UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Vice President, Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 April 28, 2015

SUBJECT:

INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE PROPOSED LICENSE AMENDMENT TO PERMANENTLY EXTEND THE CONTAINMENT TYPE A LEAK RATE TEST FREQUENCY TO 15 YEARS (TAC NO. MF5382)

Dear Sir or Madam:

By letter dated December 9, 2014, Entergy Nuclear Operations, Inc., submitted a license amendment request that would revise Technical Specification 5.5.14 for Indian Point Nuclear Generating Unit No. 2 in order to change the frequency of the Type A, or the containment integrated leak rate test, from once every 10 years to once every 15 years on a permanent basis.

The U.S. Nuclear Regulatory Commission staff has reviewed the submittal and determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). Based on our discussions, we understand that a response to the RAI will be provided within 30 days of the date of this letter.

If you have any questions, please contact me at (301) 415-1364 or Douglas.Pickett@nrc.gov.

Docket No. 50-247

Enclosure:

Request for Additional Information cc w/enclosure: Distribution via Listserv Sincerely, Douglas V. Pickett, Senior Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

REQUEST FOR ADDITIONAL INFORMATION PERMANENT EXTENSION OF THE TYPE A LEAK RATE TEST TO 15 YEARS ENTERGY NUCLEAR OPERATIONS. INC.

INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 DOCKET NO. 50-247 CONTAINMENT AND VENTILATION BRANCH (SCVB)

SCVB RAl-1 License Amendment Request (LAR) Section 4.3.1, "ILRT [Integrated Leak Rate Test] Results" (Attachment 1, pages 5 and 6 of 19 (Reference 1 )), details all test pressures in the absolute pressure scale of "psia" [pounds per square inch absolute]. Without providing the corresponding atmospheric pressure for each test pressure, the U.S. Nuclear Regulatory Commission (NRC) staff cannot confirm that the "calculated peak containment internal pressure for the design basis loss of coolant accident, Pa.... "of 47 psig [pounds per square inch gauge]

was satisfied during ILRT performance (Reference Indian Point Nuclear Generating Unit No. 2 (IP2) Technical Specification (TS) 5.5.14.b), consistent with the direction of Nuclear Energy Institute (NEI) 94-01, Revision 2-A (Reference 2) and the test methodology of American National Standards Institute/American Nuclear Society (ANSI/ANS) 56.8-2002 (Reference 3).

For example, an excerpt from Section 4.3.1 reads:

The last two tests were:

1. The last ILRT in April 2006 had a measured containment leak rate (Um) at the test pressure of 60.5 psia was 0.0636% containment air weight/day with a 95% confidence level.

Since Pa equals 47 psig, a test pressure of 60.5 psia prompts concern that the test pressure was not greater than Pa*

The NRC staff requests that the licensee provide the corresponding recorded atmospheric pressures from each of the five ILRT results recorded in Section 4.3.1.

SCVB RAl-2 The last sentence of Attachment 1, page 6 of 19 (Reference 1) from LAR Section 4.3.2, "Type B and C testing," reads, "Notes are provided for test failures." However, no notes in Table 4.3-2 or subsequent pages of the LAR were provided that detail (a) which Type B and Type C local leak rate tests (LLRTs) failed, (b) what corrective actions were performed, and (c) what historical test Enclosure failures have been repetitive from the total population of Type B penetrations and Type C isolation valves.

The NRC staff requests that the licensee provide this missing information.

SCVB RAl-3 The NRC staff notes that the use of NEI 94-01, Revision 2-A (Reference 2) is acceptable for referencing by licensees proposing to amend their TSs to permanently extend the ILRT surveillance interval to 15 years, provided six specific conditions are satisfied.

Condition 1 from Section 4.1 of NEI 94-01, Revision 2-A reads:

For calculating the Type A leakage rate, the licensee should use the definition in the NEI TR 94-01, Revision 2, in lieu of that in ANSl/ANS-56.8-2002. (Refer to SE [Safety Evaluation] Section 3.1.1.1.).

Section 5.0 of the SE for NEI 94-01, Revision 2-A, reads:

The performance leakage rate is calculated as the sum of the Type A upper confidence limit (UCL) and as-left minimum pathway leakage rate (MNPLR) leakage rate for all Type B and Type C pathways that were in service, isolated, or not lined up in their test position (i.e., drained and vented to containment atmosphere) prior to performing the Type A test. In addition, leakage pathways that were isolated during performance of the test because of excessive leakage must be factored into the performance determination. The performance criterion for Type A tests is a performance leak rate of less than 1.0 La.

