WI Pacific Gas and Electric Company" Adorn Peck Director Nuclear Engineering Diablo Canyon Power Plant P.O. Box 58 Anita Beach, CA 93424 805.545.6675 E-Mail:

ANPNl~pge.com December 2, 2015 PG&E Letter DCL-15-138 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C. 20555-0001 10 CFR 50.54(f)

Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Seismic Data Request from NRC - Southwest Research Institute

References:

1. PG&E Letter DCL-1 5-035, "Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Seismic Hazard and Screening Report," dated March 11, 2015 (ADAMS Accession No. ML15071A046)
2. PG&E Letter DCL-14-081, "Central Coastal California Seismic Imaging Project, Shoreline Fault Commitment," dated September 10, 2014, with Enclosure titled "Central Coastal California Seismic Imaging Project - Report to the California Public Utilities Commission," (ADAMS Accession No. ML14260A387)

Dear Mr. DiFrancesco:

On March 11, 2015, Pacific Gas and Electric Company (PG&E) submitted the Diablo Canyon Power Plant (DCPP) Seismic Hazards and Screening Report (SHSR),

"Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Seismic Hazard and Screening Report," (Reference 1) to the NRC.

The NRC and its contractor (Southwest Research Institute) conducted an audit of the Seismic Source Characterization (SSC) studies associated with the DCPP SHSR (ML15217A356) on August 26 and 27, 2015.

Subsequently, the NRC conducted an audit of the Ground Motion Characterization (GMC) studies associated with the DCPP SHSR (Reference ML15244B099) on September 11, 2015.

As a A member of the STARS (Strategic Teaming and Resource Sharing)

ALfiance Cattaway

  • Diabto Canyon
  • Pal~oVerde WoLf Creek AtO

Document Control Desk PG&E Letter DCL-15-138 December 2, 2015 Page 2 follow up to the SSC audit, as further clarified during the GMC audit, the staff requested additional data for their review.

The following specific information was requested by the staff to support their evaluation of the Half Graben structure as described in the Chapter 4 (Interpretation of Seismic-Reflection Data, Point Buchon to San Simeon Point) of the Central Coastal California Seismic Imaging Project (CCCSIP) Report (Reference 2):

Depth-corrected seismic reflection data - CM lines from COMAP 1986 PBS Lines from United States Geologic Survey (USGS) 2008 seismic survey PBS Lines from USGS 2009 seismic survey Bathymetric data - Multi-Beam Echo Sounder (MBES) bathymetric data within the area shown in Plate 7 from the CCCSlP report

  • Depth corrected interpreted horizons - The two mapped unconformities within the Half Graben basin, HG1 and HG2
  • Isopach map - The isopach map showing the thickness of the sediment section within the Half Graben basin Earthquake data - most recent interpretation of the hypocentral locations of these (Earthquake epicenters plotted on Plate 5) and any other events in the vicinity of the Half Graben structure The requested data is provided in the Attachment to the Enclosure, which includes two data disks.

The Enclosure describes the files contained on the two data disks in more detail.

PG&E makes no new or revised regulatory commitments (as defined by NEI 99-04) in this letter.

This letter includes no revisions to existing regulatory commitments.

If you have any questions, or require additional information, please contact Mr. Hossein Hamzehee at (805) 545-4720.

I have been delegated the authority of Barry S. Allen, Vice President - Nuclear Services, during his absence.

I state under penalty of perjury that the foregoing is true and correct.

Executed on December 2, 2015.

S incerely,*

Adam Peck Director, Nuclear Engineering A member of the STARS (Strategic Teaming and Resource Sharing)

Al.Liance

,CaLLaway DiabLo Canyon

  • Pal~oVerde
  • Wo!.fCreek

Document Control Desk December 2, 2015 Page 3 PG&E Letter DCL-1 5-1 38 mjrm/5065781 7-06/4557

Enclosure:

cc:

Diablo Distribution cc/enc: Marc L. Dapas, NRC Region IV Administrator Nicholas J. DiFrancesco, NRR/JLD Project Manager Thomas R. Hipschman, NRC Senior Resident Inspector Siva P. Lingam, NRR Project Manager Gonzalo L. Perez, Branch Chief, California Department of Public Health Frankie Vega, NRR/JLD Project Manager A member of the STARS (Strategic Teaming and Resource Sharing) Atllance Cattaway Diabto Canyon Palo Verde

  • Wotf Creek

Enclosure PG&E Letter DCL-1 5-1 38 Response to Seismic Data Request from NRC - Southwest Research Institute (Two Data Diskettes)

Attached are two data diskettes, labelled "GIS_data" and "SegY export", containing the following information:

A. Data Disk 1. "GIS Data" Contents The folder titled "GIS_Data" contains following subfolders:

1. Subfolder "DEMs":

Digital elevation models (DEMs) for two separate areas:

a. "DEM for Plate 7": This corresponds with the area shown on Plate 7 of Chapter 4 of the Central Coastal California Seismic Imaging Project (CCCSIP) Report (Reference 2).

