RIS 2016-04, Clarification of 10 CFR 50.46 Reporting Requirements and Recent Issues Identified with Guidance Not Approved for Use
| ML15324A296 | |
| Person / Time | |
|---|---|
| Issue date: | 04/19/2016 |
| From: | Michael Cheok, Kokajko L Division of Construction Inspection and Operational Programs, Generic Communications Projects Branch |
| To: | |
| Popova A | |
| References | |
| OMB 3150-0011 RIS-16-004 | |
| Download: ML15324A296 (11) | |
OMB Control No.: 3150-0011
ML15324A296 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
OFFICE OF NEW REACTORS
WASHINGTON, DC 20555-0001
April 19, 2016
NRC REGULATORY ISSUE SUMMARY 2016-04 CLARIFICATION OF 10 CFR 50.46 REPORTING REQUIREMENTS AND
RECENT ISSUES WITH RELATED GUIDANCE NOT APPROVED FOR USE
ADDRESSEES
All holders of an operating license or construction permit for a nuclear power reactor under Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities, except those that have permanently ceased operations and have certified that fuel has been permanently removed from the reactor vessel.
All holders of and applicants for a power reactor combined license, standard design approval, or manufacturing license under 10 CFR Part 52, Licenses, Certifications, and Approvals for Nuclear Power Plants. All applicants for a standard design certification, including such applicants after initial issuance of a design certification rule.
INTENT
The U.S. Nuclear Regulatory Commission (NRC) is issuing this regulatory issue summary (RIS)
to clarify the reporting requirements under 10 CFR 50.46, Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors. Specifically, 10 CFR 50.46(a)(3)
requires licensees to report to the NRC each change to, or error discovered in an acceptable emergency core cooling system (ECCS) evaluation model, or in its application, and its estimated effect on the limiting ECCS analysis. This RIS requires no action or written response on the part of an addressee.
BACKGROUND INFORMATION
During recent inspection and review activities, the NRC staff noted that certain licensees made facility changes under 10 CFR 50.59, Changes, tests and experiments, which affected the peak cladding temperature (PCT) calculations for the respective ECCS evaluation models (referred to as evaluation models, for the purposes of this RIS). These licensees did not submit timely reports to the NRC under 10 CFR 50.46(a)(3) regarding the effect of these facility changes on the respective evaluation models. In one instance, installation of a flow orifice changed the high-pressure safety injection system flow rate and resulted in an estimated 309 degree Fahrenheit (°F) increase in the small-break loss of coolant accident (LOCA) PCT. NRC inspectors at the Fort Calhoun site identified1 a non-cited violation of 10 CFR 50.46 in this case because the change was not reported to the NRC within the required 30 day timeframe.
The NRC staff has observed, in the above case and others, that some licensees have relied on third-party guidance documents to determine that certain changes to, or errors in, evaluation models, or the applications of such models, were not reportable under 10 CFR 50.46(a)(3). The NRC has not approved for use or endorsed2 the positions taken in any third-party document providing guidance for compliance with 10 CFR 50.46(a)(3) reporting requirements. The NRC is concerned that, in relying on such guidance, licensees are not providing timely reporting of all changes or errors to evaluation models, or applications thereof, as required under
10 CFR 50.46(a)(3). By not reporting, licensees impact the ability of the NRC to determine the safety significance of each error or change.
In the example above, the NRC inspectors noted that the licensee used a document authored by the Nuclear Energy Institute (NEI), NEI 07-05, 10 CFR 50.46 Reporting Guidelines,3 to make the determination that reporting to the NRC was not required. NEI published NEI 07-05 in July 2008 without formally submitting it to the NRC for review. The NRC staff became aware that licensees were using NEI 07-05 during an inspection activity several years later. The first documented inspection finding that was attributed to use of NEI 07-05 occurred in the case mentioned above at Fort Calhoun in 2014. Specific issues with NEI 07-05 regarding
10 CFR 50.46(a)(3) reporting requirements are discussed in detail in this RIS.
Section 50.46(a)(3) of 10 CFR, which establishes reporting requirements with respect to ECCS
evaluation models, states that each licensee or applicant must:
estimate the effect of any change to or error in an acceptable evaluation model or in the application of such a model to determine if the change or error is significant. For this purpose, a significant change or error is one which results in a calculated peak fuel cladding temperature different by more than 50 °F from the temperature calculated for the limiting transient using the last acceptable model, or is a cumulation of changes and errors such that the sum of the absolute magnitudes of the respective temperature changes is greater than 50 °F.
