ML15343A339
| ML15343A339 | |
| Person / Time | |
|---|---|
| Site: | Zion File:ZionSolutions icon.png |
| Issue date: | 12/10/2015 |
| From: | John Hickman Reactor Decommissioning Branch |
| To: | Sauger J ZionSolutions |
| John B. Hickman, 301-415-3017 | |
| References | |
| TAC L53045, TAC L53046 | |
| Download: ML15343A339 (46) | |
Text
December 10, 2015 Mr. John Sauger General Manager Zion Restoration Project ZionSolutions, LLC.
101 Shiloh Boulevard Zion, IL 60099-2797
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE LICENSE TERMINATION PLAN FOR ZION NUCLEAR POWER STATION, UNITS 1 AND 2 (TAC NOS. L53045 AND L53046)
Dear Mr. Sauger:
By letter dated December 19, 2014, you submitted a request for approval of the Zion License Termination Plan. We have reviewed your request and have some additional information that will be needed to complete our review. The additional information requested is enclosed.
Should you have any questions regarding this action please contact me at 301-415-3017 or John.Hickman@nrc.gov.
Sincerely,
/RA/
John B. Hickman, Project Manager Reactor Decommissioning Branch Division of Decommissioning, Uranium Recovery, and Waste Programs Office of Nuclear Material Safety and Safeguards Docket Nos.: 50-295 and 50-304 License Nos.: DPR-39 and DPR-49
Enclosure:
Request for Additional Information cc:
w/enclosure Zion Service List
ML15343A339 OFFICE NMSS/PM NMSS/LA NMSS/BC NMSS/PM NAME J. Hickman C. Holston B. Watson J. Hickman DATE 12/10/15 12/10/15 12/10/15 12/10/15
Zion License Termination Plan Request for Additional Information PAB Zion RAIs Chapter 2
- 1. Comment: The determination of background values for Cs-137 needs clarification.
Basis: Section 2.3.1 summarizes the three background studies performed at the site (February 2012 ESCSG Study, March 2012 Crib House Study, and July 2012 ZionSolutions Soil Study). During the first study in February of 2012, 15 samples of concrete, asphalt and soil were collected from the Vertical Concrete Cask Construction area. This study determined that only natural radioactivity was detected. The second study, during which concrete core samples were taken from the Crib House, also determined that only natural radioactivity was detected. In the third study of soil samples from Hosah Park, Cs-137 was identified in addition to naturally occurring radionuclides.
In the Hosah Park study, 30 soil sample locations were chosen where static measurements were taken, as well as surface and subsurface volumetric samples. It is postulated that the Cs-137 is attributable to global fallout. The License Termination Plan (LTP) states that while there did appear to be evidence of soil disturbance at Hosah Park, the evidence suggested that this occurred in the past and the land has been undisturbed for a number of years. The study concluded that the majority of the soil samples from Hosah Park were from disturbed soils. The Hosah Park results are summarized in Table 2-10, which shows an average of 0.0626 pCi/g and a maximum of 0.241 pCi/g.
Section 2.3.1.4 of the LTP states The soil sample data compiled in the TSD concludes that the majority of the soil samples taken for the background studies were from disturbed soils. The Hosah Park data as well as the data obtained during the ESCSG study corresponded with documented fallout levels from disturbed soil at sites in Massachusetts, New York and Pennsylvania. Consequently, predicted ranges for background concentrations of Cs-137 were established for disturbed soils as well as undisturbed soils based on literature. These ranges are presented in Table 2-11.
The upper Cs-137 concentration for each category was used as the investigation levels for non-impacted open land survey units. The upper Cs-137 concentration for disturbed, non-drainage in Table 2-11 was used as the investigation level for Class 2 and 3 open land area survey units.
Section 2.3.1.4 of the LTP suggests that the background study data from the Hosah Park and ESCSG study corresponded to global fallout levels; the LTP does not provide a basis for why this conclusion was reached even though Cs-137 was not found in the ESCSG Study or Crib House Study. The upper values of global fallout ranges were assigned as investigation levels for Cs-137 when initially characterizing the survey units.
Table 2-11 provides Investigative Levels for Cs-137 Based on Background Studies. The upper value for undisturbed soil is 2.8 pCi/g or 0.66 pCi/g for a drainage or non-drainage area respectively. The upper value for disturbed soil in drainage area is 1.67 pCi/g. The upper value for a disturbed, non-drainage area, which was used for Class 2 and 3 open land area survey units, is 0.34 pCi/g. These upper values are well above the average of 0.0626 pCi/g or maximum of 0.241 pCi/g found in Hosah Park. The LTP does not provide a basis for using the upper values of the global fallout ranges from Massachusetts, New York and Pennsylvania, as opposed to the site-specific data.
NUREG 1757 Vol. 2, Rev. 1, Section A.3.2, providing guidance on soil reference areas, states that if there is a choice of possible reference areas with similar soil types, consideration should be given to selecting reference areas that are most similar in terms of other physical, chemical, geological, and biological characteristics. Section A.3.4 provides additional guidance on differences in background areas.
Path Forward:
Provide a basis for why the ESCGG study corresponds to documented global fallout ranges, even though Cs-137 was not found in the ESCSG study; Provide a basis for assuming the upper values of the global fallout ranges from Massachusetts, New York and Pennsylvania as investigation levels, as opposed to the site-specific background reference data; Provide "Determination of Radionuclide Activity Concentrations in Soils in Non-Impacted Soils Adjacent to the Zion Nuclear Station" (Reference 2-21); and, Provide ZionSolutions TSD 13-004, "Examination of Cs-137 Global Fallout In Soils At Zion Station" (Reference 2-22).
- 2. Comment: The use of background values in the Final Status Survey (FSS) compliance determination should be clarified.
Basis: Chapter 2 of the LTP discusses the background studies performed. The LTP (see Section 5.6.4.2 and Section 5.10) states that the Sign Test will be applied for open land survey units and buried piping when demonstrating compliance with the unrestricted release criteria without subtracting background. However, the licensee reserves the option to use the WRS test where background is a significant fraction of the Derived Concentration Guideline Levels (DCGL)w. The LTP does not provide enough detail regarding how the decision will be made to use the Sign Test or the WRS test or which background reference area will correspond to each survey unit.
Path Forward:
Provide a detailed example on how the decision to use the Sign Test or the WRS test within a survey unit will be determined; Provide the background reference area that will be applied in the FSS in each survey unit should the WRS test be used. This may be provided as an addendum to Table 2-3 and Table 2-4 which lists each survey unit, or (assuming reference areas are consistent across types of survey units) in a separate table which categorizes the types of survey units and their corresponding background reference area (e.g.,
Impacted Structures and Systems will use the Crib House Background Reference Area.); and, Provide Energy Services Commercial Services Group Report CS-RS-PN-028, Background Reference Area Report - Zion Nuclear Power Station, - February 2012 (Reference 2-20).
- 3. Comment: The definition of investigation levels in the FSS should be clarified.
Basis: Section 2.3.1.4 of the LTP defines investigation levels for Cs-137 as the upper range of the global fallout values for open land survey units. However, Section 5.7.1.1 states that The investigation levels may be based on the DCGLw, a fraction of the DCGLw, or the DCGLEMC, depending upon the detection capability (instrument and surveyor) to identify radioactivity, and investigation levels were further discussed in Section 5.6.4.6 and Table 5-13. Additionally, Section 5.10 discussing the FSS data assessment states, Survey results will be converted to appropriate units of measure (e.g., dpm/100 cm2, pCi/g) and compared to investigation levels to determine if the action levels for investigation have been exceeded. Measurements exceeding investigation action levels will be investigated. If confirmed within a Class 1 survey unit, the location of elevated concentration may be evaluated using the EMC, or the location may be remediated and re-surveyed. If measurements exceeding investigation action levels are confirmed within a Class 2 or 3 survey unit, in most cases, the entire survey unit will be reclassified and a re-survey performed consistent with the change in classification. It is not clear if the licensee is using the term investigation level consistently when referring to the surveys that were done for initial characterization versus the FSS, and the additional reference to an investigation action level should be clarified.
The investigation levels for FSS are defined in Table 5-13, but this table does not seem to include the investigation level discussed on pg 5-43 In addition, if during the performance of FSS, the analysis of a surface soil sample, or the results of a surface gamma scan indicates the potential presence of residual radioactivity at a concentration of 75 percent of the subsurface DCGLw, then additional biased subsurface soil sample(s) will be taken within the area of concern as part of the investigation.
Path Forward:
Clarify if Table 5-13 includes all the investigation level(s) that will be used in the FSS and add any additional investigation levels not included to Table 5-13; and Clarify the usage of investigation levels in Chapter 2 of the LTP versus investigation levels as discussed in Section 5.6.4.6.
- 4. Comment: The use of Cs-137 global fallout values as an investigation level during site characterization and initial survey unit classification needs clarification.
Basis: Section 2.3.1.4 of the LTP states that the upper values of global fallout ranges were assumed as background for Cs-137 when characterizing the open land survey units. However, it is not clear how this assumption impacted the initial classification of survey units (if at all).
It is also not clear if the global fallout levels were also assumed as background in characterizing survey units consisting of concrete, asphalt, or piping. NUREG 1757 Vol.
2, Section A.3.3, states that when there are different materials with substantially different backgrounds in a survey unit, the licensee may use a reference area that is a non-impacted room with roughly the same mix of materials as the survey unitIf a survey unit contains several different materials, but one material is predominant or if there is not too great a variation in background among materials, a background from a reference area containing only a single material may still be appropriate. However, the licensee should demonstrate that the selected reference area will not result in underestimating the residual radioactivity on other materials. The LTP suggests that the Hosah Park soil background reference area will be applied for the open land areas.
It is not clear if the global fallout values will be assumed for background in other materials such as concrete, asphalt, or piping.
Table 2-31 summarizes the characterization for Class 3 Open Land Survey Units. The footnote on Table 2-31 (pg 2-153) for Survey Unit 10220C (south of the Radiological Restricted Area) indicates that while 41 out of 55 samples exceeded the MDC for Cs-137, with the maximum being 1.14 pCi/g Cs-137, an investigation concluded that the elevated levels of Cs-137 are due to global fallout. However, the details of this investigation for Survey Unit 10220C do not seem to be discussed in the body of the LTP.
Path Forward:
Define the term investigation level as applied during initial classification of survey units; Clarify how the investigation level may impact whether an open land survey unit area is classified as non-impacted versus impacted; Evaluate whether initial classifications would change if actual site data were used instead of global fallout data; Describe the analysis that was performed to conclude that the non-impacted areas are indistinguishable from background; and, Provide the investigation details that concluded that the elevated levels of Cs-137 in Survey Unit 10220C are due to global fallout.
Chapter 3
- 5. Comment: More information is needed regarding the backfilling of the basements.
Basis: In Chapter 3, it is stated that the concrete debris suitable for reuse and or/clean fill will be used to backfill the basements and that the top three feet of fill will be soil only.
Chapter 3 also states that the concrete debris will be processed to ensure that the pieces are less than 10 inches in diameter. In Chapter 6, it is stated that, The specific composition of the backfill has not yet been determined but is expected to be some combination of sand and debris resulting from building demolition that is designated for beneficial reuse as clean hard fill.
Based on the information in the LTP, it is not clear what the composition of the backfill material will be. Additionally, it is not clear what material is included in the clean fill and what type of soil will be used in the backfill. Also, information was not provided on how the backfill material will be placed to ensure that voids are filled adequately.
This information is needed because the projected release and transport of the residual contamination in the basements depends on the type of material used and manner of the backfilling. Additionally, the long term stability of the backfilled basements depends on the way the basements are backfilled.
Path Forward:
Describe the composition of the backfill for the basement, including the relative ratio of materials that will be used; and, Also describe the method that will be used to ensure that the material is clean and that all voids are filled. If more than one option is being considered for the backfill, please provide a description of all possible options.
- 6. Comment: More information is needed on the filling of abandoned piping with grout or fill.
