SBK-L-14083, 2013 Annual Radioactive Effluent Release Report

From kanterella
(Redirected from ML14121A399)
Jump to navigation Jump to search
2013 Annual Radioactive Effluent Release Report
ML14121A399
Person / Time
Site: Seabrook 
Issue date: 04/28/2014
From: Ossing M
NextEra Energy Seabrook
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SBK-L-14083
Download: ML14121A399 (58)


Text

NEXTera ENERGYPV.

,,,ABROK April 28, 2014 Docket No. 50-443 SBK-L-14083 U.S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001 Seabrook Station 2013 Annual Radioactive Effluent Release Report Pursuant to 1 OCFR 50.36a (a).2 and Technical Specification 6.8.1.4, NextEra Energy Seabrook, LLC submits the Annual Radioactive Effluent Release Report for 2013. Pursuant to Technical Specification 6.13.c, a copy of the Offsite Dose Calculation Manual (ODCM) is not being provided with this submittal as there were no changes made to the ODCM in 2013.

The following information is provided in the enclosures:

Effluent release data as required by Regulatory Guide 1.21 Joint frequency distributions of wind speed, wind direction, and atmospheric stability Radiation dose assessment Should you have any questions regarding Department Manager, at (603) 773-7496.

this letter, please contact David Robinson, Chemistry Sincerely, NextEra Energy Seabrook, LLC M'ichael n

sing Licensing Manag/*

NextEra Energy Seabrook, LLC, P.O. Box 300, Lafayette Road, Seabrook, NH 03874

U.S. Nuclear Regulatory Commission SBK-L-14083/ Page 2 cc:

NRC Region I Administrator NRC Project Manager, Project Directorate 1-2 NRC Senior Resident Inspector Seth Breitmaier, American Nuclear Insurers Effluent Release Data as Required by Regulatory Guide 1.21

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Supplemental Information 2013 Facility:

Seabrook Station Unit 1 Licensee: NextEra Energy Seabrook, LLC

1.

Regulatory Limits A.

Gaseous Effluents

a.

5.0 mnrad per quarter gamma air dose.

b.

10.0 mrad per quarter beta air dose.

c.

7.5 mrem per quarter to any organ.

B.

Liquid Effluents

a.

1.5 mrem per quarter total body.

b.

5.0 mrem per quarter any organ.

c.

2.0 E-04 ptCi/ml dissolved or entrained gas.

2.

Effluent Concentration Limits Provide the ECL's used in determining allowable release rates or concentrations.

a.

Fission and activation gases: 10 ECL

b.

lodines: 10 ECL

c.

Particulates, half-lives >8 days: 10 ECL

d.

Liquid Effluents: 10 ECL

3.

Average Energy Not applicable

4.

Measurements and Approximations of Total Radioactivity Provide the methods used to measure or approximate the total radioactivity in effluents and the methods used to determine radionuclide composition.

A.

Fission and activation gases: Determined by gamma spectroscopy. Total error is based on stack flow error, analytical error, and calculated sampling error.

B.

lodines: Determined by collection on charcoal with subsequent gamma spectroscopy analysis. Total error is based on stack flow error, analytical error, and calculated sampling error.

C.

Particulates: Determined by collection on fixed filter with subsequent gamma spectroscopy analysis.

Strontium is determined by composite analysis of filters by liquid scintillation, gross alpha by proportional counter and iron 55 by liquid scintillation. Total error is based on stack flow error, analytical error, and calculated sampling error.

D.

Liquid Effluents: Determined by gamma spectroscopy.

A composite sample is analyzed for strontium by liquid scintillation, tritium by liquid scintillation, gross alpha by proportional counter and iron 55 by liquid scintillation.

Total error is based on the volume discharge error and analytical error.

E.

ND: None Detected or No Detectable Activity

5. Batch Releases Provide the following information relating to batch releases of radioactive materials in liquid and gaseous effluents.

A.

Liquid

a.

Number of batch releases: 73

b.

Total time for batch releases: 18245 minutes

c.

Maximum time period for batch release: 1028 minutes

d.

Average time period for batch release: 250 minutes

e.

Minimum time period for batch release: 60 minutes

f.

Average stream flow during periods of release of effluents into a flowing stream: 1.67 E+06 liters per minute B.

Gaseous

a.

Number of batch releases: 25

b.

Total time for batch releases: 3535 minutes

c.

Maximum time period for batch release: 1703 minutes

d.

Average time period for batch release: 199 minutes

e.

Minimum time period for batch release: 3 minute

6.

Abnormal Releases A.

Liquid

a.

Number of releases: 0

b.

Total activity released: N/A B.

Gaseous

a.

Number of releases: 0

b.

Total activity released: N/A

TABLE 1A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES Unit Quarter Qure urer Quarter Est. Total 1

Qu2e Qur3 4

Eror %

A. Fission and activation aases

1. Total releases Ci 1.__

Total re s3.57E-03 3.12E-02 7.41E-03 4.08E-02 1.70E+01

2. Average release rate uCi/sec for period 4.59E-04 3.97E-03 9.32E-04 5.13E-03
3. Percent of applicable Technical Specification limit 1.02E-04 9.64E-05 2.12E-04 9.74E-04
13. lodines (Note 1)
1. Total release Ci ND ND ND ND 1.50E0
2. Average release rate uCi/sec for period N/A N/A N/A N/A
3. Percent of applicable Technical Specification limit 2.73E-01 1.73E-01 4.00E-01 1.96E-01 C. Particulates
1. Total release Ci 2.19E+00 3.06E+00 3.36E+00 3.90E+00 1.80E+01
2. Average release rate uCssec for period 2.77E-01 3.88E-01 4.25E-01 4.94E-01
3. Percent of applicable Technical Specification limit 2.73E-01 1.73E-01 4.00E-01 1.96E-01
4. Total alpha radioactivity Ci ND ND ND ND D. Tritium
1. Total release Ci 2.05E+01 1.27E+01 2.91E+01 1.34E+01 1.60E+01
2. Average release rate for period uCi/sec 2.64E+00 1.62E+00 3.66E+00 1.69E+00
3. Percent of applicable Technical Specification 1

limit II 2.73E-01 1.73E-01 4.00E-01 1.96E-01

TABLE 1B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 GASEOUS EFFLUENTS-ELEVATED RELEASES CONTINUOUS Nuclides Released Unit Quarter Quarter Quarter Quarter I1 1 1 2

3 I

4

1.

Fission and activation gases argon-41 Ci ND ND ND ND krypton-85 Ci ND ND ND ND krypton-85m Ci ND ND ND ND krypton-87 Ci ND ND ND ND krypton-88 Ci ND ND ND ND xenon-131rm Ci ND ND ND ND xenon-1 33 Ci ND ND ND ND xenon-133m Ci ND ND ND ND xenon-1 35 Ci ND ND ND ND xenon-1 35m Ci ND ND ND ND xenon-138 Ci ND ND ND ND Ci Ci unidentified Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00

2.

Iodines (Note 1) iodine-1 31 Ci ND ND ND ND iodine-1 33 Ci ND ND ND ND iodine-1 35 Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00

3.

Particulates strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-1 34 Ci ND ND ND ND cesium-1 37 Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND cobalt-58 Ci ND ND ND ND cobalt-60 Ci ND ND ND ND chromium-51 Ci ND ND ND ND manganese-54 Ci ND ND ND ND niobium-95 Ci ND ND ND ND iron-59 Ci ND ND ND ND carbon-14 Ci 2.19E+00 3.06E+00 3.36E+00 3.90E+00 unidentified Ci ND ND ND ND Total for period Ci 2.19E+00 3.06E+00 3.36E+00 3.90E+00

TABLE 1B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 GASEOUS EFFLUENTS-ELEVATED RELEASES BATCH Nuclides Released Unit Quarter Quarter Quarter Quarter

1.

Fission and activation gases argon-41 Ci 3.57E-03 3.12E-03 7.41E-03 4.08E-02 krypton-85 Ci ND ND ND ND krypton-85m Ci ND ND ND ND krypton-87 Ci ND ND ND ND krypton-88 Ci ND ND ND ND xenon-131m Ci ND ND ND ND xenon-133 Ci ND ND ND ND xenon-133m Ci ND ND ND ND xenon-1 35 Ci ND ND ND ND xenon-135m Ci ND ND ND ND xenon-138 Ci ND ND ND ND Ci unidentified Ci ND ND ND ND Total for period Ci 3.57E-03 3.12E-03 7.41E-03 4.08E-02

2.

Iodines iodine-131 Ci ND ND ND ND ibdine-133 Ci ND ND ND ND iodine-1 35 Ci ND ND ND ND Total for period Ci 0.00E+00 O.OOE+00 O.OOE+00 Q.OOE+00

3.

Particulates strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-134 Ci ND ND ND ND cesium-1 37 Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND Ci unidentified Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00

TABLE 2A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES I

Unit Quarter 1 Quarter 2 Quarter 3 Quarter 4 Err.ora%

A. Fission and activation products

1. Total releases Ci 9.64E-04 6.07E-04 8.92E-04 1.67E-04 6.00E+00
2. Average diluted concentration uCi/ml 1.51E-12 9.45E-13 1.56E-12 2.38E-13 durina oeriod
3. Percent of applicable limit 2.97E-04 1.01E-03 6.27E-04 3.37E-03 B. Tritium
1. Total release ci 1.29E+02 3.96E+01 1.73E+01 1.77E+02 8.00E+00 du.AvringDediutd conenraio

_______.______1_

Average diluted concentration uCi/ml 2.02E-07 6.17E-08 3.02E-08 2.52E-07 durina period

3. Percent of applicable limit 1.50E-03 3.68E-04 2.40E-04 2.08E-03 C. Dissolved and entrained gases
1. Total release ci ND ND ND ND 1.90E+01
2. Average diluted concentration uci/mi N/A N/A N/A N/A during period
3. Percent of applicable limit N/A N/A N/A N/A D. Gross alpha radioactivity
1. Total release ci ND ND ND ND I1.OOE+01

TABLE 2B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 LIQUID EFFLUENTS CONTINUOUS MODE Nuclides Released Unit Quarter 1 Quarter 2 Quarter 3 Quarter 4 strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-134 Ci ND ND ND ND cesium-137 Ci ND ND ND ND iodine-131 Ci ND ND ND ND iodine-133 Ci ND ND ND ND cobalt-57 Ci ND ND ND ND cobalt-58 Ci ND 1.03E-05 ND ND cobalt-60 Ci ND ND ND ND iron-55 Ci ND ND ND ND iron-59 Ci ND ND ND ND zinc-65 Ci ND ND ND ND manganese-54 Ci ND ND ND ND chromium-51 Ci ND ND ND ND zirconium-niobium-95 Ci ND ND ND ND molybdenum-99 Ci ND ND ND ND technetium-99m Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND cerium-141 Ci ND ND ND ND unidentified Ci ND ND ND ND

[

Total for period(above)

Ci O.OOE+oo I 1.03E-05 O.OOE+00 0

O.OOE+OO ]

xenon-1 31 m Ci ND ND ND ND xenon-1 33m Ci ND ND ND ND xenon-133 Ci N_ D ND ND ND xenon-135 Ci ND ND ND ND

