment requests including 10 C.F.R. §§ 50.40 and 50.92 and 10 C.F.R 50, Appendix J, (3) involves a significant safety and environmental hazard, and (4) does not qualify for a categorical exemption to the preparation of an environmental review as required by the National Environmental Protection Act (NEPA) and implemented by NRC regulations.

Additionally, as required by 10 C.F.R. §§ 2.309 (d)(1)(iii), the State has extensive property, financial or other interest[s] that are implicated by the license amendment request.

IP2 is located just twenty-four miles north of New York City, in one of the most densely populated parts of the State or, indeed, the country. The IP2 reactor is also 6 miles west of the New Croton Reservoir in Westchester County, which is part of the New York City reservoir system and provides drinking water to New York City residents and is close to other reservoirs in the New York metropolitan area. The 50-mile area around IP2 contains some of the densest real estate development in the country, numerous landmarks, iconic and irreplaceable sites, and vital components of the State and Nations critical infrastructure. A list of historic, unique or otherwise significant sites within 50 miles of the IP2 site is attached as Attachment 1. A map of reservoirs in the vicinity of the IP2 site is attached as Attachment 2. In addition, the facility is located on the States Hudson River - an important waterway for commercial, environmental and recreational reasons - and relies on river water for steam generation and cooling.

Finally, as required by 10 C.F.R. § 2.309(d)(1)(iv), the States interests will be directly affected if the license amendment request is granted. Entergys LAR seeks to reduce the frequency of an important test of containment integrity. If a breach of containment integrity goes 3

undetected due to the reduced inspection frequency proposed by Entergy, the States citizens and environment could be exposed to an uncontrolled release of radiation. Millions of the States citizens live within 50 miles of IP2, and would be at risk of exposure to harmful radiation if such a release were to occur. Additionally, billions of dollars in property, including the countrys financial center, are located within 50 miles of IP2, and would be adversely affected by exposure to radiation. NRC Commissioners have recognized that given its location, a severe release of radioactive materials at Indian Point could have more serious consequences than that same release at virtually any other NRC-licensed site. Consolidated Edison Co. of N.Y. (Indian Point Unit 2) and Power Auth. of the State of New York (Indian Point Unit 3), CLI-85-6, 21 N.R.C. 1043, 1049-50 (1985).

Entergys request to delay and defer the containment integrity test has failed to consider a number of plant-specific events that render the IP2 containment ill-suited for a relaxation of inspection frequency. Moreover, Entergy has failed to conduct any environmental analysis of the license amendment request, and - contrary to Entergys claim - it is not categorically excluded from this requirement. Accordingly, the risk posed by an undetected loss of containment integrity to the States environment and natural resources has not been properly evaluated. The States interest in ensuring that those risks - and alternatives thereto -

are properly identified, assessed, and mitigated is manifest.

NRC has previously recognized the States interest and standing to participate in proceedings concerning the Indian Point nuclear facilities. See Entergy Nuclear Operations, Inc.

(Indian Point, Units 2 and 3), LBP-08-13 at 5, 68 N.R.C. 43 (July 31, 2008).

4

CONTENTION NYS-1 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specification Should Be Denied Because It Involves a Significant Safety and Environmental Hazard, Fails to Demonstrate That It Complies with 10 C.F.R. §§ 50.40 and 50.92 or 10 C.F.R 50, Appendix J, and Fails to Demonstrate That It Will Provide Reasonable Assurance of Adequate Protection for the Public Health and Safety as Required by Section 182(a) of the Atomic Energy Act (42 U.S.C. § 2232[a]) if the Proposed Amendment to the Operating License Is Approved.

BASES

1. In 1956, the federal Atomic Energy Commission (AEC)4 approved the Indian Point site for nuclear power reactorsbefore the government had promulgated regulations for the siting of such facilities. See 21 Fed. Reg. 3,085 (May 9, 1956). In 1966, AEC issued a construction permit for Indian Point Unit 2. See 31 Fed. Reg. 13,616-17 (Oct. 21, 1966). The Consolidated Edison Company of New York (Con Edison) undertook construction activities including the construction and fabrication of the containment liner and related systems, structures, and components. AEC subsequently issued an operating license (DPR-26) for the facility in 1973.

See e.g. 38 Fed. Reg. 27,636 (Oct. 5, 1973). The operating license contains, among other things, binding and enforceable technical specifications.

2. Entergy seeks to amend a technical specification pursuant to 10 C.F.R 50, Appendix J, Option B in order to reduce the frequency of the only inspection that tests the overall integrity of the IP2 containment liner. According to IP2s current licensing basis, the next ILRT should be conducted in 2016, followed by another inspection in 2026. Entergy proposes, instead, to conduct an ILRT once in 2021 and not again during the remaining operating life of the plant (2033). During its construction and 42 years of operation, the IP2 containment liner has been 4 The U.S. Atomic Energy Commission was the predecessor to the U.S. Nuclear Regulatory Commission.

5

subjected to a series of damaging incidents, making it ill-suited for the relaxed monitoring proposed by Entergy. Entergy claims that Option B of Appendix J dictates that the frequency of Type A leakage tests should be based on plant-specific performance data and on consideration of the operating history of the component and the resulting risk from its failure. to NL-14-182, at 2 (citing 10 C.F.R. 50 Appendix J, NEI 94-01 Revision 2A, and Regulatory Guide 1.163). However, Entergy has failed to consider the plant-specific history of the IP2 containment liner.

3. Reactor containment and associated systems shall establish a leak-tight barrier against the controlled release of radioactivity to the environment. See, e.g., 10 C.F.R. Part 50,

Appendix A, General Design Criteria for Nuclear Power Plants, Criterion 16 - Containment design. Entergy itself acknowledges that [t]he primary containment function is to provide an essentially leak tight barrier against the uncontrolled release of radioactivity to the environment for postulated accidents. Attachment 1 to NL-14-128 at 17. Inspecting the IP2 containment less frequently than every 10 years is insufficient to assure that there is a leak-tight barrier against the controlled release of radioactivity to the environment.

4. ILRTs, also known as Type A leakage tests, are a safety tool that examines the comprehensive effectiveness of the containment liner and related containment components, structures, and systems. Testing for and preventing containment leakage provides assurance that the containment shell around the nuclear power reactor will perform its design function - to prevent or minimize the escape of radioactivity to the environment following an accident. Type A leak testing is especially important because it provides an opportunity to test and observe the effectiveness of the entire containment system under pressure. As such, the Type A test is 6

critical for providing reasonable assurance of adequate protection to New York citizens and communities near Indian Point.

5. Entergys evaluation of the safety risk posed by the reduced ILRT inspection frequency fails to consider the specific history of structural and corrosive damage to the IP2 containment liner. See Risk Assessment for Indian Point Regarding the ILRT (Type A)

Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-4 to 7-2. Although the LAR was submitted in December 2014, the risk assessment was completed a year earlier, in October 2013, for both IP2 and IP3. Id. at 1-1. Indeed, the Analysis of Proposed Technical Specification Changes Regarding 15 Year Containment ILRT notes that while the analysis presented in [the risk assessment] was performed for both IP2 and IP3, this submittal only addresses a LAR for IP2. The IP2 [sic] information presented in [the risk assessment] is therefore informational only and not part of the basis for the current LAR. NL-14-128, Attachment 1, at 15. It is not appropriate for Entergy to lump the risk assessment for IP2 and IP3 together, without considering the unique history of damaging events affecting the IP2 containment liner.

6. Entergys request to postpone the containment integrity testing ignores the prior determination of the AEC Staff that the IP2 containment liner should be subject to more frequent inspections due to its history of damage. See Letter from R.R. Maccary, Assistant Director for Engineering, Licensing, to Donald J. Skovhold, Assistant Director for Operating Reactors, Licensing (April 15, 1974), Attachment at 4 (ML093630690). This recommendation was made at a time when the Commissions regulations required three inspections every ten years. 60 Fed.

Reg. 49,495, 49,496 (Sept. 26, 1995). Entergy has failed to justify a departure from these initial requirements.

7

7. Entergys request to postpone the containment integrity testing ignores recent inspections that revealed significant corrosion and other wear in the containment liner. Visual inspections and ultrasonic testing of the IP2 containment liner in 2000 revealed that significant corrosion, resulting from a 1980 flooding event, had reduced the liner thickness to within.015 inches of the minimum required thickness. Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178). The LAR does not report on this corrosion, or indicate that tests were conducted to determine the current thickness of the liner. However, visual inspections of the IP2 containment liner in 2008, 2012, and 2014 revealed numerous other signs of degradation, including corrosion, buckling or loose plates, and leaking water. See Attachment 1 to NL 182, at 11-12. Because an ILRT has not been performed since 2006, it is unknown whether the conditions observed in 2008, 2012 and 2014 have compromised the integrity of the containment liner, such that radioactive materials could be released into the environment. See id. at 5. In fact, previous ILRTs indicate that the as found leakage has increased with every test, prompting NRC Staff to observe that the leakage rate is on a continuous trend towards eclipsing the IP2 acceptance criteria. NRC Staff, Request for Additional Information 4, at 3 (April 28, 2015)

(ML15103A259). Accordingly, delaying the next ILRT until 2021 will not provide a reasonable assurance of adequate protection of public health as required by AEA section 182(a) or 10 C.F.R

§ 50.40(a), which apply to license amendment requests pursuant to 10 C.F.R § 50.92(a).

8. Contrary to Entergys conclusions, Attachment 1 to NL-14-182, at 17-19, the LAR poses a significant hazard consideration under 10 C.F.R. § 50.92(c), for two reasons:
a. First, the failure to conduct an ILRT of the IP2 containment until 2021 involves a significant increase in the consequence of an accident previously evaluated under 10 8

C.F.R. § 50.92(c)(1). This is because the ILRT is the only method for testing the overall integrity of the IP2 containment liner. Considering the unique history of the IP2 containment liner and the visual signs of corrosion, wear and degradation observed during recent inspections, it is possible that the integrity of the liner has already been compromised, or will become compromised in the near future. Accordingly, the failure to conduct an ILRT until 2021 increases the consequences of a release of radiation from the reactor, since any such release might escape containment and reach the environment and citizens of the State in amounts that exceed NRC safety standards.

b. Second, the LAR involves a significant reduction in a margin of safety under 10 C.F.R. § 50.92(c)(3). By reducing the frequency of ILRTs, Entergy is necessarily reducing the margin of safety for containment integrity. If the 10-year inspection period were maintained, Entergy would be required to conduct two ILRTs during its 20-year period of extended operation,5 once in 2016 and a second time in 2026. However, if the LAR is granted, Entergy will only be required to conduct an ILRT once during the period of extended operation, in 2021.

Meanwhile, the IP2 containment is trending towards failing an ILRT by 2016, while the risk posed by seismic events is increasing. Considering that the IP2 containment liner will be over 60 years old by the end of the period of extended operation in 2033, and given the history of degradation experienced by the IP2 containment liner, one ILRT in 27 years of operation (2006 to 2033) represents a wholly inadequate safety margin. Additionally, although Entergy notes that Type B and Type C leakage tests will still be conducted every 60 months, these tests do not measure the overall integrity of the containment liner. See Attachment 1 to NL-14-128, at 6-9.