Section 3.2.9, "Type A test performance criterion," of ANSl/ANS-56.8-2002 (Reference 3) defines the "performance leakage rate" and reads, in part:

The performance criterion for a Type A test is met if the performance leakage rate is less than La. The performance leakage rate is equal to the sum of the measured Type A test UCL and the total as-left MNPLR of all Type B or Type C pathways isolated during performance of the Type A test., page 4 of 19 of Entergy's LAR (Reference 1) for I P2 compliance with Condition 1 reads:

Implementation of NEI 94-01 Rev 2A will require use of the definition of "performance leakage rate" defined in Section 5.0 for calculating the Type A leakage rate when performing Type A tests.

The NRC staff notes that the "As found Leakage" is on a continuous trend towards eclipsing the IP2 TS 5.5.14.d.1 leakage rate acceptance criteria of less than or equal to (:s;) 0.75 La (i.e., 0.075 percent containment weight per day) as reflected in SCVB RAl-4 (below). The staff needs to develop a better understanding of why this phenomenon is occurring to make its regulatory decision. The staff notes that IP2's statement of compliance indicates future tense (i.e., "will require"). To make its regulatory decision, the staff needs to understand whether IP2's Type A ILRT plant test procedures currently reflect the NEI 94-01, Revision 2-A definition of "performance leakage rate." If the IRL T test procedures currently reflect the requisite definition, the staff requests historical information as to when the requisite NEI 94-01, Revision 2-A, definition was adopted into IRL T test procedures. In addition, the staff requests that Entergy Nuclear Operations, Inc. (Entergy), provide a copy of the current IP2 IRL T test procedures, plant drawings, etc. (or procedural excerpts from these documents), to aid the staff in understanding why this phenomenon is occurring, SCVB RAl-4 LAR Section 4.3.1, "ILRT Test Results" (Attachment 1, pages 5 and 6 of 19 (Reference 1))

summarizes the IP2 Type A ILRT test results since August 1979. These test results are summarized in the following table:

Date As found Leakage Test Pressure (psia)

(Percent Containment weight per day)

April 2006 0.0636 60.5 June 1991 0.0478 61.7 December 1987 0.0342 62.9 September 1984 0.0320 65.6 August 1979 0.0260 62.7 The NRC staff notes that the historical trend indicates that consistently, for all five historical ILRTs, the "As found Leakage" is on a continuous trend towards eclipsing the IP2 TS 5.5.14.d.1 leakage rate acceptance criteria of s 0.75 La (i.e., 0.075 percent containment weight per day).

Given the above ILRT results trend, the NRC staff requests that:

(1) The licensee explain why this phenomenon is occurring at IP2. More importantly, what is IP2's long-term corrective action plan to arrest or reverse this trend?

(2) Entergy should include in its response a discussion of any IP2 containment modifications (major or minor) that may have affected containment integrity since August 1979.

(3) For each ILRT, the licensee provide the individual cumulative MNPLR leakage rate for all Type B and Type C pathway test values that constitute a part of the total performance leakage rate (i.e., "As found Leakage") values identified in the table above.

(4) Additional information about how IP2 plant programs satisfy the guidance of Regulatory Position 3, "Element 3: Define Implementation and Monitoring Program," of Regulatory Guide (RG) 1.17 4, Revision 2 (Reference 4 ).

REFERENCES:

1. Letter NL-14-128, dated December 9, 2014, from Lawrence Coyle, Entergy Nuclear Operations to U.S. Nuclear Regulatory Commission regarding the Proposed License Amendment Regarding Extending the Containment Type A Leak Rate Testing Frequency to 15 Years (Agencywide Documents Access and Management System (ADAMS) Accession No. ML14353A015).
2. NEI 94-01, Revision 2-A, "Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J," October 2008 (ADAMS Acces.sion No. ML100620847).
3. ANSl/ANS-56.8-2002, Reaffirmed August 9, 2011, "Containment System Leakage Testing Requirements."
4. RG 1.174, Revision 2, dated May, 2011, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis" (ADAMS Accession No. ML100910006).

ML15103A259 OFFICE LPL 1-1/PM LPL 1-1/PM LPL2-2/LAiT NAME AGilbertson DPickett LRonewicz DATE 4/13/2015 4/24/2015 4/20/2015 RidsNrrPMlndianPoint RidsACRS_MailCTR LPL2-2/LA SC VB/BC KGoldstein RDennig by (BClayton for) email dated 4/21/2015 3/30/2015