TABLE 2B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 LIQUID EFFLUENTS BATCH MODE Nuclides Released Unit Quarter 1 Quarter 2 Quarter 3 Quarter 4 strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-1 34 Ci ND ND ND ND cesium-1 37 Ci ND ND ND 6.08E-06 iodine-131 Ci ND ND ND ND iodine-1 33 Ci ND ND ND ND cobalt-57 Ci ND ND ND ND cobalt-58 Ci 3.63E-04 1.70E-04 1.03E-04 4.81 E-05 cobalt-60 Ci 2.86E-05 1.21 E-05 ND 2.52E-05 chromium-51 Ci ND ND ND ND iron-55 Ci ND ND ND ND iron-59 Ci ND ND ND ND zinc-65 Ci ND ND ND ND manganese-54 Ci 1.40E-06 ND 3.33E-06 ND zirconium-niobium-95 Ci ND ND ND ND molybdenum-99 Ci ND ND ND ND technetium-99m Ci ND ND ND ND silver-11Orn Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND cerium-141 Ci ND ND ND ND antimony-122 Ci ND ND ND ND antimony-124 Ci 7.49E-06 ND ND ND antimony-125 Ci 5.64E-04 4.14E-04 7.87E-04 8.77E-05 antimony-126 Ci ND ND ND ND niobium-97 Ci ND ND ND ND tin-117m Ci ND ND ND ND sodium-24 Ci ND ND ND ND Tellurium-129m Ci ND ND ND ND Tellurium-132 Ci ND ND ND ND unidentified Ci ND ND ND ND Total for period(above)

Ci 9.64E-04 5.96E-04 8.93E-04 167E-04 xenon-133 Cic ND ND I

ND ND xenon-I 35 Ci ND ND ND ND

TABLE iC EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 GASEOUS EFFLUENTS-GROUND LEVEL RELEASES CONTINUOUS Nuclides Released Ut Quarter Quarter Quarter Quarter Nulie Reeae Uni 1

2 34

1. Fission and activation gases argon-41 Ci ND ND ND ND krypton-85 Ci ND ND ND ND krypton-85m Ci ND ND ND ND krypton-87 Ci ND ND ND ND krypton-88 Ci ND ND ND ND xenon-133 Ci ND ND ND ND xenon-135 Ci ND ND ND ND xenon-135m Ci ND ND ND ND xenon-138 Ci ND ND ND ND Ci Ci unidentified Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 0.00E+OO
2.

Iodines (Note 1) iodine-131 Ci ND ND ND ND iodine-1 33 Ci ND ND ND ND Ci Total for period Ci 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00

3.

Particulates strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-1 34 Ci ND ND ND ND cesium-1 36 Ci ND ND ND ND cesium-137 Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND cobalt-58 Ci ND ND ND ND cobalt-60 Ci ND ND ND ND chromium-51 Ci ND ND ND ND unidentified Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 0.00E+OQ

TABLE iC EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 GASEOUS EFFLUENTS-GROUND LEVEL RELEASES BATCH Nuclides Released Unit Quaer Quarter Quarter Quarter I

I1 1 1 2

3 4

1.

Fission and activation gases argon-41 Ci ND ND ND ND krypton-85 Ci ND ND ND ND krypton-85m Ci ND ND ND ND krypton-87 Ci ND ND ND ND krypton-88 Ci ND ND ND ND xenon-131m Ci ND ND ND ND xenon-133m Ci ND ND ND ND xenon-133 Ci ND ND ND ND xenon-135 Ci ND ND ND ND xenon-1 35m Ci ND ND ND ND xenon-138 Ci ND ND ND ND Ci Ci unidentified Ci ND ND ND ND Total for period Ci Q.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00

2.

Iodines iodine-131 Ci ND ND ND ND iodine-132 Ci ND ND ND ND iodine-133 Ci ND ND ND ND iodine-135 Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00

3.

Particulates strontium-89 Ci ND ND ND ND strontium-90 Ci ND ND ND ND cesium-1 34 Ci ND ND ND ND cesium-1 36 Ci ND ND ND ND cesium-137 Ci ND ND ND ND barium-lanthanum-140 Ci ND ND ND ND cobalt-57 Ci ND ND ND ND cobalt-58 Ci ND ND ND ND cobalt-60 Ci ND ND ND ND manganese-54 Ci ND ND ND ND iron-59 Ci ND ND ND ND niobium/zirconium-95 Ci ND ND ND ND chromium-51 Ci ND ND ND ND technetium-99m Ci ND ND ND ND bromine-82 Ci ND ND ND ND unidentified Ci ND ND ND ND Total for period Ci O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)

1.

Type of waste Uni1t year Est. Total tPeriod Error, %

a.

Spent resins, filter sludges, evaporator mN Bottoms, etc.

Ci N/A N/A

b.

Dry compressible waste, contaminated 6.93E+01 Equip, etc.

Ci 3.76E+00

c.

Irradiated components, control mN/A N/A Rods, etc.

Ci

d.

Other (describe) 3 Ci.N/A N/A

2.

Estimate of major nuclide composition (by type of waste)

a.

N/A I% 1 N/A b.

C.

d.

Ni-63 4.65E+O1 Fe-55 3.87E+O1 Co-60 1.26E+O1 Co-58 1.28E+00 Sb-125 3.43E-01 Mn-54 2.24E-01 Nb-94 1.49E-0 1 H-3 8.67E-02 Cs-137 8.13E-02 Co-57 3.94E-02 Nb-95 3.58E-03 Cm-243 1.78E-03 N/A I%I N/A N/A I%I N/A

3.

Solid Waste Disposition Number of Shipments 5

Waste Class Container Type A

General Design A

General Design A

General Design Solidification Agent N/A N/A N/A Mode of Transportation Truck Truck Truck Destination Duratek, Oak Ridge, TN Duratek, Kingston, TN EnergySolutions, Clive, UT

B. IRRADIATED FUEL SHIPMENTS (Disposition)

Number of Shipments Mode of Transportation N/A N/A Destination N/A C. REVIEW AND APPROVAL Prepared By:

Reviewed By:

AnnrovedBv: :

's C

Z Date:

Date:

Date:

4'

-1191-/

IFf

List of Appendices Appendix Title A

Offsite Dose Calculation Manual B

Process Control Program C

Liquid Holdup Tanks D

Radwaste Treatment Systems E

Unplanned Releases

Appendix A Offsite Dose Calculation Manual Requirement: Technical Specification 6.13.2c requires that licensee initiated changes to the Offsite Dose Calculation Manual be submitted to the Commission in the Annual Radioactive Effluent Release Report for the period in which the change(s) was made effective. Include in this changes to the Radiological Environmental Program in accordance with Offsite Dose Calculation Manual (ODCM) - C.9.1.l and - C.9.2.1.

Response

No changes were made to the ODCM in 2013.

Appendix B Process Control Program Requirement: The Offsite Dose Calculation Manual requires that licensee initiated changes to the Process Control Program be submitted to the Commission in the Annual Radioactive Effluent Release Report for the period in which the change(s) was made.

Response

No changes were made to the process control program in 2013.

Appendix C Liquid Holdup Tanks Requirement: Technical Specification 3.11.1.4 limits the quantity of radioactive material contained in any outside temporary tank. With the quantity of radioactive material in any outside temporary tank exceeding the limits of Technical Specification 3.11.1.4, a description of the events leading to this condition is required in the next Annual Effluent Release Report in accordance with Tech. Spec. 6.8.1.4.

Response

From January 1,2013 to December 31, 2013, there was no radioactive material stored in any temporary outdoor tank that exceeded the limits of T. S. 3.11.1.4.

ADpendix D Radwaste Treatment Systems Requirement: Technical Specification 6.14. la requires that licensee initiated changes to the Radwaste Treatment Systems (liquid, gaseous, and solid) be submitted to the Commission in the Annual Radioactive Effluent Release Report for the period in which the change was made.

Response

For 2013 FPL Energy Seabrook LLC, will submit any changes to the Radwaste Treatment Systems (liquid, gaseous and solid) as part of the FSAR update.

Appendix E Unplanned Releases Requirement: Technical Specification 6.8.1.4 requires a list and description of unplanned releases from the site to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents made during the reporting period.

Submit all groundwater monitoring well sample results and a description of any significant onsite leaks/spills that impact groundwater

Response

A review of the January 1, 2013 to December 31, 2013 time period indicated there were no unplanned, unanticipated or abnormal releases from the site to unrestricted areas of radioactive materials of gaseous or liquid effluents. See next sheet for groundwater monitoring well results.

2013 Ground Water Monitoring Well Tritium Data Date/Time BD-1 BD-2 BD-3 BD-4 BD-5 BD-6 BU-1 SC-1 SD-1 SD-2 SD-3 SD-4 SD-5 SU-1 SW-1 SW-2 SW-3 SW-4 SW-5 SW-6 SU-10 SU-11 BU-10 BU-11 TW-1 TW-2 TW-3 Spring / Summer'2013 Sam plin 03/21/13 1480 5520 03/22/13

<563

<532 03/27/13 2580 05/01/13 1330

<554

<554 05/02/13

<553

<554

<553 05/03/13 1780

<544

<544 05/06/13

<549

<546 05/08/13

<538

<540

<539

<537 05/30/13

<548

<546 05/31/13

<518

<525

<507

<591 06/05/13

<537

<536

<537 07/12/13 1

<545

<547 07118/13

<552 Fall / Winter 2013 Sampling--

09/17/13 1

<564 09/18/13 969 1120 2100 09/19/13

<565

<564

<563

<563

<563 09125/13

<593

<587

<591 1 <586

<587

<543 3030 09/26/13

<542

<541

<541

<526 09127113 2840 12/04/13

<547 12/20/13

_2770 12/27/13

<533

<533 12/30/13 672 1040 NA Paired well locations:

SD-1 / BD-2 South of plant near seawall inside PA fence SD-2 / BD-3 East of plant inside owner controlled area SD-3 / BD-4 Northeast of plant inside owner controlled area SD-4 / BD-5 Southwest of plant, south of cooling tower inside owner controlled area SD-5 / BD-6 South of Unit 2 containment equipment hatch outside PA fence SU-1 / BU-1 Northwest of plant (Background location) inside owner controlled area SU-10 / BU-10 North / northwest of plant inside PA fence SU-1 1 / BU-1 I North of plant inside PA fence Selected well locations:

SW-1 South of Fuel Storage Building (Indicator location) inside PA fence SW-2 East of plant near Service Water Pump House inside PA fence SW-3 Southwest of plant near Unit 1 to Unit 2 tunnel inside PA fence SW-4 South of waste process building / steam generator blowdown room inside PA fence SW-5 West of service water building inside PA fence SW-6 Southwest of demineralized tank 259 inside PA fence TW-1 Southeast of plant inside owner controlled area outside PA fence TW-2 Southeast of plant inside owner controlled area outside PA fence TW-3 Southeast of plant inside owner controlled area outside PA fence Note: All sample results in pCi/L Definitions:

S = Shallow C = Cross gradient B = Bedrock D = down gradient U = up gradient T = temporary W = well Joint Frequency Distributions of Wind Speed, Wind Direction, and Atmospheric Stability

SEABROOK JAI13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS A CLASS FREQUENCY (PERCENT)

=

6.29 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 0

0 2

0 1

1 0

2 1

1 0

0 0

1 0

0 0

9 (1)

.00

.00

.37

.00

.19

.19

.00

.37

.19

.19

.00

.00

.00

.19

.00

.00

.00 1.69 (2)

.00

.00

.02

.00

.01

.01

.00

.02

.01

.01

.00

.00

.00

.01

.00

.00

.00

.11 4-7 1

2 1

1 11 5

9 4

5 7

10 16 22 11 7

0 0

112 (1)

.19

.37

.19

.19 2.06

.94 1.69

.75

.94 1.31 1.87 3.00 4.12 2.06 1.31

.00

.00 20.97 (2)