Basis: Chapter 3 states that all remaining buried and piping embedded in concrete will be surveyed for compliance with the unrestricted release criteria prior to being isolated, abandoned in place and filled with grout or fill as appropriate. However, it is not clear how the licensee will decide whether to fill the pipes with grout or fill, or to not fill the pipes. A description of the grout or fill that may be used is also not provided.
Path Forward:
Provide a description of the process that will be used to determine whether piping is filled with grout or fill, or not filled; and, Provide description of any grout or fill that may be used, including the relative ratio of materials that may be included in the fill or grout.
Chapter 6
- 7. Comment: Additional information is needed to evaluate the Radionuclides of Concern (ROC).
Basis: Section 6.5.2 of the LTP discusses the ROC. The LTP provides an initial suite of radionuclides in Table 6-2. However, it does not provide enough details regarding the starting list of radionuclides and why certain radionuclides were eliminated from the starting list to produce the initial suite. Section 2.3.2 states, Based on the elimination of some of the theoretical neutron activation products, noble gases and radionuclides with a half-life less than 2 years, an initial suite of potential ROC for the decommissioning of the ZNPS was prepared. NUREG 1757 Vol 2 Appendix O, Question 1 states that, The licensee should also consider historical fuel performance, operational history, and time since shutdown when defining the ROCs.
Path Forward:
Provide additional details regarding the process for defining the initial suite of ROCs, including the consideration of historical fuel performance, operational history, and time since shutdown; Provide ZionSolutions TSD 11-001, "Potential ROC during the Decommissioning of Zion Station" (Reference 6-9); and, Provide ZionSolutions TSD 14-019, "ROC for Soil and Basement Fill Model Source Terms" (Reference 4-15).
- 8. Comment: Additional information is needed to evaluate the dose contribution from insignificant radionuclides and subsequent adjustments to the basement dose factors and soil DCGLs.
Basis: NRC staff considers radionuclides and exposure pathways that contribute no greater than 10 percent of the dose criteria (2.5 mrem/yr) to be insignificant contributors.
NUREG 1757, Vol 2, Appendix O, Question 2, states that It is incumbent on the licensee to have adequate characterization data to support and document the determination that some radionuclides may be deselected from further detailed consideration in planning the FSS. Radionuclides that are undetected may also be considered insignificant, as long as the Minimum Detectable Concentrations (MDCs) are sufficient to conclude that the dose contribution is less than 10 percent of the dose criterion (i.e., with the assumption that the radionuclides are present at the MDCs).
The LTP describes the dose contribution from insignificant ROCs from buildings (Table 6-2 and Table 6-3), and soil (Table 6-19). The dose contribution for ROCs in structures is calculated by multiplying the percent radionuclide activity (for either Containment or Auxiliary Basements in Table 6-2) by the BFM dose factors determined in TSD-14-010.
Section 6.5.2.3 states, In TSD 14-019, the dose factors were used to calculate the relative dose (i.e., percentage) from each radionuclide given their respective mixture percentages. The mixture percentages for the initial suite of ROCs for Containment and Auxiliary Basement concrete were developed in TSD 14-019 using the results of the core sample analyses. Section 6.5.2.2 states, The mixture fractions for the non-gamma emitters, or Hard-to-Detect (HTD) radionuclides, were determined by analyzing selected cores from the Containment and Auxiliary Basements that contained the highest radionuclide concentrations based on gamma spectroscopy. The use of cores with higher concentrations was required to ensure that the percentage assigned to HTD radionuclides were not overly influenced by the MDC values which was the only concentration data available for the majority of the HTD radionuclides in the initial suite.
A similar approach was applied for determining the dose contribution from each ROC for soil. The LTP describes 10 soil samples that were analyzed for HTDs (Section 2.3.5.1 and Section 2.3.5.2). However, section 6.8.2 states, there were very few positive soil sample results identified during characterization and the levels were insufficient to provide a meaningful evaluation of HTD radionuclides. Therefore, the radionuclide mixture for the Auxiliary Basement cores was applied to soil for planning purposes. The percent mixture for the Auxiliary Basement was multiplied by the dose to source ratios for soil in TSD-14-10 to calculate dose contribution from each ROC for soil.
There are several issues with the licensees approach to calculating dose from insignificant radionuclides. First, it is not clear that the values assumed for the concentrations (mixture percent) are appropriate. These should represent the likely concentration of the insignificant radionuclides based on characterization data or detection limits. This information may be included in the reference TSD 14-010 or TSD 14-019. Second, the combined dose from the insignificant radionuclides must not exceed 2.5 mrem/yr. The licensee multiplies the percent activity by a dose to source ratio to calculate a dose and then finds the ratio of each ROC to the total dose. The ratios are presented, but the actual expected doses from each ROC are not provided. It is not clear if the existing characterization data supports the determination that the dose from all the insignificant radionuclides for all pathways does not exceed 2.5 mrem/yr.
Furthermore, it is not clear how the expected annual dose in mrem will be calculated from characterization data.
Clarifying Comments:
The dose contribution from insignificant radionuclides for soil DCGLs reported in TSD 14-010 is inconsistent with that reported in the LTP. The LTP states that the insignificant radionuclides contribute 0.171 percent of the dose from soil. This percentage is based on the Auxiliary concrete mixture fractions listed in Table 6-2 of the LTP, and are calculated using the methods described in TSD 14-019 and Section 6.5.2. TSD-14-010 states that the DCGLs were adjusted to account for the 0.41 percent dose contribution from insignificant contributors as calculated in TSD 019.
Path Forward:
Provide the technical basis for the Percent Activity for the Containment and Auxiliary Basement listed in Table 6-2 (reference TSD 14-019). For example, show how the core data was aggregated to define the percent radioactivity for each ROC; Provide justification for using the cores from the Containment and Auxiliary Basements that contained the highest radionuclide concentrations based on gamma spectroscopy for determining the mixture fractions of non-gamma emitting radionuclides if it is not already contained in the reference requested; Provide additional consideration that will be utilized, if necessary, to justify consistent relative abundance levels site-wide throughout the decommissioning process, and to justify further reductions in overall contamination during decommissioning.
Furthermore, provide basis that decommissioning activities will not result in increased relative concentrations of insignificant radionuclides; Provide the detailed calculations to determine the percent annual doses in Table 6-3 and Table 6-19 if they are not already provided in the reference requested; Calculate the potential dose (mrem) from the initial suite of 26 ROCs in soil assuming that the radionuclides which were not measureable (above the instrument MDC) are present at their respective MDCs, and assuming other radionuclides are present at levels supported by the characterization data for soil in open land survey units; Calculate the potential dose (mrem) from the initial suite of 26 ROCs in building structures assuming that the radionuclides which were not measureable (above the instrument MDC) are present at their respective MDCs, and assuming other radionuclides are present at levels supported by the characterization data for building structures and systems; Provide the detailed calculations used to adjust the DCGL values from those provided in the RESRAD summary reports to those listed in Table 6-27; and, Provide a technical basis for the IC Dose Adjustment Factors in Equation 6-4 and the detailed calculations used to adjust the Basement Dose Factors in Table 6-18.
- 9. Comment: Additional information is needed on the process for potentially revising the assumed mixture of radionuclides.
Basis: The Auxiliary Basement radionuclide mixture is assumed for several other buildings as well as soil for planning purposes due to lack of characterization data.
Section 6.5.2.2 states, As additional radioactive material from different sources (i.e.
processed SFP water) is introduced, this could potentially result in a mixture that is different from the Auxiliary Building concrete mixture. The mixture in the SFP/Transfer Canals could also be somewhat different than the Auxiliary Building due to the source of potential contamination, i.e., fuel pool water leaking into the concrete under the liner.
However, the mixture in both the Circulating Water Discharge Tunnel and the SFP/Transfer Canal is expected to be primarily Cs-137 as in the other Basements.
Therefore, the Auxiliary Basement mixture is considered reasonable for application to these two structures for planning purposes. The mixtures in these two Basements will be reviewed as continued characterization data is collected from these areas (see LTP Chapter 5, section 5.1).
Path Forward:
Provide information on how the mixtures in the containment and auxiliary basements will be reviewed (i.e., what would trigger a recalculation of the dose contribution from insignificant radionuclides and therefore a revision to the adjusted DCGLs).
- 10. Comment: Additional information is necessary to evaluate the site-specific Kd parameters applied in the RESRAD and DUST-MS models.
Basis: Section 6.9.1 states, Kd values for site soil (sand) were selected based on the review provided by Brookhaven National Laboratory in TSD 14-004 (see Table 6-20).
Additionally, Section 6.6.1.1 states that site-specific Kd analyses performed by Brookhaven National Laboratory as documented in two reports, ZionSolutions TSD 14-017, Sorption (Kd) Measurements on Cinder Block and Grout in Support of Dose Assessments for Zion Nuclear Station Decommissioning, and ZionSolutions TSD 14-020, Sorption (Kd) measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning. However, TSD 14-004, TSD 14-017, and TSD 14-020 have not been provided.
Also, as described in Section 6.4.4 of the LTP, the Kd values assumed in the calculation of the groundwater exposure factor calculations were the same as those assigned in the DUST-MS model. The text describes the selection process for the Kd values as being conservative. However, low Kd values generally maximize the release and transport of radionuclides through groundwater, while high Kd values generally maximize the concentration of the radionuclides in soil that is irrigated with contaminated groundwater, which in turn maximizes the concentration in plants and ingestion doses. The use of Kd values that were conservatively determined based on the release from the source term may be non-conservative when used in the analysis of the surface soil concentrations.
Path Forward:
Provide justification that the Kd values selected are appropriate for use in the calculation of the surface soil concentrations.
Please provide the following references and any key references these documents cite:
ZionSolutions Technical Support Document 14-004, Brookhaven National Laboratory (BNL), Recommended Values for the Distribution Coefficient (Kd) to be used in Dose Assessments for Decommissioning the Zion Nuclear Power Plant; ZionSolutions Technical Support Document 14-017, Brookhaven National Laboratory (BNL), Sorption (Kd) Measurements on Cinder Block and Grout in Support of Dose Assessments for Zion Nuclear Station Decommissioning; and, ZionSolutions Technical Support Document 14-020, Brookhaven National Laboratory (BNL), Sorption (Kd) measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning.
- 11. Comment: Additional information is necessary to evaluate the Soil Area Factors (AFs) listed in Table 5-7, 5-8 and Table 6-28, 6-29.
Basis: The Soil Area Factors are provided in Tables 5-7, 5-8, 6-28, and 6-29. These are calculated using RESRAD for each ROC and for source area sizes ranging from 1 m2 up to the full source area of 64,500 m2. However, not enough information is provided to reproduce the AFs.
Path Forward:
Please provide reference TSD 14-019 and associated RESRAD Summary Reports in TSD 14-011 for calculating AFs.
- 12. Comment: Additional information is necessary to evaluate the Buried Pipe DCGLs.
Basis: Section 6.12 discusses the development of buried pipe DCGLs, but the conceptual model assumed to derive the DCGLs does not seem consistent with the expected configuration of the residual contamination following decommissioning activities. In the calculation of these DCGL values, it is assumed that the pipe is filled with soil that has an activity of radionuclides equal to the Surface Soil DCGL values.
These volumetric DCGL values were then converted to an aerial value on the interior surface of the pipe, which is effectively equivalent to assuming a dilution of the material on the surface of the pipe over the whole volume of the pipe. The pipes that remain on site at the time of license termination may not be filled with soil (or grouted), so it is not clear that this conceptual model applies. In addition, the dose to an individual may be different from a thin skin of contamination on the surface of the pipe than from a volumetric source containing the same amount of activity.
The conceptual model attempts to account for the potential dose from the pipes being excavated and reused through the buried pipe excavation scenario. The amount of material assumed to be exhumed is limited to a 20 m length of pipe (based on a basement which is 10 m x 20 m). However, the possibility of an intruder encountering more than one pipe in a single basement is not discussed.