(ii) For each change to or error discovered in an acceptable evaluation model or in the application of such a model that affects the temperature calculation, the
[licensee/applicant]shall report the nature of the change or error and its estimated effect on the limiting ECCS analysis to the Commission at least annually as specified in § 50.4 or § 52.3 of this chapter, as applicable. If the change or error is significant, the applicant or licensee shall provide this report within 30 days and include with the report a proposed schedule for providing a
1 Hay, Michael, Fort Calhoun - NRC Integrated Inspection Report Number 05000285/2014002 and Notices of Violations, dated March 19, 2014; available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML14078A666.
2 With respect to third-party documents, approved for use means that the NRC has determined that the matters addressed in the document are technically acceptable and consistent with NRC regulatory requirements, guidance and policy, but the NRC neither supports nor discourages entities from using the positions set forth in the document. Endorse, by contrast means that in addition to the NRC determination above, the NRC encourages entities to follow the positions in the document. As a general matter, the NRC rarely endorses third-party documents as NRC guidance.
3 In May 2015, the NRC staff requested NEI 07-05 to be made publically available for purposes of this RIS. NEI
provided an information-only copy in May 2015, which was subsequently made publically available in ADAMS under Accession No. ML15140A631. reanalysis or taking other action as may be needed to show compliance with
§ 50.46 requirements
The evaluation model, as used in 10 CFR 50.46, is defined in 10 CFR 50.46(c)(2) as:
the calculational framework for evaluating the behavior of the reactor system during a postulated loss-of-coolant accident (LOCA). It includes one or more computer programs and all other information necessary for application of the calculational framework to a specific LOCA, such as mathematical models used, assumptions included in the programs, procedure for treating the program input and output information, specification of those portions of analysis not included in computer programs, values of parameters, and all other information necessary to specify the calculational procedure.
The reporting requirements in 10 CFR 50.46(a)(3) were adopted on September 16, 19884 and will be referenced as the 1988 ECCS Rule for the purposes of this RIS. In the statement of considerations (SOC) for the 1988 ECCS Rule, the NRC responded to comments regarding the establishment of a 50°F change in either direction as the threshold for significant5:
The NRC considers a major error or change in any direction a cause for concern because it raises potential questions about the adequacy of the evaluation model as a whole. Therefore, the NRC requires the reporting of significant errors or changes, in either direction, on a timely basis so that the Commission may make a determination of the safety significance
Several comments submitted on the proposed rule leading to the 1988 ECCS Rule questioned the necessity to report minor or inconsequential changes or errors, (i.e., those changes or errors that are not significant) on an annual basis. In the 1988 ECCS Rule SOC, the NRC
responded6:
While errors or changes which result in changes in calculated peak clad temperatures of less than 50 °F are not considered to be of immediate concern, the NRC requires cognizance of such changes or corrections since they constitute a deviation from what previously has been reviewed and accepted
These comment responses from the 1988 ECCS Rule provide a clarification regarding the NRCs intent when establishing reporting requirements. The 1988 ECCS Rule SOC
documented the NRC position that both minor or inconsequential and significant changes need to be reported to the Commission.