.01

.02

.01

.01

.13

.06

.11

.05

.06

.08

.12

.19

.26

.13

.08

.00

.00 1.32 8-12 1

1 2

10 40 29 62 5

12 17 37 27 51 23 9

0 0

326 (1)

.19

.19

.37 1.87 7.49 5.43 11.61

.94 2.25 3.18 6.93 5.06 9.55 4.31 1.69

.00

.00 61.05 (2)

.01

.01

.02

.12

.47

.34

.73

.06

.14

.20

.44

.32

.60

.27

.11

.00

.00 3.84 13-18 0

0 3

7 6

6 9

0 5

6 9

4 10 13 4

0 0

82 (1)

.00

.00

.56 1.31 1.12 1.12 1.69

.00

.94 1.12 1.69

.75 1.87 2.43

.75

.00

.00 15.36 (2)

.00

.00

.04

.08

.07

.07

.11

.00

.06

.07

.11

.05

.12

.15

.05

.00

.00

.97 19-24 0

0 0

0 0

0 0

0 0

1 1

0 1

1 0

0 0

4 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.19

.19

.00

.19

.19

.00

.00

.00

.75 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01

.01

.00

.01

.01

.00

.00

.00

.05 GT 24 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0

0 0

1 (1)

.00

.00

.00

.00

.19

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.19 (2)

.00

.00

.00

.00

.01

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01 ALL SPEEDS 2

3 8

18 59 41 80 11 23 32 57 47 84 49 20 0

0 534 (1)

.37

.56 1.50 3.37 11.05 7.68 14.98 2.06 4.31 5.99 10.67 8.80 15.73 9.18 3.75

.00

.00 100.00 (2)

.02

.04

.09

.21

.70

.48

.94

.13

.27

.38

.67

.55

.99

.58

.24

.00

.00 6.29 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS B CLASS FREQUENCY (PERCENT)

=

4.03 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 0

0 0

1 2

0 0

2 1

0 1

0 1

0 0

2 0

10 (1)

.00

.00

.00

.29

.58

.00

.00

.58

.29

.00

.29

.00

.29

.00

.00

.58

.00 2.92 (2)

.00

.00

.00

.01

.02

.00

.00

.02

.01

.00

.01

.00

.01

.00

.00

.02

.00

.12 4-7 1

0 1

4 18 4

4 0

1 3

2 13 15 12 3

4 0

85 (1)

.29

.00

.29 1.17 5.26 1.17 1.17

.00

.29

.88

.58 3.80 4.39 3.51

.88 1.17

.00 24.85 (2)

.01

.00

.01

.05

.21

.05

.05

.00

.01

.04

.02

.15

.18

.14

.04

.05

.00 1.00 8-12 2

0 3

14 27 11 11 1

2 7

13 21 19 26 22 5

0 184 (1)

.58

.00

.88 4.09 7.89 3.22 3.22

.29

.58 2.05 3.80 6.14 5.56 7.60 6.43 1.46

.00 53.80 (2)

.02

.00

.04

.16

.32

.13

.13

.01

.02

.08

.15

.25

.22

.31

.26

.06

.00 2.17 13-18 0

0 3

2 0

0 0

0 0

0 4

1 12 17 16 2

0 57 (1)

.00

.00

.88

.58

.00

.00

.00

.00

.00

.00 1.17

.29 3.51 4.97 4.68

.58

.00 16.67 (2)

.00

.00

.04

.02

.00

.00

.00

.00

.00

.00

.05

.01

.14

.20

.19

.02

.00

.67 19-24 0

0 0

0 0

1 0

0 0

0 0

0 0

3 2

0 0

6 (1)

.00

.00

.00

.00

.00

.29

.00

.00

.00

.00

.00

.00

.00

.88

.58

.00

.00 1.75 (2)

.00

.00

.00

.00

.00

.01

.00

.00

.00

.00

.00

.00

.00

.04

.02

.00

.00

.07 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 ALL SPEEDS 3

0 7

21 47 16 15 3

4 10 20 35 47 58 43 13 0

342 (1)

.88

.00 2.05 6.14 13.74 4.68 4.39

.88 1.17 2.92 5.85 10.23 13.74 16.96 12.57 3.80

.00 100.00 (2)

.04

.00

.08

.25

.55

.19

.18

.04

.05

.12

.24

.41

.55

.68

.51

.15

.00 4.03 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS C CLASS FREQTUENCY (PERCENT)

=

5.03 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.O0

.00 C-3 0

0 1

0 3

0 0

1 1

0 0

0 1

0 2

0 0

9 (1)

.00

.00

.23

.00

.70

.00

.00

.23

.23

.00

.00

.00

.23

.00

.47

.00

.00 2.11 (2)

.00

.00

.01

.00

.04

.00

.00

.01

.01

.00

.00

.00

.01

.00

.02

.00

.00

.11 4-7 7

3 3

10 18 6

6 2

2 5

7 8

12 17 9

9 0

124 (1) 1.64

.70

.70 2.34 4.22 1.41 1.41

.47

.47 1.17 1.64 1.87 2.81 3.98 2.11 2.11

.00 29.04 (2)

.08

.04

.04

.12

.21

.07

.07

.02

.02

.06

.08

.09

.14

.20

.11

.11

.00 1.46 8-12 5

3 9

16 21 4

10 2

2 8

13 21 19 30 36 4

0 203 (1) 1.17

.70 2.11 3.75 4.92

.94 2.34

.47

.47 1.87 3.04 4.92 4.45 7.03 8.43

.94

.00 47.54 (2)

.06

.04

.11

.19

.25

.05

.12

.02

.02

.09

.15

.25

.22

.35

.42

.05

.00 2.39 13-18 0

0 2

2 3

0 0

0 1

1 6

3 11 31 21 0

0 81 (1)

.00

.00

.47

.47

.70

.00

.00

.00

.23

.23 1.41

.70 2.58 7.26 4.92

.00

.00 18.97 (2)

.00

.00

.02

.02

.04

.00

.00

.00

.01

.01

.07

.04

.13

.37

.25

.00

.00

.95 19-24 0

0 0

0 0

0 0

0 0

0 1

1 2

2 1

0 0

7 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.23

.23

.47

.47

.23

.00

.00 1.64 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01

.01

.02

.02

.01

.00

.00

.08 GT 24 0

0 0

0 3

0 0

0 0

0 0

0 0

0 0

0 0

3 (1)

.00

.00

.00

.00

.70

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.70 (2)

.00

.00

.00

.00

.04

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.04 ALL SPEEDS 12 6

15 28 48 10 16 5

6 14 27 33 45 80 69 13 0

427 (1) 2.81 1.41 3.51 6.56 11.24 2.34 3.75 1.17 1.41 3.28 6.32 7.73 10.54 18.74 16.16 3.04

.00 100.00 (2)

.14

.07

.18

.33

.57

.12

.19

.06

.07

.16

.32

.39

.53

.94

.81

.15

.00 5.03 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JANI3-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS D CLASS FREQUENCY (PERCENT)

=

48.42 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

1 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.02

.00

.00

.00

.00

.02 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01

.00

.00

.00

.00

.01 C-3 30 30 22 19 11 10 13 10 24 14 20 23 32 34 24 18 0

354 (1)

.73

.73

.54

.46

.27

.24

.32

.24

.58

.34

.49

.56

.78

.83

.58

.92

.00 8.62 (2)

.35

.35

.26

.22

.13

.12

.15

.12

.28

.16

.24

.27

.38

.40

.28

.45

.00 4.17 4-7 56 50 69 107 139 54 65 87 60 94 120 162 186 218 183 121 0

1771 (1) 1.36 1.22 1.68 2.60 3.38 1.31 1.58 2.12 1.46 2.29 2.92 3.94 4.53 5.31 4.45 2.94

.00 43.10 (2)

.66

.59

.81 1.26 1.64

.64

.77 1.03

.71 1.11 1.41 1.91 2.19 2.57 2.16 1.43

.00 20.87 8-12 30 25 81 59 62 19 24 31 27 73 147 117 157 273 199 65 0

1389 (1)

.73

.61 1.97 1.44 1.51

.46

.58

.75

.66 1.78 3.58 2.85 3.82 6.64 4.84 1.58

.00 33.80 (2)

.35

.29

.95

.70

.73

.22

.28

.37

.32

.86 1.73 1.38 1.85 3.22 2.34

.77

.00 16.37 13-18 2

8 59 26 19 1

2 5

6 24 18 14 46 151 88 13 0

482 (1)

.05

.19 1.44

.63

.46

.02

.05

.12

.15

.58

.44

.34 1.12 3.67 2.14

.32

.00 11.73 (2)

.02

.09

.70

.31

.22

.01

.02

.06

.07

.28

.21

.16

.54 1.78 1.04

.15

.00 5.68 19-24 3

1 12 9

14 0

0 0

0 4

2 1

5 34 2

3 0

90 (1)

.07

.02

.29

.22

.34

.00

.00

.00

.00

.10

.05

.02

.12

.83

.05

.07

.00 2.19 (2)

.04

.01

.14

.11

.16

.00

.00

.00

.00

.05

.02

.01

.06

.40

.02

.04

.00 1.06 GT 24 0

0 4

4 9

0 0

0 0

1 0

0 0

4 0

0 0

22 (1)

.00

.00

.10

.10

.22

.00

.00

.00

.00

.02

.00

.00

.00

.10

.00

.00

.00

.54 (2)

.00

.00

.05

.05

.11

.00

.00

.00

.00

.01

.00

.00

.00

.05

.00

.00

.00

.26 ALL SPEEDS 121 114 247 224 254 84 104 133 117 210 307 317 427 714 496 240 0

4109 (1) 2.94 2.77 6.01 5.45 6.18 2.04 2.53 3.24 2.85 5.11 7.47 7.71 10.39 17.38 12.07 5.84

.00 100.00 (2) 1.43 1.34 2.91 2.64 2.99

.99 1.23 1.57 1.38 2.47 3.62 3.74 5.03 8.41 5.84 2.83

.00 48.42 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS E CLASS FREQUENCY (PERCENT)

=

22.05 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW N4W NNW VRBL TOTAL MPH CALM 1

2 1

0 0

0 0

0 0

0 0

1 1

2 1

2 0

11 (1)

.05

.11

.05

.00

.00

.00

.00

.00

.00

.00

.00

.05

.05

.11

.05

.11

.00

.59 (2)

.01

.02

.01

.00

.00

.00

.00

.00

.00

.00

.00

.01

.01

.02

.01

.02

.00

.13 C-3 22 14 19 22 17 12 18 13 27 31 39 50 81 48 45 27 0

485 (1) 1.18

.75 1.02 1.18

.91

.64

.96

.69 1.44 1.66 2.08 2.67 4.33 2.57 2.41 1.44

.00 25.92 (2)

.26

.16

.22

.26

.20

.14

.21

.15

.32

.37

.46

.59

.95

.57

.53

.32

.00 5.71 4-7 21 16 8

10 37 15 46 36 42 74 142 279 192 131 87 25 0

1161 (1) 1.12

.86

.43

.53 1.98

.80 2.46 1.92 2.24 3.96 7.59 14.91 10.26 7.00 4.65 1.34

.00 62.05 (2)

.25

.19

.09

.12

.44

.18

.54

.42

.49

.87 1.67 3.29 2.26 1.54 1.03

.29

.00 13.68 8-12 17 3

2 0

6 3

2 6

3 17 26 48 16 28 8

1 0

186 (1)

.91

.16

.11

.00

.32

.16

.11

.32

.16

.91 1.39 2.57

.86 1.50

.43

.05

.00 9.94 (2)