The DEMs were compiled and resampled from many data sets. These datasets used to create the DEM for Plate 7 are listed in Table Al.

b. "DEM for site area":

This corresponds to the Diablo Canyon Power Plant (DCPP) Site Area.

The DEMs were compiled and resampled from many data sets. The datasets used to create the DEM for the DCPP Site Area are listed in Table A2.

2. Subfolder "Earthquake data":

Shapefile of the earthquake catalog provided by Dr. Jeanne Hardebeck (USGS) to PG&E in 2014.

Details about the catalog are provided in Appendix F of the DCPP Seismic Source Characterization report (Reference 3).

3. Subfolder "Sediment Thickness Contour":

Shapefile with the offshore isopach map, which is presented on Plate 7 of Chapter 4 of the CCCSIP Report (Reference 5).

This map was created by taking the difference in the two way travel time (TWTT) between the seafloor reflector and the interpreted top-of-rock, and using an assumed seismic velocity of 1600 meters per second.

1

Enclosure PG&E Letter DCL-1 5-1 38 Table Al - Data Sources for the Portion of the Offshore DEM on Plate 7 of CCCSIP Chapter 4 (Reference 2)

Layer file Description Title and Citation name southern calif NGDC's U.S. Coastal Relief Model (CRM) providing 3 arc seconds (roughly 90 meters)

Coastal Relief Model of the crm vl comprehensive view of the U.S. coastal zone integrating offshore bathymetry with land topography Southern California.

of the coastline.

NOAA, (2003)

Horizontal Coordinate System: World Geodetic System (WGS) 1984.

Ellipsoid Name: Geodetic Reference System (GRS) GRS-80 Available at: http~llwww.ngqdc. noaa~qovlmqlplcoastal/qrddasO6/qrddasO6.

htm port san luis One third arc-second DEM covering onshore and offshore region of Port San Luis, CA.

Port San Luis, CA 1/3 arc-public second OEM data including navd88.asc Horizontal Coordinate System: WGS 1984.

onshore and offshore OEM.

Vertical Coordinate System: North American Vertical Datum of 1988 (NAVD88)

NOAA (2011 ).

Port San Luis, CA 1/3 arc-second NAVD 88 Available at:

http://www ngdc. noaa.clov/dem/squareCetlGrid/downloadi3 164 Area 02 UTM One meter grid size onshore Hydro-flattened Bare Earth OEM data.

2009 - 2011 CA Coastal 10 B1 LiDAR Horizontal Coordinate System:

Universal Transverse Mercator (UTM) Zone 10, North American Conservancy Coastal Lidar Datum (NAD) NAD83 (2007). Vertical Coordinate System: NAVD88 Project:

Hydro-flattened Bare Earth DEM.

Available at:

NOAA (2012) https:/!catalog data.gQov/datasetl2009-20 11 -ca-coastal-conservancy-coastal-lidar-proiect-hydro-flattened-bare-earth-dem PG&E 2013 One meter grid size onshore LiDAR OEM data.

2009 -2011 CA Coastal LiDAR Conservancy Coastal Lidar Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Project:

Hydro-flattened Vertical Coordinate System: NAVD88 Bare Earth OEM.

NOAA (2012)

Available at:

http://www p~e. com/mybusiness/edusafety/systemworks/dcpp/SSHAC/leaacy documents/datasets/i ndex shtml 2

Enclosure PG&E Letter DCL-15-138 Table Al - Data Sources for the Portion of the Offshore DEM on Plate 7 of CCCSIP Chapter 4 (Reference 2)

Layer file Description Title and Citation name scc07 2mbathy Two meter and five meter cell size DEM grids including offshore multibeam bathymetry data sets.

Bathymetric DEM data scc07 5mallbt collected using multibeam, scc08 2mbathy Horizontal Coordinate System:

UTM Zone 10, NAD83 (1983).

sidescan and sub-bottom scc08 5mallbt Vertical Coordinate System:

NAVD88 sonar technologies by The scc09 2mbathy California Seafloor Mapping scc09 5mallbt Available at:

http://seafloor.otterlabs.orWqSFMLwebDATA SURVEYMAP.htm Project (CSMP).

Seafloor sccl0 2mbathy Mapping Lab of California sccl0 5mallbt State University Monterey sccl 1 2mbathy Bay (2009, 2010, and 2011 )

sccl 1 5mallbt scc12 2mbathy USGS UTM Two meter grid size offshore multibeam bathymetry data set published by USGS as Open-File Bathymetry and Acoustic NAD83 grid Report 201 3-1 225.

Backscatter Data - Estero Bay, California.

Open-File Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Report 201 3-1225, USGS Vertical Coordinate System: NAVD88 (2013)

Available at:

http:I//pubs. usgs.gov/of/201 3/1225/

3

Enclosure PG&E Letter DCL-15-138 Table A2-Data Sources for the DCPP Site Area DEM Layer file name Description Title and Citation port san luis One-third arc-second DEM covering onshore and offshore region of Port San Luis, CA.

public navd88.asc Horizontal Coordinate System: Geographic WGS 1984.