5 This assumes that the Commission grants the application to renew the IP2s initial 40 year operating license and authorizes the facility to operate for an additional term of up to 20 years; that application is subject to, among other things, a contested proceeding before a NRC Atomic Safety and Licensing Board in which the State has been participating since 2007.

9

By maintaining the existing Technical Specifications for ILRTs, Entergy will be required to test the IP2 containment in 2016, which will assure either that the containment remains within existing acceptance criteria, or that necessary repairs are made to bring the containment into compliance. A second ILRT no later than 2026 will further improve the safety margin, by evaluating whether the IP2 containment meets the applicable acceptance criteria as it nears the end of its (requested) period of extended operation.

9. The LAR also fails to adequately consider the risk that the degraded containment liner and related containment systems and components (including, but not limited to, welds, valves, fittings, vents, filters, circuits, and relays) will fail as a result of seismic activity at IP2. Recent analysis of IP2 reveals that it may be subjected to seismic events of greater intensity more frequently than thought at the time when IP2 received its construction permit in 1966 and its initial 40-year operating license in 1973. The LAR does not address these new seismic data. See to NL-14-182, at 5-26 to 5-31.
10. Entergys justification for reducing the frequency of this important safety-related test is wholly inadequate. Entergy claims that [t]he performance of fewer ILRTs would result in significant savings in radiation exposure to personnel, cost, and critical path time during future refueling outages. Attachment 1 to NL-14-128, at 3. Although minimizing worker exposure to radiation dose is important, reducing the number of required ILRTs - and corresponding worker exposure - to be conducted during the period of extended operation from two to one does not justify exposing millions of State citizens and resources to the risk of radiation escaping from a damaged containment structure. Entergys desire to reduce costs and maximize revenues also does not justify rolling back this important safety-related test. The requirement that Entergy conduct an ILRT every 10 years is part of the IP2 current licensing basis, and is an essential part 10

of NRCs obligation to ensure adequate protection of New York citizens and communities. It is well established that consideration of cost may not enter the NRC decision making when a requirement is part of the adequate protection licensing basis. As the U.S. Court of Appeals for the D.C. Circuit has ruled, [i]n setting or enforcing the standard of adequate protection that

[42 U.S.C. § 2232(a)] requires, the Commission may not consider the economic costs of safety measures. The Commission must determine, regardless of costs, the precautionary measures necessary to provide adequate protection to the public; the Commission then must impose those measures, again regardless of costs, on all holders of or applicants for operating licenses. Union of Concerned Scientists v. Nuclear Regulatory Commission, 824 F.2d 108, 114 (D.C. Cir. 1987).

Finally, the reduction of critical path time - in other words, an increase in plant outage time -

by the few days necessary to conduct an ILRT during refueling outages in 2016 and 2026 does not justify exposing millions of State citizens and the State environment to exposure from radiation escaping from a damaged containment structure.

11. Even assuming cost and increased outage time are relevant considerations in the Commissions consideration of Entergys LAR, Entergy has failed to provide a detailed cost analysis to support its assertion that there would be a considerable saving of time and money if the LAR is granted. Although the outage time and cost may increase if the IP2 containment fails the ILRT in 2016 and repairs are required, Entergy should not object to spending the time and money to make repairs that are necessary to assure the safe operation of IP2.

SUPPORTING EVIDENCE

12. Under 10 C.F.R § 50.92, [i]n determining whether an amendment to a license...

will be issued to the applicant, the Commission will be guided by the considerations which govern the issuance of initial licenses... to the extent applicable and appropriate. Under 11

section 182(a) of the Atomic Energy Act (AEA), 42 U.S.C. § 2232(a), a license application must include sufficient information to show that the issuance of the amendment will provide adequate protection to the health and safety of the public. Under 10 C.F.R. § 50.40(a) and (c),

the Commission, in order to grant a license application, must consider whether: (1) technical specifications... provide reasonable assurance that... the health and safety of the public will not be endangered; and (2) the issuance of the license to the applicant will not, in the opinion of the Commission, be inimical to the common defense and security or to the health and safety of the public.

13. An ILRT, also known as a Type A leakage rate test, is an comprehensive leakage rate test of the containment structure, which measures the integrated leakage rate from all potential leakage paths, including containment liner welds, valves, fittings, and components that penetrate containment. ILRT monitors for any leakage through the containment liner or other structural element due to corrosion or cracking. If a reactors containment liner and associated components, structures, and systems are in good order, a Type A leakage test could be performed in one or two days during a plant outage. If a Type A test identifies a leak, it may be necessary to devote additional time to identify, isolate, and repair the leak. The scope and frequency of Type A, Type B, and Type C leakage rate tests are governed by 10 C.F.R. Appendix J. Notably, the Type B and Type C leakage tests relate to containment penetrations, valves, and other discrete fittings and do not test the overall integrity of the containment liner itself. See to NL-14-128, at 6-9.
14. The history of the IP2 containment liner makes it particularly ill-suited for the reduced safety-margins proposed by Entergy. The IP2 containment structure is a steel-lined reinforced concrete vertical cylinder with a flat base mat and hemispherical dome that 12

completely encloses the entire reactor and reactor coolant system. The containment liner at IP2 is made from several pieces of welded steel, at least 1/4 thick, attached to the inside face of the concrete shell of the containment structure, and is intended to prevent radiation from escaping from IP2 and traveling into Westchester County and the New York City metropolitan area.

15. 1968 Incident. As early as 1968, when the IP2 containment structure was still under construction, plate buckling was detected in the IP2 containment liner in the vicinity of the fuel transfer tube canal penetration. See Report on the Containment Building Liner Plate Buckle in the Vicinity of the Fuel Transfer Canal (January 1968), at 1 (ML093521587). The buckled plates, discovered between elevations 56-7 and 59-7, exceeded the acceptable tolerance limits for local buckling. Id. at 3. The buckling was corrected by forcibly jacking the liner back within tolerance limits and installing strongback and stud anchors to hold the liner within the tolerance limits. Id. at 8. Accordingly, the IP2 containment liner was subjected to unusual stresses from its beginning.
16. 1973 Incident. On November 13, 1973, shortly after IP2 received its operating license, the IP2 containment liner was subject to further damage when the feedwater line to the No. 22 steam generator broke, causing a jet of steam and hot water to deform the containment liner. Letter from William J. Cahill, Jr., Vice-President, Consolidated Edison, to James P.

OReilly, Director, Regulatory Operations of Atomic Energy Commission (Nov. 30, 1973), at 2-3, 5 (ML093560700). Subsequent inspections determined that intermittent bulging extended over an arc of approximately 60 feet at an elevation of 73 in the containment liner. Consolidated Edison Company of New York, Inc., Feedwater Line Incident Report - Indian Point Unit No. 2 (Jan. 14, 1974), at 3-1 to 3-2 (ML100200180). The liner was pulled away from some of the anchor studs holding the liner to the concrete containment shell, and an ultrasonic inspection of 13

the damaged area revealed that 9 of the 18 studs in the bulged area were broken. Id. at 3-2. The ultrasonic inspection also revealed that the studs at this elevation were spaced at intervals of 28 inches, not the specified 14 inches - indeed, the inspection noted the unexplained absence of two rows of studs around the containment circumference. Id. Apparently, even when the containment liner was first installed in IP2, it did not conform with the applicable specifications.

17. Notwithstanding the large swath of damage to the liner resulting from the 1973 feedwater line failure or the mysterious absence of specified studs, the Consolidated Edison Company - the operator of IP2 at the time - told the AEC that the liner could continue to perform its function and that the original acceptance criteria for containment leakage were satisfied. Letter from William J. Cahill, Jr., Vice President, ConEd, to James P. OReilly, Director, Regulatory Operations of Atomic Energy Commission (March 12, 1974)

(ML093560204). The AEC Staff reviewing the incident agreed with ConEds conclusion.

Letter from R.R. Maccary, Assistant Director for Engineering, Licensing, to Donald J. Skovhold, Assistant Director for Operating Reactors, Licensing (April 15, 1974) (ML093630690).

However, AEC Staff recommended that because of this occurrence, increased attention should be given to the surveillance of the liner during the life of the plant and that the frequency of leakage tests required by the technical specification should be increased to a level above the three inspections per ten years then required by the Commissions regulations. Feedwater Line Incident Report (Jan. 14, 1974), attachment to id. at 4 (emphasis added); see 60 Fed. Reg.

49,495, 49,496 (Sept. 26, 1995) (reducing ILRT frequency from three inspections per 10 years to one inspection per 10 years). Despite the warnings from Staff that the frequency of leakage tests should be increased for the IP2 containment liner, the frequency of such tests has been steadily decreased from three per ten years, to once per ten years, and now - if the amendment request by 14

Entergy is granted - to once per fifteen years. See Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-1. Furthermore, Entergys request to extend the time between inspections from 10 to 15 years ignores the AEC Staff recommendation for increased attention to the surveillance of the liner during the life of the plant.

18. 1980 Containment Flooding Incident. The IP2 containment liner was subjected to further damage during a 1980 flooding event. An inspection of the containment structure conducted on October 17, 1980 discovered that leaking service water pipes had resulted in the containment area being flooded with more than 100,000 gallons of brackish water from the Hudson River. See NRC, IE Information Notice No. 80-37: Containment Cooler Leaks and Reactor Cavity Flooding at Indian Point Unit 2 (Oct. 25, 1980) (ML031180421). This event resulted in the corrosion of the containment liner at the 46 foot elevation, where it meets the concrete containment floor. See Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178).
19. Revision of Seismic Hazard. Entergy recently provided an updated seismic hazard analysis for IP2. That analysis shows that the anticipated ground motion is larger for higher frequency events than was understood when IP2 received its operating license in 1973. After receiving the Entergy updated analysis, NRC Staff performed its own analysis. The recently-produced ground motion curves appear to be higher than the Safe Shutdown Earthquake (or SSE) design curves that resulted from licensing hearings in the 1970s and were adopted by the Commission. See NRC Staff, Slides, Near-Term Task Force Recommendation 2.1: Entergy, at 6 (June 19, 2014) (ML14169A489).

15

Id. The new revised seismic curves reflect a significantly greater seismic risk for certain systems, structures, and components at IP2 when compared to IP2s original safe shutdown earthquake.

Accordingly, Staff placed IP2 in the Priority Group 1 for additional review. According to Staff, Group 1 plants are generally those that have the highest re-evaluated hazard relative to the original plant seismic design basis as well as ground motions in the 1-10Hz range that are generally higher in absolute magnitude. Group 1 plants are expected to conduct a seismic risk evaluation and submit it by June 30, 2017. NRC Staff, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluations for Operating Reactors in the Central and Easter United Sates, at 2 (May 21, 2014) (ML14136A126).