SUMMARY OF ISSUE
NRC Staff Position
The requirement in 10 CFR 50.46(a)(3) states that each change to, or error in, an acceptable evaluation model, or in the application thereof, that affects the PCT calculation is reportable. Changes to, or errors in, evaluation models, or in the applications thereof, which
4 53 FR 35996; September 16, 1988
5 53 FR 35998; September 16, 1988
6 53 FR 35998; September 16, 1988 result in significant (i.e., 50 °F or more) changes in the PCT calculation must be reported within
30 days, while those that result in non-significant changes must be reported at least annually.
As discussed above, 10 CFR 50.46(c)(2) defines an evaluation model as the calculational framework for evaluating the behavior of the reactor coolant system during a [LOCA]. In addition, 10 CFR 50.46(c)(2) states that the evaluation model includes all other information necessary for application of the calculational framework to a specific LOCA. Therefore, the NRC considers changes to, or errors in, an evaluation model, or in the application thereof, to include not only changes to, or errors in, the physical models and model parameters that partially comprise the calculational framework (e.g., heat transfer correlations, etc.) but also changes to, or errors in, plant-specific inputs and design parameters (e.g., setpoints, initial conditions, etc.). All of these parameters and inputs are necessary for the analysis of a plant-specific LOCA, as described in 10 CFR 50.46(c)(2).
This NRC staff position has been applied consistently. One example is the NRC response to the public comment from the NEI related to the proposed revision to 10 CFR Part 50, Appendix K, ECCS Evaluation Models, in 2000. The NRC stated, in part7:
10 CFR 50.46(a)[(3)](ii) contains an unambiguous requirement that changes to the ECCS evaluation model must be reported at least annually[O]n the basis of the definition of an evaluation model in § 50.46, the Commission does not accept the distinction made by NEI between model parameters and design parameters.
Additionally, in the SOC for the 1988 ECCS Rule, the NRC addressed a comment discussing the relationship between 10 CFR 50.46(a)(3) and 10 CFR 50.59 requirements with the following explanation8:
One commenter interpreted the use of the words or in the application of such a model as requiring reporting when facility changes (already reportable under
§ 50.59), resulting in model input changes, occur.
The regulatory language referred to is intended to ensure that applications of models to areas not contemplated during initial review of the model do not result in errors by extending a model beyond the range that it was intended. The Commission does not believe that further clarification of this requirement is necessary and has not done so in the final rule.
The NRC declined to change the rule language regarding the requirement to report changes in the application of [an ECCS evaluation] model under 10 CFR 50.46(a)(3), even in consideration of the reporting requirements contained in 10 CFR 50.59. Changes to, or errors in, evaluation models, or in the applications thereof, that affect the PCT calculation and are a result of facility changes made under 10 CFR 50.59, must be reported under 10 CFR 50.46(a)(3). The NRC
maintains that each change to, or error in, an evaluation model, or in the application thereof, that affects the PCT calculation, is reportable under 10 CFR 50.46(a)(3).
7 65 FR 34919; June 1, 2000
8 53 FR 35998; September 16, 1988 Issues Identified Regarding NEI 07-05
The NRC staff identified three specific issues with NEI 07-05 that may lead licensees to inappropriately determine that certain changes to, or errors in, evaluation models, or in applications thereof, are not reportable under 10 CFR 50.46(a)(3). As noted in the abstract for NEI 07-05, the document was not submitted to the NRC for review. Therefore, the discussions in this RIS are not intended to provide a comprehensive discussion of all potential issues associated with NEI 07-05. While this RIS focuses on specific issues with NEI 07-05 as examples, other, similar, third-party guidance documents may have similar issues.
Three of the issues identified in NEI 07-05 are:
A. The definition of the term application in Section 2.2.2 of NEI 07-05, which is inconsistent with the 1988 ECCS Rule SOC.
B. The discussion in Section 2.2.11 of NEI 07-05 that suggests that changes to, or errors in, certain types of inputs to evaluation models, or in the applications thereof, are not reportable under 10 CFR 50.46.
C. The interpretation of the relationship between requirements under 10 CFR 50.46 and
10 CFR 50.59 in NEI 07-05.
Each of these issues is addressed in further detail below.