Vertical Coordinate System:

NAVD88 Port San Luis, CA 1/3 arc-Port San Luis, CA 1/3 arc-second NAVD 88 second DEM data including onshore and offshore DEM.

Available at: http://www. ngdc. noaa.qov/dem/sqluareCellGrid/download/3 164 NOAA (2011).

Area 02 UTM One meter grid size onshore Hydro-flattened Bare Earth OEM data.

10OC1 LiDAR Horizontal Coordinate System:

UTM Zone 10, NAD83 (2007).

)9 - 2011 CA Coastal Vertical Coordinate System:

NAVD88 Conservancy Coastal Lidar Project:

Hydro-flattened Available at: https://catalociqdata.,qov/dataset/2009-201 1-ca-coasta!-conservancy-coastal-lidar-Bare Earth DEM. NOAA rroiect-hydro-flattened-bare-earth-dem (2012)

PG&E 2010 One meter grid size onshore LiDAR OEM data.

2010 Diablo Canyon LiDAR LiDAR Survey.

PG&E (2010)

Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Vertical Coordinate System: NAVD88 Available at:

http~://www. pge. com/mybusiness/edusafety/systemworks/dcpp/SSHAClleqiacy documents/datasets

/index~shtml PG&E 2011 One meter grid size onshore LiDAR DEM data.

2011 Los Osos-Edna Valley LiDAR LiDAR Survey.

PG&E Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

(2011)

Vertical Coordinate System: NAVD88 Available at:

http://www.p qecom/mybusiness/edusafety/systemworks/dcpp/SSHAC/legacy documents/datasets

/index.shtml 4

Enclosure PG&E Letter DCL-15-138

___________Table A2-Data Sources for the DCPP Site Area DEM Layer file name Description Title and Citation PG&E 2013 One meter grid size onshore LiDAR DEM data.

San Simeon and Cambria LiDAR Faults LiDAR Survey.

Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

PG&E (2013)

Vertical Coordinate System:

NAVD88 Available at:

http ://www. pge. com/mybusiness/edusafety~systemworks/dcpp/SSHAC/legqacy documents/datasets

!index.shtml pb 25mbathy One meter, two meter, five meter and twenty-five meter cell size DEM grids including offshore Bathymetric DEM data pb 2mbathy multibeam bathymetry data sets.

collected using multibeam, cc bb lmbthy sidescan and sub-bottom cc bb 2mbthy Horizontal Coordinate System:

UTM Zone 10, NAD83 (1983).

sonar technologies by The cc bb 5mallbt Vertical Coordinate System:

NAVD88 California Seafloor Mapping cc bc lmbthy Project (CSMP).

Seafloor cc bc 2mbthy Available at: http://seafloor.otterlabs~orgqiSFMLwebDATA SURVEYMAP.htm Mapping Lab of California cc bc 5mallbt State University Monterey Bay (2009, 2010, and 2011) 5

Enclosure PG&E Letter DCL-1 5-1 38 B. Data Disk 2. "SeflY export" Contents The folder titled "SegY export" includes the following items in subfolders:

Seismic reflection profiles Interpreted seismic horizons HG1 and HG2 Interpreted seismic horizons Hi0, H30, and H40

  • Interpreted faults
1. Subfolder Seismic Reflection Profiles "COMAP Lines":

SegY files from the COMAP, 1986 Survey.

These seismic lines were interpreted as part of Chapter 4 of the OCCSIP report (Reference 2):

The following lines are included:

1986 COMAP Survey Lines 35 37 39 41 43 45 47 49 51 55 These lines are provided in the UTM coordinate system, meters, relative to the WGS 1984 horizontal datum.

They include seismic reflection amplitude data in TWTT.

None of these lines have been depth corrected.

6

Enclosure PG&E Letter DCL-1 5-138

2. Subfolder Seismic Reflection Profiles "PBS Lines": SegY files for the following seismic lines:

USGS 2008 Survey USGS 2009 Survey PBS-08B PBS-203 PBS-37A PBS-204 PBS-37T PBS-204A PBS-38A PBS-206 PBS-38T PBS-207 PBS-39A PBS-209 PBS-39T PBS-210 PBS-40 PBS-212 PBS-49 PBS-220 PBS-50 PBS-229 PBS-230 PBS-232 P BS-2 33 PBS-235 PBS-236 P BS-2 37 PBS-238 PBS-238A PBS-238B PBS-255 PBS-256 PBS-258 PBS-259 PBS-260 PBS-26 1

____PBS-278 These profiles were exported from IHS Kingdom software and are provided in the UTM coordinate system, meters, relative to the WGS 1984 horizontal datum.

They include seismic reflection amplitude data in TWTT.

None of these lines have been depth corrected.

Additional information about the Point Buchon Sparker (PBS) lines collected by the USGS is provided in "High-Resolution Seismic Reflection and Marine Magnetic Data Along the Hosgri Fault Zone, Central California" (Reference 4).

