CD 6

H Pacific Gas and Electric Company Diablo Canyon Power Plant NPDES RECEIVING WATER MONITORING PROGRAM: 2014 ANNUAL REPORT April 21, 2015 Submitted to:

Pacific Gas and Electric Company Diablo Canyon Power Plant Avila Beach, CA 93424 Prepared by:

0 TENRAEnvironmental 141 Suburban Rd., Suite A2 San Luis Obispo, CA 93401

Table of Contents Table of Contents

1.0 INTRODUCTION

1 2.0 TEMPERATURE MONITORING........................................................................ 4 3.0 INTERTIDAL ALGAE AND INVERTEBRATES........................................................1l0 4.0 INTERTIDAL FISHES.................................................................................. 12 5.0 SUBTIDAL ALGAE AND INVERTEBRATES.......................................................... 13 6.0 SURFACE CANOPY KELPS........................................................................... 15 7.0 SUBTIDAL FISHES..................................................................................... 16 8.0 RWMP PROJECT PERSONNEL...................................................................... 18 9.0 LITERATURE CITED.................................................................................. 19 APPENDIX A. Intertidal Temperatures APPENDIX B. Subtidal Temperatures APPENDIX C. Intertidal Algae, Invertebrates and Substrates APPENDIX D. Intertidal Fishes APPENDIX E. Subtidal Algae and Invertebrates APPENDIX F. Subtidal Algae APPENDIX G. Subtidal Invertebrates APPENDIX H. Subtidal Fishes O

ESLO201 5-005 PG&E,, DCPP-RWMP 2014 Annual Report

Table of Contents List of Tables Table 1. Tasks, stations, and frequency of surveys for the DCPP RWMP, 2014............................. 2 List of Figures Figure 1. Location of the Diablo Canyon Power Plant......................................................... 3 Figure 2. Locations of intertidal temperature monitoring stations............................................. 7 Figure 3. Locations of subtidal temperature monitoring stations............................................... 7 Figure 4. Seawater temperatures in 2014 recorded in control areas, south Diablo Cove, north Diablo Cove, and Field's Cove for: a) intertidal; and b) subtidal. Mean, maximum, and minimum temperatures are shown by month for each area........................................................... 8 Figure 5. DCPP 2014 average daily intake and discharge seawater temperatures (0C) and the daily cooling water discharge volume (MGD)................................................................... 9 Figure 6. Locations of horizontal band transect stations....................................................... 10 Figure 7. Locations of vertical band transect stations......................................................... 12 Figure 8. Locations of subtidal benthic stations................................................................ 14 Figure 9. Map of surface kelp in Diablo Cove on October 6, 2014.......................................... 15 Figure 10. Locations of subtidal fish observation transects................................................... 16 O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report i

1.0 Introduction 1.0 Introduction Monitoring of the marine environment near the Diablo Canyon Power Plant (DCPP) is required by WDR Order No. 90-09 (National Pollutant Discharge Elimination System (NPDES) Permit No. CA0003751I), as revised in a letter from the Central Coast Regional Water Quality Control Board in December 1998. Changes in the marine environment in the vicinity of DCPP (Figure 1) are monitored by the Receiving Water Monitoring Program (RWMP) in accordance with the NPDES Permit.

This report presents seawater temperature and biological data collected in 2014 from the program's intertidal and subtidal monitoring tasks (Table 1). The sampling methods for each task are described, and the 2014 results are presented in the report's appendices.

The biological monitoring tasks were completed at fixed stations in areas that experience increased seawater temperatures from the DCPP thermal discharge, and in areas outside the influence of the discharge (Table 1). With the exception of the habitat-forming kelp survey task, the sampling frequency for the tasks was four surveys per year. A survey consisted of sampling several locations (stations) over a period of time, which varied depending on logistics, staffing resources, weather, sea state, and tide conditions. The survey date listed in the appendix tables for any particular task represents the mean date for the time period that each station was sampled for that survey. All monitoring tasks and surveys were completed in 2014 except for the fourth quarter fish surveys, which were completed in January 2015.

This report does not include analysis or discussion of the results of the biological or temperature monitoring. Comprehensive analyses of changes in the marine environment resulting from the DCPP discharge have been presented in Tenera (1988, 1997, 1999a, 1999b, 2002).

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual ReportI

1.0 Introduction Table 1. Tasks, stations, and frequency of surveys for the DCPP RWMP, 2014. (See text for sampling method descriptions and station locations).

Temperature Monitoring NC 2, FC 1, FC 2, FC 3, NDC 1, NDC 2, NDC 3, SDC 1, SOC 2, SDC 3, Intertidal (recorded every' 20 mai)

SOP 1, SOP 2, SC 1, and SC 1V NC 1 -3m, FC 1 -3m, NDC 2 -3m, NDC 3 -3m, NDC 4 -4m, SOC 1 -3m, Subtidal (recorded every' 20 min)

SDC 4 -Am, SC 1 -3m, and SC 2 -6m Intertidal Horizontal Band Transects (algae, seagrasses, invertebrates, substrate)

NC 1, NC 2, FC 1, FC 2, FC 3, NDC 1, NOC 2, NOC 3, SOC 1, 4 surveys per year SOC 2, SOC 3, SOP 1, SOP 2, and SC 1 Intertidal Vertical Band Transects (fishes) 4 surveys per year NC 1V, FC lV, NDC 1V, SOC 2V, and SC 1V Subtidal Benthic Stations (algae, invertebrates, substrate)

FC 1 -3m, NOC 2 -3m, NDC 3 -3m, NDC 4A-m, SOC 2 -3m, SOC 3A-m, 4 surveys per year SC 1 -3m, and SC 2 -6m Subtidal Fish Observations (fishes)

FC FO-1, FC FO-2, FC FQ-3, NDC EQ-i, NDC FO-2, NOC FO-3, SOC EQ-i, 4 surveys per year SOC FO-2, SOC FO-3; SC EQ-i, SC FQ-2, and SC FO-3 Habitat-Forming Kelp Survey (bull kelp, giant kelp) 1 survey per year Diablo Cove SESLQ201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 2

1.0 Introduction Figure 1. Location of the Diablo Canyon Power Plant.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 3

2.0 Temperature Monitoring 2.0 Temperature Monitoring Intertidal and subtidal seawater temperatures were recorded at permanent stations located along the Diablo Canyon coastline. Temperature units at intertidal stations were located along the rocky shore at the +0.6 m (+2.0 ft) mean lower low water (MLLW) elevation (Figure 2).

Subtidal temperature recorders were located at depths from -3 m to -6 m (-10 ft to -20 ft) MLLW (Figure 3). The designations for individual stations reflects the area location and station number, and, for subtidal stations, includes the station's depth relative to MLLW (e.g., NDC 1 -3 m is north Diablo Cove subtidal Station 1 at a depth of -3 m (-10 ft) MLLW).

There were 13 stations in Diablo Cove regularly contacted by the discharge plume:

Intertidal: NDC 1, NDC 2, NDC 3, SDC 1, SDC 2, SDC 3, SDP 1, and SDP 2.

Subtidal: NDC 2 -3m, NDC 3 -3m, NDC 4 -4m, SDC 1 -3m, and SDC 4 -4m.

There were four stations in Field's Cove, approximately one kilometer upcoast from Diablo Cove, contacted intermittently by the discharge plume:

Intertidal: FC 1, FC 2, and FC 3.

Subtidal: FC 1 -3m.

There were six control stations beyond the influence of the discharge, which measured ambient ocean temperatures:

Intertidal: NC 2, SC 1, and SC lV.

Subtidal: NC 1 -3m, SC 1 -3m, and SC 2 -6m.

The intertidal stations in South Control and Stillwater Cove both use the same acronym, but are located in different locations as shown in Figure 3.

Each instrument synchronously logged temperatures every 20 minutes throughout its deployment period. Instrument precision was 0.025°C with an accuracy of +/- 0.05°C. Temperature units were deployed at a station for approximately 60-90 days and then exchanged with a serviced, calibrated unit. Intertidal temperature units recorded water temperatures only when tide levels were higher than about +0.6 m (+2.0 it) MLLW. Air temperatures were removed from the database by matching the temperature records with the times that the tide level dropped below

+0.6 m (+2.0 ft) MLLW, using a tidal height database derived from NOAA tide gauges at Morro Bay and Port San Luis.

Seawater temperatures recorded at the intertidal and subtidal temperature monitoring stations in 2014 are presented in Appendix A and Appendix B, respectively. Below is a summary of seawater temperatures recorded in the year, based on data from a subset of the temperature recording stations in the control areas, north Diablo Cove, south Diablo Cove, and Field's Cove.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 4

2.0 Temperature Monitoring Intertidal monthly mean, maximum, and minimum temperatures recorded in 2014 at the +0.6 m

(+2.0 fi) (MLLW) elevation at stations in Stillwater Cove (SC 1V), south Diablo Cove (SDC 2),

north Diablo Cove (NDC 2), and Field's Cove (FC 2) are shown in Figure 4a. Data from the other two intertidal control areas were not used in the analysis because more than two months of data were missing due to instrument failure from stations NC 2 and SC 1 (Appendices A1 and A6, respectively). Monthly mean ambient seawater temperatures at the Stillwater Cove control station ranged from a low of 12.5°C (54.4°F) in April to a high of 17.1°C (62.7°F) in July.

Intertidal seawater temperatures are usually warmest at the Diablo Cove stations in late summer to early fall. However, in 2014 the warm water period extended from July through December.

Compared to the control station, intertidal seawater temperatures averaged 2.9°C (5.2°F) warmer in south Diablo Cove and 2.8°C (5.1°F) warmer in north Diablo Cove. Intertidal seawater temperatures at the Field's Cove station were 0.2°C (0.3°F) warmer than the control station, on average.

Subtidal monthly mean, maximum, and minimum temperatures recorded in 2014 at -3 m MLLW in South Control (SC 1 -3m), south Diablo Cove (SDC 1 -3m), north Diablo Cove (NDC 2 -3m),

and Field's Cove (FC 1 -3m) are shown in Figure 4b. Monthly mean ambient seawater temperatures at the South Control station ranged from a low of 11.3°C (52.3°F) in April to a high of 16.4°C (61.5°F) in October. Subtidal temperatures are usually warmest at the Diablo Cove stations in summer to early fall. However, in 2014 the warm water period extended from July through December. Compared to the control station, subtidal temperatures averaged 2.5°C (4.4°F) warmer in south Diablo Cove and 3.8°C (6.80 F) warmer in north Diablo Cove. Subtidal temperatures at the Field's Cove station were 0.9°C (1.6°F) warmer than the control station on average.

DCPP typically operates at full capacity, but there were several periods in 2014 when one or two of the four main circulating water pumps (CWP) were not in service due to scheduled and unscheduled outages or curtailments. This resulted in lower volumes of heated seawater flowing into Diablo Cove. The effects of these seven outages or curtailments can be seen in Figure 5:

  • January 10 - 14, 2014: Unit 2 maintenance outage and curtailment to clean biofouling from the circulating water tunnels. One CWP removed from service.
  • February 2 - 5, 2014: Unit 2 forced outage due to Main Bank Transformer flashover during rain storm. One CWP removed from service.
  • February 9, 2014 -

March 12, 2014: Unit I refueling outage (1R18). Two CWPs removed from service.

  • March 17 - 24, 2014: Unit I forced outage to replace reactor coolant pump (RCP) seal. One CWP removed from service.
  • August 18 - 21, 2014: Unit 2 forced outage. One CWP removed from service.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 5

2.0 Temperature Monitoring

  • October 5, 2014 - November 9, 2014: Unit 2 refueling outage (2R18). Two CWPs removed from service.
  • December 4 - 8, 2014: Unit 1 maintenance outage and curtailment to clean biofouling from the circulating water tunnels. One CWP removed from service.

In addition to those activities that reduced the volume of heated seawater discharged by DCPP, there were also maintenance outages and curtailments that reduced the amount of power being generated without necessitating any reduction in cooling water flow. These activities reduced the temperature of the discharge water without a corresponding decrease in the ambient seawater / intake temperature. Examples of these discharge temperature reductions can be seen in Figure 5 on March 1, May 31, June 8, August 14, September 6, and December 31.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report6

2.0 Temperature Monitoring Lion Rock Figure 2. Locations of intertidal temperature monitoring stations.

Lion Rock Figure 3. Locations of subtidal temperature monitoring stations.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 7

2.0 Temperature Monitoring a) Intertidal Temperatures 25.0 1 0

a..

a.E 21.0 17.0 77.0 69.8

-l 62.6 *.

55.4 48.2 13.0 9.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2014 U Control

    • South Diablo Cove b) Subtidal Temperatures o North Diablo Cove U Field's Cove 25.0 3.=

0 I.-

E 21.0 17.0 77.0 69.8

-I 62.6 *.

'11 55.4 48.2 13.0 9.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2014 Figure 4. Seawater temperatures in 2014 recorded in control areas, south Diablo Cove, north Diablo Cove, and Field's Cove for: a) intertidal; and b) subtidal. Mean, maximum, and minimum temperatures are shown by month for each area. (See text for temperature recording stations used in this figure).

SESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 8

2.0 Temperature Monitoring 30 3000 25

!*2500 U.

2" 0 2000 0

0.
2.

E a

e a

~

a u

u u

e c

o e

2014 Figure 5. DCPP 2014 average daily intake and discharge seawater temperatures cooling water discharge volume (MGD).

(0C) and the daily O

ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 9

3.0 Intertidal Algae and Invertebrates 3.0 Intertidal Algae and Invertebrates Intertidal algae, seagrasses, and invertebrates were sampled using the horizontal band transect (HBT) sampling method at the locations shown in Figure 6. Most HBT stations consisted of two 30 m long transects oriented parallel to the waterline, one at the +0.9 m (+3 ft) MLLW tide level and the other at the +0.3 m (+1 ft) MLLW tide level. Stations SDP I and SDP 2 each consisted of one transect at the +0.9 m (+3 fi) tide level. The substrate at the +0.9 m (+3 ft) MLLW level at Station SDC 1 was mainly uncolonized cobble. Therefore, the upper transect at that station was located at a lower elevation at the +/-0.6 m (+2 fi) MLLW tide level on bedrock where intertidal species were more abundant. The sampling area of each transect consisted often 1.0 m2 (10.8 It2) permanent quadrats. The quadrats were mainly located on bedrock and boulders, but various amounts of cobble and sand that occurred seasonally were also sampled. Three control stations were located beyond the range of thermal discharges from DCPP, while the remaining 11 stations in Field's Cove, Diablo Cove, and on South Diablo Point (south headland of Diablo Cove) received varying levels of contact with warm water from the discharge.

Coven RRockk:h Diablo Rodck*

Diablo Figuzotl an r

e6Loainofhrznabadtansect stations.***I The sampling was conducted by taking visual estimates of percent cover for all algal species, seagrasses, and bare substrate. Coverage estimates were first done for overstory species and then the overstory branches and blades were moved aside to allow estimation of the percent cover of the understory species and bare substrates. Species that occupied less than 0.7% of the area of the O

ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 10

3.0 Intertidal Algae and Invertebrates quadrat were recorded as "present." Due to the overlapping layers of multiple algal taxa, the total algal cover plus bare substrate cover almost always exceeded 100 percent in a quadrat.

Intertidal invertebrates were sampled concurrently in the same quadrats as the algae. In five of the ten quadrats, all species were recorded as either present or absent, except individuals that were larger than 2.5 cm (1 in.) in greatest dimension were counted. In the remaining five quadrats ("count quadrats"), the same method was used except that select species of invertebrates were counted regardless of size. The percent cover of sessile invertebrates, such as sponges and tunicates, was estimated using the same methods used for the algae. All invertebrates, algae, and seagrasses were identified to the lowest taxonomic level practical. All black abalone, regardless of size, were counted in the ten permanent quadrats and in five additional quadrats on each transect.

The survey mean and standard deviation, and annual mean abundance for each taxon at each transect level are presented in Appendix C. Survey statistics for algae and substrates were calculated from all ten quadrats along the transect, while statistics for the invertebrates were calculated from the five "count" quadrats. If a taxon was only recorded as present in a quadrat, its abundance was given a value of 0.000001 for calculating summary statistics.

O ESLO201 5-00 5 PG&E

  • DCPP-RWMP 2014 Annual Report 11

4.0 Intertidal Fishes 4.0 Intertidal Fishes Intertidal fishes were sampled using the Vertical Band Transect (VBT) sampling method. At each of five stations (Figure 7), three transects were positioned perpendicular to the shoreline at fixed locations. Each transect originated in the high intertidal zone (approximately + 1.5 m

[4.9 ft] MLLW) and terminated in the low intertidal zone (approximately -0.2 m [0.6 ft]

MLLW). Transects at each station were separated by approximately 3 m (9.8 ft). Each transect was used as a reference line to position twelve 1.0 m2 (10.8 ft2) permanent sampling quadrats, for a total of thirty-six 1.0 m2 (10.8 ft2) quadrats per station. Two control stations were located beyond the range of thermal discharges from DCPP, while the remaining three stations in Field's Cove and Diablo Cove received varying amounts of warm water influence from the discharge.

In sampling, moveable rocks were carefully lifted and any fishes seen were captured in small hand nets. Foliose algae were also searched for cryptic fishes. Fishes were identified to the lowest practical taxonomic level, measured, and returned to the quadrat following sampling.

Newly settled juvenile fishes were not identified to the species level but were grouped into composite taxa (e.g., Pholididae/Stichaeidae, Anoplarchus/Cebidichthys).

The total numbers observed at each station during the four surveys of the year, and annual mean abundance and standard deviation of fishes for each taxon are presented in Appendix D).

North Control

/

NCIV ben Rock Field'.,

Cove Diablo RockN.

Diablcov Cove Poet San Luis\\

SDC 2V Intake Cove sout control Figure 7. Locations of vertical band transect stations.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 12

5.0 Subtidal Algae and Invertebrates 5.0 Subtidal Algae and Invertebrates Eight permanent subtidal benthic sampling stations located in depths ranging from -3 m to -6 m

(-10 ft to -20 ft) MLLW were sampled during the year (Figure 8). Two control stations were located in Patton Cove, beyond the range of thermal discharges from DCPP, while the remaining six stations received varying amounts of warm water influence from the discharge. Stations were circular with a radius of 3.15 m (10.33 ft), and a sampling area of 28.0 m2 (301.4 ft2). The center 3.1 m2 (33.4 ft2) of each station, which surrounded a mooring anchor (railcar wheel), was not sampled in order to avoid any unnatural algal and invertebrate growth associated with the mooring. Each station was divided into four equal sections, or "arc quadrants," 7.0 m2 (75.3 ft2) in area. All stations were established primarily on substrates of mixed bedrock and boulders with small amounts of cobble and sand.

Divers used three sampling methods at each station to sample the benthic algae and invertebrates. In the first method, individual species of kelp (brown algae of the order Laminariales and Fucales) and macroinvertebrates were counted in each subtidal arc quadrant (SAQ sampling method). Kelp plants and individuals of select invertebrate taxa were counted regardless of their size. Individuals of other non-encrusting invertebrates were counted if they were larger than 2.5 cm (1.0 in.) (length or width). Juvenile kelp plants that could not be identified to the species level were counted and recorded as "Laminariales." Five common species that generally occurred in numbers too high to accurately count in a large area were sampled in the same one-third area (2.33 m2 [25.1 ft2I) of each quadrant, each survey. The count for each of these species was multiplied by three to provide an abundance estimate for the entire quadrant.

In the second sampling method, subtidal line contact, (or SLC) all understory algal species were quantified at the stations as percent cover using a series of pre-selected random points. A radius line with ten lead markers positioned at decreasing intervals toward the station perimeter was attached to the center of the station and used to locate sampling loci in each quadrant. Fifty random contact points were sampled within each quadrant (total of 200 points per station), and the same pre-selected set of points was used at all stations. Random sampling points were changed for each survey. The presence of all algal species, sessile invertebrates, and substrates observed directly under or over the points was recorded. Holdfasts of kelp species were also included when contacted by the sample points. The percent cover of each species and substrate type was calculated by dividing the number of "contacts" by the number of points sampled. All algal species on the station were identified to the lowest taxonomic level practical. In each quadrant, algal species that were present but not contacted by the sample points were noted separately as being 'present' in the quadrant.

In the third method, invertebrates were sampled using the subtidal fixed quadrat (SFQ) method in four permanent circular 0.25 m2 (2.7 ft2) quadrats at each station. The method quantified species composition and abundance of all invertebrate taxa visible to the naked eye. One O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 13

5.0 Subtidal Algae and Invertebrates permanent quadrat was located within each of the four SAQ quadrants, generally on bedrock or boulder substrate. Depending upon the degree of topographical relief, two quadrats were located on horizontal-aspect surfaces and two quadrats were located on vertical-aspect surfaces. All non-encrusting taxa were identified and counted. The coverage of encrusting taxa (e.g.,

colonial/social tunicates) was quantified in square inch units if the total equaled, or exceeded 6.5 cm 2 (1 square inch). Otherwise, the encrusting taxon was recorded as "present."

The survey mean and standard deviation for each taxon at each station from the four surveys completed during the year are presented in Appendices E (SAQ), F (SLC), and G (SFQ). The means are based on the data from the four quadrats or quadrants at each station. The tables also list annual mean taxa abundances by station based on the average of all surveys sampled over the year. Algal taxa in the SLC study, and encrusting taxa in the SFQ study, that were recorded as only present (no numeric value) were given a value of 0.000001 for calculating abundance statistics.

Not Ioto Lion Rock Field's Cove FC 1-3m Diablo Rock*

Diablo o Cove Poult San Luis\\

Intake Cove' South Control /

Figure 8. Locations of subtidal benthic stations.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 14

6.0 Surface Canopy Kelps 6.0 Surface Canopy Keips The locations and extent of the surface kelp canopies of Nereocystis luetkeana (bull kelp) and Macrocystis pyrifera (giant kelp) in Diablo Cove within and outside the fixed benthic stations were mapped from direct observations. This task has been completed annually since the 1 970s to document long-term changes in the annual maximum extent of the surface kelp canopies in Diablo Cove. Near the end of the annual growth cycle in October, nearly all bull kelp plants have reached the surface and can be counted. Surface canopies of giant kelp also tend to be abundant during this period. Two observers at the headland of north Diablo Cove and two observers at the headland of south Diablo Cove (south Diablo Point) counted and mapped the distribution of individual bull kelp plants and mapped the spatial extent of giant kelp canopies (Figure 9). Bull kelp plants with bare bulbs only and no attached fronds, indicating senescence in the plants, were noted when observed.

The annual habitat-forming kelp survey was conducted on October 6, 2014. No bull kelp plants were observed in Diablo Cove during the survey; giant kelp canopies occurred in both north and south Diablo Cove (Figure 9). There are no appendix figures or data tables associated with this task.

r Figure 9. Map of surface kelp in Diablo Cove on October 6, 2014.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 15

7.0 Subtidal Fishes 7.0 Subtidal Fishes Visual counts of fishes were conducted by divers at 12 permanent subtidal stations (three stations in each of four areas) located within and outside of Diablo Cove (Figure 10). Three control stations located in Patton Cove were beyond the range of thermal discharges from DCPP, while the remaining nine stations in Field's Cove, north Diablo Cove, and south Diablo Cove received varying amounts of warm water influence from the discharge.

Each station consisted of a benthic transect 50 m (164 ft) long by 4 m (13 fi) wide by 1 m (3.3 ft) above the bottom, and a 50 m (164 ft) long by 4 m (164 ft) diameter midwater transect located above and parallel to the benthic transect approximately midway between the surface and the bottom. A station was sampled by first deploying a fiberglass measuring tape to delineate the centerline of the benthic transect, beginning at a permanent station buoy and extending 50 m (164 ft) away from the buoy along a pre-determined compass course. Some transects crossed over each other where a transect parallel to the depth contour crossed over a transect positioned perpendicular to the depth contour. The area common to both transects in these cases was approximately 2%. This small overlap did not affect the data summaries because the numbers of fish counted were averaged by area, and the mobility of most fish added to the independence of transects.

North Control PC: FO-2.

Field's Cove-Diablo ROckl*

Diabo Point San Luis \\

Intake Cove South Contrd' Figure 10. Locations of subtidal fish observation transects.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 16

7.0 Subtidal Fishes A survey team consisted of two divers. Each diver counted fish along the benthic and midwater transect sampling areas, swimming in opposite directions along the transect lines. This sampling technique allowed a more thorough inspection of potential fish habitats from all angles of view than would have been possible by a single diver progressing along a transect in only one direction. Fish were identified to species if possible, but juveniles of some species with similar appearances were combined into broader categories if necessary.

The resulting survey data per transect were the combined species counts of both divers, divided by two. This yielded an average count for each taxon per 50 m (164 ft) by 4 m (13 ft) benthic transect and per 50 m (164 ft) long by 4 m (13 fi) diameter midwater transect. During each survey, the stations (midwater and benthic transects) were usually sampled a second time (replicate two) within two weeks of the initial sampling effort (replicate one), unless adverse sea conditions precluded a second replicate. The data from the two replicates for each area were pooled separately for the three midwater transects, and the three benthic transects for each survey.

The survey mean abundance and standard deviation for each taxon within each of the four sampling areas for the four surveys during the year are presented in Appendix I-. The tables are further divided according to midwater and benthic transects in each area. The tables also show overall mean abundances for the entire year. The survey dates shown for each area in the tables represent the average date of the combined stations sampled in replicates one and two.

O ESLO201 5-005 PG&E

  • DCPP-RWMP 2014 Annual Report 17

8.0 Project Personnel 8.0 RWMP Project Personnel Project Personnel 2014 Tenera Environmental Princi~pal Investigator Project Manager:

Project Scientists:

Project Staff' Mr. John Steinbeck Mr. Jay Carroll Mr. Gery Cox Mr. Dan Dugan Mr. Chris Ehrler Mr. Andrew Harmer Ms. Tessa Lange Mr. Scott Kimura Dr. Joe Phelan Mr. Steve Pengilley Ms. Kristen Sanchez Mr. Jim Strampe Ms. Susan Helberg Pacific Gas and Electric Company Program Manager: Mr. Jim Kelly

¢/

ESLO2015-005 PG&E

  • DCPP-RWMP 2014 Annual Report 18

9.0 Literature Cited 9.0 Literature Cited Tenera Environmental, Inc. 1988. Diablo Canyon Power Plant, Final Report, Thermal Effects Monitoring Program, Volume 1. Pacific Gas and Electric Company, San Francisco, CA.

Tenera Environmental, Inc. 1997. Thermal effects monitoring program, analysis report:

Chapter 1 - Changes in the marine environment resulting from the Diablo Canyon Power Plant discharge. Pacific Gas and Electric Company, San Francisco, CA.

Tenera Environmental, Inc. 1999a. Receiving Water Monitoring Program - 1995-1997 Progress Report. Pacific Gas and Electric Company, San Francisco, CA.

Tenera Environmental, Inc. 1999b. Receiving Water Monitoring Program - 1995-1998 Progress Report. Pacific Gas and Electric Company, San Francisco, CA.

Tenera Environmental, Inc. 2002. Diablo Canyon Power Plant, Receiving Water Monitoring Program -

1995-2002 Analysis Report. Pacific Gas and Electric Company, San Francisco, CA fL' ESLO2015-005 PG&E

  • DCPP-RWMP 2014 Annual Report 19

Diablo Canyon Power Plant Appendix A Intertidal Temperatures

Appendix A - Intertidal Temperatures Table Al. Monthly statistical summary of intertidal temperatures (0C), Januaiy-December 2014, North Control Station NC 2 +0.6m (2+2).

Month Max Min Mean

.. Std. Dev N

Station: NC2 +0.6m Jan 14.60 11.90 13.30 0.60 1150 Feb 13.73 10.77 12.34 0.64 1006 Mar 14.73 11.18 12.92 0.65 1087 Apr 13.88 10.07 11.77 0.80 1036 May 14.68 9.95 12.35 1.00 1080 Jun 15.70 11.93 13.57 0.75 1102 Jul 19.27 13.15 15.87 1.14 1191 Aug 17.40 14.52 15.99 0.68 436 Sep Oct 16.15 13.80 14.93 0.61 188 Nov 16.63 14.30 15.46 0.50 1183 Dec 18.02 12.20 16.10 1.35 1186 a'

ESLO2015-05 A-1

Appendix A - Intertidal Temperatures Table A2. Monthly statistical summary of intertidal temperatures (°C), January-December 2014, Field's Cove Stations FC 1 +0.6m (4+2), FC 2 +0.6m (5+2) and FC 3

+0.6m (6+2).

Month Max Min Mean Std. Dev N

Station: FC I +0.6m Jan 16.27 11.75 14.18 0.83 1395 Feb 14.75 11.00 12.96 0.81 1231 Mar 15.20 11.40 13.20 0.73 1315 Apr 15.55 10.35 12.52 1.04 1257 May 16.35 10.27 13.14 1.32 1324 Jun 17.45 11.98 14.41 1.08 1334 Jul 21.60 13.55 16.99 "

1.47 1456 Aug 19.75 14.27 16.91 1.09

'1462 Sep 19.23 13.70 16.44 1.22 1436 Oct 20.42 13.55 16.91 1.57 1462 Nov 18.33 14.77 16.35 0.65 1378 Dec 19.48 12.93 16.87 1.24 1402 Station: FC 2 +O.6m Jan 16.33 11.90 14.24 0.83 1150 Feb 14.75 11.15 12.96 0.80 1006 Mar 14.88 11.48 13.16 0.71 1087 Apr 15.18 10.43 12.42 0.98 1036 May 15.75 10.25 12.96 1.20 1080 Jun 17.13 12.02 14.25 0.97 1102 Jul 20.95 13.45 16.79 1.37 1191 Aug 19.17 14.13 16.72 1.02 1228 Sep 19.08 13.73 16.37 1.14 1237 Oct 20.38 13.60 16.91 1.56 1275 Nov 18.40 14.77 16.39 0.63 1183 Dec 19.50 13.32 16.92 1.20 1186 Station: FC3 +0.6rn Jan 16.27 11.85 14.22 0.82 1150 Feb 14.75 11.13 12.94 0.79 1006 Mar 14.88 11.43 13.14 0.71 1087 Apr 14.88 10.40 12.36 0.95 1036 May 15.40 10.25 12.86 1.14 1080 Jun 16.63 12.00 14.12 0.90 1102 Jul 20.58 13.35 16.64 1.33 1191 Aug 18.92 15.50 16.96 0.84 516 Sep Oct-Nov 18.48 15.00 16.49 0.61 932 Dec 19.48 13.32 16.93 1.19 1186

' ESL02015-05 A-2

Appendix A - Intertidal Temperatures Table A3. Monthly statistical summary of intertidal temperatures (0C), January-December 2014, North Diablo Cove Stations NDC I +0.6m (7+2), NDC 2 +0.6m (8+2) and NDC 3 +0.6mn (9+2).

Month Max Min

Mean, Std. Dev N

Station: NDC 1 +O.6m Jan 21.80 12.05 16.77 1.77 1395 Feb 19.45 11.10 15.37 1.64 1231 Mar 19.25 11.55 14.31 1.63 1315 Apr 18.70 10.85 14.90 1.61 1257 May 19.83 10.48 15.30 1.80 1324 Jun 20.77 13.23 16.97 1.32 1334 Jul 23.00 15.05 19.40 1.38 1456 Aug 23.27 14.73 19.55 1.33 1462 Sep 23.05 14.10 19.32 1.46 1436 Oct 24.55 14.07 19.24 2.11 1462 Nov 22.20 14.90 19.05 1.26 1378 Dec 23.90 14.38 18.81 1.90 1402 Station: NDC 2 +O.6m Jan 21.42 12.13 16.93 1.75 1118 Feb 19.85 11.15 15.74 1.64 982 Mar 19.38 11.73 14.56 1.77 1051 Apr 19.33 10.88 15.30 1.67 996 May 20.27 10.63 15.77 1.74 1044 Jun 20.63 14.60 17.25 1.20 1062 Jul 22.95 14.60 19.60 1.39 1152 Aug 23.05 15.50 19.90 1.31 1194 Sep 22.77 14.27 19.59 1.40 1192 Oct 24.45 14.52 19.54 2.09 1245 Nov 22.45 15.07 19.22 1.23 1152 Dec 24.02 14.35 18.87 1.93 1150 Station: NDC 3 +O.6m Jan 22.13 12.07 17.08 1.81 1425 Feb 20.88 11.20 15.95 1.58 1247 Mar 20.48 11.80 14.72 1.88 1324 Apr 19.55 10.88 15.45 1.68 1266 May 20.17 10.48 15.71 1.71 1345 Jun 20.75 14.52 17.21 1.13 1349 Jul 22.98 14.48 19.49 1.33 1468 Aug 23.10 15.27 19.71 1.37 1481 Sep 22.92 14.38 19.53 1.43 1444 Oct 25.00 14.77 19.59 2.14 1476 Nov 23.52 15.07 19.35 1.26 1392 Dec 24.55 14.35 18.98 1.97 1423 8

ESLO2015-05 A-3

Appendix A - Intertidal Temperatures Table A4. Monthly statistical summary of intertidal temperatures (°C), January-December 2014, South Diablo Cove Stations SDC 1 +0.6m (10+2), SDC 2 +0.6m (11+2) and SDC 3 +0.6m (12+2).

Month i Max Min

, Mean, Std. 0ev -

N *,

Station: SOC 1 +O.6m Jan 24.48 14.18 18.07 2.15 1442 Feb 22.92 12.95 15.85 1.96 1262 Mar 23.60 13.70 17.44 2.36 1339 Apr 22.02 12.50 16.00 1.98 1281 May 21.63 12.57 16.22 1.95 1356 Jun 22.98 13.07 17.27 1.72 1365 Jul 23.85 15.38 19.11 1.61 1493 Aug 22.70 14.35 18.78 1.71 1507 Sep 23.73 15.43 18.73 1.43 1454 Oct 26.17 15.27 19.93 2.17 1488 Nov 25.48 15.60 18.95 1.76 1406 Dec 27.38 15.70 20.74 2.60 1438 Station: SOC 2 +0.6m Jan 23.02 13.23 17.06 1.31 1150 Feb 21.45 12.98 15.60 1.73 1006 Mar 22.77 13.43 16.37 1.85 1087 Apr 21.38 12.73 15.64 1.66 1036 May 21.38 12.68 16.36 1.91 1080 Jun 22.98 13.30 17.51 1.76 1102 Jul 23.65 15.18 19.30 1.63 1191 Aug 22.80 14.45 19.02 1.63 1228 Sep 22.23 15.48 18.82 1.33 1237 Oct 25.75 15.35 19.67 2.15 1275 Nov 23.65 15.38 18.52 1.24 1183 Dec 24.52 15.77 19.28 1.31 1186 Station: SOC 3 +O.6m Jan 19.08 12.93 16.59 0.94 1275 Feb 18.30 12.18 14.80 1.06 1131 Mar 18.73 12.70 15.22 1.14 1211 Apr 17.83 12.05 14.56 0.97 1153 May 18.85 12.18 15.09 1.30 1220 Jun 21.52 12.73 16.25 1.40 1228 Jul 22.20 15.02 18.42 1.49 1326 Aug 21.75 14.00 18.13 1.54 1358 Sep 21.58 15.02 18.15 1.30 1350 Oct 24.00 15.18 19.30 2.06 1376 Nov 20.63 15.35 18.25 0.97 1292 Dec 22.17 15.40 19.02 1.27 1307

¢ ES LO2015-05 A-4

Appendix A - Intertidal Temperatures Table A5. Monthly statistical summary of intertidal temperatures (°C), January-December 2014, South Diablo Point Stations SDP 1 +0.6m (22+2) and SDP 2 +0.6m (14+2).

SMointh

.Max Min

Mean Std.'Dev '

N Station: SOP 1 +O.6m Jan "

19.42 12.90 16.55 0.98 1506 Feb 18.45 11.77 14.81 1.13 1303 Mar 18.85 12.43 15.17 1.14 1386 Apr 17.38 12.00 14.51 0.98 1318 May 18.85 12.15 14.90 1.23 1405 Jun 19.63 12.45 15.95 1.33 1417 Jul 21.35 14.82 18.17 1.41 1551 Aug 21.88 13.90 17.82 1.55 1499 Sep 21.33 14.77 18.02 1.35 1496 Oct 24.13 15.15 19.28 2.08 1522 Nov 21.15 15.55 18.27 0.99 1450 Dec 22.50 15.57 19.00 1.28 1511 Station: SOP 2 +O.6m Jan 18.02 12.60 15.40 0.76 1395 Feb 16.77 11.23 13.71 0.82 1231 Mar 16.83 12.18 14.23 0.84 1315 Apr 16.23 10.93 13.72 0.83 1257 May 17.33 10.25 13.75 1.13 1324 Jun 18.27 12.48 14.87 0.87 1334 Jul 20.08 13.57 16.70 1.31 1456 Aug 20.40 13.45 15.91 1.24 1462 Sep 20.35 12.65 16.61 1.48 1436 Oct 22.02 13.90 17.52 1.80 1462 Nov 19.77 15.38 17.55 0.77 1378 Dec 20.98 15.07 17.99 1.04 1402

'*=*,ESLO2015-05 A-5

Appendix A - Intertidal Temperatures Table A6. Monthly statistical summary of intertidal temperatures (0C), January-December 2014, South Control Stations SC 1 +0.6m (19+2) and SC IV.

Month Max Min Mean Std. Dev N

Station: SC 1 +0.6m Jan 14.30 12.18 13.30 0.51 1262 Feb 13.35 11.00 12.29 0.56 1109 Mar 14.35 10.88 12.74 0.69 1189 Apr 12.95 9.93 11.27 0.65 1136 May 13.98 9.68 11.59 0.86 1197 Jun 15.25 11.27 12.97 0.79 1216 Jul 18.27 12.57 15.16 1.01 1306 Aug 16.48 13.55 15.13 0.70 311 Sep-----

Oct-Nov 16.63 14.85 15.55 0.44 877 Dec 17.98 13.00 16.23 1.16 1293 Station: SC IV Jan 14.90 12.13 13.35 0.62 1615 Feb 15.18 10.88 12.66 0.74 1396 Mar 15.85 11.20 13.31 0.88 1477 Apr 16.63 9.93 12.45 1.23 1414 May 18.25 10.23 13.53 1.69 1501 Jun 18.58 12.07 14.88 1.38 1519 Jul 21.77 13.73 17.08 1.45 1654 Aug 19.17 14.30 16.53 0.95 1666 Sep 18.92 13.32 16.14 1.07 1571 Oct 20.50 13.43 16.80 1.61 1598 Nov 17.20 14.00 15.64 0.63 1532 Dec 18.25 12.02 15.96 1.26 1606 aW

  • ESLO2015-05 A-6

Diablo Canyon Power Plant Appendix B Subtidal Temperatures

Appendix B - Subtidal Temperatures

  • Table Bi. Monthly statistical summary of subtidal temperatures (°C), January-December 2014, North Control Station NC 1 -3m (1-10).

,Month Max

Min Mean

,Std.Dev N

Station: NC 1 -3m Jan 14.82 11.93 13.38 0.57 2231 Feb 14.00 10.60 12.32 0.67 2016 Mar 14.57 11.10 12.89 0.65 2232 Apr 13.50 10.07 11.50 0.71 2160 May 14.00 9.93 11.77 0.85 2232 Jun 14.95 11.50 12.81 0.66 2160 Jul 18.42 12.75 15.23 1.02 2231 Aug 17.98 13.52 15.50 0.80 2232 Sep 17.77 13.15 15.32 1.05 2160 Oct 19.77 13.10 16.47 1.52 2232 Nov 16.67 14.32 15.55 0.47 2159 Dec 18.15 12.73 16.19 1.26 2232 Table B2. Monthly statistical summary of subtidal temperatures (°C), January-December 2014, Field's Cove Station FC 1 -3m (22-10).

Month... Max*

ai.

Mm Mean Std. Dev...

N Station: FC I -3m Jan 16.35 12.05 14.31 0.84 2231 Feb 14.77 10.80 12.95 0.84 2016 Mar 15.13 11.23 13.18 0.72 2232 Apr 14.73

  • 10.43 12.32 0.92 2159 May 14.77 9.93 12.50 0.99 2232 Jun 15.93 11.88 13.57 0.72 2159 Jul
  • 18.85 12.95 15.83 1.05 2232 Aug 18.52 13.77 16.13 0.96 2232 Sep 18.55 13.45 16.09 1.09 2160 Oct 20.42 13.65 16.95 1.52 2232 Nov 18.60 14.85 16.46 0.66 2160 Dec 19.65 13.63 17.00 1.20 2232 a#

ESLO2015-05 B-i

  • g~

V¢0" L0'61 8"1.

954'£g9 oa(o 691.Z V9'1.

0*'61.

£614.

  • 0't7 AON LI, LO'8, I£"1, l'£V2 loO 091.*

L9'1-059'1.

05'51, 96';

des 1.5Z 99'1.

6T91.

947"44 51,V5 6n 091.

0991.

90'91.

99'01.

55.61.

,ieV 09512 1.61.

09449 991.1.

9g61, iJdA
  • 512 4791.
LVLI, 51,ZI, 09'12 uer W47-

,p OO

uo!Rl.

091,*

89¢' I 9L'61, 05'91.

0L4Z

^ON 1212 L*';

69'61.

9474I, 59'9*

10 091.*

9V'1.

90'61.

59"5l.

91.'g; des 091.*

91.1.

1891.

LL'51.

99'0*

unp 1212 69'1.

49'91.

95'01.

0L'61,

ABLI, 091.Z

£91.

99'91.

£6'01.

Z0'0*

Idv 91.0*

6L'l.

ZL.'91.

0£1'lI.

59"12 qe.4 I.£12

£0Z 47L'L1 91.Z1 L*'5*

uep' Wl;- £ 30N :uop, e*,

091.*

L£'l.

99'61.

L0'91.

g9'5*

^ON 1212 12'*

99'61.

0914l 9'9*

100 091.*

94I, Zl1'61, 12'51.

90'5 des 1212 1.471

££'61.

LL'7l, L*'*

5n 091.*

1,'1.

L9'91.

9951l.

0L'0a unr 1212 09'1.

94791.

9£'01.

0661.

,BIeJ 091.*

19'1.

6V9l.

99010.

9961.

d 1.£12 69'1.