The buried pipe DCGL derivation attempts to account for the contribution of the pipes to the dose for the resident through the In-situ Scenario. The In-situ Scenario dose is calculated by assuming the inventory of the pipes is in a continuous layer 1 m from the surface, which is not consistent with the expected configuration of the pipes.
Hypothetically placing the inventory in the pipes closer to the surface may be conservative for the external pathway, but it may not be conservative for the groundwater dose. Section 6.12.2.2 of the LTP states that a number of the buried pipes have a very low potential for being contaminated based on their associated systems.
Therefore, the licensee limits the inventory to that within 9.6 m3 of piping in comparison to over 100 m3 of pipe volume that could remain and is listed in Table 2-27 of the LTP.
However, if the total volume of piping in Table 2-27 is expected to remain onsite, then it should be considered in the DCGL calculation.
NUREG 1757 Vol 2 defines DCGLs as Radionuclide-specific concentration limits used by the licensee during decommissioning to achieve the regulatory dose standard that permits the release of the property and termination of the license. The DCGL is the concentration for each radionuclide which would result in doses less than or equal to the release criteria of 25 mrem/yr. It is not clear that the buried pipe DCGLs in Table 6-32 would result in doses less than or equal to 25 mrem/yr should all the pipes in Table 2-27 be left onsite and released according to the DCGLs in Table 6-32.
The licensee seems to confuse the DCGL approach (developing or using DCGLs and performing an FSS to demonstrate that the DCGLs have been met) with the dose assessment approach (characterizing the siteafter remediation, if necessaryand performing a dose assessment) for piping. The licensee should refer to NUREG 1757 Vol. 2, Section 2.5 for guidance related to demonstrating compliance using dose assessment methods versus DCGLs and FSS. The LTP provides DCGLs to be applied for pipes, but Equation 6-5 suggests that a maximum dose from piping will be calculated, which would indicate that the licensee intends to use the dose assessment approach.
Path Forward:
If the licensee desires to follow the DCGL approach using the DCGL values in Table 6-32, provide additional dose modeling calculations showing that if all the piping to remain onsite were released at the DCGL values, the dose to the critical group would be equal to or less than 25 mrem/yr for each radionuclide; If the licensee desires to follow the dose assessment approach, provide reasonable cleaning goals for pipes that can be used in conjunction with the dose assessment approach and a detailed example of how the dose from piping will be calculated during surveys; Provide TSD 14-015, "Buried Pipe Dose Modeling & DCGLs" (Reference 6-4);
Provide TSD 14-021 Basement Fill Model (BFM) Drilling Spoils and Alternate Exposure Scenarios" and associated RESRAD summary files.
- 13. Comment: The use of background in calculating dose for each survey unit to determine whether to analyze for HTD radionuclides should be clarified.
Basis: The LTP (see Section 6.8.2, Section 6.12.1, and Section 5.1) states that if levels of residual radioactivity are encountered in a survey unit for open land, buried piping, or structures that exceeds 10 percent of the 25 mrem/yr Dose Criterion (2.5 mrem/yr), then samples will be analyzed for HTD radionuclides. The LTP does not provide details on how the dose will be calculated and how background radioactivity is treated in the dose calculation (e.g., whether background is subtracted and what that background value is assumed to be for the various survey units).
Path Forward:
Provide an example of how the dose will be calculated to determine whether to test for HTD radionuclides in each type of survey unit or media (e.g., structures, open land, piping). If background is subtracted, provide a technical basis for the background values that will be applied.
- 14. Comment: The methodology that will be used to calculate the compliance dose is not clear.
Basis: Equation 6-5 describes how the compliance dose will calculated from the various source terms at the ZNPS. However, it is not clear how the dose from the source terms will be calculated from the final site FSS data. In particular, it is not clear how the max soil and max buried pipe doses will be calculated from the FSS data and the DCGL values for soil and piping. It is also not clear how the dose from elevated areas will be accounted for in the soil dose.
Path Forward:
Provide additional details regarding the methodology that will be used to calculate the compliance dose, including the equations that will be used to calculate the maximum soil dose and the maximum piping dose from the FSS data.
- 15. Comment: Information on the process for determining the total basement inventory from FSS data is needed.
Basis: In the LTP, the licensee proposes to calculate the dose from the residual radioactivity in the basements from the basement dose factors provided in Table 6-18.
These basement dose factors are used to calculate the dose per total inventory in the each basement. The determination of the total inventory is therefore an important factor in the determination of the projected dose. However, details on how the FSS data will be used to generate a total inventory of residual contamination is not provided in the LTP. The specific equations that will be used to determine the total inventory were not provided. It is not clear how the licensee intends to use individual data points to develop the total inventory. For example, it is not clear how each data point will be factored into the total inventory. Additionally, it is not clear how elevated areas and volumetric contamination will be accounted for. It is also not clear how the inventory will be developed for areas that are below the detection limit.
Path Forward:
Describe how the inventory for each basement will be developed from FSS data, and provide a sample calculation, including the use of any scaling factors; Include a description of how each data point will be factored into the total inventory and the manner in which elevated areas and volumetric contamination will be accounted for; and, Also, describe how the inventory for areas that are below the detection limits will be assessed.
- 16. Comment: Justification is needed for the conceptual model assumed in the basement fill model.
Basis: Many aspects of the conceptual model assumed in the determination of the dose from residual radioactivity in the basements are conservative (e.g., the assumption that the water in the basements can support a well). However, other aspects of the conceptual model may be non-conservative.
The release of the radionuclides is assumed to be either instantaneous for loose surface contamination or a diffusion controlled release for volumetric contamination. The DUST-MS model partitions the released radionuclides between the aqueous and solid phases based on the sorption coefficient (Kd value) for the radionuclide. The Kd approach to modeling the sorption of radionuclides assumes that the medium is a porous medium and that the surface area is available for sorption. It is not clear if this model is appropriate for basements that are backfilled with concrete debris with a diameter of up to 10 inches. The transport of radionuclides in a basement with this configuration may be more like transport through fractures than flow through porous media. In transport through fractures, there may be less sorption, and consequently higher aqueous concentrations, than in transport through a porous medium because less surface area is available for sorption. Tables 11 to 15 in TSD 14-009 show that the model calculated a significant fraction of the radionuclides to be sorbed rather than being in solution for all radionuclides but H-3. The modeling approach assumed in DUST-MS may therefore underestimate the aqueous concentrations in the basements.
Because the conceptual model used in the DUST-MS calculations contains both conservatisms and potential non-conservatisms, the overall conservatism of the basement fill model is not clear.
Path Forward:
Provide a quantitative evaluation that demonstrates that the DUST-MS modeling approach is either appropriate for the expected end state of the backfilled basements or that the DUST-MS modeling approach bounds the potential dose due to the residual radioactivity in the basements.
- 17. Comment: The basis for the parameter values assumed for the mixing volumes and surface areas for the basements is needed.
Basis: Tables 1 and 2 in TSD 14-009 describe the mixing volume and surface area assumed for each building in DUST-MS. An email from Farr was cited as the reference for these volumes, but this reference was not provided as part of the LTP submittal. The NRC staff needs information on the basis for these values to evaluate the DUST-MS modeling results.
Path Forward:
Provide the basis for the mixing volumes and surface areas for the basements assumed in the DUST-MS model; and, Provide the following document: Farr, H.C., Re: New Volumes e-mail September 24, 2014 to T. Sullivan.
- 18. Comment: Additional information is needed on the groundwater and hydrological parameters.
Basis: Section 6.6.1 of the LTP states Based on current demolition plans, there will be no connection between the basements and surrounding groundwater and the End State configuration provides no route for groundwater ingress into the basements, leaving only rainwater infiltration as the source of water in the fill. Section 6.6.1.2 states the projected equilibrium water elevation in the Basements was evaluated in TSD 14-032. The water level is driven by the location, elevation and size of existing penetrations between the Basements and between the Basements and outside ground. In TSD 14-09, it is stated that the mixing volume is calculated assuming that the water level in the basements is equal to the natural water table elevation outside of the basements (i.e.,
579 feet), which is the minimum long term level that could exist in the basements.
Based on these descriptions, it is not clear if there is connectivity between the basements and surrounding groundwater.
Also, TSD 14-032 and TSD 14-006, which contains key hydrological parameters, were not provided to the NRC.
Path Forward:
Describe the connectivity between the basements and surrounding groundwater in the end state configuration; Provide ZionSolutions Technical Support Document 14-032, Conestoga Rovers &
Associates Report, Simulation of the Post-Demolition Saturation of Foundation Fill Using a Foundation Water Flow Model; and, ZionSolutions Technical Support Document 14-006, Conestoga Rovers & Associates (CRA) Report, Evaluation of Hydrological Parameters in Support of Dose Modeling for the Zion Restoration Project.
- 19. Comment: More information is needed on the development of the BFM drilling spoils dose factors.
Basis: Chapter 6 of the LTP describes the drilling spoils dose factor calculations, but the details of this analysis are included in TSD 14-021, which was not provided to the NRC.
From the description in Chapter 6, it is not clear how the source term concentration in the basements with diffusion controlled release was calculated. Section 6.6.7 states The BFM Drilling Spoils scenario addresses one of the BFM exposure pathways listed in section 6.5.4 by calculating the dose from residual radioactivity in fill material (resulting from release from surfaces to clean fill after backfill) which is brought to the surface during the installation of a well in the basement. The activity remaining in the concrete surfaces, if any, is also included in the drilling spoils source term. The text states that the source term for the BFM Drilling Spoils scenario is the average concentration in fill, and remaining in concrete, at the time of maximum groundwater concentration. Later the text states to ensure conservatism and consistency in the BFM source term, the maximum fill concentrations (which occur at the time of maximum groundwater concentrations) are applied for each radionuclide regardless of when the maximum occurs. From these descriptions, it is not clear how the residual contamination remaining in concrete is incorporated into the source term.
Path Forward:
Describe how the residual radioactivity in the concrete is included in the source term for the drilling spoils; and, Provide ZionSolutions Technical Support Document 14-021 Basement Fill Model (BFM)Drilling Spoils and Alternate Exposure Scenarios.
- 20. Comment: Additional details on the basement fill model elevated area consideration are needed.
Basis: In Chapter 6 of the LTP, it is stated that the maximum concentrations that could remain in the Basements are limited by the implementation of the open air demolition limits described in TSD 10-002. These limits include:
less than 2 mR/hr beta-gamma total surface contamination on contact with structural concrete; and, less than 1,000 dpm/100cm2 beta-gamma loose surface contamination.
The loose surface contamination limit is based on the loose surface contamination levels prior to demolition. It is possible that the loose surface contamination levels could increase after demolition due to dust generated during the demolition process.
Also, Chapter 6 of the LTP does not provide sufficient details on how the maximum concentrations assumed in the worst-case drilling spoils scenario were generated.
These details may be in TSD-14-021, which the NRC staff requested in a separate RAI.
Path Forward:
Provide a justification that the loose surface contamination levels will remain within these limits after demolition. Include information on any actions that will be taken to minimize the dust present and any measurements that will be performed to evaluate the final, post-demolition levels of loose surface contamination; and, Provide details on the derivation of the maximum concentration assumed in the worst-case drilling spoils scenario.
- 21. Comment: The basis for assumptions in the sensitivity analysis performed for an outside well receptor is needed.
Basis: In TSD 14-009, a sensitivity analysis was performed for a well receptor located outside of the basements. In this analysis, the peak concentrations in a receptor well 2 m outside the turbine building were calculated. This analysis considered source terms from the auxiliary and turbine buildings with contamination levels of 1 pCi/m2 and 0.001 pCi/m2 respectively. TSD 14-009 states that the well location was selected to be the closest place to put a well outside of the auxiliary building, which is the building that will have the highest levels of residual contamination. It is not clear if sources from other basements, such as the containment building basements, could affect the groundwater at this location. Also, it is not clear how the assumed concentrations will compare to the end state concentrations in those basements.