.20

.04

.02

.00

.07

.04

.02

.07

.04

.20

.31

.57

.19

.33

.09

.01

.00 2.19 13-18 1

0 0

1 4

0 0

0 2

5 2

1 0

1 0

0 0

17 (1)

.05

.00

.00

.05

.21

.00

.00

.00

.11

.27

.11

.05

.00

.05

.00

.00

.00

.91 (2)

.01

.00

.00

.01

.05

.00

.00

.00

.02

.06

.02

.01

.00

.01

.00

.00

.00

.20 19-24 0

0 0

4 0

0 0

0 1

3 0

0 0

0 0

0 0

8 (1)

.00

.00

.00

.21

.00

.00

.00

.00

.05

.16

.00

.00

.00

.00

.00

.00

.00

.43 (2)

.00

.00

.00

.05

.00

.00

.00

.00

.01

.04

.00

.00

.00

.00

.00

.00

.00

.09 GT 24 0

0 0

0 3

0 0

0 0

0 0

0 0

0 0

0 0

3 (1)

.00

.00

.00

.00

.16

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.16 (2)

.00

.00

.00

.00

.04

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.04 ALL SPEEDS 62 35 30 37 67 30 66 55 75 130 209 379 290 210 141 55 0

1871 (1) 3.31 1.87 1.60 1.98 3.58 1.60 3.53 2.94 4.01 6.95 11.17 20.26 15.50 11.22 7.54 2.94

.00 100.00 (2)

.73

.41

.35

.44

.79

.35

.78

.65

.88 1.53 2.46 4.47 3.42 2.47 1.66

.65

.00 22.05 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS F CLASS FREQUENCY (PERCENT)

=

7.78 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 2

0 1

1 0

1 0

0 0

0 0

1 2

1 2

0 0

11 (1)

.30

.00

.15

.15

.00

.15

.00

.00

.00

.00

.00

.15

.30

.15

.30

.00

.00 1.67 (2)

.02

.00

.01

.01

.00

.01

.00

.00

.00

.00

.00

.01

.02

.01

.02

.00

.00

.13 C-3 11 8

9 20 6

6 3

1 5

25 28 54 75 84 41 25 0

401 (1) 1.67 1.21 1.36 3.03

.91

.91

.45

.15

.76 3.79 4.24 8.18 11.36 12.73 6.21 3.79

.00 60.76 (2)

.13

.09

.11

  • .24

.07

.07

.04

.01

.06

.29

.33

.64

.88

.99

.48

.29

.00 4.72 4-7 4

2 0

0 5

2 0

1 2

3 20 69 39 40 48 12 0

247 (1)

.61

.30

.00

.00

.76

.30

.00

.15

.30

.45 3.03 10.45 5.91 6.06 7.27 1.82

.00 37.42 (2)

.05

.02

.00

.00

.06

.02

.00

.01

.02

.04

.24

.81

.46

.47

.57

.14

.00 2.91 8-12 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0

1 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.15

.00

.00

.15 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01

.00

.00

.01 13-18 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 19-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 ALL SPEEDS 17 10 10 21 11 9

3 2

7 28 48 124 116 125 92 37 0

660 (1) 2.58 1.52 1.52 3.18 1.67 1.36

.45

.30 1.06 4.24 7.27 18.79 17.58 18.94 13.94 5.61

.00 100.00 (2)

.20

.12

.12

.25

.13

.11

.04

.02

.08

.33

.57 1.46 1.37 1.47 1.08

.44

.00 7.78 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS G CLASS FREQUENCY (PERCENT)

=

6.41 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNTW NW NNW VRBL TOTAL MPH CALM 1

1 0

0 0

0 0

0 0

0 0

1 3

2 0

0 0

8 (1)

.18

.18

.00

.00

.00

.00

.00

.00

.00

.00

.00

.18

.55

.37

.00

.00

.00 1.47 (2)

.01

.01

.00

.00

.00

.00

.00

.00

.00

.00

.00

.01

.04

.02

.00

.00

.00

.09 C-3 4

6 8

10 0

2 0

0 4

2 27 63 159 127 38 9

0 459 (1)

.74 1.10 1.47 1.84

.00

.37

.00

.00

.74

.37 4.96 11.58 29.23 23.35 6.99 1.65

.00 84.38 (2)

.05

.07

.09

.12

.00

.02

.00

.00

.05

.02

.32

.74 1.87 1.50

.45

.11

.00 5.41 4-7 0

1 0

0 1

0 0

0 0

2 6

12 11 24 18 2

0 77 (1)

.00

.18

.00

.00

.18

.00

.00

.00

.00

.37 1.10 2.21 2.02 4.41 3.31

.37

.00 14.15 (2)

.00

.01

.00

.00

.01

.00

.00

.00

.00

.02

.07

.14

.13

.28

.21

.02

.00

.91 8-12 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 13-18 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 19-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 ALL SPEEDS 5

8 8

10 1

2 0

0 4

4 33 76 173 153 56 11 0

544 (1)

.92 1.47 1.47 1.84

.18

.37

.00

.00

.74

.74 6.07 13.97 31.80 28.13 10.29 2.02

.00 100.00 (2)

.06

.09

.09

.12

.01

.02

.00

.00

.05

.05

.39

.90 2.04 1.80

.66

.13

.00 6.41 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 43.0 FT WIND DATA STABILITY CLASS ALL CLASS FREQUENCY (PERCENT)

= 100.00 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 4

3 2

1 0

1 0

0 0

0 0

3 7

5 3

2 0

31 (1)

.05

.04

.02

.01

.00

.01

.00

.00

.00

.00

.00

.04

.08

.06

.04

.02

.00

.37 (2)

.05

.04

.02

.01

.00

.01

.00

.00

.00

.00

.00

.04

.08

.06

.04

.02

.00

.37 C-3 67 5B 61 72 40 31 34 29 63 73 115 190 349 294 150 101 0

1727 (1)

.79

.68

.72

.85

.47

.37

.40

.34

.74

.86 1.36 2.24 4.11 3.46 1.77 1.19

.00 20.35 (2)

.79

.68

.72

.85

.47

.37

.40

.34

.74

.86 1.36 2.24 4.11 3.46 1.77 1.19

.00 20.35 4-7 90 74 82 132 229 86 130 130 112 188 307 559 477 453 355 173 0

3577 (1) 1.06

.87

.97 1.56 2.70 1.01 1.53 1.53 1.32 2.22 3.62 6.59 5.62 5.34 4.18 2.04

.00 42.15 (2) 1.06

.87

.97 1.56 2.70 1.01 1.53 1.53 1.32 2.22 3.62 6.59 5.62 5.34 4.18 2.04

.00 42.15 8-12 55 32 97 99 156 66 109 45 46 122 236 234 262 380 275 75 0

2289 (1)

.65

.38 1.14 1.17 1.84

.78 1.28

.53

.54 1.44 2.78 2.76 3.09 4.48 3.24

.8B

.00 26.97 (2)

.65

.38 1.14 1.17 1.84

.78 1.28

.53

.54 1.44 2.78 2.76 3.09 4.48 3.24

.86

.00 26.97 13-1P 3

8 67 38 32 7

11 5

14 36 39 23 79 213 129 15 0

719 (1)

.04

.09

.79

.45

.38

.08

.13

.06

.16

.42

.46

.27

.93 2.51 1.52

.18

.00 8.47 (2)

.04

.09

.79

.45

.38

.08

.13

.06

.16

.42

.46

.27

.93 2.51 1.52

.18

.00 8.47 19-24 3

1 12 13 14 1

0 0

1 8

4 2

8 40 5

3 0

115 (1)

.04

.01

.14

.15

.16

.01

.00

.00

.01

.09

.05

.02

.09

.47

.06

.04

.00 1.36 (2)

.04

.01

.14

.15

.16

.01

.00

.00

.01

.09

.05

.02

.09

.47

.06

.04

.00 1.36 GT 24 0

0 4

4 16 0

0 0

0 1

0 0

0 4

0 0

0 29 (1)

.00

.00

.05

.05

.19

.00

.00

.00

.00

.01

.00

.00

.00

.05

.00

.00

.00

.34 (2)

.00

.00

.05

.05

.19

.00

.00

.00

.00

.01

.00

.00

.00

.05

.00

.00

.00

.34 ALL SPEEDS 222 176 325 359 487 192 284 209 236 428 701 1011 1182 1389 917 369 0

8487 (1) 2.62 2.07 3.83 4.23 5.74 2.26 3.35 2.46 2.78 5.04 8.26 11.91 13.93 16.37 10.80 4.35

.00 100.00 (2) 2.62 2.07 3.83 4.23 5.74 2.26 3.35 2.46 2.78 5.04 8.26 11.92 13.93 16.37 10.80 4.35

.00 100.00 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS A CLASS FREQUENCY (PERCENT)

=

6.41 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 1

1 0

1 1

0 0

2 0

1 1

0 0

0 0

0 0

8 (1)

.19

.19

.00

.19

.19

.00

.00

.37

.00

.19

.19

.00

.00

.00

.00

.00

.00 1.50 (2)

.01

.01

.00

.01

.01

.00

.00

.02

.00

.01

.01

.00

.00

.00

.00

.00

.00

.10 4-7 1

0 2

2 7

5 4

0 3

3 2

3 6

2 4

0 0

44 (1)

.19

.00

.37

.37 1.31

.94

.75

.00

.56

.56

.37

.56 1.12

.37

.75

.00

.00 8.24 (2)

.01

.00

.02

.02

.08

.06

.05

.00

.04

.04

.02

.04

.07

.02

.05

.00

.00

.53 8-12 0

1 1

8 26 24 48 4

6 11 22 22 50 12 7

1 0

243 (1)

.00

.19

.19 1.50 4.87 4.49 8.99

.75 1.12 2.06 4.12 4.12 9.36 2.25 1.31

.19

.00 45.51 (2)

.00

.01

.01

.10

.31

.29

.58

.05

.07

.13

.26

.26

.60

.14

.08

.01

.00 2.92 13-18 1

1 4

7 7

6 28 12 9

10 27 17 30 22 6

0 0

187 (1)

.19

.19

.75 1.31 1.31 1.12 5.24 2.25 1.69 1.87 5.06 3.18 5.62 4.12 1.12

.00

.00 35.02 (2)

.01

.01

.05

.08

.08

.07

.34

.14

.11

.12

.32

.20

.36

.26

.07

.00

.00 2.25 19-24 0

0 2

1 2

1 6

1 2

3 4

3 11 5

2 0

0 43 (1)

.00

.00

.37

.19

.37

.19 1.12

.19

.37

.56

.75

.56 2.06

.94

.37

.00

.00 8.05 (2)

.00

.00

.02

.01

.02

.01

.07

.01

.02

.04

.05

.04

.13

.06

.02

.00

.00

.52 GT 24 0

0 0

0 1

0 1

0 0

1 1

0 4

1 0

0 0

9 (1)

.00

.00

.00

.00

.19

.00

.19

.00

.00

.19

.19

.00

.75

.19

.00

.00

.00 1.69 (2)

.00

.00

.00

.00

.01

.00

.01

.00

.00

.01

.01

.00

.05

.01

.00

.00

.00

.11 ALL SPEEDS 3

3 9

19 44 36 87 19 20 29 57 45 101 42 19 1

0 534 (1)

.56

.56 1.69 3.56 8.24 6.74 16.29 3.56 3.75 5.43 10.67 8.43 18.91 7.87 3.56

.19

.00 100.00 (2)

.04

.04

.11

.23

.53

.43 1.04

.23

.24

.35

.68

.54 1.21

.50

.23

.03

.00 6.41 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DECT3 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS B CLASS FREQUENCY (PERCENT)