Please note that this list differs slightly from the supplemental data request.

Differences between the requested data and those provided on the enclosed data diskette are as follows:

a. Lines PBS-88, PBS-37AT, and PBS-39AT do not exist. There are apparently typographical errors on Plate 7 of Chapter 4 of the CCCSIP report 7

Enclosure PG&E Letter DCL-1 5-1 38 (Reference 5).

In lieu of these requested lines, we instead exported lines PBS-08B, PBS-37T, and PBS-39T.

b. We also included lines PBS-204 and PBS-238B, which are useful lines in this geographical extent.
3. Subfolder "Interpreted Seismic Horizons":

Six different interpreted seismic horizons, which were exported from IHS Kingdom software in the following ASCII format:

X Y

Line Trace Time Attribute The regional unconformities H10, H30, and H40 were originally mapped as part of the work described in the seismic stratigraphy report (Reference 1).

A description of the mapping is provided in that report.

These unconformities were subsequently used for interpretive work described in Chapter 3 of the CCCSIP Report (Reference 2) and the DCPP seismic source characterization report (Reference 3).

ASCII files containing these horizons as interpreted on the USGS seismic reflection profiles listed above (see sub-folder Seismic Reflection Profiles - PBS lines) are provided as.dat files.

Note that unconformity H40 is provided as two separate ASCII files, one that includes the part of the horizon located west of the primary traces of the Hosgri fault (named H40_west.dat) and one east of the primary traces of the Hosgri fault (named H40_East.dat).

Unconformities HG1 and HG2, which are described in Chapter 4 of the CCCSIP Report (Reference 2),

are also included as mapped on the COMAP and USGS lines listed above.

4. Subfolder "Interpreted Faults":

Three different ASCII files containing faults interpreted on the seismic reflection profiles listed in the subfolder Seismic Reflection Profiles - COMAP lines and PBS lines).

a.

File named "FAULTS SSHAC.dat":

Faults that were mapped on the USGS data as part of the work described in the seismic stratigraphy report (Reference 1) and Chapter 3 of the CCCSIP Report (Reference 2).

These faults are shown on the maps in the seismic source characterization report for the Diablo Canyon power plant (Reference 3).

These include the following faults:

LO1000, SS1000, HF1014, HF1015, HF1016, HF1023, HF1 024, HF1030, HF1031, HF1032, HF1033, HF1034, HF1 040, HF1045, and HF1051.

b.

File named "Faults Ch 4":

Named faults that were mapped on USGS data and COMAP data, as part of the work described in Chapter 4 of the CCCSIP Report (Reference 2).

8

Enclosure PG&E Letter DCL-15-138

c.

File named "Faults Ch 4 unassiqined":

Unassigned faults that were mapped on USGS data and COMAP data, as part of the work described in Chapter 4 of the CCCSIP Report (Reference 2).

9

Enclosure PG&E Letter DCL-1 5-1 38 References

1. PG&E (2013), "Stratigraphic Framework for Assessment of Fault Activity Offshore of the Central California Coast between Point San Simeon and Point Sal," PG&E Technical Report No. GEO.DCPP.TR.13.01
2. PG&E (2014), "Central Coastal California Seismic Imaging Project - Report to the California Public Utilities Commission," September 2014 (available at:

www. pge. com/enlsafetylsystemworks/dcpplseism icsafety/report. page)

3. PG&E (2015), "Seismic Source Characterization for Probabilistic Seismic Hazard Analysis for the Diablo Canyon Power Plant, San Luis Obispo, California," Report on the Results of the SSHAC Level 3 Study in Partial Compliance with NRC Letter 50.54(f), March 2015 (available at:

http:l/www.p~qe.com/enisafety/systemworks/dcpp/sshac/index.prage or http://www.pcie.com/dcpp-ltsp, see PG&E Seismic Source Characterization SSHAC

- Main Report

4. Sliter, R.W., Triezenberg, P.J., Hart, P.E., Watt, J.T., Johnson, S.Y., and Scheirer, D.S. (2010), "High-Resolution Seismic Reflection and Marine Magnetic Data Along the Hosgri Fault Zone, Central California," U.S. Geological Survey Open-File Report 2009-1100, Version 1.1 (available at:

pubs~usqsxgov/ofi2009i1 100)

5. PG&E (2014), Chapter 4: Interpretation of Seismic-Reflection Data, Point Buchon to San Simeon Point, PG&E Technical Report GEO.DCPP.TR.14.05:

in Central Coastal California Seismic Imaging Project (CCCSIP) Report to the California Public Utilities Commission (available at:

www. Dae. com/en/safetv/svstemworks/dcroD/seism icsafetv/reoort. Daae')

10

Enclosure Attachment PG&E Letter DCL-1 5-138 Attached Data Diskettes AB1632 - Disk 1 - GIS_data AB1632 - Disk 2 - SegY export 1