55'Z1.

0V1,Z.

9£'2 uer tug" Z ON :uo!, e*,

N A8' P1a"p~.

u96lAJ ui~f Xe/iJ 1fUOj/*,

pue '(01-6) tU1-

£ cxit' '(0[-8) "tu-Z: ;3Q[4 suoimS 0AOE) o~q*!u tp.oN 'vi0.* oquio~oG-kr*nnur

'(Do) seinwiodwe*

F~pilqns jIo £rnunns [13!1sws,XlqlUO!A "£ f qf I seinleJedwej le~p, qnl

- g] x~pueddv

Appendix B - Subtidal Temperatures Table B4.

Monthly statistical summary of subtidal temperatures (°C), January-December 2014, South Diablo Cove Stations SDC 1 -3m (11-10) and SDC 4 -4m (11-15).

Month Max Min Mean

'Std.

Dev N

Station: SOC 1 -3m Jan 24.42 13.18 17.04 1.97 2232 Feb 21.25 11.65 14.69 1.74 2016 Mar 22.17 12.55 16.11 1.71 2232 Apr 20.98 11.05 14.84 1,83 2160 May 20.35 10.60 14.23 1.77 2231 Jun 21.30 11.82 14.51 1.79 2160 Jul 22.45 12.00 15.89 1.71 2232 Aug 22.38 12.93 16.15 1.83 2231 Sep 22.23 12.95

  • 16.69 1.74 2160 Oct 24.27 13.00 18.38 2.31 2232 Nov 24.50 14.80 18.36 1.75 2160 Dec 26.98 14.30 19.34 2.00 2232 Station: SOC 4 -4m Jan 23.25 12.90 15.92 2.00 2232 Feb 18.25 11.02 13.70 1.37 2016 Mar 20.75 11.20 15.28 1.61 2232 Apr 19.73 9.98 13.34 1.90 2160 May 18.77.

9.73 12.43 1.56 2232 Jun 17.90 11.02 12.70 1.25 2160 Jul 18.60 11.63 14.29 1.11 2232 Aug 19.10 12.35 14.68 1.09 2231 Sep 21.63 12.35 15.11 1.46 2160 Oct 23.33 12.50 17.35 2.21 2232 Ncv 23.83 14.50 17.28 1.73 2160 Dec 25.90 13.75 18.59 2.16 2232 aw--ESLO2015-05 B-3

Appendix B - Subtidal Temperatures Table B5. Monthly statistical summary of subtidal temperatures (°C), January-December 2014, South Control Stations SC 1 -3m (19-10) and SC 2 -6m (20-20).

Month Max' Min Mean Std. Dev N

Station: SC 1 -3m Jan 14.55 12.18 13.37 0.51 2232 Feb 13.75 10.80 12.32 0.59 2016 Mar 14.40 10.93 12.80 0.71 2232 Apr 13.05 9.90 11.29 0.68 2160 May 13.98 9.68 11.45 0.83 2232 Jun 14.35 11.10 12.62 0.65 2160 Jul 18.08 12.10 14.77 1.03 2232 Aug 17.38 13.00 14.87 0.85 2232 Sep 17.73 12.35 14.90 0.90 2160 Oct 19.58 12.90 16.39 1.61 2232 Nov 16.67 14.50 15.57 0.44 2160 Dec 18.08 12.85 16.22 1.16 2231 Station: SC 2 -6m Jan 14.40 12.18 13.36 0.49 2232 Feb 13.35 10.82 12.22 0.56 2015 Mar 14.02 10.75 12.67 0.70 2232 Apr 12.65 9.73 11.02 0.62 2160 May 13.43 9.40 11.01 0.74 2232 Jun 13.77 10.52 11.96 0.64 2160 Jul 17.38 1.1.23 14.12 1.05 2232 Aug 17.17 12.20 14.38 0.91 2231 Sep 17.52 12.13 14.51 0.89 2160 Oct 19.52 12.55 16.27 1.63 2232 Nov 16.85 14.57 15.53 0.43 2159 Dec 17.92 13.32 16.25 1.11 2232 4

  • ESLO201 5-05B-B-4

Diablo Canyon Power Plant Appendix C Intertidal Algae, Invertebrates and Substrates

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C1. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 1+0.3m (1+1).

Survey 176 177 178 179 Survey Date 16-Jan-14 12-May-14 12-Aug-14 27-Oct-14 Std.

Std.

Std.

Std. jAnnual Taxon Mean Dev.

Mean 0ev.

Mean Dev.

Mean Dev.

Mean AIgae Cover Phy//ospadix spp.

Mazzaella flaccida nlon-coralline crust Gastroc/onium subart/culaturn Chondracanthus canaliculatus Mazzae//a affinis Ge/idiurn coulteri coralline crust Cryptopleura violacea Cod/urn setchelihi Mastocarpus papillatus Smithora naiadurn Egregia mnenz/esfi Plerosiphonia dendroidea filamentous red algae complex Prionitis spp.

Mastocarpus lard/nil Corallina vancouver/ens/s Callian'hron/Bossie//a spp.-complex AMazzaella ore gona Endocladia mur/cata U/va spp.

Me/obesia med/ocr/s Ge/id/urn pusi//urn Mazzael/a sp/endens M/croc/adia cou/teri Sarcod/otheca gaud/chaud//

Cora//ina oh//ens/s Osmundea spp.

Chrysophyta Chlorophyta (filamentous)

Ca//ithamnion pikeanum Cryptopleura ruprechtiana Grate/oupia ca/ifornica Neorhodomela /ar/x juv. articulated coralline algae Mazzae/la /eptorhynchos Cryptosiphonia wood/i E~rythrophy//um de/esserioides C/adophora spp.

Porphyra spp.

Ca//ophy//is spp.

Po/yneura /at/ssirna Delesseriaceae (iuv.A 22.0 24.7 13.3 8.3 22.2 18.7 10.8 11.3 7.5 7.2 11.0 8.0 6.7 6.1 3.7 3.2 0.5 0.9 3.7 7.6 0.8 1.3 0.6 1.2 1.8 1.5 3.4 5.7 1.6 3.2 0.8 1.0 1.7 3.2 1.8 5.0

<0.1 0.2 0.8 2.6

<0.1

<0.1

<0.1

<0.1 0.3 0.6

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 21.6 27.9 37.9 15.8 10.3.

12.1 7.7 7.1 12.0 8.4 11.5 13.2 2.3 3.3 8.6 8.7 3.0 3.6 1.7 3.8 3.1 2.0

<0.1

<0.1 0.9 2.9 3.5 6.9 1.8 4.0 1.8 4.4 0.9 1.5 1.0 1.5 0.4 0.9 2.6 2.1 1.6 5.1

<0.1

<0.1

<0.1

<0.1 0.5 1.5 0.2 0.7 0.3 0.9

<0.1

<0.1

<0.1

<0.1 0.4 1.3 0.3 0.9 0.2 0.5

<0.1

<0.1

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 29.1 22.6 16.9 9.4 6.9 9.5 8.3 3.1 4.0 3.2 1.9 5.5 5.0 0.3

<0.1 0.4 1.2 0.4 0.2

<0.1 0.1 0.6

<0.1

<0.1 0.5 0.2 0.2 0.1

<0.1

.0.2 0.1

<0.1

<0.1

<0.1

<0.1 31.0 11.2 16.7 6.9 5.0 8.2 7.5 3.1 3.6 5.8 1.8 8.7 15.8 1.1 0.2 1.3 2.8 0.7 0.7

<0.1 0.4 1.3

<0.1

<0.1 1.5 0.7 0.5 0.4

<0.1 0.7 0.4

<0.1

<0.1

<0.1

<0.1 40.1 36.5 14.9 14.5 10.2 9.3 17.2 13.1 11.6 10.3 5.1 4.4 4.5 6.6 3.7 4.8 5.6 6.6 4.2 6.8 2.0 4.7 1.7 2.5 0.1 0.4

<0.1 0.2 0.7 1.5 1.0 1.3 0.2 0.7 0.3 0.7 0.8 1.7 1.2 1.2 0.3 0.7 0.3 0.5

<0.1 0.2 0.3 0.8 0.4 0.7 0.2 0.5

<0.1

<0.1

<0.1 0.2

<0.1

<0.1 28.2 22.2 14.9 11.3 9.5 9.3 5.5

  • 4.8 3.3 3.2 1.9 1.8 1.7 1.4 1.3 1.1 1.0 0.8 0.7 0.7 0.6 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (tab/e continued) 0W ESLO2015-05 C-1

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C1 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for North Control Station NC 1+0.3m (1+1).

Survey 176 177 178 179 Survey Date 16-Jan-14 12-May-14 12-Aug-14 27-Oct-14 Std.

Std. IStd.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Invertebrate Counts Pa gurus spp.

Chlorostoma funebralis Tetraclita rubescens Chloro stoma brunnea Leptasterias spp.

Fissurella volcano Pugettia spp.

Epiactis prolifera Lottia pelta Lottia scutum Ocinebrina spp.

Nernertea Pachygrapsus crassipes Lottia limatula Anthopleura elegantissirna Mopalia spp.

Lottia scabra Romaleon antennarius Balanus spp.

Mitra idae Lacuna spp.

Alia spp.

Crepidula spp.

Lottiidae Heptacarpus spp.

Sipuncula Barleeia spp.

Onchidella borealis Epitonium/Opalia spp.

Pycnogonida Petrolisthes spp.

Ischnochitonidae Lirobittium s pp.

Pelecypoda boring Eulithidium spp.

Lissothuria nutriens Romaleon jordani Grapsidae Homolo. luridum/Lirularia succincta Betaeus spp.

11.8 9.6 12.2 8.4 3.4 5.0 3.0 6.2 1.0 1.2 1.0 1.7 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1 0.2 0.4 0.4 0.9 0.4 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.8 11.6 12.2 10.0 16.2 33.0 3.4 4.2 1.4 2.2 0.2 0.4 0.6 0.9 0.2 0.4 0.6 0.9 0.2 0.4 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 12.4 10.8 3.8 4.1 0.4 0.5 1.8 2.5 0.6 1.3 0.6 0.5 0.6 1.3 0.4 0.9 0.6 1.3 0.2 0.4 0.8 1.3

<0.1

<0.1 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.0 5.6 13.2 7.3 8.4 18.8 0.8 0.8 0.8 0.4 0.6 0.9 0.4 0.9 0.4 0.9 0.4 0.5 0.6 0.5 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.0 10.4 7.0 1.9 1.3 0.6 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued) a'*ESLO2015-05 C-2

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C1 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC l+0.3m (1+1).

Survey 176 177 178 179 Survey Date 16-Jan-14 12-May-14

,,12-Aug-14 27-Oct-14 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev.

Mean,,'ev.,

Mean 0ev.

Mean 0ev.

Mean Invertebrate Cover Pistaspp.

20.2 18.7 5.9 7.0 23.1 17.4 20.5 13.9 17.4 tunicates, compound/social 0.2 0.7 0.1 0.4

<0.1

<0.1 0.3 0.9 0.2 Phragmatopoma californica

<0.1

<0.1

<0.1

<0.1 0.6 1.8 0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Chthamalus fissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Salmnacina tri branchi ata

<0.1

<0.1

<0.1 Substrate Cover sand (shell gravel) 7.8 8.1 23.5 27.4 7.1 5.5 14.8 13.3 13.3 rock 1.4 1.4 7.1 7.7 3.8 4.1 6.4 6.4 4.7 cobble 1.4 1.8 0.4 1.3 0.3 0.9 0.3 0.8 0.6

'ESLO2015-050-C-3

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C2. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 1+0.9m (1+3).

'.. Surveyj 176

177, 178...

179

, Survey Date.

16-Jan-14,

12-May-14 12-Aug-14..

.,27-Oct-14 I*

Std.

Std.,

Std...

oStd,
Annual Taxon Mean" Dev.,

Mean.

0ev.,

Mean, 0ev.,

Mean

, Dev.

,Mean Algae Cover Mazzaella flaccida Endocladia muricata non-coralline crust Mastocarpus papillatus coralline crust Silvetia compressa Gelidium coulteri Mazzaella affinis Codium setcheillii Mastocarpus jardinfi Chondracanthus canaliculatus Gefidium pusillum Cryptopleura violacea Corallina vancouveriensis Analipus laponicus Mazzaella ore gona Phyllospadix spp.

Prionitis spp.

Mazzaella leptorhynchos juv. articulated coralline algae Porphyra spp.

Gastroclonium subarticulatum Ulva spp.

Cladophora spp.

Callithamnion pikeanum Calliarthron/Bossiella spp.-complex filamentous red algae complex 18.5 19.3 28.1 11.2 10.6 6.7 3.5 6.3 4.6 2.0 1.7 2.4 0.3 0.3

<0.1

<0.1 0.5

<0.1 0.3

<0.1

<0.1

<0.1 61.4 9.0 2.0 0.6 2.8 0.8 1.0 0.4 0.6 0.2 0.2 13.0 17.7 15.8 8.3 9.2 16.2 4.5 8.6 10.0 2.6 2.2 2.3 1.1 0.5 0.2 0.2 1.1

<0.1 0.8 0.2

<0.1

<0.1 66.2 12.4 4.5 0.9 2.4 1.8 1.2 0.9 0.5 0.4 0.4 20.7 24.0 17.9 20.3 13.0 4.2 1.0 2.4 3.5 0.4 1.8 1.5

<0.1 1.1

<0.1 0.7 0.8

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 52.6 9.4 5.2 5.4 0.2 2.2 1.0 1.6 1.4 1.4 0.6 0.2 0.2 0.2 0.4 11.3 12.0 8.7 6.5 7.6 8.9 1.3 5.6 7.3 0.9 3.1 2.6 0.2 1.5 0.2 1.0 1.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 65.1 14.5 11.6 8.1 0.4 4.9 0.7 3.0 2.6 1.1 0.5 0.4 0.4 0.4 0.9 37.2 16.0 16.0 13.4 14.6 12.2 21.0 9.0 5.3 4.9 6.7 13.5 5.3 7.3 3.7 5.2 3.5 8.4 3.1 6.6 0.5 0.8 0.4 1.3 0.8 2.4 0.1 0.4 0.4 1.3

<0.1

<0.1 0.1 0.4 0.1 0.4

<0.1

<0.1 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 43.0 44.4 4.6 4.6 6.2 11.6 1.8 2.5 1.0 1.4 0.8 1.3 2.6 3.1 2.4 4.8 1.4 1.5 0.8 1.3 0.6 1.3 0.2 0.4 0.4 0.5 19.1 25.2 23.8 21.0 9.8 9.1 5.8 2.8 3.5 2.4 1.7 1.0 1.9 0.4 0.5 0.1

<0.1 0.3

<0.1

<0.1 0.2

<0.1

<0.1 20.8 7.0 6.4 2.8 5.6 4.4 0.8 1.2 0.8 0.2 0.2 11.0 24.7 11.8 10.7 8.8 22.9 4.6 4.0 7.6 1.6 1.7 1.6 5.9 0.7 1.5 0.4 0.2 0.6

<0.1 0.2 0.7

<0.1

<0.1 20.0 8.9 14.3 5.2 7.3 9.8 0.8 2.2 1.8 0.4 0.4 23.9 21.1 21.1 18.4 9.7 6.7 3.9 3.8 3.8 2.0 1.4 1.3 0.8 0.5 0.3 0.2 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 44.5 7.5 4.7 2.7 2.4 2.1 1.4 1.3 1.0 0.8 0.3 0.2 0.2 0.2 0.1 Invertebrate Counts Chiorostoma funebralis Pagurus spp.

Pollicipes polymerus Tetraclita rubescens Ant hopleura elegantissima Lottie scabra Lottia limatula Lottie scutumn Nuttallina californica Pachygrapsus crassipes Leptasterias spp.

Nemertea Hemnigrapsus nudus Ocinebrina spp.

Lottia celta (table continued)

  • LESLO2015-05 C-4

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C2 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 1+0.9m (1+3).

Survey *.. 176

[

1 77 178...

179

  • ,Survey Date 16-Jan-14...

, 12-May-14 12-Aug-14 r,,

27-Oct-14

, ', Std. f Std.

Std.

Std.

Annual Taxon

,Mean

... 0ev.

Mean... 0ev.

Mean...

0ev.

,Mean Dev.

-Mean Invertebrate Counts (continued)

Fissurella volcano Haliotis spp.

Epiactis prelifera Cancridae Lottiidae Crepidula spp.

Pelecypoda boring Grapsidae Hormolo. luridum/Lirularia succincta Ischnochitonidae Sipuncula Alia spp.

Litterina spp.

Petrolisthes spp.

Lirobittium spp.

Cryptolithodes sitchensis Lacuna spp.

Pugettia spp.

Invertebrate Cover Phragmatopoma californica Spirorbidae Chtharnalus fissus tunicates, compound/social Haliclona spp.

Sa/macina tribranchiata Porifera (encrusting) bryozoa (encrusting)

Substrate Cover rock cobble sand (shell gravel) 0.2 0.4 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.4 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 13.2 8.4 2.8 8.8

<0.1

<0.1 0.1 0.3 0.2 0.4

<0.1

<0.1

<0.1

<0.1 0.3 0.9

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 13.8 12.8 3.8 8.3 0.2 0.7 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.3

<0.1

<0.1

<0.1

<0.1 8.8 1.4 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.9

<0.1

<0.1

<0.1

<0.1 10.6 3.9 0.3 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 10.9 2.5

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 7.6 1.9

<0.1 0.7

<0.1

<0.1

<0.1

<0.1

<0.1 6.9 4.2

<0.1 r

ESLO2015-05 C-5

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C3. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 2+0.3m (2+1).

-Survey

,176 I

,177 1

78

,179

','Survey Date

  • 13-Feb-14

.,,, 30-May-14

°24-)ul-14*

1, 4-Nov-14 Taxon "Meani_

Dev.,

Mean Dev.'

Meani Dev.£ Meani Dev.

Mean Algae Cover Phyllospadixs pp.

14.0 16.7 16.5 11.7 21.5 20.0 27.6 21.6 19.9 Mazzaellaflaccida 11.9 3.0 29.4 13.6 22.5 12.2 13.0 12.3 19.2 Chondracanthus canaliculatus 11.0 8.8 21.0 6.6 19.7 8.5 11.7 7.1 15.9 non-coralline crust 18.7 7.1 15.0 9.7 12.3 10.6 16.5 8.4 15.6 Gastrocloniumsubarticulatum 11.7 8.4 8.7 8.0 21.9 20.6 14.1 7.5 14.1 Mazzaella affinis 16.3 7.8 9.4 6.2 5.7 5.5 7.6

.5.3 9.8 Egregia menziesii 0.7 1.1 8.3 16.2 12.2 13.5 0.3 0.9 5.4 Gelidium coulteri 3.1 2.8 3.4 6.3 5.1 2.9 3.1 3.5 3.7 Codium setchellfi 5.6 8.0 3.3 7.3 1.4 3.3 2.4 4.7 3.2 filamentous red algae complex 4.5 5.8 5.8 6.3 2.3 5.1

<0.1 0.2 3.2 coralline crust 2.4 2.6 1.5 1.3 2.9 3.4 2.4 2.2 2.3 Mastocarpus papillatus 3.0 6.8 3.1 4.0 2.5 3.3

<0.1 0.2 2.2 Mastocarpus jardinii 0.9 1.7 2.1 3.9 1.1 2.1 1.1 1.5 1.3 Ulva spp.

0.3 0.5 0.7 2.0 1.6 2.6 1.7 2.0 1.1 Neorhodomela larix 1.0 2.0 1.1 2.2 0.8 1.6 0.1 0.4 0.7 Cryptopleura violacea 0.1 0.4 0.8 1.5 0.8 1.1 1.0 1.1 0.7 Pterosiphonia dendroidea

<0.1

<0.1

<0.1

<0.1 2.4 2.8 0.6 Prionitis spp..0.3 0.9 0.1 0.4 0.4 0.7 1.3 2.6 0.5 Smithora naiadumn

<0.1

<0.1 0.4 1.3 1.5 1.7

<0.1

<0.1 0.5 Corallina vancouveriensis 0.6 1.0

<0.1 0.2

<0.1

<0.1 0.7 1.0 0.3 Mazzaella oregona 0.1 0.3 0.6.

1.0 0.3 0.4

<0.1 0.2 0.3 Microcladia coulteri

<0.1

<0.1

<0.1

<0.1 0.6 0.7 0.3 0.8 0.2 Melobesia mediocris

<0.1

<0.1 0.3 0.9 0.3 0.9 0.3 0.9 0.2 Mazzaella splendens 0.4 1.1 0.2 0.7 0.2 Mazzaellaleptorhynchos 0.3 0.7

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 0.1 Chondracanthus coyrymbiferus 0.1 0.4 0.1 0.4 0.1 0.4 0.1 Osmundeaspp.

<0.1 0.2

<0.1 0.2 0.1 0.3

<0.1 Corallina chilensis 0.3 0.9

<0.1

<0.1

<0.1 Callithamnion pikeanum

<0.1

<0.1 0.3 0.9

<0.1 juv. articulated coralline algae

<0.1

<0.1

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1 Gelidium pusillum

<0.1

<0.1

<0.1

<0.1 0.2 0.7

<0.1 Endocladia muricata 0.2 0.5

<0.1

<0.1

<0.1 Soranthera ulvoidea 0.2 0.5

<0.1 Calliarthron/Bossiella spp.-complex

<0.1 0.2

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1 Crypto pleura ruprechtiana

<0.1

<0.1 0.1 0.4

<0.1 Halymenia/Schizymenia spp.-complex

<0.1 0.2

<0.1 Cladophoraspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Sarcodiotheca gaudichaudii

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Acrosiphonia spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Grateloupia californica

<0.1

<0.1

<0.1

<0.1

<0.1 Porphyra spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Cryptcsiphonia woodii-

<0.1

<0.1

<0.1 Gelidium robustumn

<0.1

<0.1

<0.1 Laminariales

<0.1

<0.1

<0.1 Chlorophyta (filamentous)

<0.1

<0.1

<0.1 (table continued)

't ESLO2015-05 C-6

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C3 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey rffeans, standard deviations and 2014 annual means for North Control Station NC 2+0.3m (2+1).

S*

i" :i urvey 176 T

i77 178

,179 Survey Date 13-Feb-14" 30-May-14 24-Jul-14

'4-Nov-14 Std. I

.. Std."

° Std.

  • Std.

Anniual

,Taxon

Mean,

,Dev.

  • Mean 0 ev.

Mean'

.Dev.

Mean, 0 ev.

,,Mean Invertebrate Counts Pa gurus spp.

Tetraclita rubescens Chiorostoma funebralis Epiactis prolifera Chiorostoma brunnea Anthopleura elegantissima Fissurella volcano Lot/ia pe/ta Pugettia spp.

Nemertea Lottia scabra Leptasterias spp.

Lottia scutumn Loltia limatula R~ostanga pu/chra Anthopleura artemisia Serpu/orbis squamigerus Romaleon jordani Mopalia spp.

Hemigrapsus nudus Pachygrapsus crassipes Lacuna spp.

Crepidula spp.

Alia spp.

Cancridae Lottiidae Pycnogonida Lirobittium spp.

Lissothuria nutriens Ha/campa decemntentaculata lschnochitonidae Tonicella lineata Idotea spp.

Sipuncula Stenoplax s pp.

Grapsidae 13.6 10.8 7.6 17.0 7.6 2.5 0.6 0.5 1.2 1.6 1.0 1.0 0.4 0.9 0.2 0.4 0.2 0.4 0.4 0.5 0.2 0.4 0.4 0.9 0.6 1.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 14.3 5.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 7.0 4.5 3.8 5.5 3.4 4.2 5.0 6.9 3.6 4.1 2.6 5.2 0.6 1.3 1.2 2.7 0.4 0.5 0.2 0.4 1.2 2.2 1.2 1.3 0.6 1.3 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 9.6 2.4 1.2 4.8 2.0 0.2 1.0 0.2 0.4 0.4 0.6 0.4 0.8 0.6 0.4 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.3 0.6 0.3

<0.1

<0.1

<0.1 7.4 5.4 1.3 5.4 2.0 0.4 1.2 0.4 0.5 0.5

.1.3 0.9 1.1 1.3 0.9 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 10.1 2.2 0.9

<0.1

<0.1

<0.1 8.2 3.6 4.0 4.2 4.2 4.0 1.8 1.2 1.0 1.0 0.2 0.2 0.6

<0.1

<0.1

<0.1

<0.1

<0.1 9.3 8.0 4.9 6.3 5.8 7.8 4.0 2.7 1.7 1.7 0.4 0.4 1.3

<0.1

<0.1

<0.1

<0.1

<0.1 9.6 4.4 4.1 3.7 2.8 2.0 1.0 0.7 0.5 0.5 0.5 0.5 0.4 0.4 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 12.8 0.2

<0.1

<0.1

<0.1

<0.1 Invertebrate Cover Pista spp.

tunicates, compound/social Porifera (encrusting)

Phragmatopoma californica bryozoa (encrusting)

Spirorbidae 8.7

<0.1

<0.1

<0.1

<0.1

<0.1 6.1

<0.1

<0.1

<0.1

<0.1

<0.1 19.7 17.9 0.1 0.4

<0.1

<0.1 0.2 0.7

<0.1 0.2

<0.1

<0.1 (table continued)

ESLO2O15-05 C-7

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C3 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 2+0.3m (2+1).

Survey 176 i

177.

1,'

'2i78"

-179...,,,

SUrveyDate'

.... 13-Feb-14.,

30,May-14 24"Jul-14 4-Nov-14 Std:

Std.

Std

' Std.

Annual Taixon

,Mean Dev.

Mean.

Dev.

Melan, 0:ev.

Mean 0 ev.

Medn, Invertebrate Cover (contin ued)

Chthamalusfissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Salmacinatribranchiata

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Substrate Cover sand (shell gravel) 3.3 3.2 13.7 15.8 5.8 4.1 11.0 8.5 8.5 rock 3.1 1.9 6.6 9.5 11.8 13.9 5.0 3.7 6.6 cobble 2.8 4.6 0.8 2.0 0.8 1.8 1.0 2.3 1.4 a--w ESLO2015-105 C-C-8

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C4. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 2+0.9m (2+3).

'*i,,

Survey{

176' 177*,.,

178, J, 1..

79,

} '

Survey Date, 13-Feb-14' 30-May-14 24-aulM4..

,,4-Nov-14

.Stdt Std."

'Std.

'Std.

Annual

,Taxon

,Mean 0Dev. Mean 0 ev.

,Mean 0ev.

Mean Dev.

,Mean Algae Cover Endocladia mnuricata 30.5 21.7 32.8 22.5 37.3 23.3 32.7 24.0 33.3 non-coralline crust 28.3 10.0 19.6 5.8 11.6 8.2 22.5 11.2 20.5 Mastocarpus papillatus 11.7 6.4 22.3 13.5 26.8 12.4 14.4 6.6 18.8 Mazzaella flaccida 5.7 6.5 13.2 9.4 16.6 13.4 10.6 9.8 11.5 Mazzaella affinis 9.4 7.0 9.4 10.4 5.3 5.9 9.7 8.6 8.5 coralline crust 6.3 5.3 2.8 4.5 6.3 9.3 3.7 3.1 4.8 Mastooarpusjardinfi 0.8 0.9 1.3 2.1 3.4 4.0 3.5 5.2 2.3 Gelidiurn coulteri 1.1 1.2 0.2 0.5 3.3 3.9 1.4 1.6 1.5 Chondracanthus canaliculatus 0.8 1.4 0.3 0.9 0.8 1.8 1.1 2.9 0.7 Corallina vancouveriensis 1.5 2.4 0.6 1.8

<0.1 0.2 0.4 1.3 0.6 Porphyraspp.

<0.1

<0.1 0.8 1.4 0.7 1.1

<0.1

<0.1 0.4 Gelidium pusillum 0.3 0.8

<0.1 0.8 1.2 0.3 Calliarthron/Bossiella spp.-complex

<0.1

<0.1 0.7 2.2 0.1 0.4 0.2 Gastrocloniurn subarticulaturn 0.1 0.4 0.3 0.9 0.1 filamentous red algae complex

<0.1

<0.1 0.4 1.3 0.1 Mazzaella ore gone

<0.1

<0.1

<0.1

<0.1 0.3 0.6

<0.1 Prionitis spp.

0.1 0.4

<0.1

<0.1

<0.1 0.2 0.1 0.4

<0.1 Cryptopleura violacea

<0.1

<0.1

<0.1

<0.1 0.3 0.8

<0.1 Mazzaella splendens 0.3 1.1

<0.1 Mazzaella leptorhynchos 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1 Silvetia cornpressa

<0.1

<0.1 0.2 0.7

<0.1

<0.1

<0.1 juv. articulated coralline algae

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Fucus gardneri

<0.1 0.2

<0.1

<0.1

<0.1 Cladophora spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Ulva spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Phyllospadix spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Hesperophycus californicus

<0.1

<0.1

<0.1 Smithora naiadumn-

<0.1

<0.1

<0.1 Chondracanthus coyrymbiferus

<0.1

<0.1

<0.1 Osmnundeaspp.

<0.1

<0.1

<0.1 Chlorophyta (filamentous)

<0.1

<0.1

<0.1 Invertebrate Counts Chlorostoma funebralis 101.2 64.7 120.8 108.0 58.2 26.8 82.2 81.8 90.6 Anthopleura elegantissirna 10.8 6.1 9.2 4.4 6.8 4.3 13.0 14.2 10.0 Lottia scabra 3.2 2.3 2.8 3.1 7.0 7.3 8.6 12.7 5.4 Pagurus spp.

8.0 8.7 5.8 4.1 3.8 3.9 0.4 0.5 4.5 Lottia scutum 2.6 3.2 2.2 3.0 3.0 1.0 0.8 1.3 2.2 Lottiaflimatula 1.0 1.0 1.4 1.7 2.4 0.5 1.8 2.0 1.7 Tetraclita rubescens 0.2 0.4 2.8 5.2 0.4 0.9 0.9 Pachygrapsus crassipes 0.2 0.4 2.0 1.2 0.6 0.9 0.7 Lottia pelta 0.4 0.5 0.8 0.8 0.2 0.4 0.8 1.3 0.6 Ocinebrina spp.

1.2 0.8 0.2 0.4 0.2 0.4 0.6 0.9 0.6 Acanthinucella spp.

0.4 0.5 0.4 0.9 0.2 0.4 0.3 (table continued)

L/ESLO2 015

-.0 5 C-9

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C4 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Control Station NC 2+0.9m (2+3).

Surv'ey 176 177 178 179 Survey Date "13-Feb-14 30-May-14 "24-Jul-14 4-Nov-14 Std. IStd.

Std.

Std.

Annual Taxon Mean Dev.

Mean Day.,

Mean Dev.

Mean, Dev.

Mean Invertebrate Counts (continued)

Mopalia spp.

0.4 0.5 0.2 0.4 0.2 0.4 0.2 Leptasterias spp.

0.2 0.4 0.4 0.9 0.2 Nemertea 0.2 0.4 0.2 0.4 0.1 Calliostoma annulatum 0.2 0.4

<0.1 Nucella spp.

0.2 0.4

<0.1 Nuttalilna californica 0.2 0.4

<0.1 Hemigrapsus nudus 0.2 0.4

<0.1 Strongylocentrotus purpuratus 0.2 0.4

<0.1 Lottiidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Crepidulaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Littorinaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Epiactis prolifera

<0.1

<0.1

<0.1 Ischnochitonidae

<0.1

<0.1

<0.1 Lacuna spp.

<0.1

<0.1

<0.1 Pugettia spp.

<0.1

<0.1

<0.1 Sipuncula

<0.1

<0.1

<0.1 Barleeia spp.

<0.1

<0.1

<0.1 Triopha spp.

<0.1

<0.1

<0.1 Mytilus spp.

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1 Invertebrate Cover Chthamalus fissus

<0.1

<0.1

<0.1 0.2 0.7

<0.1

<0.1 Phragmnatopoma califomica

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 0.1 0.4

<0.1 Haliclona spp.

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 tunicates, compound/social

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Salmacina tribranchiata

<0.1

<0.1

<0.1

<0.1

<0.1 Substrate Cover rock 6.7 5.9 6.5 5.9 9.1 9.3 8.3 4.9 7.6 cobble 9.9 8.4 8.1 7.7 7.5 6.2 4.9 5.5 7.6 sand (shell gravel)

<0.1

<0.1 0.4 1.3 0.6 2.0 0.6 2.0 0.4

¢*/

'ES L02O15-05 C-10

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C5. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC l+0.3m (4+1).

Survey 176 177 178 179 Survey Date 13-Jan-14 11-Jun-14 9-Jul-4 10-Oct-14 i

Std.

Std; Std.

Std.

Annual Taxon',

,.Mean, Dev.

Mean Dev.:

Mean 0ev.

Mean 0 ev..

Mean Algae Cover non-coralline crust 34.0 9.9 22.0 6.6 21.7 16.5 22.4 9.5 25.0 Mazzaella flacc/da 11.4 8.2 31.8 13.1 32.2 16.7 13.4 10.0 22.2 Gastroc/onium suba rticulat ur 13.3 10.5 17.2 9.0 19.3 12.2 25.4 14.9 18.8 Phy/lospadixspp.

14.2 16.7 10.1 12.2 15.6 17.3 15.6 18.7 13.9 Egregia menziesii 3.4 6.6 9.7 9.9 20.4 21.5 7.5 9.1 10.2 coralline crust 9.3 6.6 10.8 6.1 7.2 6.3 4.4 4.1 8.0 Cryptopleura violacea 2.7 2.5 7.4 8.2 9.1 8.3 12.2 14.3 7.8 Chondracanthus cana/iculatus 7.7 6.0 4.2 3.9 5.1 4.8 10.8 6.4 7.0 Endoc/adia muricata 4.9 8.1 3.6 6.4 6.7 12.3 4.4 9.7 4.9 Ge/idiurn coulteri 3.9 5.8 6.2 7.4 5.6 6.0 3.3 3.0 4.7 Mastocarpus papil/atus 2.6 4.0 7.0 6.0 5.7 5.4 3.3 3.3 4.7 Mazzaella aff/nis 4.2 6.5 4.1 6.8 1.6 2.6 3.3 4.6 3.3 Smithora naiadum 3.4 6.8 6.3 7.9 2.7 4.2 3.1 Coral/ina vancouveriensis 4.5 3.5 4.3 6.3 1.9 5.4 1.0 1.5 3.0 Mastocarpusjlardinii 1.9 2.9 1.4 2.6 0.5 0.9 2.2 3.8 1.5 juv. articulated coralline algae 2.2 4.5 2.3 2.5 0.8 2.0 0.4 0.7 1.4

,Pr/onitis spp.

1.0 2.4 1.0 1.5 0.6 1.2 2.3 2.6 1.2 Mazzaella splendens 1.9 1.5 1.6 3.5 0.9 Calliarthron/Bossiella spp.-complex 0.4 0.7 0.3 0.8 0.3 0.7 1.5 2.1 0.7 Mazzaella oregona

<0.1

<0.1 0.9 1.4 0.6 0.9 0.1 0.3 0.4 Coral//na ohilensis

<0.1

<0.1 1.5 3.0 0.4 Callithamnion pikeanumn

<0.1

<0.1 0.2 0.5 1.0 1.9 0.3 Ulva spp.

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 1.1 3.5 0.3 Microcladia coulteri 0.1 0.4

<0.1 0.2 0.6 0.9 0.2 Grateloupia californ/ca 0.6 1.0

<0.1

<0.1 0.1 Sarcodiotheca gaudichiaudii

<0.1

<0.1 0.1 0.4 0.3 0.7 0.1 Halymenia/Schizyrnenia spp.-complex 0.4 0.9

<0.1

<0.1 0.1 Me/obesia med/ocr/s

<0.1

<0.1

<0.1

<0.1 0.3 0.8

<0.1 Cryptosiphonia wood/ii-0.3 1.1

<0.1

<0.1

<0.1 Ge/id/urn pus/i/lurn 0.1 0.3

<0.1

<0.1

<0.1

<0.1 0.1 0.4

<0.1 Osmundea spp.

0.2 0.5

<0.1 Colpomenia spp.

0.1 0.4

<0.1 filamentous red algae complex 0.1 0.4

<0.1 C/ado phora spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2

<0.1 Porphyra spp.

<0.1

<0.1

<0.1

<0.1

<0.1 0.2

<0.1 Chondracanthus corymbiferus

<0.1 0.2

<0.1

<0.1

<0.1 Mazzae/la leptorhynchos

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Microcladia/borealis

<0.1

<0.1

<0.1 Callithamnion spp.IPleonospor, spp.

<0.1

<0.1

<0.1 Laminariales

<0.1

<0.1

<0.1 Leathesia difformis

<0.1

<0.1

<0.1 (table continued)

W E!SLO2015-05 C-11

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C5 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 1+0.3m (4+ 1).

survey

  • 176.

ill 178,

1 79,

Survey Date...

13-Jan-14 :*,,....11-Jun-14 9-Jul-4 10-Oct-14 Std.

Std.

°std.

Std.

Annual

,Taxon

,Mean, Dev,..

Mean Dev. ]Mean, Dev.II Mean~t DeV.

Mean Invertebrate Counts Tetraclita rubescens Chlorostorna funebra/is Pa gurus spp.

Chlorostomna brunnea Ep/actis prolifera Fissure/Ia volcano Anthopleura elegantissima Lottia scutum Loftia scab~ra Strongy/ocentrotus purpuratus Loft/a pelta Pachygrapsus crassipes Lottia limnatula Ocinebrina spp.

Leptaster/as spp.

Nemertea Nutta//ina ca//fornica Serpulorbis squamigerus Pugeft/ia spp.

Mopalia spp.

Mitra /dae Serpulidae Pisaster/Henricia spp. (juv.)

Barleela spp.

Cirratulidae/Terebellidae Lottiidae Lissothuria nutriens A//a spp.

Lirobittiumn spp.

Lacuna spp.

Ischnochitonidae Sipuncula Acmaea rn/ta Cyanop/ax s pp.

Crep/dula spp.

Loft/a instabi/is Epitonium/Opalia spp.

Petrolist hes spp.

Pseudomelatoma torosa.

Pelecypoda boring Homnolo. lur/dum/LLirularia succincta 42.4 53.0 24.6 20.4 9.0 10.2 5.4 5.9 4.0 4.5 7.2 4.5 4.2 4.1 0.6 1.3 2.0 2.0 1.4 2.6 1.2 1.3 2.0 2.0 1.6 1.9 0.6 0.8 1.0 1.0 1.0 1.4 0.8 1.8 0.2 0.4 0.4 0.5 0.4 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 57.0 108.9 2.4 2.8 4.6 3.6 2.0 1.6 3.0 6.2 2.2 1.9 1.6 1.1 4.2 2.4 3.0 5.7 0.8 1.1 1.2 1.6 1.4 2.6 1.0 1.2 0.2 0.4 0.4 0.9 0.6 0.9 0.4 0.5 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 71.2 95.2 0.6

.0.9 1.8 0.8 3.2 2.6 3.4 7.1 1.6 1.1 1.6 2.1 1.8 1.9 2.6 3.8 1.0 1.0 1.2 1.6 1.6 1.3 0.4 0.9 0.8 1.1 1.0 1.0 0.6 0.9 0.4 0.5 0.2 0.4 0.4 0.5 0.6 0.9 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 58.4 109.6 0.6 1.3 1.4 1,1 4.8 4.9 4.8 9.1 4.0 4.0 2.2 2.8 2.0 1.6 1.4 1.9 1.0 1.2 0.8 0.8 0.4 0.9 0.4 0.9 0.4 0.5 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 57.3 7.1 4.2 3.9 3.8 3.8 2.4 2.2 1.8 1.2 1.2 1.2 1.0 0.8 0.6 0.6 0.4 0.3 0.3 0.3 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued) a-- ESLO2015-05 C-12

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C5 (continued). Intertidal algae, sessile invertebrates, and. substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC l+0.3m (4+1).

Suve

..i

.. 177

  • 1" 78 ;
179 S..

"'Survey Date 13-Jan-14 11-1un14

.o9-JulM4

... 10-Oct-14' Std.'

Std

.Std..

std.

AnnUal

!;Taxon."...

Mean

,,Dev.

Mean:

Dev.

Mean*

Dev,.

Mean...

Dev.

,Mean Invertebrate Cover Pistaspp.

2.9 5.4 2.8 4.0 1.2 2.1 5.6 11.7 3.1 tunicates, compound/social 1.8 3.9 0.5 1.5 2.1 2.9 3.7 7.5 2.0 Phragrnatopoma californica 1.2 2.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.3 Porifera (encrusting) 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Chthanialus fissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Salmacina tribranchiata

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Substrate Cover rock 3.7 3.7 6.7 3.5 4.0 5.3 4.0 2.7 4.6 sand (shell gravel) 0.6 1.0 0.4 0.9 0.3 1.1 4.7 12.8 1.5 cobble

<0.1

<0.1

<0.1

<0.1

<0.1 a

' ESLO2015_05C-3 C-13

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C6. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC l+0.9in (4+3).

"Survey Date 26-Feb144 11-Jun-14,,

25-Jul-4 23-Dec-14

  • Std.

Std.

Std,...

. Std.

Annual Taxon "

Mean Dev.

'Mean Dev.

"Mean

Dev.

Meani DeV.,

Mean Algae Cover Endocladia muricata non-coralline crust Mastocarpus papillatus Mazzaella flaccida coralline crust Calliarthron/Bossiella spp.-complex Phyllospadix spp.

Gelidium coulteri juv. articulated coralline algae Corallina vancouveriensis Mazzaella leptorhynchos Silvetia compressa Gelidium pusillum Prionitis spp.

Callithamnion pikeanunm Mazzaella affinis Chondracanthus corymbiferus Mazzaella ore gona Mastocarpus jardinii Pterosiphonia dendroidea Cryptosiphonia woodii Porphyra spp.

Cladophora spp.

Chondracanthus canaliculatus Gastroclonium subarticulatum filamentous red algae complex Invertebrate Counts Chlorostoma funebralis Ant hopleura elegantissima Lottia scabra Pa gurus spp.

Lottia limnatula Acanthinucella spp.

Lottia scutum Ocinebrina spp.