A. The Definition of Application
Although neither 10 CFR 50.2, Definitions, nor 10 CFR 50.46 define the word application, the NRC has consistently applied a broad, plain-language definition of this term, considering the application of an evaluation model to mean the act of putting an evaluation model to use. The NEI 07-05 definition of application is narrower than the NRCs interpretation, and NEI 07-05 states that it is consistent with certain passages in the 1988 ECCS Rule SOCs.
While the NEI 07-05 definition of application may appear consistent with certain portions of the NRCs comment response in the 1988 ECCS Rule SOC, it is inconsistent with the general discussion on the reporting requirements in the 1988 ECCS Rule SOC. For example, the 1988 ECCS Rule SOC stated that the NRC requires cognizance of both significant and non- significant changes, since they constitute a deviation from what has previously been reviewed and accepted. Rather than to define the word application, the purpose of the 1988 ECCS
Rule SOC statement regarding the application of the evaluation model, discussed in the NRC
Staff Position section, was to respond to a public comment suggesting that the language, or in the application of an evaluation model, was unnecessary due to the 10 CFR 50.59 reporting requirements that existed at the time. The NRC chose to retain the phrase in the rule language and indicated in the 1988 ECCS Rule SOC that further clarification was not needed.
In summary, the NRCs definition of the term application ensures that changes to, or errors in, evaluation models, or in the applications thereof, that affect the PCT calculation, are reported to the NRC. Narrower definitions of the term application, as found in NEI 07-05, can lead licensees to erroneously exclude from reporting under 10 CFR 50.46(a)(3) certain changes to, or errors in, evaluation models, or in the applications thereof. By not reporting to the NRC as required under 10 CFR 50.46(a)(3), licensees impact the ability of the NRC to determine the safety significance of each error or change. Such unreported changes or errors may be inconsistent with the NRCs prior safety review and approval. B. Discussion and Reportability of Input Information
Although neither 10 CFR 50.2 nor 10 CFR 50.46 define the phrase input information, such information may include component lengths and volumes, initial temperatures and pressures, safety injection flows, set points, cycle specific physics parameters, and fuel design parameters, as discussed in Section 2.1.11 of NEI 07-05. Nevertheless, the distinction between input information and other aspects of an evaluation model does not impact the determination of reportability under 10 CFR 50.46(a)(3). The following discussion provides some additional consideration regarding the NRC staff position concerning the treatment of input information in the context of 10 CFR 50.46(a)(3) requirements.
As discussed in the NRC Staff Position, each change to, or error in, an acceptable evaluation model, or in the application thereof, that affects the PCT calculation, is reportable, including changes to, or errors in, plant-specific inputs that may have resulted from facility changes. Furthermore, an evaluation model, as defined in 10 CFR 50.46(c)(2), includes, all other information necessary for application of the calculational framework to a specific LOCA. Specifically, 10 CFR 50.46(c)(2) defines the information necessary for the application of the calculational framework to include such information as:
mathematical models used;
assumptions included in the programs;
procedure for treating the program input and output information;
specification of those portions of analysis not included in computer programs;
values of parameters; and
all other information necessary to specify the calculational procedure.
As mentioned above, NEI 07-05 states that input information includes component lengths and volumes, initial temperatures and pressures, safety injection flows, set points, cycle specific physics parameters, and fuel design parameters. Although the guidance provided in NEI 07-05 suggests that certain changes to, or errors in, these quantities would not be reportable under
10 CFR 50.46(a)(3), these types of changes and errors fall within two categories specifically included in the definition of evaluation model provided in 10 CFR 50.46(c)(2). For example, component lengths and volumes constitute information necessary for application of the calculational framework to a specific LOCA. While components are included in computer codes, their specific dimensions, which vary from plant to plant, must be specified in the analysis. In addition, cycle specific physics parameters and fuel design parameters are both values of parameters, as are initial temperatures and pressures, safety injection flows and set points. Since this information is included in the 10 CFR 50.46(c)(2) definition of evaluation model, changes to, or errors in, this information, which affect the PCT calculation, must be reported in accordance with 10 CFR 50.46(a)(3).
