6/9/2015, Meeting Slide for Browns Ferry Nuclear Plant Regarding Extended Power Uprate License Amendment Request Flow Induced Vibration Monitoring Program
ML15147A057
Person / Time
Site: Browns Ferry  
Issue date: 06/09/2015
From: Doyle G
Tennessee Valley Authority
To:
Plant Licensing Branch II
Buckberg P, NRR/DORL/LPL2-2 301-415-1383
References
Download: ML15147A057 (17)


Text

Browns Ferry Nuclear Plant Extended Power Uprate License Amendment Request Flow Induced Vibration Monitoring Program Gerry Doyle Director EPU June 9, 2015

BFN EPU - Agenda Browns Ferry EPU License Amendment Request FIV Monitoring Program

Introductions

OverviewandSchedule BrownsFerryNuclearPlantFlowInducedVibration(FIV)

MonitoringProgram Questions/Comments G.Doyle G.Doyle P.Donahue G.Doyle l 2

BFN EPU - Overview and Schedule Browns Ferry EPU License Amendment Request FIV Monitoring Program l 3 New consolidated Browns Ferry Nuclear Plant (BFN)

Extended Power Uprate (EPU) License Amendment Request (LAR) submittal SupersedespreviousBFNEPUsubmittals AddressescurrentBFNconditionsandlicensingbasis(e.g.,AREVA ATRIUM10XMfueltype)

UsestheformatofRS001,ReviewStandardforExtendedPower Uprates AddressespreviousapplicableNRCRequestsforAdditional Information(RAIs)

Appliesimprovedsubmittalverificationprocesstoensure completenessandaccuracy WeareheretopresentanddiscussourFlowInducedVibration MonitoringProgram VibrationMonitoringProgramisconsistentwithexistingguidance Includesdiscussionsonmonitoringscopeandacceptancecriteria

BFN EPU - Overview and Schedule Browns Ferry EPU License Amendment Request FIV Monitoring Program l 4

BFN EPU - FIV Monitoring Program Browns Ferry EPU License Amendment Request FIV Monitoring Program

Background

VibrationlevelsoftheMainSteam(MS)andFeedwater (FW)pipingareexpectedto increasebyapproximately35%basedonflowincreasesofupto16%

Otherpossiblesourcesofincreasedvibration,suchasflowinstabilitiesoracoustic resonanceasaresultofincreasedflowvelocities,maycontributetoEPUvibration levels AcousticvibrationsuppressorshavebeeninstalledontheMSsystemattheBFNunitsto reducevibrationsusceptibilityofpipingandcomponents FlowratesinportionsoftheCondensate(CD),ExtractionSteam(ES)andHeaterDrains (HD)systemsincreasesimilarlytoMSandFW,andaresusceptibletoincreased vibrationatEPUconditions Confirmatorytestprogramwillbeimplementedtomonitorpipingandattached componentvibrationlevelsduringinitialpowerascensiontoEPUconditions VibrationstudiesassociatedwithSteamDryerreplacement,includingeffectsofReactor RecirculationPumpvanepassingfrequencieswillbeaddressedaspartofSteamDryer vibrationmonitoring l 5

Browns Ferry EPU License Amendment Request FIV Monitoring Program PreviousVibrationMonitoring

  • VibrationlevelsatCurrentLicensedThermalPower(CLTP)(3458MWt)were obtainedaspartoftheBFNUnit1restartin2007
  • AdditionalCLTPvibrationdatawascollectedin2008,forBFNUnit1MSand FWpipingandcomponents
  • Thesetestsprovidedvibrationinformationthatledtotheinstallationof AcousticVibrationSuppressors(AVS)onBFNUnits1,2,and3
  • BFNUnit1CLTPvibrationmonitoringresultsarepartofthebasisforthe vibrationmonitoringthatwillbeperformedduringEPUpowerascensionfor BFNUnits1,2,and3 l 6 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program PreviousVibrationMonitoring(continued)