Path Forward:
Provide a justification for the source terms and concentrations included in the outside well receptor analysis. If the containment buildings, or any other basements, could contribute to the groundwater concentration at the well, provide a sensitivity analysis that estimates the maximum projected groundwater concentration including these source terms; and, Additionally, provide a description of the process that will be used to re-evaluate this analysis if final inventory numbers for the basements are higher than those assumed in this analysis.
References Requested Energy Services Commercial Services Group Report CS-RS-PN-028, Background Reference Area Report - Zion Nuclear Power Station, - February 2012 Farr, H.C., Re: New Volumes e-mail September 24, 2014 to T. Sullivan ZionSolutions Technical Support Document 11-001, "Potential ROC during the Decommissioning of Zion Station" ZionSolutions Technical Support Document 13-004, "Examination of Cs-137 Global Fallout In Soils At Zion Station" ZionSolutions Technical Support Document 14-004, Brookhaven National Laboratory (BNL),
Recommended Values for the Distribution Coefficient (Kd) to be used in Dose Assessments for Decommissioning the Zion Nuclear Power Plant ZionSolutions Technical Support Document 14-006, Conestoga Rovers & Associates (CRA)
Report, Evaluation of Hydrological Parameters in Support of Dose Modeling for the Zion Restoration Project ZionSolutions Technical Support Document 14-011, "Soil Area Factors" ZionSolutions Technical Support Document 14-015, "Buried Pipe Dose Modeling & DCGLs" ZionSolutions Technical Support Document 14-017, Brookhaven National Laboratory (BNL),
Sorption (Kd) Measurements on Cinder Block and Grout in Support of Dose Assessments for Zion Nuclear Station Decommissioning ZionSolutions Technical Support Document 14-019, "ROC for Soil and Basement Fill Model Source Terms" ZionSolutions Technical Support Document 14-020, Brookhaven National Laboratory (BNL),
Sorption (Kd) measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning ZionSolutions Technical Support Document 14-021 Basement Fill Model (BFM) Drilling Spoils and Alternate Exposure Scenarios ZionSolutions Technical Support Document 14-032, Conestoga Rovers & Associates Report, Simulation of the Post-Demolition Saturation of Foundation Fill Using a Foundation Water Flow Model HP Zion RAIs Chapter 2
- 1. Section 2.2.1 (Data Quality Objectives)
Comment: Section 2.2.1 of the LTP indicates that direct measurements and scans of concrete and surface soils were also made using the same instruments and Minimal Detectable Concentrations (MDC) as will be employed for FSS. However, survey methodologies described throughout Chapter 2 of the LTP indicate that alarm set points were utilized during characterization (generally described as being set at the observed background plus the Minimum Detectable Count Rate for the instrument). The calculation of Scan MDCs for FSS in Section 5.8.4.3 of the LTP (Beta-Gamma Scan Measurement MDC) utilizes an equation based on signal detection theory and how a human observer theoretically processes the audible input and then makes decisions. Additional details are needed on the calculation of Scan MDCs used during characterization and the applicability of those MDCs when instrument alarm set points are used.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), licensees should provide:
A description of the field instruments and methods that were used for measuring concentrations and the sensitivities of those instruments and methods.
Section O.3.3.1 (Alarm Set-Points and the MARSSIM Scanning MDC Calculation) of NUREG-1757, Vol. 2, Rev. 1, notes that:
There have been a number of instances where FSS procedures have implemented the use of various detectors coupled to data logging instruments. These instruments in several cases were set to alarm at a pre-determined count rate action level that is calculated to correspond to the DCGLW, rather than relying on the surveyor listening to the audible response. Although this may be an acceptable practice, with the provision of an adequate technical basis, the MARSSIM scan MDC equations are no longer appropriate.
Path Forward:
Provide additional details on the calculation of Scan MDCs for instruments used during characterization; and, evaluate the appropriateness of those MDCs when alarm set points are used.
- 2. Section 2.2.1 (Data Quality Objectives), Section 2.3.4 (Non-Impacted Open Land Areas),
and Section 2.3.5 (Impacted Open Land Areas)
Comment: Section 2.2.1 of the LTP indicates that direct measurements and scans of concrete and surface soils were also made using the same instruments and MDC as will be employed for FSS, and that volumetric samples that exhibited the highest activity were sent to an off-site laboratory for analysis of HTD radionuclide(s). This discussion indicates that HTD radionuclides are only measured during characterization when an elevated direct measurement was encountered, but it is not clear that a surrogate correlation has been established between HTD and easy-to-detect (ETD) radionuclides, or that these radionuclides are co-located at the site. As such, it is not evident that a sufficient number of HTD samples were taken during characterization to establish a surrogate or to adequately characterize the radiological status of the site. For example, Section 2.3.4.1 of the LTP discusses surface soil sampling in non-impacted areas and indicates that of the total number of surface soil samples taken and analyzed, Cs-137 was identified at concentrations greater than the MDC of the instrument in 106 surface soil samples, and that no other potential plant-derived radionuclides were positively identified. However, it is not evident from the discussion in Section 2.3.4.1 and the corresponding results summary in Table 2-29 (Non-Impacted Open Land Survey Units - Characterization Survey Summary) that an analysis of these soil samples was performed for radionuclides other than Cs-137 and Co-
- 60. A similar question exists for the discussion of soil sampling related to Class 2 and 3 impacted areas, as presented in Section 2.3.5 of the LTP and Tables 2-31 and 2-32 (though footnotes associated with Class 3 areas in Table 2-31 indicate that some samples were analyzed for H-3, Fe-55, Ni-63 and Sr-90).
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), licensees should provide:
A description and justification of the survey measurements for impacted media (for example, building surfaces, building volumetric, surface soils, subsurface soils, surface water, ground water, sediments, etc., as appropriate);
The justification for considering areas to be non-impacted; and, A discussion of why the licensee considers the characterization survey to be adequate to demonstrate that it is unlikely that significant quantities of residual radioactivity have gone undetected.
Path Forward:
Describe the basis for only analyzing for HTD radionuclides when an elevated direct measurement was encountered during characterization; Describe the analytical measurements that were performed to ensure potential plant derived radionuclides other than Cs-137 and Co-60 would be positively identified in both non-impacted and impacted areas; and, Provide a justification for considering areas to be non-impacted, when it appears that HTD radionuclides may not have been considered in those areas.
- 3. Section 2.3.1.2. (Crib House Concrete Study)
Comment: Section 2.3.1.2 of the LTP indicates that in March of 2012, ZSRP commenced an assessment of the concrete 594 foot and 559 foot elevation floors and lower walls of the Crib House, and that the Data Quality Objectives (DQO) established for this survey were to establish a background threshold range for volumetric concrete at ZNPS, evaluate the basement foundations and floors of the Crib House for the presence of volumetric radiological contamination and to provide a sufficient quantity and quality of uncontaminated concrete media representative of the Basement Fill concrete to an off-site vendor for the derivation of distribution coefficients for the ROC. Additional clarification is needed on the usage of the Crib House as a background area as Section 2.1.5 of the LTP indicates the Crib House is considered an impacted area, which may not be appropriate for a background area.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A description of the background reference areas and materials, if they will be used, and a justification for their selection.
Path Forward:
Describe the purpose of the background threshold range; and, Clarify if these data are being utilized as background and if so, justify the usage of background data from a radiologically impacted area.
- 4. Section 2.3.3 (Impacted Structures and Systems) and Section 2.3.3.1 (Unit 1 and Unit 2 Containments)
Comment: Section 2.3.3 of the LTP notes that the exposed steel lined walls and floor from the Unit 1 and Unit 2 Containment Buildings (after all interior concrete is removed) and the below-grade structural concrete outside of the liner will remain after demolition and will be subjected to Source Term Surveys. The basic decommissioning end-state for each containment building is further discussed in Section 2.3.3.1, where it is noted that the exposed metal liner will be remediated to levels commensurate with inventory limits in the Basement Fill Model (BFM) that represent the annual dose criterion for unrestricted release specified in 10 CFR 20.1402.
Additional details are needed on characterization of below-grade concrete walls outside of the liner and on steps that may be taken if elevated areas are encountered during remediation.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), licensees should provide:
A description and justification of the survey measurements for impacted media (for example, building surfaces, building volumetric, surface soils, subsurface soils, surface water, ground water, sediments, etc., as appropriate); and, The survey results including tables or charts of the concentrations of residual radioactivity measured.
Path Forward:
Provide details of any current characterization of the below-grade concrete walls outside of the liner and any future characterization plans; and, Describe the steps that will be taken to investigate any elevated areas found during remediation.
- 5. Section 2.3.4.1 (Surface Soils)
Comment: Section 2.3.4.1 of the LTP indicates that approximately 21 percent of the surveyed areas were considered inaccessible, which was defined as an area where personnel or vehicle transit was inhibited by the presence of standing water, marsh or wet-lands, thick underbrush, trees or natural grasses where clearing would be prohibitive.
Clarification is needed on the adequacy of these surveys to demonstrate that it is unlikely that significant quantities of residual radioactivity have gone undetected.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), licensees should provide:
A discussion of why the licensee considers the characterization survey to be adequate to demonstrate that it is unlikely that significant quantities of residual radioactivity have gone undetected; and, A discussion of how they were surveyed or why they did not need to be surveyed for areas and surfaces that were considered to be inaccessible or not readily accessible.
Path Forward:
Provide justification that the samples from accessible areas adequately represent or bound the areas that were inaccessible and why the characterization survey is adequate to demonstrate that it is unlikely that significant quantities of residual radioactivity have gone undetected from these areas.
Chapter 4
- 1. Section 4.4.2 (Analysis for Remediation of Basement Structures (ALARA))
Comment: Section 4.4.2 of the LTP states that in summary, the vast majority of residual radioactivity remaining in the structures after the open air demolition criteria is met and after all concrete is removed from the Containment Building basements will be located in the 542 foot elevation floor of the Auxiliary Building, and that the ALARA assessment for the remediation of basement structures will focus on the 542 foot elevation floor of the Auxiliary Building as this is the location were the greatest benefit of concrete remediation could be achieved. However, previous statements in Section 4.4.2 indicate that the lower 13 foot (~4 m) concrete bottom of the Spent Fuel Pool (SFP) and the Transfer Canal will remain following building demolition, and it is acknowledged that contamination is expected in these areas although characterization has not yet taken place. Clarification is needed on why the 542 concrete is considered to be bounding, and on the plans for additional ALARA analyses.
Basis: As discussed in the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 6 (ALARA Analyses), the information supplied by the licensee should be sufficient to allow NRC staff to fully understand the basis for the licensees conclusion that projected dose limit/residual radioactivity concentrations are ALARA.
Path Forward:
Justify the nature of the 542 foot elevation as a bounding condition for concrete contamination in light of uncharacterized impacted areas elsewhere; and, Describe the plans for any additional ALARA analyses after further characterization is completed.
- 2. Section 4.4.2.1 (ALARA Analysis Equation)
Comment: It is noted in Section 4.4.2.1 of the LTP that for the ALARA analysis for the remediation of basement structures, the equation from section 4.4.1.5 for the ratio of the concentration to the DCGLw when the total cost (CostT) is set equal to the dose averted is modified, and that the denominator must be summed and the individual dose contribution normalized to account for the multiple detectable radionuclides that are present in the radionuclide distribution for the Auxiliary Building. Several points within the calculation are unclear and are discussed as follows:
It appears from the discussion after Equation 4-10 that the final calculation is total cost (CostT) divided by the total benefit of averted dose. However, it is not evident that Equation 4-10 was properly rearranged to perform this calculation; In Equation 4-10, summation to account for multiple ROC is only performed in the denominator, but a decay constant () which would differ for each radionuclide of concern is in the numerator (and would need to be factored into each summation entity);
The label of dose factor in Table 4-3 and the associated reference to Table 4-1 appear to be incorrect. The values actually used in Table 4-3 and Table 4-1 appear to be inventory limits rather than dose factors; It is not clear how the activity fractions in Table 4-3 relate to the fraction of the 25 mrem/year dose limit, and it is similarly not clear how normalization of the activity fraction times the inventory limit (as shown in Table 4-3) relates to the dose limit. The definition of fi shown under Equation 4-10 indicates that fi is the product of the Basement Inventory Levels (BIL) for the Auxiliary Building for each individual Radionuclide of Concern (ROC) (from Chapter 5, Table 5-9) normalized to one, which does not seem to include the activity fraction. The steps in this calculation should be clarified. It would seem appropriate to simply set fi to the respective fraction of the dose limit represented by each radionuclide inventory; As noted in the August 16, 2007 Federal Register notice (72 FR 46102), Consolidated Decommissioning Guidance; Notice of Revision to, Withdrawal of Portions of, and Process for Updating NUREG-1757, the discussion on discount rates was withdrawn.