The NRC recognizes that there may be some overlap between the information identified as part of an evaluation model, as defined in 10 CFR 50.46(c)(2), and the information that would be considered part of the application of an evaluation model. Two examples are discussed below.
First, some plant- and cycle-specific core design parameters, such as peaking factors, are included in the definition of evaluation model, but are also part of the plant-specific application of the evaluation model. This first example indicates some overlap between the evaluation model and its application. Second, some best-estimate evaluation models that rely on random sampling to perform adjustments to values of parameters, such as correlation coefficients, use a multiplier that varies randomly from case-to-case. The nominal value of the parameter and the sampling range or probability density function from which the parametric multiplier is determined would generally be considered part of the evaluation model, but the specific value that is used in a particular case would be considered part of the application of the evaluation model. In this second example, there is a distinction between information that belongs to the evaluation model, and information that is considered part of the application of the evaluation model.
Changes to any of the parameters identified in the two examples above that affect the PCT
calculation would be considered reportable. Changes to the core design parameters, the nominal values of correlation coefficients, or the probability density functions for correlation coefficients would be reportable as changes to the evaluation model. Changes to core design parameters, or a specific value of a correlation coefficient used as part of a plant-specific analysis would be considered reportable as changes to the application of an evaluation model. However, because the reporting requirements are the same for either type of change, neither the specific distinction, nor the occurrence of overlap between the two, is important.
The NRC position, that plant input changes are considered changes to the evaluation model and are reportable under 10 CFR 50.46, is a long-standing position that the NRC has previously stated. In 1999, NEI offered a definition of input information in the context of
10 CFR 50.46(a)(3), similar to the NEI 07-05 discussion that is described above, in a letter9 to the NRC. In the letter, NEI suggested that the NRC add language in the Federal Register stating that, [c]hanges resulting from plant specific design parameter changes, including cycle-to-cycle reload fuel parameters, are not reportable under 10 CFR 50.46(a)(3). The NRC
responded to the letter in 2000 stating, in part, that the Commission does not agree with NEI
on this point... 10 CFR 50.46(a)[(3)](ii) contains an unambiguous requirement that changes to the evaluation model must be reported at least annually
In summary, the NRCs interpretation of the reportability of input information ensures that changes to, or errors in, evaluation models or applications thereof, which affect the PCT
calculation, are reported to the NRC. Licensees who adopt the view that plant-specific input information is not reportable, as described in NEI 07-05, may erroneously exclude certain changes to, or errors in, evaluation models or applications thereof from reporting under
10 CFR 50.46(a)(3). By not reporting to the NRC, licensees impact the ability of the NRC to determine the safety significance of each error or change, which may be inconsistent with the NRCs prior safety review and approval.
C. The Interpretation of the Relationship Between 10 CFR 50.46 and 10 CFR 50.59
Several sections of NEI 07-05, among other third-party guidance documents, interpret the relationship between 10 CFR 50.46 and 10 CFR 50.59. The NRC has endorsed only one guidance document, NEI 96-07, Guidelines for 10 CFR 50.59 Implementation,10 regarding
9 Modeen, David J., Nuclear Energy Institute, letter to U.S. Nuclear Regulatory Commission, Transmittal of Comments on Proposed Change to 10 CFR 50, Emergency Core Cooling System Evaluation Models
(64 Fed. Reg. 53270) Request for Comments, Project Number 689, December 15, 1999. Available in ADAMS at Accession No. ML003671779.
10 Available in ADAMS at Accession No. ML003771157. The NRC endorsed NEI 96-07 through Regulatory Guide (RG) 1.187, Guidance for Implementation of 10 CFR 50.59, Changes, Tests, and Experiments, dated November
2000; RG 1.187 is available publically for download at http://www.nrc.gov/reading-rm/doc-collections/reg- guides/power-reactors/rg/. 10 CFR 50.59. The discussion below provides some consideration regarding the relationship between the requirements of 10 CFR 50.46 and 10 CFR 50.59.