  • MSandFWPipingLocationSelection
  • HydraulicandstructuralmodelsoftheMSandFWpipingwerecreatedfor determinationofthevibrationmonitoringlocationsanddevelopmentofthe vibrationacceptancecriteria
  • Thevibrationmonitoringlocationswereselectedbasedonthestructural timehistoryanalysisresults,wheresignificantdisplacementsoccurred relativetootherlocations
  • Themeasurementlocationswerealsoselectedsuchthatthegeneraloverall pipingresponsewouldbereflectedinthedataanditwouldnotbelikely thatsignificantvibrationswouldbemissed l 7 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program PreviousVibrationMonitoring(continued)

  • AcceptanceCriteriaDevelopment
  • Allowabledisplacementandaccelerationlimitsattheselectedmeasurement locationswerecalculatedbasedontheanalysisresultsandAmericanSociety ofMechanicalEngineers(ASME)codefatiguestresslimitsforsteadystate vibrationconsistentwithASMEOMS/G,Part3(OM3)
  • Theprimaryacceptancecriteriaareintermsofdisplacement,whichis directlyproportionaltopipestress
  • Secondaryacceptancecriteriaintermsofaccelerationweredeterminedfor locationswhereaccelerometersareusedformonitoring l 8 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program PreviousVibrationMonitoring(continued)

  • AcceptanceCriteriaDevelopment
  • ThedisplacementlimitsforMSandFWareapplicableforvibration frequenciesupto50Hz,whichcorrespondstothefrequencyrangeinwhich themostsignificantstructuraldisplacementresponsesareexpected
  • Pipingdisplacementsduetoexcitationfrequenciesabove50Hzaretypically insignificantrelativetothelowerfrequencydisplacements
  • SecondaryaccelerationlimitsestablishedfortheFWpipinginside containmentarealsoapplicableforfrequenciesupto50Hz,sincesignificant forcingfrequenciesandstructuralresponsesabove50Hzarenotexpectedin theFWsystem
  • AcceptanceCriteriausedduringpreviousvibrationmonitoringtobeapplied toEPUvibrationmonitoring l 9 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program OperatingExperience

  • NEDO33159,ExtendedPowerUprateLessonsLearnedandRecommendations
  • SignificantEventReport(SER)206,OperatingExperience(OE)22641atQuad CitiesandrecentNRCfinding(Dresden)- MainSteamReliefValve(MSRV) failuresrelatedtovibration
  • InstituteofNuclearPowerOperations(INPO)Report1322FeedRegulator ValveFailure-AirsupplylinefailureduetohighvibrationatWaterford
  • INPOReport1281SteamBypassControlValveFailures-Vibrationrelated SteamBypassControlSystemfailuresatStLucie
  • BFNcomponentspecificevaluationsbasedonOE-FatigueandWear
  • MSRVs-TargetRockSolenoidValvesandPilotAssemblies,Temperature Elements
  • MS,HPCI,RCICValveOperatorsandLimitSwitches l 10 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program l 11 EPUVibrationMonitoring

  • MSandFWMonitoringScope
  • InsideContainmentMSandFW
  • MSPiping:7monitoringlocations,12measurements (1or2directionsperlocation)
  • FWPiping:9monitoringlocations,14measurements (1or2directionsperlocation)
  • MSComponents:8monitoringlocations,24measurements (3directionsperlocation)
  • OutsideContainmentMSandFW
  • MSpiping:11monitoringlocations,20measurements (1to3directionsperlocation)
  • FWpiping:13monitoringlocations,23measurements (1or2directionsperlocation)

BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program l 12 EPUVibrationMonitoring(continued)

  • ComponentMonitoringScope
  • BFNoperatinghistoryindicatesthatexcessivecomponentvibrations shouldbenotexpectedatEPUconditions
  • Inordertoprovideconfirmationthatcomponentvibrationswillbe withinacceptablelimitsatEPUconditions,selectedcomponentswill beinstrumentedwithaccelerometers
  • Theselectedcomponentsinclude:
  • Foursafetyreliefvalves(SRV)
  • Onemainsteamisolationvalve(MSIV)
  • InboardisolationvalvefortheMSdrainpiping
  • Inboardisolationvalveforthereactorcoreisolationcooling(RCIC) turbinesteamsupplyline
  • Inboardisolationvalveforthehighpressurecoolantinjection(HPCI) turbinesteamsupplyline BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program l 13 EPUVibrationMonitoring(continued)