20. ILRT Results. Published ILRT results indicate that the integrity of the IP2 containment has steadily declined between 1979 and 2006, and is on pace to not meet the applicable acceptance criteria by 2016. The containment leak rate has increased every time the 16

ILRT has been conducted, even as the test pressure (psia) has generally been lowered. to NL-14-128, at 5-6. Indeed, NRC Staff has noted that the historical trend indicates that consistently, for all five historical ILRTs, the As found Leakage is on a continuous trend towards eclipsing the IP2 [Technical Specification] 5.5.14.d.1 leakage rate acceptance criteria of 0.75 La (i.e., 0.075 percent containment weight per day). NRC Staff, Request for Additional Information 4, at 3 (April 28, 2015) (ML15103A259). Table 1 shows the results of the most recent ILRTs.

DATE LEAKAGE RATE

(% Containment Weight per Day)

TEST PRESSURE (PSIA) 1979 August 0.0260 62.7 1984 September 0.0320 65.6 1987 December 0.0342 62.9 1991 June 0.0478 61.7 2006 April 0.0636 60.5 Table 1. Source: Attachment 1 to NL-14-128, at 5-6.

In the 27 years between the 1979 ILRT and the 2006 ILRT, the leakage rate has increased by an average of 0.0014% per year ([0.0636-0.0260]/27). Assuming that leakage rate has not increased since 2006, the expected leakage rate for an ILRT conducted in 2016 would be 0.078 (0.0014*10+0.0636), exceeding the current Technical Specifications leakage rate acceptance criteria of 0.75 La (i.e., 0.075 percent containment weight per day).

21. Recent Inspection History. Recent inspections of the IP2 containment surfaces, including the containment liner, confirm that the liner and related surfaces have been harmed by the historical accidents. An inspection of the liner plate conducted during the 2000 refueling outage revealed (1) coating deterioration and minor corrosion on 40 out of 116 electrical and 17

mechanical penetrations; (2) coating degradation and minor corrosion at elevation 134 ft.; (3) portions of the moisture barrier at the liner basemat interface were deteriorated; (3) liner corrosion between 2 in. above and 3 in. below the concrete containment floor, which had resulted from [the 1980 containment flooding incident] See Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178). Ultrasonic testing (UT) of the corroded liner plates near the containment floor determined that the liner thickness had deteriorated from.5 inches to.355 inches in one location, which was only.015 inches thicker than the minimum required liner thickness established by the consultant conducting the test. Id. Although NRC Staff determined that the corroded liner nevertheless provided an adequate safety margin at that time -

15 years ago - Entergy has not submitted up-to-date information regarding the current thickness of the liner plate in that area. See Attachment 2 to NL-14-182, at 10-14 (describing various visual inspection results, but no UT testing).

22. In 2008, the visual inspection of containment surfaces, including the containment liner, showed general surface corrosion, minor coating peeling/flaking, blistered paint, loose stainless steel insulation panels and buckling stainless steel insulation panels (VC liner inaccessible) at columns 10 and 11 elevation 68. Attachment 2 to NL-14-128, at 11. Two damaged areas of the stainless steel insulation jacket had to be repaired at this time. Id. at 12. In 2012, inspectors found many of the same conditions, and also observed water seeping adjacent to penetration #69 in the containment building, attributed to repairs that had been conducted in 2000. Id. A 2014 visual inspection confirmed the presence of many of the same conditions, although not the leaking water. Id. Notably, because the last ILRT was performed in 2006, it is 18

unknown whether the wear, leaking water, or loose and buckling panels observed in these visual inspections would result in the failure of an ILRT. See id. at 5.

23. The Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request is based in part on an NRC report on performance based leak testing, NUREG-1493, which analyzed the effects of containment leakage on the health and safety of the public and the benefits realized from containment leak rate testing using a representative PWR plant. Attachment 3 to NL-14-182, at 1-1 to 1-2. That representative plant was the Surry reactor, located in rural Virginia. Id. It is wholly inappropriate to use Surry as a benchmark plant and site for regulatory analysis in a license amendment for IP2, which is located in a densely populated urban and suburban environment and has been subjected to various unique degradation events. See USNRC, Generic Environmental Impact Statement for License Renewal of Nuclear Plants, NUREG-1437, Table 2-1 (1996) (identifying surrounding populations at reactor sites).
24. Deficiencies in the Referenced Severe Accident Analysis. The request to amend the IP2 operating license relies on the 2009 Severe Accident Mitigation Alternatives (SAMA)

Reanalysis, but that analysis omits important considerations and contains erroneous assumptions and inputs.6 Those omissions and errors work to undercount the costs of an offsite radiation release and therefore skew the cost benefit analysis in favor of the requested amendment. By 6 See, e.g., Attachment 3 to NL-14-128, Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request (October 2013) at p. 3-1 (referencing SAMA analysis), 8-1 (reference no. 10 Re-analysis of MACCS2 Models for IPEC, Calculation IP-CALC-09-00265, December 2009); see also, e.g., 8-2 (references n. 20 Appendix E of Applicants Environmental Report for License Renewal Application (April 2007); Attachment 1 to NL-14-128, Analysis of Proposed Technical Specification Changes Regarding 15 Year Containment Test at 16 (referencing License Renewal SAMA analysis). In addition the operating license amendment request references information at p. 3-1 (referencing MACCS2 off-site consequence runs), and 8-1 (reference no. 11 MAAP/MACCS2 Computer Codes Calculated Dose for IPEC Containment Structure Based on Allowable Leakage From an Intact Containment, Calculation IP-CALC-13-00042, September 2013), but this document and associated computer runs are not part of the operating license amendment application. Because this information did not accompany the license amendment request, the State was unable to review and analyze it in preparation for this petition. The State reserves the right to supplement its filings when the information becomes public.

19

way of example, the SAMA analysis does not take into account the value or decontamination cost of offsite properties with iconic value such as landmarks and national monuments, natural resources such as public drinking water reservoirs, or critical regional, state, or national infrastructure. In addition, the analysis artificially and improperly limits its scope to land and population only within 50 miles of the site (distance truncation) and relied on a dollar per person rem value of $2,000, a value which is out of date and should be increased. In support of the petition to intervene and the contentions, the State includes Attachment 1, which identifies some of the unique sites in the New York metropolitan area, and Attachment 2, which depicts the location of reservoirs relative to the Indian Point site.

CONTENTION NYS-2 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specifications Should Be Denied Because Entergy Has Not Submitted an Environmental Report as Required By 10 C.F.R §§ 51.53 and It Has Not Undergone the Required NRC Staff Environmental Review Pursuant to 10 C.F.R § 51.101 and, Despite Entergys Claim to the Contrary, the Proposed Amendment Is Not Categorically Exempt from That Review Under 10 C.F.R. § 51.22(c)(9).

BASES

1. The National Environmental Policy Act (NEPA) and applicable NRC regulations require at least some level of environmental review before the NRC acts on matters potentially affecting the environment. Entergy asserts that its LAR is categorically exempt from environmental review under 10 C.F.R. 51.22(c)(9), because [t]he proposed changes to the IP2

[Technical Specification] do not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation 20

exposure. Attachment 1 to NL-14-182, at 19. This categorical exemption does not apply, because the LAR involves a significant hazards consideration.

2. Contrary to Entergys conclusions, Attachment 1 to NL-14-182, at 17-19, the LAR poses a significant hazard consideration under 10 C.F.R. § 50.92(c), for two reasons:
a. First, the failure to conduct an ILRT of the IP2 containment until 2021 involves a significant increase in the consequence of an accident previously evaluated under 10 C.F.R. § 50.92(c)(1). This is because the ILRT is the only method for testing the overall integrity of the IP2 containment liner. Considering the unique history of the IP2 containment liner and the visual signs of corrosion, wear and degradation observed during recent inspections, it is possible that the integrity of the liner has already been compromised, or will become compromised in the near future. Accordingly, the failure to conduct an ILRT until 2021 increases the consequences of a release of radiation from the reactor, since any such release might escape containment and reach the environment and citizens of the State in amounts that exceed NRC safety standards.
b. Second, the LAR involves a significant reduction in a margin of safety under 10 C.F.R. § 50.92(c)(3). By reducing the frequency of ILRTs, Entergy is necessarily reducing the margin of safety for containment integrity. If the 10-year inspection period were maintained, Entergy would be required to conduct two ILRTs during its 20-year period of extended operation, once in 2016 and a second time in 2026. However, if the LAR is granted, Entergy will only be required to conduct an ILRT once during the period of extended operation, in 2021.

Meanwhile, the IP2 containment is trending towards failing an ILRT by 2016, while the risk posed by seismic events is increasing. Considering that the IP2 containment liner will be over 60 years old by the end of the period of extended operation in 2033, and given the history of degradation experienced by the IP2 containment liner, one ILRT in 27 years of operation (2006 21

to 2033) represents a wholly inadequate safety margin. Additionally, although Entergy notes that Type B and Type C leakage tests will still be conducted every 60 months, these tests do not measure the overall integrity of the containment liner. See Attachment 1 to NL-14-128, at 6-9.

By maintaining the existing Technical Specifications for ILRTs, Entergy will be required to test the IP2 containment in 2016, which will assure either that the containment remains within existing acceptance criteria, or that necessary repairs are made to bring the containment into compliance. A second ILRT no later than 2026 will further improve the safety margin, by evaluating whether the IP2 containment meets the applicable acceptance criteria as it nears the end of its period of extended operation.

3. Because the LAR involves a significant hazards consideration, it does not qualify for the categorical exemptions from environmental review under 10 C.F.R. 51.22(c)(9).

Accordingly, the Commission cannot act on the LAR until an environmental review is complete.

See 10 C.F.R. § 51.101(a)(1).

4. The following bases, offered above in support of Contention NYS-1, are relevant to this contention and are incorporated here by reference: 1-4, and 8.

SUPPORTING EVIDENCE

5. NEPA requires federal agencies to prepare a detailed statement... on the environmental impact of any proposed major federal action significantly affecting the quality of the human environment. 42 U.S.C. § 4332(1)(C)(i). At a minimum, if any agency is going to allow a licensee to engage in activities with environmental impacts without the agency first issuing a detailed environmental impact statement, the agency must do an environmental analysis and issue a finding of no significant impact (FONSI). 40 C.F.R. § 1501.4.

22

6. The NEPA requirements are incorporated into NRC regulations. See 10 C.F.R. Part 51, Subpart A. In general, if a licensing or regulatory action undertaken by NRC is not subject to a categorical exclusion under section 51.22(c) or (d), an environmental impact statement (EIS) under section 51.20(b) or an environmental assessment under section 51.21 is required. Under section 51.101(a), if a proposed licensing or regulatory action requires an environmental impact statement or environmental assessment, the Commission may take [n]o action on the proposal which would (i) have an adverse environmental impact, or (ii) limit the choice of reasonable alternatives until the EIS is complete or a FONSI is made.
7. The following supporting evidence underlying Contention NYS-1, above, is also relevant to this Contention, and is incorporated here by reference: 12-22.