Regarding the applicability of 10 CFR 50.46(a)(3) reporting requirements, the NRC stated, in the
1988 ECCS Rule SOC, that the NRC requires cognizance of all changes or errors. The NRC
did not distinguish between changes to, or errors in, an evaluation model, or in the application of such a model, when discussing the need for licensees to report significant as well as minor changes or errors. The NRC also stated in the 1988 ECCS Rule SOC that by not providing timely reporting of all changes to, or errors in, evaluation models, or in the applications thereof, which result in changes to the PCT calculation of more than 50°F, licensees impact the ability of the NRC to determine the safety significance of each error or change. These considerations also apply to changes or error corrections to an evaluation model, or its application, that reflect facility changes accomplished in accordance with 10 CFR 50.59.
Based on the nature and the effect of a particular change to an evaluation model, both
10 CFR 50.46 and 10 CFR 50.59 should be independently applied on their own merits. Specifically, 10 CFR 50.59(c)(4) states:
The provisions in this section do not apply to changes to the facility or procedures when the applicable regulations establish more specific criteria for accomplishing such changes.
Since 10 CFR 50.46 establishes more specific criteria for estimating the effects of and reporting changes to, or errors in, evaluation models, or in the applications thereof, 10 CFR 50.59 reporting requirements do not apply to changes made to evaluation models. Note, however, that facility changes must be screened and evaluated according to 10 CFR 50.59 criteria, while associated changes to, or errors in, the evaluation model, or in applications thereof, that affect the PCT calculation, are subject to 10 CFR 50.46 reporting requirements.
Passages within NEI 07-05 suggest that changes made under 10 CFR 50.59 may not be reportable under 10 CFR 50.46(a)(3). As published, this guidance can lead to an interpretation of the relationship between 10 CFR 50.46 and 10 CFR 50.59 that is inconsistent with the reporting requirements of both rules. Reporting to the NRC enables the NRC to determine the safety significance of each change to, or error in, an evaluation model, or in its application.
CONCLUSION
If a change is made to an evaluation model, or the application thereof, 10 CFR 50.46(a)(3)(i)
requires licensees to estimate the effect of the change on the PCT calculation for the limiting transient. If the estimated change to the calculated PCT is significant (i.e., different by more than 50°F), then the licensee is required to submit a report to the NRC describing the nature of the change and its estimated effect on the limiting ECCS analysis within 30 days. If the estimated change to the PCT is not significant, then the licensee is required to include such a change in an annual report to the NRC as required by regulations in 10 CFR 50.46. Reporting this information to the NRC enables the NRC to determine the safety significance of each error or change to an evaluation model or its application.
An evaluation model is defined in 10 CFR 50.46(c)(2) as the calculational framework for evaluating the behavior of the reactor coolant system during a [LOCA] and includes all other information necessary for application of the calculational framework to a specific LOCA. Based on the evaluation model definition provided in 10 CFR 50.46(c)(2), the NRC considers changes to, or errors in, evaluation models, or in the applications thereof, to include not only changes to, or errors in, the physical models and model parameters that partially comprise the calculational framework but also changes to, or errors in, plant-specific inputs and design parameters.
The process under 10 CFR 50.46 for making changes to an evaluation model (or its application)
and reporting such changes is separate from the process in 10 CFR 50.59 for making changes to a facility as described in the final safety analysis report (as updated). Based on the nature and the effect of a particular change to an evaluation model, both 10 CFR 50.46 and
10 CFR 50.59 should be independently applied on their own merits.
As discussed above, the guidance provided in NEI 07-05 may lead licensees to inappropriately determine that certain changes to, or errors in, evaluation models, or in applications thereof, are not reportable under 10 CFR 50.46(a)(3). Licensees that rely on third-party guidance documents, such as NEI 07-05, which the NRC has neither approved for use, nor endorsed, do so at their own risk.
