Browns Ferry Nuclear Plant Extended Power Uprate License Amendment Request Probabilistic Risk Assessment Gerry Doyle Director EPU May 21, 2015
BFN EPU - Agenda Browns Ferry EPU License Amendment Request PRA
Introductions
OverviewandSchedule BrownsFerryNuclearPlantProbabilisticRiskAssessment (PRA)
Questions/Comments G.Doyle G.Doyle D.Kearnaghan G.Doyle l 2
BFN EPU - Overview and Schedule Browns Ferry EPU License Amendment Request PRA
- New consolidated Browns Ferry Nuclear Plant (BFN)
Extended Power Uprate (EPU) License Amendment Request (LAR) submittal SupersedespreviousBFNEPUsubmittals AddressescurrentBFNconditionsandlicensingbasis(e.g.,AREVA ATRIUM10XMfueltype)
UsestheformatofRS001,ReviewStandardforExtendedPower Uprates AddressespreviousapplicableNRCRequestsforAdditional Information(RAIs)
Appliesimprovedsubmittalverificationprocesstoensure completenessandaccuracy l 3
BFN EPU - Overview and Schedule Browns Ferry EPU License Amendment Request PRA l 4
BFN EPU - Overview and Schedule Browns Ferry EPU License Amendment Request PRA Weareheretopresentanddiscussourapproachtodeveloping thePRAportionoftheBFNEPULAR
- ThecurrentBFNPRAmodelsweredevelopedassumingEPU conditions TodeterminethedeltaCoreDamageFrequency(CDF)anddelta LargeEarlyReleaseFrequency(LERF)valuesfortheBFNEPULAR, changestotheexistingPRAmodelswerenecessary Thepurposeofthismeetingistodiscusstheapproachusedfor changingtheexistingPRAmodelstoallowcalculationoftheCurrent LicensedThermalPower(CLTP)CDFandLERFvalues l 5
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA
Background
- BFNispursuingapoweruprate CLTP3458MWth EPU3952MWth
- ConstantPressurePowerUprate 1050psia SteamDomePressure
- MaximumExtendedLoadLineLimitAnalyses power/flowmapisretained
- Feedwater andSteamFlowIncreased l 6
Background(continued)
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA l 7
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA ScopeofRiskEvaluation
- AtPowerRisk
- InternalEvents Transients LossofCoolantAccidents(LOCAs)
AnticipatedTransientswithoutScram(ATWS)
- InternalFlooding
- InternalFires
- SeismicEvents
- OtherExternalEvents
- ShutdownRisk l 8
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA Methodologies
- QuantitativeMethodologies InternalEvents InternalFires CDFandLERFcalculatedforEPUandCLTPconditions Deltariskcalculated
- QualitativeMethodologies SeismicEvents OtherExternalEvents ShutdownRisk CDFandLERFestimatedusingconservativemethods l 9
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA QuantitativeRiskEvaluationProcess InternalEventsandFiresOnly
- DefinePRAscopeforEPUandCLTP
- ReviewEPUchangesforPRAImpact Physicalmodifications Procedurechanges Setpoint adjustments Plantoperatingconditions
- IdentifyPRAmodelelementsimpacted
- EvaluateEPUandCLTPthermalhydraulics
- Revisemodelsasnecessary
- Quantifyresults l 10
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA InternalEventsModel
- EPUModel ConsideredEPUmodificationsscheduledforimplementationpostEPU Licenseissuance ThermalHydraulic(T/H)Analysisperformedat120%OriginalLicensed ThermalPower(OLTP)(MAAP4.0.7)
Operatoractiontimesareshorterduetohigherdecayheat Increasedprobabilityofstuckopenreliefvalvesassumed Higherhumanerrorprobabilities IncreaseddependenciesforHumanErrorProbabilities(HEPs)
NoneoftheEPUmodificationsresultedinaPRAlogicmodelchange
- CLTPModel IncludedEPUmodificationsimplementedpriortoEPULicenseissuance UsedcurrentBFNPRAModelofRecordasbasis T/HAnalysisperformedat105%OLTP(MAAP4.0.7)
Increasedallowableoperatoractiontimes l 11
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA FirePRAModel
- DevelopedtosupportNationalFireProtection Association(NFPA)805Transition
- EPUModel CreditsEmergencyHighPressureMakeupPumpandotherFireRisk Modifications T/HAnalysisperformedat120%OLTP(MAAP4.0.7)
Operatoractiontimesareshorterduetohigherdecayheat Increasedprobabilityofstuckopenreliefvalvesassumed Higherhumanerrorprobabilities NoneoftheEPUmodificationsresultedinaPRAlogicmodelchange
- CLTPmodel CreditsEmergencyHighPressureMakeupPumpandotherFireRisk Modifications IncludedEPUmodificationsimplementedpriortoEPULicenseissuance T/HAnalysisperformedat105%OLTP(MAAP4.0.7)
Increasedoperatoractiontimeswithlessdecayheat l 12
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA QualitativeRiskEvaluationProcess
- SeismicandOtherExternalEvents ReviewexistingIndividualPlantExaminationsforExternal Events(IPEEEs)
DetermineEPUimpactoninitiators Determineifnewvulnerabilitiesexist AssessriskforCLTPandEPUconditions
- ShutdownRisk Initiatingevents Successcriteria TimetoBoil TimetoCoreUncovery Humanreliability AssessriskforCLTPandEPUconditions l 13