=

4.06 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 0

0 1

1 0

0 0

0 0

1 2

0 1

0 1

0 0

7 (1)

.00

.00

.30

.30

.00

.00

.00

.00

.00

.30

.59

.00

.30

.00

.30

.00

.00 2.07 (2)

.00

.00

.01

.01

.00

.00

.00

.00

.00

.01

.02

.00

.01

.00

.01

.00

.00

.08 4-7 2

0 0

3 10 3

5 0

0 2

0 5

5 5

4 1

0 45 (1)

.59

.00

.00

.89 2.96

.89 1.48

.00

.00

.59

.00 1.48 1.48 1.48 1.18

.30

.00 13.31 (2)

.02

.00

.00

.04

.12

.04

.06

.00

.00

.02

.00

.06

.06

.06

.05

.01

.00

.54 8-12 1

1 2

15 21 19 8

1 2

4 9

14 22 17 12 7

0 155 (1)

.30

.30

.59 4.44 6.21 5.62 2.37

.30

.59 1.18 2.66 4.14 6.51 5.03 3.55 2.07

.00 45.86 (2)

.01

.01

.02

.18

.25

.23

.10

.01

.02

.05

.11

.17

.26

.20

.14

.08

.00 1.86 13-18 0

0 5

4 1

0 4

2 2

4 5

7 11 30 17 3

0 95 (1)

.00

.00 1.48 1.18

.30

.00 1.18

.59

.59 1.18 1.48 2.07 3.25 8.88 5.03

.89

.00 28.11 (2)

.00

.00

.06

.05

.01

.00

.05

.02

.02

.05

.06

.08

.13

.36

.20

.04

.00 1.14 19-24 0

0 0

0 0

1 0

0 0

0 3

1 10 8

8 0

0 31 (1)

.00

.00

.00

.00

.00

.30

.00

.00

.00

.00

.89

.30 2.96 2.37 2.37

.00

.00 9.17 (2)

.00

.00

.00

.00

.00

.01

.00

.00

.00

.00

.04

.01

.12

.10

.10

.00

.00

.37 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 2

3 0

0 0

5 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.59

.89

.00

.00

.00 1.48 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.02

.04

.00

.00

.00

.06 ALL SPEEDS 3

1 8

23 32 23 17 3

4 11 19 27 51 63 42 11 0

338 (1)

.89

.30 2.37 6.80 9.47 6.80 5.03

.89 1.18 3.25 5.62 7.99 15.09 18.64 12.43 3.25

.00 100.00 (2)

.04

.01

.10

.28

.38

.28

.20

.04

.05

.13

.23

.32

.61

.76

.50

.13

.00 4.06 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAI13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS C CLASS FREQUENCY (PERCENT)

=

4.98 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WMW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 1

1 0

0 0

1 1

0 0

0 0

0 1

1 1

0 0

7 (1)

.24

.24

.00

.00

.00

.24

.24

.00

.00

.00

.00

.00

.24

.24

.24

.00

.00 1.69 (2)

.01

.01

.00

.00

.00

.01

.01

.00

.00

.00

.00

.00

.01

.01

.01

.00

.00

.08 4-7 2

1 3

3 9

8 3

2 3

1 4

5 4

7

  • 6 5

0 66 (1)

.48

.24

.72

.72 2.17 1.93

.72

.48

.72

.24

.96 1.20

.96 1.69 1.45 1.20

.00 15.90 (2)

.02

.01

.04

.04

.11

.10

.04

.02

.04

.01

.05

.06

.05

.08

.07

.06

.00

.79 8-12 11 0

10 15 6

18 11 5

2 5

6 11 17 17 18 4

0 156 (1) 2.65

.00 2.41 3.61 1.45 4.34 2.65 1.20

.48 1.20 1.45 2.65 4.10 4.10 4.34

.96

.00 37.59 (2)

.13

.00

.12

.16

.07

.22

.13

.06

.02

.06

.07

.13

.20

.20

.22

.05

.00 1.87 13-18 1

3 7

5 3

0 3

1 2

3 10 8

20 38 26 1

0 131 (1)

.24

.72 1.69 1.20

.72

.00

.72

.24

.48

.72 2.41 1.93 4.82 9.16 6.27

.24

.00 31.57 (2)

.01

.04

.08

.06

.04

.00

.04

.01

.02

.04

.12

.10

.24

.46

.31

.01

.00 1.57 19-24 0

0 0

0 0

0 0

0 1

1 3

3 9

22 7

0 0

46 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.24

.24

.72

.72 2.17 5.30 1.69

.00

.00 11.08 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.01

.01

.04

.04

.11

.26

.08

.00

.00

.55 GT 24 0

0 0

0 3

0 0

0 0

0 0

1 2

2 1

0 0

9 (1)

.00

.00

.00

.00

.72

.00

.00

.00

.00

.00

.00

.24

.48

.48

.24

.00

.00 2.17 (2)

.00

.00

.00

.00

.04

.00

.00

.00

.00

.00

.00

.01

.02

.02

.01

.00

.00

.11 ALL SPEEDS 15 5

20 23 21 27 18 8

8 10 23 28 53 87 59 10 0

415 (1) 3.61 1.20 4.82 5.54 5.06 6.51 4.34 1.93 1.93 2.41 5.54 6.75 12.77 20.96 14.22 2.41

.00 100.00 (2)

.18

.06

.24

.28

.25

.32

.22

.10

.10

.12

.28

.34

.64 1.04

.71

.12

.00 4.98 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAI13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS D CLASS FREQUENCY (PERCENT)

=

48.81 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 12 9

8 9

7 6

11 4

9 3

7 4

9 6

4 16 0

124 (1)

.30

.22

.20

.22

.17

.15

.27

.10

.22

.07

.17

.10

.22

.15

.10

.39

.00 3.05 (2)

.14

.11

.10

.11

.08

.07

.13

.05

.11

.04

.08

.05

.11

.07

.05

.19

.00 1.49 4-7 58 49 53 69 75 68 44 29 32 45 41 48 63 73 91 68 0

906 (1) 1.43 1.21 1.30 1.70 1.85 1.67 1.08

.71

.79 1.11 1.01 1.18 1.55 1.80 2.24 1.67

.00 22.29 (2)

.70

.59

.64

.83

.90

.82

.53

.35

.38

.54

.49

.58

.76

.88 1.09

.82

.00 10.88 8-12 83 37 61 67 39 54 48 77 50 95 123 128 130 211 164 83 0

1450 (1) 2.04

.91 1.50 1.65

.96 1.33 1.18 1.89 1.23 2.34 3.03 3.15 3.20 5.19 4.03 2.04

.00 35.67 (2) 1.00

.44

.73

.80

.47

.65

.58

.92

.60 1.14 1.48 1.54 1.56 2.53 1.97 1.00

.00 17.41 13-18 40 20 65 21 12 8

5 23 26 56 95 91 145 263 146 39 0

1055 (1)

.98

.49 1.60

.52

.30

.20

.12

.57

.64 1.38 2.34 2.24 3.57 6.47 3.59

.96

.00 25.95 (2)

.48

.24

.78

.25

.14

.10

.06

.28

.31

.67 1.14 1.09 1.74 3.16 1.75

.47

.00 12.67 19-24 3

14 27 17 23 1

1 6

6 16 17 9

59 138 53 11 0

401 (1)

.07

.34

.66

.42

.57

.02

.02

.15

.15

.39

.42

.22 1.45 3.39 1.30

.27

.00 9.86 (2)

.04

.17

.32

.20

.28

.01

.01

.07

.07

.19

.20

.11

.71 1.66

.64

.13

.00 4.81 GT 24 5

5 18 14 18 0

3 0

0 4

3 0

11 42 3

3 0

129 (1)

.12

.12

.44

.34

.44

.00

.07

.00

.00

.10

.07

.00

.27 1.03

.07

.07

.00 3.17 (2)

.06

.06

.22

.17

.22

.00

.04

.00

.00

.05

.04

.00

.13

.50

.04

.04

.00 1.55 ALL SPEEDS 201 134 232 197 174 137 112 139 123 219 286 280 417 733 461 220 0

4065 (1) 4.94 3.30 5.71 4.85 4.28 3.37 2.76 3.42 3.03 5.39 7.04 6.89 10.26 18.03 11.34 5.41

.00 100.00 (2) 2.41 1.61 2.79 2.37 2.09 1.64 1.34 1.67 1.48 2.63 3.43 3.36 5.01 8.80 5.53 2.64

.00 48.81 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS E CLASS FREQUENCY (PERCENT)

=

21.60 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW 1

NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 1

0 0

0 0

0 0

1 0

2 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.06

.00

.00

.00

.00

.00

.00

.06

.00

.11 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.01

.00

.00

.00

.00

.00

.00

.01

.00

.02 C-3 6

3 10 1

3 13 9

8 10 11 4

6 8

8 2

7 0

109 (1)

.33

.17

.56

.06

.17

.72

.50

.44

.56

.61

.22

.33

.44

.44

.11

.39

.00 6.06 (2)

.07

.04

.12

.01

.04

.16

.11

.10

.12

.13

.05

.07

.10

.10

.02

.08

.00 1.31 4-7 13 8

12 10 21 26 27 27 37 27 26 22 19 18 16 19 0

328 (1)

.72

.44

.67

.56 1.17 1.45 1.50 1.50 2.06 1.50 1.45 1.22 1.06 1.00

.89 1.06

.00 18.23 (2)

.16

.10

.14

.12

.25

.31

.32

.32

.44

.32

.31

.26

.23

.22

.19

.23

.00 3.94 8-12 40 17 5

9 5

3 23 47 48 73 118 167 123 134 63 40 0

915 (1) 2.22

.94

.28

.50

.28

.17 1.28 2.61 2.67 4.06 6.56 9.28 6.84 7.45 3.50 2.22

.00 50.86 (2)

.48

.20

.06

.11

.06

.04

.28

.56

.58

.88 1.42 2.01 1.48 1.61

.76

.48

.00 10.99 13-18 20 6

2 1

2 3

1 12 7

22 44 101 93 79 16 8

0 417 (1) 1.11

.33

.11

.06

.11

.17

.06

.67

.39 1.22 2.45 5.61 5.17 4.39

.89

.44

.00 23.18 (2)

.24

.07

.02

.01

.02

.04

.01

.14

.08

.26

.53 1.21 1.12

.95

.19

.10

.00 5.01 19-24 2

2 0

1 1

0 2

0 1

3 1

0 0

1 0

0 0

14 (1)

.11

.11

.00

.06

.06

.00

.11

.00

.06

.17

.06

.00

.00

.06

.00

.00

.00

.7B (2)

.02

.02

.00

.01

.01

.00

.02

.00

.01

.04

.01

.00

.00

.01

.00

.00

.00

.17 GT 24 0

0 0

4 5

0 0

0 2

3 0

0 0

0 0

0 0

14 (1)

.00

.00

.00

.22

.28

.00

.00

.00

.11

.17

.00

.00

.00

.00

.00

.00

.00

.78 (2)

.00

.00

.00

.05

.06

.00

.00

.00

.02

.04

.00

.00

.00

.00

.00

.00

.00

.17 ALL SPEEDS 81 36 29 26 37 45 62 94 106 139 193 296 243 240 97 75 0

1799 (1) 4.50 2.00 1.61 1.45 2.06 2.50 3.45 5.23 5.89 7.73 10.73 16.45 13.51 13.34 5.39 4.17

.00 100.00 (2)

.97

.43

.35

.31

.44

.54

.74 1.13 1.27 1.67 2.32 3.55 2.92 2.88 1.16

.90

.00 21.60 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS F CLASS FREQUENCY (PERCENT)