As such, no discount rate should be used for the analysis, or discount rates could be applied as described in NUREG/BR-0058 (Regulatory Analysis Guidelines of the U.S.
Nuclear Regulatory Commission), which includes a consideration for intergenerational consequences and recommends providing supplemental information and sensitivity/uncertainty analyses whenever the values of key attributes can range widely;
- and, The area (A) of 10000 m2 used to calculate population density is based on the size of the resident farmer reference area. It would be more appropriate to consider the actual footprint of the basement areas being evaluated.
Basis: As discussed in the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 6 (ALARA Analyses), the information supplied by the licensee should be sufficient to allow NRC staff to fully understand the basis for the licensees conclusion that projected dose limit/residual radioactivity concentrations are ALARA.
Path Forward:
Re-evaluate the ALARA analysis presented in Section 4.4.2.1 to ensure that appropriate parameters are used and that there is a clear correlation to the unrestricted use dose limit of 25 mrem/year.
Chapter 5
- 1. Section 5 (Final Radiation Survey Plan)
Comment: Section 5 discusses the beneficial reuse of concrete that meets the non-radiological definition of clean concrete demolition debris and where radiological surveys demonstrate that the concrete is free of plant derived radionuclides above background, and also notes that radiological surveys will be performed in accordance with the guidance of NUREG-1575, Supplement 1, Multi-Agency Radiation Survey and Assessment of Materials and Equipment Manual (MARSAME) (Reference 5-8). Additional clarification is needed on the radiological status of concrete structures which may be reused as fill material and the design of surveys of those materials.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A brief overview describing the FSS design; and, A description of the background reference areas and materials, if they will be used, and a justification for their selection Path Forward:
Provide additional details on the design of surveys that will be performed on reuse concrete, the radiological status of those structures that are candidate for reuse, the determination of background, and the release criteria being used.
- 2. Section 5.1 (ROC and Mixture Fractions), Section 5.7.1.5.2 (Sampling of Subsurface Soils during FSS) and Section 5.7.1.5.3 (Sampling of Subsurface Soils below Structure Basement Foundations)
Comment: Section 5.1 of the LTP states that as currently inaccessible soils, structures and piping systems are made accessible and are surveyed, either by characterization or by Remedial Action Support Survey (RASS), the survey results will be reviewed to ensure that the suite of ROC and radionuclide mixture derived for the Auxiliary Building is applicable.
Section 5.7.1.5.2 of the LTP notes that the HSA as well as the results of the extensive characterization of subsurface soils in the impacted area surrounding the Zion facility have shown that there is minimal residual radioactivity in subsurface soil, and that consequently, Zion proposes to perform minimal subsurface sampling during FSS. However, Chapter 2 of the LTP has also indicated that the assessment of potential subsurface soil contamination is not currently complete, and that the survey of many inaccessible or not readily accessible subsurface soils or surfaces has been deferred. Examples of areas where surveys are deferred were provided as follows: 1) soils under structures; 2) soils under concrete or asphalt coverings; 3) structural wall and floor surfaces in the basements of structures that will remain and be subjected to FRS; 4) the remaining surfaces of the SFP and Transfer Canal after liner removal; 5) the interiors of embedded and/or buried pipe that may remain; and, 6) and the interior and exterior of both Containment domes. Additionally, Section 5.7.1.5.3 of the LTP indicates that, prior to license termination, it will be necessary to ascertain the radiological conditions of sub-slab soils beneath several areas that will remain at the time of license termination (the foundation walls and basement floors below the 588 foot elevation of the Unit 1 Containment, Unit 2 Containment, Auxiliary Building, Turbine Building, Crib House/Forebay, WWTF and remnants of the SFP) to demonstrate suitability for unrestricted release.
Clarification is needed on the manner in which FSS/remediation plans and strategies will be revised in the event that contaminated soils, structures and piping systems are found during additional characterization or FSS sampling activities.
Basis: As discussed under Characterization Surveys in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), the objectives of characterization surveys include:
Determining the nature and extent of residual radioactivity; Evaluating remediation alternatives (e.g., unrestricted use, restricted use, onsite disposal, offsite disposal); and, Developing input to the FSS design.
Path Forward:
Describe how remediation plans/strategies and the FSS design will be revised in the event that contaminated soils, structures and piping systems are found during additional characterization, RASS, or FSS sampling activities.
- 3. Section 5.1 (ROC and Mixture Fractions), Section 5.2.4 (Surrogate Radionuclides),
Comment: As previously discussed in an RAI for Chapter 2, HTD radionuclides were only measured during characterization when an elevated direct measurement was established, and it is not clear that a surrogate correlation had been established between HTD and ETD radionuclides. Similar methodology is presented in Chapter 5 for use during FSS. Without an established surrogate in place NRC staff cannot assess the viability of this relationship and cannot evaluate whether it is an acceptable method to quantify HTD radionuclides during FSS. This relationship is discussed several times in Chapter 5 as follows:
Section 5.1 of the LTP states the concrete samples taken from the underlying concrete of the SFP and Transfer Canal will be analyzed for the presence of (HTD) radionuclides. For other structural surfaces, embedded piping and penetrations included in the BFM, if surveys indicates that the potential dose from residual radioactivity in a structure could exceed 10 percent of the dose limit (2.5 mrem/yr), then the samples will be analyzed for the presence of HTD radionuclides. If surveys indicate the presence of gamma-emitting radionuclides at concentrations greater than 50 percent of a DCGL in soils or buried pipe, then the samples will be analyzed for the presence of HTD radionuclides.
Section 5.2.4 of the LTP states as previously discussed in section 5.1, the radionuclide mixture for Auxiliary Building concrete developed in TSD 14-019 and listed in Table 5-2 are the scaling factors that will be used to determine the surrogate relationship, but further notes that once appropriate scaling factors are determined, the DCGL of the measured radionuclide is modified to account for the represented radionuclide(s) according to the following equation from section 4.3.2 of MARSSIM.
Sections 5.7.1.5.2 and 5.7.1.5.3, which discuss subsurface soil sampling, also indicate that if gamma spectrometry analysis indicates the presence of plant-derived gamma emitting radionuclides at concentrations greater than the DCGLw, then the sample will also be analyzed for the potential presence of HTD ROC.
Additional clarification is needed on the establishment of surrogate relationships at the site to determine the acceptability of proposed sampling strategies.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.2 (Scoping and Characterization Surveys), licensees should provide:
For sites, areas, or buildings with multiple radionuclides, a discussion justifying the ratios of radionuclides that will be assumed in the FSS or an indication that no fixed ratio exists and each radionuclide will be measured separately (note that this information may be developed and refined during decommissioning and licensees may elect to include a plan to develop and justify final radionuclide ratios in the DP).
Path Forward:
Describe the correlation between direct measurement surveys and the presence of HTD radionuclides, and provide adjusted DCGLs that will be used during FSS to account for HTD radionuclides. However, if the licensee intends to develop and refine surrogate ratios during decommissioning a plan to develop and justify final radionuclide ratios should be provided in the LTP, which should include an evaluation of the acceptability of the currently proposed sampling strategies (it may prove useful to consider discussions in MARSSIM Section 4.3.2 on DCGLs and the use of surrogate measurements).
- 4. Section 5.4.3 (Field Screening Methods for RASS of Below-Grade Structural Surfaces):
Comment: Section 5.4.3 of the LTP indicates that, All structural surfaces will be remediated to the open air demolition limits prior to structural demolition. Confirmatory radiological surveys will be performed using approved procedures following remediation and prior to demolition to ensure that contamination levels are acceptable. The radiological surveys will include extensive surveys on the structural surfaces (walls and floors) located below the 588 foot elevation that will remain. These surveys will be performed using conventional gamma instruments in typical scanning and measurement modes. Scanning coverage for pre-remediation surveys on structures prior to open air demolition could include up to 100 percent of the accessible surface area depending on the contamination potential.
Consequently, the pre-remediation surveys performed to prepare building surfaces for open air demolition will provide confidence that structural surfaces that have significant elevated activity will be removed. Once remediation is complete, structural surfaces located above the 588 foot elevation and non-load-bearing interior concrete walls below the 588 foot elevation that contain detectable residual radioactivity will be demolished, reduced in size, packaged and shipped off-site to a licensed disposal facility.
This discussion is provided under the heading of Field Screening Methods for RASS of Below-Grade Structural Surfaces. RASS are intended to demonstrate that remediation is complete (i.e., the dose criterion has been met and areas are ready for FSS). Clarification should be provided on how these surveys meet that goal. It is also not clear how the open air demolition limits relate to the unrestricted release criterion of 25 mrem/yr.
Basis: As discussed under Areas of Review in NUREG-1757, Vol. 2, Rev. 1, Section 4.3 RASS, the purpose of the review of the description of the RASS is to verify that the licensee has designed these surveys appropriately and to assist the licensee in determining when remedial actions have been successful and that the FSS may commence.
Path Forward:
Clarify how the surveys described in Section 5.4.3 of the LTP will assist the licensee in determining when remedial actions have been successful to meet the unrestricted release criterion and that the FSS may commence; and, Provide ZionSolutions Technical Support Document 10-002, Technical Basis for Radiological Limits for Structure/Building Open Air Demolition.
- 5. Section 5.5 (Source Term Survey) and Section 5.5.2.1 (STS Areal Coverage):
Comment: Section 5.5 of the LTP sates that the BFM is a mixing model with a source term based on total inventory that is independent of concentration levels and areal distribution of residual radioactivity, and that the typical scan coverage guidance as presented in MARSSIM, which relies on concentration based DCGLW and DCGLEMC values, is not directly applicable. Section 5.5 further notes that the standard approach in MARSSIM for calculating AFs in conjunction with DCGLW values to determine the acceptability of elevated areas of activity does not apply to the BFM inventory source term which is independent of concentration levels and areal distribution.
Additional discussion in Section 5.5.2.1 notes that, a secondary consideration [of STS areal coverage] is the potential for the presence of small areas of elevated radioactivity in a STS survey unit that could exceed the BIL, and that the areal coverage of the STS should be commensurate with the probability that a small area of elevated radioactivity could exist within a STS survey unit in a concentration exceeding the BIL and the likelihood that such an area would be detected by the STS ISOCS measurements.
The stated threshold for areas of elevated activity is the BIL, which was defined as a maximum activity level for an entire survey unit. This implies that a single elevated area of activity can exceed the total maximum value assumed for the entire survey unit. It is additionally unclear how the BIL is correlated to 25 mrem/year for comparison to the unrestricted release criterion.
Justification should be provided for the usage of the BIL as the threshold value for small areas of elevated radioactivity in the survey design. Clarification should be provided on the treatment of multiple elevated areas in one survey unit.
Basis: As discussed in the Final Status Survey Design described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4, two objectives of the FSS are to:
Demonstrate that the potential dose from residual radioactivity is below the release criterion for each survey unit, and, Demonstrate that the potential dose from small areas of elevated activity is below the release criterion for each survey unit Path Forward:
Describe the correlation of the BIL to a 25 mrem/year release criterion; Provide justification for the usage of the BIL as the threshold value for small areas of elevated radioactivity in the survey design; and, Describe how multiple areas in one survey unit will be accounted for if the threshold value for a single elevated area is the maximum activity level for the entire unit.