WI Pacific Gas and Electric Company" Adorn Peck Director Nuclear Engineering Diablo Canyon Power Plant P.O. Box 58 Anita Beach, CA 93424 805.545.6675 E-Mail:

ANPNl~pge.com December 2, 2015 PG&E Letter DCL-15-138 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C. 20555-0001 10 CFR 50.54(f)

Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Seismic Data Request from NRC - Southwest Research Institute

References:

1. PG&E Letter DCL-1 5-035, "Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Seismic Hazard and Screening Report," dated March 11, 2015 (ADAMS Accession No. ML15071A046)
2. PG&E Letter DCL-14-081, "Central Coastal California Seismic Imaging Project, Shoreline Fault Commitment," dated September 10, 2014, with Enclosure titled "Central Coastal California Seismic Imaging Project - Report to the California Public Utilities Commission," (ADAMS Accession No. ML14260A387)

Dear Mr. DiFrancesco:

On March 11, 2015, Pacific Gas and Electric Company (PG&E) submitted the Diablo Canyon Power Plant (DCPP) Seismic Hazards and Screening Report (SHSR),

"Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident: Seismic Hazard and Screening Report," (Reference 1) to the NRC.

The NRC and its contractor (Southwest Research Institute) conducted an audit of the Seismic Source Characterization (SSC) studies associated with the DCPP SHSR (ML15217A356) on August 26 and 27, 2015.

Subsequently, the NRC conducted an audit of the Ground Motion Characterization (GMC) studies associated with the DCPP SHSR (Reference ML15244B099) on September 11, 2015.

As a A member of the STARS (Strategic Teaming and Resource Sharing)

ALfiance Cattaway

  • Diabto Canyon
  • Pal~oVerde WoLf Creek AtO

Document Control Desk PG&E Letter DCL-15-138 December 2, 2015 Page 2 follow up to the SSC audit, as further clarified during the GMC audit, the staff requested additional data for their review.

The following specific information was requested by the staff to support their evaluation of the Half Graben structure as described in the Chapter 4 (Interpretation of Seismic-Reflection Data, Point Buchon to San Simeon Point) of the Central Coastal California Seismic Imaging Project (CCCSIP) Report (Reference 2):

Depth-corrected seismic reflection data - CM lines from COMAP 1986 PBS Lines from United States Geologic Survey (USGS) 2008 seismic survey PBS Lines from USGS 2009 seismic survey Bathymetric data - Multi-Beam Echo Sounder (MBES) bathymetric data within the area shown in Plate 7 from the CCCSlP report

  • Depth corrected interpreted horizons - The two mapped unconformities within the Half Graben basin, HG1 and HG2
  • Isopach map - The isopach map showing the thickness of the sediment section within the Half Graben basin Earthquake data - most recent interpretation of the hypocentral locations of these (Earthquake epicenters plotted on Plate 5) and any other events in the vicinity of the Half Graben structure The requested data is provided in the Attachment to the Enclosure, which includes two data disks.

The Enclosure describes the files contained on the two data disks in more detail.

PG&E makes no new or revised regulatory commitments (as defined by NEI 99-04) in this letter.

This letter includes no revisions to existing regulatory commitments.

If you have any questions, or require additional information, please contact Mr. Hossein Hamzehee at (805) 545-4720.

I have been delegated the authority of Barry S. Allen, Vice President - Nuclear Services, during his absence.

I state under penalty of perjury that the foregoing is true and correct.

Executed on December 2, 2015.

S incerely,*

Adam Peck Director, Nuclear Engineering A member of the STARS (Strategic Teaming and Resource Sharing)

Al.Liance

,CaLLaway DiabLo Canyon

  • Pal~oVerde
  • Wo!.fCreek

Document Control Desk December 2, 2015 Page 3 PG&E Letter DCL-1 5-1 38 mjrm/5065781 7-06/4557

Enclosure:

cc:

Diablo Distribution cc/enc: Marc L. Dapas, NRC Region IV Administrator Nicholas J. DiFrancesco, NRR/JLD Project Manager Thomas R. Hipschman, NRC Senior Resident Inspector Siva P. Lingam, NRR Project Manager Gonzalo L. Perez, Branch Chief, California Department of Public Health Frankie Vega, NRR/JLD Project Manager A member of the STARS (Strategic Teaming and Resource Sharing) Atllance Cattaway Diabto Canyon Palo Verde

  • Wotf Creek

Enclosure PG&E Letter DCL-1 5-1 38 Response to Seismic Data Request from NRC - Southwest Research Institute (Two Data Diskettes)

Attached are two data diskettes, labelled "GIS_data" and "SegY export", containing the following information:

A. Data Disk 1. "GIS Data" Contents The folder titled "GIS_Data" contains following subfolders:

1. Subfolder "DEMs":

Digital elevation models (DEMs) for two separate areas:

a. "DEM for Plate 7": This corresponds with the area shown on Plate 7 of Chapter 4 of the Central Coastal California Seismic Imaging Project (CCCSIP) Report (Reference 2).