Lottia pelta Pachygrapsus crassipes Fissurella volcano Hemigrapsus nudus Cyanoplax spp.

Mopalia spp.

Tetraclita rubescens Haliotis spp.

Nuttallina califomnica 30.9 28.8 7.0 1.1 2.0 1.0 0.8 0.3 0.6 0.8

<0.1

<0.1 0.5 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 210.6 442.6 26.2 56.4 2.6 3.4 1.6 0.8 0.6 1.0 0.6 0.6 0.2 0.2 20.6 14.9 7.3 3.0 3.0 3.1 2.0 0.5 1.7 2.6

<0.1

<0.1 0.7 0.3 1.3 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 147.2 509.9 35.9 59.6 1.7 2.1 2.6 0.4 0.9 1.4 1.3 0.9 0.4 0.6 32.8 21.2 13.9 4.7 3.1 0.6 0.8 0.6 1.1

<0.1 0.1 0.4

<0.1

<0.1 0.4 0.1

<0.1

<0.1

<0.1

<0.1 273.4 266.4 24.8 10.0 2.2 1.0 2.4 1.4 0.6 1.4 0.6 0.6 0.6 0.2 0.2 15.5 12.0 12.5 6.4 4.9 2.0 1.7 1.0 2.6 0.2 0.3 1.3 0.2 0.2 1.1 0.4 0.2

<0.1

<0.1

<0.1 123.7 277.5 39.8 4.8 2.5 2.5 0.5 0.9 1.3 1.3 0.9 0.9 0.4 0.6 38.3 22.8 19.0 12.4 0.9 0.8 1.0 2.2

<0.1 0.5 1.2 0.3

<0.1 0.3

<0.1

<0.1 0.3 0.2

<0.1

<0.1

<0.1

<0.1 24.7 11.6 12.1 10.2 2.1 2.4 2.2 2.2

<0.1 1.3 1.4 0.9

<0.1 0.8 0.2

<0.1 0.9 0.7

<0.1 0.2

<0.1

<0.1 24.2 23.3 31.3 16.8 3.3 4.7 0.5 0.8 2.2 3.8 1.0 3.1 0.6 1.2 0.5 1.1 0.6 1.5 0.3 0.7

<0,1

<0.1

<0.1 0.2

<0,1

<0.1 384.6 146.3 255,8 275.2 32.4 47.6 38.6 13.9 0.4 0.9 2.0 1.6 1.2 1.3 2.0 1.9 1,4 2.1 0.2 0.4 1,0 1.4 0,4 0.5 0.2 0.4 0,2 0.4 0,8 1.8 0.2 0.6 0.6 0.5 31.5 26.0 10.8 4.7 2.0 0.8 0.8 0.7 0.6 0.5 0.3 0.2 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 358.2 336.3 37.2 28.7 2.9 2.0 1.5 1.4 0.9 0.9 0.7 0.4 0.4 0.2 0.2 0.2 0.2 564 380 65 9

6 0

0

<0

<0 t.0 274.4

].2 460.7 5.4 99.8

.8 12.3

.2 6.3

.4 2.1

].8 0.8

.2 0.8

.0 1.0

).8 0.4

.0 2.2

.1

<0.1

.2 0.4 (table continued)

  1. LWESLO2015-05 01 C-14

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C6 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 1+0.9m (4+3).

Survey:

176

,177 175 179..

1.....

" Survey Date-26-Feb-14 11-Ju~n-14.

... 25-J1ul-14... '

'23:Dec.i4.

,Std.

Std.

St.t.

nna

Taxon, Mean
  • Dev.,
Mean, Dev.

Mean 0 ev...

Mean Dev.

, Mean.

Invertebrate Counts (continued)

Ophiothrix spiculata 0.4 0.9 0.1 Cirratulidae/Terebellidae 0.2 0.4

<0.1 Nereididae 0.2 0.4

<0.1 Strongylocent'rotus purpuratus 0.2 0.4

<0.1 Serpulidae 0.2 0.4

<0.1 Lottiidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 lschnochitonidae

<0.1

<0.1

<0.1 Littorinaspp.

<0.1

<0.1

<0.1 Polychaeta

<0.1

<0.1

<0.1 Pollicipes polymerus

<0.1

<0.1

<0.1 Sipuncula

<0.1

<0.1

<0.1 Barleeiaspp.

<0.1

<0.1

<0.1 Invertebrate Cover Phragmatopoma califomnia 4.2 4.6 1.5 2.5 1.0 2.0 7,4 8.1 3.5 Chthamalus fissus 1.0 1.6 0.6 1.2 0.6 1.2 1,3 1.7 0.9 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Haliclona spp.

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1 Substrate Cover rock 12.5 7.9 22.1 11.1 20.4 15.2 15.5 11.7 17.6 sand (shell gravel) 5.3 8.5 0.6 1.0 0.4 1.1 8.6 8.7 3.7 cobble 2.5 5.1 2.3 3.5 3.9 6.2 4.6 8.0 3.3

'I ESLO2015_05 C-15

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C7. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 2+0.3m (5+1).

Survey 176 177 178 179 Survey Date 13-Jan-14 12-Jun-14 9-Jul-14 24-Oct-14 Std.

Std.

Std.

Std.

Annual Taxon Mean.

Dev.

Mean 0ev.

Mean, 0ev.

Mean Dev.

Mean Algae Cover non-coralline crust Mazzaella flaccida Corallina vancouveriensis Phyllospadix spp.

coralline crust Endocladia muricata Gelidium coulteri Gastroclonium subarticulatum Egregia nmenziesii Crypto pleura violacea Calliarthron/Bossiella spp.-complex Prionitis spp.

Chondracanthus canaliculatus Mastocarpus papillatus juv. articulated coral! ne algae Mazzaella affinis Mastocarpus jardinfi Mazzaella ore gona Smithora naiadum Osmundea spp.

Cryptosiphonia woodii Mazzaella splendens Chondracanthus corymbiferus Gelidium pusilurn Corallina chilensis Cal/ithamnion pikeanum Microcladia coulteri Laminaria setchellii Mazzaella leptorhynchos Chiorophyta (filamentous)

Microcladia borealis Porphyra spp.

Acrosiphonia spp.

Pterosiphonia dendroidea Cladophora spp.

Ulva spp.

Melobesia rnediocris Sarcodiotheca gaudichaudji Ca//ophyllis spp.

Laminariales 38.7 11.6 8.1 6.6 9.9 11.9 6.3 12.6 9.3 5.1 9.1 11.1 5.2 5.5 3.5 7.0 1.9 4.1 3.0 4.1 3.2 6.0 2.2 3.5 5.8 6.7 2.0 2.7 1.3 2.0 1.1 2.0 0.8 1.6

<0.1 0.2

<0.1

<0.1 0.1 0.4 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 18.4 9.5 18.2 10.3 12.5 14.6 9.9 19.5 13.6 10.1 10.0 12.9 10.6 5.9 9.9 11.4 3.7 7.2 4.2 5.7 2.2 4.2 3.0 5.1 1.1 1.6 5.0 3.7 2.6 2.0 1.2 2.3 1.7 1.8 1.4 2.4 1.2 2.1 1.0 1.3 0.6 1.2 1.2 1.4 0.4 1.1

<0.1

<0.1 0.2 0.5

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 0.1 0.4 0.1 0.4

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 21.5 13.9 24.0 12.6 6.9 11.9 9.7 21.7 7.1 6.2 8.8 12.4 11.4 12.0 9.1 10.8 10.4 19.5 7.6 8.5 3.1 4.5 4.2 7.4 3.1 3.2 2.1 3.8 3.0 2.8 1.3 2.7 0.3 0.5 1.0 0.9 1.1 2.1 0.3 0.6 0.6 1.3

<0.1

<0.1 0.1 0.4 0.3 0.9 0.3 0.9 0.3 0.6

<0.1

<0.1 0.2 0.7 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 19.6 7.6 6.3 5.5 12.7 10.8 14.0 26.4 7.0 4.6 6.7 9.3 6.0 5.3 7.8 9.8 7.9 13.1 7.5 5.1 5.8 6.7 4.5 5.8 3.9 4.7 2.2 4.5 0.1 0.4 1.0 2.0 1.4 2.3

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.5 0.9 0.2 0.7 0.6 1.0

<0.1

<0.1 0.3 1.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 24.5 14.1 10.5 10.0 9.3 8.7 8.3 7.6 6.0 5.6 3.6 3.5 3.5 2.8 1.7 1.2 1.1 0.6 0.6 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued) a*I' ESLO2015-05 C-16

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C7 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 2+0.3m (5+1).

Survey 176

[ 177 178 179 Survey Date 13-Jan-14 12-Jun-14 9-JuM-4 24-Oct-14 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev.

Mean 0ev.

Mean 0ev.

Mean 0ev.

Mean Invertebrate Counts Chlorostoma funebralis Strongylocentrotus purpuratus Anthopleura elegantissirna Teltracla rub~escens Pa gurus spp.

Fissurella volcano Lottia scabra Lottia scutum Nullallina californica Lotlia pelta Chioro stoma brunnea Nemertea Pachygrapsus crassipes Epiaclis pro/ifera Lot/ia limatula Leptasterias spp.

Ocinebjrina spp.

Mopalia spp.

Pugettia spp.

Nereididae Ophiothrix spiculala Tonicelia lineata Hemigrapsus nudus Serpulidae Ophiaclis simplex Ha//otis spp.

Lottiidae Heplacarpus spp.

A/ia spp.

Ischnochitonidae Lirobittium spp.

Amphissa spp.

Sipuncula Grapsidae Acmaea min/ra Pycnogonida Phidiana hi/toni Lacuna spp.

Cirratulidae/Terebellidae Homnolo. luridum/Lirularia succin cta 93.6 43.2 17.6 14.1 14.6 17.4 36.8 40.2 16.2 7.0 4.8 4.4 0.4 0.9 1.4 2.2 0.4 0.9 1.2 2.7 1.0 1.0 0.2 0.4 1.0 0.7 0.4 0.5 0.6 0.9 0.2 0.4

<0.1

<0.1 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 42.0 24.4 14.4 2.0 6.8 3.4 0.8 2.6 0.6 1.6 1.2 1.4

<0.1 0.4 0.4 0.2 0.2 0.4 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 68.6 13.7 18.7 3.5 5.4 1.7 1.1 2.7 0.9

.0.9 0.8 1.1

<0.1 0.5 0.9 0.4 0.4 0.9 0.4 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.6 6.2 19.8 12.4 19.0 19.8 5.6 12.0 6.0 5.9 2.0 1.7 2.4 3.3 2.0 2.3 1.4 1.5 1.4 1.1 1.2 2.7 0.2 0.4 1.0 0.7 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 67.8 87.0 10.6 7.2 15.8 11.2 5.8 11.4 15.4 8.9 12.2 7.8 5.6 7.3 2.4 1.8 2.0 3.5 1.6 1.5 1.2 2.7 1.8 1.8 0.2 0.4 1.0 1.4 0.8 1.8 1.0 1.2 0.2 0.4 0.4 0.5 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 53.0 18.1 16.0 12.6 11.1 5.6 2.3 1.8 1.4 1.3 1.2 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table conlinued)

ES0150 C-17

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C7 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 2+0.3m (5+1).

Survey 176 177 178 179 Survey Date 13-Jan-14 12-Jun-14 9-Jul-4 24-Oct-14 Std.

Std.,

Std.

Std.

Annual Taxon Mean Dev.

Mean 0ev.

Mean Dev.

Mean Dev.

Mean Invertebrate Cover Pistaspp.

0.2 0.7

<0.1

<0.1

<0.1

<0.1 3.0 7.9 0.8 Phragmatopoma califomica 0.1 0.4 0.1 0.4 0.3 0.9 1.2 3.1 0.4 tunicates, compound/social

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.7

<0.1 Dodecaceria fewkesi 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1 Chthamalus fissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Salmacina tribranchiata

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Haliclonaspp.

<0.1

<0.1

<0.1 Substrate Cover rock 4.9 4.5 9.9 5.4 5.8 3.6 4.5 4.0 6.3 sand (shell gravel) 1.2 1.9 1.1 3.1 0.8 1.4 3.7 6.1 1.7 cobble

<0.1 0.2

<0.1

<0.1 0.3 0.6

<0.1 aI'wESLO2015-05 C-1 8

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C8. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 2+0.9mn (5+3).

Survey 176 T

177 178 179 Survey Date 13-Jan-14

,12-Jun-14 23-Jul-4 24-Oct-14 Std. IStd.

Std.

Std.

Annual Taxon Mean Dev. 4 Mean

.0ev.

Mean 0ev. 4 Mean Dev.

Mean Algae Cover Endocladia muricata 40.0 11.9 39.0 9.6 35.2 14.2 39.7 17.8 38.5 non-coralline crust 25.7 15.3 13.1 9.8 14.6 13.2 18.2 8.0 17.9 Mastocarpuspapillatus 6.1 4.7 15.1 8.8 22.0 11.0 15.3 5.3 14.6 Mazzaella flaccida

<0.1

<0.1 6.3 9.2 6.7 8.6 4.9 6.8 4.5 Silvetia compressa 3.4 5.7 2.0 3.9 2.2 4.3 2.0 3.3 2.4 Fucus gardneri 0.7 2.2 1.1 3.5 0.7 2.2 0.6 1.3 0.8 Cladophora spp.

<0.1

<0.1 0.2 0.8 1.0 0.5 0.8 0.3 Gelidium coulteri

<0.1

<0.1 0.3 0.9 0.3 0.8 0.2 Prionitis spp.

0.3 0.9

<0.1

<0.1 0.1 0.4 0.2 0.5 0.2 coralline cruSt

<0.1 0.2 0.1 0.4

<0.1 0.3 0.6 0.1 Mazzaella affinis

<0.1

<0.1 0.1 0.3

<0.1 0.2 0.3 0.6 0.1 Porphyraspp.

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1 Gelidiumpusillum

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 Mazzaella ore gona

<0.1 0.2

<0.1 Chondracanthus canaliculatus

<0.1

<0.1

<0.1

<0.1

<0.1 juv. articulated coralline algae

<0.1

<0.1

<0.1

<0.1

<0.1 Hesperophycus califomicus

<0.1

<0.1

<0.1

<0.1

<0.1 Corallina vancouveriensis

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Mazzaella leptorhynchos

<0.1

<0.1

<0.1 Ulva spp.

<0.1

<0.1

<0.1 Cryptosiphonia woodii-

<0.1

<0.1

<0.1 Gastroclonium subarticulatum

<0.1

<0.1

<0.1 Microcladia coulteri

<0.1

<0.1

<0.1 Cryptopleura violacea

<0.1

<0.1

<0.1 filamentous red algae complex

<0.1

<0.1

<0.1 Invertebrate Counts Chlorostomafunebralis 113.6 74.5 125.0 32.0 122.0 85.5 207.8 210.6 142.1 Anthopleura elegantissima 112.8 73.3 112.0 107.1 56.0 44.7 66.4 42.2 86.8 Lottia scabra.8.8 5.4 7.0 4.6 23.4 21.6 51.2 52.9 22.6 Pagurusspp.

8.2 12.7 6.0 6.1 1.8 2.0 11.6 12.1 6.9 Lottia lirnatula 0.4 0.5 1.4 2.1 1.4 2.2 2.0 2.8 1.3 Lottia pelta 1.2 1.1 0.2 0.4 0.2 0.4 2.4 3.2 1.0 Pachygrapsus crassipes 1.2 0.8 1.6 1.5 0.8 1.1 0.9 Acanthinucella spp.

0.6 0.9 0.8 0.8 0.6 0.5 0.2 0.4 0.6 Lottia scutum 0.8 1.1 0.4 0.9 0.4 0.5 0.4 0.5 0.5 Cyanoplaxspp.

0.6 0.9

<0.1

<0.1 0.4 0.9 0.8 1.3 0.5 Lottiidae

<0.1

<0.1 1.4 3.1

<0.1

<0.1

<0.1

-0.4 Ocinebrina spp.

0.2 0.4 1.0 1.0 0.3 Pollicipes polymerus 0.6 1.3

<0.1

<0.1 0.2 Nemertea 0.2 0.4 0.2 0.4 0.1 Cirratulidae/Terebellidae

<0.1

<0.1 0.2 0.4

<0.1 Littorinaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued)

'L*

ESLO2O1 5-05 C-1 9

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C8 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 2+0.9m (5+3).

Survey 176:

177 178 "179 i

Survey Date.

13-Jan-14:

, 12-Jun-14,'

23-Jul-14,:

  • , 24-Oct-14,,.

',1,

,Std;...

Std..

Std.

,,Std.

Annual Taxon Mean

,Dev.

,Mean*

Dev.,,Mean...

0ev. ',Mean 0ev.'

Mean Invertebrate Counts (continued)

Epitonium/Opelia spp.

<0.1

<0.1

<0.1 Idotea spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Lottia gigentea

<0.1

<0.1

<0.1 Nereididae

<0.1

<0.1

<0.1 lschnochitonidae

<0.1

<0.1

<0.1 Invertebrate Cover Phragmnatopoma califomica 2.4 2.4 0.9 1.4 0.4 0.9 2.1 2.0 1.4 Chthamalus fissus

<0.1 0.2 0.1 0.4

<0.1

<0.1 0.2 0.7 0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 Substrate Cover rock 24.7 11.9 29.9 16.4 33.2 18.8 17.7 11.1 26.4 sand (shell gravel) 4.4 8.5 0.8 1.5 0.8 1.6 5.6 11.4 2.9 cobble

<0.1

<0.1 0.6 2.0 0.7 2.0 0.1 0.4 0.4 a'*L ESLO2015-05 C2 C-20

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C9. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 3+0.3m (6+1).

Surve 176 17..

178 1,79, SurveyDate 26-Feb-14 10-Jun-14,

23-Jul-4 26-Nov-14,

.,Taxon 4

o..

,Mean Dev.

,Mean, Dev,.

Mean, Dev.'
Mean, 0,ev.

.Mean Algae Cover non-coralline crust Mazzaella flaccida Gastroc/onium subarticulatum coralline crust Phyllospadix spp.

Cryptopleura violacea Gelidium coulteri Calliarthron/Bossiella spp.-complex Mastocarp us jard/nfi juv. articulated coralline algae Mastocarpus papi/lat us Chondracanthus canaliculatus Prionitis spp.

Mazzael/a ore gona Coral/ina vancouveriensis Smithora naiadum Mazzaella affinis Endocladie muricata Ge/idiurn pusil/urn filamentous red algae complex Microcladia coulteri Mazzaella splendens Sarcodiotheca gaudichaudii Callithamnion pikeanurn Chondracanthus coyrnmbiferus Cryptosiphonia woodii Egregia menziesii Mazzaella leptorhynchos Osmundea spp.

Pterosiphonia dendroidea Larninaria setchelili Halyrnenia/Schizyrnenia spp.-complex Cladophora spp.

Melobesia mediocris Acrosiphonia spp.

U/va spp.

Coral/ina chilensis Chiorophyta (filamentous)

Cystoseira osmundacea Microcladia borealis Leathesia difformis Farlowia/Pikea s pp.-complex 34.3 9.5 21.4 20.0 13.9 10.7 11.6 10.1 5.8 10.1 4.6 6.8 4.1 4.1 3.1 4.7 3.2 3.2 2.6 2.3 3.5 4.6 3.7 4.5 1.0 1.2 0.4 0.7 1.0 1.3 1.0 1.5 1.3 2.8 0.8 1.0 0.1 0.3

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 23.6 40.5 20.4 7.0 7.4 7.6 6.7 5.3 2.6

<0.1 2.7 0.7 1.2 5.6 0.1 1.6 1.3 0.1

<0.1 1.2

<0.1 0.8 0.1 0.2 0.1 0.3

<0.1

<0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1 5.2 33.5 23.6 8.3 12.0 7.8 6.1 9.8 3.4

<0.1 4.2 1.5 1.5 7.0 0.3 3.1 3.1 0.4

<0.1 3.1

<0.1 1.8 0.4 0.7 0.4 0.9 0.2 0.2 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1 25.2 9.0 31.2 24.1 21.4 21.5 10.8 10.2 9.9 16.9 8.1 6.6 9.0 8.5 2.6 4.7 2.2 2.1 0.1 0.3 1.5 1.9 1.9 2.0 1.8 2.5 0.3 0.5

<0.1 0.2 3.7 5.6 1.7 4.8

<0.1 0.2 0.7 1.2

<0.1 0.2 0.9 2.2 0.3 0.8 0.4 0.9 0.1 0.4 0.2 0.7

<0.1 0.2

<0.1 0.2 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 32.2 17.4 15.4 17.2 9.0 3.6 2.8 4.7 1.5 6.0 0.8 1.0 2.6 4.6

<0.1 0.3 0.8 0.3

<0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.1 19.4 11.5 14.8 14.3 4:5 2.6 6.9 1.8 7.6 1.5 1.4 3.7 4.1

<0.1 1.1 2.6 0.6

<0.1 0.4 0.4 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 28.8 27.6 17.8 11.7 8.0 6.0 5.6 3.9 2.4 2.2 2.1 1.8 1.7 1.6 1.4 1.3 1.1 0.6 0.5 0.4 0.2 0.2 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued)

ES LO2015-05 C2 C-21

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C9 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Station FC 3+0.3m (6+1).

Survey 176 177 178 179 Survey Date 26-Feb-14 10-Jun-14 23-Jul-4 26-Nov-14 Std. IStd.

Std.

Std.

Annual TaXon Mean Dev.

Mean Dev.

  • Mean Dev.

-Mean Dev.

Mean Invertebrate Counts Strongylocentrotus purpuratus Chlorostoma funebralis Tetraclita rubescens Pa gurus spp.

Anthopleura elegantissima Fissurella volcano Chiorostoma b~runnea Pachygrapsus crassipes Lottia scutum Ocinebrina spp.

Lottia pelta Leptasterias spp.

Nemertea Epiactis prolifera Lottia limatula Serpulidae Mopalia spp.

Lottia scabra Pugettia spp.

Diodora spp.

Serpulorbis squamigerus Pseudomelatoma torosa Ophiothrix spiculata Sipuncula Alia spp.

Tonicella lineata Nereididae Octopus spp.

Nuttallina californica Romaleon antennarius Patiria miniata Stenoplax spp.

Rornaleon jordani Haliotis spp.

Lottiidae Acrnaea mitra Homolo. luridum/Lirularia succincta Lacuna spp.

Crepidula spp.

Ischnochitonidae Grapsidae Hermnissenda crassicomis Epitonium/Opalia spp.

Isoioda 48.0 101.3 51.2 48.3 30.4 21.9 7.4 7.1 5.8 2.9 2.8 1.9 0.6 0.9 1.2 1.1 0.4 0.5 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 31.4 66.4 1.8 1.8 6.6 7.5 2.4 1.5 4.2 3.4 1.8 1.8 1.4 2.1 0.6 0.5 1.0 1.4 0.4 0.9 0.2 0.4 0.6 0.9 0.2 0.4 0.2 0.4 0.2 0.4 0.4 0.5 0.4 0.9 0.2 0.4

<0.1

<0.1 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

-<0.1 21.2 44.7 2.4 2.3 4.8 4.8 14.8 12.6 2.6 1.1 4.8 2.0 2.0 2.4 2.0 1.9 0.8 1.3 1.0 1.4 0.8 1.8 0.8 0.8 0.4 0.5 0.8 1.3 0.4 0.5 0.2 0.4

<0.1

<0.1 0.4 0.9 0.2 0.4 0.4 0.9 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 38.4 76.6 72.8 84.5 8.8 6.2 11.0 8.6 4.8 3.4 4.0 1.9 1.4 2.2 0.6 0.9 0.4 0.5 0.8 1.3 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.8 1.3 0.4 0.5 0.2 0.4

<0.1

<0.1 0.4 0.5

<0.1

<0.1

<0.1

<0.1 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 34.8 32.1 12.7 8.9 4.4 3.4 1.4 1.1 0.6 0.6 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued)

    • 'w ESLO2015-05 C-22

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C9 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for Station FC 3+0.3m (6+ 1).

-Survey, 1 76,i 177

.178 179*

,,aSurvey Dae 26,-Feb-14 10-Jun-14.

23-Jul-4

'26.Nov214, Std.

Std..

Std.

Std.

Annual Taxon,,:,

1 Mean!

'Dev.

Mean Dev.

Mean' Dev.

,Mean "Dev.

Mean Invertebrate Counts (continued)

Heptacarpusspp.

<0.1

<0.1

<0.1 Aeolidia papillosa

<0.1

<0.1

<0.1 Lissothuria nut riens

<0.1

<0.1

<0.1 Invertebrate Cover Pista spp.

1.7 4.0 4.7 11.0 1.9 5.9 4.2 7.7 3.1 Phragmatopoma califomica 4.6 9.0 2.6 6.3 1.3 2.6 2.6 8.3 2.8 tunicates, compound/social

<0.1

<0.1

<0.1

<0.1 0.6 1.4

<0.1

<0.1 0.2 Chthamalus fissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Dodecaceria fewkesi

<0.1

<0.1

<0.1 Substrate Cover rock 1.2 0.9 7.4 9.0 5.3 3.9 4.0 3.6 4.5 sand (shell gravel) 0.3 0.6 1.2 2.1 1.3 2.2 1.0 1.2 1.0 cobble 0.1 0.4

<0.1

<0.1

<0.1 0.2 0.3 0.8 0.1 WESLO2015-05 C2 C-23

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C10. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 3+0.9m (6+3).

Survey 176 177 178 179 Survey Date 26-Feb-14 10-Jun-14 23-Jul-4 26-Nov-1'4 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev. j Mean

,Dev.*

Mean Dev.

Mean, Dev.

Mean Algae Cover Endocladiamuricata 34.8 11.3 39.0 13.1 26.2 15.0 25.0 7.1 31.3 non-coralline crust 27.2 14.6 18.6 8.7 22.0 10.1 34.2 7.3 25.5 Mastocarpuspapillatus 15.4 8.2 26.0 16.3 35.8 13.8 19.1 11.0 24.1 Mazzaellafleccida 5.5 5.5 14.0 8.9 18.9 11.7 6.6 3.8 11.2 Gelidium coulteri 3.0 3.6 2.5 5.3 5.3 9.5 1.2 2.5 3.0 Silvetia compressa 3.7 5.9 2.8 4.4 2.2 3.1 3.2 4.7 3.0 coralline crust 0.3 0.8 0.9 1.5 0.4 0.9 3.3 1.8 1.3 Gelidiumpusillum 2.2 1.4 0.3 1.1

<0.1

<0.1 0.1 0.3 0.7 Mastocarpusjardinfi 0.7 1.0 0.1 0.3 0.3 0.9 0.5 0.7 0.4 Cryptosiphionia woodii 0.6 1.1 0.7 1.8 013 0.9

<0.1

<0.1

.0.4 Prionitisspp.

<0.1

<0.1 0.1 0.4 0.9 2.1 0.1 0.3 0.3 Mazzaella affinis

<0.1

<0.1

<0.1

<0.1 0.3 0.5 0.8 2.2 0.3 Mazzae lia ore gona 0.1 0.4 0.2 0.3 0.4 0.6 0.2 juv. articulated coralline algae

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 0.4 0.9 0.1 Corallina vancouveriensis

<0.1

<0.1

<0.1

<0.1I 0.4 0.7 0.1 Chondracanthius canaliculatus 0.2 0.5

<0.1

<0.1

<0.1

<0.1 0.2 0.5 0.1 Cladophora spp.

<0.1

<0.1

<0.1

<0.1 0.3 0.9

<0.1

<0.1 Porphyra spp.

0.2 0.7

<0.1 Mazzaelle leptorhynchos

<0.1 0.2

.<0.1

<0.1

<0.1

<0.1

<0.1 Calliarthron/Bossiella spp.-cornplex

<0.1

<0.1

<0.1

<0.1

<0.1 Ulvaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Callithermnion pikeanum

<0.1

<0.1

<0.1 Gastroclonium subarticulatum

<0.1

<0.1

<0.1 Sarcodiotheca gaudichaudii

<0.1

<0.1

<0.1 Cryptopleura violacea

<0.1

<0.1

<0.1 Invertebrate Counts Chlorostomafunebralis 103.0 90.2 285.4 133.4 149.2 118.7 147.6 82.2 171.3 Pagurusspp.

5.6 6.2 2.4 1.9 13.2 9.3 17.0 12.4 9.6 Anthopleura elegantissirma 4.6 4.2 3.8 5.0 2.4 1.5 12.6 22.1 5.9 Lottie scabra 2.0 2.5 2.2 2.8 7.8 8.4 5.6 5.2 4.4 Pachygrepsus crassipes 0.2 0.4 1.2 1.3 2.2 1.9 0.6 0.5 1.1 Mopalia spp.

0.2 0.4 0.4 0.9 0.4 0.5 0.6

.0.9 0.4 Ocinebjrina spp.

0.4 0.5 0.4 0.5 0.8 0.4 0.4 Lottia pelte 0.2 0.4 0.2 0.4 0.4 0.5 0.6 0.9 0.4 Lottia scutum 1.2 2.7 0.2 0.4 0.4 Acenthinucella spp.

0.2 0.4 0.2 0.4 0.2 0.4 0.6 0.9 0.3 Cyanoplax spp.

0.6 1.3 0.4 0.9

<0.1

<0.1 0.3 Lottie limatula 0.2 0.4 0.2 0.4 0.4 0.5 0.2 Sipuncula 0.8 1.8 0.2 Nemertea 0.2 0.4 0.2 0.4 0.1 Cirratulidae/Terebellidae 0.2 0.4 0.2 0.4 0.1 Nuttallina califomnica 0.2 0.4

<0.1 Hemnigrapsus nudus 0.2 0.4

<0.1 Strongylocentrotus purpuratus 0.2 0.4

<0.1 (table continued)

'w ESLO2015-05 C-24

Appendix C - Intertidal Algae, Invertebrates and Substrates Table Cl0 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for Field's Cove Station FC 3+0.9m (6+3).

Survey 176 177 178 179 Survey Date 26-Feb-14 10-Jun-14 23-Jul-14 26-Nov-14 Std.

Std.

Std.

Std.

Annual Taxon *,.

  • ,Mean Dev.

Mean 0 ev.

Mean Dev.

Mean Dev.

Mean Invertebrate Counts (continued)

Pugettia spp.

0.2 0.4

<0.1 Lottiidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Lifttorinaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Lacuna spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Epitonium/Opalia spp.

<0.1

<0.1

<0.1

<0.1

<0.1

]schnochitonidae

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1 Invertebrate Cover Phragmatopomacalifomica 7.8 8.8 3.1 4.3 1.9 2.4 12.1 11.0 6.2 Chthamalus fissus 0.1 0.4 0.3 0.9

<0.1

<0.1 0.4 1.3 0.2 Spirorbidae

<0.1

<0.1

<0.1 Substrate Cover rock 10.0 11.9 17.0 13.3 12.0 11.8 8.5 6.0 11.9 sand (sheJi gravel) 2.3 4.3 0.3 0.6 1.1 2.0 0.6 1.7 1.1 cobble 0.1 0.4

<0.1 0.2 0.4 1.3 0.2 ESLO2O15-05 C-25

Appendix C - Intertidal Algae, Invertebrates and Substrates Table Cll. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 1+0.3m (7+1).

Survey 176 177 117811 79 Survey Date 12-Feb-14 13-Jun-14 25-Jul-14 25-Nov-14 Std.

Std.

Std. IStd.

Annual Taxon Mean 0ev.

Mean Dev. {Mean

Dev, Mean Dev.

Mean Algae Cover non-coralline crust filamentous red algae complex Cod/urn fragile subsp. californicum Mastocarpus papIllat us Ge/id/urn cou/teri coralline crust U/va spp.

Chondracanthius canaliculatus Prion/tis spp.

Endocladia muricata Mazzaella affinis Plerosiphonia dendro/dea Mastocarpus lard/nil Gel/diurn pus//lum Calliarthron/Bossie/la spp.-complex Corallina vancouveriensis Cryptopleura vio/acea Cladophora spp.

juv. articulated coralline algae Curmag/o/a andersonii Chiorophyta (filamentous)

Chondracanthus corymbiferus Co/pomenia spp.

Ca//ithamnion pikeanumn Gastroc/onium subarticulaatum Endarachne/Petalonia-complex Acrosiphonia spp.

Mazzaella leptorhynchos Sarcod/otheca gaudichaudii Halymenia/Schizymenia spp.-complex Invertebrate Counts Tetrac/ita rubescens Lottia scabra Pa gurus spp.

Strongy/ocentrotus purpuratus Fissure//a volcano Loft/a pe/ta Anthop/eura elegantiss/ma Pachygrapsus crassipes Loft/a i/matu/a Loft/a scutum Chl/orostorna funebra/is Ocinebrina spp.

Nutta/lina californica 42.7 17.3 6.6 6.2 5.1 6.7 0.3 0.6

<0.1

<0.1 1.7 1.4

<0.1

<0.1

<0.1 0.2

<0.1

<0.1 0.3 0.9

<0.1 0.2 0.7 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 468.6 150.8 127.0 57.2 66.8 29.5 7.6 3.8 13.8 3.8 10.2 2.4 4.4 2.7 1.4 2.2 4.4 2.1 2.6 0.9 2.0 3.9 3.4 3.4 0.6 0.9 39.0 6.2 6.2 4.5 2.0 1.6 1.5

<0.1 0.2 0.9 0.4 0.3 0.4 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 479.8 177.2 21.6 17.0 12.2 9.2 6.2 4.4 4.2 4.4 0.4 1.2 1.0 16.8 4.0 7.6 7.4 1.4 1.7 2.8 0.2 0.7 2.9 0.9 0.5 0.9 0.3 0.2 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 56.4 88.5 18.6 3.8 3.9 6.0 8.5 3.7 2.6 5.7 0.9 1.3 1.0 32.6 22.2 6.9 4.5 8.1 9.0 4.9 9.5 6.6 4.7 0.8 1.8 1.1 2.1 0.6 1.6 0.1 0.4 0.3 0.6 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 517.6 285.4 261.0 229.8 5.8 4.3 26.6 21.7 13.6 9.6 18.2 8.8 3.6 4.3 5.4 1.8 1.2 0.8 1.0 1.7 1.0 1.0 31.1 10.2 13.4 5.1 4.0 5.3 1.5 1.8 1.7 1.5 3.3 4.8

<0.1

<0.1 0.4 0.6 0.8 1.1

<0.1

<0.1 0.1 0.3 0.3 0.6

<0.1

<0.1 0.3 0.6 0.4 1.3

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 36.4 8.3 5.8 2.8 2.6 1.9 0.6 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0,1

<0.1

<0.1

<0.1

<0.1

<0.1 464.4 186.2 27.5 18.8 12.1 10.9 4.8 3.0 2.9 2.1 1.7 1.2 0.9 391.6 179.6 15.8 24.0 8.6 6.0 5.0 0.6 1.6 0.2 4.4 1.0 136.6 91.0 5.6 18.6 5.9 4.0 3.3 0.9 1.1 0.4 6.7 1.0 (table continued)

  • PEIEVESLO2015-05 C-26

Appendix C - Intertidal Algae, Invertebrates and Substrates Table Cll (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 1+0.3m (7+ 1).

Survey 176 177 178 179 Survey Date 12-Feb-14 13-Jun-14 25-Jul-14 25-Nov-14 Std.

Std.

Std.

Std.

Annual Taxon Mean 0ev.

Mean Dev.

Mean 0ev.

Mean 0ev.

Mean Invertebrate Counts (continued)

Ant hopleura xanthogrammica 0.8 0.8 0.4 0.5 0.6 0.5 0.2 0.4 0.5 Chloro stoma brunnea 1.6 2.6 0.4 0.5 0.5 Lottia gigantea 0.8 1.8 0.4 0.9 0.4 0.9 0.4 Serpulidae 1.2 1.6 0.3 Lottiidae

<0.1

<0.1

<0.1 0.8 1.3 0.2 Acanthinucella spp.

0.2 0.4 0.2 0.4 0.1 Patiria miniata 0.4 0.5 0.1 Pisaster ochraceus 0.4 0.9 0.1 Cyanoplaxspp,

<0.1

<0.1

<0.1

<0.1 0.2 0.4

<0.1

<0.1

<0.1 Epiactis prolifera 0.2 0.4

<0.1 Diodora spp.

0.2 0.4

<0.1 Mopalia spp.

0.2 0.4

<0.1 Serpulorbis squamigerus 0.2 0.4

<0.1 Strongylocentrotus franciscanus 0.2 0.4

<0.1 Pugettia spp.

0.2 0.4

<0.1 Mytilusspp,

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Littorinaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 lschnochitonidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Pelecypoda boring

<0.1

<0.1

<0.1 Heptacarpusspp.

<0.1

<0.1

<0.1 Barleeia spp.

<0.1

<0.1

<0.1 Homolo. luridum/Lirularia succincta

<0.1

<0.1

<0.1 Invertebrate Cover Chthamalus fissus 6.4 5.2 9.4 8.1 7.8 10.0 10.7 11.3 8.6 Phragmatopoma califomnica 6.6 4.2 1.5 1.5 0.6 0.7 3.2 1.5 3.0 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1 Substrate Cover rock 21.1 9.2 12.9 4.9 19.1 12.1 17.7 7.5 17.7 sand (shell gravel) 7.1 4.1 9.0 6.0 9.9 5.2 4.7 3.2 7.7 cobble 7.3 4.2 7.6 3.6 5.1 3.9 7.8 5.6 6.9

¢'*

ESL02015-05 C-27

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C12. Intertidal algae, Sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 1+0.9m (7+3).

+

t, St d.... '

Std, {.

Std.'

+

Std.

Annual Taxon "Mean

+,Dev.

'Mean DeV.:

Mean:

Dev.

+Mean Dev.

'+Mean' Algae Cover non-coralline crust Mastocarpus papillatus Endocladia mur/cata Gelidium coulteri coralline crust Mazzaella affinis Prionitis spp.

Gelidium pus/llum Mazzaella leptorhynchos juv. articulated coralline algae Cladophora spp.

Chondracanthus canaliculatus Ulva spp.

Pterosiphonia dendroidea filamentous red algae complex Invertebrate Counts Chlorostomna funebralis Anthopleura elegantissima Loftia scabra Pa gurus spp.

Lotl/a pelta FissurelIa volcano Lottia limatula Lottia scutum Pachygrapsus crassipes Lottiidae Acanthinuce//a spp.

Ocinebrina spp.

Mopalia spp.

Cyanop/ax spp.

Strongylocentrotus purpuratus Serpulorbis squamigerus Tet rel/ta rubescens Serpulidae Littorina spp.

Grapsidae Nemertea lschnochitonidae Mytilus spp.

Invertebrate Cover Chthamalus fissus Phragmatopoma califomica Spirorbidae 49.7 0.8 4.7 0.7 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 142.0 51.0 44.0 8.6 2.2 1.6 2.0 1.4 0.2 2.2 0.8 0.6 0.4 0.2

<0.1

<0.1 17.0 0.8 8.8 0.7 0.7 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 54.6 49.0 29.2 5.7 2.4 1.8 0.7 1.1 0.4 2.3 0.8 0.5 0.5 0.4

<0.1 58.7 2.7 3.9

<0.1 0.3 0.5 0.2

<0.1 0.1

<0.1

<0.1 77.6 53.0 45.6 3.6 1.0 0.4 0.8 0.4 1.2

<0.1 0.2 0.4 0.4

<0.1

<0.1

<0.1

<0.1 25.4 2.3 8.9

<0.1 0.6 0.9 0.7 0.2 0.3 0.2 65.6 49.1 52.0 3.4 1.7 0.9 0.8 0.9 2.7 0.4 0.9 0.9

<0.1

<0.1

<0.1

<0.1 49.4 19.7 10.8 9.6 4.5 7.9 1.4 1.9

<0.1 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 300.8 211.7 54.0 68.7 70.0 96.5 0.2 0.4 4.6 2.1 1.4 1.9 0.8 1.3 0.6 1.3 1.0 1.0

<0.1

<0.1 0.4 0.9 0.4 0.5 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1 6.0 10.6 0.3 0.9

<0.1

<0.1 60.8 19.1 3.8 3.5 2.0 5.9 1.7 3.0 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 71.6 55.0 45.4 50.5 40.6 18.3 1.2 2.2 1.0 1.0 1.2 1.1 0.2 0.4 0.6 0.9 0.4 0.5

<0.1 0.4 0.9 0.2 0.4

<0.1

<0.1 0.2 0.4 0.2 0.4

<0.1

<0.1 8.6 11.7 0.4 0.9

<0.1

<0.1 54.7 4.5 3.8 0.8 0.3 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 148.0 50.9 50.1 3.4 2.2 1.2 1.0 0.8 0.7 0.6 0.4 0.4 0.2 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 5.8 0.4

<0.1 5.0 7.9 0.5 0.8

<0.1

<0.1 3.5 5.9 0.4 0.9

<0.1

<0.1 (table continued)

'w

  • ESLO201 5-05 C2 C-28

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C12 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC l+0.9m (7+3).

SurVey '

  • 176 177...'

..178 1 9

,Survey Date 12-Feb-14.

.. 13-Jun-14 25-Jul-14 25-Nov-14.....

'Std.

].

Std

.. Std.

S td.

Annual Taxon:

,Mean

0Dev, Mean

'Dev.

,Mean

°Dev.

,Mean Dev;.

.Mean Substrate Cover rock 27.0 15.1 24.7 26.6 20.9 22.8 14.7 13.8 21.8 sand (shell gravel) 5.1 5.2 3.5 3.9 7.3 7.3 6.7 4.4 5.7 cobble 6.4 3.7 4.5 4.4 3.1 2.0 3.3 2.9 4.3 4 'ESLO201 5-05 02 C-29

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C13. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 2+0.3m (8+1).

...Survey 17.171 78.7 S-Survey Date

', 15-Jan-14 14-May-14 10*-Jul-14:

,24-Nov-14 Std.

Std,.

Std.

Std.

Annual TaXon

-Mean 0 ev.*

Mean 0Dev..

Mean 0~ev.

Mean

'Dev.

,. Meani Algae Cover filamentous red algae complex Phyllospadix spp.

non-coralline crust Codium fragile subsp, califomicum coralline crust Gastroclonium subarticulatum Pterosiphonia dendroidea Gelidium coulteri Ulva spp.