=

7.78 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 1

0 0

0 0

0 0

0 0

1 0

0 0

0 0

2 (1)

.00

.00

.15

.00

.00

.00

.00

.00

.00

.00

.00

.15

.00

.00

.00

.00

.00

.31 (2)

.00

.00

.01

.00

.00

.00

.00

.00

.00

.00

.00

.01

.00

.00

.00

.00

.00

.02 C-3 4

6 4

4 6

4 3

3 2

3 5

3 2

2 0

3 0

54 (1)

.62

.93

.62

.62

.93

.62

.46

.46

.31

.46

.77

.46

.31

.31

.00

.46

.00 8.33 (2)

.05

.07

.05

.05

.07

.05

.04

.04

.02

.04

.06

.04

.02

.02

.00

.04

.00

.65 4-7 13 10 7

1 5

5 6

17 17 24 22 12 11 6

12 9

0 177 (1) 2.01 1.54 1.08

.15

.77

.77

.93 2.62 2.62 3.70 3.40 1.85 1.70

.93 1.85 1.39

.00 27.31 (2)

.16

.12

.08

.01

.06

.06

.07

.20

.20

.29

.26

.14

.13

.07

.14

.11

.00 2.13 8-12 13 14 2

0 1

3 3

9 12 25 42 41 42 46 29 28 0

310 (1) 2.01 2.16

.31

.00

.15

.46

.46 1.39 1.65 3.86 6.48 6.33 6.48 7.10 4.48 4.32

.00 47.84 (2)

.16

.17

.02

.00

.01

.04

.04

.11

.14

.30

.50

.49

.50

.55

.35

.34

.00 3.72 13-18 5

3 1

0 0

1 0

0 0

0 10 23 26 11 9

16 0

105 (1)

.77

.46

.15

.00

.00

.15

.00

.00

.00

.00 1.54 3.55 4.01 1.70 1.39 2.47

.00 16.20 (2)

.06

.04

.01

.00

.00

.01

.00

.00

.00

.00

.12

.28

.31

.13

.11

.19

.00 1.26 19-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 ALL SPEEDS 35 33 15 5

12 13 12 29 31 52 79 80 81 65 50 56 0

648 (1) 5.40 5.09 2.31

.77 1.85 2.01 1.85 4.48 4.78 8.02 12.19 12.35 12.50 10.03 7.72 8.64

.00 100.00 (2)

.42

.40

.18

.06

.14

.16

.14

.35

.37

.62

.95

.96

.97

.78

.60

.67

.00 7.78 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS G CLASS FREQUENCY (PERCENT)

=

6.36 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW VRBL TOTAL MPH CALM 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 C-3 4

1 2

5 1

1 1

2 5

3 3

2 7

6 3

6 0

52 (1)

.75

.19

.38

.94

.19

.19

.19

.38

.94

.57

.57

.38 1.32 1.13

.57 1.13

.00 9.81 (2)

.05

.01

.02

.06

.01

.01

.01

.02

.06

.04

.04

.02

.08

.07

.04

.07

.00

.62 4-7 7

5 8

5 2

7 6

9 20 22 26 15 18 9

12 17 0

188 (1) 1.32

.94 1.51

.94

.38 1.32 1.13 1.70 3.77 4.15 4.91 2.83 3.40 1.70 2.26 3.21

.00 35.47 (2)

.08

.06

.10

.06

.02

.08

.07

.11

.24

.26

.31

.18

.22

.11

.14

.20

.00 2.26 8-12 27 4

3 0

0 0

0 2

8 17 39 27 27 42 34 25 0

255 (1) 5.09

.75

.57

.00

.00

.00

.00

.38 1.51 3.21 7.36 5.09 5.09 7.92 6.42 4.72

.00 48.11 (2)

.32

.05

.04

.00

.00

.00

.00

.02

.10

.20

.47

.32

.32

.50

.41

.30

.00 3.06 13-18 3

1 0

0 0

0 0

0 0

0 2

6 10 3

6 4

0 35 (1)

.57

.19

.00

.00

.00

.00

.00

.00

.00

.00

.38 1.13 1.89

.57 1.13

.75

.00 6.60 (2)

.04

.01

.00

.00

.00

.00

.00

.00

.00

.00

.02

.07

.12

.04

.07

.05

.00

.42 19-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 GT 24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 (1)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 (2)

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 ALL SPEEDS 41 11 13 10 3

8 7

13 33 42 70 50 62 60 55 52 0

530 (1) 7.74 2.08 2.45 1.89

.57 1.51 1.32 2.45 6.23 7.92 13.21 9.43 11.70 11.32 10.38 9.81

.00 100.00 (2)

.49

.13

.16

.12

.04

.10

.08

.16

.40

.50

.84

.60

.74

.72

.66

.62

.00 6.36 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

SEABROOK JAN13-DEC13 MET DATA JOINT FREQUENCY DISTRIBUTION (210-FOOT TOWER) 209.0 FT WIND DATA STABILITY CLASS ALL CLASS FREQUENCY (PERCENT)

= 100.00 WIND DIRECTION FROM SPEED N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NTW NNW VRBL TOTAL MPH CALM 0

0 1

0 0

0 0

0 1

0 0

1 0

0 0

1 0

4 (1)

.00

.00

.01

.00

.00

.00

.00

.00

.01

.00

.00

.01

.00

.00

.00

.01

.00

.05 (2)

.00

.00

.01

.00

.00

.00

.00

.00

.01

.00

.00

.01

.00

.00

.00

.01

.00

.05 C-3 28 21 25 21 18 25 25 19 26 22 22 15 28 23 11 32 0

361 (1)

.34

.25

.30

.25

.22

.30

.30

.23

.31

.26

.26

.18

.34

.28

.13

.38

.00 4.33 (2)

.34

.25

.30

.25

.22

.30

.30

.23

.31

.26

.26

.18

.34

.28

.13

.38

.00 4.33 4-7 96 73 85 93 129 122 95 84 112 124 121 110 126 120 145 119 0

1754 (1) 1.15

.88 1.02 1.12 1.55 1.46 1.14 1.01 1.34 1.49 1.45 1.32 1.51 1.44 1.74 1.43

.00 21.06 (2) 1.15

.88 1.02 1.12 1.55 1.46 1.14 1.01 1.34 1.49 1.45 1.32 1.51 1.44 1.74 1.43

.00 21.06 8-12 175 74 84 114 98 121 141 145 128 230 359 410 411 479 327 188 0

3484 (1) 2.10

.89 1.01 1.37 1.18 1.45 1.69 1.74 1.54 2.76 4.31 4.92 4.93 5.75 3.93 2.26

.00 41.83 (2) 2.10

.89 1.01 1.37 1.18 1.45 1.69 1.74 1.54 2.76 4.31 4.92 4.93 5.75 3.93 2.26

.00 41.83 13-18 70 34 84 38 25 18 41 50 46 95 193 253 335 446 226 71 0

2025 (1)

.84

.41 1.01

.46

.30

.22

.49

.60

.55 1.14 2.32 3.04 4.02 5.35 2.71

.85

.00 24.31 (2)

.84

.41 1.01

.46

.30

.22

.49

.60

.55 1.14 2.32 3.04 4.02 5.35 2.71

.85

.00 24.31 19-24 5

16 29 19 26 3

9 7

10 23 28 16 89 174 70 11 0

535 (1)

.06

.19

.35

.23

.31

.04

.11

.08

.12

.28

.34

.19 1.07 2.09

.84

.13

.00 6.42 (2)

.06

.19

.35

.23

.31

.04

.11

.08

.12

.28

.34

.19 1.07 2.09

.84

.13

.00 6.42 GT 24 5

5 18 18 27 0

4 0

2 8

4 1

19 48 4

3 0

166 (1)

.06

.06

.22

.22

.32

.00

.05

.00

.02

.10

.05

.01

.23

.58

.05

.04

.00 1.99 (2)

.06

.06

.22

.22

.32

.00

.05

.00

.02

.10

.05

.01

.23

.58

.05

.04

.00 1.99 ALL SPEEDS 379 223 326 303 323 289 315 305 325 502 727 806 1008 1290 783 425 0

8329 (1) 4.55 2.68 3.91 3.64 3.88 3.47 3.78 3.66 3.90 6.03 8.73 9.68 12.10 15.49 9.40 5.10

.00 100.00 (2) 4.55 2.68 3.91 3.64 3.88 3.47 3.78 3.66 3.90 6.03 8.73 9.68 12.10 15.49 9.40 5.10

.00 100.00 (1)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PAGE (2)=PERCENT OF ALL GOOD OBSERVATIONS FOR THIS PERIOD C= CALM (WIND SPEED LESS THAN OR EQUAL TO

.95 MPH)

Radiation Dose Assessment

SEABROOK STATION RADIOLOGICAL EFFLUENT IMPACT ASSESSMENT FOR 2013 (Annual Radioactive Effluent Release Report)

Prepared for NextEra Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 by AREVA INC.

400 Donald Lynch Boulevard Marlborough, MA 01752 AREVA Document No. 47-9221705-000 Preparer:

Mark Strum, AREVA NP Advisory Engineer Reviewer:

Z' 40Pv//hf Ted Messier, ýkhEVA NP Principal Scientist Approver: ?.&4

/a z

Mark Ritkkel, AREVA NP Technical Manager

Reference:

AREVA Calculation 32-9221040-000 Date:.

/

Date:

Date: J-t 2 -14 i

sheet 1 of 17

Seabrook Station Radiological Effluent Impact Assessment For 2013 (Annual Radioactive Effluent Release Report)

I.

Summary Seabrook Technical Specification Sections 6.7.6.g.4 & 9 require that limitations be placed on the quarterly and annual doses or dose commitments to Members of the Public from radioactive materials in liquid and gaseous effluents released from the station to Unrestricted Areas at or beyond the site boundary conforming to the dose objectives of Appendix I to 10 CFR Part 50. Technical Specification 6.7.6.g.8 requires that limitations on the quarterly and annual air doses resulting from noble gases released in gaseous effluents to areas beyond the site boundary also conform to Appendix I to 10 CFR Part 50. In a similar fashion, Technical Specification 6.7.6.g. 11 requires limitations on the annual dose or dose commitment to any Member of the Public due to radioactivity and radiation from uranium fuel cycle sources conforming to the EPA Radiation Standards in 40 CFR Part 190. The following table details the above referenced effluent dose limits.

DOSE OBJECTIVE CRITERIA FOR COMPLIANCE EFFLUENT TYPE DOSE TYPE QUARTERLY LIMITS ANNUAL LIMITS LIQUIDS Total Body 1.5 mrem 3 nrem (IOCFR50, APP. I)

Max. Organ 5 mrem 10 mrem NOBLE GAS Gamma Air 5 mrad 10 mrad (IOCFR50, APP. I)

Beta Air 10 mrad 20 mrad GAS PARTICULATE (IOCFR50, APP. I)

Max. Organ 7.5 mrem 15 mrem TOTAL DOSE Total Body & organ 25 mrem (40CFRI90)

[liquids, gas, direct]

Thyroid 75 mrem Technical Specification 6.8.1.4 and the Seabrook Offsite Dose Calculation Manual (ODCM) Part A, Section 10.2, provide that the Station's Annual Radioactive Effluent Release Report include a demonstration of compliance with the above off-site dose limitations, as well as the determination of dose impacts to Members of the Public who may be associated with permitted activities inside the site boundary.