The DEMs were compiled and resampled from many data sets. These datasets used to create the DEM for Plate 7 are listed in Table Al.

b. "DEM for site area":

This corresponds to the Diablo Canyon Power Plant (DCPP) Site Area.

The DEMs were compiled and resampled from many data sets. The datasets used to create the DEM for the DCPP Site Area are listed in Table A2.

2. Subfolder "Earthquake data":

Shapefile of the earthquake catalog provided by Dr. Jeanne Hardebeck (USGS) to PG&E in 2014.

Details about the catalog are provided in Appendix F of the DCPP Seismic Source Characterization report (Reference 3).

3. Subfolder "Sediment Thickness Contour":

Shapefile with the offshore isopach map, which is presented on Plate 7 of Chapter 4 of the CCCSIP Report (Reference 5).

This map was created by taking the difference in the two way travel time (TWTT) between the seafloor reflector and the interpreted top-of-rock, and using an assumed seismic velocity of 1600 meters per second.

1

Enclosure PG&E Letter DCL-1 5-1 38 Table Al - Data Sources for the Portion of the Offshore DEM on Plate 7 of CCCSIP Chapter 4 (Reference 2)

Layer file Description Title and Citation name southern calif NGDC's U.S. Coastal Relief Model (CRM) providing 3 arc seconds (roughly 90 meters)

Coastal Relief Model of the crm vl comprehensive view of the U.S. coastal zone integrating offshore bathymetry with land topography Southern California.

of the coastline.

NOAA, (2003)

Horizontal Coordinate System: World Geodetic System (WGS) 1984.

Ellipsoid Name: Geodetic Reference System (GRS) GRS-80 Available at: http~llwww.ngqdc. noaa~qovlmqlplcoastal/qrddasO6/qrddasO6.

htm port san luis One third arc-second DEM covering onshore and offshore region of Port San Luis, CA.

Port San Luis, CA 1/3 arc-public second OEM data including navd88.asc Horizontal Coordinate System: WGS 1984.

onshore and offshore OEM.

Vertical Coordinate System: North American Vertical Datum of 1988 (NAVD88)

NOAA (2011 ).

Port San Luis, CA 1/3 arc-second NAVD 88 Available at:

http://www ngdc. noaa.clov/dem/squareCetlGrid/downloadi3 164 Area 02 UTM One meter grid size onshore Hydro-flattened Bare Earth OEM data.

2009 - 2011 CA Coastal 10 B1 LiDAR Horizontal Coordinate System:

Universal Transverse Mercator (UTM) Zone 10, North American Conservancy Coastal Lidar Datum (NAD) NAD83 (2007). Vertical Coordinate System: NAVD88 Project:

Hydro-flattened Bare Earth DEM.

Available at:

NOAA (2012) https:/!catalog data.gQov/datasetl2009-20 11 -ca-coastal-conservancy-coastal-lidar-proiect-hydro-flattened-bare-earth-dem PG&E 2013 One meter grid size onshore LiDAR OEM data.

2009 -2011 CA Coastal LiDAR Conservancy Coastal Lidar Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Project:

Hydro-flattened Vertical Coordinate System: NAVD88 Bare Earth OEM.

NOAA (2012)

Available at:

http://www p~e. com/mybusiness/edusafety/systemworks/dcpp/SSHAC/leaacy documents/datasets/i ndex shtml 2

Enclosure PG&E Letter DCL-15-138 Table Al - Data Sources for the Portion of the Offshore DEM on Plate 7 of CCCSIP Chapter 4 (Reference 2)

Layer file Description Title and Citation name scc07 2mbathy Two meter and five meter cell size DEM grids including offshore multibeam bathymetry data sets.

Bathymetric DEM data scc07 5mallbt collected using multibeam, scc08 2mbathy Horizontal Coordinate System:

UTM Zone 10, NAD83 (1983).

sidescan and sub-bottom scc08 5mallbt Vertical Coordinate System:

NAVD88 sonar technologies by The scc09 2mbathy California Seafloor Mapping scc09 5mallbt Available at:

http://seafloor.otterlabs.orWqSFMLwebDATA SURVEYMAP.htm Project (CSMP).

Seafloor sccl0 2mbathy Mapping Lab of California sccl0 5mallbt State University Monterey sccl 1 2mbathy Bay (2009, 2010, and 2011 )

sccl 1 5mallbt scc12 2mbathy USGS UTM Two meter grid size offshore multibeam bathymetry data set published by USGS as Open-File Bathymetry and Acoustic NAD83 grid Report 201 3-1 225.

Backscatter Data - Estero Bay, California.

Open-File Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Report 201 3-1225, USGS Vertical Coordinate System: NAVD88 (2013)

Available at:

http:I//pubs. usgs.gov/of/201 3/1225/

3

Enclosure PG&E Letter DCL-15-138 Table A2-Data Sources for the DCPP Site Area DEM Layer file name Description Title and Citation port san luis One-third arc-second DEM covering onshore and offshore region of Port San Luis, CA.

public navd88.asc Horizontal Coordinate System: Geographic WGS 1984.