- 6. Section 5.5.1 (Instruments Selected for Performing STS)
Comment: Section 5.5.1 of the LTP notes that the Canberra ISOCS has been selected as the primary instrument that will be used to perform STS, and that direct beta measurements taken on the concrete surface will not provide the data necessary to determine the residual radioactivity inventory at depth in concrete and therefore, would have to be augmented with core sampling.
Section 5.5.1 further indicates that the Auxiliary Building 542 foot elevation floor (and possibly the remaining concrete of the SFP/Transfer Canal) is the only structural surface that will remain in the end-state where excessive variability in the geometry of residual radioactivity has been detected at depth, and that concrete core sampling and/or scan surveys may also be used to confirm the areal and depth distribution of activity in concrete in support of ISOCS geometry assumptions and sensitivity analysis.
Additional clarification is needed on the design of core sampling surveys and the methods being utilized to determine the areal and depth distribution of activity in concrete.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A brief overview describing the FSS design; and, A description of scanning instruments, methods, calibration, operational checks, coverage, and sensitivity for each media and radionuclide.
Path Forward:
Describe how surveys will be designed to utilize supplementary core sampling along with ISOCS measurements, including the determination that a representative number of core samples will be taken; and, Justify the usage of scan surveys as a method to confirm the depth distribution of activity in concrete.
- 7. Section 5.5.2 (STS Survey Units)
Comment: Section 5.5.2 of the LTP indicates that, STS will be designed and documented in the same manner as a traditional FSS and performed in accordance with approved procedures and in compliance with FSS quality requirements in the Quality Assurance Project Plan (QAPP). The BFM is not sensitive to the concentration or areal distribution of residual radioactivity. Therefore, there is no intrinsic survey unit size limitation for the basement structures analogous to MARSSIM recommended survey unit sizes, which are based on a building occupancy scenario.
It is indicated that there is no intrinsic survey unit size limitation for basement structures. As such, areas indicated as Class 1 and 2 (as noted in Table 5-10) do not correlate to recommended survey areas from MARSSIM.
Basis: MARSSIM Section 4.6 states that the limitation on survey unit size for Class 1 and Class 2 areas ensures that each area is assigned an adequate number of data points, and that the rationale for selecting a larger survey unit area should be developed using the DQO Process (Section 2.3) and fully documented.
Path Forward:
Describe the rationale for selecting a larger survey unit area and how the DQO process was used for that purpose.
- 8. Section 5.5.2.1 (STS Areal Coverage)
Comment: Section 5.5.2.1 of the LTP notes that, For the purpose of STS design, the Basement Dose Factors were used to calculate a hypothetical maximum inventory level the ROC in each basement as listed in Table 5-9. These calculated values, which are designated as BIL, do not represent the inventory levels expected to remain at license termination. The actual mean inventory determined by performing the STS will be used as the source term in the BFM to determine the dose to the AMCG. As described below, the actual inventory expected to remain in the basements is a small fraction of the BIL.
The BIL is used during STS survey design to determine a reasonable areal coverage based upon the theoretical potential of exceeding the inventory level based upon characterization survey data.
The primary consideration for determining STS areal coverage is the potential for the presence of a residual radioactivity inventory in a STS survey unit that could exceed the BIL.
Survey areal coverage can be a low percentage of the total wall and floor surface area in survey units that have a low potential for exceeding the BIL. Conversely, in areas with a high potential for approaching the BIL, a higher percentage of coverage is justified.
Clarification is needed on the manner in which scanning coverage is determined, and on the consideration of judgmental scans as discussed in MARSSIM Section 2.5.5.
Basis: With regard to scan coverage, MARSSIM Section 2.5.5 (Developing an Integrated Survey Design) discusses the judgmental nature of scans for Class 3 and sometimes Class 2 areas (dependent on the potential for portions of the survey unit to exhibit a higher probability for areas of elevated activity). MARSSIM 2.5.5 states:
The level of scanning effort should be proportional to the potential for finding areas of elevated activity: in Class 2 survey units that have residual radioactivity close to the release criterion a larger portion of the survey unit would be scanned, but for survey units that are closer to background scanning a smaller portion of the survey unit may be appropriate. Class 2 survey units have a lower probability for areas of elevated activity than Class 1 survey units, but some portions of the survey unit may have a higher potential than others. Judgmental scanning surveys would focus on the portions of the survey unit with the highest probability for areas of elevated activity. If the entire survey unit has an equal probability for areas of elevated activity, or the judgmental scans don't cover at least 10 percent of the area, systematic scans along transects of the survey unit or scanning surveys of randomly selected grid blocks are performed.
Class 3 areas have the lowest potential for areas of elevated activity. For this reason, MARSSIM recommends that scanning surveys be performed in areas of highest potential (e.g., comers, ditches, drains) based on professional judgment. This provides a qualitative level of confidence that no areas of elevated activity were missed by the random measurements or that there were no errors made in the classification of the area.
Path Forward:
Describe how the determination of the percentage and location of the areal coverage via ISOCs will consider the need for judgmental measurements in Class 2 and 3 areas.
- 9. Section 5.5.2.2 (STS Sample Size Determination)
Comment: Section 5.5.2.2 of the LTP notes that, Following the guidance in MARSSIM, the Type I decision error that was used for this calculation was set at 0.05 and the Type II decision error was set at 0.05. The upper boundary of the gray region was set at the BFM Inventory Limit. The Lower Bound of the Gray Region (LBGR) was set at the expected fraction of the BFM Inventory Limit in the STS survey unit. The expected fraction of the BIL in both Class 2 STS survey units was set at 50 percent and the expected fraction of the BIL in both Class 3 STS survey units was set at 1 percent. The standard deviation of the concrete core samples taken in the Turbine Building was used for sigma () in the STS survey units for the Turbine Building, Crib House/Forebay, WWTF and Circulating Water Intake and Discharge Tunnels.
It is not clear how the standard deviation of concrete core samples was utilized for the purpose of calculating the relative shift. The upper and lower bounds of the gray region are in terms of total inventory, but there is no description of how the standard deviation of core samples is related to a standard deviation of total inventory or how consistent units are maintained for the purpose of this calculation.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A summary of the statistical tests that will be used to evaluate the survey results, including the elevated measurement comparison, if Class 1 survey units are present; A justification for any test methods not included in MARSSIM; and, The values for the decision errors ( and ) with a justification for values greater than 0.05.
Path Forward:
Clarify the usage of the parameters used to develop the relative shift; and, Describe how the same units and correlation to total inventory are maintained.
- 10. Section 5.5.4 (STS Data Assessment and Application of Results to BFM)
Comment: Section 5.5.4 of the LTP discusses the usage of the Sign Test for STS results as follows:
As described in section 5.10.3.3, the Sign Test will be used to evaluate the remaining residual radioactivity in each survey unit against the dose criterion using the Basement Dose Factors. If the Sign Test fails, the expected fraction of the BIL assumed in survey design as specified in section 5.5.2.1, can be adjusted to higher values that allow the test to pass. This assumes that the total mean inventory in the entire basement, considering all survey units is below 25 mrem/yr. In addition, if a building has multiple STS survey units (e.g. the Auxiliary Building will have three (3)
STS survey units, one for the wall, one for the floor, and one for the embedded piping/penetrations remaining in the Auxiliary Building), the sum of the inventory fractions for each STS survey unit in the building must be less than one. If the sum exceeds one, then an investigation will be performed which may result in the acquisition of additional measurements, the reclassification of the STS survey unit, or additional remediation.
Several points in this discussion require clarification, as discussed below:
It is not clear that the expected fraction of the BIL assumed in survey design was discussed in Section 5.5.2.1.
The implementation of the Sign Test is not fully described, and would benefit from an example calculation. For example the upper bound of the gray region (as discussed in Section 5.2.2) is set to the BIL (which was previously defined as the hypothetical maximum inventory level of the ROC in each basement). The implication is that any sample can include activity up to the hypothetical maximum inventory level of each basement. It does not seem logical to assume every sample can potentially be at the limit if each sample must be added together for a final comparison to that same limit as the survey unit maximum.
The discussion in Section 5.5.4 discusses the fraction of the BIL used in survey design and notes a comparison among inventory fractions, which suggests that the Sign Test may be comparing individual results against a fraction of the BIL.
A DCGL value which would normally be used as the release criterion in the MARSSIM Sign Test, would be correlated to the TEDE to an average member of the critical group that does not exceed 25 mrem/year. As previously noted, there is no description of the dose assessment associated with the BIL, and the correlation to 25 mrem/year.
With regard to the statement that if the Sign Test fails, the expected fraction of the BIL assumed in survey design as specified in section 5.5.2.1, can be adjusted to higher values that allow the test to pass, simply changing design values after a survey unit has failed in order to make the survey unit pass does not seem appropriate. If the licensee intends to use MARSSIM survey methodology, the DQO process should be utilized to determine why a survey unit failed, and consideration should be given to the necessity for additional measurements and re-survey of the survey unit.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A summary of the statistical tests that will be used to evaluate the survey results, including the elevated measurement comparison, if Class 1 survey units are present; A justification for any test methods not included in MARSSIM; and, The values for the decision errors ( and ) with a justification for values greater than 0.05 Path Forward:
Provide additional details on all of the parameters that will be used in survey design and in the Sign Test for STS data assessment; and, Clarify how the BIL (or a fraction of the BIL) will be used in the assessment. A complete example would be useful.
Evaluate whether or not Section 5.5.2.1 was the appropriate reference on the expected fraction of the BIL assumed in survey design.
Clarify what is meant by the statement that if the Sign Test fails, the expected fraction of the BIL assumed in survey design as specified in section 5.5.2.1, can be adjusted to higher values that allow the test to pass, and describe how the DQO process will be utilized to determine why a survey unit failed and to determine the appropriate path forward.
- 11. Section 5.5.5 (Methods for STS of Embedded Piping and Penetrations) and Section 5.7.1.8 (Buried Piping)
Comment: Section 5.5.5 of the LTP discusses surveys of the interior of embedded pipe or penetration sections that cannot be accessed directly, and notes the following:
A static measurement will be acquired at a specified distance traversed into the pipe.
This distance will be determined as a DQO based on the contamination potential in the pipe. The detector output will represent the gamma activity in gross cpm. This gamma measurement value in cpm will then be converted to dpm using an efficiency factor based on the calibration source. The total activity in dpm will adjusted for the assumed total effective surface area commensurate with the pipe diameter, resulting in measurement results in units of dpm/100 cm2.
Buried piping is discussed in Section 5.7.1.8 of the LTP where it is noted that radiological evaluations for piping or drains that cannot be accessed directly will be performed via measurements made at traps and other appropriate access points where the radioactivity levels are deemed to either bound or be representative of the interior surface radioactivity levels providing that the conditions within the balance of the piping can be reasonably inferred based on those data.
Additional clarification is needed on the survey design for embedded and buried piping measurements.
Basis: Per the acceptance criteria described in NUREG-1700, Rev. 1, Section 5 (Final Status Survey Plan), licensees should provide:
Methods for surveying embedded piping.
Challenges related to Embedded and Buried Piping Characterization are also discussed in Appendix O of NUREG-1757, Vol. 2, Rev. 1, where it is concluded that it is incumbent on the licensee to develop and document a comprehensive approach to embedded pipe and buried piping characterization that accounts for limitations and uncertainties, taking into account MARSSIM guidance in developing the related DQOs. Appendix O also notes that, to be found acceptable, the methods should each address the following nine issues:
radionuclides of interest and chosen surrogate; levels and distribution of contamination; internal surface condition of the piping; internal residues and sediments and their radiation attenuation properties; removable and fixed surface contamination; instrument sensitivity and related scan and fixed MDCs; piping geometry and presence of internally inaccessible areas/sections, instrument calibration; and, DQOs.