Cryptopleura violacea juv. articulated coralline algae Prionitis spp.

Chondracanthus canaliculatus Corallina vancouveriensis Mastocarpus papillatus Sarcodiotheca gaudichaudii Mazzaella affinis Calliarthron/Bossiella s pp.-complex Halymenia/Schizymenia s pp.-complex Smithora naiadum Grateloupia californica Chondracanthus corymbiferus Gelidium pusillum Mazzaella leptorhynchos Farlowia/Pikea spp.-ccmplex Callithanmnion pikeanum Melobesia rnediocris Chlorophyta (filamentous)

Bryopsis spp.

Cladophora spp.

Osmundea spp.

Mastocarpus jardinii Mazzaella ore gona Microcladia coulteri Colpomenia spp.

Invertebrate Counts Tetraclita rubescens Lottia scabra Strongylocentrotus purpuratus Mytilus spp.

Anthopleura elegantissima Fissurella volcano Lottia pelta Paourus s oc.

23.8 18.7 21.0 25.3 29.3 14.1 11.0 14.1 8.5 7.3 3.8 8.2 1.0 1.7 0.6 1.0 0.5 0.9 0.5 0.9 0.2 0.7 0.6 1.2 0.7 0.9 0.8 2.2

<0.1

<0.1

  • <0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 270.6 429.5 61.2 55.9 22.4 36.1 0.8 1.8 17.4 26.8 8.0 5.0 3.4 4.3 7.6 14.8 33.8 27.8 15.6 21.3 8.3 3.2 0.3 1.1 2.4 1.5 1.4 0.9 0.9 0.8 0.7 0.5 0.3 0.3 0.5

<0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1 85.0 54.8 41.2 5.6 6.6 7.4 7.4 22.1 33.6 11.3 24.2 5.0 6.7 0.6 2.5 3.9 2.1 2.1 1.7 1.9 2.4 0.7 1.3 0.9 0.7 1.5

<0.1 0.5

<0.1 0.2 0.2

<0.1

<0.1 153.5

.68.9 56.6 12.5 8.9 5.8 10.1 29.0 31.4 16.7 22.4 6.6 4.7 1.0 3.6 2.5 0.6 0.6 0.8 1.0 0.1 0.6 0.4 0.1 0.4

<0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 163.4 58.2 17.8 44.0 4.4 7.0 2.4 7.0 18.9 38.1 10.6 21.1 5.4 10.0 1.9 6.6 4.9 1.0 2.0 2.0 2.0 0.4 1.2 0.9 0.4 1.3

<0.1 1.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 291.1 94.3 26.2 98.4 7.0 4.6 2.3 5.1 21.0 18.3 23.0 24.6 25.8 19.6 12.8 16.1 11.2 8.7 3.1 5.1 4.0 5.5 1.0 1.1 0.8 1.2 2.8 4.5 1.9 2.8 1.1 1.8 0.7 1.0 0.1 0.4 0.2 0.5 0.4 1.1 0.6 0.9 0.2

.0.7

<0.1

<0.1 0.3 0.6 0.1 0.4 0.1 0.4

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 26.9 25.8 21.8 16.9 8.6 3.7 1.6 1.6 1.6 1.3 1.0 0.9 0.8 0.5 0.4 0.3 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 180.4 55.7 29.2 16.4 10.7 7.9 3.9 3.7 202.6 48.6 35.4 15.0 14.4 9.2 2.4 418.0 78.7 67.3 20.1 27.2 10.7 2.6 (table continued) i ESLO2015-05 C-30

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C13 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 2+0.3m (8+1).

' i" Survey 176,...

177 1...

78 1

79 Sur~vey Date 15-Jan-.14

  • 14-May;14 10-Jul-14 24-Nov-14*

Std. I Std.

.Std. "

... ; Std. -[ Annual Taxon

,.Mean 0 ev...

. Mean 0 ev.

M ean:

eDvI:, Mean 0, ev.

Mean Invertebrate Counts (continued)

Lottia gigantea Serpulidae Lottia scutum Lottia limatula Pachygrapsus crassipes Pollicipes polymenus Epiactis prolifera Chioro stoma brunnea Pugettia spp.

Nuttallina californica Toniicella lineata Ocinebrina spp.

Lottiidae Serpulorbis squamigerus Chioro stoma funebralis Romaleon antennarius Patiria miniata Strongylocentrotus franciscanus Hal/otis spp.

Heptacarpus s pp.

Ischnochitonidae Lacuna spp.

Cyanoplax spp.

Alia spp.

Littorina spp.

Sipuncula Grapsidae Acanthinucella spp.

Acmaea mitra Lottia ochracea Epitonium/Opalia spp.

Doriopsilla albopunctata Pelecypoda boring Amphissa spp.

Aeolidia papillosa Lepidozona spp.

Erato spp.

Betaeus spp.

5.0 1.0 0.4 0.2 0.2 1.6 0.2 0.2

<0.1 0.2

<0.1 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.2 2.2 0.9 0.4 0.4 3.6 0.4 0.4

<0.1 0.4

<0.1 0.4 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 2.8 1.0 1.2 1.4 1.4 0.2 0.4 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 2.7 1.9 0.3 6.3 1.7 2.7 1.9 1.7 0.4 0.9 0.4

<0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 6.9 5.9 1.1 1.4 3.1 1.0 2.2 1.6 3.6 0.2 0.4 1.4 2.6 0.6 0.9 1.2 1.6 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

.<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 5.7 10.0 0.2 0.7 0.6 1.3

<0.1

<0.1 1.4 3.1 1.2 2.7 0.2 0.4 1.6 2.6 0.2 0.4 0.4 0.9 0.4 0.5 0.6 1.3

<0.1

<0.1

<0.1

<0.1 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 2.7 1.1 0.9 0.9 0.8 0.5 0.4 0.4 0.2 0.2 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 6.8 0.6 0.3

<0.1 invertebrate Cover Pista spp.-

Chthamalus fissus Phragmatopoma californica tunicates, compound/social 9.7 14.7 0.1 0.4 0.2 0.7

<0.1

<0.1 8.9 0.1

<0.1

<0.1 13.2 0.4

<0.1 0.2 (table continued) a*-*

ESLO2015-05 C-31

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C13 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 2+0.3m (8+ 1).

Survey 176 177 176 :...

  • 179 Surey ate 15-Jan-14 14-May-14,

10-Jul-14 :.,

24-Nov-14.

Std.

Std.

-Std."

Std.

Annual Taxon "Mean 0' ev'.

Mean' 0ev.

  • Mean 0~ev.

Meain Dev.

Mean Invertebrate Cover (continued)

Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1.

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1I

<0.1

<0.1

<0.1 bryozoa (encrusting)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Dodecaceria fewkesi

<0.1

<0.1

<0.1 Substrate Cover rock 13.7 12.5 6.7 9.6 24.4 14.9 10.9 8.0 13.9 sand (shell gravel) 3.3 5.9 3.7 6.9 4.0 7.1 3.9 6.8 3.7 cobble 2.2 2.5 3.1 2.8 1.8 3.4 2.7 3.4 2.4 I

ESLO2015-05 C3 C-32

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C14. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 2+0.9m (8+3).

survey, 176 177 178 179 Survey Date 1

l5-;Jan-14 14-May-14 10-Jul-4..

10-Oct-14' Std...

=

Std.*v, Std.,**4 Std.

Annual,*

Taxon

. Mean>..

Dev.

Mean 0...

ev.

M~ean....

0ev.

Mean Dev.

Mean Algae Cover

  • non-coralline crust U/va spp.

Endocladia muricata Gelidiurn coulteri Mastocarpus papillatus filamentous red algae complex coralline crust Chrysophyta Mazzae/la aff/nis Ge/id/urn pusillurn Porphiyra spp.

Cora/llina vancouveriensis juv. articulated coralline algae Pr/on/i/is spp.

Cod/urn fragile subsp. californicurn Ohondracanthius coyrnmb/ferus C/adophora spp.

Chiondracanthus cana/iculatus Chiorophyta (filamentous)

Colpornenia spp.

Mazzaella leptorhynchos Pterosip/honia dendro/dea Sarcod/othieca gaudichaud/i Cryptopleura vio/acea Macrocystis pyrifera Invertebrate Counts Loft/ia scabjra Chlorostorna funebra/is Anthop/eura elegantissirna Mytilus spp.

Siron gy/ocentrotus purpuratus Pa gurus spp.

Loll/a lirnatula Loll/a pelta Loll/a gigantea Loll/a scuturn Pachygrapsus crass/pes Acanthinuce/la spp.

Fissurel/a volcano Cyanop/ax spp.

Tetraclita rubescens Lottiidae Ba/anus spp.

-Oc/ne/br/na spp.

7.2 8.9

<0.1

<0.1 3.1 4.6

<0.1

<0.1

<0.1

<0.1 0.8 2.6 1.7 1.5

<0.1

<0.1 0.4 1.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 16.0 20.2 3.3 6.0 5.4 8.6 0.8 1.9 0.8 1.1 0.4 0.9 1.0 1.1

<0.1

<0.1

<0.1 1.5 2.8 0.7 1.2 0.3 0.6 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 133.0 61.1 43.8 75.9 32.0 33.5 19.6 30.7 10.2 14.4 5.0 7.1 2.6 2.1 4.8 6.1 3.4 5.0 3.0 3.0 0.8 0.4 1.8 2.2 1.4 2.2 0.2 0.4 1.4 2.6

<0.1 1.0 0.7 9.6 16.1 6.0 2.1 3.0 0.8 1.7 3.8 0.8 0.9

<0.1

<0.1 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 78.6 100.6 21.6 14.8 8.0 3.8 5.4 2.2 2.4 2.0 3.8 0.6 1.8 2.6 2.4 0.6 3.2 0.8 12.6 10.3 8.7 2.1 2.8 2.0 2.2 7.9 1.0 1.4

<0.1

<0.1 1.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 32.0 216.0 20.6 22.0 13.1 5.2 1.7 1.6 3.4 2.5 2.6 0.9 2.0 2.2 2.3 1.3 4.6 0.8 9.3 5.6 7.5 12.5 3.1 4.7 1.4 1.6 0.8

<0.1 0.1 0.4 0.1

<0.1

<0.1

<0.1 91.8 0.4 34.4 39.2 0.6 0.4 1.6 3.6 2.8 2.4 0.2 1.0 0.4 0.6 1.0 1.0 9.2 5.5 11.9 9.8 3.5 5.7 2.0 1.1 0.7

<0.1 0.3 1.1 0.3 0.2

<0.1

<0.1 26.0 0.9 64.3 74.0 1.3 0.9 1.7 6.5 3.8 3.4 0.4 1.7 0.5 0.9 2.2 1.2 10.5 6.2 5.5 3.8 1.7 1.7 1.5 0.9 0.6 0.4 0.4 0.3 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 115.1 56.7 34.0 23.7 5.4 5.4 4.2 3.5 3.1 2.7 1.5 1.1 1.1 1.1 1.1 1.0 0.8 0.8 157.0 81.8 48.0 21.2 2.8 12.4 7.0 3.4 3.6 3.4 1.2 1.0 0.8 0.8 0.4 2.2 0.4 64.7 64.1 64.0 36.4 3.3 9.6 3.5 4.9 5.4 2.5 1.3 1.4 1.1 0.8 0.5 2.2 0.9 (table continued) aW-

'ESLO2015-05 C-33

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C14 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 2+0.9m (8+3).

Survey 176 177 178 179 Survey Date 15-Jan-14 14-May-14 10-Jul-4 10-Oct-14 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev.

Mean.

Dev.

Mean Dev.

Mean Dev.

Mean Invertebrate Counts (continued)

Mopalia spp.

0.4 0.5 0.4 0.5 0.2 Nuttallina califomnica 0.6 0.5 0.2 0.4 0.2 Pollicipes polymerus

<0.1

<0.1

<0.1

<0.1 0.4 0.9 0.1 Nemertea 0.2 0.4

<0.1 Littorinaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Sipuncula

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1 Crepidula spp.

<0.1

<0.1

<0.1 Epitoniurn/Opaliaspp.

<0.1

<0.1

<0.1 Lirobittium spp.

<0.1

<0.1

<0.1 Pugettiaspp.

<0.1

<0.1

<0.1 Heptacarpus spp.

<0.1

<0.1

<0.1 Invertebrate Cover Chthamalusfissus 14.6 7.8 9.7 7.1 9.5 6.8 10.3 6.8 11.0 Phragmatopoma califomica 1.9 2.0 1.2 1.5 0.6 1.2

<0.1

<0.1 0.9 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Substrate Cover rock 68.6 10.1 57.9 23.7 51.6 19.7 46.1 15.2 56.1 cobble 1.8 3.0 0.1 0.4 0.8 2.2 1.7 5.0 1.1 sand (shell gravel)

<0.1

<0.1 0.6 2.0

<0.1

<0.1

<0.1

<0.1 0.2 I

ESLO2015-05 03 C-34

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C15. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 mn

2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 3+0.3m (9+1).

Survey 176 177 178 179 Suvetdt.3-n1 StdAr-1 27-Jn-1 Std.oAnnua Suvetatd3-an 30-Ar-1 2-Jn-1 7-Nov-14u Taxon Mean 0ev.

Mean Dev.

Mean 0ev.

Mean Dev.

Mean Algae Cover non-coralline crust Cod/urn fragile subsp. californicurm coralline crust Ge/idiurn coulteri filamentous red algae compiex Ulva spp.

Pterosiphonia dendroidea Crypto pleura violacea Chrysophyta Coral/ina vancouver/ens/s juv. articulated coralline algae Call/art hron/Bossiella spp.-complex Acrosor/urn c/lie/aturn Chiorophyta (filamenteus)

Macrocystis pyrifera Endarachne/Petalonia-complex Mazzaella affinis Ge/id/urn pus/i/lurn Mastccarpus pap/i/at us Chondracanthus canaliculatus Prionitis spp.

Far/owia/Pikea spp.-ccmplex Co/pornenia spp.

Cladophora spp.

Grateloupia ca/ifernica Halyrnenia!Schizymenia spp.-complex Laminariales Callophyllis spp.

Halosaccion americanurn Chendracanthus corymbiferus Bryopsis spp.

Mazzaella flaccida Invertebrate Counts Tetraclita rwbescens Mytilus spp.

Loll/a scabra F/ssurella volcano Strongylccentrotus purpuratus Anthopleura elegantissirna Lottia pelta

.Loll/a gigantea Epiactis prol/fera Fachygrapsus crass/pes 31.

23.

9.

1.

2.

1.

0.

0.

2.

1.

3.

2.

0.

2 23.0 4

13.0 9

8.6 7

2.5 8

4.2 9

2.2 1

0.3 5

1.1

7.

4.9 3

2.2 8

4.6 2

3.1 9

1.4 1

0.4 1

<0.1 1

<0.1 1

<0.1 1

<0.1 1

<0.1 0.

<0.

<0.

<0.

<0.

<0.

611.*

12.

53.z 35.z 25.,

3.(

5.;

7.;

5.

1.;

34.9 21.4 28.3 18.8 7.2 3.9 4.5 6.6 4.4 5.2 7.0 4.8 3.8 2.1 2.0 3.5 4.6 6.3 4.2 7.2 2.3 2.2

<0.1

<0.1 0.6 1.1 0.5 1.1

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 492.4 325.7 190.6 426.2 29.6 22.1 10.2 4.0 20.0 22.3 0.6 0.5 2.8 4.2 3.4 3.6 0.2 0.4 1.0 1.4 28.1 15.2 37.7 24.6 11.5 5.8 9.7 10.0 3.3 2.0 4.1 2.3 6.5 6.0 4.1 5.3 4.0 8.3 0.8 1.1 2.3 1.9 1.2 1.9 0.3 0.9 0.3 0.9 0.3 0.9

<0.1

<0.1

<0.1 0.2 0.1 0.4 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 675.8 408.4 206.4 443.2 32.4 17.5 16.8 6.8 21.0 25.3 16.0 31.4 7.0 5.8 1.2 1.6 4.6 10.3 2.4 1.3 26.7 16.6 23.7 15.7 8.5 3.1 6.5 10.4 6.9 5.5 0.6 1.1 2.2 4.1 3.7 6.1 0.3 0.7 1.9 1.8 1.7 1.8

<0.1

<0.1 0.3 0.9

<0.1 0.2

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 392.0 246.3 70.2 148.1 28.6 28.1 17.2 11.0 6.2 4.4 33.6 73.5 5.8 5.8 2.0 2.3 2.0 2.9 1.2 1.3 30.2 28.3 9.3 5.6 4.4 3.4 3.2 2.6 2.1 2.0 1.9 1.7 0.5 0.4 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 543.0 120.0 36.0 19.9 18.1 13.3 5.2 3.5 3.1 1.5 6

6 4

4 2

0 2

2 4

2 221.4 24.4 20.1 16.5 14.3 2.0 3.0 9.0 9.4 1.8 (table continued)

'W ESLO2015-05 C-35

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C15 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 3+0.3m (9+1).

.'Survey 176 T..

177...

.178" 179 Survey Date :

31-Jan-14.

30-Apr-14 "27-Jun-14 7-Nov-14 S....

Std. j Std.

Std.

Std.

'Annual TxnOean De. jMean

Dev*.
  • Mean i iDev. -Mean:

Dev.

Mean Invertebrate Counts (continued)

Serpulidae Lottia scutum Lottia limatula Nuttallina californica Balanus spp.

Nemertea Anthopleura artemisia Serpulorbjis squamigerus Pugettia spp.

Ant hopleura xanthogrammica Cyanoplax spp.

Diodora spp.

Pisaster ochraceus Fissurellidea bimaculata Ocinebrina spp.

Haliotis spp.

Lottiidae H-eptacarpus spp.

Ischnochitonidae Pollicipes polymerus Grapsidae Urticina spp.

Corynactis califomica Epitonium/Opalia spp.

Ophiuroidea Majidae Septifer bifurcatus L ysmnata califomnica Invertebrate Cover Phragmatopoma califomica Chthamalus fissus Haliclona spp.

Spirorbidae Porifera (encrusting) bryozoa (encrusting) tunicates, compound/social Pista spp.

Substrate Cover rock cobble sand (shell gravel) 1.6 1.7 0.8 1.8 0.8 0.8 0.4 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.8 0.8 0.2 0.4 1.0 1.7 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1 1.7 2.6 1.8 3.1

<0.1 0.2 16.9 18.5 6.0 8.0

<0.1

<0.1 1.2 2.7 2.8 3.6 0.4 0.5 0.4 0.9 0.4 0.5 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.8 1.3 0.2 0.4 1.0 2.2 0.4 0.9 1.0 2.2 0.4 0.5 0.2 0.4 0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.5 2.5 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 29.7 19.3 3.7 4.0

<0.1

<0.1 1.1 1.0 0.6 0.3 0.3 0.2 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.0 0.7

<0.1

,<0.1

<0.1

<0.1

<0.1 24.4 24.4

<0.1 0.4 0.7

<*0.1

<0.1

<0.1

<0.1

<0.1 31.7 4.4 0.2 0.9 1.0

<0.1

<0.1

<0.1

<0.1 24.8 6.5 0.7 0.5

<0.1

<0.1

<0.1

<0.1 0.8

<0.1

<0.1

<0.1 19.4 17.0 3.5 5.1

<0.1

<0.1

  • -/ES L020 15-05 03 C-36

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C16. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 3+0.9m (9+3).

Survey 16 7177 178

'179 survey Date 31-Jan-14

.. 30-Apr-14 27-Jun-14 7-Nov-14

(....

Std I

Std.

- Std.

Std.

Annual

Taxon
Mean, 0ev.ev, Mean...,Dev.,

Mean.

.0ev.

Mean.

Dev...

Mean Algae Cover non-coralline crust Codium fragile subsp. californicum Ulva spp.

Chrysophyta filamentous red algae complex coralline crust Gelidium coulteri Pterosiphonia dendroidea Mastocarpus papillatus Calliarthron/Bossiella spp.-complex Crypto pleura violacea juv. articulated coralline algae Chlorophyta (filamentous)

Mazzaella affinis Porphyra spp.

Prionitis spp.

Gelidium pusillum Laminariales Macrocystis pyrifera Endarachne/Petalonia-complex

,Cladophora spp.

Corallina vancouveriensis Colpomenia spp.

Endocladia muricata Mastocarpus jard~iri Chondracanthus canaliculatus Mazzaella leptorhynchos Mazzaella ore gona Microcladia coulteri Acrosorium ciliolatum Invertebrate Counts Tetraclita rubescens Mytilus spp.

  • Lottia scabra Lottia gigantea Strongylocentrotus purpuratus Fissurella volcano Anthopleura elegantissima Lottia pelta Chioro stoma funebralis Pachygrapsus crassipes Lottiidae Lottia limatula 27.1 5.5 0.3 1.9 2.4 0.5

<0.1

<0.1

<0.1

<0.1 0.2 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 198.2 81.4 99.6 21.2 19.4 11.6 0.8 4.4 4.2 3.6 2.6 20.7 7.8 0.9 5.2 2.1 0.8

<0.1

<0.1

<0.1

<0.1 0.7 1.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 202.6 104.1 61.8 22.9 25.4 14.6 1.3 5.0 7.2 4.8 5.3 26.0 22.9 5.7 8.9 5.8 8.0 5.9 11.2 2.9 7.0 3.1 2.4 1.5 1.4 0.8 1.2 0.2 0.5

<0.1 0.2

<0.1 0.2

<0.1

<0.1 0.6 2.0

<0.1

<0.1 0.2 0.7 0.1 0.4

<0.1 0.2

<0.1I

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 88.6 99.1 73.2 95.1 60.0 44.9 13.0 13.8 19.2 25.3 3.4 2.9 0.6 0.9 2.8 5.2 5.0 10.6 4.6 3.6 3.2 6.1 2.6 3.6 28.8 15.8 9.1 11.9 13.2 11.2 13.8 17.5 1.2 2.4 2.2 3.4 5.1 4.4 1.7 3.2 0.6 0.9

<0.1 0.2

<0.1

<0.1 0.1 0.4 0.5 0.9

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 29.1 6.5 2.6 9.3 3.7 3.7 0.3 0.2 0.8 0.7 0.3 0.2 0.1 0.4 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 42.4 67.2 36.0 13.0 7.2 8.2 18.0 8.2 0.6 0.4 1.6 19.7 10.1 4.1 17.0 5.6 2.8 1.1 0.7 1.9 2.0 0.5 0.7 0.4 1.3 0.6

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 79.9 88.0 27.9 16.5 6.3 9.1 35.9' 9.3 0.5 0.9 2.6 27.7 6.7 5.5 4.9 3.8 2.8 2.7 0.7 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 104.5 66.2 56.5 16.2 16.0 7.9 5.2 4.4 2.3 2.3 2.1 2.1 88.8 42.8 30.4 17.4 18.2 8.2 1.2 2.2 3.8 1.2 1.6 96.4 56.5 7.1 20.5 17.7 7.8 2.2 1.3 2.3 2.7 2.1 (table continued) a'*ESLO2015-05 C-37

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C16 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for North Diablo Cove Station NDC 3+0.9m (9+3).

Survey 176 177

,178 179 Survey Date 31-Jan-14 30-Apr-14 27-Jun-14 7-Nov-14 Std.

Std.

Std.

Std.

Annual Taxon Mean 0ev.

Mean Dev.

Mean 0ev.

Mean Dev.

Mean Invertebrate Counts (continued)

Lottia scutumn Epiactis prolifera Pa gurus spp.

Serpulidae Natantia Pollicipes polymerus Acanthinucella spp.

Nuttallina califomnica Pelecypoda boring Cyanoplax spp.

Nucella spp.

Ophioplocus esmarki Pugettia spp.

Lepidozona spp.

Littorina spp.

Grapsidae Sipuncula Ischnochitonidae Heptacarpus spp.

Diodora spp.

Patiria miniata Ophiuroidea Cucumaria spp.

Invertebrate Cover Chthamalus fissus Phragmatopoma califomica Pista spp.

bryozoa (encrusting)

Spirorbidae tunicates, compound/social Porifera (encrusting)

Substrate Cover rock cobble sand (shell gravel) 0.4 0.5 0.4 0.9

<0.1

<0.1 0.4 0.9

<0.1

<0.1

<0.1

<0.1 7.6 6.0 0.5 1.1 0.1 0.4

<0.1

<0.1 49.7 17.9 2.5 6.0 3.2 7.2 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 5.9 7.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 45.1 26.4 3.5 5.4 1.2 2.0 1.2 1.0 1.2 0.6 0.8 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 6.7

<0.1 0.1

<0.1

<0.1

<0.1 1.8 2.3 2.7 0.7 1.8 1.3 1.8 0.4 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.7

<0.1 0.4

<0.1

<0.1

<0.1 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1 6.5 8.2 0.4 0.9

<0.1

<0.1

<0.1

<0.1 41.7 20.3 1.9 3.0 1.3 0.6 0.4 0.4 0.3 0.3 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 6.6 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 42.8 2.4

<0.1 34.7 21.2 1.8 2.6

<0.1

<0.1 C*' ESLO2015-05 C-38

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C17. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC l+0.3mn (10+1).

Survey 176 177 178 179 Survey Date 2-Jan-14 15-May-14 14-Jul-4 5-Dec-14 Std.

Std.

Std.

Std.

Annual Taxon *Mean Dev.

Mean Dev.

Mean 0ev.

Mean Dev.

Mean Algae Cover filamentous red algae complex 23.1 11.9 24.2 9.6 16.0 7.3 27.6 10.2 22.7 coralline crust 18.1 12.8 16.1 11.3 22.8 16.9 31.0 22.3 22.5 non-coralline crust 15.6 10.4 18.6 11.0 17.9 15.3 11.7 12.6 16.0 Prionitis spp.

<0.1 0.2 0.7 0.8 4.4 4.7 5.2 5.0 2.6 Gastroclonium subarticulatum 1.4 2.6 2.6 4.6 2.4 4.0 3.7 4.8 2.5 Gelid/urn coulteri 3.1 6.8 0.7 1.1 4.5 7.4 0.2 0.7 2.1 Cryptopleura violacea 0.3 1.1 0.3 0.9 4.7 4.5 1.7 2.8 1.8 juv. articulated coralline algae

<0.1

<0.1 5.1 6.1

<0.1

<0.1 1.7 1.8 1.7 Ulva spp.

<0.1

<0.1 3.9 2.2 2.4 2.8

<0.1

<0.1 1.6 Chrysophyta 4.1 3.0 1.0 Gelidiurn pusillurn 0.1 0.4 1.3 3.0 2.1 4.8 0.9 Chondracanthus canaliculatus 0.8 2.2 0.5 1.0 0.5 1.1 0.6 1.0 0.6 Sargassum muticum 0.3 0.7 0.6 1.3

-0.2 Mazzae//a affinis

<0.1

<0.1 0.2 0.5 0.3 0.8 0.1 Pterosiphonia dendroidea 0.3 1.1

<0.1 0.2

<0.1 0.2

<0.1

<0.1 0.1 Core/line vancouveriensis 0.2 0.3

<0.1

<0.1

<0.1 0.2

<0.1 Calliart hron/Boss/ella spp.-complex 0.1 0.4

<0.1

<0.1 0.1 0.3

<0.1 Colpomenia spp, 0.3 0.5

<0.1

/-alyrmenia/Schizymenia spp.-complex

<0.1 0.2

<0.1 0.2

<0.1 Mastocarpus papi/latus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Cladophora spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Grate/oupia ca//forn/ca

<0.1

<0.1

<0.1 Mazzeella leptorhynchos

<0.1

<0.1

<0.1 Mazzae/la ore gona

<0.1

<0.1

<0.1 Chlcrophyta (filamentous)

<0.1

<0.1

<0.1 Invertebrate Counts Strongylocentrotus purpuratus 33.0 44.4 39.2 42.0 24.2 24.0 24.1 Anthop/eura elegantissirna 26.8 12.4 18.6 8.8 22.4 16.0 27.4 16.9 23.8 Fissure//a vo/cano 15.0 9.2 7.6 5.3 5.8 5.8 17.0 18.1 11.4 Tetrac/ita rubescens 17.6 21.4 2.4 3.3 7.0 11.7 7.6 13.2 8.7 Pagurus spp..

5.4 4.8 0.8 1.3 6.6 8.4 3.2 Lollia pelta 2.0 1.2 1.4 2.1 0.6 1.3 1.6 1.5 1.4 Loll/a /irnatu/a 0.4 0.5 1.4 1.7 1.8 3.0 1.6 1.8 1.3 Epiactis pro/ifera 0.4 0.9 0.4 0.9 0.2 0.4 1.4 1.5 0.6 Loll/a scabra 0.2 0.4 1.8 3.5 0.5 Loll/a scuturn 0.2 0.4 1.4 2.6 0.4 0.9

-0.5 Cirratu[idae/Terebellidae 0.6 0.9 1.4 2.2 0.5 Nemertea 0.8 1.8 0.4 0.9 0.3 Ophiiothrix spicu/ata 1.0 1.7 0.2 0.4 0.3 Ch/orostorna brunnea 0.8 1.3 0.2 Pugettia spp.

0.2 0.4 0.2 0.4 0.2 0.4 0.2 Serp u/orb/s squarnigerus 0.4 0.9 0.2 0.4 0.2 Pachygrapsus crass/pes 0.4 0.9 0.2 0.4 0.2 (tab/e continued)

I/*

ELO205-05C-39

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C17 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC l+0.3m (10+1).

Survey

176 177 178 '...

179

", Survey Date 2-Jan-14, 15Ma-1 14Jl-4 5-Dec-14...

Std; S tdi.

Std. '

.... Std.

'Annual Taxon...

Mean *"Dev.:

Mean

  • Dev.

Mean Dev.

Mean' Dev.

Mean Invertebrate Counts (continued)

Chaetopteridae 0.6 1.3 0.2 Anthopleura artemisia

<0.1

<0.1 0.4 0.5 0.1 Cyanoplax spp.

0.2 0.4

<0.1

<0.1 0.2 0.4 0.1 Aeo/idia papil/osa 0.4 0.9 0.1 Sipuncula 0.2 0.4

<0.1

<0.1

<0.1 Ophiactis simp/ex 0.2 0.4

<0.1

<0.1

<0.1 Chloro stoma funebra/is 0.2 0.4

<0.1 Pelecypoda boring 0.2 0.4

<0.1 Lottiidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Bar/eeiaspp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Alia spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Epitonium/Opalia spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Ischnochitonidae

<0.1

<0.1

<0.1

<0.1

<0.1 Heptacarpusspp.

<0.1

<0.1

<0.1

<0.1

<0.1 Amphipholis squamata

<0.1

<0.1

<0.1 Mopaliaspp.

<0.1

<0.1

<0.1 Loftia ochracea

<0.1.

<0.1

<0.1 Lacuna spp.

0.1

<0.1

<0.1 Cancridae

<0.1

<0.1

<0.1 Amphissaspp.

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1 Ap/ysia spp.

<0.1

<0.1

<0.1 Invertebrate Cover Pista spp.

0.3 0.6

<0.1

<0.1 0.1 0.4

<0.1

<0.1 0.1 Chthamna/us fissus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1,

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Phragmnatopoma ca//tom/ca

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Dodecaceria fewkesi

<0.1

<0.1

<0.1 tunicates, compound/social

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 Substrate Cover rock 21.7 12.2 14.7 7.2 14.1 9.8 11.0 6.8 15.4 cobble 4.7 5.9 5.4 6.4 1.8 2.3 4.2 6.7 4.0 sand (shell gravel) 2.3 4.1 2.4 3.2 3.7 5.9 4.2 6.3 3.2 ESLO2015-05 C-40

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C18. Intertidal.algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 1+0.6m (10+2).

Survey -

176...

,: I 177 1":

78 1....'

79 S..

urvey Date

" 2-Jan-14 is-May-14 14-Jul-14 5-Dec-14 I

t.~..:

td Sd Std.

Annual

Taxon, Mean,;De.,,
  • Mean.

0ev.,

Mean

,Dev.

Mean 0 ev.

Mean Algae Cover nlon-coralline crust filamentous red algae complex coralline crust Gastroclonium subarticulatum Gelidium coulteri Prionitis spp.

Chondracanthus canaliculatus Crypto pleura violacea Ulva spp.

Gelidium pusillumn Mazzaella affinis juv. articulated coralline algae Chrysophyta Mastocarpus papillatus Crypto pleura ruprechtiana Fucus gardneri Corallirna vancouveriensis Calliarthron/Bossiella s pp.-complex Mastocarpus jardinfi Cladophora spp.

Plerosiphonia dendroidea Colpornenia spp.

l-alymenia/Schizymenia spp.-complex Halosaccion americanum Grateloupia califomica Chiorophyta (filamentous),

Invertebrate Counts Anthopleura elegantissima Tetraclita rubescens Fissurella volcano Strongylocentrotus purpuratus Lottia pelta Pa gurus spp.

Lottia limatula Lottia scabra Pachygrapsus crassipes Chioro stoma funebralis Epiactis prolifera Lottia scutum Pugettia spp.

Cyanoplax spp.

Ant hopleura artemisia Nemertea 33.6 17.0 10.1 5.9 7.8 0.6 1.3 0.3

<0.1 0.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 40.0 38.8 15.2 13.6 3.4 4.0 1.8 0.4 2.2 0.4

<0.1

<0.1

<0.1 7.8 9.9 5.1 6.1 3.8 1.3 1.7 0.9

<0.1 0.6 0.2

<0.1

.0.2

<0.1

<0.1

<0.1 23.3 44.3 7.4 13.8 1.7 3.4 1.3 0.5 4.9 0.9

<0.1

<0.1

<0.1 23.8 11.3 18.9 11.6 12.4 10.2 10.7 9.3 6.2 6.3 1.9 2.5 1.7 3.1 0.8 1.3 3.4 2.8 2.4 3.5 0.3 0.6 1.6 3.1 2.2 1.7 0.6 1.8

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 23.7 10.6 12.2 7.6 8.3 5.1 11.8 10.5 18.3 5.2 4.9 4.2 0.6 1.0 1.4 2.1 2.4 1.5 0.7 1.0 2.2 2.7

<0.1 0.2

<0.1

<0.1 0.4 1.3 0.3 0.9

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 35.8 11.5 6.8 5.9 3.6 2.5 17.4 18.9 6.6 5.5 5.6 3.9 2.0 1.4 1.0 0.7 2.6 1.8 0.2 0.4 0.2 0.4

<0.1

<0.1 0.2 0.4 0.4 0.5 23.7 8.8 18.3 6.7 16.0 17.0 12.4 9.4 3.5 2.3 5.2 3.7 3.3 4.0 4.0 3.6

<0.1

<0.1

<0.1

<0.1 0.3 0.9 1.1 2.1

<0.1

<0.1

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 48.2 24.8 21.4 30.5 23.4 15.4 7.2 4.9 3.8 3.7 3.2 5.0 0.4 0.9 1.6 2.1 1.2 1.8 0.2 0.4 26.2 16.6 11.7 10.2 9.0 3.2 1.7 1.6 1.4 0.8 0.7 0.7 0.6 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 38.0 16.8 11.8 11.2 5.4 3.2 2.3 1.3 1.1 0.6 0.4 0.4 0.2 0.1 0.1 0.1 28.0 5.0 13.8 4.4 3.0 1.6 1.0 1.0 0.4 0.2 0.2 21.4 2.5 12.0 3.0 5.1 1.9 1.7 1.4 0.5 0.4 0.4 (table continued) a#'wESLO2015-05 C-41

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C18 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 1+0.6m (10+2).

Survey 176 177 T

178 T

179 Survey Date 2-Jan-14 15-May-14

.14-Jul-4 5-Dec-14 Std.

Std. IStd.

I Std.

Annual Taxon Mean Dev.

Mean Dev. jMean Dev.

Mean Dev."

Mean invertebrate Counts (continued)

Chlorostoma hrunnea Pisaster ochraceus Fissurellidea lbimaculata Cirratulidae/Terebellidae Barleeia spp.

Pelecypoda boring Acanthinucella spp.

Diodora spp.

Mopalia spp.

Serpulorbis squamnigerus Octopus spp.

Nuttallina californica Ocinebjrina spp.

Ophiothrix spiculata Serpulidae Lottiidae lschnochitonidae Heptacarpus spp.

Alia spp.

Sipuncula Epitonium/Opalia spp.

Chaetopteridae Mytilus spp.

Lottia ochracea Grapsidae 0.4 0.5 0.2 0.4

<0.1

<0.1

<0.1 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.4 1.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.8 6.1 5.3 6.3 1.3 1.2 0.2 0.4 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.4 0.9 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.4 0.4 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 11.3 4.1 3.7 Invertebrate Cover Pista spp.

Chthamalus fissus Spirorbidae Phragmatopoma califomica Dodecaceria fewkesi tunicates, compound/social Porifera (encrusting) bryozoa (encrusting)

Substrate Cover rock cobble sand (shell gravel)

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 9.8 4.5 3.7 9.4 3.6 5.1 11.7 8.2 3.2 4.3 5.6 6.4 14.8 10.6 3.6 5.0 4.2 5.4

"*W PESLO201 5-05 C-42

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C19. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 2+0.3m (11+1).

Survey 176 177 T

178 179 Survey Date 3-Jan-14 29-Apr-14 24-Jun-14 5-Nov-14

.Std.

Std.

Std.

,,Std.

Annual Taxon Mean Dev.

Mean 0 ev.

Mean 0ev.

Mean Dev.

Mean Algae Cover non-coralline crust filamentous red algae complex coralline crust Prionifis spp.

Ulva spp.

Crypto pleura violacea Corallina vancouveriensis Gastroclonium subarticulatum Chiondracanthus canaliculatus Gelidium pusillum Gelidium coulteri Plerosiphonia dendroidea Chrysophyta Sargassum muticum Mastocarpus papillatus juv. articulated coralline algae Mazzaella affinis Halymenia/Schizymenia spp.-complex Grateloupia californica Macrocystis pyrifera Chondria decipiens Cladophora spp.

Mazzaella leptorhynchos Colpomenia spp.

Calliarthron/Bossiella spp.-complex Chlcrophyta (filamentous)

Mastocarpus jardinll Invertebrate Counts Anthopleura elegantissima Chlorostorna funebralis Tetraclita rubescens Lottia limatula Fissurella volcano Lottia pelta Pa gurus spp.

Lottia scabra Pachygrapsus crassipes Strongylocentrotus purpuratus Lottia scutum Serpulorbis squamigerus Mopalia spp.

Cyanoplax spp.

Pisaster ochraceus 48.8 17.2 14.0 19.8 10.6 5.5 3.8 5.8

<0.1

<0.1 0.3 1.1

  • 2.6 5.1 1.1 2.1 0.9 1.9 1.3 2.3 S0.3 0.5

<0.1

<0.1 0.3 1.1 0.5 1.1

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1 42.2 8.2 139.6 157.8 37.8 35.0 2.6 4.2 3.8 3.3 0.8 0.4 1.6 2.6 0.6 0.9 0.4 0.5 0.6 0.9 0.4

.0.9 0.2 0.4

<0.1

<0.1 34.7 20.6 14.2 20.3 12.9 13.7 5.9 4.0 2.1 1.5 6.5 6.7 2.4 4.1 1.9 3.0 1.1 2.1 0.6 0.9 0.8 1.3 1.9 5.9

<0.1

<0.1 1.0 1.3

<0.1

<0.1

<0.1 0.2 0.2 0.5 0.2 0.7

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 53.4 25.3 0.2 0.4 8.8 10.4 3.2 3.6 0.4 0.5 3.0 2.1 0.2 0.4 1.2 1.8 1.0 2.2 0.4 0.5 0.2 0.4 0.2 0.4 0.4 0.5 0.4 0.9 32.7 14.2 10.8 9.2 19.7 8.5 1.0 1.2 1.7

<0.1 4.3 2.2

<0.1 2.5 0.6 1.2 0.8

<0.1

<0.1

<0.1

<0.1 26.2 0.4 7.0 2.6 1.2 1.6 6.2 5.2 3.0 1.2 0.8 0.6 0.4 0.4 12.7 20.5 12.1 5.8 12.1 7.1 1.6 2.5 2.1

<0.1 4.4 6.8

<0.1 4.1 1.2 1.2 2.0

<0.1

<0.1

<0.1

<0.1 15.5 0.9 5.8 2.3 1.8 1.5 3.1 7.9 0.7 1.8 1.3 1.3 0.5 0.5 50.1 18.8 13.7 16.3 6.8 8.0 15.0 14.1

<0.1 0.2 2.4 2.7 1.8 2.1 3.4 3.5 3.5 3.8 5.0 6.3 1.5 2.0 5.2 6.0 3.5 5.2 0.6 1.3 0.4 0.9 0.3 0.6

<0.1 0.2

<0.1

<0.1 27.8 8.3 9.4 10.8 21.4 18.8 6.8 5.0 5.6 2.1 5.0 4.9 2.4 3.3 1.6 2.5 1.6 2.1 0.8 1.1 0.6 0.9 0.8 1.3 0.6 1.3

<0.1

<0.1 41.6 14.1 10.3 8.5 5.5 4.4 2.0 1.9 1.8 1.7 1.7 1.3 1.0 0.9 0.9 0.6 0.4 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 37.4 37.4 18.8 3.8 2.8 2.6 2.6 1.7 1.6 0.9 0.6 0.5 0.3 0.2 0.2 T

(table continued) 0-ESLO2015-05 C-43

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C19 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 2+0.3m (11+1).

Survey 176..

17

{

17 8

{'

179

°SureyeYDate 3-Jan-14

29-Apr-14...

24-Jun6-14..

.5-Nov-14'*

.Std,.

  • Std.

,Std.

Std.

Annual, Taxon iMean Dev.

"Mean 0ev. j Mlean,

0 ev.

Mean 0 ev.

Mean Invertebrate Counts (continued)

Leptasterias spp.

Anthopleura artemisia Epiactis prolifera Diopatra omata Nemertea Ophiothrix spiculata Septifer bifurcatus Cirratulidae/Terebeflidae Lottiidae Barleeia spp.

Epitoniurn/Opalia spp.

Serpulidae Heptacarpus spp.

Alia spp.

Hermissenda crassicornis Ischnochitonidae Sipuncula Grapsidae Acmaea mitre Pycnogonida Idotea spp.

Pelecypoda boring Pugettia spp.