  • BalanceofPlant(BOP)SystemsMonitoringScope
  • CondensateSystem
  • TheCDpipingbetweenthe3rd stagefeedwater heatersandthe reactorfeedwater pumps(RFPs)aswellastheCDpipingbetween the4th stagefeedwater heatersandthe3rd stagefeedwater heaters wereselectedforEPUvibrationmonitoring
  • ExtractionSteamSystem
  • TheESpipingfromthehighpressure(HP)turbinetothe1st stage feedwater heatersandtheESpipingfromthelowpressure(LP) turbinetothe2nd stagefeedwater heaterswasselectedforEPU vibrationmonitoring
  • HeaterDrainsSystem
  • TheHDsystembetweenthe1st and2nd stagefeedwater heatersand betweenthe2nd and3rd stagefeedwater wasselectedforEPU vibrationmonitoring BFN EPU - FIV Monitoring Program

EPUVibrationMonitoring(continued)

  • SmallBorePipingSusceptibilityEvaluation
  • Considerations
  • Thepresenceorabsenceofatiebacksupport
  • Theroutingandsupportconfigurationsofthesmallborelines
  • Lineswithunsupportedconcentratedmassesorlong,unsupportedruns
  • Theexpectedamplitudesoftheheadervibrations
  • Smallborelinesincludedinthelargeborepipingmodels
  • Thetimehistoryanalysisresultsareusedtodeterminethesusceptibilityof thesmallborelinestotheheaderinducedvibrations
  • Potentiallysusceptibleconfigurationswillbeidentifiedandaddressed
  • Anynecessarymodificationsidentifiedintheanalysiswillbemade priortoEPUpowerascension
  • Previousstudiesidentified10locationsforEPUmonitoringstudies
  • AdditionallocationsforEPUmonitoringmaybeidentifiedasaresultofthe susceptibilityevaluation Browns Ferry EPU License Amendment Request FIV Monitoring Program l 14 BFN EPU - FIV Monitoring Program

Browns Ferry EPU License Amendment Request FIV Monitoring Program Conclusions

  • ReviewofpreviousvibrationdatacollectedduringBFNUnit1restartpower ascensiontestingindicatesCLTPvibrationlevelswellwithinacceptablelimits
  • ExtrapolationoftheCLTPdatatoEPUpowerlevelsindicatesthatvibrationof pipingandcomponentswillnotbeadverselyaffectedbyEPUoperation
  • Pipingandattachedcomponentsonsystemsexperiencingsignificantflow increasesasaresultofEPUwillbeincludedinthevibrationmonitoring program
  • PipingvibrationacceptancecriteriaisbasedonASMEOM3
  • Componentvibrationacceptancecriteriaisbasedoncomponentspecific dynamiccharacteristicsandindustryexperience
  • Smallborepipingassessmentswillbeperformedtoidentifypotentially susceptibleconfigurations,andanymodificationsrequiredtoreducevibration susceptibilitywillbemadepriortoEPUpowerascension l 15 BFN EPU - FIV Monitoring Program

BFN EPU - Acronym List Browns Ferry EPU License Amendment Request FIV Monitoring Program l 16 ASME-AmericanSocietyofMechanical Engineers AVS-AcousticVibrationSuppressors BFN-BrownsFerryNuclearPlant BOP-BalanceofPlant CD-Condensate CLTP-CurrentLicensedThermalPower EPU-ExtendedPowerUprate ES-ExtractionSteam FW-Feedwater HD-HeaterDrains HP-HighPressure HPCI-HighPressureCoolantInjection Hz-Hertz INPO-InstituteofNuclearPower Operations LAR-LicenseAmendmentRequest LP-LowPressure MS-MainSteam MSIV-MainSteamIsolationValve MSRV-MainSteamReliefValve MWt - MegawattThermal NRC-NuclearRegulatoryCommission OE-OperatingExperience OLTP-OriginalLicensedThermalPower RAI-RequestforAdditionalInformation RCIC-ReactorCoreIsolationCooling RFP-ReactorFeedwater Pump SER-SignificantEventReport SRV-SafetyReliefValve

BFN EPU - Questions/Comments Browns Ferry EPU License Amendment Request FIV Monitoring Program l 17