BACKFITTING AND ISSUE FINALITY DISCUSSION
This RIS discusses reporting requirements under 10 CFR 50.46 applicable to operating license holders (including combined license holders) with respect to ECCS analyses and modeling.
This RIS does not set forth any new or changed NRC requirement, or new or changed guidance or position on compliance with any existing NRC regulatory requirement. The RIS does not require any action by any addressee, nor does this RIS request or suggest that any addressee submit information to the NRC, which is not already required to be submitted by existing NRC
requirements under 10 CFR 50.46 or any other NRC regulation (e.g., 10 CFR Part 21). For these reasons, this RIS does not represent backfitting as defined in 10 CFR 50.109(a)(1) and is not otherwise inconsistent with any issue finality provision in 10 CFR Part 52. Therefore, the NRC did not prepare a backfit analysis for this RIS or further address the issue finality criteria in
10 CFR Part 52.
FEDERAL REGISTER NOTIFICATION
The NRC published a notice of opportunity for public comment on this RIS in the Federal Register (80 FR 44160) on July 24, 2015. The NRC staff received comments from nine commenters. The NRC staff considered all comments, which resulted in minor clarifications to the RIS. The evaluation of these comments, and the resulting changes to the RIS are discussed in a publicly available memorandum.11
CONGRESSIONAL REVIEW ACT
The NRC has determined that this RIS is not a rule as designated by the Congressional Review Act (5 U.S.C. §§ 801-808) and, therefore, is not subject to the Act.
11 Available in ADAMS under Accession No. ML15271A055.
PAPERWORK REDUCTION ACT STATEMENT
This RIS does not contain new or amended information collection requirements that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing requirements were approved by the Office of Management and Budget, approval number 3150-0011.
Public Protection Notification
The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information or an information collection requirement unless the requesting document displays a currently valid OMB control number.
CONTACT
Please direct any questions about this matter to the technical contacts listed below.
/RA/
/RA/
Michael C. Cheok, Director
Lawrence E. Kokajko, Director Division of Construction Inspection
Division of Policy and Rulemaking and Operational Programs
Office of Nuclear Reactor Regulation Office of New Reactors
Technical Contacts: Benjamin T. Parks, NRR/DSS/SNPB
301-415-0979
E-mail: Benjamin.Parks@nrc.gov
Reed A. Anzalone, NRR/DSS/SNPB
301-415-2988
E-mail: Reed.Anzalone@nrc.gov
Jennifer M. Whitman, NRR/DSS/SRXB
301-415-3253
E-mail: Jennifer.Whitman@nrc.gov
Project Manager:
Alexandra E. Popova, NRR/DPR/PGCB
301-415-2876
E-mail: Alexandra.Popova@nrc.gov
- via e-mail
TAC MF5565 OFFICE
NRR/DSS/SNPB* NRR/DSS/SRXB* NRO/DSRA/SRSB*
NRR/DORL*
NRR/DSS*
NRO/DSRA*
NRO/DCIP
NAME
JDean EOesterle (A)
RKaras (A)
GWilson RTaylor JMonninger MCheok DATE
03/16/2016
03/17/2016
01/15/2016
04/14/2015
04/15/2015
04/02/2015
04/17/2015 OFFICE
OE/EB*
NRR/PMDA*
OIS*
NRR/DPR/PGCB
OGC*
NRR/DPR/PGCB
NRR/DPR/PGCB*
NAME
GFigueroa LHill TDonnell ELee GMizuno ELee APopova DATE
03/25/2015
03/20/2015
04/02/2015
01/21/2016
03/18/2016
04/05/2016
04/05/2016 OFFICE
NRR/DPR/PGCB*
NRO/DCIP
NRR/DPR
NRR/DPR
NAME
SStuchell MCheok AMohseni LKokajko
DATE
03/31/2016
4/7/16
4/18/16
4/19/16