Vertical Coordinate System:

NAVD88 Port San Luis, CA 1/3 arc-Port San Luis, CA 1/3 arc-second NAVD 88 second DEM data including onshore and offshore DEM.

Available at: http://www. ngdc. noaa.qov/dem/sqluareCellGrid/download/3 164 NOAA (2011).

Area 02 UTM One meter grid size onshore Hydro-flattened Bare Earth OEM data.

10OC1 LiDAR Horizontal Coordinate System:

UTM Zone 10, NAD83 (2007).

)9 - 2011 CA Coastal Vertical Coordinate System:

NAVD88 Conservancy Coastal Lidar Project:

Hydro-flattened Available at: https://catalociqdata.,qov/dataset/2009-201 1-ca-coasta!-conservancy-coastal-lidar-Bare Earth DEM. NOAA rroiect-hydro-flattened-bare-earth-dem (2012)

PG&E 2010 One meter grid size onshore LiDAR OEM data.

2010 Diablo Canyon LiDAR LiDAR Survey.

PG&E (2010)

Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

Vertical Coordinate System: NAVD88 Available at:

http~://www. pge. com/mybusiness/edusafety/systemworks/dcpp/SSHAClleqiacy documents/datasets

/index~shtml PG&E 2011 One meter grid size onshore LiDAR DEM data.

2011 Los Osos-Edna Valley LiDAR LiDAR Survey.

PG&E Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

(2011)

Vertical Coordinate System: NAVD88 Available at:

http://www.p qecom/mybusiness/edusafety/systemworks/dcpp/SSHAC/legacy documents/datasets

/index.shtml 4

Enclosure PG&E Letter DCL-15-138

___________Table A2-Data Sources for the DCPP Site Area DEM Layer file name Description Title and Citation PG&E 2013 One meter grid size onshore LiDAR DEM data.

San Simeon and Cambria LiDAR Faults LiDAR Survey.

Horizontal Coordinate System:

UTM Zone 10, NAD83 (2011).

PG&E (2013)

Vertical Coordinate System:

NAVD88 Available at:

http ://www. pge. com/mybusiness/edusafety~systemworks/dcpp/SSHAC/legqacy documents/datasets

!index.shtml pb 25mbathy One meter, two meter, five meter and twenty-five meter cell size DEM grids including offshore Bathymetric DEM data pb 2mbathy multibeam bathymetry data sets.

collected using multibeam, cc bb lmbthy sidescan and sub-bottom cc bb 2mbthy Horizontal Coordinate System:

UTM Zone 10, NAD83 (1983).

sonar technologies by The cc bb 5mallbt Vertical Coordinate System:

NAVD88 California Seafloor Mapping cc bc lmbthy Project (CSMP).

Seafloor cc bc 2mbthy Available at: http://seafloor.otterlabs~orgqiSFMLwebDATA SURVEYMAP.htm Mapping Lab of California cc bc 5mallbt State University Monterey Bay (2009, 2010, and 2011) 5

Enclosure PG&E Letter DCL-1 5-1 38 B. Data Disk 2. "SeflY export" Contents The folder titled "SegY export" includes the following items in subfolders:

Seismic reflection profiles Interpreted seismic horizons HG1 and HG2 Interpreted seismic horizons Hi0, H30, and H40

  • Interpreted faults
1. Subfolder Seismic Reflection Profiles "COMAP Lines":

SegY files from the COMAP, 1986 Survey.

These seismic lines were interpreted as part of Chapter 4 of the OCCSIP report (Reference 2):

The following lines are included:

1986 COMAP Survey Lines 35 37 39 41 43 45 47 49 51 55 These lines are provided in the UTM coordinate system, meters, relative to the WGS 1984 horizontal datum.

They include seismic reflection amplitude data in TWTT.

None of these lines have been depth corrected.

6

Enclosure PG&E Letter DCL-1 5-138

2. Subfolder Seismic Reflection Profiles "PBS Lines": SegY files for the following seismic lines:

USGS 2008 Survey USGS 2009 Survey PBS-08B PBS-203 PBS-37A PBS-204 PBS-37T PBS-204A PBS-38A PBS-206 PBS-38T PBS-207 PBS-39A PBS-209 PBS-39T PBS-210 PBS-40 PBS-212 PBS-49 PBS-220 PBS-50 PBS-229 PBS-230 PBS-232 P BS-2 33 PBS-235 PBS-236 P BS-2 37 PBS-238 PBS-238A PBS-238B PBS-255 PBS-256 PBS-258 PBS-259 PBS-260 PBS-26 1

____PBS-278 These profiles were exported from IHS Kingdom software and are provided in the UTM coordinate system, meters, relative to the WGS 1984 horizontal datum.

They include seismic reflection amplitude data in TWTT.

None of these lines have been depth corrected.