Aeolidia papillosa Chaetopteridae Haminoea spp.

Mytilus spp.

Invertebrate Cover Phragrnatopoma californica Chthamalus fissus Spirorbidae Porifera (encrusting)

Dodecaceria fewkesi Pista spp.

tunicates, compound/social bryozoa (encrusting)

Substrate Cover rock sand (shell gravel) cobble 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.4 0.4 '

0.5 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 4.8 4.1 0.4 0.9

<0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 4.4 2.5 0.8

<0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.9 4.1 1.4 0.2 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.8 2.4 0.6 0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.7 2.2 0.8 0.4

<0.1

<0.1

<0.1 8.2 2.4 2.0

<0.1

<0.1

<0.1

<0.1 17.4 20.3 4.7 6.8 0.8 1.3 a(WESLO2015-05 C-44

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C20. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 2+0.9m (11+3).

.Survey 17

.,177...

  • ...178.

T79 i=...*

.... Survey Date 3...

Jan-1*4,

29-Apr-14

',24-Jun,14 5-Nov-14 Std.

Std.

Std.

Std.

  • Annual STaXon,.

Mean,

Dev.

Mean gev.

-Mean '

Dev.. j Mean',

Dev.

Mean Algae Cover non-coralline crust 28.6 21.8 25.5 26.0 27.2 24.3 33.1 28.2 28.6 Prionitis spp.

1.2 1.4 1.2 1.4 3.5 3.9 3.7 2.5 2.4 Mastocarpus papillatus 1.0 1.9 1.2 2.5 6.2 6.5 1.1 1.1 2.4 Endocladiarnuricata 2.6 7.2 1.7 4.2 0.4 1.3 0.3 1.1 1.3 coralline crust 0.3' 0.7 1.3 2.0 1.0 1.2 0.4 0.7 0.7 Ge/idiurn pusillurn 0.6 2.0

<0.1

<0.1I 0.3 0.9 0.9 1.8 0.5 Ge/idiurn coulteri

<0.1

<0.1 0.5 0.9 1.4 1.6

<0.1

<0.1 0.5 Corallina vancouver/ens/s 0.7 1.2 0.3 0.5 0.3 0.9 0.4 0.7 0.4 Grate/oupia californica 1.0 2.3 0.3 juv. articulated coralline algae

<0.1

<0.1 0.3 0.5 0.2 0.5

<0.1

<0.1 0.1 Mazzael/a /eplorhynchos

<0.1

<0.1

<0.1

<0.1 0.4 1.1

<0.1

<0.1 0.1 U/va spp.

<0.1 0.2 0.2 0.7

<0.1 Gaslroclon/um subart/culatum 0.3 0.7

<0.1

<0.1

<0.1

<0.1

<0.1 Mazzaella affinis

<0.1

<0.1 0.1 0.4

<0.1 0.2

<0.1 Cryptopleura violacea 0.1 0.4

<0.1

<0.1

<0.1 Cladophoraspp.

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 Chondracanthus cana/iculatus

<0.1

<0.1

<0.1

<0.1

<0.1 Mastocarp us lardinii

<0.1

<0.1

<0.1

<0.1

<0.1 Co/pomeniaspp.

<0.1

<0.1

<0.1 Plerosiphonia dendroidea

<0.1

<0.1

<0.1 Chiorophyta (filamentous)

<0.1

<0.1

<0.1 Invertebrate Counts Antho pleura e/egantiss/ma 253.8 366.1 236.4 264.8 234.6 355.8 197.0 261.2 230.5 Ch/orostomna funebralis 130.2 34.4 157.0 210.1 174.0 72.5 64.0 42.2 131.3 Tetrac/ita ru/bescens 49.4 96.0 9.0 20.1 0.2 0.4 3.6 8.0 15.6 Pagurusspp.

21.4 25.4 3.0 4.8 8.4 11.1 14.8 9.8 11.9 Lot//a scabra 3.6 4.2 6.2 7.2 8.6 2.5 14.6 10.5 8.3 Loll/a /limatu/a 6.4 7.8 5.4 5.8 5.4 5.8 1.6 1.5 4.7 Lollia pe/ta 2.2 2.8 3.0 2.5 1.4 1.7 1.0 1.0 1.9 Lollia sculum 2.8 4.7 1.2 2.2 2.2 2.4 0.6 0.9 1.7 Pachygrapsus crass/pes 0.6 0.9 2.0 1.2 3.0 1.6 1.0 1.2 1.7 Acanllhinuce/la spp.

0.8 0.8 0.6 0.9 1.2 2.2 0.4 0.5 0.8 Cirratulidae/Terebellidae 1.0 1.7 0.4 0.9 0.6 1.3 0.5 Fissure//a volcano 0.2 0.4 0.4 0.9 0.2 0.4 0.2 Cyanoplax spp.

0.4 0.5 0.2 0.4

<0.1

<0.1 0.2 Strongylocentrotus purpuratus 0.4 0.9 0.2 0.4 0.2 Lottiidae

<0.1 0.4 0.9

<0.1

<0.1

-0.1 Pisasfer ochraceus 0.2 0.4 0.2 0.4 0.1 Nemertea 0.2 0.4

<0.1 Octopus spp.

0.2 0.4

<0.1 Ocinebrina spp.

0.2 0.4

<0.1 Littor/na spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Epiton/um/Opalia spp.

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Hermissenda crass/corn/s

<0.1

<0.1

<0.1 (table continued)

'/

ESL0201 5-05 C-45

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C20 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 2+0.9m (11+3).

Survey...

176 177'..

17817

,Survey Date....

3-Jan-14

,29-Apr-14 24,JUn-14 :

5-Nov-14 t..,Std!

Std.

Std.,

AnnuaI Taxon

,Mean Dev."

Mean:

0!ev.

Mean,,Dev.:

Mean:

Dev.

Mean Invertebrate Counts (continued) lschnochitonidae

<0.1

<0.1

<0.1 Isopoda

<0.1

<0.1

<0.1 Barleeia spp.

<0.1

<0.1

<0.1 Modiolus spp.

<0.1 -

<0.1

<0.1 Mytilidae

<0.1

<0.1

<0.1 Mytilusspp.

<0.1

<0.1

<0.1 Invertebrate Cover Chthamalus fissus 4.0 3.9 2.2 2.2 2.8 2.3 4.4 5.7 3.4 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Phragmatopoma californica

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Substrate Cover rock 38.4 22.1 46.0 20.1 38.3 23.5 39.4 25.2 40.5 sand (shell gravel) 12.2 12.8 11.7 11.6 7.5 10.9 9.0 10.2 10.1 cobble 1.4 2.5 2.7 5.1 2.9 4.4 2.0 3.9 2.3

/'

ESLO2015-05 C4 C-46

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C21. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 3+0.3m (12+1).

.. Survey

.176 177 78 179 ;,

S' Survey Date '

10-Feb-44.

. 2-Jun-14.

..7-Aug-14 20-Nov-14 1

i, Std.

"Std.

Std.

oStd.

Annual

,Taxon,

...Mean Dev.*

Mean

,Dev. *;*Mean Dev.

Mean

'Dev.

Mean Algae Cover non-coralline crust Mastocarpus papillatus Endocladia muricata Gelidium coulteri Chondracanthus canaliculatus Cryptopleura violacea Mazzaella affinis Prionitis spp.

Gelidium pusillum Ulva spp.

54.8 22.1 0.2 0.7 1.0 2.4 0.2 0.7 0.1 0.4

<0.1

<0.1 0.1 0.4 0.2 0.7

<0.1 0.2

<0.1 0.2

<0.1'

<0.1

<0.1

<0.1 filamentous red algae complex coralline crust Corallina vancouveriensis Gastroclonium subarticulatum Cladophora spp.

Mazzaella leptorhynchos Colpomenia spp.

juv, articulated coralline algae Mastocarpus jardinii Chlorophyta (filamentous)

Invertebrate Counts Tetraclita rubescens Pa gurus spp, Chioro stoma funebralis Lottie scabra Strongylocentrotus purpuratus Ant hopleura elegantissima Lottie limatula Lottie pelta Fissurella volcano Chloro stoma brunnea Lottie scutum Pechygrepsus crassipes Petifia miniete Mytilus spp, Pisaster ochraceus Epiactis prolifere Serpulorbis squamigerus Lottiidae Diopetre ornate Urticina spp.

Ophiothrix spiculete Littorine sopi.

32.3 1.7 0.6

<0.1 0.1 0.1

<0.1

<0.1 0.3

<0.1

<0.1

<0.1

<0.1I 72.8 61.0 63.8 15.2 10.0 5.4 4.0 6.4 1.8 4.4 0.6 0.4 0.4 0.2 0.2

<0.1 27.7 3.0 1.6 0.2 0.4 0.4

<0.1

<0.1 0.7

<0.1

<0.1

<0.1 70.2 86.2 49.2 12.5 7.5 4.4 3.1 4.6 2.5 6.0 0.9 0.5 0.9 0.4 0.4

<0.1 47.7 20.5 4.9 7.7 0.8 2.0 2.0 3.4 0.2 0.7 0.1 0.4 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 53.8 16.5 3.8 4.9 0.7 2.0 0.1 0.4 1.2 2.8 0.9 1.6 0.3 0.6

<0.1 0.2 0.1 0.4

<0.1

<0.1 0.3 0.9

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 237.2 428.0 139.6 148.4 29.4 36.2 15.0 23.4 7.6 4.8 10.6 14.8 1.8 2.5 4.8 5.9 0.8 0.8 1.4 2.6 2.8 2.7 0.8 0.8 1.6 3.6 0.4 0.9 0.4 0.9

<0.1 0.2 0.4 0.2 0.4 47.2 2.6 0.6 0.6 0.5 0.3 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 186.4 58.4 57.0 18.1 13.2 6.7 5.0 4.3 3.6 2.1 1.9 1.0 0.4 0.4 0.2 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1 250.4 24.6 67.6 10.8 5.4 7.0 9.4 3.6 11.0 1.0 0.4 0.2 0.4

<0.1

<0.1

<0.1 420.7 12.7 85.5 7.2 4.4 8.5 3.6 2.7 7.4 0.7 0.5 0.4 0.9

<0.1

<0.1 185.2 8.4 67.0 31.4 29.6 3.8 4.6 2.2 0.8 2.4 3.0 2.2 1.0 0.4

<0.1 173.2 7.1 59.8 53.7 24.4 2.9 2.4 1.3 1.1 3.4 1.2 2.9 2.2 0.5 (table continued) a*'*ESLO2015-05 C-47

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C21 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 3+0.3m (12+1).

Survey 176 177 178 179 Survey Date 10-Feb-14 2-Jun-14 7-Aug-14 20-Nov-14 Std.

Std:

Std.

Std.

Annual Taxon Mean 0ev.

Mean 0ev.

Mean 0ev.

Mean 0ev.

Mean Invertebrate Counts (continued)

Pelecypoda boring

<0.1

<0.1I

<0.1

<0.1

<0.1 Cyanoplaxspp.

<0.1

<0.1

<0.1 Lottia gigantea

<0.1

<0.1

<0.1 Aliaspp.

<0.1

<0.1

<0.1 Epitonium/Opalia spp.

<0.1

<0.1

<0.1 Pugettia spp.

<0.1

<0.1

<0.1 Sipuncula

<0.1

<0.1

<0.1 Eratospp.

<0.1

<0.1

<0.1 Invertebrate Cover Chthamalus fissus 0.5 1.1 0.6 1.5 0.1 0.3 2.0 5.9 0.8 Phragmatopoma califormica

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Pista spp.

<0.1

<0.1

<0.1

<0.1

<0.1 Salmacina tribranchiata

<0.1

<0.1

<0.1 Substrate Cover rock "22.2 17.6 46.9 26.5 22.8 14.4

,14.9 13.2 26.7 cobble 18.7 8.0 18.0 8.6 17.1 11.7 18.0 10.5 18.0 sand (shell gravel) 1.7 3.0 0.4 0.7 3.3 3.3 3.2 3.6 2.2

~IIINuI'VESLO2015_05 C4 C-48

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C22. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 3+0.9m (12+3).

Survey 176 177 178 179 Std.

td.

td.

td.

nnua Survey Date 10-Feb-14 2-Jun-14 7-Aug-14 20-Nov-14 Taxon Mean 0ev.

Mean Dev.,

Mean Dev.

Mean Dev.

Mean Algae Cover non-coralline crust Mastccarpus papillatus Endocladia muricata Gelidium coulteri coralline crust Gelidium pusillum Corallina vancouveriensis Cladophora spp.

Mazzaella leptorhynchos Mazzaella affinis Prionitis spp.

Ulva spp.

juv. articulated coralline algae Invertebrate Counts Chiorostoma funebralis Anthopleura elegantissima Tetraclita rubescens Lottia scabra Lottia limatula Pa gurus spp.

Pachygrapsus crassipes Acanthinucella spp.

Lottia scutum Lottia pelta Ocinebrina spp.

Cirratulidae/Terebellidae Littorina spp.

Nemertea Serpulorbis squamigerus Romaleon antennarius Serpulidae Lottiidae Epitonium/Opalia spp.

Grapsidae Cyanoplax s pp.

Crepidula spp.

Isopeda Homolo. luridum/Lirularia succincta Invertebrate Cover Chthamalus fissus Spirorbidae Phraomatoo*oma califomnica 40.6

<0.1 1.2

<0.1 0.3 0.1

<0.1

<0.1

<0.1

<0.1 20.9

<0.1 2.3

<0.1 0.7 0.4

<0.1

<0.1

<0.1

<0.1 88.4 83.1 36.0 30.5 156.2 243.2 12.2 19.5 8.2 10.5 6.0 2.1 0.8 0.8 1.2 1.6 0.2 0.4 0.8 1.3

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.1 1.2

<0.1

<0.1

<0.1

<0.1 37.1 0.5 1.0 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 154.8 51.2 17.0 24.6 9.0 11.8 0.8 0.2 0.2 0.2 0.2

<0.1 0.2

<0.1 17.9 1.5 3.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 93.8 42.3 24.2 18.8 13.0 6.9 0.8 0.4 0.4 0.4 0.4

<0.1 0.4 47.8 23.6 1.9 4.0 1.0 2.6 0.6 1.1 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 170.2 23.8 3.2 39.0 6.0 5.8 3.4 1.6 0.8 0.6 0.2

<0.1

<0.1

<0.1

<0.1 81.8 34.0 5.2 31.4 7.1 4.3 1.8 1.5 1.1 0.9 0.4

<0.1

<0.1

<0.1

<0.1 36.6 3.2 1.3

<0.1

<0.1

<0.1 0.1

<0.1

<0.1

<0.1

<0.1 282.4 81.4 1.4 51.2 9.4 7.2 1.0 1.2 2.6 1.0 0.6 0.2 0.2 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1 12.8 3.8 3.5 0.2 0.2

<0.1 0.4

<0.1

<0.1

<0.1

<0.1 175.0 114.9 2.6 42.0 11.1 9.0 1.0 1.6 3.2 1.7 0.9 0.4 0.4 0.4 0.4 0.4

<0.1

<0.1

<0.1 40.5 1.4 1.1 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 174.0 48.1 44.5 31.8 8.2 7.7 1.5 1.1 1.0 0.7 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 2.7

<0.1

<0.1 2.3 3.2

<0.1

<0.1

<0.1

<0.1 3.3 3.1

<0.1

<0.1

<0.1

<0.1 4.2 3.9

<0.1

<0.1

<0.1

<0.1 (table continued) a'*ESLO2015-05 C-49

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C22 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in 2) survey means, standard deviations and 2014 annual means for South Diablo Cove Station SDC 3+0.9m (12+/-3).

Survey 176 177 178 179 Survey Date 10-Feb-14 2-Jun-14 7-Aug-14 20-Nov-14 Std.

Std.

Std.

Std.

Annual Taxon *Mean 0ev.

Mean 0ev..

Mean 0ev.=

Mean 0ev. ",Mean Substrate Cover rock 37.9 22.7 38.7 19.3 33.2 23.0 28.0 16.7 34.5 cobble 17.4 14.1 16.5 12.6 11.0 8.9 22.2 12.5 16.8 sand (shell gravel) 1.3 2.1 1.9 2.2 2.7 3.2 2.4 3.4 2.1 "S *ESLO2O15-05 C-50

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C23. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Point Station SDP l+0.9m (22+3).

Survey 176 177 178 179 Survey Date 11-Feb-14 13-May-14 25-Jun-14 4-Dec-14 Taxon Mean Dev.

Mean Dev.-

Mean Dev.

Mean Dev.~

Mean Algae Cover non-coralline crust coralline crust Ge/idium coulteri Corallina vancouveriensis Egregia menziesii juv. articulated coralline algae Mastocarpus jardinii Mazzae/la flaccida Cryptopleura violacea Calliarthiron/Bossiella spp.-complex Endoc/adia muricata Prionitis spp.

Ulva spp.

Mastocarpus papi/latus Ge/idium pusil/ur Ca/lit hamnion spp.IPleonospor, spp.

Chondracanthus cana/iculatus Porphyra spp.

Cladophora spp.

Mazzae/la affinis Scytosiphon spp.

Gastroc/on/um subarticu/atum Mazzael/la ore gona Laminariales Codiurn fragile subsp. ca/ifornicurn filamentous red algae complex Invertebrate Counts Tetraclita rubescens Anthop/eura elegantissima Strongylocentrotus purpuratus Lot/ia scabra Fissure/la volcano Lottia gigantea Lottia pe/ta Nutta//ina ca/ifornica Pachygrapsus crassipes Mytilus spp.

Pisaster ochraceus Anthopleura xanthcgrarmrica Lottia /irnatu/a Nemertea Chlorostorna brunnea 42.2 14.4 8.7 10.9 2.4 2.4 1.8

<0.1 0.6 0.3 0.7 0.6

<0.1

<0.1 0.2

<0.1

<0.1

<0.1 258.0 93.2 90.

8.6 6.2 5.4 1.6 1.0 0.6 0.4 0.2 0.8 0.6 0.8 23.3 5.8 5.5 7.7 2.8 1.5 1.5 0.2 1.1 0.6 2.0 0.8 0.2 0.3

<0.1

<0.1

<0.1 198.8 55.3 81.2 6.4 2.0 3.4 1.5 1.2 1.3 0.9 0.4 0.8 0.5 0.8 40.3 22.1 15.7 10.2 18.4 5.6 12.0 9.6 3.3 3.9 1.7 1.9 2.3 2.2 2.9 1.8

<0.1 0.2 2.7 3.2 0.7 2.2 0.3 0.5 0.6 0.9 0.2 0.5

<0.1

<0.1 0.2 0.3 0.1 0.4

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 252.6 175.1 259.2 364.5 71.6 49.2 33.8 24.3 3.4 3.6 4.4 4.4 3.6 1.5 0.6 0.5 1.0 0.7

<0.1

<0.1 0.4 0.9 0.6 0.5 0.6

'0.9 0.8 0.8 0.6 0.9 42.6 16.0 24.3 4.4 6.1 2.4 4.4 2.1 0.2

<0.1 1.3 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 114.4 69.4 27.6 18.6 3.4 3.6 5.8 0.8 3.6

<0.1 1.6 1.2 1.6 0.2 1.0 18.8 8.0 6.8 3.5 5.2 3.9 4.4 2.1 0.7 0.2 4.2 0.5 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 120.7 19.5 10.7 15.5 1.8 3.4 6.4 1.3 2.1

<0.1 0.5 1.3 0.5 0.4 2.2 38.3 13.7 6.7 11.9 1.6 3.8 1.1

<0.1 2.7 0.3 0.5 1.0

<0.1

<0.1

<0.1

<0.1

<0.1 315.0 96.4 59.4 69.0 23.8 9.0 6.4 6.8 2.2 6.2 2.0 1.2 1.0 1.0 0.4 17.6 7.0 3.8 8.0 1.5 2.3 1.1 0.2 5.3 0.5 1.5 1.0

<0.1

<0.1

<0.1

<0.1

<0.1 88.5 57.8 68.8 48.4 5.0 7.6 2.4 1.6 1.6 6.4 1.2 1.3 1.2 1.4 0.5 40.8 15.0 14.5 9.8 3.3 2.6 2.4 1.3 0.9 0.8 0.8 0.5 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 235.0 129.6 62.2 32.5 9.2 5.6 4.4 2.3 1.9 1.7 1.1 1.0 1.0 0.7 0.5 (table continued) a'W--ESLO2015-05 C-51

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C23 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Point Station SDP 1+0.9m (22+3).

Survey,,

176 177' i 78 79 Survey Date

' 11-Feb-14 1 3-May-14 25-Jun-14, 4-Dec-1'4

°..

S

.Std'. * *.

Std.

... Std.

Std, Annual Taxon Mean Dev.

Mean 0ev.

Mean...

Dev.

Mean 0 ev.

Mean Invertebrate Counts (continued)

Serpulidae 0.8 0.8

<0.1

<0.1

<0.1

<0.1 0.6 0.9 0.4 Leptasteuias spp.

0.4 0.5 0.8 0.8 0.3 Nucella spp.

0.4 0.9 0.2 0.4 0.2 Nereididae 0.2 0.4 0.2 0.4 0.1 Pagurus spp.

0.4 0.9

-0.1 Lottiidae

<0.1

<0.1

<0.1 0.2 0.4

<0.1 Cyanoplaxspp.

<0.1

<0.1

<0.1

<0.1 0.2 0.4

<0.1

<0.1

<0.1 Ha/lotis spp.

0.1 0.3 0.1 0.3

<0.1 Lottia scutum 0.2 0.4

<0.1 Chlorostoma funebralis 0.2 0.4

<0.1 Romaleon antennar/us 0.2 0.4

<0.1 lschnochitonidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Pollic/pes polymerus

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Sipuncula

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Pelecypoda boring

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Grapsidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Pycnogonida

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Lot/ia ochracea

<0.1

<0.1

<0.1

<0.1

<0.1 Pododesmus cepio

<0.1

<0.1

<0.1 Littorinaspp.

<0.1

<0.1

<0.1 Ophiuroidea

<0.1

<0.1

<0.1 Amphissa spp.

<0.1

<0.1

<0.1 Invertebrate Cover Phragmatopomacalifomica 0.5 1.1

<0.1

<0.1

<0.1 0.2 1.2 2.0 0.4 Chthamalus fissus

<0.1

<0.1

<0.1

<0.1 0.2 1.0 2.0 0.3 Dodecaceria fewkesi

<0.1

<0.1 0.1 0.4 0.3 1.1 0.3 0.7 0.2 Spirorbidae

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Sa/mac/na tribranchiata

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 Porifera (encrusting)

<0.1

<0.1

<0.1 Substrate Cover rock 7.0 7.1 1.7 1.3 1.8 1.8 3.3 5.2 3.4

  • ESLO2015-05 C-52

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C24. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Diablo Point Station SDP 2+0.9m (14+3).

...Survey....

176 177 17

.179, Survey Date 1Feb-,14 13-May-14.....

25-Jun-14 7-Dec-14 Taxon*

,Me'an*,,,

Dev.

Mean 0 ev.

Mean 0 ev.

.. Mean:

Dev.

'Mean Algae Cover corafline crust Corallina vancouveriensis Prionitis spp.

Gelidium coulteri Calliarthron/Bossiella spp.-complex Egregia menziesii Cryptopleura violacea Mazzaella flaccida juv. articulated coralline algae non-coralline crust Gastroclonium subarticulatum-Corallina chilensis Callithamnion spp.IPleonospor, spp.

Chondracanthus canaliculatus Mastocarpus jardinli Chondracanthus corymbifenus Osmundea spp.

Microcladia coulteri Desmarestia ligulata Mastocarpus papillatus Chrysophyta filamentous red algae complex Gelidium pusillum Lilva spp.

Microcladia borealis Bryopsis spp.

Callithamnion pikeanum Gelidium robustum Laminariales Mazzaella ore gona Porphyra spp.

Plocamiurn violaceum Codium fragile subsp. califomicum Macrocystis pyrifera Invertebrate Counts Antlhopleura e/egantissima Strongy/ocentrotus purpuratus Mytilus spp.

Tetraclita rubescens Fissurella volcano Pachygrapsus crassipes Chloro stoma brunnea Nuttallina californica Lottia scabra 21.9 6.8 18.5 8.6 6.7 9.7 8.1 7.7 3.1 5.1 3.7 6.1 3.7 1.7 2.4 1.1 2.0 1.2 4.6 1.5 1.1 1.9

<0.1

<0.1 0.5 0.9 0.3 0.8

<0.1

<0.1

<0.1'

<0.1

<0.1

<0.1 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 22.5 6.3 16.4 6.9 9.7 7.6 9.4 7.1 12.7 7.6 5.9 11.3 5.9 3.0 7.8 5.5 2.0 1.8 0.9 2.1 0.7 0.9 0.1 0.4 0.1 0.4 0.3 0.5 0.3 0.7 0.4 1.3 0.3 0.8 0.2 0.7

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 34.4 11.7 7.7 9.6 1.9 10.1 3.5 5.7 6.9 0.8 0.3 0.6 0.5 0.2 0.3 0.1

<0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 287.0 72.4 19.4 16.2 5.4 4.4 2.2 1.6 0.6 15.0 8.5 8.0 9.8 3.7 18.9 3.2 3.9 7.5 0.9 0.8 1.2 0.8 0.7 0.6 0.4

<0.1 0.4 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 278.8 47.6 38.4 17.4 0.9 0.5 2.6 3.6 1.3 27.9 9.8 14.9 8.6 5.8 7.7 1.5 1.2 3.0 3.6 0.8 1.1 3.4 3.0 0.5 0.7 0.1 0.4 0.6 1.1 0.2 0.7 2.0 4.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 26.7 15.4 7.5 7.1 5.2 5.1 4.1 4.1 2.3 2.0 0.6 0.5 0.3 0.3 0.2 0.2 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 351.7 137.7 49.8 32.6 5.6 2.7 2.4 2.2 2.0 267.4 183.8 12.6 39.4 6.2 1.8 2.4 2.4 3.6 196.5 102.5 27.1 36.4 4.1 0.8 2.3 2.3 7.0 438.4 149.2 12.0 48.6 5.2 2.8 1.8 2.2 3.8 334.7

.96.7 25.7 71.3 4.7 2.0 2.5 3.3 7.4 413.8 145.4 155.0 26.2 5.4 1.6 3.0 2.4 419.1 96.6 260.7 11.3 5.0 1.5 1.6 3.6 (table continued) 0W ESLO2015-05 C-53

It 81.L 0'£ 12'£ g'

VI' LI.'

  • 9 9'9

)jooi

.16AO3 a~eaqsqn£ 120>

'0 v>

v'0>

elzeJepeotuoo e!buodso~oeqds 120>

10>

1.0>

1.0>

V0>

1.'0>

1.0>

le!oos/punlodLuoo 'saeoiufl, 1,'0>

12'0>

12'0>

,'10>

12'0>

I,'0>

1,'0>

(Su~lsniouo) Bozo,£1q I,'0>

1.0>

1.0>

1.'0>

1.'0>

1.0>

1.0>

1.'0>

1.'0>

(Bu!lsfliouG) eleiliod 120>

1,'0>

v'0>

-'0>

v0>

v0>

v'0>

1'0>

e~e~qO~u~ewqJ uoeu~'9*

120>

,.0>

10>

1,.0>

1.0>

10>

eep~qioJ~d3 12O>

6'0

£'0 1.0>

1.0>

,'0>

1.0>

1'0>

eIoJ!u,!/oRW~odoleWfeJqld

1.
  • 0>

1.0>

1.0>

1.0>

9'.

['0 1.0>

1.0>

SnlSSIJ Snleu9le/QN

'0 6'0

£'0 8'0

£'0 t'0 1.0 VO 1.0

!se~lMeJ eueoeoepoa

.JaAO3 o e~sqq1.aAuI 1,'0>

10>

1.0>

6ep!sd2J$

1'0>

10>

1.0>

ddsmfe~lnd I,'0>

1.0>

1.0>

-sjqejsu!

eql-o-I,'0>

1.0>

1. 0>

dds eql 120>

,' 10>

1.0>

1,'0>

1.'0>

'dds e~siqduwV

'20>

1.0>

1.0>

1.0>

1.0>

eep!uoflPqou1PSl I,'0>

-O.>

1.0>

1.0>

1.0>

eJpw eawoV 120>

10>

1.0>

eeoeJpoo eIlJO'7 120>

1.0>

1.0>

1.0>

1.0>

1.0>

1.0>

1.0>

1.0>

eIlnound!S 120>

1.0>

1.0>

10>

1.0>

1.0>

1.0>

1.0>

Bu!Joq Bpod/Aoeled "20>

10>

10>

10>

10>

eep!lllo7

'20>

£'0 1.0

-£'0 1.'0

'dd SflolleH 1,'0>

O

  • '0

-SnIu6uuG!u9 UOeleWUO~'

12O>

V'0

  • '0 ddss*nin~ed 1,'0>

VO'

  • '0

-o~deo SnlWSSpopod L0>

v0

'090 V

8p!p!eJ8N 12'0

'0

~

-'0 v'

'0 "dds elledolA1

-'0 6"0 17'0 17'0

  • '0

-iJ!Ioid s!loe1d3

-'0 6"0 9"0

-17'0

  • '0 elnie*Uil efllo-

'0 1.1.

8"0 1.0>

1.0>

1'0

'0 t'0

  • '0 eleeUI elleO!UO.L L'0 Z'

1.0>

1.0>

1.'0>

1.0>

81.

8'0 sruewAXlod sed!OillOd 9"0 90 1'0

£'.

91.

6'0 Va' ea1JaUWON L'0 VO' 0

-'0 9";

91.
01. LddsOIlle~N 6'0 6'0 17'0 0'£
  • dds snueleg 0'I 8'0 8"0

£'.

6'0 9'0 eep!lndieS 12 1.1.

8"0 8"0 8"0 9'0 vo' snieB!uwenb ssiqiolndies 1I,'

I'0

  • '0
91.
11.
81.
81.

0'1.

01.,

"dd~sWOSO~eledO I,1,

£1'.

9'0 L'£ 0£

£'

8'0

-ejled eIllO'l 91.£'

8'4

£1'.

9"0 L1' V,'

91.

Q0" er~uweJL~oqluex eJneldoq~luv 6'

[1.'

7'*

9Z V'£ 6'0 9'0

£'

sneoeJqoo Jelses!tI (panu!, oo) S1UO u

owqaJe~pAUl ueOaJ

"^aa ueaN

'AOG uea*

"^AO ueaW

'aOG ueeaJ oe ienuuv

'pis "p*

'p]*

P 6LL 9LL LLL 9LI

  • aOAunl

"(E+vT) tu6"0+-;,dG£uoS U*l~

u~od olq1e!G 4qfnoS.Ioj sueOtU ~fntLI l40 pugr SUloI.TWAop p~rnpurs 'su~eitu,a{omns (tn 0" *od eouepunqe) smw~qalvoAu!

oI!;OTm pug (JoAO0 ;ueaied) semi:*sqns puie 'sOweJqapeIAU.i O[ISSeS 'o0"eI' 1p~.tvuI "(penu!uoo) lzj aiqgL se*,eJsqns pue se*,Jqe1JeAUl 'eG~V lepi;ie;Ul -

Oj x!pueddvi

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C25. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Control Station SC 1+0.3m (19+1).

Survey 176 177 J

178 179 Survey Date 14-Jan-14 1-May-14*

26-Jun-14 9-Oct-14 Std.

Std. IStd.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Algae Cover Mazzaella flaccida Chondracanthus canal/cu/atus Gastrocloniurn subarticulaturn Phyllospadix spp.

non-coralline crust coralline crust Prionitis spp.

Cryptopleura violacea Smithora naiadum juv. articulated coralline algae Coral//na vancouver/ens/s Mastocarp us lardninl Ulva spp.

Mazzaella affinis Mastocarpus papillatus Egregia rnenziesfi Osrnundea spp.

Mazzae/la ore gona Microcladia coulteri Mazzaella splendens Chondracanthus coyrymbiferus Ge/id/urn coulteri Callithamnion pikeanurn Gelidiurn pusi/lurn Endoc/adia rnur/cata Calliarthron/Bossie/la spp.-complex Halosaccion arnericanurn Desrnarestia ligulata Sarcodiotheca gaudichaudii Callophyl/is spp.

Halyrnenia/Schizyrnenia spp.-complex Cryptop/eura ruprech/iana Erythrophyllumn de/esserioides Cladophora spp.

Melobesia rnediocris Coral//na chilensis Mazzae/la leptorhynchos Porphyra spp.

Rhodophyta (juv. blades)

Invertebrate Counts Te/rac/ita rubescens Pa gurus spp.

Chlorostomna funebra/is 20.8 15.3 9.59 19.9 14.6 4.9 0.2 2.8 1.6 1.0 0.1 0.1 0.3

<0.1 0.1 0.3

<0.1 0.6 0.3

<0.1

<0.1 0.2

<0.1 12.8 12.0 11.2 15.6 12.9 8.9 4.1 3.3 0.5 2.8 2.1 1.5 0.4 0.3 0.7 0.2 0.4 0.7

<0.1 1.0 0.8

<0.1

<0.1 0.7

<0.1 34.4 22.8 6.9 12.4 8.4 12.1 5.1 1.9 0.2 3.1 1.6 0.7 0.8

<0.1 1.3 0.3 0.5 1.3 1.2 0.4 0.1 0.5 0.4 0.2 0.1

<0.1 0.1

<0.1

<0.1

<0.1 17.6 10.4 6.3 25.2 4.7 5.1 4.2 3.3 0.5 2.2 3.0 1.2 1.4

<0.1 2.6 0.9 0.7 1.0 1.3 0.9 0.4 0.7 1.1 0.5 0.4 0.2 0.4

<0.1

<0.1

<0.1 39.8 19.9 24.1 8.4 9.5 6.5 14.2 25.8 9.2 6.8 10.3 6.3 3.5 5.5 3.2 3.3 2.1 5.9 2.6 7.0 1.1 2.6 2.2 3.6 0.6 1.2

<0.1

<0.1 0.6 1.0 1.3 2.9 0.2 0.7 0.4 0.9

<0.1

<011 0.2 0.7

<0.1

<0.1 0.5 1.0 0.6 1.1

<0.1

<0.1 0.2 0.5 0.1 0.4 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 56.0 108.7 11.0 2.0 0.8 1.1 33.9 19.7 13.1 7.9 24.4 18.3 13.8 26.5 11.4 10.4 10.1 5.4 6.5 6.7 2.4 2.0 5.0 13.8 1.0 1.3 0.7 0.9 1.5 3.4 2.8 4.0 2.8 5.4 0.6 1.1 1.0 2.3 1.4 2.0 0.1 0.4 1.8 1.7 0.8 1.4 0.2 0.5 0.1 0.3 0.5 0.9 0.3 1.1 0.3 0.9 0.2 0.7

<0.1

<0.1

<0.1 0.2

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 32.2 19.9 14.0 12.5 12.2 11.8 5.0 3.1 1.8 1.7 1.6 1.5 1.3 0.7 0.7 0.7 0.6 0.5 0.5 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 63.1 6.8 6.0 140.8 108.5 7.4 6.1 6.4 5.0 20.6 17.6 3.0 2.4 5.4 11.0 34.8 48.1 5.8 4.2 11.4 12.5 (table continued) a'*ESLO2015-05 C-55

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C25 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 m2) survey means, standard deviations and 2014 annual means for South Control Station SC 1+0.3m (19+1).

Survey '!

176 177 178 '

179 Survey Date.

14-Jan-14 ~

, 1-May-14 26-Jun144,,

9-Oct-14 Taxon,

Mean Dev.

Mean, 0ev. ' Mean 0' ev.

Mean

  • Dev.

Mean Invertebrate Counts (continued)

Fissurella volcano Chl/oro stoma brunnea Loll/a scabra Lollia pelta Anthopleura elegantissima Loll/a scutum Loll/a limatula Epiactis prolifera Mo pa/ia spp.

Nemertea Leptasterias spp.

Tonicelia lineata Pugettia spp.

Balanus spp.

Oc/nebrina spp.

P/saster ochraceus Nereididae Call/ostoma ligature Pachygrapsus crassipes Serpulidae Chlorostoma monterey/

Romaleon antennarius Aptyxis luteop/ctus Cryptoch/ton stelleri Lottiidae Ischnochitonidae Lacuna spp.

Al/a spp.

Grapsidae Acmaea rn/tra Mytilus spp.

Homolo. lur/dumiL/rularia succ/ncta Crepidula spp.

Onchidella borealis Lireobitt/urn spp.

Lissothur/a nutr/ens Patiria miniata Amnph/ssa spp.

Sipuncula Barleeia spp.

Erato spp.

3.4 1.0 1.4 0.8 2.6 0.4 0.8 0.4 0.2 1.2 0.8 0.6 0.2 0.4 0.4 0.4 0.4 0.2 0.2 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 3.5 1.0 2.6 0.8 3.1 0.5 1.3 0.5 0.4 1.3 1.8 0.9 0.4 0.5 0.9 0.5 0.9 0.4 0.4 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.8 0.8 1.8 1.5 1.8 4.0 0.6 0.5 0.8 1.3 1.6 1.8 2.0 1.6 0.2 0.4 0.2 0.4 1.0 1.4

<0.1

<0.1 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.4 6.7 6.6 6.6 3.0 6.2 1.2 1.3 0.4 0.5 0.4 0.9 0.8 1.1 1.4 2.1 0.4 0.5 0.2 0.4 0.2 0.4 0.4 0.9 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 8.2 3.9 4.0 3.9 2.4 3.2 3.4 3.9 1.2 0.8 2.6 2.1 0.8 1.1 1.0 2.2 1.0 0.7 0.6 0.9 0.4 0.9 0.4 0.9 0.2 0.4 0.6 1.3 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 5.2 3.4 2.2 1.5 1.3 1.3 1.1 0.8 0.5 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued) a' ESLO2015-05 C-56

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C25 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Control Station SC 1+0.3m (19+1).

,,-;'...... Survey Date

  • Taxon,
  • *:o, Invertebrate Cover Phragmatopema califomnica Pista spp.

tunicates, compound/social Chthamalus fissus Spirorbidae Porifera (enorusting) bryozoa (encrusting)

Substrate Cover rook sand (shell gravel) cobble S 176.

  • i14-Jan-14 Std.

Mean *,Dew.

.177

,.,1-May-14,

.Std.

Mean

.Dev.,

178 26-Jun-14 Std.

Mean Dev.

9-Oct-14

Std, Mean 0ev.

Annual Mean*

I _________

16.1 14.5 1.0 3.1

<0.1

<0.1

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1 10.0 9.6 1.5 3.9 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 14.0 17.5 9.4 14.2 3.3 4.3 8.5 7.3 0.7 2.2 0.3 0.9

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 13.2 7.0 4.7 8.1

<0.1

<0.1 12.6 10.8 1.3 4.0 0.2 0.7

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 7.6 6.7 2.8 6.7 2.6 2.8 11.8 1.1 0.2

<0.1

<0.1

<0.1

<0.1 9.5 4.5 1.9 3.3 1.2 1.7 2.3 1.3 2.0 aESLO2O15-05 C-57

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C26. Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Control Station SC l+0.9m (19+3).

Survey 176 177 178 179 Survey Date 14-Jan-14 1-May-14 26-Jun-14 9-Oct-14 Std.

'Std;

Std, Std.

Annual Taxon Mean Dev.

Mean 0ev.

Mean 0ev.

Mean Dev.

Mean Algae Cover Silvetia cormpressa non-coralline crust Mastocarpus papillatus Endocladia muricata coralline crust Mazzaella flaccida Gelidium pusillum Mastocarpus jardinhi Fucus gardneri Corallina vancouveriensis Cryptopleura violacea Gelidium coulteri Chondracanthus canaliculatus juv. articulated coralline algae Mazzaella ore gona Mazzaella affinis Forphyra spp.

Mazzaella leptorhynchos Ulva spp.

Cladophora spp.

Callithamnion pikeanum Halosaccion americanum Hesperophycus califomicus Corallina chilensis Osmundea spp.

Invertebrate Counts Chiorostoma funebralis Tetraclita rubescens Lottia scabra Lottia scutum Pa gurus spp.

Lottia pelta Lottia limatula Anthopleura elegantissirna Ocinebrina spp.

Pachygrapsus crassipes Hemigrapsus nudus Siron gylocentrotus purpuratus Acanthinucella spp.

Leptasterias spp.

Nemertea Mopalia spp.

Chlorostoma brunnea 28.3 17.2 29.7 8.8 12.9 5.0 12.2 7.3 9.9 5.7 5.1 3.1 6.2 7.6 3.8 4.7 3.1 3.2 2.5 4.7 0.8 1.6 2.2 4.0

<0.1 0.2

<0.1

<0.1 0.3 0.6

<0.1

<0.1 0.3 0.9 0.1 0.4

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 120.6 84.9 154.2 307.0 27.0 46.2 4.4 2.8 11.8 8.3 1.8 2.5 3.2 3.0 2.6 2.7 0.2 0.4 0.4 0.5 0.4 0.5 1.2 1.8 0.2 0.4 22.6 10.9 18.1 9.2 16.1 8.8 13.7 6.4 12.6 7.1 9.4 8.3 1.9 1.0 2.6 2.1 3.5 2.8 1.3 1.5

<0.1

<0.1 0.5 0.9 1.0 2.1 0.6 1.2 0.1 0.4 0.2 0.5

<0.1 0.2

<0.1

<0.1

<0.1

<0.1 23.4 12.8 18.1 9.6 22.4 14.3 17.6 7.2 6.0 6.0 12.6 9.3 2.1 2.3 0.8 1.1 2.2 2.4 0.8 1.3 0.7 1.5 0.3 0.7 0.6 1.5 0.1 0.3

<0.1 0.2 0.1 0.4

<0.1

<0.1

<0.1

<0.1

<0.1 0.2 0.1 0.3

<0.1 0.2

<0.1

<0.1 107.4 106.3 20.2 27.3 3.8 3.9 4.2 2.9 2.6 2.1 2.0 2.4 3.8 3.2 1.2 0.8 0.2 0.4 0.6 0.5 0.2 0.4 0.2 0.4 29.0 14.8 16.1 9.9 26.9 18.6 11.2 10.3 10.4 6.8 9.7 7.7 3.5 3.1 6.2 6.3 2.6 1.8 0.8 1.3 2.8 4.8 0.2 0.3 0.9 1.7 0.1 0.4

<0.1

<0.1 0.3 0.9

<0.1 0.2

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 45.8 29.8 100.6 202.6 4.0 6.2 6.4 5.9 4.6 4.0 1.4 1.3 2.0 1.9 0.4 0.9 0.4 0.9 0.2 0.4 0.2 0.4 0.2 0.4 25.8 20.5 19.6 13.7 9.7 9.2 3.4 3.4 2.9 1.3 1.1 0.8 0.7 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 96.6 78.0 12.4 5.1 5.0 3.4 2.6 2.3 0.5 0.4 0.3 0.3 0.3 0.1

<0.1

<0.1

<0.1

.112.4 37.0 14.8 5.2 5.4 5.0 1.8 3.2 1.2 0.4 1.0 43.7 64.7 14.5 1.1 7.4 2.8 1.3 3.4 1.3 0.5 1.7 (table continued)

I ESLO2015-05 05 C-58

Appendix C - Intertidal Algae, Invertebrates and Substrates Table C26 (continued). Intertidal algae, sessile invertebrates, and substrates (percent cover) and motile invertebrates (abundance per 1.0 in2) survey means, standard deviations and 2014 annual means for South Control Station SC l+0.9m (19+3).