Doses resulting from actual liquid and gaseous effluents from Seabrook Station during 2013 were calculated in accordance with Method II as defined in the Station ODCM. The calculation methods follow the models in Regulatory Guide 1.109 (Reference 1). The assessments included maximum whole body doses and organ doses from all liquid releases, maximum offsite organ doses resulting from airborne Iodine, Tritium, Carbon-14 and particulate radionuclides with half-lives greater than eight days, and maximum offsite beta air and gamna air doses from airborne noble gases. Calculated dose impacts from airborne effluents included atmospheric dispersion estimates utilizing concurrent meteorology recorded by the Station's on-site meteorological tower. In addition, the potential direct dose from fixed radiation AREVA Doc.# 47-9221705-000 I

sources from both plant operations and dry fuel storage were evaluated as part of the assessment required under 40 CFR Part 190 for doses fromn the uranium fuel cycle.

Doses were also calculated for the special receptor locations (per the ODCM) inside the site boundary where the public might be granted access for recreational or educational purposes. The Science and Nature Center is located in the southwest portion of the site and offers educational opportunities on nuclear power and the environment. The "Rocks" is an area northeast of the main plant facilities with access to Brown's Creek and the tidal marsh that borders the site (current public access to this location is restricted for security reasons).

All calculated liquid and gaseous pathway doses for the 2013 reporting period are well below the dose criteria of 10 CFR Part 50, Appendix 1, and the dose limits for effluent releases stated in the ODCM. In addition, the total dose to the most limiting Member of the Public due to the combined exposure to plant liquid and gaseous effluents and direct radiation from fixed plant and dry fuel storage sources was below the dose standards of 40 CFR Part 190.

2

II.

Method for Calculating the Total Body and Maximum Organ Doses Resulting from Liquid Releases Liquid waste generated during plant operations is processed and discharged to the environment via the station's circulating water cooling system. The cooling system utilizes an offshore-submerged multi-port diffuser discharge for rapid dissipation and mixing of liquid effluents in the ocean environment. A 22-port diffuser section of the discharge system is located in approximately 50 to 60 feet of water with each nozzle 7 to 10 feet above the sea floor. Eleven riser shafts, with two discharge nozzles for each diffuser, are spaced about 100 feet apart over a distance of about 1000 feet. Water is discharged in a generally eastward direction away from the shoreline through the multiport diffuser, beginning at a location over one mile offshore. During power operations, these high velocity jets passively entrain about ten volumes of fresh water into the near field jet-mixing region before the plume reaches the water surface. This arrangement also effectively prevents the discharge plume (at least to the I degree or 40 to I dilution isopleth) from impacting the shoreline over the tidal cycle.

During shutdown periods, the high velocity jet mixing created by the normal circulating water flow at the diffuser nozzles is reduced. However, mixing within the discharge tunnel water volume is significantly increased due to the long transit time for batch discharges to travel the three miles from the plant through the 19-foot diameter tunnels to the diffuser nozzles. Additional mixing of the effluent in the near field assures that an equivalent overall 10 to 1 dilution occurs by the time the effluent reaches the ocean surface.

The exposure pathways considered in the calculations of total body and maximum organ doses resulting from liquid discharges from Seabrook Station are limited to ingestion of aquatic foods and exposure to shoreline deposits. The dose calculations do not include the ingestion of potable water or irrigated vegetation as potential exposure pathways because the liquid effluents from the plant are discharged into salt water.

The dose assessment models utilized in the Offsite Dose Calculation Manual (Reference 2) are taken from Regulatory Guide 1.109 (Reference 1). The total body and organ doses are evaluated for each of the four age groups (i.e., infant, child, teen and adult) to determine the maximum total body dose and maximum organ dose via all existing exposure pathways (i.e., fish and aquatic invertebrate ingestion, and shoreline exposure) to an age-dependent individual from all detected radionuclides in plant releases. The values for the various factors considered in the model equations are provided in Regulatory Guide 1.109 and the ODCM (see Table D). The flow rate (F) of the liquid effluent and the radionuclide activities (Qi) are measured specifically prior to each liquid release. The values for half-lives for radionuclides (T 1/2) and their radioactive decay constants (Xi) have been taken from Kocher (Reference 3).

Table A presents the calculated liquid pathway doses for each calendar quarter and total for the year. The calculated annual doses as a percent of the applicable regulatory limits are shown in Table C.

The estimated quarterly and annual doses resulting from liquid effluents to members of the public are well below all dose limit criteria.

3

III.

Method for Calculating the Gamma and Beta Air Doses from Noble Gases Gamma and beta air doses due to noble gases in gaseous effluents are calculated for several receptor locations when noble gases are recorded in effluents. Those locations include the points in each of the sixteen principle compass directions of estimated highest off-site ground level air concentration of radioactive material, site boundary (or closest point on the opposite shoreline in directions which are bordered by the tidal marsh), nearest resident, nearest vegetable garden, and nearest milk animal within five miles. The special on-site receptor locations (Science and Nature Center and the "Rocks") are also included.

Atmospheric dispersion factors (i.e., X/Q factors) calculated from recorded concurrent site meteorological data (i.e., meteorological data measurements taken during the time of the release) are used in the estimation of receptor specific air concentrations due to station effluents. The atmospheric dispersion estimations utilize methodology generally consistent with US NRC Regulatory Guide I. 111 (Reference 4). Beta air doses use undepleted X/Qs and assume a semi-infinite plume at the point of exposure. Gamma air doses are calculated using the finite cloud model presented in "Meteorology and Atomic Energy - 1968" (Reference 5). That model is implemented through the definition of an effective gamma atmospheric dispersion factor [X/Q'] (Reference 6) and the replacement of the undepleted X/Q in the infinite cloud dose equation by [X/QI].

The release point of effluents is also considered in the atmospheric dispersion calculation. The primary vent stack is treated as a "mixed-mode" release, as defined in Regulatory Guide 1.111 (Reference 4). These effluents are considered to be part-time ground level / part-time elevated releases, depending on the ratio of primary vent stack exit velocity relative to the speed of prevailing wind. All other release points (e.g., Turbine Building and Chemistry lab hoods) are considered ground-level releases. The beta air and gamma air dose calculations are consistent with the models presented in Regulatory Guide 1.109 (Reference 1). The values for the dose factors, DFjI and DFi1, have been taken from Table B-I in Regulatory Guide 1.109.

Table A presents the calculated maximum off-site gamma air and beta air doses for each calendar quarter and year. The calculated annual doses as a percent of the applicable regulatory limit are shown in Table C. The estimated quarterly and annual air doses resulting from noble gas effluents are well below all dose limit criteria.

4

IV.

Method for Calculating the Critical Organ Dose Resulting from lodines, Tritium, Carbon-14 and Particulates with T 1/2 Greater than 8 Days in Gaseous Releases Regulatory Guide 1.109 (Reference 1) dose models are applied in the calculation of the critical organ doses from lodines, Tritium, Carbon-14 and particulate radionuclides released into the atmosphere during the reporting period. Atmospheric dispersion and deposition factors (i.e., depleted X/Q and D/Q factors) calculated with concurrent meteorological data (i.e., meteorological data measurements taken during the time of the release) are used in the determination of gaseous pathway doses. The dispersion models are described in Section B.7.3.2 & B.7.3.3 of the Seabrook ODCM.

Potential exposure pathways associated with gaseous effluent are (i) external irradiation from radioactivity deposited on the ground surface, (ii) inhalation, and (iii) ingestion of vegetables (both fresh leafy and stored) and milk. Dose estimates were determined for the site boundary and for the locations of the nearest resident, vegetable garden, and milk animal in each of the sixteen principle compass directions. The locations of the nearest resident, vegetable garden and milk animal in each sector were identified by the 2013 Annual Land Use Census as required by ODCM Control C.9.2.1 (see Table F).

Conservatism in the dose estimates was maintained by assuming that the vegetable garden pathway was active at each milk animal location. Milk animals were assumed to receive their entire intake from pasture during the second and third quarters. This is a conservative assumption because most dairy operations utilize supplemental feeding when animals are on pasture, or actually restrict animals to full time silage feeding throughout the entire year. Table E provides the reference sources for dose model parameter assumptions used in the dose assessment.

In June 2009, the NRC issued Revision 2 of Regulatory Guide 1.21 (Reference 7) which introduced the term "principal radionuclide" in a risk informed or dose context. A radionuclide can be considered a principal radionuclide if it contributes either (1) greater than 1 percent of the 10 CFR Part 50, Appendix I design objective dose for all radionuclides in the type of effluent being considered, or (2) greater than I percent of the activity of all radionuclides in the type of effluent being considered. In addition to natural production in the environment, Carbon-14 is also produced in nuclear reactors as a function of power output, but at amounts much less than those generated naturally or from past weapons testing. Since the time of the earlier publication of Regulatory Guide 1.21 (Revision 1) in 1974, commercial nuclear power plants have decreased total radioactive effluents (other than Carbon-14) through improved fuel performance and waste management practices to the point today that Carbon-14 could be considered a principal radionuclide under today's definition, and therefore has been included in the assessment of dose to the public from gaseous effluent releases for 2013.

The primary exposure pathways associated with Carbon-14 include inhalation and ingestion of food products that have incorporated Carbon-14 (in the form of CO2) via photosynthesis. A full year's consumption of food products are assumed to be grown from the highest impacted garden during the growing season (2 nd and 3 rd quarters). It is also assumed that the garden grows sufficient mass to support ingestion throughout the year (i.e., the annual dose to the individual is from consumption during all four quarters).

The maximum organ doses from all radionuclides in this category of gaseous effluents were determined by summing the contributions from all exposure pathways at each location, and sorting in descending 5

order. Doses were calculated for the whole body, GI-LLI, bone, liver, kidney, thyroid, lung, and skin for adults, teenagers, children, and infants. The estimated quarterly and annual organ doses at the location of the maximally exposed individual are reported in Table A.

The estimated organ doses from lodines, Tritium, Carbon-14 and Particulates in gaseous effluents are well below the 10 CFR Part 50, Appendix I dose criteria for the reporting period. (See Table C for calculated dose as a percentage of annual limits.)

6

V.

Total Dose (40 CFR Part 190) 40 CFR 190 states that the annual dose equivalent should not exceed 25 mrem to the whole body, 75 mrem to the Thyroid, or 25 mrem to any other organ of any Member of the Public from all uranium fuel cycle sources. To show compliance with this standard, the maximum doses for both the liquid and gaseous pathways from Seabrook Station are added together with the whole body dose from noble gas releases and any direct radiation component attributed to station fixed sources to the maximum receptor location. This includes the addition of spent fuel storage in a new Dry Fuel Storage (DFS) facility that began operations in July 2008 with the first transfer of spent fuel assemblies into storage arrays. A second transfer of spent fuel assemblies to the DFS occurred between August and September, 2013. The DFS facility is located on Seabrook Station property approximately 0.38 miles West-Southwest of the Unit I Containment Building. Since there are no other uranium fuel cycle facilities within five miles of Seabrook Station, no additional impacts from sources beyond Seabrook Station need be considered.

The sum of the maximum annual whole body doses to Members of the Public from all exposure pathways for liquid and gaseous effluents, plus the direct external dose from plant and dry fuel storage fixed sources, was 5.66E-02 mrem to a hypothetical individual at or beyond the site boundary. The maximum organ dose (including the thyroid) to any age group from all exposure pathways including direct radiation was 2.39E-01 mrem.

Table B illustrates the total dose projections from all station sources to the maximum potential off-site individual for the year 2013 and demonstrates compliance with the EPA's environmental radiation standard for the uranium fuel cycle per 40 CFR Part 190. (See Table C for total dose as a percentage of annual limits.)

7

VI.

References

1.

Regulatory Guide 1.109, Revision 1,"Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purposes of Evaluating Compliance with IOCFR Part 50, Appendix I", USNRC, October 1977.