Additional information about the Point Buchon Sparker (PBS) lines collected by the USGS is provided in "High-Resolution Seismic Reflection and Marine Magnetic Data Along the Hosgri Fault Zone, Central California" (Reference 4).

Please note that this list differs slightly from the supplemental data request.

Differences between the requested data and those provided on the enclosed data diskette are as follows:

a. Lines PBS-88, PBS-37AT, and PBS-39AT do not exist. There are apparently typographical errors on Plate 7 of Chapter 4 of the CCCSIP report 7

Enclosure PG&E Letter DCL-1 5-1 38 (Reference 5).

In lieu of these requested lines, we instead exported lines PBS-08B, PBS-37T, and PBS-39T.

b. We also included lines PBS-204 and PBS-238B, which are useful lines in this geographical extent.
3. Subfolder "Interpreted Seismic Horizons":

Six different interpreted seismic horizons, which were exported from IHS Kingdom software in the following ASCII format:

X Y

Line Trace Time Attribute The regional unconformities H10, H30, and H40 were originally mapped as part of the work described in the seismic stratigraphy report (Reference 1).

A description of the mapping is provided in that report.

These unconformities were subsequently used for interpretive work described in Chapter 3 of the CCCSIP Report (Reference 2) and the DCPP seismic source characterization report (Reference 3).

ASCII files containing these horizons as interpreted on the USGS seismic reflection profiles listed above (see sub-folder Seismic Reflection Profiles - PBS lines) are provided as.dat files.

Note that unconformity H40 is provided as two separate ASCII files, one that includes the part of the horizon located west of the primary traces of the Hosgri fault (named H40_west.dat) and one east of the primary traces of the Hosgri fault (named H40_East.dat).

Unconformities HG1 and HG2, which are described in Chapter 4 of the CCCSIP Report (Reference 2),

are also included as mapped on the COMAP and USGS lines listed above.

4. Subfolder "Interpreted Faults":

Three different ASCII files containing faults interpreted on the seismic reflection profiles listed in the subfolder Seismic Reflection Profiles - COMAP lines and PBS lines).

a.

File named "FAULTS SSHAC.dat":

Faults that were mapped on the USGS data as part of the work described in the seismic stratigraphy report (Reference 1) and Chapter 3 of the CCCSIP Report (Reference 2).

These faults are shown on the maps in the seismic source characterization report for the Diablo Canyon power plant (Reference 3).

These include the following faults:

LO1000, SS1000, HF1014, HF1015, HF1016, HF1023, HF1 024, HF1030, HF1031, HF1032, HF1033, HF1034, HF1 040, HF1045, and HF1051.

b.

File named "Faults Ch 4":

Named faults that were mapped on USGS data and COMAP data, as part of the work described in Chapter 4 of the CCCSIP Report (Reference 2).

8

Enclosure PG&E Letter DCL-15-138

c.

File named "Faults Ch 4 unassiqined":

Unassigned faults that were mapped on USGS data and COMAP data, as part of the work described in Chapter 4 of the CCCSIP Report (Reference 2).

9

Enclosure PG&E Letter DCL-1 5-1 38 References

1. PG&E (2013), "Stratigraphic Framework for Assessment of Fault Activity Offshore of the Central California Coast between Point San Simeon and Point Sal," PG&E Technical Report No. GEO.DCPP.TR.13.01
2. PG&E (2014), "Central Coastal California Seismic Imaging Project - Report to the California Public Utilities Commission," September 2014 (available at:

www. pge. com/enlsafetylsystemworks/dcpplseism icsafety/report. page)

3. PG&E (2015), "Seismic Source Characterization for Probabilistic Seismic Hazard Analysis for the Diablo Canyon Power Plant, San Luis Obispo, California," Report on the Results of the SSHAC Level 3 Study in Partial Compliance with NRC Letter 50.54(f), March 2015 (available at:

http:l/www.p~qe.com/enisafety/systemworks/dcpp/sshac/index.prage or http://www.pcie.com/dcpp-ltsp, see PG&E Seismic Source Characterization SSHAC

- Main Report

4. Sliter, R.W., Triezenberg, P.J., Hart, P.E., Watt, J.T., Johnson, S.Y., and Scheirer, D.S. (2010), "High-Resolution Seismic Reflection and Marine Magnetic Data Along the Hosgri Fault Zone, Central California," U.S. Geological Survey Open-File Report 2009-1100, Version 1.1 (available at:

pubs~usqsxgov/ofi2009i1 100)

5. PG&E (2014), Chapter 4: Interpretation of Seismic-Reflection Data, Point Buchon to San Simeon Point, PG&E Technical Report GEO.DCPP.TR.14.05:

in Central Coastal California Seismic Imaging Project (CCCSIP) Report to the California Public Utilities Commission (available at:

www. Dae. com/en/safetv/svstemworks/dcroD/seism icsafetv/reoort. Daae')

10

Enclosure Attachment PG&E Letter DCL-1 5-138 Attached Data Diskettes AB1632 - Disk 1 - GIS_data AB1632 - Disk 2 - SegY export 1