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA AggregationofRisk
- SummedindividualcontributionsofCDFand summedindividualcontributionsofLERF QuantifiedInternalEventsandFireValues DevelopedestimatesforSeismicandExternalEvents l 14
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA PRAQuality
- PRAModelshavebeenpeerreviewed ASME/ANSRASa2009PRAStandardasendorsedbyRevision2of RegulatoryGuide(RG)1.200,AnApproachforDeterminingtheTechnical AdequacyofPRAResultsforRiskInformedActivities Part2forInternalEvents-Peerreviewconductedin2009 Additionalfocusedscopepeerreviewofinternaleventsplannedfor2015 Part4forFirePRA-Peerreviewconductedin2012 AdditionalfocusedscopepeerreviewoffireeventsconductedMay2015
- Applicationofmodelsconsistentwith:
RS001,ReviewStandardforExtendedPowerUprates NUREG0800,StandardReviewPlan,Chapter19.2,AppendixD,Useof RiskInformationinReviewofNonriskinformedLicenseAmendments
- Evaluationofchangeinriskconsistentwith:
RG1.174,AnApproachforUsingPRAinRiskInformedDecisionsonPlant SpecificChangestotheLicensingBasis l 15
Facts and Observations Browns Ferry EPU License Amendment Request PRA FactsandObservations(F&Os)
- F&Osweregeneratedduringpriorpeerreviews AllF&Osdispositioned NoF&OsimpacttheEPUconclusions CapabilityCategoryIIismetwithdispositionoftheF&Os
- FocusedscopepeerreviewstocloseF&Os ExpecttosubstantiallyreducethenumberofF&Os l 16
Total Risk Results CDF LERF Frequencies are units of per reactor-year
==
Conclusion:==
The change in CDF and LERF for BFN Units 1, 2, and 3 due to transitioning to EPU power results in a small and acceptable increase in risk (i.e., RG 1.174, Region II of Figures 4 and 5)
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA l 17
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA KeyRiskInsights
- SmallchangeinriskduetoEPUtransition Changeinriskdrivenprimarilybyfiresequences
- Factorsinriskincrease Increaseddecayheat Shortenedtimeforimportantoperatoractions
- Dominantsequences(InternalEventsandFires)
Involvelossofinventorymakeupinwhichthereactor pressureremainshigh ImportantOperatorActions Manualcontrolofreactorlevelwithhighpressuresystems Manualdepressurizationofreactorvessel l 18
Key Risk Insights (continued)
- Seismic risk Minimal EPU impact on seismic risk External eventno impact on seismic initiating event frequency Proposed EPU modifications qualitatively reviewed to verify no seismic risk impact
- Shutdown risk Minimal EPU impact on shutdown risk Decay heat is highershorter times to boil and uncover core However, system time windows to perform operator actions are long (hours)
- Other external events (high winds, tornados, transportation, etc.)
Minimal EPU impact on external event risk BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA l 19
SensitivityAnalyses
- InternalEventsPRA IncreasedFailureProbabilities ScreeningHEPs RPVoverpressureprobability IncreasedInitiatingEventFrequencies GeneralTransients LOCAs
- FirePRA IncreasedHEPs IncreasedFrequencyofLubeOilFireScenarios Conservativefireseverityfactorswereusedfor:
Condensatepumps Condensateboosterpumps Feedwater pumps
- Conservativesensitivitycasesdidnotresultinchangestorisk conclusions RG1.174CDF/LERFAcceptanceCriteriamet(RegionII)
BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA l 20
Conclusions
- BFNPRAmodelsaretechnicallyadequateforthisnon riskinformedEPUapplication
- EPUimpactonBFNCDFandLERFissmallandwithin RegionIIofRG1.174AcceptanceGuidelines
- Basedonsmallriskimpact,EPUdoesnotcreatespecial circumstancesthatchallengethepresumptionof adequateprotectiontothehealthandsafetyofthe public BFN EPU - PRA Browns Ferry EPU License Amendment Request PRA l 21
BFN EPU - Acronyms Browns Ferry EPU License Amendment Request PRA l 22 LOCAs - Loss of Coolant Accidents Mlbm/hr - Million pounds mass per hour MWth - Megawatts thermal NFPA - National Fire Protection Association OLTP - Original Licensed Thermal Power psia - pounds per square inch absolute PRA - Probabilistic Risk Assessment RAIs - Requests for Additional Information RG - Regulatory Guide T/H - Thermal Hydraulic ANS - American Nuclear Society ASME - American Society of Mechanical Engineers ATWS - Anticipated Transients Without Scram BFN - Browns Ferry Nuclear Plant CDF - Core Damage Frequency CLTP - Current Licensed Thermal Power EPU - Extended Power Uprate F - Farenheit F&Os - Facts and Observations HEPs - Human Error Probabilities IPEEEs - Individual Plant Examinations for External Events LAR - License Amendment Request LERF - Large Early Release Frequency
BFN EPU - Questions/Comments Browns Ferry EPU License Amendment Request PRA l 23