Path Forward:
Describe the comprehensive approach to embedded and buried piping characterization that accounts for limitations and uncertainties, taking into account MARSSIM guidance in developing the related DQOs. Consideration should be given to the nine issues discussed in Appendix O NUREG-1757, Vol. 2, Rev. 1, and presented in the RAI basis; Describe how a 100 percent surface scan will be performed for Class 1 impacted piping in accordance with MARSSIM; and, Describe how the number of discrete measurements be determined.
- 12. Section 5.6 (Final Status Survey Design)
Comment: Section 5.6 of the LTP discusses FSS design and notes that any minor above-grade structures that will remain on the site (e. g. ISFSI Warehouse, Sewage Lift Station, etc.) will be released for unrestricted use using the survey approach from MARSAME.
Surveys of structures remaining on site may not be within the scope of MARSAME.
Basis: Per MARSAME Section 1.1 (Purpose and Scope of MARSAME) fixed buildings and structures are not considered within the scope of MARSAME. MARSAME Section 1.1 states the following with regard to materials within the scope of MARSAME:
MARSAME provides technical information on approaches for planning, implementing, assessing, and documenting surveys to determine proper disposition of M&E. Release (including clearance) and interdiction are types of disposition options in MARSAME. Detailed descriptions of these disposition options are provided in Chapter 2. Examples of M&E include metals, concrete, tools, equipment, piping, conduit, furniture, and dispersible bulk materials such as trash, rubble, roofing materials, and sludge. Liquids, gases, and solids stored in containers (e.g., drums of liquid, pressurized gas cylinders, containerized soil) are also included in the scope of this document.
MARSAME further indicates the following with regard to the types of materials that are outside the scope of MARSAME:
Radionuclides or radioactivity on workers or members of the public are outside the scope of the document, as are liquid and gaseous effluent releases and real property (e.g., fixed buildings and structures, surface and subsurface soil remaining in place).
Path Forward:
Describe the implementation of MARSAME for minor above-grade structures and justify that such structures are within the scope of MARSAME, or re-evaluate the survey methodology; and, Describe the release criteria to be utilized for structures that will remain.
- 13. Section 5.6.2.5 (Develop a Decision Rule)
Comment: Section 5.6.2.5 of the LTP states that if the SOF is greater than or equal to unity (1), then the survey unit does not meet the criteria for unrestricted release and, further action, including but not limited to additional remediation, survey unit reclassification, additional data collection, or dose assessment will be taken.
It is not clear how a dose assessment will be utilized or how any of the potential actions, other than remediation, would affect an SOF level that is greater than 1.
Basis: As discussed in the Final Status Survey Design described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4, two objectives of the FSS are to:
Demonstrate that the potential dose from residual radioactivity is below the release criterion for each survey unit; and, Demonstrate that the potential dose from small areas of elevated activity is below the release criterion for each survey unit.
Path Forward:
Clarify what is meant by "dose assessment,"; and, Describe how the stated potential actions, other-than remediation, would affect an SOF level greater than 1 in order to demonstrate the survey unit release criterion is met.
- 14. Section 5.6.4.2.1 (WRS Test Sample Size)
Comment: Section 5.6.4.2.1 of the LTP states that Equation 5-1 of NUREG-1507 may alternatively be used to calculate the number of sampling and measurement locations. This is likely a misprint that was intended to refer to Equation 5-1 of NUREG-1575.
Basis: Equation 5-1 in NUREG-1507 deals with total efficiency of a distributed source.
Path Forward:
Correct this statement to refer to the intended reference.
- 15. Section 5.6.4.6 (Investigation Process) and Table 5-13 (Investigation Levels)
Comment: Table 5-13 of the LTP indicates that the direct investigation level for a Class 1 area is a level that is greater than the DCGLEMC. This investigation level does not appear to be consistent with MARSSIM guidance.
Basis: MARSSIM guidance indicates that direct measurements should be flagged for investigation when the DCGLw or a statistical parameter-based value is exceeded (MARSSIM Table 5.8). MARSSIM also notes that For a Class 1 survey unit, measurements above the DCGLw are not necessarily unexpected. However, a measurement above the DCGLw at one of the discrete measurement locations might be considered unusual if it were much higher than all of the other discrete measurements. Thus, any discrete measurement that is both above the DCGLw and above the statistical-based parameter for the measurements should be investigated further. Any measurement, either at a discrete location or from a scan, that is above the DCGLEMC should be flagged for further investigation.
Path Forward:
Describe how an investigation level comparison to the DCGLw and a parameter-based value will be incorporated into the Zion FSS methods, per MARSSIM guidance.
- 16. Sections 5.6.4.6.1 (Remediation and Reclassification)
Comment: Reclassification of survey units is discussed in Section 5.6.4.6.1 of the LTP as follows:
If an individual survey measurement (scan or direct) in a Class 2 survey unit exceeds the DCGLw, the survey unit, or portion of the survey unit, will be investigated, and if necessary, be reclassified to a Class 1 area and the survey re-designed and re-performed accordingly. If an individual survey measurement in a Class 3 survey unit exceeds 50 percent of the DCGLw, the survey unit, or portion of a survey unit, will be investigated, and if determined to exceed the DCGL, reclassified to a Class 1 or a Class 2 survey unit and the survey re-designed and re-performed accordingly. If the elevated survey measurement (>DCGL) is confirmed by investigation, but cannot be thoroughly described as an isolated condition, (i.e., it cannot be demonstrated with great certainty that this condition does not exist elsewhere in the survey unit) the survey unit will be reclassified. If the result cannot be duplicated, the population of the individual and average measurement results with respect to the DCGL will be reviewed, and if the variability does not suggest the initial classification was inappropriate, the survey unit will not be reclassified.
This section describes an allowance for isolated areas of elevated contamination above a DCGL to occur and not result in a reclassification of Class 2 or 3 areas. This is not consistent with MARSSIM guidance.
Basis: MARSSIM discusses reclassification as follows:
(MARSSIM 4.4)
As a survey progresses, re-evaluation of this classification may be necessary based on newly acquired survey data. For example, if contamination is identified in a Class 3 area, an investigation and reevaluation of that area should be performed to determine if the Class 3 area classification is appropriate. Typically, the investigation will result in part or all of the area being reclassified as Class 1 or Class 2. If survey results identify residual contamination in a Class 2 area exceeding the DCGL or suggest that there may be a reasonable potential that contamination is present in excess of the DCGL, an investigation should be initiated to determine if all or part of the area should be reclassified to Class 1.
(MARSSIM 5.5.3.1)
Class 2 Areas. Surface scans are performed over 10 to 100 percent of structure surfaces. Generally, upper wall surfaces and ceilings should receive surface scans over 10 to 50 percent of these areas. Locations of scanning survey results above the investigation level are identified and investigated. If small areas of elevated activity are confirmed by this investigation, all or part of the survey unit should be reclassified as Class I and the survey strategy for that survey unit redesigned accordingly.
Path Forward:
Describe how reclassification will be accomplished in accordance with guidance from MARSSIM Section 4.4 and Section 5.5.3.1.
- 17. Section 5.6.4.6.2 (Re-survey)
Comment: Section 5.6.4.6.2 of the LTP discusses remediation and resurvey during FSS as follows:
If remediation is required in only a small area of a Class 1 survey unit, any replacement measurements or samples required will be made within the remediated area at randomly selected locations following verification that the remediation activities did not affect the remainder of the unit. Re-survey will be required in any area of a survey unit is affected by subsequent remediation activities. Additional guidance regarding the failure and re-survey of a survey unit and is provided in section 8.5.3 of MARSSIM.
Section 8.5.3 of MARSSIM is referred to, but there is no indication of how MARSSIM guidance will be utilized in the event that a small area is remediated in a Class 1 survey unit.
Basis: Section 8.5.3 of MARSSIM discusses the usage of the DQO process and includes examples for Class 1 survey units where the nonparametric statistical tests are both failed and passed.
Path Forward:
Describe how MARSSIM guidance and the DQO process will be implemented if small areas of elevated radioactivity require remediation in Class 1 survey units.
- 18. Section 5.7.1.4.1 (Gamma Scans of Surface Soils)
Comment: Section 5.7.1.4.1 of the LTP indicates that In situ gamma spectroscopy may also be effectively substituted for scanning surveys, and that when this approach is used, the orientation of the detector, FOV, and a priori MDC will be documented and approved as a DQO during FSS design and survey package development.
In situ gamma spectroscopy is also listed in Table 5-14 (Typical FSS Survey Instrumentation) along with text in Section 5.8.1 (Instrument Selection) indicating that Other measurement instruments or techniques may be utilized. The acceptability of additional or alternate instruments or technologies for use in the FSS will be justified in a technical basis evaluation document prior to use. Technical basis evaluations for alternate final status survey instruments or techniques will be provided for NRC review 30 days prior to use.
While in situ gamma spectroscopy is listed in Table 5-14, NRC staff notes that no technical justification for this technology has been provided with regard to scanning of soils.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A description of scanning instruments, methods, calibration, operational checks, coverage, and sensitivity for each media and radionuclide; and, A description of the instruments, calibration, operational checks, sensitivity, and sampling methods for in situ sample measurements, with a demonstration that the instruments and methods have adequate sensitivity Path Forward:
Provide a technical basis for in situ gamma spectroscopy usage for soil scanning, or commit to providing this justification for NRC review 30 days prior to use.
- 19. Section 5.7.1.5. (Subsurface Soils)
Comment: Surveys and sampling of subsurface soils during RASS are discussed in Section 5.7.1.5 of the LTP as follows:
The data obtained during the RASS is expected to provide a high degree of confidence that the excavation, or portion of the excavation, meets the criterion for the unrestricted release of open land survey units. Soil samples will be collected to depths at which there is high confidence that deeper samples will not result in higher concentrations.
Alternatively, a NaI detector or intrinsic germanium detector of sufficient sensitivity to detect residual radioactivity at the DCGLw may be utilized to identify the presence or absence of subsurface contamination, and the extent of such contamination.
It is not clear how a NaI detector or intrinsic germanium detector will be utilized to identify the presence or absence of subsurface contamination, and the extent of such contamination.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A description of scanning instruments, methods, calibration, operational checks, coverage, and sensitivity for each media and radionuclide; and, A description of the instruments, calibration, operational checks, sensitivity, and sampling methods for in situ sample measurements, with a demonstration that the instruments and methods have adequate sensitivity.
Path Forward:
Describe the technical basis for the usage of a NaI detector or intrinsic germanium detector to identify the presence or absence of subsurface contamination at depth and to establish the extent of such contamination.
- 20. Section 5.7.1.6 (Stored Excavated Soils)
Comment: It is noted in Section 5.7.1.6 of the LTP that in several areas, clean overburden soils may be removed and stockpiled on site for use as backfill materials, and that prior to reuse, excavated soil will be surveyed to determine its suitability. It is further noted that scanning requirements and soil sample frequency shall also be determined in accordance with the classification of the area where the soil had originated, and that controls will be instituted to prevent mixing of soils from more restrictive survey area classifications (e.g.,
Class 2 material could be used in either Class 1 or 2 areas and Class 1 material could only be used in Class 1 areas).
Additional details should be provided on the characterization methodology and instrumentation that will be utilized for soils reused from radiologically impacted areas. The NRC staff notes that other licensees have been allowed to reuse excavated soils from impacted areas on site, but only after a demonstration that surveys and characterization of soils are comparable to the rigor of a FSS. This process can be complex, and has generally necessitated the excavation and survey of soils via automated sorting systems or in systematic lifts where the depth of soil is limited to a height that can be adequately scanned.