Survey 176 177 178 179 Survey Date 14-Jan-14 1-May-14 26-Jun-14 9-Oct-14 TaXon jMean 0ev.

Mean Dev.

Mean Dev.

Mean 0ev.

Mean Invertebrate Counts (continued)

Patiria miniata Pisaster ochraceus Pet rolisthes spp.

Idotea app.

Lottiidae Littorina spp.

Grapsidae Cyanoplax spp.

Crepidula spp.

Lottia instabilis Lacuna spp.

Mytilus spp.

0.2 0.4 0.2 0.4 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.8 1.3 0.5 1.0

<0.1

<0.1

<0.1.

<0.1 0.2 0.4

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.2 2.9

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 2.3 6.3

<0.1

<0.1

<0.1

<0.1 9.8 6.0 8.8 11.6 3.7 4.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.3 0.2

<0.1

<0.1 14.4 7.8 3.2 Invertebrate Cover Phragmatopoma californica Chihamalus fissus Spirorbidae Haliclona spp.

Substrate Cover rock cobble sand (shell gravel) 0.8 2.6 0.1 0.4

<0.1

<0.1 22.0 11.8 4.6 6.4 3.4 3.5 15.3 5.8 2.8 7.1 6.9 3.9 10.3 11.9 2.8 7.2 10.7 3.7

't*--ES LO2015-05 C-59

Diablo Canyon Power Plant Appendix D Intertidal Fishes

Appendix D - Intertidal Fishes Table D1. Intertidal fish survey totals, 2014 annual means, and standard deviations, North Control Station NC IV (N).

S, Survey 136' 137 138 139

..... Survey Date.

28-Jan-14 29-May1 11-Aug-14" 8-Dec-14'...

I...

A nnual

  • Std.

Taxon.

'Total T otal

'" Total..

Total Mean.....

Dev.

Xiphister mucosus 13 16 31 1

15.3 12.3 Xiphister atropurpureus 4

7 16 6

8.3 5.3 Pholidae/Stichaeidae 10 2

8

5.

6.3 3.5 Gobiesox maeandricus 2

2 6

3 3.3 1.9 Anoplarchus purpurescens 1

7 2

2.5 3.1 Cottidae 6

1 1.8 2.9 Gibbonsia spp.

1 2

-2 1.3 1.0 Cebidichthys violaceus 1

1 1

2 1.3 0.5 Oligocottus snyderi 2

-2 1

1.3 1.0 Apodichthys fucorum 3

-0.8 1.5 Artedius spp.

1 1

0.5 0.6 Oligocottus/Clinocottus spp.

1 0.3 0.5 Table D2. Intertidal fish survey totals, 2014 annual means, and standard deviations, Field's Cove Station FC 1V (C).

"Sure 136:

137 138 '

139

Suirvey Date I:28-Jan 27-May-14'.,

15-Jul-14' 22-Dec A nnual "

Std. "..

Taxon "Total

'Total Total Total' Mean...

.Dev,. :'

Cebidichihys violaceus 10 2

59 18 22.3 25.4 Xiphister mucosus 25 4

3 3

8.8 10.8 Pholidae/Stichaeidae 2

6 4

5 4.3 1.7 Anoplarchus purpurescens 3

6 2.3 2.9 Cottidae 1

6

-1 2.0 2.7 Xiphister atropurpureus 6

1 1.8 2.9 Oligocottus snyderi 1

4 1.3 1.9' Gobiesox maeandricus 2

1 0.8 1.0 Apodichthys fucorum 1

0.3 0.5 Atherinopsidae 1

-0.3 0.5 Table D3..Intertidal fish survey totals, 2014 annual means, and standard deviations, North Diablo Cove Station NDC 1V (L).

Sur ey*

136

,,137,, -

138 139

1.

....*-survey Date

,,'30-Jan-14 I14-May-14 10-JuM-4 24-Nov-14

' ' i, :...

,=, *,,

, J * :: °:,,, '

A n n u al..

S td...

Taxon Total:-

Total,
Total,
Total, Mean Dev,-.

Cebidichthys violaceus 1

5 1.5 2.4 Xiphister atropurpureus 2

-1 2

1.3 1.0 Xiphi ster rmucosus 2

-0.5 1.0 Oxyjulis californica

-1 0.3 0.5 8*'ESLO2015-05

,D-1

Appendix 0 - Intertidal Fishes Table D4. Intertidal fish survey totals, 2014 annual means, and standard deviations, South Diablo Cove Station SDC 2V (H).

  • Survey 136 137.

138.

139 Survey Date 30-Jan-14 16-May-14 11-Jul-14 Nov-14

Annual Std.

Taxon Total Total T lotal Total Mean 0 ev.

Cebidichthys violaceus 17 9

30 16 18.0 8.8 Xiphister atropurpureus 16 14 9

4 10.8 5.4 Xiphister rnucosus 12 2

3 2

4.8 4.9 Pholidae/Stichaeidae 2

3 3

7 3.8 2.2 Anoplarchus purpurescens 4

-4 5

3.3 2.2 Girella nigricans 1

0.3 0.5 Gobiesox maeandricus -0.3 0.5 Apodichthys fucorum 1

0.3 0.5 Table D)5. Intertidal fish survey totals, Station SC IV (S).

2014 annual means, and standard deviations, South Control Survey 136 137 138,

,,139 Survey Date 27-Jan-14 28-May-14

,8-Aug-14 22-Dec-14, Annual Std.

,Taxon *Total Total Total Total Mean Dey.

Porichthys not atus 250

-62.5 125.0 Anoplarchus purpurescens 11 5

24 10 12.5 8.1 Cebidichthys violaceus 17 10 11 9

11.8 3.6 Pholidae/Stichaeidae 7

16 7

11 10.3 4.3 Xiphister mucosus 12 2

10 1

6.3 5.6 Oligocottus snyderi 14

-3.5 7.0 Micrometrus aurora 6

-1.5 3.0 Cottidae 3

-1

-1.0 1.4 Apodichthys fucorumn 2

1

-0.8 1.0 Gibbonsia spp.

1 1

0.5 0.6 Xiphister atropurpureus

-1 1-0.5 0.6 Gobiesox maeandricus 1---0.3 0.5 Artedius spp.

1 0.3 0.5

  • L' ESLO2015-05 2

D-2

Diablo Canyon Power Plant Appendix E Subtidal Algae and Invertebrates

Appendix E - Subtidal Algae and Invertebrates Table El. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in2), standard deviations and annual means, Field's Cove Station PC 1 -3m (22-10).

Survey 164 165 166 167 1

Suvetdt.2-eb1 17-tn-1 22-JuM 6-JanAnnua Suetatd2eb1 17tJn-1 StdJl-6-Jan-15ua Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Algae Laminar/a setcheillii Pterygophora californica Cystoseira osmundacea Macrocystis pyrifera Nereocystis luetkeana Laminariales Egregia menziesii Invertebrates Chloro stoma brunnea Pa gurus spp.

Acmaea mitra Pa/jria miniata Strongylocentrotus purpuratus Tonicella lineata Cryptochiton stelleri Calliostoma ligatum Pugettia spp.

Chlorostoma montereyi Leptasterias spp.

Mitra idae Hal/otis spp.

Ophiothrix spiculata Serpulorbis squamigerus Diopatra ornata Anthopleura elegantissima Pseudomelatoma torosa Placiphore/la velata Cryptolithodes sitchensis Serpulidae Paraxant h/as taylori Urticina spp.

Fissure/la volcano Pomaulax gibbjerosa Henricia leviuscula Tethya californ/ana Doris spp.

Loxorhynchus spp.

Dor/opsilla albopunctata Fissure//idea bimaculata Ophioplocus esmarki Majidae Scyra acutifrons Mopalia spp.

Octopus spp.

Romaleon antennarius 21.8 6.5 5.5 0.8 0.5 0.3 8.9 3.4 3.1 1.0 1.0 0.5 111.8 25.9 0.5 1.0 5.3 2.9 4.3 0.5 2.3 1.5 2.5 1.0 1.5 1.7 2.3 1.7 1.5 3.0 0.5 0.6 0.5 0.6 0.8 1.0 0.8 1.0 0.8 0.5 0.8 1.0 0.8 1.0 0.8 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.5 1.0 0.3 0.5 0.5 1.0 0.3 0.5 18.5 6.0 8.0 5.5 7.3 1.3 0.5 0.6 0.5 1.0 0.5 0.6 0.3 0.5 83.3 15.0 9.0 6.7 4.5 5.2 4.3 1.3 2.5 2.7 1.5 1.7 1.0 0.8 0.8 1.5 0.8 1.0 0.8 1.0 0.8 0.5 0.5 1.0 0.8 1.5 0.5 0,6 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 11.3 7.6 10.0 6.2 5.8 2.1 0.3 0.5 0.3 0.5 92.3 72.7 8.8 5.7 7.5 7.1 4.5 1.3 1.3 0.5 0.8 1.5 1.8 1.7 0.8 1.5 1.0 0.8 0.8 1.5 1.3 1.5 0.8 1.0 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.5 0.6 0.5 1.0 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 8.3 4.0 7.0 3.7 6.0 3.6 14.9 7.9 6.1 0.4 0.3 0.2

<0.1 90.0 12.8 3.0 2.5 10.8 2.3 1.3 3.0 1.8 1.5 0.3 0.3 0.5 0.5 0.3 0.3 0.5 0.3 0.5 0.5 0.3 0.3 21.5 19.0 2.5 0.6 11.3 2.9 1.3 2.5 0.5 3.0 0.5 0.5 0.6 1.0 0.5 0.5 0.6 0.5 1.0 1.0 0.5 0.5 94.3 7.8 5.1 3.9 3.6 1.7 1.6 1.5 1.4 0.9 0.6 0.6 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1 (table cont/nued) a'IW*

ESLO2015-05 E-1

Appendix E - Subtidal Algae and Invertebrates Table El (continued). Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m ), standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).

S Survey 164 165 166 167 Survey Date 25-Feb-14 17-Jun-14 22-Jul-14 6-Jan-15 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean 0ev.

Mean Dev.

Mean Invertebrates (continued)

Pthidiana hiltoni 0.3 0.5

<0.1 Cucumaria spp.

0.3 0.5

<0.1 Eudistylia polymorpha 0.3 0.5

<0.1 Crassadoma gigantea 0.3 0.5

<0.1 Cadlina spp.

0.3 0.5

<0.1 Cycloxanthrops novemdentatus 0.3 0.5

<0.1 Hapalogaster cavicauda 0.3 0.5

<0.1 Mytilus spp.

0.3 0.5

<0.1 Ophiactis simplex 0.3 0.5

<0.1 aW

'ESLO2015-05E2 E-2

Appendix E - Subtidal Algae and Invertebrates Table E2. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in2), standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).

Sur...

.ey

1.

6'4 16...

5 166*

167 SSurvey Date 6-Jan:14.

,2-May-14' 1,:,

5-JulM4 6-Jan-15,

SStd.

.- Std.

Std.

Std.,

Annual,..

TaXon,

. Mean' Dev.

Mean 0 ev.,, Mean Dey... Mean

, Dev.

Mean Invertebrates Strongylocentrotus purpuratus 996.5 5.0 989.3 19.5 927.3 86.5 849.8 154.0 940.7 Ophiothrixspiculata 533.3 315.9 54.3 16.0 78.0 22.5 71.3 9.1 184.2 Anthopleura elegantissima 10.5 2.5 6.8 3.1 9.3 3.4 10.3 5.3 9.2 Serpulidae 3.3 3.3 8.3 5.9 3.3 0.5 3.7 Strongylocentrotus franciscanus 4.0 2.2 3.3 1.0 2.3 2.1 1.3 1.3 2.7 Acmaea mitra 1.5 1.7 0.8 1.5 0.6 Haliotis spp.

0.5 1.0 1.0 0.8 0.4 Serpulorbis squamigerus 0.5 0.6 0.3 0.5 0.5 0.6 0.3 Diopatra omata 1.3 2.5 0.3 Pafiria miniata 0.5 0.6 0.5 0.6 0.3 0.5 0.3 Placiphorella velata 0.8 1.0 0.3 0.5 0.3 0.5 0.3 Pelecypoda boring 0.8 1.0 0.5 0.6 0.3 Eudistylia polymorpha 0.3 0.5 0.5 1.0 0.5 0.6 0.3 Diodora spp.

0.5 0.6 0.5 1.0 0.3 Epiactis prolifera 0.8 1.0 0.2 Anthopleura artemisia 0.3 0.5 0.3 0.5 0.1 Anthozoa.-

0.5 1.0 0.1 Doriopsilla albopunct atea 0.3 0.5 0.3 0.5 0.1 Ophiactis simplex 0.5 0.6 0.1 Fissurella volcano 0.3 0.5

<0.1 Sabellidae 0.3 0.5

<0.1 Cucumaria spp.

0.3 0.5

<0.1 NqW ESLO2015-05 E-3

Appendix E - Subtidal Algae and Invertebrates Table E3. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 1n2), standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).

Survey.

..164 15 166 167

,Survey Date....

7-Jan-!4 2-May-14 28-Jul-14 6-Nov,14 Std.

Std.

Std.. '.

Std.:

,Annual Taxon...

I Mean

0.

.. ev.'

Mean 0ev.

,.Mean 02ev.

, Mean

,Dev.

, Mean Invertebrates Strongylocentrotus purpuratus 975.0 48.0 999.0 998.8 0.5 887.3 110.5 965.0 Ophiothrixspiculata 601.3 183.8 157.5 37.8 148.8 13.9 181.3 55.4 272.2 Anthopleura elegantissina 14.5 7.6 29.0 10.0 15.5 9.3 13.8 2.9 18.2 Strongylocentrotus franciscanus 7.0 3.2 4.8 2.5 6.3 1.7 3.5 3.1 5.4 Phragmatopoma califomnica 13.8 17.0 3.4 Serpulidae 2.3 1.3 6.3 2.5 3'.5 1.7 3.0 Eudistylia polymorpha 0.3 0.5 2.0 2.5 1.3 1.5 0.5 0.6 1.0 Acmaea mitra 0.8 1.5 0.8 1.5 2.3 2.9 0.9 Cucumaria spp.

2.0 2.5 0.5 Diodora spp.

0.5 0.6 0.5 0.6 0.3 Patiria miniata 0.5 0.6 0.3 0.5 0.3 0.5 0.3 Megathura crenulata 0.3 0.5 0.8 1.0 0.3 Serpulorbis squanmigerus 0.8 1.0 0.2 Tonicella lineata 0.8 1.5 0.2 Pelecypoda boring 0.5 1.0 0.3 0.5 0.2 Anthozoa 0.3 0.5

<0.1 Parastichopus spp.

0.3 0.5

<0.1 Haliotis spp.

0.3 0.5

<0.1 Doris spp.

0.3 0.5

<0.1

  • 'WESLO2015-05E-E-4

Appendix E - Subtidal Algae and Invertebrates Table E4. Suibtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in 2), standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).

Survey 164 165 166 167 Survey Date 5-Feb-14 9-May-14 16-Jul-4 11-Nov-14 Std.

Std. IStd.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Algae Cystoseira osmundacea Macrocystis pyrifera Plerygophora californica Sargassum muticum Invertebrates Strongylocentrotus purpuratus Ophiothrix spiculata Anthopleura elegantissima Acmaea maitra Serpulidae Chlorostoma brunnea Serpulorbis squamigerus Anthozoa Tethya califomiana Eudistylia polymorpha Cucumaria spp.

Pelecypoda boring Pugettia spp.

Doris spp.

Anthopleura artemisia Pa gurus spp.

Parastichopus spp.

Diopatra orn ala Patinia miniata Strongylocentrotus franciscanus Doriopsilla albopunctata Urticina spp.

Epiactis prolifera Loxorhynchus spp.

Phidiana hiltoni Mitra idae Crassadoma gigantea Megathura crenulata Pteropurpura festiva Tonicella lineata Chlorostoma montereyi Placiphorell/a velata Scyra acutifrons Kelletia kelletii Diodora spp.

Pododesmus cepio Halcampa decemtentaculata Haliots spp.

Nemertea Pomnaulax gibberosa 5.8 3.8 1.3 1.9 1.0 0.8 266.8 184.3 14.5 2.7 15.0 6.6 5.3 2.9 1.0 1.2 0.3 0.5 0.3 0.5 1.0 0.8 0.3 0.5 0.3 0.5 0.3 0.5 1.5 1.3 0.3 0.5 0.8 1.0 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 1.8 15.3 14.5 6.0 8.3 6.0 0.8 0.8 2.0 1.3 0.5 0.3 0.3 0.3 0.5 1.0 0.8 0.5 0.3 0.3 0.8 0.3 0.3 3.8 1.3 78.7 10.1 4.1 4.2 8.5 4.9 0.8 1.0 1.0 1.2 1.5 1.0 0.5 0.5 0.5 0.6 0.8 1.9 0.5 1.0 0.5 0.5 1.5 0.5 0.5 3.3 1.3 2.8 0.5 198.5 179.6 2.8 2.5 18.3 4.4 13.5 11.1 3.5 4.7 2.5 3.1 6.0 4.3 1.0 1.2 2.5 3.0 1.0 0.8 2.0 2.2 0.8 0.5 0.5 0.6 0.8 0.5 0.8 1.5 1.0 0.8 0.3 0.5 0.5 0.6 0.8 1.0 0.3 0.5 0.3 0.5 0.8 1.5 0.5 0.6 3.5 0.5 0.3 0.5 151.3 87.5 24.3 13.5 11.3 11.3 4.0 2.0 1.3 1.5 1.5 2.3 0.5 1.5 1.5 0.3 1.3 0.5 0.8 1.0 0.5 1.0 0.3 0.5 0.5 0.3 0.5 0.5 0.3 0.5 0.3 0.3 3.3 0.6 0.5 0.6 107.7 36.2 8.5 3.0 6.7 7.1 2.5 2.3 1.9 1.3 1.3 2.9 0.6 0.6

_1.3 0.5 1.3 0.6 1.0 1.4 0.6 0.5 0.6 0.6 0.5 0.6 0.6 0.5 1.0 0.5 0.5 4.6 1.2 0.3 0.1 178.3 30.0 18.0 9.6 5.8 4-3 1.9 1.5 1.2 1.2 1.1 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1

<0.1

<0.1 (table continued)

VAWESLO2015-05 E-5

Appendix E - Subtidal Algae and Invertebrates Table E4 (continued). Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 rn ), standard deviations and annual means, North Diablo Cove SainNC4-m(9-15).

SSurvey 164 165 166 167 Survey Date 5-Feb-14 9-May-14 16-Jul-4 11-Nov-14 Std.

Std; Std.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean 0ev.

Mean Dev.

Mean Invertebrates (continued)

Hermiissenda crassicomis 0.3 0.5

<0.1 Ophioplocus esmarki 0.3 0.5

<0.1 Lophopanopeus spp.

0.3 0.5

<0.1 Navanax inermis 0.3 0.5

<0.1 Pandalus spp.

0.3 0.5

<0.1 a'*ESLO2015-05 E-6

Appendix E - Subtidal Algae and Invertebrates Table E5. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in 2), standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).

Survey 16 1="'

65

166=,....

167 Survey Date 6-Feb-14 1i2-May-14.....

7-AUg-I4 4-Nov-14 Annual

.Std

  • Std. I

,Std..

Std.

  • A n a Taxon Mean 0

oev.

Mean 0ev.

Mean

0.

ev, Mean

  • Dev..

Mean Algae Cystoseira osmundacea Pterygophora califomnica Macrocystis pyrifera Laminaria setchelilii Sargassurm muticum Invertebrates Ophiothrix spiculata Diopatra ornala Acmaea mitra Chiorostoma brunnea Anthopleura ele gantissima Pista spp.

Serpulidae Cucumaria spp.

Patiria miniata Anthopleura artemisia Anthozoa Serpulorbis squamigerus Mitra idae Pa gurus spp.

Doris spp..

Doriopsilla albopunctata Pugettia spp.

Fissurella volcano Tonicella lineata Strongylocentrotus purpuratus Phidiana hiltoni Eudistylia polymorpha Pteropurpura festiva Nemertea Loxorhynchus spp.

Pelecypoda boring Crassadoma gigantea Norrisia norrisi Diodora spp.

Mopalia spp.

Hermissenda crassicomnis tunicate, solitary Parastichopus spp.

Modiolus s pp.

Kelletia kelletii 5.8 2.6 3.8 4.3 1.5 1.3 0.3 0.5 0.3 0.5 56.3 25.3 17.3 20.0 3.0 4.2 2.8 1.3 1.5 1.3 0.5 0.6 2.0 0.8 0.8 0.5 0.5 1.0 0.5 0.6 0.8 0.5 1.0 2.0 0.5 1.0 0.5 1.0 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.3 0.5 0.3 0.5 6.5 0.8 0.8 1.5 3.7 1.5 0.5 3.0 1.3 1.8 0.8 1.5 2.4 0.5 2.0 1.3 0.3 2.2 1.3 0.5 1.5 1.7 2.3 2.9 2.8 1.9 2.3 2.6 0.8 1.0 0.3 0.5 1.0 0.8 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 4.8 3.4 4.8 2.1 9.8 6.7 12.8 13.9 2.8 2.2 3.8 2.6 3.5 2.5 5.0 3.7 1.8 1.3 1.8 1.3 2.3 1.7 2.3 2.1 2.0 0.8 0.5 1.0 0.3

.0.5 0.3 0.5 0.8 1.0 0.8 1.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 1.3 1.5 7.8 10.8 12.8 4.5 10.5 10.5 3.8 1.5 5.5 3.4 4.0 1.6 1.5 1.3 0.3 0.5 2.0 1.4 2.3 1.3 1.0 1.2 1.3 1.3 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 3.9 1.9 0.8 0.4

<0.1 15.9 7.4 6.9 5.8 3.0 2.3 2.3 1.8 1.6 1.3 1.1 1.0 0.6 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0,1 I* 'ESLO2015-05E-E-7

Appendix E - Subtidal Algae and Invertebrates Table E6. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in2), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).

.Surve*y' 164 165.

1 166.

.167 Survey Date:

24-Feb-14 2-Jun-14 :

17-Jul-14, 5-Nov-14,,

I:

  • Std.

Std.

.Std.

Std.

Annual Taxon Meain "'Dev.;

Mean

" Dev.'

Mean 0ev:

Mean.

0 ev. 4 Mean Algae Macrocystis pyrifera Cystoseira osmundacea Plerygophora californica Laminaria setchellii Invertebrates Anthopleura elegantissima Diopatra omata Patiria miniata Strongylocentrotus purpuratus Anthozoa Acmaea mitra Mitra idae Corynactis californica Serpulidae Anthopleura artemisia Serpulorbis squamigerus Tethya californiana Leucilla nuttingi Eupentacta quinquesemita Doris spp.

Pa gurus spp.

Cryptochiton stelleri Eudistylia polymorpha Urticina spp.

Chlorostoma brunnea Ophioplocus esmarki Pugettia spp.

Hermissenda crassicornis Doriopsilla albopunctata Ophiothrix spiculata Pisaster giganteus Scyra acutifrons Tonicella lineata Octopus spp.

Mimulus foliatus Crassadoma gigantea Sabellidae Strongylocentrotus franciscanus Loxorhynchus spp.

Pelecypoda boring Cucumaria spp.

Anthopleura xanthogrammica Pododesmus cepic Halcamoa decemtentaculata 1.3 1.0 1.5 1.3 2.5 3.7 33.3 9.7 25.5 21.8 15.8 3.8 12.5 4.4 7.5 3.9 2.5 2.1 1.0 0.8 1.5 1.3 1.3 0.5 1.5 0.6 0.3 0.5 0.3 0.5 1.0 0.8 0.5 1.0 0.5 0.6 0.8 1.5 1.3 1.9 1.3 1.5 0.5 1.0 0.5 0.6 0.3 0.5 0.3 0.5 0.8 1.5 0.3 0.5 0.5 0.8 0.5 0.6 0.3 0.5 0.3 0.5 2.0 1.5 1.0 1.3 2.0 23.0 9;8 12.3 7.8 14.0 2.2 4.5 4.7 4.5 3.7 1.5 3.0 4.8 4.6 6.3 1.9 2.3 1.0 1.5 0.6 4.8 7.6 3.8 2.5 0.5 0.6 0.3 0.5 1.0 1.4 1.3 2.5 0.5 1.0 0.5 1.0 0.5 0.6 0.3 0.5 0.3 0.5 3.3 1.5 2.0 1.4 0.5 0.6 15.5 5.2 12.8 12.4 12.8 1.0 5.8 9.6 7.3 2.6 1.5 1.7 7.5 5.1 9.8 14.2 1.5 1.7 1.0 2.0 4.3 1.7 2.3 1.3 2.3 1.5 1.0 0.8 0.5 1.0 0.3 0.5 0.5 0.6 0.5 1.0 0.5 1.0 0.3 0.5 0.3 0.5 1.5 1.3 1.3 0.3 1.3 1.5 1.9 0.5 21.5 5.9 16.0 11.4 5.5 1.3 7.5 10.0 8.3 4.1 6.8 4.5 1.5 0.6 2.0 0.8 0.8 1.0 0.5 0.6 0.5 0.6 1.8 1.0 0.3 0.5 0.8 1.0 0.5 0.6 0.8 1.5 0.5 1.0 0.3 0.5 0.8 1.0 0.5 0.6 0.8 0.5 0.5 0.6 0.5 1.0 2.0 1.6 1.3

<0.1 23.3 16.6 12.0 7.6 5.0 4.3 4.1 2A4 2.2 1.7 1.6 1.4 1.2 0.9 0.9 0.8 0.7 0.7 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1 (table continued) 8W

  • ESLO2015-05 E-8

Appendix E - Subtidal Algae and Invertebrates Table E6 (continued). Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m ), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).

urvey:

D at..

24-Feb-*14 *:

2-sJun-14 17-Jul14 5-NovJu4

_Taxon_.....

  • i.

,, Meani 4, Dev*.

Mi:*

ean,, ;..

Dev.::*

Mean:

Dev. :

D~~~an*:

'iiev.,:,Mean'*

Invertebrates (continued)

Cryptolithodes sitchensis 0.3 0.5

<0.1 Ceratostona foliatum 0.3 0.5

<0.1 Haliotis spp.

0.3 0.5

<0.1 Norrisia norrisi 0.3 0.5

<0.1 Cadlina spp.

0.3 0.5

<0.1 Aplysia spp.

0.3 0.5

<0.1

'w "ESLO2015-05E-E-9

Appendix E - Subtidal Algae and Invertebrates Table E7. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in2), standard deviations and annual means, South Control Station SC 1 -3m (19-10).

°,

SurveY 1,;64 165 166 "167 Survey Date

' "4-Apr-14 ;

18-Jun-14 12-Aug-14..

8-Dec-14 Std.,.

Std :.

,Std.

, o.

.Std. I Annual TaXon Mean Dev..,Mean 0ev.

Mean 0

eV.,.

Mean 0ev. j Mean Algae Pterygophora californica Cystoseira osmundacea Laminaria setchellii Laminariales Invertebrates Chlorostoma brunnea Patinia miniata Pa gurus spp.

Diopatra ornata Tonicella lineata Acmaea mitra Anthopleura elegantissima Calliostoma lgatume Pugettia spp.

Cryptochiton stelleri Cirratulidae/Terebellidae Chlorostoma montereyi Serpulorbis squamigerus Strongylocenitrotus purpuratus Lottia instabilis Leptasterias spp.

Mopalia spp.

Mitra idae Mimulus foliatus Serpulidae Anthopleura artemisia Henricia leviuscula Doriopsilla albopunctata Hali otis spp.

Doris spp.

Epiactis prolifera Diodora spp.

Romaleon antennarius Placiphorella velata Urticina spp.

Fissurella volcano Pododesmus cepio 28.3 15.0

  • 20.0 5.7 25.0 8.5 202.5 47.6 14.3 1.3 2.3 1.0 6.0 6.5 3.8 4.5 3.0
  • 1.4 1.5 1.7 3.5 2.5 2.3 1.3 1.5 3.0 1.5 1.0 0.5 0.6 0.5 1.0 0.5 0.6 0.8 1.5 1.3 0.5 0.5 0.6 0.8 0.5 0.8 0.5 0.5 0.6 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 25.8 25.0 21.3 7.5 52.5 20.8 14.5 8.8 6.0
  • 4.5 3.3 1.5 3.0 1.8 0.8 1.3 1.5 0.3 0.5 0.5 0.8 0.3 0.5 0.8 0.3 0.3 0.5 0.5 0.3 0.3 4.2 5.0 7.4 15.0 21.4 4.0 1.9 7.5 8.1 1.7 1.7 3.0 1.4 1.7
  • 1.0 1.3 0.6 0.5 0.6 0.6 0.5 0.5 1.0 1.5 0.5 0.5 1.0 1.0 0.5 0.5 29.5 17.3 25.5 4.5 58.5 5.8 0.5 1.3 3.8 3.8 3.3 0.8 0.3 1.0 0.8 0.3 2.3 0.3 0.5 0.3 0.5 0.3 0.3 0.3 0.5 0.3 29.3 3.3 7.3 3.8 22.0 1.7 0.6 1.5 2.9 1.5 1.7 1.5 0.5 0.8 1.5 0.5 1.3 0.5 0.6 0.5 0.6 0.5 0.5 0.5 0.6 0.5 22.3 8.7 32.5 7.1 21.0 2.7 2.3 2.6 180.0 82.7 2.0 1.6 6.0 5.4 7.0 5.6 2.3 1.5 1.5 1.7 3.3 1.5 5.3 10.5 0.5 0.6 1.3 1.3 5.0 10.0 1.5 1.7 1.3 0.5 0.5 1.0 0.3 0.5 0.5 0.6 1.3 1.0 0.3 0.5 1.0 1.2 0.5 1.0 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 26.4 23.7 23.2 3.6 123.4 10.7 5.3 4.8 4.5 3.4 3.2 2.3 1.8 1.6 1.3 0.9 0.9 0.6 0.6 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1 Halcampa decemtentaculata

,Pseudomelatoma torosa Cucumaria spp.

Cryptolithodes sitchensis Scyra acutifrons Pomaulax gibberosa Diaulula sandiegensis Maiidae 0.3 0.5 (table continued) 8W ESL02015-05E-0 E-IO

Appendix E - Subtidal Algae and Invertebrates Table E7 (continued). Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in 2), standard deviations and annual means, South Control Station SC 1 -3m (19-10).

Survey Date 4-Apr-14 :

  • 18-Jun-14 12-Aug-14

,8-Dec-14 Std,'.

Std "...

.. Std,.

Std.

Annual, Taxon Mean
  • Dev.

Mean Dev.,.

Mean Dev.

Mean...

Dev.

Mean Invertebrates (continued)

Lophopanopeus spp.

0.3 0.5

<0.1 Okenia rosacea 0.3 0.5

<0.1 Lepidozona spp.

0.3 0.5

<0.1 Eupentacta quinquesemnita 0.3 0.5

<0.1 Cadlina spp.

0.3 0.5

<0.1 Metridium senile 0.3 0.5

<0.1 1IUPhI ESLO2015-05 E-11

Appendix E - Subtidal Algae and Invertebrates Table E8. Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 in2), standard deviations and annual means, South Control Station SC 2 -6m (20-20).

S rvey.

164:.

165 166

...167

'=.

.. Suvey Date

.... 2'5-Mar-14:i 3-Jun-1i4,

, 23-Jul-14, 2.Jan-15..

Std,

,Std.

Std.

S, td. I Annual Tax*on,

Mean

, 'Dev.

Mean Dev:.

Mean Dev..

Mean Dev.

Mean Algae Pterygophora california 37.0 13.3 32.3 6.4 30.5 6.6 29.8 8.3 32.4 Laminaria setchellii 18.0 8.8 9.5 4.1 8.8 3.6 5.0 2.2 10.3 Cystoseira osmundacea 8.8 1.0 8.0 2.0 6.0 2.2 10.0 3.9 8.2 Laminariales 1.0 1.2 5.0 4.8 1.5 1.9 1.9 Nereocystis Iuetkeana 0.3 0.5 0.8 0.5 0.3 Invertebrates Chlorostomabrunnea 66.8 30.6 75.0 16.4 67.5 15.6 110.3 24.9 79.9 Patiriaminiata 25.3 13.0 12.5 7.6 15.5 6.5 7.0 5.2 15.1 Acmaea mitra 9.8 2.9 21.0 12.7 6.0 6.0 4.5 1.7 10.3 Calliostoma ligature 3.8 1.5 8.3 2.9 4.5 1.7 12.0 4.2 7.1 Serpulorbis squamigerus 27.3 5.2 6.8 Diopatra ornata 4.0 5.4 6.5 6.5 8.3 6.4 4.3 3.3 5.8 Anthopleura elegantissirna 4.5 1.3 5.8 3.5 7.0 2.5 1.5 0.6 4.7 Mitra idae 0.5 1.0 2.8 1.5 1.8 1.0 2.0 0.8 1.8 Lottia instabilis 2.0 0.8 1.3 1.3 3.5 1.9 1.7 Cryptochiton stelleri 1.0 0.8 2.3 1.9 1.5 2.4 1.0 0.8 1.4 Tonicella lineata 0.8 1.5 1.5 1.7 0.8 1.5 1.5 1.7 1.1 Chlorostona montereyi 1.5 1.7 1.5 1.7

-0.8 1.5 0.8 1.5 1.1 Doriopsilla albopunctata 0.8 0.5 1.0 1.2 2.0 2.8 0.3 0.5 1.0 Tethya californiana 1.3 1.9 0.5 0.6 1.0 1.4 0.8 1.0 0.9 Strongylocentrotus purpuratus 0.5 1.0 0.8 1.0

-2.0 0.8 0.8 Haliotis spp.

0.5 1.0 0.5 1.0 0.8 1.5 1.5 1.9 0.8 Eupentacta quinquesemita 0.5 1.0 0.3 0.5 1.5 0.6 0.5 0.6 0.7 Urticina spp.

0.5 0.6 0.8 1.0 0.3 0.5 0.8 1.0 0.6 Lottia insessa 2.0 0.8 0.5 Pomnaulax gibberosa 0.3 0.5 0.3 0.5 0.8 1.5 0.8 1.0 0.5 Pagurus spp.

0.5 0.6 0.3 0.5 0.5 0.6 0.8 1.0 0.5 Doris spp.

'0.8 1.0 0.5 1.0 0.8 1.0 0.5 Crassadorna gigantea 0.5 0.6 0.5 1.0 0.5 1.0 0.3 0.5 0.4 Pisaster/Henricia spp. (juv.)

0.3 0.5 0.3 0.5 1.0 1.2 0.3 0.5 0.4 Leptasteuias spp.

0.5 0.6 0.8 1.0 0.3 0.5 0.4 Diodora spp.

0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 Placiphorella velata 0.3 0.5 0.8 1.5 0.3 Cucumaria spp.

0.5 0.6 0.5 0.6 0.3 Eudistylia polymnorpha 0.3 0.5 0.5 0.6 0.3 0.5 0.3 Epiactis prolifera 0.3 0.5 0.3 0.5 0.1 Pisastergiganteus 0.3 0.5 0.3 0.5 0.1 Scyra acutifrons 0.3 0.5 0.3 0.5 0.1 Anthopleura artemisia 0.3 0.5

<0.1 Mopalia spp.

0.3 0.5

<0.1 Promnartynia pulligo 0.3 0.5

<0.1 Pisaster ochraceus 0.3 0.5

<0.1 Pycnopodia helianthoides 0.3 0.5

<0.1 Loxorhynchus spp.

0.3 0.5

<0.1 Diaulula sandiegensis 0.3 0.5

<0.1 (table continued) a

, ESLO2015-05 E-12

Appendix E - Subtidal Algae and Invertebrates Table Eg8 (continued). Subtidal algae and invertebrates (SAQ Method) survey means (abundance per 7 m ), standard deviations and annual means, South Control Station SC 2 -6m (20-20).

Survey 164 165 166 167 Survey Date 25-Mar-14 3-Jun-14 23-Jul-4 2-Jan-15 Std.

Std.

Std.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Invertebrates (continued)

Ophiop/ocus esmarki 0.3 0.5

<0.1 Pugettia spp.

0.3 0.5

<0.1 Lepidozona spp.

0.3 0.5

<0.1 Pachycheles spp.

0.3 0.5

<0.1 Megathura crenulata 0.3 0.5

<0.1 Cadlina spp.

0.3 0.5

<0.1 IqEEE* ESLO2015-05E-3 E-13

Diablo Canyon Power Plant Appendix F Subtidal Algae

Appendix F - Subtidal Algae Table Ft. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).

Surveyi 16

!4 i*

165 166

, T 167 Survey Date

25Feb-14 1

7-Jun-14 22-Ju1-14 6-Jan-15S

.Std,.

  • *Std, Std.* /

Std.

Annual Taxon°

Mean, Dev.

,Mean

.0ev.

Mean Dev;,

Mean Dev.

Mean Algae Calliarthron/Bossiella spp.-complex coralline crust Chondracanithus cor ymbiferus Cryptopleura ruprechtiana Rhodymenia spp.

Gelidium robustum non-coralline crust Cystoseira osmundacea Prionitis australis Neoptilota spp.

Prionitis spp.

Farlowia!Pikea spp.-complex Microcladia coulteri Leminaria setcheliji Pterygophora califomnica Macrocystis pyrifera Callophyllis spp.

  • Rhodophyta (juv. blades)

Halymnenia/Schizymen. spp.-complex Ahnfeltiopsis linearis Osmundea spp.

Nereocystis luetkeana Corallina chilensis Laminariales Mazzaella splendens Egregia menziesii Callophyllis flabelluata Scinaia con fusa Pterosiphonia dendroidea Antitham./Pterotham. spp.-complex Substrates colonized rock colonized cobble cobble sand (shell gravel) rock 53.0 49.0 10.0 9.0 8.0 4.5 4.5 1.0 5.0 2.0 0.5 0.5 1.0 2.0 0.5

<0.1

<0.1 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 63.5 15.5 1.5 1.5 6.0 3.5 4.3 2.6 5.4 4.4 3.4 1.2 1.2 1.6 1.0 1.0 2.0 2.3 1.0

<0.01

<0.01 1.0

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 9.9 8.2 3.0 1.0 66.0 49.0 19.0 14.5 8.5 7.0 2.5 4.0 2.5 3.0

<0.1

<0.1 2.5

<0.1 1.0 0.5 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 69.5 11.5 1.0 5.9 6.0 4.8 7.4 3.4 3.8 3.0 2.8 3.0 2.6

<0.01

<0.01 1.9

<0.01 1.2 1.0 1.0

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 7.0 7.2 1.2 55.0 44.0 11.0 15.0 6.0 3.5 1.5 5.0 2.5 2.5

<0.1 3.0

<0.1

<0.1

<0.1 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 62.0 17.0 3.0 5.3 10.7 3.5 3.5 3.7 4.4 1.9 3.8 3.8 1.9

<0.01 2.6

<0.01

<0.01

<0.01 1.0

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 7.3 9.6 2.6 54.0 14.3 33.5 8.2 4.0 2.8 3.0 3.5 2.0 1.6 4.0 3.7 5.5 1.9 1.5 1.0

<0.1

<0.01 0.5 1.0 3.5 1.9

<0.1

<0.01

<0.1

<0.1

<0.1

<0.01 66.5 8.7 8.5 5.5 6.0 4.3 1.0 2.0 57.0 43.9 11.0 10.4 6.1 4.8 3.5 2.9 2.5 2.0 1.0 0.9 0.9 0.5 0.4 0.3 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 65.4 13.1 2.9 0.4 0.3 IW ESLO2015-05F-F-1

Appendix F - Subtidal Algae Table F2. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).

S ::

Survey,,,

164 6:',

,l5 166 le I

167

] :

.....Survey Date

,6-Jan-14 2-May-14 15-Jul1,4 6.Nov-14

,Std.

Std."

Std.

Std.

,Annual Taxon:

M"

ean, De~v.

'Mean

Dev,

..Mean Dev'.

Mean Dev.

Mean Algae coralline crust 27.5 10.1 43.5 12.7 46.5 7.6 42.5 9.6 40.0 non-coralline crust 9.0 7.4 11.0 10.5 8.5 5.7 6.0 2.8 8.6 Chrysophyta 10.5 6.6 2.6 Ectocarpales 0.5 1.0 1.5 1.9 0.5 Calliarthron/Bossiella spp.-complex

<0.1

<0.01 0.5 1.0

<0.1

<0.1

<0.01 0.1 Chiorophyta (filamentous)

<0.1

<0.01

<0.1

<0.01 0.5 1.0 0.1 Rhodophyta (juv. blades)

<0.1

<0.01

<0.1 Substrates colonized cobble 19.0 14.3 26.0 11.0 30.0 6.7 29.5.

10.9 26.1 colonized rock 19.0 9.3 29.5 9.2 24.5 10.0 30.5 5.7 25.9 rock 32.0 8.3 19.5 5.5 17.0 3.8 14.0 7.1 20.6 cobble 12.0 6.9 7.0 6.0 6.5 1.9 7.0 5.3 8.1 sand (shell gravel) 3.5 3.4 0.5 1.0 1.0 Table F3. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).