CONCLUSION The States contentions raise a genuine dispute of material law or fact on whether Entergy is entitled to the LAR. Accordingly, the NRC should grant the States Motion for Leave to Intervene and schedule a hearing on the LAR.

Dated: Albany, New York May 18, 2015 Respectfully submitted, Signed (electronically) by John J. Sipos Brian Lusignan Assistant Attorneys General Office of the Attorney General of the State of New York The Capitol Albany, New York 12224 (518) 776-2380 john.sipos@ag.ny.gov brian.lusignan@ag.ny.gov 23

DESIGNATION OF REPRESENTATIVE FOR SERVICE Pursuant to 10 C.F.R. §§ 2.304 (e) and 2.309(h), the State of New York designates the following representative as a person on whom service may be made:

John J. Sipos Assistant Attorney General Office of the Attorney General of the State of New York The Capitol Albany, New York 12224-0341 (518) 776-2380 john.sipos@ag.ny.gov 24

ATTACHMENT 1 List of Historic, Unique or Otherwise Significant Sites within 50 Miles of Indian Point

List of Various Site Specific Improvements, Including Landmarks, Parks, Arenas, Universities, and Transportation Facilities Within 50 Miles of Indian Point Power Reactors and Spent Fuel Facilities National Historic Landmarks:

Brooklyn Bridge Carnegie Hall Central Synagogue Central Park Cooper Union New York Stock Exchange Grand Central Terminal Guggenheim Museum Metropolitan Museum of Art New York Public Library New York Botanical Garden Governors Island New York City Hall Union Square St Patrick's Cathedral Trinity Church Stony Point Battlefield National Parks:

Statue of Liberty National Monument (& Ellis Island)

Saint Paul's Church National Historic Site Appalachian National Scenic Trail General Ulysses S. Grant National Memorial Home of Franklin D.

Roosevelt National Historic Site Vanderbilt Mansion National Historic Site African Burial Ground National Monument Castle Clinton National Monument Governors Island National Monument Federal Hall National Memorial Hamilton Grange National Memorial Gateway National Recreation Area Sagamore Hill National Historic Site Other One World Trade Center Brooklyn Navy Yard Jacob K Javits Convention Center Flushing Meadows-Corona Park Lincoln Center for the Performing Arts Manhattan Municipal Building Outdoor Sports Venues Yankee Stadium Citi Field USTA Billie Jean King National Tennis Center Icahn Stadium Aviator Arena Barclay's Center (under construction)

Hamilton-Metz Field MCU Park Arnold and Marie Schwartz Athletic Center Aqueduct Racetrack Metropolitan Oval Universities United States Military Academy (West Point)

United States Merchant Marine Academy Columbia University New York University Fordham University The Juliard School Culinary Institute of America St. John's University Yeshiva University Brooklyn Law School Brooklyn College CUNY (all campuses)

Vassar College Pace University Pratt Institute Yeshiva University Transportation South Ferry Terminal Howland Hook Marine Terminal Red Hook Container Terminal Brooklyn Marine Terminal New York Passenger Ship Terminal Brooklyn Cruise Terminal Newburgh-Beacon Bridge Bear Mountain Bridge Mid Hudson Bridge Verrazanno Narrows Bridge George Washington Bridge Brooklyn Bridge Manhattan Bridge Williamsburg Bridge Throgs Neck Bridge Robert F. Kennedy Bridge Queensboro Bridge Bronx-Whitestone Bridge Dutchess County Airport Stewart Airport Teterboro Airport Laguardia Airport JFK Airport Westchester County Airport Pennsylvania Station World Trade Center PATH Station Interstate I-95, I-287, I-87 (NYS Thruway),

I-84, NYS Route 9, Taconic Parkway

List of Various Site Specific Improvements, Including Landmarks, Parks, Arenas, Universities, and Transportation Facilities Within 50 Miles of Indian Point Power Reactors and Spent Fuel Facilities New York City Parks:

Randalls Island Park Battery Park Washington Square Park Madison Park Fort Tyron Park The High Line Highbridge Park The Cloisters Bronx Zoo Van Cortlandt Park Prospect Park Bryant Park Jacob Purdy House Fort Wadsworth Jamaica Bay Wildlife Refuge State Parks:

Bayswater Point Clay Pit Ponds East River Empire-Fulton Ferry Gantry Plaza Riverbank Roberto Clemente Clarence Fahnestock Fahnestock Winter Park Franklin D. Roosevelt Hudson Highlands James Baird Mills Norrie (Margaret Lewis Norrie)

Ogden Mills & Ruth Livingston Mills Old Croton Aqueduct Rockefeller Walkway Over the Hudson (Poughkeepsie)

Clinton House John Jay Homestead Philipse Manor Hall Staatsburgh State Historic Site Anthony Wayne Recreation Area Bear Mountain Beaver Pond Campgrounds Blauvelt Goosepond Mountain Harriman High Tor Highland Lakes Lake Sebago Beach Lake Tiorati Beach Lake Welch Beach Minnewaska Preserve Nyack Beach Rockland Lake Schunnemunk Silver Mine Sterling Forest Storm King Tallman Mountain Fort Montgomery Knox's Headquarters National Purple Heart Hall of Honor New Windsor Cantonment Stony Point Battlefield Washington's Headquarters Bethpage Golf Course Caumsett Planting Fields Arboretum Walt Whitman Birthplace Prepared by Adam Solomon

ATTACHMENT 2 Map of Reservoirs in Vicinity of Indian Point

DISTANCE TO NEW YORK RESERVOIRS FROM INDIAN POINT NUCLEAR FACILITIES

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION


x In the Matter of:

Docket No. 50-247-LA License Amendment Request of Entergy Nuclear License No. DPR-26 Operations, Inc. dated December 9, 2014, for Indian Point Nuclear Generating Unit No. 2 to Postpone Testing of Containment Integrity May 18, 2015


x CERTIFICATE OF SERVICE I hereby certify that on May 18, 2015, copies of the State of New Yorks Petition to Intervene and Request for Hearing were served electronically via the Electronic Information Exchange on the following recipients:

E. Roy Hawkens Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Mailstop 3 F23 Two White Flint North 11545 Rockville Pike Roy.Hawkens@nrc.gov Office of Commission Appellate Adjudication U.S. Nuclear Regulatory Commission Mailstop 16 G4 One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 ocaamail@nrc.gov Office of the Secretary Attn: Rulemaking and Adjudications Staff U.S. Nuclear Regulatory Commission Mailstop 3 F23 Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 hearingdocket@nrc.gov Clara.Sola@nrc.gov Sherwin E. Turk, Esq.

David E. Roth, Esq.

Beth N. Mizuno, Esq.

Brian G. Harris, Esq.

Anita Ghosh, Esq.

Edward Williamson, Esq.

John Tibbets Office of the General Counsel U.S. Nuclear Regulatory Commission Mailstop 15 D21 One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 sherwin.turk@nrc.gov david.roth@nrc.gov beth.mizuno@nrc.gov brian.harris@nrc.gov anita.ghosh@nrc.gov Edward.Williamson@nrc.gov John.Tibbets@nrc.gov Jeanne Cho Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Jcho1@entergy.com 1

Paul M. Bessette, Esq.

Raphael Kuyler, Esq.

Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 pbessette@morganlewis.com rkuyler@morganlewis.com John Sipos, Esq.

Lisa Kwong, Esq.

Brian Lusignan, Esq.

Office of the Attorney General of the State of New York The Capitol Albany NY 12224 John.Sipos@ag.ny.gov Lisa.Kwong@ag.ny.gov Brian.Lusignan@ag.ny.gov Signed (electronically) by Brian Lusignan Assistant Attorney General State of New York (518) 776-2399 Brian.Lusignan@ag.ny.gov Dated at Albany, New York This 18th day of May, 2015 2

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of:

License Amendment Request of Entergy Nuclear Operations, Inc., dated December 9, 2014, for Indian Point Nuclear Generating Unit No.2 to Postpone Testing of Containment Integrity Docket No. 50-247-LA License No. DPR-26 May 18, 2015 STATE OF NEW YORK PETITION TO INTERVENE AND REQUEST FOR HEARING Office of the Attorney General for the State of New York The Capitol State Street Albany, New York 12224

Table of Contents INTRODUCTION......................................................................................................................... 1 STANDING................................................................................................................................... 2 CONTENTION NYS-1................................................................................................................. 5 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specification Should Be Denied Because It Involves a Significant Safety and Environmental Hazard, Fails to Demonstrate That It Complies with 10 C.F.R. §§ 50.40 and 50.92 or 10 C.F.R 50, Appendix J, and Fails to Demonstrate That It Will Provide Reasonable Assurance of Adequate Protection for the Public Health and Safety as Required by Section 182(a) of the Atomic Energy Act (42 U.S.C. § 2232[a]) if the Proposed Amendment to the Operating License Is Approved................................................................................................................... 5 BASES........................................................................................................................................ 5 SUPPORTING EVIDENCE.................................................................................................. 11 CONTENTION NYS-2............................................................................................................... 20 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specifications Should Be Denied Because Entergy Has Not Submitted an Environmental Report as Required By 10 C.F.R §§ 51.53 and It Has Not Undergone the Required NRC Staff Environmental Review Pursuant to 10 C.F.R § 51.101 and, Despite Entergys Claim to the Contrary, the Proposed Amendment Is Not Categorically Exempt from That Review Under 10 C.F.R. § 51.22(c)(9)............................................................................................................. 20 BASES...................................................................................................................................... 20 SUPPORTING EVIDENCE.................................................................................................. 22 CONCLUSION........................................................................................................................... 23 ii

INTRODUCTION Pursuant to 10 C.F.R. § 2.309, the State of New York (the State) seeks leave to intervene and requests a hearing with respect to an operating license amendment request (or LAR) submitted by Entergy Nuclear Operations, Inc. (Entergy) on December 9, 2014 and published in the Federal Register on March 17, 2015. See 80 Fed. Reg. 13,902 (March 17, 2015). Entergy seeks to postpone an important safety obligation that tests the integrity of the Indian Point Unit 2 containment system from early 2016 to 2021 and thereafter to perform the containment vessel integrity test once in every 15 years. Entergys LAR would increase the risk that the citizens and environment of the State will be exposed to the release of radioactive materials. In evaluating this risk, Entergy ignored important plant-specific circumstances and events that have weakened and damaged key containment components, as well as recent updates indicating elevated seismic hazards at the Indian Point site. Moreover, Entergy failed entirely to conduct any environmental review of its LAR. Because these shortcomings would prevent the NRC from making the findings necessary to grant the LAR, the State should be permitted to intervene and request a hearing with respect to the LAR.

On December 9, 2014, Entergy submitted a request seeking NRC authorization to amend Operating License DPR-26 for the Indian Point Nuclear Generating Unit No. 2 (IP2), Docket No.