2.

Seabrook Station Program Manual: Offsite Dose Calculation Manual (ODCM), Revision 36.

3.

Kocher, D.C., "Dose-Rate Conversion Factors for Exposure to Photons and Electrons", Health Physics, Vol. 45, No. 3, Sept. 1983.

4.

Regulatory Guide 1.111, Revision 1, "Method for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors",

USNRC, July 1977.

5.

Slade, D.H., "Meteorology and Atomic Energy - 1968", USAEC, July 1968.

6.

Hamawi, J.N., "AEOLUS-2 A computer Code for the Determination of Continuous and Intermittent-Release Atmospheric Dispersion and Deposition of Nuclear Power Plant Effluents in Open-Terrain Sites, Coastal Sites, and Deep-River Valleys for the Assessment of Ensuing Doses and Finite-Cloud Gamma Radiation Exposures", Entech Engineering, Inc., March 1988.

7.

Regulatory Guide 1.21, Revision 2, "Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste", USNRC, June 2009.

8

Table A Seabrook Station 2013 Annual Radioactive Effluent Release Report Maximuma) Off-Site Doses and Dose Commitments to Members of the Public Dose (mrem)(b)

Release Type I st 2nd 3rd 4th Year(c)

Quarter Quarter Quarter Quarter 2013 Liquid Effluents:

Total Body Dose 3.89E-05 1.21E-05 5.40E-06 4.86E-05 1.05E-04 (1)

(1)

(1)

(I)

Max Organ Dose 4.50E-05 1.53E-05 7.98E-06 5.OOE-05

1. 18E-04 (2)

(2)

(2)

(2)

Airborne Effluents:

Organ Dose from Carbon-14, lodines, 5.87E-02 5.99E-02 6.22E-02 5.77E-02 2.39E-01 Tritium, and Particulates (TI/2 > 8 days)

(3)

(3)

(3)

(3)

Noble Gases Beta Air 5.70E-07 3.94E-06 8.80E-07 3.29E-06 8.68E-06 (mrad)

(4)

(5)

(6)

(7)

Gamma Air 9.97E-07 7.26E-06 2.15E-06 1.44E-05 2.48E-05 (mrad)

(4)

(5)

(6)

(7)

Direct Dose Offsite From 0

Station Operation (e)

Doses (mrem) at Receptor Locations Inside Site Boundary(d):

Science and Nature Center (SW, 488m):

4.42E-06 9.15E-06 8.53E-06 5.29E-06 2.74E-05 Max Organ Dose (mrem)

The "Rocks" (NE/ENE, 244m):

2.76E-04 3.23E-04 8.3 1E-04 7.71E-04 2.20E-03 Max Organ Dose (mremr) 9

Table A (continued)

Seabrook Station 2013 Annual Radioactive Effluent Release Report Maximum(a) Off-Site Doses and Dose Commitments to Members of the Public NOTES:

(a)

"Maximum means the largest fraction of corresponding I0CFR50, Appendix I, dose design objective.

(b)

The numbered footnotes indicate the age group, organ, and location (compass sector and distance from the primary vent in meters) of the critical receptor, where appropriate, based on the most limiting radionuclide dose contributor (C-14).

(1) Adult (2) GI-LLI of an Adult (3) Bone ofachild, W 1315 m (4) ESE 2276 m (5) NNW 914 m (6) ENE 2276 m (7) E 2438 m.

(c)

"Maximum" dose for the year is the sum of the maximum doses for each quarter. This results in a conservative yearly dose estimate, but still well within the limits of 10CFR50.

(d)

For each special receptor location, the whole body and organ doses calculated for the airborne effluent releases were adjusted by the occupancy factor provided in Seabrook's ODCM (i.e.,

0.00 14 for the Science and Nature Center and 0.0076 for the "Rocks"). The most limiting on-site location with respect to dose is estimated to be the "Rocks" area.

(e)

Only station sources (both plant and dry fuel storage) are considered since there are no other fuel cycle facilities within five miles of Seabrook Station site. Dosimeter data collected in 2013 for the closest off-site environmental TLD locations in each sector (as listed in Tables B.4-1 and B.4-2 of Seabrook's ODCM) were compared to preoperational data for the same locations. No statistical difference above random background variability which could be attributed to station sources was identified.

10

Table B Seabrook Station 2013 Annual Radioactive Effluent Release Report Total Dose to Maximum Off-Site Individual (40CFRI90)

Total Body Maximum Organ(a)

Release Source (mrem)

(mrem)

Liquids 1.05E-04 1.18E-04 Noble Gases 1.65E-05 1.65E-05 Gaseous lodines, Tritium, C-14 5.65E-02 2.39E-01 Particulates (TY,2 > 8 days)

Direct Radiation 0

0 Annual Total 5.66E-02 2.39E-01 (a) Maximum organ includes consideration of the thyroid.

II

Table C Seabrook Station 2013 Annual Radioactive Effluent Release Report Maximum Doses versus ADolicable Limits C-1--lated 2013 t t Applicable ODCM Calculated Percent ODCM Annual Annual (2013) of Receptor Control Limit Dose Limit Offsite Liquid Effluents Whole Body Dose C.6.2.1 3

mrem 1.05E-04 mrem 0.0035%

Organ Dose C.6.2.1 10 mrem 1.18E-04 mrem 0.0012%

Airborne Effluents Organ Dose (iodines, H-3, C-14 and part.)

C.7.3.1 15 mrem 2.39E-01 mrem 1.59%

Gamma Air Dose (noble gases)

C.7.2.1 10 mrad 2.48E-05 mrad 0.0002%

Beta Air Dose (noble gases)

C.7.2.1 20 mrad 8.68E-06 mrad 0.00004%

All Station Sources (a)

Whole Body Dose C.8.1.1 25 mrem 5.66E-02 mrem 0.226%

Organ Dose C.8.1.1 25 mrem 2.39E-01 mrem 0.95%

Onsite (Science and Nature Center, 488m SW)

Organ Dose (iodines, H-3, C-14 and part.)

C. 7.3.1(b) 15 mrem 2.74E-05 mrem 0.00018%

Onsite (The "Rocks", 244m NE/ENE)

Organ Dose (iodines, H-3, C-14 and part.)

C. 7.3.1(b) 15 mrem 2.20E-03 mrem 0.0147%

(a) The "all station sources" doses are the sum of the whole body doses and maximum organ doses from liquid, noble gas, and gaseous iodines/tritium/carbon-14/particulate releases as well as direct radiation from fixed station sources (both plant facilities and dry fuel storage).

(b) ODCM Part A, Section 10.2 states that the annual effluent report shall include an assessment of the radiation doses from radioactive liquids and gaseous effluents to members of the public due to their activities inside the site boundary during the report period. The referenced limits (C.7.2. I & C.7.3. 1) are the acceptable doses from liquid and gaseous effluents to areas at and beyond the site boundary and are considered to be appropriate for comparison purposes.

12

Table D Seabrook Station 2013 Annual Radioactive Effluent Release Report Sources of the Values of Factors Used in Liauid Dose Eauations Factor Definition Source Uap Usage factor Table B.7-1, Station ODCM MP Mixing ratio Section B.7.1, Station ODCM (value=O.1 for aquatic foods and 0.025 for shoreline)

Bip Equilibrium bioaccumulation factor Table A-]. Reg. Guide 1.109 Daipj Dose factor Tables E-I1 through E-14, R.G. 1.109 Nuclide transit time Table E-15, Reg. Guide 1.109 Transfer coefficient from water to Reg. Guide 1.109 sediment Period of activity buildup in sediment Table B.7-2, Station ODCM tb or soil Shoreline width factor Table A-2, Reg. Guide 1.109 (value = 0.5) 13

Table E Seabrook Station 2013 Annual Radioactive Effluent Release Report Sources of Values for the Factors Used in Dose Equations for Gaseous Releases Factor Definition

£ Source tb Period of activity buildup in Table B.7-2, Station ODCM sediment or soil xi Nuclide decay constant Kocher (Reference 3)

DFGij Ground plane dose factor Table E-6, Reg. Guide 1.109 Atmospheric dispersion factor (non-IX/Q]

depleted)

Calculated following Reg. Guide 1.111

[X/Q]D Atmospheric dispersion factor (depleted)

Calculated following Reg. Guide 1.111 Ra Breathing rate Table B.7-3, Station ODCM DFAija Inhalation dose factor Tables E-7 through E-10, Reg. Guide 1.109 di Nuclide deposition rate Reg. Guide 1.109 p

Soil surface density Table B.7-2, Station ODCM Crop, leafy vegetable, or pasture Table B.7-2, Station ODCM te grass exposure period Average time from crop harvest to Table B.7-2, Station ODCM th consumption Yv Agricultural productivity by unit area Table B.7-2, Station ODCM Fraction of deposited activity r

retained on crops, leafy vegetables, Table E-15, Reg. Guide 1.109 or pasture grass Stable element transfer coefficient from soil to produce, leafy vegetable, Table E-l, Reg. Guide 1.109 or pasture grass Fractional equilibrium ratio Reg. Guide 1.109 H

Ambient absolute humidity Table B.7-2, Station ODCM 14

Table E (continued)

Seabrook Station 2013 Annual Radioactive Effluent Release Report Sources of Values for the Factors Used in Dose Eauations for Gaseous Releases Factor Definition Source Stable element transfer coefficient from feed to milk Tables E-I and E-2, Reg. Guide 1.109 tf Average time from feed to milk to Reg. Guide 1.109 consumption Fraction of the year that animals Table B.7-2, Station ODCM graze on pasture TableB.7-2,_StationODCM fs Fraction daily feed pasture grass Table B.7-2, Station ODCM Ff Stable element transfer coefficient Table E-1, Reg. Guide 1 109 from feed to meat Average time from meat animal ts slaughter to consumption Table E-15, Reg. Guide 1.109 DFlija Ingestion dose factor Tables E-I I through E-14, R.G.l.109 Annual intake of produce Table B.7-3, Station ODCM Um Annual intake of milk Table B.7-3, Station ODCM F

Ua Annual intake of meat Table B.7-3, Station ODCM Ua Annual intake of leafy vegetables Table B.7-3, Station ODCM Ingestion rate fractions for garden f9 produce Reg. Guide 1.109 f,

Ingestion rate fractions for garden Reg. Guide 1.109 leafy vegetables Reg._Guide_1.109 Rate constant for activity removal from plant and leaf surfaces by Table E-15, Reg. Guide 1.109 weathering QF Animal consumption rate Table E-3, Reg. Guide 1.109 15

Table F Seabrook Station 2013 Annual Radioactive Effluent Release Report Receptor Locations* for Seabrook Station Milk Animals Nearest Nearest within 5 Mile Resident Garden Radius Sector km (miles) km (miles) km (miles)

N NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 2.73 (1.69) 3.09 (1.92) 2.92 (1.82) 2.31 (1.44) 2.56 (1.59) 2.43 (1.51) 2.36 (1.46) 1.65 (1.02) 1.21(0.75) 1.12 (0.69) 1.13 (0.70) 1.87 (1.16) 1.32 (0.82) 1.11 (0.69) 1.22 (0.76) 1.04 (0.64) 3.97 (2.47) 3.35 (2.08) 4.20 (2.61) 2.44 (1.52) 1.25 (0.77) 1.22 (0.76) 1.72 (1.07) 4.55 (2.83) 1.55 (0.97) 1.52 (0.94) 1.27 (0.79) 1.18 (0.73) 4.52 (2.81) 6.93 (4.30)

. Locations based on 2013 Land Use Census.

16