"i; Survey Date 7-J~an-;14 2-May-1*4, 28-Jul1!4 ° 6-Nov-14,:

i:...,

=

.:Std...

Std.

,Std.

Std.

Annual

-Taxon, Mean,° Dev.

Mean, Dev.

,Mean, 0ev.

,Mean,

.Dev,.

Mean Algae coralline crust 38.0 5.9 52.0 7.3 48.5 4.1 49.0 4.2 46.9 Chrysophyta 12.5 2.5 3.1 non-coralline crust 3.0 2.6 3.0

.1.2 1.5 1.9

<0.1

<0.01 1.9 Ectocarpales

<0.1

<0.01 0.5 1.0 0.1 Chlorophyta (filamentous)

<0.1

<0.01

<0.1

<0.01 0.5 1.0 0.1 Calliarthron/Bossiella spp.-complex

<0.1

<0.1

<0.01

<0.1

<0.1

<0.1 filamentous red algae complex

<0.1

<0.01

<0.1 Substrates colonized rock 22.5 7.2 29.5 6.6 27.0 2.6 38.0 4.9 29.3 rock 34.5 9.4 20.5 4.1 25.5 2.5 13.5 6.6 23.5 colonized cobble 18.5 6.6 25.5 1.9 23.0 4.2 23.0 7.0 22.5 cobble 6.5 4.1 5.5 2.5 4.0 1.6 6.0 1.6 5.5 sand (shell gravel) 1.0 2.0 2.5 2.5 0.5 1.0 1.0 a*W' ESLO2015-05 F-2

Appendix F - Subtidal Algae Table F4. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).

Survey 164 165 166 167 Survey Date 5-Feb-14 9-May-14 16-Jul-4 11-Nov-14 Std.

Std. jStd.

Std.

Annual Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean 0ev.

Mean Algae corallinie crust Calliart hron/Bossiella spp.-complex Acrosorium ciliolatum Cryptopleura violacea Farlowia/Pikea spp.-complex filamentous red algae complex Prionitis spp.

Chondracanthus corymbiferus Rhodymenia spp.

Ectocarpales Chiorophyta (filamentous)

Desmarestia ligulata Cystoseira osmundacea Cryptopleura ruprechtiana Chondracanthus Ge/idiurn robustumn non-coralline crust Macrocystis pyrifera Halymenia/Schizymen. spp.-complex Chrysophyta Plerosiphonia dendroidea Nienburgia andersoniana Ahnfeltiopsis linearis Colpomenia spp.

Rhodophyta (juv. blades)

Plerygophora ca/ifornica Fryeel/a gardneri Osrnundea spp.

Laminariales Sargassum mnuticumn Laminar/a setchel/ii Coral/ina chilensis Microc/adia cou/teri Opuntiella califomica Sarcodiotheca gaudichaudii Polyneura latissima Fauchea laciniata Gloiosiphonia califomica Mazzaella splendens 51.0 6.2 23.0 6.2 16.5 8.2 2.5 1.9 11.0 4.8

<0.1

<0.01 3.5 2.5

<0.1

<0.01 5.0 7.6 3.5 4.1 1.0 2.0 0.5 1.0 3.0 2.6 0.5 1.0 1.0 1.2

<0.1

<0.01

<0.1

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 0.5 1.0 37.0 4.2 30.0 8.5 14.5 7.2 10.0 7.8 11.5 7.2 23.0 6.2 5.0 4.2 5.0 3.5 4.0 4.6 10.0 6.7

<0.1

<0.01 6.5 10.5 0.5 1.0

<0.1

<0.01

<0.1

<0.01 2.0 2.8 0.5 1.0

<0.1

<0.01

<0.1

<0.01 1.0 2.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 62.0 5.9 8.5 5.0 11.0 4.8 39.0 7.4 28.5 11.5 25.0 7.4 25.0 8.9 7.5 3.0 4.0 5.4 7.0 8.9 8.0 1.6 1.5 1.9 4.0 3.3 5.0 10.0 5.0 3.8 4.0 4.6 4.5 3.4 2.0 4.0 0.5 1.0

<0.1

<0.01 0.5 1.0 1.0 2.0 0.5 1.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 62.0 10.1 11.5 7.2 8.5 4.1 47.5 4.4 22.0 7.5 22.5 5.0 7.5 1.9 11.0 3.8 2.0 2.3 11.0 4.8 4.5 4.4 5.0 3.8 3.5 4.1 0.5 1.0 2.0 2.8 0.5 1.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 4.5 3.0 68.5 7.0 11.0 6.0 1.0 2.0 1.5 1.9 43.6 25.9 19.6 11.3 10.3 7.3 6.6 4.4 3.9 3.5 3.0 2.9 1.5 1.1 1.0 0.9 0.9 0.3 0.3 0.3 0.3 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 1.3 63.6 11.5 6.0 0.8 Invertebrates Phragmatopoma ca/ifomica Substrates colonized rock colonized cobble sand (shell gravel) cobble 62.0 15.0 3.5 1.5 6.7 4.2 4.4 1.9 I 'ES LO201 5-05F-F-3

Appendix F - Subtidal Algae Table F5. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).

Survey 164 165 166 167 Stdy.ae

-eb1 2

tdy-1 7-Ag-1 St-NoAnnua Suvytaed.eb1 12-My-1 7-Ag-1 4-Nov-14ua Taxon Mean Dev.

Mean Dev.

Mean Dev.

Mean Dev.

Mean Algae coralline crust 40.0 6.5 35.0 9.6 28.5 9.6 43.5 12.2 36.8 Cryptopleura violacea 13.5 3.4 51.5 5.3 59.5 9.6 15.5 1.9 35.0 Rhodymenia spp.

17.5 3.0 10.0 7.5 12.5 5.3 23.5 9.9 15.9 Calliarthron/Bossiella spp.-complex 9.0 7.0 14.5 13.0 12.0 9.1 14.5 5.3 12.5 Farlowia/Pikea spp.-complex 5.0 2.8 13.0 3.5

.5.0 1.2 12.0 5.2 8.8 Nienburgia andersoniana 5.0 2.6 10.0 7.8 4.0 2.3 11.0 7.0 7.5 Prionitis spp.

8.5 2.5 2.0 2.3 1.0 1.2 8.0 2.8 4.4 Cystoseira osmundacea 4.5 4.1 3.0 2.0 3.0 3.8

<0.1

<0.01 2.6 Acrosorium ciliolatum 0.5 1.0 5.5 4.7 3.0 2.0 2.3 Chondracanthus corymbiferus 1.0 1.2

<0.1

<0.01 3.0 2.6 3.0 2.6 1.8 Rhodophyta (juv. blades) 4.5 3.4 1.0 1.2 1.4 Macrocystis pyrifera 1.0 2.0 0.5 1.0 2.5 3.8

<0.1

<0.01 1.0 Ahnfeltiopsis linearis 2.0 2.3

<0.1

<0.01

<0.1

<0.01 1.0 1.2 0.8 filamentous red algae complex 2.5 3.8

<0.1

<0.01 0.5 1.0 0.8 non-coralline crust 1.0 2.0

<0.1

<0.01

<0.1

<0.01 1.0 2.0 0.5 Chondracanthus 1.5 1.9 0.5 1.0

<0.1

<0.01 0.5 Pterosiphonia dendroidea 2.0 2.8 0.5

'Gelidium robustum 1.0 2.0

<0.1

<0.01 0.3 Sarcodiotheca gaudichaudii 1.0 2.0

<0.1

<0.01 0.3 Callophyllis flabellulata 0.5 1.0

<0.1

<0.01

<0.1

<0.01 0.1 Cryptopleura ruprechtiana

<0.1

<0.01 0.5 1.0 0.1 Desmarestia ligulata

<0.1

<0.01 0.5 1.0 0.1 Chlorophyta (filamentous) 0.5 1.0 0.1 Pterygophora californica

<0.1

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1 Corallina chilensis

<0.1

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1 Osmundea spp.

<0.1

<0.01

<0.1

<0.01

<0.1 Gelidium spp.

<0.1

<0.01

<0.1

<0.01

<0.1 Laminariales

<0.1

<0.01

<0.1

<0.01

<0.1 Sargassumn muticum

<0.1

<0.01

<0.1

<0.01

<0.1 Laminaria setchellii

<0.1

<0.01

<0.1 Plocamiumnpacificum

<0.1

<0.01

<0.1 Antitham./Pterotham. spp.-complex

<0.1

<0.01

<0.1 Substrates colonized rock 51.5 2.5 52.5 3.8 56.0 5.9 56.0 7.5 54.0 sand (shell gravel) 14.0 2.8 19.5 8.7 22.5 5.7 12.5 9.0 17.1 cobble 9.0 2.6 4.0 1.6 2.5 1.9 7.0 2.6 5.6 colonized cobble 7.5 3.8 6.0 4.9 0.5 1.0 6.5 4.1 5.1 rock 0.5 1.0 0.1

'¢ ESLO2015-05 F-4

Appendix F - Subtidal Algae Table F6. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).

Survey 164" 165*

166

  • 167

.. Survey Date

"*24-Feb-14 2-Jun-14 17-Jul-14 5-Nov-14°-

Std.

,Std;,.

Std.

Annual Taxon Mean

,Dev.

,Mean

, Dev. jMa ev en D.

Ma Algae coralline crust Calliarthron/Bossiella s pp.-complex Rhodymnenia spp.

Cryptopleura violacea Cryptopleura ruprechtiana Chondracanthus corymnbiferus Farlowia/Pikea spp.-complex Macrocystis pyrifera Acrosorium ciliolatum Nienburgia andersoniana Ahnfeltiopsis linearis Cystoseira osmundacea Callophyllis flabellulata Prionitis spp.

Rhodophyta (juv. blades) filamentous red algae complex Polyneura Iatissima Ectocarpales Corallina chilensis Pterygophora californica non-coralline crust Rhodoptilum plumosum Laminaria setchellii Pterosiphonia dendroidea Antitham./Pterotham. spp.-complex Callophyllis spp.

Plocamium pacificum Osmundea spp.

Fauchea laciniata Prionitis australis Weeksia spp.

invertebrates Porifera (encrusting)

Phragmatopoma californica Substrates colonized rock sand (shell gravel) colonized cobble cobble 40.5 8.1 28.5 6.0 15.0 7.4 3.5 3.0 2.5 1.9 5.0 3.5 6.0 5.7 3.5 5.7 3.5 3.0 0.5 1.0 0.5 1.0 1.0 1.2

<0.1 1.5 1.9 1.0 2.0 0.5 1.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 45.0 35.5 24.5 11.0 10.0 6.5 7.5 4.5 2.5 1.0 1.5 0.5 2.5

<0.1

<0.1 0.5 0.5

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 10.0 5.3 12.9 3.5 1.6 3.4 1.9 1.9 1.9 2.0 3.0 1.0 2.5

<0.01

<0.01 1.0 1.0

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 1.0 5.2 3.0 2.5 4.8 44.0 3.7 39.0 3.5 15.5 10.1 16.5 1.9 8.5 4.1 5.5 2.5 5.5 1.9 8.0 1.0 2.0 1.5 1.9

<0.1

<0.1

<0.01

<0.1

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 0.5 1.0 52.0 9.8 29.5 10.3 15.5 6.0 5.0 4.2 4.0 2.8 8.0 4.3 3.0 1.2 6.0 3.7 0.5 1.0 3.0 2.6 3.5 3.0 2.5 2.5

<0.1 0.5 1.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 0.5 1.0 45.4 33.1 17.6 9.0 6.3 6.3 5.5 5.5 1.9 1.5 1.4 1.0 0.6 0.5 0.3 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.3 0.1 68.6 7.0 3.9 2.5 0.5 68.5 1.9 7.0 4.2 4.0 4.3 2.5 1.9 70.0 4.5 4.5 3.0 68.0 8.5 4.0 1.5 3.7 1.9 1.6 1.9 68.0 8.0 3.0 3.0 5.9 3.3 2.6 2.0

'ESLO2015-05 F-5

0 Il) 03 01 0"1

&1 0)

Ci)

O~C-)Th~~oo0C)

~

0000

~

~-~-c~

~

CD

~

~

N N.-.-

~

a--~-

fl-CD cDCD CD~

~

CD CD 0.

0~ CD 0

~

2CD

~.

OC 0n~-.~----O 0)0

~

coo 0

'~'~~-0W

~

~

0

~.

~

0-0 E3~0 0-.

0

~

0 CDCD2Oot~w CDCD

~

C

~

~

CD~

CD0~0~0CcmCD0o 000 0

~

~

~

0 0..0~

0

~

CD2-~

o,~,

000

0.

~0002 0

~

o 0

CD 00 0

~-

2 0

CDCi) 82

~

2 0-

0) 0-0 *0

-~

0 0

)C o

0 0

-~

2

~-

  • 0 CD

)<

CD CD 'C A

A A

A

-~-0--0)

CD

~

-~

C)

C)

C)C)C)C)C)C)C)C)C~)-JC)0)-.J w

.~

0u0C)C) ci, S

-S-CiCn-..~CnC)C)C5S0SC)0~C)~C)0~

~

~.

a~

.7

.CD.

A A

A A

C)

C)

C)

C)

-~

C)01C)N)

C),

0.5

-~

-~C)C)--~C)N)C)C)C)0)4).--~K0) 5P A

A A

A A

A A

A A

A A

-a.-a.-0)Aa CD C)0)05C)

Ca)

C)

C)C)C)

C)C)

C)C)C)C)

-0)-~0)~-J oWo,~C)

0)

C)

-~

sr

~

C)C)C)~C)C)O)

.~

C~

-~

=

0)

~

01 A

A A

A A

A A

A A

A C)

C)

C)

C)

C)

C)

C)

C)

C)

C)

CD.-.-

C)

CDC)C)

CrC)

C)

C)C)C)~C~'

05

-~

,sss

~-'

-~

~

0)

A A

A A

A A

A A

A

~

CD

-a.01 C)

C)

C)

C)

C)C)C)C)C)C)-~CIcoC0--.)

w

~

>-a.

0)

Co 0)

A A

A A

A A

A A

b

~

~C)C)

~~-Ca)-0)-)c00)

CD.-.-

001C)C)

C)C0

-~

-~

-~

-~

~

C)-a.N)--J0)0)C.a)C)

-a.

A A

A A

A A

A A

A A

A A

-a.0)-D-CD

-~0)N)Ca)

N)

C)

C)C)C)C)C)

C)C)C)

C)C)C)C)C)C)-a.-a.C)C)0)COC)--J

~

00 CD C)

-J A

A A

A A

A A

A A

A A

A C)

C)C)C)C)C)

C)C)C)

C)C)

C)

-"-a.

C)

CD.-..

N)N)C0~

~

~

(0

-~

~-~-'-

C)-"-~C)C)-a.N)0C)C)0,Ca)N)0)

C0~

AAAAAAA AAAAAA A

9)

~

~CI1 o ~

~9)

~1 09)

CtI 9)

~CD CD 0

I

-~

CD 9)9) 0 CD

~1 0CD 9) 00 CD

-5 0

9)9) 0-9)

'~1 0-9)-

CD 9) 9)

0 9) 9)0-9)9) 9)9) 9)

-o

-o CD 0~

5<

-I, Cl) 00~

9) 9)

CD

Appendix F - Subtidal Algae Table F8. Subtidal algae (SLC Method) survey means (percent cover), standard deviations and annual means, South Control Station SC 2 -6m (20-20).

Sure 164.

165 16 167; SUrveyDate 2*5-Mar-14

3-Jun.14 23-Jul-14:

2-Jan-15 Std.

Std.

[

St*d.'

Std.

Annual Taxon Mean Dev.

,,Mean 0ev. jMean 0 ev.

Mean 0ev.

Mean Algae coralline crust Calliarthron/Bossiella spp.-complex Cystoseira osmundacea non-coralline crust Plerygophora californica Rhodymenia spp.

Desmarestia ligulata Laminaria setchellil Cryptopleura ruprechtiana filamentous red algae complex Rhodophyta (juv. blades)

Callophyllis flabellulata Aleoptilota spp.

Fauchea laciniata Dictyota bin ghamiae Pterosiphonia dendroidea Rhodoptilum plumosum Fryeella gardneri Nereocystis luetkeana Weeksia spp.

Callophyllis spp.

Chondracanthus co rymbiferus Pugetia firma Opuntiella califomica Polyneura Iatissima Laminariales Ulva spp.

Dictyoneurum califomicum Gelidium robustum Scinaia con fusa Phaeophyta Farlowia/Pikea spp.-complex Invertebrates Phragmatopoma ca/ifomica Porifera (encrusting)

Corynactis califomnica bryozoa (encrusting)

Balanophyllia elegans Serpulorbis squamigerus tunicates, compoundlsocial bryozoa (erect)

Substrates colonized rock colonized cobble sand (shell gravel) cobble 51.0 5.3 31.5 14.6 5.5 3.0 4.0 3.3 3.0 2.6 2.5 3.0 2.0 1.6 1.0 1.2 2.5 3.0

<0.1

<0.01

<0.1

<0.01 1.0 1.2

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 3.5 4.1 2.5 3.0 1.0 2.0 1.5 1.0 0.5 1.0 52.0 4.9 38.0 10.2 6.5 4.1 4.5 1.9 3.0 2.0 5.5 1.0 3.0 3.5

<0.1 1.5 3.0 1.5 3.0 2.0 2.3 1.5 3.0 1.0 2.0 1.0 2.0 0.5 1.0 0.5 1.0

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 53.

41.

i10.

4.

2.

1.

3.

2.

1.

1.(

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

<0.

0 9.6 0

8.7 0

5.9 0

5 2.5 5

1.9 0

4.8 5

1.9 0

2.0 0

2.0 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 1

<0.01 5

5.3 5

1.9 0

2.3 0

1.2 5

1.0 5

1.0 0

6.3 0

5.9 5

1.0 5

1.0 60.5 9.2 41.5 16.4 6.5 6.4 3.5 5.7 4.5 1.0

<0.1 0.5 1.0

<0.1

<0.01

<0.1

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01

<0.1

<0.01 3.5 1.9 74.5 7.7 3.5 3.0 3.0 3.8 1.0 1.2 54.1 38.0 7.1 4.0 3.3 2.4 1.5 1.3 0.9 0.6 0.6 0.5 0.4 0.3 0.3 0.3 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 3.5 1.6 1.4 0.6 0.3 0.1 0.1 0.1 72.9 5.5 2.8 0.9 2.5 2.5 2.5 0.5 0.5 73.5 5.5 2.5 0.5 3.0 3.0 1.9 1.0 1.0 5.5 3.4 3.8 1.0 4.,

1.,

2.(

1.(

0.,

0.,

72.

8.

1.

0.

71.5 5.0 4.0 1.5 7.7 4.8 2.8 1.0 ESL0201 5-05F-F-7

Diablo Canyon Power Plant Appendix G

,Subtidal Invertebrates

Appendix G - Subtidal Invertebrates Table G1. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).

,Survey l64 165 166 167 T

....- SurveY Date

... 25-Feb-14

>17-Jun-14

,;22-Jul-14
6-Jan-15 I
  • Std.

Std..

Std.,

Std.

Annual TaonMean Dev.

Mean Dev.

Mean, Dev.
  • Mean

' DeV.~

Mean Invertebrate Counts Homolo. luridum/Lirularia succincta Chloroestoma brunnea Pa gurus s pp.

Phragmatopoma californica Pelecypoda boring Amphissa spp.

Pugettia spp.

Lissothuria nutriens Alia spp.

Serpulidae Strongylocentrotus purpuratus Chaetopteridae Leptasterias spp.

Pisaster/Henricia spp. (juv.)

Fissurella volcano Dendropoma spp.

Corynactis califomica Acmaea mitra Serpulorbis squamigerus Ocinebrina spp.

Romaleon antennarius Aptyxis luteopictus Pseudomelatoma torosa Cancridae Eulithidium spp.

Anthopleura elegantissima Anthozoa Calliostoma ligature Patinia miniata Mitra idae Lirobittium spp.

Mimulus foliatus Scyra acutifrons Sipuncula Epiactis prolifera Tonicella lineata Crepidula spp.

Hipponix spp.

Ophiothrix spiculata Cucumania spp.

Strongylocentrotus spp.

Calliostoma annulatum Diodora son.

3.8 5.0 5.5 3.9 5.8 4.1 4.5 3.3 7.3 13.2 1.0 1.2, 2.8 1.0 1.8 1.7 0.8 1.0 0.5 1.0 0.5 0.6 0.3 0.5 1.8 3.5 1.5 3.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.8 1.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 4.3 2.6 3.0 1.4 2.8 1.7 4.0 2.2 1.5 0.6 1.3 1.9 1.3 0.5 2.3 1.3 0.3 0.5 0.8 1.0 1.3 2.5 0.8 1.0 0.8 1.5 0.5 0.6 0.8 1.0 0.5 0.8 0.3 0.5 0.8 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 6.0 6.1 2.5 1.7 4.5 3.0 0.8 1.0 2.0 1.4 0.5 1.0 0.5 0.6 0.3 0.5 0.8 1.0 0.5 1.0 1.3 1.3 0.3 0.5 0.3 0.5 0.5 0.8 0.5 0.6 0.3 0.5 1.0 2.0 0.5 0.6 0.8 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 6.0 4.3 5.3 2.1 2.5 1.3 3.0 1.4 0.3 0.5 1.5 1.3 1.3 1.0 1.3 0.5 1.0 0.8 1.5 1.7 1.3 1.9 1.3 1.5 0.5 1.0 1.0 0.8 0.3 0.5 0.5 0.6 0.5 0.6 0.3 0.5 0.5 0.6 0.3 0.5 0.8 1.5 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 0.5 1.0 5.0 4.1 3.9 3.1 1.9 1.5 1.4 1.2 1.1 0.8 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1 (table continued)

I ESLO2015-05G1 G-1

Appendix G - Subtidal Invertebrates Table G1 (continued). Subtidai invertebrates (SFQ Method) survey means (abundance per 0.25 in 2; percent cover) standard deviations and annual means, Field's Cove Station FC 1 -3m (22-10).

survey '

164

.165 166 167,:

Survey Data*

25-Feb-14 17-Jun-14

'22-JuM-4

  • "6-Jan-15 Std.

Std.

.Std.

Std.

Annual Taxon'

?

Mean Dey.

' Mean 0ev.

Mean 0 ev*."

Mean~ D:ev.:

Meain Invertebrate Counts (continued)

Mopalia spp.

0.3 0.5

<0.1 Lottia instabilis 0.3 0.5

<0.1 Lottia ochracea 0.3 0.5

<0.1 Epitonium/Opalia spp.

0.3 0.5

<0.1 Loxorhynchus spp.

0.3 0.5

<0.1 Ischnochitonidae 0.3 0.5

<0.1 Placiphorella vielata 0.3 0.5

<0.1 Ophiuroidea 0.3 0.5

<0.1 Cryptolithodes sitchensis 0.3 0.5

<0.1 Heptacarpus spp.

0.3 0.5

<0.1 Aeolidia papilloaa 0.3 0.5

<0.1 Lophopanopeus spp.

0.3,

0.5

<0.1 Lepidozonia spp.

0.3 0.5

<0.1 Invertebrate Cover Balanus/Tetraclita spp.

1.2 1.8 0.8 1.4 1.9 3.0 1.1 1.9 1.2

  • Porifera (encrusting) 1.9 1.2

<0.1 0.1

<0.1 0.1

<0.1

<.01 0.5 bryozoa (encrusting) 1.0 1.4 0.1 0.3

<0.1 0.1 0.3 0.3 tunicates, compound/social 0.3 0.4

<0.1

<0.1

<0.1 0.1

<0.1 Spirorbidae

<0.1.

0.1

<0.1

<.01

<0.1

<.01

<0.1

<0.1 Salmacina tribranchiata

<0.1

<.01

<0.1 8*ESLO2015-05 G-2

Appendix G - Subtidal Invertebrates Table G2. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, North Diablo Cove Station NDC 2 -3m (8-10).

SSurvey 164 165 166*

167

  • Surv~ey Date,

6-Jan-14;

2-May-14St 15-Jul-4

.,6-Nov-14 Std.,

Std'..

.. Std.'

Std.*

Annual Taxon Mean Dev.

Mean Dev.

Mean

,Dev.

Mean,

Dev.

Mean Invertebrate Counts Strongylocentrotus purpuratus 49.8 11.9 37.0 18.0 40.8 14.1 25.3 11.5 38.2 Pelecypoda boring 23.5 19.6 24.3 19.3 15.8 11.7 7.8 6.3 17.8 Phragmatopoma californica 9.0 5.3 9.5 6.2 4.3 5.1 3.3 1.5 6.5 Ophiothrix spiculata 4.3 2.6 1.8 1.0 5.0 2.2 3.5 3.7 3.6 Ophiactis simplex 5.3 4.0 0.8 1.5 5.3 5.7 3.3 2.9 3.6 Serpulidae 1.3 1.3 2.3 1.5 2.5 3.0 0.8 1.0 1.7 Sipuncula 0.5 0.6 1.0 0.8 4.5 2.1 0.5 0.6 1.6 Anthopleura elegantissima 0.8 1.5 1.0 2.0 1.8 2.4 2.8 3.4 1.6 Fissurella volcano 2.3 0.5 1.0 1.4 1.0 0.8 1.0 1.2 1.3 Cirratulidae/Terebellidae 3.0 2.6 0.8 Anthozoa 0.3 0.5 1.5 1.3 0.5 0.6 0.6 Lottia ochracea 0.8 1.0 1.0 1.4 0.5 0.6 0.6 Sabellidae 0.8 1.5 0.5 0.6 0.3 0.5 0.4 Lottiidae 0.5 0.6 0.3 0.5 0.5 1.0 0.3 Epiactis prolifera 0.3 0.5 0.3 0.5 0.5 0.6 0.3 Placiphorella velata 0.8 1.0 0.3 0.5 0.3 Lissothuria nut riens 0.3 0.5 0.8 1.0 0.3 Podychaeta 0.3 0.5 0.5 0.6 0.2 Amphissa spp.

0.5 1.0 0.3 0.5 0.2 Haliotis spp.

0.5 1.0 0.3 0.6 0.2 Acmaea rnitra 0.3 0.5 0.3 0.5 0.1 Diodora spp.

0.5 0.6 0.1 Serpulorbis squamigerus 0.3 0.5 0.3 0.5 0.1 Pista spp.

0.3 0.5 0.3 0.5 0.1 Cucumaria spp.

0.5 1.0 0.1 Patiria miniata 0.3 0.5

<0.1 Strongylocentrotus franciscanus 0.3 0.5

<0.1 Romaleonjordani 0.3 0.5

<0.1 Brachyuran 0.3 0.5

<0.1 Invertebrate Cover Balanus/Tetraclita spp.

0.3 0.2 0.1 0.2 0.3 0.4

<0.1 0.1 0.2 bryozoa (encrusting)

<0.1

<.01

<0.1

_Spirorbidaee

<0.1

<.01

<0.1 ESLO2015-05G-G-3

Appendix G - Subtidal Invertebrates Table G3. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, North Diablo Cove Station NDC 3 -3m (9-10).

S urvey 164 165 16616 Std.

Std.

,,Std.

Std.

AnnUal Taxon '

.,Mean, Dev.

Mean Dev.

Mean...

Dev.

Mean, Dev.

Mean Invertebrate Counts Strongylocentrotus purpuratus Pelecypoda boring Phragmatopoma califomnica Ophiothrix spiculata Ophiactis simplex Sipunoula Cirratulidaelrerebellidae Lottia ochracea Serpulidae Anthopleura elegantissima Fissurella volcano St rongylocent rot us franciscanus Cucumaria spp.

Epiactis prolifera Eudistylla polymorpha Anthozoa Sabellidae Polychaeta Lissothuria nutriens Acmaea mitra Diodora spp.

Lottiidae lschnochitonidae Placiphorella velata Elysia hedgpethi Aeolidiella oliviae Pteropurpura festiva Invertebrate Cover Balanus/Tetraclita spp.

Spirorbidae tunicates, compound/social Porifera (encrusting)

Salmacina tribranchiata 41.0 26.5 7.3 12.0 8.3 2.5 1.8 0.8 0.8 1.0 0.8 0.8 0.3 0.3 0.3 0.3 0.3 0.3 28.5 25.9 8.4 10.3 4.8 1.3 1.0 1.0 1.0 0.8 1.0 1.0 0.5 0.5 0.5 0.5 0.5 0.5 34.8 21.5 40.8 13.4 16.3 28.6 5.0 3.6 6.8 8.4 1.8 1.0 3.8 2.1 0.5 0.6 1.0 0.8 0.5 1.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.8 1.0 0.3 0.5 0.3 0.5 35.3 42.5 8.5 11.8 10.0 4.8 0.8 0.8 0.5 0.3 1.0 1.8 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.3 0.3 22.4 12.7 8.4 10.3 8.0 2.8 1.0 1.0 1.0 0.5 0.8 1.7 0.5 1.0 0.5 0.6 0.5 0.6 0.6 0.5 0.5 31.5 24.5 19.5 14.4 5.0 6.4 3.0 6.0 6.5 5.2 3.0 1.4 0.5 0.6 0.5 0.6 0.5 1.0 0.8 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.8 1.5 0.5 0.6 0.3 0.5

<0.1

<.01 35.6 32.3 9.3 7.9 7.9 3.0 0.9 0.9 0.8 0.6 0.6 0.5 0.5 0.4 0.3 0.3 0.3 0.3 0.3 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 0.1 0.2

<0.1

<.01

<0.1

, <.01

<0.1

<.01 ESLO2015-05 G-4

Appendix G - Subtidal Invertebrates Table G4. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in 2; percent cover) standard deviations and annual means, North Diablo Cove Station NDC 4 -4rn (9-15).

Survey Date 5...

-!Feb-14 9-May-14 1"6-Jul-14 11-Nov-14 i,

Std.,

Std.

,Std.

Std.

Annual Taxon Mean*'

Dev.

Mean 0ev. "

Mean Dev...

Mean....

0ev.'

'Mean Invertebrate Counts Phragmatopoma califomica Strongylocentrotus purpuratus Pelecypoda boring Ophiectis simplex Ophiothrix spiculata Alia spp.

Serpulidae Acmaea mitra Anthopleura ele gantissima Sipuncula Lottia ochracea Amphissa spp.

Epiactis prolifera Fissurella volcano Tonicella lineata Pa gurus spp.

Pugettia spp.

Lirobittium spp.

Serpulorbis squamigerus Ischnochitonidae Cucumarie spp.

Chaetopteridae Pista spp.

Lissothuria nutriens Anthozoa snail Doriopsilla albopunctata Dendropomna spp.

Eulithidium spp.

Diodora spp.

Crepidula app.

Homolo. luridum/Lirularia succincta Polychaeta Ocinebrina spp.

Phidiana hiltoni Scyra acutifrons Anthopleura artemisia Pododesmus cepio Chloro stoma brunnea Conus californicus Hermissenda crassicomis Sabellidae Diopatra ornate 98.8 65.2 11.5 13.5 14.0 21.4 5.5 6.7 4.0 1.8 0.3 0.5 0.8 0.5 2.3 1.7 1.3 1.9 0.3 0.5 1.3 1.5 0.5 0.6 0.3 0.5 0.3 0.5 0.5 0.6 0.5 1.0 0.3

  • 0.5 0.3 0.5 0.3 0.5 1.0 1.4 1.0 2.0 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 44.8 13.0 6.0 5.5 3.3 1.5 2.0 1.0 0.8 1.8 2.0 0.8 0.5

.0.5 0.8 0.3 0.8 0.5 0.5 0.3 1.0 0.3 0.3 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 58.0 18.7 8.0 6.5 1.9 1.9 0.8 0.8 1.0 1.0 2.2 1.0 0.6 0.6 1.5 0.5 1.0 1.0 0.6 0.5 2.0 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 22.3 10.0 3.0 4.0 2.3 1.8 1.8 1.3 2.3 0.5 1.8 1.0 1.8 1.0 0.5 0.3 0.5 1.3 0.8 0.3 0.3 1.0 0.3 0.3 0.8 0.5 14.7 11.5 1.0 6.0 1.4 1.7 1.0 1.3 1.3 3.9 0.6 1.7 1.0 0.6 0.8 1.7 1.4 0.6 0.5 1.0 2.5 1.5 0.5 0.5 2.0 0.5 0.5 1.0 0.6 0.5 52.3 11.3 11.8 5.3 2.5 2.5 1.8 0.5 1.8 0.8 0.8 0.8 1.0 0.3 0.3 0.3 0.5 0.3 0.3 0.5 0.3 0.8 0.3 0.5 0.5 0.3 0.3 54.0 11.0 21.6 9.8 1.3 3.1 1.0 0.6 2.2 1.0 1.0 1.0 2.0 0.5 0.5 0.5 0.6 0.5 0.5

.1.0 0.5 1.0 0.5 0.6 0.6 0.5 0.5 54.5 11.4 8.1 4.8 3.4 1.6 1.6 1.4 1.3 1.3 1.1 0.8 0.7 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1

<0.1 (table continued)

  • ESLO2015-05 G-5

Appendix G - Subtidal Invertebrates Table G4 (continued). Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, North Diablo Cove Station NDC 4 -4m (9-15).

Survey 1::i64
165, 166 67

'*Survey Date 5-Feb:14 ':

':*9-May-'14 ";'

1'6-Jul-1'4 **,..

11-Nov-14

1*'

]

,, Std.

Std..,,

Std.

  • Std.

,Annual Taxon" Mean:

Dev.

Meanr**

Dev."

Mean

Dev*..

Mea'n" Dev.

Mean Invertebrate Counts (continued)

Pycnogonida 0.3 0.5

<0.1 Patiria miniata 0.3 0.5

<0.1 Placiphorella velata 0.3 0.5

<0.1 Ophiuroidea 0.3 0.5

<0.1 Eudistyfia polymorpha 0.3 0.5

<0.1 Mimulus foliatus 0.3 0.5

<0.1 Majidae 0.3 0.5

<0.1 Pisaster/Henricia spp. (juv.)

0.3 0.5

<0.1 Strongylocentrotus spp.

0.3 0.5

<0.1 Cancridae 0.3 0.5

<0.1 Lepidozona spp.

0.3 0.5

<0.1 Kelletia kelletii 0.3 0.5

<0.1 Navanax inermis 0.3 0.5

<0.1 Invertebrate Cover Balanus/Tetraclita spp.

0.6 0.7 0.1 0.2 0.5 0.7 0.3 Porifera (encrusting) 0.2 0.3

<0.1

<.01

<0.1

<0.1

<0.1 tunicates, compound/social

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1

<0.1 bryozoa (encrusting)

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1

<0.1 Spirorbidae

-c 0.1

<.01

<0.1

<0.1

<.01

<0.1 8*'*ESLO2015-05G6G-6

Appendix G - Subtidal Invertebrates Table G5. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in 2; percent cover) standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).

Survey 164 165 166 1.

167 I

Survey Date 6-Fe-14 12-May-14 7-Aug-14 4-Nov-14 td o

Std.

Std.

Std. I Annual Taxon Mean...

Dev.

,,Mean Dev.

Mean i':Dev.

,'Mean

,Dev. I.

Mean Invertebrate Counts Ophiothrix spiculata Phragmatopoma califomica Chaetopteridae Alia spp.

Pista spp.

Sipuncula Pelecypoda boring Pa gurus spp.

Serpulidae Amphissa spp.

Acmaea mitra Fissurella volcano Chlorostoma brunnea Ophiuroidea Ophiactis simplex Ischnochitonidae Serpulorbis squamigerus Lottia ochracea Pugettia spp.

Diopatra omnata Anthozoa Balanophyllia elegans Anthopleura elegantissima Patiria miniata Strongylocentrotus purpuratus Eulithidiurn spp.

Anthopleura artemisia Tonicella lineata Lirobittiumi spp.

Cucumania spp.

Scyra acutifrons 1-omolo. lunidum/Lirulania succincta Lottiidae Crepidula spp.

Doriopsilla albopunctata Mimulus foliatus Majidae Modiolus spp.

Cirratulidae/Terebellidae Romaleon jordani Epiactis prolifera Nemertea Pododesmus cecic 23.8 11.1 15.0 23.4 0.3 0.5 1.3 1.0 3.5 2.4 2.5 1.7 4.5 7.0 0.5 1.0 1.3 1.3 0.5 1.0 1.3 1.0 0.3 0.5 0.8 1.0 0.8 1.0 0.5 1.0 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.5 0.6 5.5 6.3 11.0 2.3 3.0 1.5 1.8 0.5 3.0 2.0 1.3 1.3 0.3 1.5 1.3 1.5 0.5 0.5 0.3 0.3 0.3 0.3 0.5 0.3 0.3 0.3 0.8 0.3 0.3 0.3 0.3 4.2 1.5 10.0 1.5 4.8 0.6 1.5 0.6 1.6 1.4 1.3 0.5 0.5 0.6 1.9 1.3 0.6 0.6 0.5 0.5 0.5 0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 6.0 4.1 10.3 4.0 4.3 1.3 6.8 7.5 1.3 1.0 3.0 2.2 1.5 1.3 5.3 4.2 2.0 1.8 1.5 0.6 1.8 1.7 1.0 0.8 3.5 3.7 1.0 1.2 0.5 1.0 0.5 0.6 0.3 0.5 0.5 1.0 0.5 0.6 1.0 2.0 0.3 0.5 0.3 0.5 0.8 1.0 0.3 0.5 0.5 0.6 0.3 0.5 0.8 1.0 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.5 1.0 0.3 0.5 0.3 0.5 2.5 2.3 2.0 3.5 4.5 3.5 0.3 2.0 1.3 0.8 1.3 0.5 0.3 0.5 0.8 0.3 0.8 0.3 0.3 0.5 0.5 0.3 0.3 1.0 0.5 0.3 0.3 0.3 0.3 0.3 3.0 1.5 0.8 3.1 3.0 1.9 0.5 1.4 1.0 1.0 1.0 0.6 0.5 0.6 1.0 0.5 1.0 0.5 0.5 0.6 0.6 0.5 0.5 2.0 0.6 0.5 0.5 0.5 0.5 0.5 9.4 8.4 4.4 3.4 3.1 2.6 2.0 1.9 1.7 1.4 1.2 1.0 1.0 0.8 0.6 0.6 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

<0.1

<0.1

<0.1 (table continued)

I

' ESLO2015-05 G-7

Appendix G - Subtidal Invertebrates Table G5 (continued). Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in 2; percent cover) standard deviations and annual means, South Diablo Cove Station SDC 2 -3m (12-10).

i Survey

, 164 -,

1" 65 *

` 1166 167 St.Std.

Std.

Std.*

Annual T*axon i -*

Meani

..Dev.

Mean Dev:.

"Mean Dev.

Mean Dev.,

, Mean Invertebrate Counts (continued)

Onchidella borealis 0.3 0.5

<0.1 Sabellidae 0.3 0.5

<0.1 Pycnogonida 0.3 0.5

<0.1 Romaleon antennanius 0.3 0.5

<0.1 Pycnopodia helianthoides 0.3 0.5

<0.1 Phidiana hiltoni 0.3 0.5

<0.1 Eudistylia polymorpha 0.3 0.5

<0.1 Paracya thus steamnsfii 0.3 0.5

<0.1 Lissothuria nutriens 0.3 0.5

<0.1 Lepidozona spp.

0.3 0.5

<0.1 Eupentacta quinquesemita 0.3 0.5

<0.1 Navanax inermis 0.3 0.5

<0.1 Invertebrate Cover Porifera (encrusting) 0.3 0.4

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1 bryozoa (encrusting)

<0.1 0.1

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1 Balanus/Tetraclita spp.

<0.1 0.1

<0.1 Spirorbidae

<0.1

<.01

<0.1

<0.1

<0.1

<.01

<0.1

  • tunicates, compound/social

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1 Hydroidolina

<0.1

<.01

<0.1

  • Acanthancora cyanocrypta

<0.1

<.01

<0.1 Salmacina tribranchiata

<0.1

<.01

<0.1 ESLO2015-05 G-8

Appendix G - Subtidal Invertebrates Table G6. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in12; percent cover) standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).

urvey 16 165 166 167 S Survey, Date' 24-Feb-14 2-*Jun-14 17li-Jul-4' 5

-Nov-14 I..

Std.,

Std.,

°Std.

Std.

  • Annual Taxon

{

Mean.

Dev.

Mean... 0ev.,

Mean, Dev.:

Mean 0ev. 4 Mean Invertebrate Counts Balanophyllie elegans Phragmatopoma californica Chaetopteridae Serpulidae Pista spp.

Amphissa spp.

Ant hopleura elegentissima Alia spp.

Diopatra ornate Pa gurus spp.

Serpulorbis squarnigerus Ophiothrix spiculeta Sabellidae Sipuncula Strongylocentrotus purpuratus Mitra idae Pelecypoda boring Dendropoma spp.

Paracyathus steamsii Pugettia spp.

Anthopleura arternisia Crepidula spp.

Tethya califomiana Pseudomelatoma torosa Scyra acutifrons Acmaea mitra Patinia minieta Doriopsilla albopunct ate Ophiuroidea Ophiactis simplex Homolo. luridum/Lirularia succincta Cucumaria spp.

Eulithidium spp.

Anthozoa Loxorhynchus spp.

Ocinebrna spp.

Mimulus foliatus Majidae Lottia ochracea Conus celifornicus Calliostoma spp.