50-247, to obtain a permanent extension of the frequency with which it must conduct a containment integrated leak rate test (or ILRT) from 10 years to 15 years.1 Letter from Lawrence Coyle, Site Vice President, Entergy Nuclear Northeast, to U.S. Nuclear Regulatory Commission, NL-14-128 (Dec. 9, 2014) (ML14353A015). The ILRT is an important test of containment integrity that protects the environment and members of the public from exposure to 1 Entergy had obtained a one-time extension of the ILRT frequency from 10 to 15 years in 2002. See Letter from Patrick D. Milano, Office of Nuclear Reactor Regulation, to Michael R. Kansler, Entergy (Aug. 5, 2002)

(ML021860178).

1

uncontrolled releases of radiation from the reactor. Despite its importance, since 1995, Entergy and its predecessor licensee have steadily reduced the frequency with which this leak test has been conducted, from three inspections per ten years, to one inspection per ten years, to a one-time extension to once every 15 years, and now - if Entergys LAR is granted - to once per fifteen years on a permanent basis.2 See Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-1. If the LAR is granted, the IP2 containment will next be inspected in 2021 - rather than 2016 - and, after that, will likely not be inspected again for the remaining life of the plant.

The IP2 containment liner, in particular, has been subjected to a variety of unusual degradation events over more than four decades, including buckling in 1968, deformations caused by a jet of steam and hot water in 1973, and corrosion due to a flooding event in 1980. Entergys license amendment application fails to mention, let alone consider, these plant-specific events, presenting instead a generic analysis.

STANDING The State of New York and its citizens have a direct interest in ensuring the safe operation of IP2 in Buchanan, New York, and meet all the requirements for intervenor standing under 10 C.F.R. § 2.309(d)(1).3 As required by 10 C.F.R. § 2.309(d)(1)(ii), the State has a clear right under the Atomic Energy Act (AEA) to be made a party to this proceeding. The State seeks leave to assert that the 2 The State of New York has previously expressed its concerns with extending the period between ILRTs for IP3.

See New York State Comments on Indian Point 3 Proposed License Amendment Regarding Extending the Containment Type A Leak Rate Testing Frequency to 15 Years (February 2015) (ML15055A512). Nonetheless, the NRC approved Entergys prior request to increase the period between ILRTs from once per 10 years to once per 15 years. See Letter from Douglas Pickett, Office of Nuclear Reactor Regulation, to Vice President of Operations, Entergy (March 13, 2015) (ML15028A308).

3 Section 2.309(d)(1)(i) requires a proposed intervenor set forth its name, address and telephone number[.] To the extent that this requirement applies to a State intervenor, the contact information for the States representatives can be found at the end of this Petition.

2

LAR (1) does not provide a reasonable assurance of adequate protection of public health under the Atomic Energy Act § 182(a), 42 U.S.C. § 2232(a), (2) does not comply with NRC regulations applicable to license amendment requests including 10 C.F.R. §§ 50.40 and 50.92 and 10 C.F.R 50, Appendix J, (3) involves a significant safety and environmental hazard, and (4) does not qualify for a categorical exemption to the preparation of an environmental review as required by the National Environmental Protection Act (NEPA) and implemented by NRC regulations.

Additionally, as required by 10 C.F.R. §§ 2.309 (d)(1)(iii), the State has extensive property, financial or other interest[s] that are implicated by the license amendment request.

IP2 is located just twenty-four miles north of New York City, in one of the most densely populated parts of the State or, indeed, the country. The IP2 reactor is also 6 miles west of the New Croton Reservoir in Westchester County, which is part of the New York City reservoir system and provides drinking water to New York City residents and is close to other reservoirs in the New York metropolitan area. The 50-mile area around IP2 contains some of the densest real estate development in the country, numerous landmarks, iconic and irreplaceable sites, and vital components of the State and Nations critical infrastructure. A list of historic, unique or otherwise significant sites within 50 miles of the IP2 site is attached as Attachment 1. A map of reservoirs in the vicinity of the IP2 site is attached as Attachment 2. In addition, the facility is located on the States Hudson River - an important waterway for commercial, environmental and recreational reasons - and relies on river water for steam generation and cooling.

Finally, as required by 10 C.F.R. § 2.309(d)(1)(iv), the States interests will be directly affected if the license amendment request is granted. Entergys LAR seeks to reduce the frequency of an important test of containment integrity. If a breach of containment integrity goes 3

undetected due to the reduced inspection frequency proposed by Entergy, the States citizens and environment could be exposed to an uncontrolled release of radiation. Millions of the States citizens live within 50 miles of IP2, and would be at risk of exposure to harmful radiation if such a release were to occur. Additionally, billions of dollars in property, including the countrys financial center, are located within 50 miles of IP2, and would be adversely affected by exposure to radiation. NRC Commissioners have recognized that given its location, a severe release of radioactive materials at Indian Point could have more serious consequences than that same release at virtually any other NRC-licensed site. Consolidated Edison Co. of N.Y. (Indian Point Unit 2) and Power Auth. of the State of New York (Indian Point Unit 3), CLI-85-6, 21 N.R.C. 1043, 1049-50 (1985).

Entergys request to delay and defer the containment integrity test has failed to consider a number of plant-specific events that render the IP2 containment ill-suited for a relaxation of inspection frequency. Moreover, Entergy has failed to conduct any environmental analysis of the license amendment request, and - contrary to Entergys claim - it is not categorically excluded from this requirement. Accordingly, the risk posed by an undetected loss of containment integrity to the States environment and natural resources has not been properly evaluated. The States interest in ensuring that those risks - and alternatives thereto -

are properly identified, assessed, and mitigated is manifest.

NRC has previously recognized the States interest and standing to participate in proceedings concerning the Indian Point nuclear facilities. See Entergy Nuclear Operations, Inc.

(Indian Point, Units 2 and 3), LBP-08-13 at 5, 68 N.R.C. 43 (July 31, 2008).

4

CONTENTION NYS-1 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specification Should Be Denied Because It Involves a Significant Safety and Environmental Hazard, Fails to Demonstrate That It Complies with 10 C.F.R. §§ 50.40 and 50.92 or 10 C.F.R 50, Appendix J, and Fails to Demonstrate That It Will Provide Reasonable Assurance of Adequate Protection for the Public Health and Safety as Required by Section 182(a) of the Atomic Energy Act (42 U.S.C. § 2232[a]) if the Proposed Amendment to the Operating License Is Approved.

BASES

1. In 1956, the federal Atomic Energy Commission (AEC)4 approved the Indian Point site for nuclear power reactorsbefore the government had promulgated regulations for the siting of such facilities. See 21 Fed. Reg. 3,085 (May 9, 1956). In 1966, AEC issued a construction permit for Indian Point Unit 2. See 31 Fed. Reg. 13,616-17 (Oct. 21, 1966). The Consolidated Edison Company of New York (Con Edison) undertook construction activities including the construction and fabrication of the containment liner and related systems, structures, and components. AEC subsequently issued an operating license (DPR-26) for the facility in 1973.

See e.g. 38 Fed. Reg. 27,636 (Oct. 5, 1973). The operating license contains, among other things, binding and enforceable technical specifications.

2. Entergy seeks to amend a technical specification pursuant to 10 C.F.R 50, Appendix J, Option B in order to reduce the frequency of the only inspection that tests the overall integrity of the IP2 containment liner. According to IP2s current licensing basis, the next ILRT should be conducted in 2016, followed by another inspection in 2026. Entergy proposes, instead, to conduct an ILRT once in 2021 and not again during the remaining operating life of the plant (2033). During its construction and 42 years of operation, the IP2 containment liner has been 4 The U.S. Atomic Energy Commission was the predecessor to the U.S. Nuclear Regulatory Commission.

5

subjected to a series of damaging incidents, making it ill-suited for the relaxed monitoring proposed by Entergy. Entergy claims that Option B of Appendix J dictates that the frequency of Type A leakage tests should be based on plant-specific performance data and on consideration of the operating history of the component and the resulting risk from its failure. to NL-14-182, at 2 (citing 10 C.F.R. 50 Appendix J, NEI 94-01 Revision 2A, and Regulatory Guide 1.163). However, Entergy has failed to consider the plant-specific history of the IP2 containment liner.

3. Reactor containment and associated systems shall establish a leak-tight barrier against the controlled release of radioactivity to the environment. See, e.g., 10 C.F.R. Part 50,

Appendix A, General Design Criteria for Nuclear Power Plants, Criterion 16 - Containment design. Entergy itself acknowledges that [t]he primary containment function is to provide an essentially leak tight barrier against the uncontrolled release of radioactivity to the environment for postulated accidents. Attachment 1 to NL-14-128 at 17. Inspecting the IP2 containment less frequently than every 10 years is insufficient to assure that there is a leak-tight barrier against the controlled release of radioactivity to the environment.

4. ILRTs, also known as Type A leakage tests, are a safety tool that examines the comprehensive effectiveness of the containment liner and related containment components, structures, and systems. Testing for and preventing containment leakage provides assurance that the containment shell around the nuclear power reactor will perform its design function - to prevent or minimize the escape of radioactivity to the environment following an accident. Type A leak testing is especially important because it provides an opportunity to test and observe the effectiveness of the entire containment system under pressure. As such, the Type A test is 6

critical for providing reasonable assurance of adequate protection to New York citizens and communities near Indian Point.

5. Entergys evaluation of the safety risk posed by the reduced ILRT inspection frequency fails to consider the specific history of structural and corrosive damage to the IP2 containment liner. See Risk Assessment for Indian Point Regarding the ILRT (Type A)

Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-4 to 7-2. Although the LAR was submitted in December 2014, the risk assessment was completed a year earlier, in October 2013, for both IP2 and IP3. Id. at 1-1. Indeed, the Analysis of Proposed Technical Specification Changes Regarding 15 Year Containment ILRT notes that while the analysis presented in [the risk assessment] was performed for both IP2 and IP3, this submittal only addresses a LAR for IP2. The IP2 [sic] information presented in [the risk assessment] is therefore informational only and not part of the basis for the current LAR. NL-14-128, Attachment 1, at 15. It is not appropriate for Entergy to lump the risk assessment for IP2 and IP3 together, without considering the unique history of damaging events affecting the IP2 containment liner.

6. Entergys request to postpone the containment integrity testing ignores the prior determination of the AEC Staff that the IP2 containment liner should be subject to more frequent inspections due to its history of damage. See Letter from R.R. Maccary, Assistant Director for Engineering, Licensing, to Donald J. Skovhold, Assistant Director for Operating Reactors, Licensing (April 15, 1974), Attachment at 4 (ML093630690). This recommendation was made at a time when the Commissions regulations required three inspections every ten years. 60 Fed.

Reg. 49,495, 49,496 (Sept. 26, 1995). Entergy has failed to justify a departure from these initial requirements.