Basis: Per the acceptance criteria/information to be submitted described in NUREG-1757, Vol. 2, Rev. 1, Section 4.4 (Final Status Survey Design), licensees should provide:
A brief overview describing the FSS design; A description of scanning instruments, methods, calibration, operational checks, coverage, and sensitivity for each media and radionuclide; and, A description of the instruments, calibration, operational checks, sensitivity, and sampling methods for in situ sample measurements, with a demonstration that the instruments and methods have adequate sensitivity Path Forward:
Provide additional details on the methodologies/instrumentation for the reuse of soils from radiologically impacted areas, and demonstrate that surveys will be performed to the rigor of a FSS.
- 21. Section 5.7.1.6 (Stored Excavated Soils)
Comment: Section 5.7.1.6 of the LTP states that soils satisfying the criteria for unconditional release may be stockpiled for use as onsite backfill material. Additional details are needed on the control of cross-contamination when soils are stockpiled for re-use.
Basis: Per the acceptance criteria described in NUREG-1700, Rev. 1, Section 5 (Final Status Survey Plan), licensees should provide:
Access control procedures to control recontamination of clean areas Path Forward:
Describe the administrative and engineering controls that will be maintained to prevent contamination of stockpiled soils from ongoing site remediation activities, or conversely, the contamination of non-impacted areas in the event that impacted soils are stockpiled in a non-impacted area of the site.
- 22. Section 5.10.2.1 (Data Validation)
Comment: In Section 5.10.2.1 of the LTP, one of the data validation actions is to ensure that the instrumentation MDC for fixed or volumetric measurements was below the DCGLw or if not, it was below the DCGLEMC for Class 1, below the DCGLw for Class 2 and below 0.5 DCGLw for Class 3 survey units. This statement is not consistent with MARSSIM, which states that for direct measurements and sample analyses, MDCs (MDCs) less than 10 percent of the DCGL are preferable while MDCs up to 50 percent of the DCGL are acceptable.
Basis: Instrumentation selection is discussed in the MARSSIM Roadmap, where it is noted that for direct measurements and sample analyses, MDCs less than 10 percent of the DCGL are preferable while MDCs up to 50 percent of the DCGL are acceptable.
Path Forward:
Update the review criteria and direct measurement MDCs to be consistent with MARSSIM.
- 23. Section 5.10.5 (Data Conclusions)
Comment: Section 5.10.5 of the LTP indicates that if a data assessment determines that additional samples are necessary to provide sufficient power one course of action might be to determine the number of additional samples and collect them at random locations, and that this method may increase the Type I error, therefore agreement with the regulator will be necessary prior to implementation.
NRC staff concurs that agreement with the regulator will be necessary prior to implementation of a plan to collect additional samples in a failed survey unit. The use of two-stage or double sampling should also be considered as part of the DQO process when developing the design of the FSS.
Basis: NUREG-1757, Vol. 2, Rev. 1, states in Section A.7.5 (Use of Two-Stage or Double Sampling) that the use of two-stage or double sampling should be considered as part of the DQO process when developing the design of the FSS. Further guidance is provided in Appendix C of that volume, which states that:
The term double sampling will be used to refer to the case when the survey design is a one-stage design, but allowance is made for a second set of samples to be taken if the retrospective power of the test using the first set of samples does not meet the design objectives. Such allowance, if given, should be specifically mentioned in preparing the Data Quality Objectives (DQOs) and in advance of any sampling and analysis. During the DQO process, double sampling could be considered as an option in setting the Type I error rates.
Path Forward:
In accordance with NUREG-1757 guidance, describe how the usage of two-stage or double sampling will be considered as part of the DQO process when developing the design of the FSS.
Comment: Section 5.11.2 of the LTP discusses information that will be provided in the FSS and STS final reports. However, there is no description of how ALARA practices were employed to achieve final activity levels.
Basis: NUREG-1757, Vol. 2, Rev. 1 Section 4.5.2 discusses acceptance criteria for final status survey reports and notes that a description of how ALARA practices were employed to achieve final activity levels should be provided.
Path Forward:
Commit to providing a description of how ALARA practices were employed to achieve final activity levels, per NUREG-1757.
Comments on TSD 14-022 (Use of In Situ Gamma Spectroscopy for Source Term Survey of End State Structures)
- 1. Page 5 of 92 Comment: On page 5 of 92, it is mentioned that 100 percent of the surfaces will be measured using ISOCS. Due to the circular field of view (FOV), to truly achieve 100 percent measurement coverage there will have to be some amount of overlap between the FOVs of multiple measurements. Additional details are needed on how overlap between FOVs has been considered.
Basis: Circle packing theorems can be investigated to evaluate whether overlap is necessary. For example, a hexagonal packing arrangement of measurement FOVs will account for 91 percent of the area, with no overlap. This combined with survey data can be inputs to a FOV overlap decision. The amount of overlap (if any) should be determined by the likelihood of missing a high activity spot which falls outside the FOV of neighboring measurements. Data to feed this decision could be derived from survey data.
Path Forward:
Provide additional information as to how the 100 percent measurement requirement will be satisfied, and how the requirement for overlap of FOVs will be determined.
- 2. Page 14 of 92, Table 1 Comment: It was previously stated in the document that the highest level of Cs-137 activity is located within the first one-half inch of concrete. As the core analysis data shows in Table 1, the ratio of activity contained in the first one-half inch to the activity contained in the second half-inch of the core is greater than 3 in all but three core samples.
The three areas which show deep Cs-137 penetration (Samples B105103-CJFCCV-001, B105105-CJFCCV-001, and B105106-CJFCCV-001) exhibit a longer drop-off than the other samples. For these areas the activity at depth may need to be addressed differently than others, as the document mentions in Note 2 on Table 6 on page 26 of 92, and additionally in the conclusion in Section 3.5.
Additional details are needed on the quality assurance (QA) methods to verify the geometry application for areas where activity at depth may need to be addressed differently than others.
Basis: Areas with activity depth profiles that differ from the majority of core samples may have to be treated differently, which is indicated at several points within the document. One of the keys to the measurement campaigns success is ensuring that the correct geometries are applied to the correct areas. If there are going to be specific cases such as the pipe ducts called out, it must be ensured within the program flow that the specific geometries for those areas are applied to the measured spectra.
Path Forward:
Provide details on the QA methods for verifying the geometry application in areas where activity at depth may need to be addressed differently than others.
Environmental Zion RAIs Chapter 8 Basis: Pursuant to 10 CFR 50.82 (a)(9)(ii)(G), the LTP must include a supplement to the environmental report, pursuant to 10 CFR 51.53, describing any new information or significant environmental change associated with the licensees proposed termination activities.
- 1. Section 8.6.3.4 (Water Quality)
Path Forward:
Provide examples of appropriate Best Management Practices (BMPs).
- 2. Section 8.6.3.5 (Air Quality)
Path Forward:
Provide examples of appropriate BMPs; equipment will be maintained to minimize not prevent increased exhaust emissions.
- 3. Section 8.6.3.7 (Terrestrial Ecology)
Path Forward:
Provide specific BMPs.
- 4. Section 8.6.3.11 (Socioeconomic Impacts)
Path Forward:
Provide break out into categories, (e.g., demographics, workforce, housing, public services, and infrastructure).
- 5. Section 8.6.3.13 (Cultural, Historic and Archaeological Resources)
Path Forward:
Provide a copy of the letter from the State of Illinois, Department of Conservation stating that no archaeological, architectural or historic resources are evident on the Zion Nuclear Power Station site.
- 6. Section 8.6.3.15 (Noise)
Path Forward:
Provide a list of equipment types (with manufacturers spec sheets) that will be used on site during demolition and dismantling of facility. Was a pre-construction noise survey conducted?
- 7. Section 8.6.3.16 (Irretrievable Resources)
Path Forward:
Are there any resources that were considered irreversible?
- 8. Section 8.6.3.17 (Traffic and Transportation)
Path Forward:
Provide the number of workers that will be required to dismantle and decommission the facility; Will the on-site parking be adequate for the workers; What roads will workers and haul vehicles use from I-94; How often will waste be shipped to Clive, UT by rail; and, How many rail cars will constitute a shipment?
- 9. Section 8.6.3.18 (Placement of Clean Construction Demolition Debris (CCDD) and Sand Mix in Major Building Basements: Terrestrial Ecology and Transportation)
Path Forward:
How much CCDD and how much sand mix will be required?
How many trucks will be required, and what size trucks will be used?
Where will materials be stockpiled?
What type of equipment will be used to prepare the CCDD?
To what size will it be prepared; to what depth will it be spread? and, Will there be a top soil and vegetation cover?
- 10. Table 8-1 Path Forward:
What document do the sections refer to?
References Requested Environmental Report - Zion Nuclear Power Station Supplement V - May 1972 Final Environmental Impact Statement Related to the Operation of Zion Nuclear Power Station Units 1 and 2 - December 1972 Final Environmental Analysis of Alternatives Regarding Intake/Discharge Structure Deposition at the Former Zion Nuclear Generating Station, Zion, Illinois - October 2013 US Census Bureau - 2008-2012 American Community Survey - 2012 Zion Station Historical Site Assessment - September 2006 Zion Restoration Project Health and Safety Plan, Zion SolutionsZS-SA-01 The City of Zion, Illinois, Comprehensive Plan 2010 - January 1992 Illinois Coastal Management Program, Illinois Beach State Park and North Point Marina Including the Dead River and Kellogg Creek Watersheds - 2011 Additional References Requested Characterization Survey Plan, ZionSolutions ZS-LT-02 Quality Assurance Project Plan (QAPP), ZionSolutions ZS-LT-01 NPDES Permit No. IL0002763, IEPA Characterization of the Zion Station ISFSI. Energy Services Commercial Services Group - July 2012 Annual Report on the Meteorological Monitoring Program at ZNPS for 2010, Murray and Trettel, Inc. - February 2011 Background Reference Area Report, Energy Services Commercial Services Group Report CS-Rs-PN-028 - February 2012 Zion Hydrogeologic Investigation Report, Conestoga Rovers & Associates (CRA), ZionSolutions Technical Support Document 14-003 Zion Environmental Radioactivity Survey, Wisconsin Department of Health Services - 2001
Zion Nuclear Power Station, Units 1 and 2 Service List John Christian President Logistics, Processing and Disposal Group EnergySolutions 1750 Tysons Boulevard, Suite# 1500 McLean, VA 22102 Mr. John Sauger General Manager ZionSolutions, LLC.
101 Shiloh Boulevard Zion, IL 60099-2797 Gerard van Noordennen VP, Regulatory Affairs ZionSolutions, LLC.
101 Shiloh Boulevard Zion, IL 60099-2797 Anthony Orawiec Decommissioning Plant Manager ZionSolutions, LLC.
101 Shiloh Boulevard Zion, IL 60099 Dan Shrum Senior VP, Regulatory Affairs EnergySolutions 423 West 300 South, Suite# 200 Salt Lake City, UT 84101 Russ Workman General Counsel EnergySolutions 423 West 300 South, Suite# 200 Salt Lake City, UT 84101 Alwyn C. Settles Section Head, Nuclear Facilities Inspection Bureau of Nuclear Facility Safety Illinois Emergency Management Agency 1303 N. Milwaukee Avenue Libertyville, IL 60048-1308 Mr. Kent McKenzie Emergency Management Coordinator Lake County Emergency Management Agency 1303 N. Milwaukee Avenue Libertyville, IL 60048-1308 Regional Administrator U.S. NRC, Region III 2443 Warrenville Road Lisle, IL 60532-4352 John E. Matthews Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mayor of Zion Zion, IL 60099 Matias F. Travieso-Diaz Pillsbury Winthrop Shaw Pittman LLP 2300 N Street, NW Washington, DC 20037 Tom Rielly, Executive Principal Vista 360 649 Innsbruck Libertyville, IL 60048 Director Spent Fuel and Decommissioning Strategy Exelon Generation Company, LLC.
4300 Winfield Road Warrenville, IL 60555 J. Bradley Fewell Associate General Counsel Exelon Corporation, LLC.
4300 Winfield Road Warrenville, IL 60555 Document Control Desk - Licensing Exelon Generation Company, LLC.
4300 Winfield Road Warrenville, IL 60555