Eupentacta quinquesemita Epiactis prolifera 24.3 14.2 17.3 7.6 I 20.8 5.7 I 23.5 9.3 0.5 3.5 2.0 2.3 1.8 2.8 1.8 1.0 0.5 0.5 1.3 0.5 1.3 1.0 0.5 1.8 0.5 0.3 0.3 0.5 1.0 0.5 0.5 0.5 0.5 0.3 0.5 0.5 0.5 0.3 0.3 0.3 1.0 2.4 1.2 1.5 1.0 1.5 1.5 1.4 0.6 0.6 1.3 0.6 1.5 0.8 0.6 3.5 1.0 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.5 1.0 1.0 0.6 0.5 0.5 0.5 0.6 0.5 3.0 2.6 5.3 4.0 2.0 0.8 2.8 1.0 5.0 2.2 2.0 0.8 1.5 1.7 1.8 1.0 0.8 1.0 0.8 1.0 1.8 1.5 2.8 3.8 1.0 0.8 0.8 1.0 1.0 0.8 0.5 0.6 1.3 2.5 0.5' 1.0 0.5, 0.6 0.8 0.5 0.3 0.5 0.5 1.0 0.5 0.6 0.3 0.5 0.3 0.5 0.5 1.0 0.5 0.6 0.5 1.0 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 8.0 6.5 2.5 2.1 5.3 1.7 2.8 2.2 1.8 1.5 1.5 0.6 2.8 2.2 0.8 1.5 2.3 2.1 1.5 0.6 0.8 1.0 1.5 1.3 1.0 0.8 0.8 0.5 0.8 1.0 0.8 1.5 0.5 0.6 0.5 1.0 0.3 0.5 0.3 0.5 0.5 0.6 0.8 1.0 0.5

'0.6 0.5 0.6 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 8.0 3.2 5.0 4.6 1.3 1.0 2.5 1.3 1.0 1.4 1.8 1.5 2.0 0.8 1.3 1.3 1.5 1.9 2.3 1.9 2.0 0.8 0.8 1.0 1.8 1.0 1.0 0.8 0.8 1.0 1.8 1.7 1.0 0.8 0.8 1.0 1.0 0.8 0.8 1.0 0.5 0.6 0.8 1.0 0.5 0.6 0.3 0.5 1.0 2.0 0.5 1.0 1.0 2.0 0.3 0.5 0.5 0.6 0.3 0.5 0.5 1.0 21.4 4.9 4.1 2.6 2.6 2.4 2.0 1.6 1.4 1.4 1.3 1.3 1.2 1.2 1.0 0.9 0.9 0.8 0.7 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1

<0.1 0.5 0.3 (table continued)

I* 'ESLO2015-05 G-9

Appendix G - Subtidal Invertebrates Table G6. (continued) Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in 2; percent cover) standard deviations and annual means, South Diablo Cove Station SDC 3 -4m (10-15).

Survey 164 15 166 167 SSurvey Date 24-Feb-14 2-Jun-14 17-JuM-4 5-Nov-14 Std.

'Std.

St~d:

Std>"

Aninual

.Taxon Mean 0 ev,.

Mean Dev.

Mean 0 ev,.

'Mean Dev..

Mean invertebrate Counts (continued)

Nemertea '0.3 0.5

<0.1 Fissurella volcano 0.3 0.5

<0.1 Pomaulax gibberosa 0.3 0.5

<0.1 Promadtynia pulligo 0.3 0.5

<0.1 Pycnogonida 0.3 0.5

<0.1 Trio pha catalinaee 0.3 0.5

<0.1 Ophioplocus esmarki 0.3 0.5

<0.1 Lophopanopeus spp.

0.3 0.5

<0.1 Lissothuria nutriens 0.3 0.5

<0.1 Lepidozona spp.

0.3 0.5

<0.1 Haliotis spp.

0.3 0.5

<0.1 Pteropurp ura festiva 0.3 0.5

<0.1 Invertebrate Cover Balanus/T~etraclita spp.

0.3 0.5 5.9 7.5 0.4 0.8 0.3 0.5 1.7 Acanthancora cyanocrypta 0.2 0.3 0.1 0.3 0.4 0.5 1.2 0.2 0.5 Porifera (encrusting)

<0.1

<0.1 0.2 0.4 0.4 0.5 0.1 bryozoa (encrusting) 0.2 0.3

<0.1

<0.1 0.1

<0.1

<0.1 tunicates, comnpound/social

<0.1

<0.1

<0.1

<0.1

<0.1 Spirorbidae

<0.1

<.01

<0.1

<.01

<0.1

<.01

<0.1 0*** ESLO201 5-05G-0 G-10

Appendix G - Subtidal Invertebrates Table G7. Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, South Control Station S C 1 -3 m (19-10).

Survey 1

64

.. 165

  • .. 166
  • 167..

.. SurVey Date

  • 4-Apr-14...

'.18-Jun-14 12,Aug-14 8-Dec-14

,Taxon..

,Mean.

.. Dev... Mean...

..Dev.

Mean Dev., Mean

-, Dev...

Mean Invertebrate Counts Phragmatopoma califomnica Dendropoma spp.

Pa gurus spp.

Homolo. luridum/Lirularia succincta Chiorostoma brunnea Balanophyllia elegans Pugettia spp.

Alia spp.

Lottia instabilis Lottia insessa Tonicella lineata Amphissa spp.

Mitra idae Crepidula spp.

Pista spp.

Calliostoma ligatume Leptasterias spp.

Patiria miniata Mimulus foliatus Pisaster/Henricia spp. (juv.)

Serpulidae Acmaea mitra QOinebnina spp.

Scyra acutifrons Serpulorbis squamigerus Strongylocentrotus purpuratus Lissothunia nutriens Anthopleura ele gantissima Epiactis prolifera Mopalia spp.

Lottia ochracea Diopatra ornata Lirobittium s pp.

Pododesmus cepic Lottiidae Aptyxis luteopictus Lophopanopeus spp.

Lepidozona spp.

Chaetopteridae Anthozoa Promartynia pulligo Romaleon antennarius Loxorhvnchus spp.

131.8 8.8 9.0 4.5 7.0 2.0 3.0 1.3 1.8 0.3 0.8 1.3 0.8 1.0 0.5 0.3

.0.8 0.8 0.5 0.5 0.8 1.3 0.3 0.3 0.5 0.3 0.5 0.5 0.3 0.5 0.5 262.2 17.5 10.4 1.3 4.2 2.8 2.7 1.9 1.5 0.5 0.5 1.5 1.5 0.8 0.6 0.5 0.5 0.5 0.6 0.6 1.0 0.5 0.5 0.5 0.6 0.5 0.6 0.6 0.5 0.6 0.6 169.5 321.8 1.0 2.0 12.0 4.4 8.8 8.3 3.0 1.8 1.5 2.4 1.5 0.6 1.8 1.7 2.3 2.6 1.3 0.5 1.0 0.8 0.3 0.5 0.5 1.0 2.0 1.8 0.8 0.5 0.8 1.0 1.0 1.4 1.3 1.3 0.8 0.5 0.5 1.0 0.8 1.0 0.5 0.6 0.8 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 0.5 0.6 0.3 0.5 0.8 0.5 0.3 0.5 203.5 33.5 2.8 4.3 0.8 2.5 0.5 0.8 3.3 1.3 0.3 0.3 0.5 0.5 0.5 0.3 0.3 0.8 0.3 0.5 0.5 0.3 0.3 0.8 397.7 51.7 3.6 1.7 0.5 3.1 0.6 0.5 3.8 1.3 0.5 0.5 1.0 1.0 0.6 0.5 0.5 1.0 0.5 0.6 0.6 0.5 0.5 1.0 142.5 10.8 4.8 9.5 2.5 1.5 2.3 2.5 1.0 1.8 1.3 1.8 0.3 0.5 0.3 0.3 0.3 0.5 0.3 0.3 0.5 0.5 0.3 0.8 0.8 0.5 0.8 0.3 0.8 0.3 271.7 5.4 4.1 4.2 3.3 1.7 1.3 1.9 1.0 0.5 1.7 0.5 0.6 0.5 0.5 0.5 0.6 0.5 0.5 1.0 0.6 0.5 1.0 1.0 1.0 1.0 0.5 1.5 0.5 161.8 10.8 8.6 5.6 5.1 2.1 1.6 1.5 1.4 1.1 0.9 0.9 0.8 0.7 0.7 0.6 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 (table continued) 0*P*ESLO2015-05 G-11

Appendix G - Subtidal Invertebrates Table G7 (continued). Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 m; percent cover) standard deviations and annual means, South Control Station SC 1 -3m (19-10).

°, *:

Survey' 164" 165 i

166:

167 "Survey Date 4-Ap~r-14 18-Jun-14 12-Aug-14 '

8-Dec-14:':

"Std,.

Std....., o Std.

Std, Annual Taxono Mean' Dev.t
Mean, 0ev.

,Mean-,

Dev.

Mean Dev,_

Mean Invertebrate Counts (continued)

Doriopsilla albopunctata 0.5 1.0 0.1 Pseudomelatoma torosa 0.5 0.6 0.1 Ischnochitonidae 0.5 0.6 0.1 Placiphorella velata 0.5 0.6 0.1 Pelecypoda boring 0.3 0.5 0.3 0.5 0.1 Dicdora spp.

0.3 0.5

<0.1 Fissurella volcano 0.3 0.5

<0.1 Epitonium/Opafia spp.

0.3 0.5

<0.1 Cancer productus 0.3 0.5

<0.1 Ophiothrix spiculata 0.3 0.5

<0.1 Cryptolithcdes sitchensis 0.3 0.5

<0.1 Strongylocentrotus spp.

0.3 0.5

<0.1 Cancridae 0.3 0.5

<0.1 Sipuncula 0.3 0.5

<0.1 Pachycheles spp.

0.3 0.5

<0.1 Eupentacta quinquesemita 0.3 0.5

<0.1 Romaleonjordani 0.3 0.5

<0.1 Invertebrate Cover Balanus/Tetraclitaspp.

0.3 0.1 0.2 0.3 0.1 0.3 3.8 4.0 1.1 Porifera (encrusting) 0.3 0.5 0.1 0.3 1.3 0.9

<0.1

-0.4 bryozoa (encrusting) 0.1 0.3

<0.1 0.1 1.1 0.9

<0.1 0.3 Spirorbidae

<0.1

<0.1 0.1 0.3

<0.1

<0.1 tunicates, compound/social

<0.1

<0.1 0.1 0.3

<0.1

<.01

<0.1 Hydroidolina

<0.1

<.01

<0.1

<.01

<0.1 Salmacina tribranchiata

<0.1

<.01

<0.1 ESLO201 5-05G12 G-12

S:i-e

£ VO 0-9 *0O071S9.*

(penuiluoo elqel)

£'0 VO "1'0 9'0 90 LO L'0 6'O ff0 6O I.OI ff'O VL' 8"0 V.'1, 8;'1, I,'L 90O 9'0 90O 9'0 90O 9"0 9"0 90"1 9'0 9'0 0"1.

0'1.

9'0 6'1, 90*I 6'1.

6"1.

F'1.

0'1.

L'9

£'0 9'0

£'0 9'0

£'0

£'0 9'0

£0'.

£'0 9'0

£'0 8"1.

9'0 09'1.

9'0 S.'1.

90'0 8'0 0'1.

£9' 9'0 801 S'1.

0.t7

'99 90"1 90"1 9"0 9'0 90'1 9'0 90 9'0 9'0 9'0 9'0 0' 1.

0'1.

9'0 8'0 g'[,

9'1, 0£'1.

001.

689 091.9 9'0 9'0 50" 9"0

£'0 9"0 9'0 50' 5'0

£'1.

5'0 9'0 90' 9'0 9'0 9'1, 91,

£9"1.

9.99 599 01, 9'0 9'0 9'0 01, 9'0 O'I, 0'1, 6'1.

0'1.

9'0 9'0 90 9'0 0'1.

6"1.

80" 9'1.

1.'1.

61.Z 9.9 9'99 9'701.

9'0 5'0 5'0 9"0 5'0 9'0 9'0 8'0

£'1.

8'0 90' 50' 5'0 0'1, 0'1.

9'0 0"1 091 9'17 0'9 9'69 9'0

£'0 9'0 VO 0'1.

9'0 O'Z 01.,

0'1.

9'0 9'0

£0' 9'0

£'O 9'0

£'O 9'0 5:0 9"0 9'0 9"0

£0O V1.

0'1.

0"1.

9"0 0'1.

9'0

01.

9'0 9'0

£'0 9'0 9'0 9"0 0'1.

0'1.

9'0 9'L 9'0 9'0 900 9"0 9'0 9'1.

90'

  • 1, OZ
  • '1, 0'1.
  • 1, 0'1.

9"0 0'1, OZ 0'1.

5£'

9"7

'z 5'6

£*"*

9'91.

090 0'01.

£'61.

£'1.S 0'96 0"9L 0"701.

g'£6 iplleWue snOOld~ldO snpoidoejnl s!x/ldV sn~eind, nd snjoiqueoopf95uoi4z*

ejewo eJ~edo!a of&i~nd eJuA4IRWOJd eUwlss!uefiolo elneldoqLuV bflutfl~u ell!IOne-eep! e.i!tj ejelioundoqle ell!sdo!uoa esoieqq,5 Xe~lneWOd

'dds snjoi jueoopfXiuoi~s

'dde se~uolse~de7

  • dde e~IV G*epie~doleeqO

('An. 'dde eIoIJuOH/.J;SeS~d

'dds e,*opo!Q 2JOJ!io~d s!qoefd9

  • dde elnpldeio 82p!il1oq

'w*nlzefi ewolzsOqlle3 eleoU~l elle~tUOL Ol!uW eoew~ov 6u!ioq epodaGoald

  • dde 2001'lnOID

'dde ess!qdwuv

'dds @euewono elzelnOlds x~uqlioijdo

  • dds P.flebnd oep!Inld~eS
  • dds 9uLJq0uIOo
  • dde Snflif,5d eeuuniq ewolzsololqQ
  • dds euwodoJpue(]

sniefJwenbe siq~olndies eoiuiojqleO ewodolzewbfe~qd sue~ele 9q;l, qdouele*

s*,unoo eleiqe~iaAUI lenuuv

'PS

....Ps'.

s

" P,..

P]s 1ue-1O

-mHr-cl*

171unr-£o a

  • 17-eLA-91 eweoaAeAnS L

91 991,.

j" 1791.

ns

,f-

"(0E-0E) W9-E ;OS uomIWS OIUOJ*u; t11nos 'suborn Pnuue pu SUOi.i1A~p parnpums (JOAO0 iuooiod '.i

  • EO.id oouepunqe) suetui *OAunS (poq~pj Oi) S) sog.qoIoAut Fp~qns "89 oiqgL se*,eiqe~ieAUl lp~!Wlqns - 5 X!pueddv/

Appendix G - Subtidal Invertebrates Table G8 (continued). Subtidal invertebrates (SFQ Method) survey means (abundance per 0.25 in2; percent cover) standard deviations and annual means, South Control Station SC 2 -6mn (20-20).

Survey '

164 1"

65

. 166 T.. 1 67....

i:

suirvey Date 25-M~ar-14"
.. 03-Jun-14, j

23-JulM4

02-Jan-15

,,Std.I i.,,

tStd.

Std..

Std.'

Annual STiaxon..

Mean, Dev.-

Mean.

Dev.,,

Mean :.Dev/

Mean:

0e.

D

,. Mean, Invertebrate Counts (continued)

Paracyathus steamsii 0.3 0.5 0.3 0.5 0.3 0.5 0.2 Ophiactis simplex 0.8 1.5 0.2 FissurelIa volcano 0.5 1.0 0.1 Chlorostoma montereyi 0.3 0.5 0.3 0.5 0.1 Pseudomelatoma torosa 0.3 0.5 0.3 0.5 0.1 Rostanga pulchra 0.5 1.0 0.1 Mimulus foliatus 0.3 0.5 0.3 0.5 0.1 Majidae 0.5 0.6 0.1 Scyra acutifrons 0.5 0.6 0.1 Haliotis spp.

0.5 1.0 0.1 Calliostoma spp.

0.5 1.0 0.1 Eupentacta quinquesemita 0.5 1.0 0.1 Cadlina spp.

0.5 1.0 0.1 Calliostoma annul alum 0.3 0.5

<0.1 Pododesmus cepio 0.3 0.5

<0.1 Caotosoma arenaria 0.3 0.5

<0.1 Sabellidae 0.3 0.5

<0.1 Poiychaeta 0.3 0.5

<0.1 Romaleon antennarius 0.3 0.5

<0.1 Calliostoma canaliculatum 0.3 0.5

<0.1 Cryptochiton stelleri 0.3 0.5

<0.1 Placiphorella velata 0.3 0.5

<0.1 Eulithidium spp.

0.3 0.5

<0.1 Modiolus spp.

0.3 0.5

<0.1 Cirratulidae/Terebellidae 0.3 0.5

<0.1 Mytilus spp.

0.3 0.5

<0.1 Doris spp.

0.3 0.5

<0.1 Invertebrate Cover Balanus/Tetraclita spp.

2.0 2.2 1.0 1.2 0.1 0.3 2.8 5.1 1.5 bryozoa (encrusting) 1.1 1.3 0.8 0.5 1.1 1.2 1.8 0.8 1.2 Porifera (encrusting) 1.5 1.7 0.8 0.7 0.4 0.5 0.6 0.8 0.8 Acanthancora cyanocrypta 0.6 1.1 0.5 0.6 0.4 0.8 0.3 0.5 0.5 bryozoa (erect)

<0.1

<.01

<0.1

<.01 0.2 0.1 0.6 0.2 0.2 tunicates, compound/social 0.2 0.3 0.5 0.5 0.2 Hydroidolina

<0.1

<.01

<0.1 Aglaophenia spp.

<0.1

<.01

<0.1 Abiet./Sertularella/Sertularia spp.

<0.1

<.01

<0:1 bryozoa (foliose)

<0.1

<.01

<0.1 Salmacina tribranchi ata

<0.1

<.01

<0.1

'E'SLO2015-05 G-14

Diablo Canyon Power Plant Appendix H Subtidal Fishes

I.-H 90-91.0;*O7S3._*hX (penufludo elqej)

I.'0>

I,'0>

I,'0>

1:'0>

I,'0>

I,'0>

I.'0>

I.'0>

L'O 6'0 6'0 LI.'

9"0>

9"0>

1'0>

1'0>

6"0>

6"0 10"1

'1:0

'1.0 I.'a 6"0 I. I0

£'0

  • '0

£'0

  • '0

£'0

  • '0
  • '0 v0>

£'0

  • '0
  • '0 1'0>
  • '0 v0>
  • '0 1,'0>

9'0

£'0

'0 I,'0>

9'0 9"0 6'0 6'0

'¢'0 V0

  • '0 6'0

£'0 6'0 6'*

64*

'£'0

  • '0 tVI4 9'0

'0 I,'0>

  • '0 1,'0>

'*'0

£'0

  • '0 1:0>
  • '0 I,'0>
  • '0 1'0>

9'0

£'0

£'0 Z'0 9'0

£'0

£'0

  • '0 04*

L'0

'0 I,'0>

1.'.

6'0 tV0

£'0 04I 9'0 47'0 1t"0 9'0 470 9'0 L'0 6"0 L'0

[0 4'4 i7'i7 0'7

[0 6'0

  • '0 I,'0>

9'£ 6'47

/*0 1'0>

6'0 470 6'0 9"0

  • '0 1.'0>

£L

£"7 47'0

£'0

£0

£'0

[0 9"0 i4'0 9'0 tV0 470

['0

£'0 L'0 8'0 4'0 470 9"0 4'0 1, 0>

£'0 9'0 6'0

£'0 9'0 470

['0 6'0 9'0 9'0

  • ' 1 6"0

'04

'0 1.0>

£'0 a'0

£'0

  • '0 9'0 6'0

£'0

  • '0

'v0

  • '0

't'0

£0O

[1.

£'0 9'0 9'0 1,'1, 6"0 L'.

£'.

9'0 8'0 9'1.

91.

1.6 9'6

  • '0 1.0>

9'0

£'0 91.,

0'1.

9'47 91.

('An!) Snl~o/a sn!qo/AxO ieqolnd snqd~fssoo!*ues

('AnD eoiw~ol~eO suln f~xo s~oeu!* seldouoqpo

  • dds snupp~v SnlZuGJJ sn/)s/AfqoeJ8

!slC qOu sdo~qofiouiq*j

&njlBo*UOp~le o~do

('AnQ Sfnp!A2l1 "s/ou~uaS selseqeS snuWWJBuefoep Sow~ueJBeXOH (AoA{)

sn p!Aelg "s/*oueJJs se,!ssqes

('AnD eCORA Snlf.qo~ooeq*

ssjoxoj snlpqoooeq*'

(1Ao/)

snlieuiso 'S/osi~qo solsqeqa SnGoelO!A s, qjqoip~qo3

('AnD sselwUosf/lqo selzseqes

('An.D !uos~jlfOC) ooloqUJ SUJI!AOJ)Se solseqos Joafila*iseJ sajssqes JooeA Snl!1pOooeL/

!uostoef eo~oioqw3 snlzejoujew sifqlqo~ueedJ~oo

'dds elsuoqq!Q

('AnD s!u~ds~oned sejseqe*

eoiwop!leO s*hln[,xo s2lOwos/dqo sojseqos

('AND !leie~lel eoo/o'quw3

('AnD snuqs~w sojseqos S~l9Je)Cl eoo~oiquw9

(/AoA) snuijs~fu sejseqes snpo!d snqqelAxO

('An.D UO>W uoyefoojO/qUw

!UOslsef soolo~qw3

('AND Snl)2uoJJ Snl!ls*qoSJe

('AnD Snp!Aell snqoufOpolnv sqle*olel eoo!o~qwj9 SnJZuo~J snqls!,qss*

SUJI!AOJZ2 SO)SRqGs

('AND Snlp!AS/J "S/' OU2JJGS Se*zS~qe$

(A0A) Snlp!AC/J "/'ournes sejseqos (Ro eA) np snlzsqooe5~

eouwojqleO siln f~xo

('AnD snu!is~w ssezseqe5 Ja~eMp!INj 6'0

£'0

  • ueOlA "AeO uee8AI J

,A

e*..

AGG3 ueeii Ae "Ue9*

J u~ea* '...

j uoxet lenuu P*S'

~

{

P £

'Pi.s :

P*,S.

,, :#poaQ.*g

.:~

479 l*Bv0

.iL,-n9

. t-d -

ae]/e n pu~l SuolO.Ie.A~p pa~purns '(;oosumi! in

  • x iz x Og.id oouepunqie) suetrni
  • OA.IftS soqst.., jpt;qns "111 oIqej.

seIJs!- le~pqn$~ - H xlpueddV

Appendix H - Subtidal Fishes Table Hi (continued). Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Field's Cove Stations (FC FO-1 (1), FC FO-2 (2), FC FO-3 (3)).

S..."

Survey

... 162'

1.

63.

" '164 1 65 :" ' '

SuvyDt 2-Apr-14 5,Ju1-14 30-Aug-14'i 31-Dec-14 i

Std."

Std '.

Std.

" Std,.

Anniual

Taxon, Mean Dev. ',Mean:

, Dev...

Mean,,"Dev.

Mean

... Dev.

Mean Benthic (continued)

Sebastes melanops

<0.1 0.2

<0.1 Girella nigricans

<0.1 0.2

<0.1 Sebastes atrovirens (yoy)

<0.1 0.2

<0.1 ESLO201 5-05H-H-2

9O-9-og~s

  • 75 (penufiuoo olqel)

L:'0

£'0 t,0 9'0 9'0 9"0 9'0 9'0

'0*

0'

  • 0"£ 91't L'9 9.9 0"6

'0>

VO>

LO>

LO>

1'*0 1'O0 VOL 9"0 9'0 VI, 8'0 1*'.

9'0 V'0

£;0 97; 07

£:0

£:0

£7*

8"i.

£;0

£'0 8'0 L'O

£'£ L',

a'.

9'9

£1.

t'9

['9 9'9 9'0

£;0 9'0

£'0

  • '0 I,'>

v70

  • '0
  • '0 L'O>

8'0

£:0 9"0

£;0 9"0

£'0 9'I, 8"0 9'0 6'0

,9*',

8'0

£:0

£'0

  • '0 1,'0>

07*

0£*

  • "1i 9'9
  • '£ 8'8 I,£ I'*

9'0

£'0

  • '0 L'0>
  • '0 I,'>

£'0

  • '0 v0
  • '0 V70

£'0

  • '0 I,'>
  • '0 I,'>

9'7 91, 80O 9"0

£7 9£*

99S

£7 9'0

£0

£:0

  • 0 v*0

£0 L'0 90 80

[0 1V0

£0

  • '0 IO>

9'1-L'l, 9'1.

£1'i 8"-

0'£ 9'0 9'0

£'.

1-I.

8£*

V'£ 0£f 8'17 1'0

£'0

£7 0'9 69g VL'

  • '0 1'0>

IVO

£;0

  • 'I, 9'0

£'0

£'0

£'0

£;0

  • '0 I,'0>

97*

0'-

  • '0 1'0>
  • '0 I,'0>

7'4 8"0 LI,

'LI 9'0 9'0 170 9'6 6'I, 9' I I 9'0

£'0 9'0

£'0 tV0 9'0

'. 0>

V'0

£:0 V'0

£'0 L'0.

9.9

£'I,

', 0>

£'0 9:0

£'0 8' I, V¢0 7' I,

('An I) i.slOt!U sdoi.qobouwq~'

sue.iu5! ellein!9 (1Ao/)

Sn p!An] "Sf'oue~L's seazs'qos s!le~e~zel noopioqwu9

('AnD s!/eie je/eoopzoqw3 sisue~ulol~leo eunle!9PelAV

  • dds e/suoqq!9

('AnD eoiwojqlnO s!lnI*xo Sn!2uOJJ Snl!lsIIqonJ8

('AND sn p!Ant "s/'oueJjes selsnqes sneleuos*{Io selzseqa5

('An.Q snln~qlelo xS~qelenJed

('AnD 9O~eA Snlpqo~ooeq*

('AnD I)UOsl~efeeo~op/,qWu eoonA Snlp~jOooeJ*I

('AnD snuijs~fu sojsnqe9

!'sloqo~u sdo/.qofiouiq*'

!UOs)lo9[ oop,!oqw3 (AoA) snups~uw selsnqe9 snpo~d sniiqel/Axo snpuno!qni sdod/[sdAfH

(/Ao1)

Snp!Aely "5loue~ies selsnqos SUOJ!AOJJS sejseqes

('AnDl Sn p!ASII "5/ousles se~sqeqa (AoA) snleuweo '$/'uosfkqo sejseqes s.Isue.Iu~o]!leo nunlnfeipA sisuelo/,u/.eo s!sdcu~uoqjv S/,le~e~l eoo~oiqwu9

('AnQ snleuay sn!is!/[qonig elzn'oseJ!woas s!ileul

!uos)loe[feoopo!qw3 sueopfJu ellej!9 sopiounJ~es sejseqe9'

('AnD snuls/[u sejseqe8

('AnD 90 oJu~o 9l0 silnf, xo eooeA SnlfiL/OooR4*

snlieuei] snfIs!bfqoneg (1Ao1) snuil s/[w sejseqe9 ewojunol~

sqlnf/[xo iaa~e~p!I/J Uee*j "A~ej Uualj A

aai,:* ueelNj

  • Ae u^

e n

A e~l ^Q:

u eeAij,}

uoxej jenuuv "P18 9

PlS P19 4-,

P£s 14.-eGa-0L

'Il-flV-OL 14-I, -'t,-n:....,

-JidV-LL ew

'9L-£1 9

AmaAIn*(L

-iC)N()

oJDN'()-o x)sui eAO oqnsj q:o "s~u wnuu, pu1£ SUlOi.:pAOp p.npUelS '(,ooSu3ii tUn X

x 7 x 05 ted eoumpunqi3) suanetu XeA.InlS setqsi [*npuqnS "znH olg seqs!-I leP~qns - H xipueddv

Appendix H - Subtidal Fishes Table HI2 (continued). Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, North Diablo Cove Stations (NDC FO-1 (5), NDC FO-2 (6), NDC FO-3 (7)).

Survey

.162 163 164

'165

' "Survey Date 11'-Apr-14!

<i 4-Jul-14 30-Auig-14

""30-Dec-14 Std.

Std.

Std.

Std.:

Annual Taxon

.i,

Meani Dev.
,Mean '

Dev..

..,Mean Dev..

Mean Devy.

Mean Benthic (continued)

Sebastes se'rranoides 0.2 0.3 0.7 1.6

<0.1 0.2 0.2 Scorpaenichthys marmoratus 0.2 0.3 0.2 0.4 0.3 0.4 0.3 0.3 0.2 Sebastes atrovirens 0.5 0.8

<0.1 0.2 0.2 0.4 0.2 Ophiodon elon gatus 0.2 0.4 0.4 0.4 0.1 Artedius spp.

0.2 0.3 0.2 0.4 0.2 0.4

<0.1 0.2 0.1 Paralabrax clathratus 0.4 0.6 0.2 0.4 0.1 Semicossyphus pulcher 0.3 0.3 0.3 0.4 0.1 Sebastes rastrelliger 0.2 0.3 0.2 0.4

<0.1 0.2 0.1 Sebastes rastrelliger~juv.)

<0.1 0.2 0.2 0.4 0.2 0.4 0.1 Urobatis halleri

<0.1 0.2 0.2 0.3 0.2 0.3 0.1 Chromis punctipinnis (juv.)

0.3 0.6

<0.1 Triakissemifasciata

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1 Sebastes melanops (yoy) 0.2 0.4

<0.1 0.2

<0.1 Sebastes chrysom./S, camatus (yoy) 0.2 0.4

<0.1 0.2

<0.1 Hypsypops rubicundus

<0.1 0.2 0.2 0.3

<0.1 Scorpaenichthys marmoratus (juv.)

0.2 0.4

<0.1 Brachyistius frenatus (juv.)

0.2 0.4

<0.1 Paralabrax nebulifer 0.2 0.4

<0.1 Hypsurus caryi~uv.)

<0.1 0.2

<0.1 Onrthonopias triacis

<0.1 0.2

<0.1 Pleuronichthys coenosus

<0.1 0.2

<0.1 Hexagramrnmos decagrammus (juv.)

<0.1 0.2

<0.1 Sebastes chrysornelasg(uv.)

<0.1 0.2

<0.1 Neoclinus stephensae

<0.1 0.2

<0.1 Sebastes atrovirens (yoy)

<0.1 0.2

<0.1 Oxylebius pictus (uv.)

<0.1 0.2

<0.1 Gymnothorax mordax

<0.1 0.2

<0.1 ESLO201 5-05H4 H-4

Appendix H - Subtidal Fishes Table 113. Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, South Diablo Cove Stations (SDC FO-1 (8), SDC FO-2 (9), SDC FO-3 (10)).

'iSuvey Date

  • 9-Apr-14' 5-Jul-14 31-Aug-14.

31-Dec-14 j

,Stdl. I

Std.

std.: " '

Std.:

Annual

.Taxon Mean

,Dev. j Mean*

Dev.

Mean Dev.

, Mean 0ev.

, Mean Midwater Atherinopsidae Brachyistius frenatus Sebastes serrano,/S. flavidus (juv.)

Oxyjulis califomica (juv.)

Brachyistius frenatus (juv.)

Oxyjulis califomica Sebastes serranoS./S flavidus (yoy)

Atherinopsis califomiensis Embiotooa jacksoni Rhacoohilus vacca Rhacoohilus vacca (juv.)

Sebastes atrovirens Girella nigricans Sebastes serranoides Sebastes chrysomS./S camatus (yoy)

Sebastes mystinus (juv.)

Paralabrax clathratus Sebastes paucispinis (juv.)

Paralabrax clathratus (juv.)

Medialuna californiensis Semicossyphus pulchar Benthic Oxyjulis califomica (juv.)

Rhacochi/us vacca Oxy/ebius plot us Aulorhynohus flavidus (juv.)

Brachyistius frenatus Rhino gobiops nioholsi Sebastes serranoides/S. f/a vidus Cit hariohthys spp.

Sebastes ohrysomelas Embiotooa jaoksoni Sebastes oaurinus (yoy)

Sebastes mystinus (juv.)

Oxyjulis oalifomioa Rhaoohi/us vaooa (juv.)

Sebastes rastrelliger Gibbonsia spp.

Sebastes ohryso./S. oarnat us (yoy)

Sebastes serranoS./S flavidus (juv.)

Sebastes atrovirens Sebastes rnystinus (yoy)

Ophiodon a/on gatus Sebastes serranoides 1.6 1.3 0.7 1.2 1.0 1.0 0.5 0.8 0.9 2.3 0.3 0.6

<0.1 0.2

<0.1 0.2 8.8 0.5 4.3 3.4 2.3 2.8 1.5 1.4 0.5 0.7 0.8 0.2

<0.1 7.6 0.4 0.8 0.9 0.9 5.8 1.9 0.8 1.8 2.8 1.7 0.5 2.3 0.5 0.3 1.8 0.3 1.0 0.3 1.1 19.3 0.8 10.4 2.5 3.3 3.8 1.6 3.0 0.6 1.2 1.2 0.3 0.2 8.2 0.5 1.8 1.1 1.6 3.1 2.5 1.6 2.3 4.7 1.6 0.6 2.9 0.5 0.4 1.8 0.8 1.6 0.4 2.2 67.3 3.8 3.0 0.5 0.4 2.2 1.9 3.1 0.7 0.3 0.3

<0.1 0.2

<0.1 0.3 3.2 8.1 1.0 3.0 0.5 3.7 1.2 1.2 1.3 0.5 0.3 0.4 0.8 1.2 0.2 1.4 0.2 0.4 69.2 6.3 3.5 0.6 0.5 1.2 4.5 5.1 0.8 0.4 0.4 0.2 0.3 0.2 0.8 2.1 16.8 1.7 2.4 0.8 2.9 0.8 1.2 1.4 1.0 0.6 0.8 0.7 1.0 0.4 1.2 0.4 0.6 6.8 10.7 1.9 3.4

<0.1 0.2 6.7 10.1 2.9 7.1 1.1 1.1 0.2 0.4 0.2 0.3 0.3 0.3 17.6 38.0 0.5 0.8 3.0 3.9 5.1 8.3 2.1 2.0 0.3 0.4 0.2 0.4 1.4 1.7 0.8 1.1 2.2 2.4 0.6 0.5 0.2 0.4 0.2 0.4 0.4 0.5 0.3 0.4 20.7 1.9 1.8 1.8 1.7 1.3 1.2 0.8 0.7 0.6 0.4 0.2 0.2 0.2 0.2 0.1

<0.1

<0.1

<0.1

<0.1

<0.1 4.4 3.1 2.4 2.2 1.8 1.8 1.7 1.5 1.4 1.4 1.0 0.9 0.8 0.7 0.6 0.5 0.5 0.5 0.5 0.4 0.4 0.3 3.8 3.0 0.3 1.1 0.3 0.3 2.3 1.8 1.6 0.3 0.6 0.5 0.3 1.8 0.4 0.2 7.6 2.2 0.4 1.1 0.6 0.6 2.6 2.3 3.9 0.6 0.6 0.3 0.4 3.2 0.5 0.4 (tablecoontinued) aW ES LO2O15-05 H-5

Appendix H - Subtidal Fishes Table Ht3 (continued). Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, South Diablo Cove Stations (SDC FO-i (8), SDC P0-2 (9), SDC FO-3 (10)).

S Survey Date 9-Apr-14.

o 5-Jul-14 31-Aug-14,:,31-Dec-*14 Std.

Std.

Std.

Std.-

Annual Taxon Mean Dev.;

Mean Dev.,

,Mean.,

Dev.

Mean' DevJ'

_,Mean.

Benthic (continued)

Embiotoca lateralis 0.5 0.6 0.6 0.8

<0.1 0.2 0.3 Rhinogobiops nicholsi (juv.)

0.3 0.4 0.8 1.6 0.3 Scorpaenichthys marmoratus 0.5 0.5

<0.1 0.2

<0.1 0.2 0.3 0.3 0.2 Pleuronichthys coenosus 0.3 0.4 0.2 0.3 0.3 0.3

<0.1 0.2 0.2 Artedius spp.

0.2 0.3 0.4 0.8

<0.1 0.2 0.2 Girella nigricans 0.6 1.4 0.1 Sebastes paucispinis (juv.)

0.6 0.7 0.1 Citharichthys stigmaeus 0.5 1.2 0.1 Orthonopias triacis 0.2 0.4 0.3 0.3 0.1 Pleuronichthys coenosus (yoy) 0.2 0.4 0.3 0.6 0.1 Rhacochilus toxotes

<0.1 0.2 0.2 0.3

<0.1 0.2

<0.1 Hexagrammos decagrammus 0.2 0.4 0.2 0.4

<0.1 Paralabrax clathratus 0.3 0.6

<0.1 Urobatis hailer!

0.2 0.4 0.2 0.3

<0.1 Cit harichthys spp. (juv) 0.3 0.6

<0.1 Paralabrax clathratus (iuv.)

0.3 0.6

<0.1 Brachyistius frenatus (juv.)

<0.1

,0.2 0.2 0.4

<0.1 Aulorhynchus flavidus 0.2 0.4

<0.1 Embiotoca lateralis (juv.)

<0.1 0.2

<0.1 0.2

<0.1 Cebidichthys violaceus 0.2 0.4

<0.1 Sebastes rast relliger (uv.)

<0.1 0.2

<0.1 0.2

<0.1 Sebastes chrysomelas (juv.)

0.2 0.3

<0.1 Embiotoca Jacksoni (juv.)

<0.1 0.2

<0.1 0.2

<0.1 Triakis semifasciata 0.2 0.3

<0.1 Neoclinus stephensae

<0.1 0.2

<0.1 0.2

<0.1 Sebastes miniatus (yoy) 0.2 0.4

<0.1 Pleuronichthys spp.

0.2 0.3

<0.1 Hypsurus caryi

<0.1 0.2

<0.1 Heterostichus rostratus

<0.1 0.2

<0.1 Scorpaenichthys marmnoratus (juv.)

-<0.1-0.2

<0.1 Platyrhinoidis triseriata

<0.1 0.2

<0.1 Myliobatis califomica

<0.1 0.2

<0.1 Oxylebius pictus (iuv.)

<0.1 0.2

<0.1 ESLO2015-05H-H-6

0 mr 00 0

ro o

"T" w

CD CD CD CD

~

~o Co Co Cb~

~

oo~0CDCDCDCbO0OCbCb-..~-

~

~

0-.CoCo~CoCo 0

0Cocl~-

Co Co

~-

Co 0

Co Cow 0

Co CD Co CD C CC) 23

~

~

CoC~~

23

~CC)~CDCoCoCo

-~

CC) Co Co

~

0 Co

~

~

Co CD Co

~

~,

-.- o o

~.oz'-~

o

~.

CD~CoCD

-~~CC)CoCoCD

~

"Co

~

Co'~~

COCD23O3~~CD~o

~

~Co

~

CD CC, o

-., CD~,

2323

~

~

~-

~

~.

~

-~

0CDC0C~~.,

~

CD

~

~~CoCo CD~~CoCDCo~&5

~0 Co

.CD CC) Co

~

~Co'-

Co Co~

Co..<

CO C0 P~CCD~Co~~

o Co ~-

~-.-C CC) C'<

0 C,

<~z-C, 0

0: CC)

CD ~<

~

C Co~0 0:

'0:

-o CC)

CC)

CC)

Cfl CC C

CC C

C C

Co Co Co Co Co Co Co Co

'0:

'0:

'-0:

~

Cn CD CD '0:

A A

A CD

_9,

=

l'J CCCCCCCCCCC,~-Oi-~--'

C, CC,

~

C A

A A

A A

A CD C,

C, C,

CCCCCCC,~CD-'CO1 PC, p999 CD

-J C

-C-(~)

C, C,

C,

CCCCC,

~

CC, CCC,~~

ow O~,

0),

(s),

N)C,0)C~)0)C3)0)-~

-CC)

~~N)0),

~~N)-~C0--'40.

A A

A A

A A

A A

CC, CCCCCCCCCCN)N)N)N)SC,~

CC, CC, C,

CC, C.~)

CD C))

0)-CC. ~

0)0)

, 0)0)

N) 0)0)

0)
0)

N)

0)

C, C,

CD 9CC Cl)

~

CD

-o

.CDi C

4o.

CC, CCCC,~~C, CN)CCN)

CC, CC, C,

CC, C))

C N),

N)N),

N),

A A

A A

A CCCCCC,-'CCCC,-'CC,-~N)N)~'C))CC~)

C, CC, C,

.- '-~

C,~-'N)-~'

CD c~

CD

~

C

-~

CD 0)

C) 01 CCCCC,-'CCCJ)C.oN)

C, CC, C,

N)C,)

CN)-'C~)C~)

C O)CcO CON),

AAAAAAAA

=

-~ -'

-S N)

N)

N) CD) CD)

-~

-S N)

C CD ~

~ ci:~

0-'

CD Co C.il ~

-~

'-C CD o ~<

Co~

CI) CD

~Co

~0' C/1~

(-xo TICD

~J 4

~

CI)

(~k) 0-Co

-~

CD 4Ž. 0 I-Co 0-

'-10~

0-CD 0

0Co p10 0-

-o

-o CD 0~

I 0

C 0-'

5:

-I, CD Cl)

CC)

C-0 0

0*

CCD

Appendix H - Subtidal Fishes Table H4.(continued). Subtidal fishes survey means (abundance per 50 x 4 x 2 m transect), standard deviations and annual means, Patton Cove Stations SC FO-1 (12), SC FO-2 (13), SC FO-3 (14).

EBenthic (continued)

Oxyjulis califomica 0.6 0.9 0.1 Hexagrammos decagrammus (Guy.)

<0.1 0.2 0.5 0.6 0.1 Sebastes serranoides

<0.1 0.2 0.3

.0.4

<0.1 0.2 0.2 0.3 0.1 Artedius spp.

0.2 0.3 0.3 0.4 0.2 0.4 0.1 Rhacochiilus vacca (juy.)

<0.1 0.2 0.3 -

0.4 0.1 Hypsurus calyi 0.3 0.6

<0.1 Cebidichthys violaceus

<0.1 0.2

<0.1 0.2

<0.1 0.2

<0.1 Scorpaenichthys marmnoratus (juv.)

0.2 0.3

.<0.1 0.2

<0.1 Brachyistius frenatus (juv.)

'0.2' 0.4

<0.1 Rhinogobiops nicholsi (juv.)

0.2 0.4

<0.1 Aulorhynchus flavidus

<0.1,I 0.2

<0.1 Sebastes melanops

<0.1 0.2

<0.1

  • Pleuronichthys coenosus

<0.1 0.2

<0.1 Sebastes chr'ysomelas (juv,)

<0.1 0.2

<0.1 Jordania zonope

<0.1 0.2

<0.1 Oxylebius pictus (juv.)

<0.1 0.2.

<0.1 ESLO2015-05 H-8