7

7. Entergys request to postpone the containment integrity testing ignores recent inspections that revealed significant corrosion and other wear in the containment liner. Visual inspections and ultrasonic testing of the IP2 containment liner in 2000 revealed that significant corrosion, resulting from a 1980 flooding event, had reduced the liner thickness to within.015 inches of the minimum required thickness. Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178). The LAR does not report on this corrosion, or indicate that tests were conducted to determine the current thickness of the liner. However, visual inspections of the IP2 containment liner in 2008, 2012, and 2014 revealed numerous other signs of degradation, including corrosion, buckling or loose plates, and leaking water. See Attachment 1 to NL 182, at 11-12. Because an ILRT has not been performed since 2006, it is unknown whether the conditions observed in 2008, 2012 and 2014 have compromised the integrity of the containment liner, such that radioactive materials could be released into the environment. See id. at 5. In fact, previous ILRTs indicate that the as found leakage has increased with every test, prompting NRC Staff to observe that the leakage rate is on a continuous trend towards eclipsing the IP2 acceptance criteria. NRC Staff, Request for Additional Information 4, at 3 (April 28, 2015)

(ML15103A259). Accordingly, delaying the next ILRT until 2021 will not provide a reasonable assurance of adequate protection of public health as required by AEA section 182(a) or 10 C.F.R

§ 50.40(a), which apply to license amendment requests pursuant to 10 C.F.R § 50.92(a).

8. Contrary to Entergys conclusions, Attachment 1 to NL-14-182, at 17-19, the LAR poses a significant hazard consideration under 10 C.F.R. § 50.92(c), for two reasons:
a. First, the failure to conduct an ILRT of the IP2 containment until 2021 involves a significant increase in the consequence of an accident previously evaluated under 10 8

C.F.R. § 50.92(c)(1). This is because the ILRT is the only method for testing the overall integrity of the IP2 containment liner. Considering the unique history of the IP2 containment liner and the visual signs of corrosion, wear and degradation observed during recent inspections, it is possible that the integrity of the liner has already been compromised, or will become compromised in the near future. Accordingly, the failure to conduct an ILRT until 2021 increases the consequences of a release of radiation from the reactor, since any such release might escape containment and reach the environment and citizens of the State in amounts that exceed NRC safety standards.

b. Second, the LAR involves a significant reduction in a margin of safety under 10 C.F.R. § 50.92(c)(3). By reducing the frequency of ILRTs, Entergy is necessarily reducing the margin of safety for containment integrity. If the 10-year inspection period were maintained, Entergy would be required to conduct two ILRTs during its 20-year period of extended operation,5 once in 2016 and a second time in 2026. However, if the LAR is granted, Entergy will only be required to conduct an ILRT once during the period of extended operation, in 2021.

Meanwhile, the IP2 containment is trending towards failing an ILRT by 2016, while the risk posed by seismic events is increasing. Considering that the IP2 containment liner will be over 60 years old by the end of the period of extended operation in 2033, and given the history of degradation experienced by the IP2 containment liner, one ILRT in 27 years of operation (2006 to 2033) represents a wholly inadequate safety margin. Additionally, although Entergy notes that Type B and Type C leakage tests will still be conducted every 60 months, these tests do not measure the overall integrity of the containment liner. See Attachment 1 to NL-14-128, at 6-9.

5 This assumes that the Commission grants the application to renew the IP2s initial 40 year operating license and authorizes the facility to operate for an additional term of up to 20 years; that application is subject to, among other things, a contested proceeding before a NRC Atomic Safety and Licensing Board in which the State has been participating since 2007.

9

By maintaining the existing Technical Specifications for ILRTs, Entergy will be required to test the IP2 containment in 2016, which will assure either that the containment remains within existing acceptance criteria, or that necessary repairs are made to bring the containment into compliance. A second ILRT no later than 2026 will further improve the safety margin, by evaluating whether the IP2 containment meets the applicable acceptance criteria as it nears the end of its (requested) period of extended operation.

9. The LAR also fails to adequately consider the risk that the degraded containment liner and related containment systems and components (including, but not limited to, welds, valves, fittings, vents, filters, circuits, and relays) will fail as a result of seismic activity at IP2. Recent analysis of IP2 reveals that it may be subjected to seismic events of greater intensity more frequently than thought at the time when IP2 received its construction permit in 1966 and its initial 40-year operating license in 1973. The LAR does not address these new seismic data. See to NL-14-182, at 5-26 to 5-31.
10. Entergys justification for reducing the frequency of this important safety-related test is wholly inadequate. Entergy claims that [t]he performance of fewer ILRTs would result in significant savings in radiation exposure to personnel, cost, and critical path time during future refueling outages. Attachment 1 to NL-14-128, at 3. Although minimizing worker exposure to radiation dose is important, reducing the number of required ILRTs - and corresponding worker exposure - to be conducted during the period of extended operation from two to one does not justify exposing millions of State citizens and resources to the risk of radiation escaping from a damaged containment structure. Entergys desire to reduce costs and maximize revenues also does not justify rolling back this important safety-related test. The requirement that Entergy conduct an ILRT every 10 years is part of the IP2 current licensing basis, and is an essential part 10

of NRCs obligation to ensure adequate protection of New York citizens and communities. It is well established that consideration of cost may not enter the NRC decision making when a requirement is part of the adequate protection licensing basis. As the U.S. Court of Appeals for the D.C. Circuit has ruled, [i]n setting or enforcing the standard of adequate protection that

[42 U.S.C. § 2232(a)] requires, the Commission may not consider the economic costs of safety measures. The Commission must determine, regardless of costs, the precautionary measures necessary to provide adequate protection to the public; the Commission then must impose those measures, again regardless of costs, on all holders of or applicants for operating licenses. Union of Concerned Scientists v. Nuclear Regulatory Commission, 824 F.2d 108, 114 (D.C. Cir. 1987).

Finally, the reduction of critical path time - in other words, an increase in plant outage time -

by the few days necessary to conduct an ILRT during refueling outages in 2016 and 2026 does not justify exposing millions of State citizens and the State environment to exposure from radiation escaping from a damaged containment structure.

11. Even assuming cost and increased outage time are relevant considerations in the Commissions consideration of Entergys LAR, Entergy has failed to provide a detailed cost analysis to support its assertion that there would be a considerable saving of time and money if the LAR is granted. Although the outage time and cost may increase if the IP2 containment fails the ILRT in 2016 and repairs are required, Entergy should not object to spending the time and money to make repairs that are necessary to assure the safe operation of IP2.

SUPPORTING EVIDENCE

12. Under 10 C.F.R § 50.92, [i]n determining whether an amendment to a license...

will be issued to the applicant, the Commission will be guided by the considerations which govern the issuance of initial licenses... to the extent applicable and appropriate. Under 11

section 182(a) of the Atomic Energy Act (AEA), 42 U.S.C. § 2232(a), a license application must include sufficient information to show that the issuance of the amendment will provide adequate protection to the health and safety of the public. Under 10 C.F.R. § 50.40(a) and (c),

the Commission, in order to grant a license application, must consider whether: (1) technical specifications... provide reasonable assurance that... the health and safety of the public will not be endangered; and (2) the issuance of the license to the applicant will not, in the opinion of the Commission, be inimical to the common defense and security or to the health and safety of the public.

13. An ILRT, also known as a Type A leakage rate test, is an comprehensive leakage rate test of the containment structure, which measures the integrated leakage rate from all potential leakage paths, including containment liner welds, valves, fittings, and components that penetrate containment. ILRT monitors for any leakage through the containment liner or other structural element due to corrosion or cracking. If a reactors containment liner and associated components, structures, and systems are in good order, a Type A leakage test could be performed in one or two days during a plant outage. If a Type A test identifies a leak, it may be necessary to devote additional time to identify, isolate, and repair the leak. The scope and frequency of Type A, Type B, and Type C leakage rate tests are governed by 10 C.F.R. Appendix J. Notably, the Type B and Type C leakage tests relate to containment penetrations, valves, and other discrete fittings and do not test the overall integrity of the containment liner itself. See to NL-14-128, at 6-9.
14. The history of the IP2 containment liner makes it particularly ill-suited for the reduced safety-margins proposed by Entergy. The IP2 containment structure is a steel-lined reinforced concrete vertical cylinder with a flat base mat and hemispherical dome that 12

completely encloses the entire reactor and reactor coolant system. The containment liner at IP2 is made from several pieces of welded steel, at least 1/4 thick, attached to the inside face of the concrete shell of the containment structure, and is intended to prevent radiation from escaping from IP2 and traveling into Westchester County and the New York City metropolitan area.

15. 1968 Incident. As early as 1968, when the IP2 containment structure was still under construction, plate buckling was detected in the IP2 containment liner in the vicinity of the fuel transfer tube canal penetration. See Report on the Containment Building Liner Plate Buckle in the Vicinity of the Fuel Transfer Canal (January 1968), at 1 (ML093521587). The buckled plates, discovered between elevations 56-7 and 59-7, exceeded the acceptable tolerance limits for local buckling. Id. at 3. The buckling was corrected by forcibly jacking the liner back within tolerance limits and installing strongback and stud anchors to hold the liner within the tolerance limits. Id. at 8. Accordingly, the IP2 containment liner was subjected to unusual stresses from its beginning.
16. 1973 Incident. On November 13, 1973, shortly after IP2 received its operating license, the IP2 containment liner was subject to further damage when the feedwater line to the No. 22 steam generator broke, causing a jet of steam and hot water to deform the containment liner. Letter from William J. Cahill, Jr., Vice-President, Consolidated Edison, to James P.

OReilly, Director, Regulatory Operations of Atomic Energy Commission (Nov. 30, 1973), at 2-3, 5 (ML093560700). Subsequent inspections determined that intermittent bulging extended over an arc of approximately 60 feet at an elevation of 73 in the containment liner. Consolidated Edison Company of New York, Inc., Feedwater Line Incident Report - Indian Point Unit No. 2 (Jan. 14, 1974), at 3-1 to 3-2 (ML100200180). The liner was pulled away from some of the anchor studs holding the liner to the concrete containment shell, and an ultrasonic inspection of 13

the damaged area revealed that 9 of the 18 studs in the bulged area were broken. Id. at 3-2. The ultrasonic inspection also revealed that the studs at this elevation were spaced at intervals of 28 inches, not the specified 14 inches - indeed, the inspection noted the unexplained absence of two rows of studs around the containment circumference. Id. Apparently, even when the containment liner was first installed in IP2, it did not conform with the applicable specifications.

17. Notwithstanding the large swath of damage to the liner resulting from the 1973 feedwater line failure or the mysterious absence of specified studs, the Consolidated Edison Company - the operator of IP2 at the time - told the AEC that the liner could continue to perform its function and that the original acceptance criteria for containment leakage were satisfied. Letter from William J. Cahill, Jr., Vice President, ConEd, to James P. OReilly, Director, Regulatory Operations of Atomic Energy Commission (March 12, 1974)

(ML093560204). The AEC Staff reviewing the incident agreed with ConEds conclusion.

Letter from R.R. Maccary, Assistant Director for Engineering, Licensing, to Donald J. Skovhold, Assistant Director for Operating Reactors, Licensing (April 15, 1974) (ML093630690).

However, AEC Staff recommended that because of this occurrence, increased attention should be given to the surveillance of the liner during the life of the plant and that the frequency of leakage tests required by the technical specification should be increased to a level above the three inspections per ten years then required by the Commissions regulations. Feedwater Line Incident Report (Jan. 14, 1974), attachment to id. at 4 (emphasis added); see 60 Fed. Reg.

49,495, 49,496 (Sept. 26, 1995) (reducing ILRT frequency from three inspections per 10 years to one inspection per 10 years). Despite the warnings from Staff that the frequency of leakage tests should be increased for the IP2 containment liner, the frequency of such tests has been steadily decreased from three per ten years, to once per ten years, and now - if the amendment request by 14

Entergy is granted - to once per fifteen years. See Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request, Revision 0, Attachment 3 to NL-14-128 (October 2013), at 1-1. Furthermore, Entergys request to extend the time between inspections from 10 to 15 years ignores the AEC Staff recommendation for increased attention to the surveillance of the liner during the life of the plant.

18. 1980 Containment Flooding Incident. The IP2 containment liner was subjected to further damage during a 1980 flooding event. An inspection of the containment structure conducted on October 17, 1980 discovered that leaking service water pipes had resulted in the containment area being flooded with more than 100,000 gallons of brackish water from the Hudson River. See NRC, IE Information Notice No. 80-37: Containment Cooler Leaks and Reactor Cavity Flooding at Indian Point Unit 2 (Oct. 25, 1980) (ML031180421). This event resulted in the corrosion of the containment liner at the 46 foot elevation, where it meets the concrete containment floor. See Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178).
19. Revision of Seismic Hazard. Entergy recently provided an updated seismic hazard analysis for IP2. That analysis shows that the anticipated ground motion is larger for higher frequency events than was understood when IP2 received its operating license in 1973. After receiving the Entergy updated analysis, NRC Staff performed its own analysis. The recently-produced ground motion curves appear to be higher than the Safe Shutdown Earthquake (or SSE) design curves that resulted from licensing hearings in the 1970s and were adopted by the Commission. See NRC Staff, Slides, Near-Term Task Force Recommendation 2.1: Entergy, at 6 (June 19, 2014) (ML14169A489).

15

Id. The new revised seismic curves reflect a significantly greater seismic risk for certain systems, structures, and components at IP2 when compared to IP2s original safe shutdown earthquake.

Accordingly, Staff placed IP2 in the Priority Group 1 for additional review. According to Staff, Group 1 plants are generally those that have the highest re-evaluated hazard relative to the original plant seismic design basis as well as ground motions in the 1-10Hz range that are generally higher in absolute magnitude. Group 1 plants are expected to conduct a seismic risk evaluation and submit it by June 30, 2017. NRC Staff, Support Document for Screening and Prioritization Results Regarding Seismic Hazard Re-Evaluations for Operating Reactors in the Central and Easter United Sates, at 2 (May 21, 2014) (ML14136A126).

20. ILRT Results. Published ILRT results indicate that the integrity of the IP2 containment has steadily declined between 1979 and 2006, and is on pace to not meet the applicable acceptance criteria by 2016. The containment leak rate has increased every time the 16

ILRT has been conducted, even as the test pressure (psia) has generally been lowered. to NL-14-128, at 5-6. Indeed, NRC Staff has noted that the historical trend indicates that consistently, for all five historical ILRTs, the As found Leakage is on a continuous trend towards eclipsing the IP2 [Technical Specification] 5.5.14.d.1 leakage rate acceptance criteria of 0.75 La (i.e., 0.075 percent containment weight per day). NRC Staff, Request for Additional Information 4, at 3 (April 28, 2015) (ML15103A259). Table 1 shows the results of the most recent ILRTs.

DATE LEAKAGE RATE

(% Containment Weight per Day)

TEST PRESSURE (PSIA) 1979 August 0.0260 62.7 1984 September 0.0320 65.6 1987 December 0.0342 62.9 1991 June 0.0478 61.7 2006 April 0.0636 60.5 Table 1. Source: Attachment 1 to NL-14-128, at 5-6.

In the 27 years between the 1979 ILRT and the 2006 ILRT, the leakage rate has increased by an average of 0.0014% per year ([0.0636-0.0260]/27). Assuming that leakage rate has not increased since 2006, the expected leakage rate for an ILRT conducted in 2016 would be 0.078 (0.0014*10+0.0636), exceeding the current Technical Specifications leakage rate acceptance criteria of 0.75 La (i.e., 0.075 percent containment weight per day).

21. Recent Inspection History. Recent inspections of the IP2 containment surfaces, including the containment liner, confirm that the liner and related surfaces have been harmed by the historical accidents. An inspection of the liner plate conducted during the 2000 refueling outage revealed (1) coating deterioration and minor corrosion on 40 out of 116 electrical and 17

mechanical penetrations; (2) coating degradation and minor corrosion at elevation 134 ft.; (3) portions of the moisture barrier at the liner basemat interface were deteriorated; (3) liner corrosion between 2 in. above and 3 in. below the concrete containment floor, which had resulted from [the 1980 containment flooding incident] See Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 232 to Facility Operating License No. DPR-26 (Aug. 5, 2002), at 8 (ML021860178). Ultrasonic testing (UT) of the corroded liner plates near the containment floor determined that the liner thickness had deteriorated from.5 inches to.355 inches in one location, which was only.015 inches thicker than the minimum required liner thickness established by the consultant conducting the test. Id. Although NRC Staff determined that the corroded liner nevertheless provided an adequate safety margin at that time -

15 years ago - Entergy has not submitted up-to-date information regarding the current thickness of the liner plate in that area. See Attachment 2 to NL-14-182, at 10-14 (describing various visual inspection results, but no UT testing).

22. In 2008, the visual inspection of containment surfaces, including the containment liner, showed general surface corrosion, minor coating peeling/flaking, blistered paint, loose stainless steel insulation panels and buckling stainless steel insulation panels (VC liner inaccessible) at columns 10 and 11 elevation 68. Attachment 2 to NL-14-128, at 11. Two damaged areas of the stainless steel insulation jacket had to be repaired at this time. Id. at 12. In 2012, inspectors found many of the same conditions, and also observed water seeping adjacent to penetration #69 in the containment building, attributed to repairs that had been conducted in 2000. Id. A 2014 visual inspection confirmed the presence of many of the same conditions, although not the leaking water. Id. Notably, because the last ILRT was performed in 2006, it is 18

unknown whether the wear, leaking water, or loose and buckling panels observed in these visual inspections would result in the failure of an ILRT. See id. at 5.

23. The Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request is based in part on an NRC report on performance based leak testing, NUREG-1493, which analyzed the effects of containment leakage on the health and safety of the public and the benefits realized from containment leak rate testing using a representative PWR plant. Attachment 3 to NL-14-182, at 1-1 to 1-2. That representative plant was the Surry reactor, located in rural Virginia. Id. It is wholly inappropriate to use Surry as a benchmark plant and site for regulatory analysis in a license amendment for IP2, which is located in a densely populated urban and suburban environment and has been subjected to various unique degradation events. See USNRC, Generic Environmental Impact Statement for License Renewal of Nuclear Plants, NUREG-1437, Table 2-1 (1996) (identifying surrounding populations at reactor sites).
24. Deficiencies in the Referenced Severe Accident Analysis. The request to amend the IP2 operating license relies on the 2009 Severe Accident Mitigation Alternatives (SAMA)

Reanalysis, but that analysis omits important considerations and contains erroneous assumptions and inputs.6 Those omissions and errors work to undercount the costs of an offsite radiation release and therefore skew the cost benefit analysis in favor of the requested amendment. By 6 See, e.g., Attachment 3 to NL-14-128, Risk Assessment for Indian Point Regarding the ILRT (Type A) Permanent Extension Request (October 2013) at p. 3-1 (referencing SAMA analysis), 8-1 (reference no. 10 Re-analysis of MACCS2 Models for IPEC, Calculation IP-CALC-09-00265, December 2009); see also, e.g., 8-2 (references n. 20 Appendix E of Applicants Environmental Report for License Renewal Application (April 2007); Attachment 1 to NL-14-128, Analysis of Proposed Technical Specification Changes Regarding 15 Year Containment Test at 16 (referencing License Renewal SAMA analysis). In addition the operating license amendment request references information at p. 3-1 (referencing MACCS2 off-site consequence runs), and 8-1 (reference no. 11 MAAP/MACCS2 Computer Codes Calculated Dose for IPEC Containment Structure Based on Allowable Leakage From an Intact Containment, Calculation IP-CALC-13-00042, September 2013), but this document and associated computer runs are not part of the operating license amendment application. Because this information did not accompany the license amendment request, the State was unable to review and analyze it in preparation for this petition. The State reserves the right to supplement its filings when the information becomes public.

19

way of example, the SAMA analysis does not take into account the value or decontamination cost of offsite properties with iconic value such as landmarks and national monuments, natural resources such as public drinking water reservoirs, or critical regional, state, or national infrastructure. In addition, the analysis artificially and improperly limits its scope to land and population only within 50 miles of the site (distance truncation) and relied on a dollar per person rem value of $2,000, a value which is out of date and should be increased. In support of the petition to intervene and the contentions, the State includes Attachment 1, which identifies some of the unique sites in the New York metropolitan area, and Attachment 2, which depicts the location of reservoirs relative to the Indian Point site.

CONTENTION NYS-2 Entergys Request to Amend the Indian Point Unit 2 Operating License and Technical Specifications Should Be Denied Because Entergy Has Not Submitted an Environmental Report as Required By 10 C.F.R §§ 51.53 and It Has Not Undergone the Required NRC Staff Environmental Review Pursuant to 10 C.F.R § 51.101 and, Despite Entergys Claim to the Contrary, the Proposed Amendment Is Not Categorically Exempt from That Review Under 10 C.F.R. § 51.22(c)(9).

BASES

1. The National Environmental Policy Act (NEPA) and applicable NRC regulations require at least some level of environmental review before the NRC acts on matters potentially affecting the environment. Entergy asserts that its LAR is categorically exempt from environmental review under 10 C.F.R. 51.22(c)(9), because [t]he proposed changes to the IP2

[Technical Specification] do not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation 20

exposure. Attachment 1 to NL-14-182, at 19. This categorical exemption does not apply, because the LAR involves a significant hazards consideration.

2. Contrary to Entergys conclusions, Attachment 1 to NL-14-182, at 17-19, the LAR poses a significant hazard consideration under 10 C.F.R. § 50.92(c), for two reasons:
a. First, the failure to conduct an ILRT of the IP2 containment until 2021 involves a significant increase in the consequence of an accident previously evaluated under 10 C.F.R. § 50.92(c)(1). This is because the ILRT is the only method for testing the overall integrity of the IP2 containment liner. Considering the unique history of the IP2 containment liner and the visual signs of corrosion, wear and degradation observed during recent inspections, it is possible that the integrity of the liner has already been compromised, or will become compromised in the near future. Accordingly, the failure to conduct an ILRT until 2021 increases the consequences of a release of radiation from the reactor, since any such release might escape containment and reach the environment and citizens of the State in amounts that exceed NRC safety standards.
b. Second, the LAR involves a significant reduction in a margin of safety under 10 C.F.R. § 50.92(c)(3). By reducing the frequency of ILRTs, Entergy is necessarily reducing the margin of safety for containment integrity. If the 10-year inspection period were maintained, Entergy would be required to conduct two ILRTs during its 20-year period of extended operation, once in 2016 and a second time in 2026. However, if the LAR is granted, Entergy will only be required to conduct an ILRT once during the period of extended operation, in 2021.

Meanwhile, the IP2 containment is trending towards failing an ILRT by 2016, while the risk posed by seismic events is increasing. Considering that the IP2 containment liner will be over 60 years old by the end of the period of extended operation in 2033, and given the history of degradation experienced by the IP2 containment liner, one ILRT in 27 years of operation (2006 21

to 2033) represents a wholly inadequate safety margin. Additionally, although Entergy notes that Type B and Type C leakage tests will still be conducted every 60 months, these tests do not measure the overall integrity of the containment liner. See Attachment 1 to NL-14-128, at 6-9.

By maintaining the existing Technical Specifications for ILRTs, Entergy will be required to test the IP2 containment in 2016, which will assure either that the containment remains within existing acceptance criteria, or that necessary repairs are made to bring the containment into compliance. A second ILRT no later than 2026 will further improve the safety margin, by evaluating whether the IP2 containment meets the applicable acceptance criteria as it nears the end of its period of extended operation.

3. Because the LAR involves a significant hazards consideration, it does not qualify for the categorical exemptions from environmental review under 10 C.F.R. 51.22(c)(9).

Accordingly, the Commission cannot act on the LAR until an environmental review is complete.

See 10 C.F.R. § 51.101(a)(1).

4. The following bases, offered above in support of Contention NYS-1, are relevant to this contention and are incorporated here by reference: 1-4, and 8.

SUPPORTING EVIDENCE

5. NEPA requires federal agencies to prepare a detailed statement... on the environmental impact of any proposed major federal action significantly affecting the quality of the human environment. 42 U.S.C. § 4332(1)(C)(i). At a minimum, if any agency is going to allow a licensee to engage in activities with environmental impacts without the agency first issuing a detailed environmental impact statement, the agency must do an environmental analysis and issue a finding of no significant impact (FONSI). 40 C.F.R. § 1501.4.

22

6. The NEPA requirements are incorporated into NRC regulations. See 10 C.F.R. Part 51, Subpart A. In general, if a licensing or regulatory action undertaken by NRC is not subject to a categorical exclusion under section 51.22(c) or (d), an environmental impact statement (EIS) under section 51.20(b) or an environmental assessment under section 51.21 is required. Under section 51.101(a), if a proposed licensing or regulatory action requires an environmental impact statement or environmental assessment, the Commission may take [n]o action on the proposal which would (i) have an adverse environmental impact, or (ii) limit the choice of reasonable alternatives until the EIS is complete or a FONSI is made.
7. The following supporting evidence underlying Contention NYS-1, above, is also relevant to this Contention, and is incorporated here by reference: 12-22.

CONCLUSION The States contentions raise a genuine dispute of material law or fact on whether Entergy is entitled to the LAR. Accordingly, the NRC should grant the States Motion for Leave to Intervene and schedule a hearing on the LAR.

Dated: Albany, New York May 18, 2015 Respectfully submitted, Signed (electronically) by John J. Sipos Brian Lusignan Assistant Attorneys General Office of the Attorney General of the State of New York The Capitol Albany, New York 12224 (518) 776-2380 john.sipos@ag.ny.gov brian.lusignan@ag.ny.gov 23

DESIGNATION OF REPRESENTATIVE FOR SERVICE Pursuant to 10 C.F.R. §§ 2.304 (e) and 2.309(h), the State of New York designates the following representative as a person on whom service may be made:

John J. Sipos Assistant Attorney General Office of the Attorney General of the State of New York The Capitol Albany, New York 12224-0341 (518) 776-2380 john.sipos@ag.ny.gov 24

ATTACHMENT 1 List of Historic, Unique or Otherwise Significant Sites within 50 Miles of Indian Point

List of Various Site Specific Improvements, Including Landmarks, Parks, Arenas, Universities, and Transportation Facilities Within 50 Miles of Indian Point Power Reactors and Spent Fuel Facilities National Historic Landmarks:

Brooklyn Bridge Carnegie Hall Central Synagogue Central Park Cooper Union New York Stock Exchange Grand Central Terminal Guggenheim Museum Metropolitan Museum of Art New York Public Library New York Botanical Garden Governors Island New York City Hall Union Square St Patrick's Cathedral Trinity Church Stony Point Battlefield National Parks:

Statue of Liberty National Monument (& Ellis Island)

Saint Paul's Church National Historic Site Appalachian National Scenic Trail General Ulysses S. Grant National Memorial Home of Franklin D.

Roosevelt National Historic Site Vanderbilt Mansion National Historic Site African Burial Ground National Monument Castle Clinton National Monument Governors Island National Monument Federal Hall National Memorial Hamilton Grange National Memorial Gateway National Recreation Area Sagamore Hill National Historic Site Other One World Trade Center Brooklyn Navy Yard Jacob K Javits Convention Center Flushing Meadows-Corona Park Lincoln Center for the Performing Arts Manhattan Municipal Building Outdoor Sports Venues Yankee Stadium Citi Field USTA Billie Jean King National Tennis Center Icahn Stadium Aviator Arena Barclay's Center (under construction)

Hamilton-Metz Field MCU Park Arnold and Marie Schwartz Athletic Center Aqueduct Racetrack Metropolitan Oval Universities United States Military Academy (West Point)

United States Merchant Marine Academy Columbia University New York University Fordham University The Juliard School Culinary Institute of America St. John's University Yeshiva University Brooklyn Law School Brooklyn College CUNY (all campuses)

Vassar College Pace University Pratt Institute Yeshiva University Transportation South Ferry Terminal Howland Hook Marine Terminal Red Hook Container Terminal Brooklyn Marine Terminal New York Passenger Ship Terminal Brooklyn Cruise Terminal Newburgh-Beacon Bridge Bear Mountain Bridge Mid Hudson Bridge Verrazanno Narrows Bridge George Washington Bridge Brooklyn Bridge Manhattan Bridge Williamsburg Bridge Throgs Neck Bridge Robert F. Kennedy Bridge Queensboro Bridge Bronx-Whitestone Bridge Dutchess County Airport Stewart Airport Teterboro Airport Laguardia Airport JFK Airport Westchester County Airport Pennsylvania Station World Trade Center PATH Station Interstate I-95, I-287, I-87 (NYS Thruway),

I-84, NYS Route 9, Taconic Parkway

List of Various Site Specific Improvements, Including Landmarks, Parks, Arenas, Universities, and Transportation Facilities Within 50 Miles of Indian Point Power Reactors and Spent Fuel Facilities New York City Parks:

Randalls Island Park Battery Park Washington Square Park Madison Park Fort Tyron Park The High Line Highbridge Park The Cloisters Bronx Zoo Van Cortlandt Park Prospect Park Bryant Park Jacob Purdy House Fort Wadsworth Jamaica Bay Wildlife Refuge State Parks:

Bayswater Point Clay Pit Ponds East River Empire-Fulton Ferry Gantry Plaza Riverbank Roberto Clemente Clarence Fahnestock Fahnestock Winter Park Franklin D. Roosevelt Hudson Highlands James Baird Mills Norrie (Margaret Lewis Norrie)

Ogden Mills & Ruth Livingston Mills Old Croton Aqueduct Rockefeller Walkway Over the Hudson (Poughkeepsie)

Clinton House John Jay Homestead Philipse Manor Hall Staatsburgh State Historic Site Anthony Wayne Recreation Area Bear Mountain Beaver Pond Campgrounds Blauvelt Goosepond Mountain Harriman High Tor Highland Lakes Lake Sebago Beach Lake Tiorati Beach Lake Welch Beach Minnewaska Preserve Nyack Beach Rockland Lake Schunnemunk Silver Mine Sterling Forest Storm King Tallman Mountain Fort Montgomery Knox's Headquarters National Purple Heart Hall of Honor New Windsor Cantonment Stony Point Battlefield Washington's Headquarters Bethpage Golf Course Caumsett Planting Fields Arboretum Walt Whitman Birthplace Prepared by Adam Solomon

ATTACHMENT 2 Map of Reservoirs in Vicinity of Indian Point

DISTANCE TO NEW YORK RESERVOIRS FROM INDIAN POINT NUCLEAR FACILITIES

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION


x In the Matter of:

Docket No. 50-247-LA License Amendment Request of Entergy Nuclear License No. DPR-26 Operations, Inc. dated December 9, 2014, for Indian Point Nuclear Generating Unit No. 2 to Postpone Testing of Containment Integrity May 18, 2015


x CERTIFICATE OF SERVICE I hereby certify that on May 18, 2015, copies of the State of New Yorks Petition to Intervene and Request for Hearing were served electronically via the Electronic Information Exchange on the following recipients:

E. Roy Hawkens Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Mailstop 3 F23 Two White Flint North 11545 Rockville Pike Roy.Hawkens@nrc.gov Office of Commission Appellate Adjudication U.S. Nuclear Regulatory Commission Mailstop 16 G4 One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 ocaamail@nrc.gov Office of the Secretary Attn: Rulemaking and Adjudications Staff U.S. Nuclear Regulatory Commission Mailstop 3 F23 Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 hearingdocket@nrc.gov Clara.Sola@nrc.gov Sherwin E. Turk, Esq.

David E. Roth, Esq.

Beth N. Mizuno, Esq.

Brian G. Harris, Esq.

Anita Ghosh, Esq.

Edward Williamson, Esq.

John Tibbets Office of the General Counsel U.S. Nuclear Regulatory Commission Mailstop 15 D21 One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 sherwin.turk@nrc.gov david.roth@nrc.gov beth.mizuno@nrc.gov brian.harris@nrc.gov anita.ghosh@nrc.gov Edward.Williamson@nrc.gov John.Tibbets@nrc.gov Jeanne Cho Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Jcho1@entergy.com 1

Paul M. Bessette, Esq.

Raphael Kuyler, Esq.

Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 pbessette@morganlewis.com rkuyler@morganlewis.com John Sipos, Esq.

Lisa Kwong, Esq.

Brian Lusignan, Esq.

Office of the Attorney General of the State of New York The Capitol Albany NY 12224 John.Sipos@ag.ny.gov Lisa.Kwong@ag.ny.gov Brian.Lusignan@ag.ny.gov Signed (electronically) by Brian Lusignan Assistant Attorney General State of New York (518) 776-2399 Brian.Lusignan@ag.ny.gov Dated at Albany, New York This 18th day of May, 2015 2